1.
In cities and urban areas, building structures located at close proximities inevitably interact under dynamic loading by direct pounding and indirectly through the underlying soil. Majority of the previous adjacent building pounding studies that have taken the structure–soil–structure interaction (SSSI) problem into account have used simple lumped mass–spring–dashpot models under plane strain conditions. In this research, the problem of SSSI‐included pounding problem of two adjacent symmetric in plan buildings resting on a soft soil profile excited by uniaxial earthquake loadings is investigated. To this end, a series of SSSI models considering one‐directional nonlinear impact elements between adjacent co‐planar stories and using a method for direct finite element modeling of 3D inelastic underlying soil volume has been developed to accurately study the problem. An advanced inelastic structural behavior parameter, the seismic damage index, has been considered in this study as the key nonlinear structural response of adjacent buildings. Based on the results of SSSI and fixed base case analyses presented herein, two main problems are investigated, namely, the minimum building separation distance for pounding prevention and seismic pounding effects on structural damage in adjacent buildings. The final results show that at least three times, the International Building Code 2009 minimum distance for building separation recommended value is required as a clear distance for adjacent symmetric buildings to prevent the occurrence of seismic pounding. At the International Building Code‐recommended distance, adjacent buildings experienced severe seismic pounding and therefore significant variations in storey shear forces and damage indices. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

2.
This paper addresses the issue of structural system identification using earthquake‐induced structural response. The proposed methodology is based on the subspace identification algorithm to perform identification of structural dynamic characteristics using input–output seismic response data. Incorporated with subspace identification algorithm, a scheme to remove spurious modes is also used to identify real system poles. The efficiency of the proposed method is shown by the analysis of all measurement data from all measurement directly. The recorded seismic response data of three structures (one 7‐story RC building, one midisolation building, and one isolated bridge), under Taiwan Strong Motion Instrumentation Program, are analyzed during the past 15 years. The results present the variation of the identified fundamental modal frequencies and damping ratios from all the recorded seismic events that these three structures had encountered during their service life. Seismic assessment of the structures from the identified system dynamic characteristics during the period of their service is discussed. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

3.
Analysis and comparison of the dynamic responses of three well instrumented (with accelerographs) high-rise buildings shaken during the 1984 Morgan Hill earthquake are presented. The buildings examined in the present work are (i) the Town Park Towers Apartment building, a 10-storey, concrete shear wall building; (ii) the Great Western Savings and Loan building, a 10-storey building with concrete frames and shear walls; and (iii) the Santa Clara County Office building, a 13-storey, moment-resistant steel frame building. The structures are located within 2 km of each other and, as may be confirmed by visual inspection of the recorded seismograms, experienced similar ground motions. One-dimensional and three-dimensional linear structural models are fitted to the observations using the modal minimization method' for structural identification, in order to determine optimal estimates of the parameters of the dominant modes of the buildings. The time-varying character of these parameters over the duration of the response is also investigated. Comparison of the recorded earthquake response of the structures reveals that the type of lateral-load-resisting system has an important effect on the dynamic behaviour of the structures because it controls the spacing of the characteristic modes on the frequency axis. The Santa Clara County Office building has closely spaced natural frequencies and exhibits strong torsional response and modal coupling. Its dynamic behaviour is contrasted with that of the Great Western Savings and Loan building which has well separated natural frequencies and exhibits small torsional response and no modal coupling. Strong modal coupling causes a beating-type phenomenon and makes earthquake response of structures different from that envisioned by codes.  相似文献   

4.
This paper reviews the theoretical principles of subspace system identification as applied to the problem of estimating black‐box state‐space models of support‐excited structures (e.g., structures exposed to earthquakes). The work distinguishes itself from past studies by providing readers with a powerful geometric interpretation of subspace operations that relates directly to theoretical structural dynamics. To validate the performance of subspace system identification, a series of experiments are conducted on a multistory steel frame structure exposed to moderate seismic ground motions; structural response data is used off‐line to estimate black‐box state‐space models. Ground motions and structural response measurements are used by the subspace system identification method to derive a complete input–output state‐space model of the steel frame system. The modal parameters of the structure are extracted from the estimated input–output state‐space model. With the use of only structural response data, output‐only state‐space models of the system are also estimated by subspace system identification. The paper concludes with a comparison study of the modal parameters extracted from the input–output and output‐only state‐space models in order to quantify the uncertainties present in modal parameters extracted from output‐only models. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

5.
This paper presents applications of the modified 3D‐SAM approach, a three‐dimensional seismic assessment methodology for buildings directly based on in situ experimental modal tests to calculate global seismic demands and the dynamic amplification portion of natural torsion. Considering that the building modal properties change from weak to strong motion levels, appropriate modification factors are proposed to extend the application of the method to stronger earthquakes. The proposed approach is consistent with the performance‐based seismic assessment approach, which entails the prediction of seismic displacements and drift ratios that are related to the damage condition and therefore the functionality of the building. The modified 3D‐SAM is especially practical for structures that are expected to experience slight to moderate damage levels and in particular for post‐disaster buildings that are expected to remain functional after an earthquake. In the last section of this paper, 16 low to mid‐rise irregular buildings located in Montreal, Canada, and that have been tested under ambient vibrations are analyzed with the method, and the dynamic amplification portion of natural torsion of the dataset is reported and discussed. The proposed methodology is appropriate for large‐scale assessments of existing buildings and is applicable to any seismic region of the world. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

6.
Tracking modal parameters and estimating the current structural state of a building from seismic response measurements, particularly during strong earthquake excitations, can provide useful information for building safety assessment and the adaptive control of a structure. Therefore, online or recursive identification techniques need to be developed and implemented for building seismic response monitoring. This paper develops and examines different methods to track modal parameters from building seismic response data. The methods include recursive data‐driven subspace identification (RSI‐DATA) using Givens rotation algorithm, and RSI‐DATA using Bona fide algorithm. The question on how well the results of RSI‐DATA reflect the real condition is investigated and verified with a bilinear SDOF simulation study. Time‐varying modal parameters of a four‐story reinforced concrete school building are identified based on a series of earthquake excitations, including several seismic events, large and small. Discussions on the different methods' ability to track the time‐varying modal parameters are presented. The variation of the identified building modal frequencies and damping ratios from a series of event‐by‐event seismic responses, particularly before and after retrofitting of the building is also discussed. Copyright © 2017 John Wiley & Sons, Ltd.  相似文献   

7.
Recent earthquakes, that stroked Italian regions in past decades (Umbria— Marche 1997; Molise 2002; L’Aquila 2009), pointed out the high vulnerability of reinforced concrete existing buildings causing severe damages in the structures and consequently life losses. This is mainly due to the fact that such structures were often built without reference to seismic actions or on the basis of old standard provisions. Nowadays in Italy, Public Authorities are requested to evaluate the seismic vulnerability of their building stock assessing the actual capacity of such structures, as a consequence of new hazard levels and seismic microzonation introduced by new standards. According to Eurocode 8 or Italian standard NTC 2008, the seismic analysis of existing reinforced concrete buildings can be performed by one of the established procedure (i.e. Linear Static Analysis LSA, Linear Dynamic Analysis LDA, Nonlinear Static Analysis NSA, Nonlinear Dynamic Analysis NDA), depending on the achieved knowledge level about the structural system and materials. In order to compare efficiency and differences of previously described approaches, a deep investigation was executed on a reinforced concrete existing building whose dynamic behaviour was evaluated by an experimental dynamic analysis. In such a way, updated models were obtained and adopted for seismic analysis performed by using linear and nonlinear approaches, taking into account the stiffness and strength contribution of masonry infill walls. It was so possible to get useful indications on the reliability and discrepancies of different modelling approaches as well as on the influence of masonry infills on the seismic response of existing r.c. buildings.  相似文献   

8.
Closed‐form solution for seismic response of adjacent buildings connected by hydraulic actuators with linear quadratic Gaussian (LQG) controllers is presented in this paper. The equations of motion of actively controlled adjacent buildings against earthquake are first established. The complex modal superposition method is then used to determine dynamic characteristics, including modal damping ratio, of actively controlled adjacent buildings. The closed‐form solution for seismic response of the system is finally derived in terms of the complex dynamic characteristics, the pseudo‐excitation method and the residue theorem. By using the closed‐form solution, extensive parametric studies can be carried out for the system of many degrees of freedom. The beneficial parameters of LQG controllers for achieving the maximum response reduction of both buildings using reasonable control forces can be identified. The effectiveness of LQG controllers for this particular application is evaluated in this study. The results show that for the adjacent buildings of different dynamic properties, if the parameters of LQG controllers are selected appropriately, the modal damping ratios of the system can be significantly increased and the seismic responses of both buildings can be considerably reduced. Copyright © 2001 John Wiley & Sons, Ltd.  相似文献   

9.
Incremental dynamic analysis (IDA)—a procedure developed for accurate estimation of seismic demand and capacity of structures—requires non‐linear response history analysis of the structure for an ensemble of ground motions, each scaled to many intensity levels, selected to cover the entire range of structural response—all the way from elastic behaviour to global dynamic instability. Recognizing that IDA of practical structures is computationally extremely demanding, an approximate procedure based on the modal pushover analysis procedure is developed. Presented are the IDA curves and limit state capacities for the SAC‐Los Angeles 3‐, 9‐, and 20‐storey buildings computed by the exact and approximate procedures for an ensemble of 20 ground motions. These results demonstrate that the MPA‐based approximate procedure reduces the computational effort by a factor of 30 (for the 9‐storey building), at the same time providing results to a useful degree of accuracy over the entire range of responses—all the way from elastic behaviour to global dynamic instability—provided a proper hysteretic model is selected for modal SDF systems. The accuracy of the approximate procedure does not deteriorate for 9‐ and 20‐storey buildings, although their dynamics is more complex, involving several ‘modes’ of vibration. For all three buildings, the accuracy of the MPA‐based approximate procedure is also satisfactory for estimating the structural capacities for the limit states of immediate occupancy, collapse prevention, and global dynamic instability. Copyright © 2006 John Wiley & Sons, Ltd.  相似文献   

10.
As high‐rise buildings are built taller and more slender, their dynamic behavior becomes an increasingly critical design consideration. Wind‐induced vibrations cause an increase in the lateral wind design loads, but more importantly, they can be perceived by building occupants, creating levels of discomfort ranging from minor annoyance to severe motion sickness. The current techniques to address wind vibration perception include stiffening the lateral load‐resisting system, adding mass to the building, reducing the number of stories, or incorporating a vibration absorber at the top of the building; each solution has significant economic consequences for builders. Significant distributed damage is also expected in tall buildings under severe seismic loading, as a result of the ductile seismic design philosophy that is widely used for such structures. In this paper, the viscoelastic coupling damper (VCD) that was developed at the University of Toronto to increase the level of inherent damping of tall coupled shear wall buildings to control wind‐induced and earthquake‐induced dynamic vibrations is introduced. Damping is provided by incorporating VCDs in lieu of coupling beams in common structural configurations and therefore does not occupy any valuable architectural space, while mitigating building tenant vibration perception problems and reducing both the wind and earthquake responses of the structure. This paper provides an overview of this newly proposed system, its development, and its performance benefits as well as the overall seismic and wind design philosophy that it encompasses. Two tall building case studies incorporating VCDs are presented to demonstrate how the system results in more efficient designs. In the examples that are presented, the focus is on the wind and moderate earthquake responses that often govern the design of such tall slender structures while reference is made to other studies where the response of the system under severe seismic loading conditions is examined in more detail and where results from tests conducted on the viscoelastic material and the VCDs in full‐scale are presented. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

11.
This paper investigates the seismic response of multi‐storey cross‐laminated timber (CLT) buildings and its relationship with salient ground‐motion and building characteristics. Attention is given to the effects of earthquake frequency content on the inelastic deformation demands of platform CLT walled structures. The response of a set of 60 CLT buildings of varying number of storeys and panel fragmentation levels representative of a wide range of structural configurations subjected to 1656 real earthquake records is examined. It is shown that, besides salient structural parameters like panel aspect ratio, design behaviour factor, and density of joints, the frequency content of the earthquake action as characterized by its mean period has a paramount importance on the level of nonlinear deformations attained by CLT structures. Moreover, the evolution of drifts as a function of building to ground‐motion periods ratio is different for low‐ and high‐rise buildings. Accordingly, nonlinear regression models are developed for estimating the global and interstorey drifts demands on multi‐storey CLT buildings. Finally, the significance of the results is highlighted with reference to European seismic design procedures and recent assessment proposals.  相似文献   

12.
The growing number of demand for a widespread of health monitoring for strategic buildings in seismic areas has emphasized the need to realize in-depth scientific studies, in order to verify the feasibility of economic and fast methods to detect anomalous vibrations, to execute post earthquake warning and monitoring, damage assessment and first damage scenarios. Generally, an effective system for structural health monitoring requires an appropriate number of sensors, suitably located in the structures, and complex elaborations of big amounts of data. The simplified method presented in this paper is based on a statistical approach that uses the most significant data recorded on the top floor of the building, with the purpose of extracting information on the maximum inter-story drift, used as damage indicator. The parameters considered in the method are (i) maximum top acceleration, (ii) the first modal frequency variations and (iii) the equivalent structural viscous damping variation. A big amount of experimental data relevant to several tests carried out on scaled R/C models and numerical non linear dynamic analyses have been used to verify the feasibility of this approach.  相似文献   

13.
Past earthquake experiences indicate that most buildings designed in accordance with modern seismic design codes could survive moderate‐to‐strong earthquakes; however, the financial loss due to repairing cost and the subsequent business interruption can be unacceptable. Designing building structures to meet desired performance targets has become a clear direction in future seismic design practice. As a matter of fact, the performance of buildings is affected by structural as well as non‐structural components, and involves numerous uncertainties. Therefore, appropriate probabilistic approach taking into account structural and non‐structural damages is required. This paper presents a fuzzy–random model for the performance reliability analysis of RC framed structures considering both structural and non‐structural damages. The limit state for each performance level is defined as an interval of inter‐storey drift ratios concerning, respectively, the non‐structural and structural damage with a membership function, while the relative importance of the two aspects is reflected through the use of an appropriate cost function. To illustrate the methodology, herein the non‐structural damage is represented by infill masonry walls. The probabilistic drift limits for RC components and masonry walls from the associated studies are employed to facilitate the demonstration of the proposed model in an example case study. The results are compared with those obtained using classical reliability model based on single‐threshold performance definition. The proposed model provides a good basis for incorporating different aspects into the performance assessment of a building system. Copyright © 2005 John Wiley & Sons, Ltd.  相似文献   

14.
Seismic behavior of damaged buildings may be expressed as a function of their REsidual Capacity (REC), which is a measure of seismic capacity, reduced by damage. REC can be interpreted as the median value of collapse vulnerability curves. Its variation owing to damage is a useful indication of increased building vulnerability. REC reduction, indicating the lowering of seismic safety after an earthquake (performance loss, PL), represents an effective index for assessing the need of seismic repair/strengthening after earthquakes. The study investigates the applicability of a pushover‐based method in the analysis of damaged structures for the case of existing under‐designed RC buildings. The paper presents a systematization of the procedure in an assessment framework that applies the capacity spectrum method based on inelastic demand spectra; furthermore, the vulnerability variation of a real building is investigated with a detailed case study. The behavior of damaged buildings is simulated with pushover analysis through suitable modification of plastic hinges (in terms of stiffness, strength and residual drift) for damaged elements. The modification of plastic hinges has been calibrated in tests on nonconforming columns. The case study analysis evidenced that, for minor or moderate damages, the original structural displacement capacity was only slightly influenced, but the ductility capacity was significantly reduced (up to 40%) because of the increased structure deformability. This implied performance loss in the range 10%–20%. For severe damages the PL ranged between 41% and 56%. Local mechanism types exhibit PL nearly double with respect to global mechanism types. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

15.
The investigation reported in this paper studies the effects of soil–structure interaction (SSI) on the seismic response and damage of building–foundation systems. A simple structural model is used for conducting a parametric study using a typical record obtained in the soft soil area of Mexico City during the 1985 earthquake. Peak response parameters chosen for this study were the roof displacement relative to the base and the hysteretic energy dissipated by the simple structural model. A damage parameter is also evaluated for investigating the SSI effects on the seismic damage of buildings. The results indicate that in most cases of inelastic response, SSI effects can be evaluated considering the rigid‐base case and the SSI period. Copyright © 2000 John Wiley & Sons, Ltd.  相似文献   

16.
Coupling adjacent buildings using discrete viscoelastic dampers for control of response to low and moderate seismic events is investigated in this paper. The complex modal superposition method is first used to determine dynamic characteristics, mainly modal damping ratio and modal frequency, of damper-linked linear adjacent buildings for practical use. Random seismic response of linear adjacent buildings linked by dampers is then determined by a combination of the complex modal superposition method and the pseudo-excitation method. This combined method can effectively and accurately determine random seismic response of non-classically damped systems in the frequency domain. Parametric studies are finally performed to identify optimal parameters of viscoelastic dampers for achieving the maximum modal damping ratio or the maximum response reduction of adjacent buildings. It is demonstrated that using discrete viscoelastic dampers of proper parameters to link adjacent buildings can reduce random seismic responses significantly. Copyright © 1999 John Wiley & Sons Ltd.  相似文献   

17.
Non‐ductile reinforced concrete buildings represent a prevalent construction type found in many parts of the world. Due to the seismic vulnerability of such buildings, in areas of high seismic activity non‐ductile reinforced concrete buildings pose a significant threat to the safety of the occupants and damage to such structures can result in large financial losses. This paper introduces advanced analytical models that can be used to simulate the nonlinear dynamic response of these structural systems, including collapse. The state‐of‐the‐art loss simulation procedure developed for new buildings is extended to estimate the expected losses of existing non‐ductile concrete buildings considering their vulnerability to collapse. Three criteria for collapse, namely first component failure, side‐sway collapse, and gravity‐load collapse, are considered in determining the probability of collapse and the assessment of financial losses. A detailed example is presented using a seven‐story non‐ductile reinforced concrete frame building located in the Los Angeles, California. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

18.
In conventional modal analysis procedures, usually only a few dominant modes are required to describe the dynamic behavior of multi-degrees-of-freedom buildings. The number of modes needed in the dynamic analysis depends on the higher-mode contribution to the structural response, which is called the higher-mode effect. The modal analysis approach, however, may not be directly applied to the dynamic analysis of viscoelastically damped buildings. This is because the dynamic properties of the viscoelastic dampers depend on their vibration frequency. Therefore, the structural stiffness and damping contributed from those dampers would be different for each mode. In this study, the higher-mode effect is referred to as the response difference induced by the frequency-dependent property of viscoelastic dampers at higher modes. Modal analysis procedures for buildings with viscoelastic dampers distributed proportionally and non-proportionally to the stiffness of the buildings are developed to consider the higher-mode effect. Numerical studies on shear-type viscoelastically damped building models are conducted to examine the accuracy of the proposed procedures and to investigate the significance of the higher-mode effect on their seismic response. Two damper models are used to estimate the peak damper forces in the proposed procedures. Study results reveal that the higher-mode effect is significant for long-period viscoelastically damped buildings. The higher-mode effect on base shear is less significant than on story acceleration response. Maximum difference of the seismic response usually occurs at the top story. Also, the higher-mode effect may not be reduced by decreasing the damping ratio provided by the viscoelastic dampers. For practical application, it is realized that the linear viscous damping model without considering the higher-mode effect may predict larger damper forces and hence, is on the conservative side. Supported by: Science Council, Chinese Taipei, grant no. 88-2625-2-002-006  相似文献   

19.
An approximation approach of seismic analysis of two‐way asymmetric building systems under bi‐directional seismic ground motions is proposed. The procedures of uncoupled modal response history analysis (UMRHA) are extended to two‐way asymmetric buildings simultaneously excited by two horizontal components of ground motion. Constructing the relationships of two‐way base shears versus two‐way roof translations and base torque versus roof rotation in ADRS format for a two‐way asymmetric building, each modal pushover curve bifurcates into three curves in an inelastic state. A three‐degree‐of‐freedom (3DOF) modal stick is developed to simulate the modal pushover curve with the stated bifurcating characteristic. It requires the calculation of the synthetic earthquake and angle β. It is confirmed that the 3DOF modal stick is consistent with single‐degree‐of‐freedom modal stick in an elastic state. A two‐way asymmetric three‐story building was analyzed by UMRHA procedure incorporating the proposed 3DOF modal sticks. The analytical results are compared with those obtained from nonlinear response history analysis. It is shown that the 3DOF modal sticks are more rational and effective in dealing with the assessment of two‐way asymmetric building systems under two‐directional seismic ground motions. Copyright © 2007 John Wiley & Sons, Ltd.  相似文献   

20.
While many cases of structural damage in past earthquakes have been attributed to strong vertical ground shaking, our understanding of vertical seismic load effects and their influence on collapse mechanisms of buildings is limited. This study quantifies ground motion parameters that are capable of predicting trends in building collapse because of vertical shaking, identifies the types of buildings that are most likely affected by strong vertical ground motions, and investigates the relationship between element level responses and structural collapse under multi‐directional shaking. To do so, two sets of incremental dynamic analyses (IDA) are run on five nonlinear building models of varying height, geometry, and design era. The first IDA is run using the horizontal component alone; the second IDA applies the vertical and horizontal motions simultaneously. When ground motion parameters are considered independently, acceleration‐based measures of the vertical shaking best predict trends in building collapse associated with vertical shaking. When multiple parameters are considered, Housner intensity (SI), computed as a ratio between vertical and horizontal components of a record (SIV/SIH), predicts the significance of vertical shaking for collapse. The building with extensive structural cantilevered members is the most influenced by vertical ground shaking, but all frame structures (with either flexural and shear critical columns) are impacted. In addition, the load effect from vertical ground motions is found to be significantly larger than the nominal value used in US building design. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   