首页 | 官方网站   微博 | 高级检索  
     

蒸压加气混凝土砌块砌体填充墙框架结构抗震性能试验
引用本文:周晓洁,,程昌恽,,杜金鹏,,陈康,,陈培奇,.蒸压加气混凝土砌块砌体填充墙框架结构抗震性能试验[J].世界地震工程,2022,38(2):046-57.
作者姓名:周晓洁    程昌恽    杜金鹏    陈康    陈培奇  
作者单位:1. 天津市土木建筑结构防护与加固重点实验室, 天津 300384;2. 天津城建大学 土木工程学院, 天津 300384
摘    要:为进一步改善框架结构平面内和平面外抗震性能,本文提出带X形斜撑的新型砌体填充墙构造方案,并进行了4榀蒸压加气混凝土砌块砌体填充墙框架结构试验,以研究墙体构造措施和墙-框连接方式对框架结构抗震性能的影响。首先进行平面内水平低周往复荷载试验,随后进行历经平面内损伤的平面外单调静力加载试验,最后进行承载力、刚度退化和耗能能力等抗震性能指标的分析。结果表明:墙-框柔性连接方案下,填充墙框架结构的平面内及平面外水平承载力和初始刚度均小于刚性连接方案,而变形能力、耗能能力和位移延性等性能指标均比刚性连接表现更好;墙-框柔性连接且填充墙带X形斜撑框架结构的平面内及平面外抗震性能指标均有明显改善,更有利于抗震。

关 键 词:砌体填充墙框架结构  X形斜撑  平面外抗震性能  试验

Seismic performance test of frame structure infilled with steaming gassed concrete masonry
ZHOU Xiaojie,' target="_blank" rel="external">,CHENG Changyun,' target="_blank" rel="external">,DU Jinpeng,' target="_blank" rel="external">,CHEN Kang,' target="_blank" rel="external">,CHEN Peiqi,' target="_blank" rel="external">.Seismic performance test of frame structure infilled with steaming gassed concrete masonry[J].World Information On Earthquake Engineering,2022,38(2):046-57.
Authors:ZHOU Xiaojie  " target="_blank">' target="_blank" rel="external">  CHENG Changyun  " target="_blank">' target="_blank" rel="external">  DU Jinpeng  " target="_blank">' target="_blank" rel="external">  CHEN Kang  " target="_blank">' target="_blank" rel="external">  CHEN Peiqi  " target="_blank">' target="_blank" rel="external">
Affiliation:1. Tianjin Key Laboratory of Civil Buildings Protection and Reinforcement, Tianjin 300384, China;2. School of Civil Engineering, Tianjin Chengjian University, Tianjin 300384, China
Abstract:In order to improve in-plane and out-of-plane seismic performance of frame structure,a new type of structural configuration of masonry infill wall with X-shaped diagonal bracing is proposed in this paper,and the test of 4 RC frames infilled with AACB(Autoclaved Aerated Concrete Blocks)was carried out aimed to study the effect of structural configuration of masonry infill wall and the way of wall-frame connection on seismic performance of frame structure. Firstly,in-plane low-cyclic reversed loading tests was conducted,and then out-of-plane monotonic static loading test about frame structure with in-plane damage was conducted;secondly,the seismic performance indicators such as carrying capacity,stiffness degradation and energy consumption capacity were analyzed according to test results. The results of test and analysis show that the horizontal carrying capacity and initial stiffness of frames with wall-frame flexible connection are both smaller than rigid connection scheme,but the seismic indicators such as deformation capacity,energy dissipation capacity and displacement ductility are better than rigid connection;comprehensive seismic performance of flexible connection frame structure including in-plane and out-of-plane behavior is the best,especially the filled wall with X-shaped diagonal bracing.
Keywords:masonry infilled frame structure  X-shaped diagonal bracing  out-of-plane seismic performance  test
点击此处可从《世界地震工程》浏览原始摘要信息
点击此处可从《世界地震工程》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号