首页 | 官方网站   微博 | 高级检索  
     

电感耦合等离子体质谱法测定地下水中锑的不确定度评定
引用本文:代阿芳,鲁立强,潘河,王苏明,王亚平,许春雪,袁建.电感耦合等离子体质谱法测定地下水中锑的不确定度评定[J].岩矿测试,2010,29(4):431-437.
作者姓名:代阿芳  鲁立强  潘河  王苏明  王亚平  许春雪  袁建
作者单位:1. 中国地质大学(武汉)材料科学与化学工程学院,湖北,武汉,430074;国家地质实验测试中心,北京,100037
2. 中国地质大学(武汉)材料科学与化学工程学院,湖北,武汉,430074
3. 黑龙江省地质矿产测试应用研究所,黑龙江,哈尔滨,150036
4. 国家地质实验测试中心,北京,100037
基金项目:国土资源部公益性行业科研专项经费资助项目 
摘    要:采用不确定度连续传递模型对电感耦合等离子体质谱法测定地下水中锑元素含量进行不确定度评定,并采用x、y的相对差,对标准曲线进行双误差回归。结果表明,水样中锑含量越低,其相对不确定度越大,且标准曲线的拟合过程引入的不确定度对其总不确定度有较大的贡献率,这与实验室中的实际测试情况相吻合。

关 键 词:电感耦合等离子体质谱法    地下水  不确定度评定  双误差回归
收稿时间:2010/5/14 0:00:00
修稿时间:2010/6/10 0:00:00

Uncertainty Evaluation for the Determination Results of Antimony in Groundwater Samples by Inductively Coupled Plasma-Mass Spectrometry
DAI A-fang,LU Li-qiang,PAN He,WANG Su-ming,WANG Ya-ping,XU Chun-xue and YUAN Jian.Uncertainty Evaluation for the Determination Results of Antimony in Groundwater Samples by Inductively Coupled Plasma-Mass Spectrometry[J].Rock and Mineral Analysis,2010,29(4):431-437.
Authors:DAI A-fang  LU Li-qiang  PAN He  WANG Su-ming  WANG Ya-ping  XU Chun-xue and YUAN Jian
Affiliation:Faculty of Material Science & Chemistry Engineering, China University of Geosciences, Wuhan 430074, China;National Research Center for Geoanalysis, Beijing 100037, China;Faculty of Material Science & Chemistry Engineering, China University of Geosciences, Wuhan 430074, China;Heilongjiang Application Institute of Geological and Mineral Analysis, Harbin 150036, China;National Research Center for Geoanalysis, Beijing 100037, China;National Research Center for Geoanalysis, Beijing 100037, China;National Research Center for Geoanalysis, Beijing 100037, China;National Research Center for Geoanalysis, Beijing 100037, China
Abstract:The measurement uncertainty for the analytical results of Sb in groundwater samples by inductively coupled plasma-mass spectrometry (ICP-MS) was evaluated using continuous propagation model of uncertainty. The x, y relative error concept and double error regression method for calibration curve fitting were introduced. The results showed that the lower the concentration of Sb in the sample, the greater the relative uncertainty of the measurement results. And the sub-uncertainty from the fitting of the calibration curve seems one of the major contributor to the expanded uncertainty.
Keywords:inductively coupled plasma-mass spectrometry  antimony  groundwater  uncertainty evalution  regression of double error
本文献已被 CNKI 万方数据 等数据库收录!
点击此处可从《岩矿测试》浏览原始摘要信息
点击此处可从《岩矿测试》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号