New steel moment‐resisting connections that incorporate post‐tensioning elements to provide a self‐centering capacity and devices to dissipate seismic input energy have recently been proposed and experimentally validated. Experimental studies have confirmed that these connections are capable of undergoing large lateral deformations with negligible residual drifts. To facilitate their implementation, accurate modeling of the behavior of systems incorporating post‐tensioned connections must be readily available to designers and researchers. A number of simplified models have been suggested in the literature by researchers trying to capture experimental results at the beam–column connections and thereby to predict the global response of structures incorporating such connections. To provide a clear set of guidelines for the modeling of post‐tensioned steel frames, for practicing engineers as well as researchers, in this paper three types of numerical models of increasing complexity are presented: (i) a sectional analysis procedure, (ii) a lumped plasticity spring frame leveled approach and (iii) a non‐linear solid finite element analysis to predict the response at ultimate deformation levels. The analytical results obtained from the numerical models predict well the structural behavior of these connections when compared with available experimental data. Even at the ultimate deformation level, analytical results are in good agreement with test results. Furthermore, detailing requirements are proposed to assure that flexural hinges form in the beams in order to improve the cyclic response of steel self‐centering connections when drifts exceeding the design drifts are imposed to the system. Experimental and analytical studies demonstrate that steel post‐tensioned self‐centering connections incorporating the proposed detailing in the beams develop an increased deformation capacity and thereby exhibit a ductile response while avoiding a sudden loss of their strength and stiffness. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

2.
The self‐centering prestressed concrete (SCPC) moment resisting frame (MRF) with web friction devices (WFDs) is a new type of structure that integrates advantages of post‐tensioned precast concrete MRFs and self‐centering steel MRFs. In this paper, the configuration of the connection and design guidelines are presented. To further reduce damage to the connection under cyclic loading and facilitate implementation in practice, several significant improvements are proposed and experimentally validated in this study, including the following: (i) the welded connection is replaced by the bolted connection; (ii) aluminum plates are used for friction instead of brass plates to reduce the material costs without decreasing the energy dissipation capacity; and (iii) post‐tensioned tendons at the corners of the beam are replaced by a bundle of tendons at the beam centroid in order to facilitate the field assembly. The resulting improvements of seismic performances are experimentally demonstrated by 10 cyclic tests of two full‐scale SCPC beam–column connections. Numerical simulation of the proposed connection is conducted using the Open System for Earthquake Engineering Simulation (OpenSees) to replicate the experimental results. Seismic behaviors are taken into account, such as the gap opening/closing at the beam–column interface, the self‐centering capacity, and the friction energy dissipation. Good agreement is observed between the numerical simulation and the test results. The proposed SCPC connection with bolted WFDs is demonstrated to have good performance when subjected to cyclic loading. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

3.
Self‐centering reinforced concrete frames are developed as an alternative of traditional seismic force‐resisting systems with better seismic performance and re‐centering capability. This paper presents an experimental and computational study on the seismic performance of self‐centering reinforced concrete frames. A 1/2‐scale model of a two‐story self‐centering reinforced concrete frame model was designed and tested on the shaking table in State Key Laboratory of Disaster Reduction in Civil Engineering at Tongji University to evaluate the seismic behavior of the structure. A structural analysis model, including detailed modeling of beam–column joints, column–base joints, and prestressed tendons, was constructed in the nonlinear dynamic modeling software OpenSEES. Agreements between test results and numerical solutions indicate that the designed reinforced concrete frame has satisfactory seismic performance and self‐centering capacity subjected to earthquakes; the self‐centering structures can undergo large rocking with minor residual displacement after the earthquake excitations; the proposed analysis procedure can be applied in simulating the seismic performance of self‐centering reinforced concrete frames. To achieve a more comprehensive evaluation on the performance of self‐centering structures, research on energy dissipation devices in the system is expected. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

4.
Six cyclic tests were conducted on three full‐scale subassemblies to investigate the behavior of interior beam‐to‐column post‐tensioned (PT) connections. Strands were placed along each side of the steel beam web, passing through the steel column to provide precompression between the beams and a column. Top and bottom energy‐dissipating (ED) bars, passing through the column and welded to the beam, were used to increase the moment capacity and ED capacity of the connection. One of the subassemblies also had a composite concrete slab with discontinuity at the column centerline to eliminate restraint from the metal deck, reinforcement, and welded wire mesh. The objectives of this paper were to investigate the following: the durability of the connection by loading each specimen twice, the ED capacity of the ED bar, and the effects that the type of ED bar and type of composite slab have on the self‐centering behavior of the connection. The experimental results showed that: (1) the connection could sustain severe inelastic cyclic loading at least twice without strength degradation, (2) the ED capacity of the bar was much larger than that dissipated by a single AISC loading protocol, and (3) a specimen with a discontinuous composite slab, which opened freely at the centerline of the column, ensured the same self‐centering hysteretic behavior as the bare steel specimen. However, the decompression moment of the PT connection decreased significantly at each interstory drift, resulting in an early opening of a gap at the beam–column interface. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

5.
The biaxial response of two bridge piers is experimentally investigated. A post‐tensioned precast bridge pier with external replaceable mild‐steel dissipaters is tested under biaxial loading. The performance of the post‐tensioned bridge pier is compared with a conventionally reinforced monolithic bridge pier. The experimental biaxial response is then compared with previous uniaxial experimental testing of identical bridge piers to understand the influence of biaxial loading, specifically concerning post‐tensioned rocking sections. A 3‐dimensional moment–curvature and moment–rotation analysis program is created to generate the monotonic section response of a conventional and post‐tensioned bridge pier. After comparing the accuracy of the section analysis program to the experimental testing of the monolithic pier, the program is validated against the experimental testing of the post‐tensioned bridge pier. This section analysis program is then used in the calibration of a macro‐model to capture the entire cyclic response of the post‐tensioned bridge pier. The macro‐model adopts multiple linear‐elastic compression‐only springs at the rocking interface, combined with non‐linear inelastic springs for each of the mild‐steel dissipaters and returns encouraging results at both local and global levels. The paper concludes with a number of biaxial moment‐interaction design charts for monolithic and post‐tensioned bridge piers as a function of mechanical and geometric section properties. The design charts define the biaxial yield surface at nominal yield and at the design section capacity defined by one of three material limit states. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

6.
Post‐tensioned (PT) self‐centering moment frames were developed as an alternative to welded moment‐resisting frames (MRFs). Lateral deformation of a PT frame opens gaps between beams and columns. The use of a composite slab in welded MRFs limits the opening of gaps at the beam‐to‐column interfaces but cannot be adopted in PT self‐centering frames. In this study, a sliding slab is used to minimize restraints to the expansion of the PT frame. A composite slab is rigidly connected to the beams in a single bay of the PT frame. A sliding device is installed between the floor beams and the beams in other bays, wherever the slab is allowed to slide. Many shaking table tests were conducted on a reduced‐scale, two‐by‐two bay one‐story specimen, which comprised one PT frame and two gravitational frames (GFs). The PT frame and GFs were self‐centering throughout the tests, responding in phase with only minor differences in peak drifts that were caused by the expansion of the PT frame. When the specimen was excited by the 1999 Chi‐Chi earthquake with a peak ground acceleration of 1.87g, the maximum interstory drift was 7.2% and the maximum lateral force was 270 kN, equal to 2.2 times the yield force of the specimen. Buckling of the beam bottom flange was observed near the column face, and the initial post‐tensioning force in the columns and beams decreased by 50 and 22%, respectively. However, the specimen remained self‐centering and its residual drift was 0.01%. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

7.
The self‐centering rocking steel frame is a seismic force resisting system in which a gap is allowed to form between a concentrically braced steel frame and the foundation. Downward vertical force applied to the rocking frame by post‐tensioning acts to close the uplifting gap and thus produces a restoring force. A key feature of the system is replaceable energy‐dissipating devices that act as structural fuses by producing high initial system stiffness and then yielding to dissipate energy from the input loading and protect the remaining portions of the structure from damage. In this research, a series of large‐scale hybrid simulation tests were performed to investigate the seismic performance of the self‐centering rocking steel frame and in particular, the ability of the controlled rocking system to self‐center the entire building. The hybrid simulation experiments were conducted in conjunction with computational modules, one that simulated the destabilizing P‐Δ effect and another module that simulated the hysteretic behavior of the rest of the building including simple composite steel/concrete shear beam‐to‐column connections and partition walls. These tests complement a series of quasi‐static cyclic and dynamic shake table tests that have been conducted on this system in prior work. The hybrid simulation tests validated the expected seismic performance as the system was subjected to ground motions in excess of the maximum considered earthquake, produced virtually no residual drift after every ground motion, did not produce inelasticity in the steel frame or post‐tensioning, and concentrated the inelasticity in fuse elements that were easily replaced. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

8.
Post‐tensioned (PT) self‐centering moment‐resisting frames (MRFs) have recently been developed as an alternative to welded moment frames. The first generation of these systems incorporated yielding energy dissipation mechanisms, whereas more recently, PT self‐centering friction damped (SCFR) moment‐resistant connections have been proposed and experimentally validated. Although all of these systems exhibited good stiffness, strength and ductility properties and stable dissipation of energy under cyclic loading, questions concerning their ultimate response still remained and a complete design methodology to allow engineers to conceive structures using these systems was also needed. In this paper, the mechanics of SCFR frames are first described and a comprehensive design procedure that accounts for the frame behavior and the nonlinear dynamics of self‐centering frames is then elaborated. A strategy for the response of these systems at ultimate deformation stages is then proposed and detailing requirements on the beams in order to achieve this response are outlined. The proposed procedure aims to achieve designs where the interstory drifts for SCFR frames are similar to those of special steel welded moment‐resisting frames (WMRFs). Furthermore, this procedure is adapted from current seismic design practices and can be extended to any other PT self‐centering steel frame system. A six‐story building incorporating WMRFs was designed and a similar building incorporating SCFR frames were re‐designed by the proposed seismic design procedure. Time‐history analyses showed that the maximum interstory drifts and maximum floor accelerations of the SCFR frame were similar to those of the WMRF but that almost zero residual drifts were observed for the SCFR frame. The results obtained from the analyses confirmed the validity of the proposed seismic design procedure, since the peak drift values were similar to those prescribed by the seismic design codes and the SCFR frames achieved the intended performance level under both design and maximum considerable levels of seismic loading. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

9.
The potential of post‐tensioned self‐centering moment‐resisting frames (SC‐MRFs) and viscous dampers to reduce the economic seismic losses in steel buildings is evaluated. The evaluation is based on a prototype steel building designed using four different seismic‐resistant frames: (i) conventional moment resisting frames (MRFs); (ii) MRFs with viscous dampers; (iii) SC‐MRFs; or (iv) SC‐MRFs with viscous dampers. All frames are designed according to Eurocode 8 and have the same column/beam cross sections and similar periods of vibration. Viscous dampers are designed to reduce the peak story drift under the design basis earthquake (DBE) from 1.8% to 1.2%. Losses are estimated by developing vulnerability functions according to the FEMA P‐58 methodology, which considers uncertainties in earthquake ground motion, structural response, and repair costs. Both the probability of collapse and the probability of demolition because of excessive residual story drifts are taken into account. Incremental dynamic analyses are conducted using models capable to simulate all limit states up to collapse. A parametric study on the effect of the residual story drift threshold beyond which is less expensive to rebuild a structure than to repair is also conducted. It is shown that viscous dampers are more effective than post‐tensioning for seismic intensities equal or lower than the maximum considered earthquake (MCE). Post‐tensioning is effective in reducing repair costs only for seismic intensities higher than the DBE. The paper also highlights the effectiveness of combining post‐tensioning and supplemental viscous damping by showing that the SC‐MRF with viscous dampers achieves significant repair cost reductions compared to the conventional MRF. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

10.
Highway bridges in highly seismic regions can sustain considerable residual displacements in their columns following large earthquakes. These residual displacements are an important measure of post‐earthquake functionality, and often determine whether or not a bridge remains usable following an earthquake. In this study, a self‐centering system is considered that makes use of unbonded, post‐tensioned steel tendons to provide a restoring force to bridge columns to mitigate the problem of residual displacements. To evaluate the proposed system, a code‐conforming, case‐study bridge structure is analyzed both with conventional reinforced concrete columns and with self‐centering, post‐tensioned columns using a formalized performance‐based earthquake engineering (PBEE) framework. The PBEE analysis allows for a quantitative comparison of the relative performance of the two systems in terms of engineering parameters such as peak drift ratio as well as more readily understood metrics such as expected repair costs and downtime. The self‐centering column system is found to undergo similar peak displacements to the conventional system, but sustains lower residual displacements under large earthquakes, resulting in similar expected repair costs but significantly lower expected downtimes. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

11.
The cyclic behavior of precast segmental concrete bridge columns with high performance (HP) steel reinforcing bars and that with conventional steel reinforcing bars as energy dissipation (ED) bars were investigated. The HP steel reinforcing bars are characterized by higher strength, greater ductility, and superior corrosion resistance compared with the conventional steel reinforcing bars. Three large‐scale columns were tested. One was designed with the HP ED bars and two with the conventional ED bars. The HP ED bars were fully bonded to the concrete. The conventional ED bars were fully bonded to the concrete for one column, whereas unbonded for a length to delay fracture of the bars and to increase energy dissipation for the other column. Test results showed that the column with the HP ED bars had greater drift capacity, higher lateral strength, and larger energy dissipation than that with fully bonded conventional ED bars. The column with unbonded conventional ED bars achieved the same drift capacity and similar energy dissipation capacity as that with the HP ED bars. All the three columns showed good self‐centering capability with residual drifts not greater than 0.4% drift. An analytical model referred to as joint bar‐slip rotation method for pushover analysis of segmental columns with ED bars is proposed. The model calculates joint rotation from the slip of the ED bars from two sides of the joint. Good agreement was found between analytical predictions and the envelope responses of the three columns. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

12.
This article examines the use of rocking steel braced frames for the retrofit of existing seismically deficient steel building structures. Rocking is also used to achieve superior seismic performance to reduce repair costs and disruption time after earthquakes. The study focuses on low‐rise buildings for which re‐centring is solely provided by gravity loads rather than added post‐tensioning elements. Friction energy dissipative (ED) devices are used to control drifts. The system is applied to 2‐storey and 3‐storey structures located in 2 seismically active regions of Canada. Firm ground and soft soil conditions are considered. The seismic performance of the retrofit scheme is evaluated using nonlinear dynamic analysis and ASCE 41‐13. For all structures, rocking permits to achieve immediate occupancy performance under 2% in 50 years seismic hazard if the braces and their connections at the building's top storeys are strengthened to resist amplified forces due to higher mode response. Base shears are also increased due to higher modes. Impact at column bases upon rocking induces magnified column forces and vertical response in the gravity system. Friction ED is found more effective for drift control than systems with ring springs or bars yielding in tension. Drifts are sufficiently small to achieve position retention performance for most nonstructural components. Horizontal accelerations are generally lower than predicted from ASCE 41 for regular nonrocking structures. Vertical accelerations in the gravity framing directly connected to the rocking frame are however higher than those predicted for ordinary structures. Vertical ground motions have limited effect on frame response.  相似文献   

13.
The seismic performance of post‐tensioned steel connections for moment‐resisting frames was examined experimentally and analytically. Cyclic tests were conducted on three full‐scale subassemblies, which had two steel beams post‐tensioned to a concrete‐filled tube (CFT) column with high‐strength strands to provide recentring response. Reduced flange plates (RFPs) welded to the column and bolted to the beam flange were used to increase the dissipation of energy. Test results indicated that (1) the proposed buckling‐restrained RFP could dissipate energy in axial tension and compression, (2) the subassemblies could reach an interstorey drift of 4% without strength degradation, and (3) buckling of the beam occurred towards an interstorey drift of 5%, causing a loss of the strand force, the recentring response, and the moment capacity. A general‐purpose non‐linear finite element analysis program (ABAQUS) was used to perform a correlation study. The behaviour of the steel beam under both post‐tensioning and flexural loadings was compared to the test results and predictions. Copyright © 2006 John Wiley & Sons, Ltd.  相似文献   

14.
Reversed cyclic loading behavior of jointed precast prestressed concrete beam‐to‐column connections are computationally modeled and validated against full‐scale experimental results. Response simulations are performed with and without supplemental high force‐to‐volume (HF2V) energy dissipation devices. The experimental specimen is a three‐dimensional corner connection of a jointed precast concrete frame structure, utilizing unbonded post‐tensioned tendons consisting of high‐alloy, high‐strength thread‐bars. The joint region is armored, to avoid damage, by providing steel plates at the beam–column (rocking) contact points. The analytical model of the connection is developed to include modifications for the effects of changing connection behavior. These effects are friction within the prestressing system, yielding of the prestressing tendons, reduction or elimination of prestress attributable to prior tendon yield, and directional dependence caused by an asymmetrical prestress system. Particular attention is given to developing a robust model that can accommodate small reversals in the displacement loading. The model is extended to incorporate the effects of the HF2V energy dissipation devices and the associated flexibility from the elements that connect the devices to the structure. Although the model is applied to the use of HF2V (lead extrusion) energy dissipation devices, it is general and can accommodate any non‐linear rate‐dependent damper. The computational model is based almost entirely on rational mechanics and shows good agreement with the full‐scale experimental observations. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

15.
Previous studies have suggested that rocking vibration accompanied by uplift motion might reduce the seismic damage to buildings subjected to severe earthquake motions. This paper reports on the use of shaking table tests and numerical analyses to evaluate and compare the seismic response of base‐plate‐yielding rocking systems with columns allowed to uplift with that of fixed‐base systems. The study is performed using half‐scale three‐storey, 1 × 2 bay braced steel frames with a total height of 5.3 m. Base plates that yield due to column tension were installed at the base of each column. Two types of base plates with different thicknesses are investigated. The earthquake ground motion used for the tests and analyses is the record of the 1940 El Centro NS component with the time scale shortened by a factor of 1/√2. The maximum input acceleration is scaled to examine the structural response at various earthquake intensities. The column base shears in the rocking frames with column uplift are reduced by up to 52% as compared to the fixed‐base frames. Conversely, the maximum roof displacements of the fixed and rocking frames are about the same. It is also noted that the effect of the vertical impact on the column associated with touchdown of the base plate is small because the difference in tensile and compressive forces is primarily due to the self‐limiting tensile force in the column caused by yielding of the base plate. Copyright © 2006 John Wiley & Sons, Ltd.  相似文献   

16.
This paper presents the development, experimental testing, and numerical modelling of a new hybrid timber‐steel moment‐resisting connection that is designed to improve the seismic performance of mid‐rise heavy timber moment‐resisting frames (MRF). The connection detail incorporates specially designed replaceable steel links fastened to timber beams and columns using self‐tapping screws. Performance of the connection is verified through experimental testing of four 2/3 scale beam‐column connections. All 4 connection specimens met the acceptance criteria specified in the AISC 341‐10 provisions for steel moment frames and exhibit high strength, ductility, and energy dissipation capacity up to storey drifts exceeding 4%. All of the timber members and self‐tapping screw connections achieved their design objective, remaining entirely elastic throughout all tests and avoiding brittle modes of failure. To assess the global seismic performance of the newly developed connection in a mid‐rise building, a hybrid timber‐steel building using the proposed moment‐resisting connection is designed and modelled in OpenSees. To compare the seismic performance of the hybrid MRF with a conventional steel MRF, a prototype steel‐only building is also designed and modelled in OpenSees. The building models are subject to a suite of ground motions at design basis earthquake and maximum credible earthquake hazard levels using non‐linear time history analysis. Analytical results show that drifts and accelerations of the hybrid building are similar to a conventional steel building while the foundation forces are significantly reduced for the hybrid structure because of its lower seismic weight. The results of the experimental program and numerical analysis demonstrate the seismic performance of the proposed connection and the ability of the hybrid building to achieve comparable seismic performance to a conventional steel MRF.  相似文献   

17.
This paper first presents the force–deformation relationship of a post‐tensioned (PT) steel beam‐to‐column connection constructed with bolted web friction devices (FDs). This paper then describes the test program conducted in the National Center for Research on Earthquake Engineering, Taiwan, on four bolted FDs and four full‐scale PT beam‐to‐column moment connection subassemblies using the FDs. Tests confirm that (1) the hysteretic behavior of four bolted FDs is very stable, (2) the friction coefficient between the steel plate and the brass shim is about 0.34, (3) the proposed force–deformation relationships reasonably predict the experimental responses of the PT connections under cyclically increasing deformations up to a beam peak rotation of 0.05 rad, and (4) the decompression moments do not degrade as beam cyclic deformations increase. Copyright © 2007 John Wiley & Sons, Ltd.  相似文献   

18.
This paper presents new results of centrifuge model tests exploring the behavior of rocking shallow foundations embedded in dry sand, which provides a variety of factors of safety for vertical bearing. The results of slow (quasi‐static) cyclic tests of rocking shear walls and dynamic shaking tests of single‐column rocking bridge models are presented. The moment–rotation and settlement–rotation relationships of rocking footings are investigated. Concrete pads were placed in the ground soil to support some models with the objective of reducing the settlement induced by rocking. The behavior of rocking foundation was shown to be sensitive to the geometric factor of safety with respect to bearing failure, Lf/Lc, where Lf was the footing length, and the Lc was the critical soil‐footing contact length that would be required to support pure axial loading. Settlements were shown to be small if Lf/Lc was reasonably large. Placement of concrete pads under the edges of the footing was shown to be a promising approach to reduce settlements resulting from rocking, if settlements were deemed to be excessive and also had impacts on the energy dissipation and rocking moment capacity. A general discussion of the tradeoffs between energy dissipation and re‐centering of rocking foundations and other devices is included. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

19.
This paper experimentally investigates the application of damage avoidance design (DAD) philosophy to moment‐resisting frames with particular emphasis on detailing of rocking interfaces. An 80% scale three‐dimensional rocking beam–column joint sub‐assembly designed and detailed based on damage avoidance principles is constructed and tested. Incremental dynamic analysis is used for selecting ground motion records to be applied to the sub‐assembly for conducting a multi‐level seismic performance assessment (MSPA). Analyses are conducted to obtain displacement demands due to the selected near‐ and medium‐field ground motions that represent different levels of seismic hazard. Thus, predicted displacement time histories are applied to the sub‐assembly for conducting quasi‐earthquake displacement tests. The sub‐assembly performed well reaching drifts up to 4.7% with only minor spalling occurring at rocking beam interfaces and minor flexural cracks in beams. Yielding of post‐tensioning threaded bars occurred, but the sub‐assembly did not collapse. The externally attached energy dissipators provided large hysteretic dissipation during large drift cycles. The sub‐assembly satisfied all three seismic performance requirements, thereby verifying the superior performance of the DAD philosophy. Copyright © 2007 John Wiley & Sons, Ltd.  相似文献   

20.
The seismic response of single‐degree‐of‐freedom (SDOF) systems incorporating flag‐shaped hysteretic structural behaviour, with self‐centring capability, is investigated numerically. For a SDOF system with a given initial period and strength level, the flag‐shaped hysteretic behaviour is fully defined by a post‐yielding stiffness parameter and an energy‐dissipation parameter. A comprehensive parametric study was conducted to determine the influence of these parameters on SDOF structural response, in terms of displacement ductility, absolute acceleration and absorbed energy. This parametric study was conducted using an ensemble of 20 historical earthquake records corresponding to ordinary ground motions having a probability of exceedence of 10% in 50 years, in California. The responses of the flag‐shaped hysteretic SDOF systems are compared against the responses of similar bilinear elasto‐plastic hysteretic SDOF systems. In this study the elasto‐plastic hysteretic SDOF systems are assigned parameters representative of steel moment resisting frames (MRFs) with post‐Northridge welded beam‐to‐column connections. In turn, the flag‐shaped hysteretic SDOF systems are representative of steel MRFs with newly proposed post‐tensioned energy‐dissipating connections. Building structures with initial periods ranging from 0.1 to 2.0s and having various strength levels are considered. It is shown that a flag‐shaped hysteretic SDOF system of equal or lesser strength can always be found to match or better the response of an elasto‐plastic hysteretic SDOF system in terms of displacement ductility and without incurring any residual drift from the seismic event. Copyright © 2002 John Wiley & Sons, Ltd.  相似文献   