首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A study is made of the effect of soil-structure interaction on the coupled lateral and torsional responses of asymmetric buildings subjected to a series of historical free-field earthquake base motions. It sh shown that for particular classes of actual buildings the equivalent rigid-base responses are significantly increased for structures founded on medium-stiff soils, and hence the assumption of the major building codes that a conservative estimate of response is obtained by considering the structure to be fixed rigidly at its base is shown to be inconsistent with the presented dynamic results. It is shown that foundation interaction produces greatest amplification of torsional coupling effects for structures subjected to a particular class of European strong-motion earthquake records, identified by similarities in their spectral shape, for which the vibrational energy of the ground motion is distributed approximately uniformly over the range of frequencies which are of interest for real structures. It is recommended that provision be made in the torsional design procedures of building codes for the increase in the coupled torsional response due to soil-structure interaction as indicated in this study. Such provision should be based on the results of comprehensive parametric studies employing a wide selection of earthquake records and accounting for expected variations in localized soil conditions.  相似文献   

2.
The effectiveness of the design recommendations made by various major building codes to account for torsional coupling effects is evaluated with respect to the parametric responses to earthquake ground motion of a simple single-storey asymmetric building model supported on an elastic foundation. The objectives are to determine the extent to which the response trends observed in previous studies of asymmetric rigidly based buildings are affected by changes in the flexibility of the foundation medium and to comment on and suggest necessary amendments to the design recommendations in order that suitable allowance be made for the resultant changes in the magnitude of torsional coupling effects. It is concluded that whilst the qualitative effects of torsional coupling are not affected by soil–structure interaction, their magnitude depends significantly on the frequency content of the free-field motion. The response to the El Centro earthquake record is conservatively accounted for by assuming the structure to be supported on a rigid foundation. An allowance for increased response effects due to soil–structure interaction is suggested for incorporation in the torsional design recommendations when European earthquake records are employed.  相似文献   

3.
The work presented in this paper investigates the effect of the foundation flexibility on the coupled lateral-torsional response of single-storey buildings excited by translational ground motion. The eccentricity between the centre of mass and the centre of resistance is considered to be the only cause of coupling of the lateral and torsional response of the building. The study is confined to the steady-state response of rigidly supported and flexibly supported torsionally coupled buildings subjected to harmonic free-field ground displacement perpendicular to the direction of the eccentricity. In the case of the flexibly supported building the foundation medium is assumed to be an elastic homogeneous isotropic half-space. The effect of the controlling parameters on lateral-torsional coupling is investigated. It is concluded that for a particular range of values of these parameters (representing most cases of actual buildings) their effect on the coupling of lateral and torsional response is not qualitatively affected by increases in the flexibility of the foundation medium.  相似文献   

4.
In this paper a probabilistic approach has been adopted to study both the effects of uncertainty in earthquake frequency content and the correlation between earthquake frequency content and ground motion intensity on the response of a single-storey torsionally coupled elastic structure. The earthquake ground motion has been assumed to be a Gaussian, zero mean, stationary random process which is fully characterized by a power spectrum. The ground acceleration power spectrum is idealized as a probabilistic normalized power spectrum computed from actual earthquake records. The advantage of such an idealization is that it enables the effect of the natural frequency as a controlling structural parameter in torsional coupling to be assessed. Comparisons of the dynamic amplifications of eccentricity with those obtained from modern codes of practice and conventional response spectrum analyses have been made. The results of this study have shown that the variation in the frequency content has a significant effect on the response of low frequency structures, while the correlation between the frequency content and the intensity of seismic ground motion is insignificant for the wide range of structures considered. The structure natural frequency has been shown to be an important controlling parameter in the torsionally coupled response of structures subject to seismic loading. The frequency dependence of the dynamic amplification of eccentricity was found not to be reflected in the response spectrum analysis and the torsional provisions of modern building codes.  相似文献   

5.
A study is made on the torsional-lateral motions of non-linear symmetrical structures subjected to lateral ground motion. The torsional and lateral response of a single mass symmetrical system subjected to sinusoidal ground motion is investigated. The load-displacement relationship of the resisting elements is taken to be weakly nonlinear of a softening type. It is shown that non-linear coupling exists between the lateral and rotational motions. For sinusoidal lateral response, the torsional motion equation can be cast in the form of a Mathieu equation. The likelihood of induced torsional response is then studied in terms of unstable regions in the parametric amplitude-frequency parameter space. The implication of this type of non-linear torsional-lateral coupling to the responses of real symmetrical structures subjected to actual earthquake ground motion is then discussed.  相似文献   

6.
A study is made of the dynamic behaviour of multistorey steel rigid-frame buildings with set-back towers. The effects of set-backs upon the building frequencies and mode shapes are examined. Then the effects of set-backs on seismic response are investigated by analysing the response of a series of set-back building frame models to the El Centro ground motion. Finally, the computed responses to the El Centro earthquake are compared with some code provisions dealing with the seismic design of set-back buildings. The conclusions derived from the study include the following:
  • 1. The higher modes of vibration of a set-back building can make a very substantial contribution to its total seismic response; this contribution increases with the slenderness of the tower.
  • 2. Some of the important response parameters for the tower portion of a set-back building are substantially larger than for a related uniform building.
  • 3. For very slender towers, the transition region between the tower and the base may be subjected to very large storey shears.
  相似文献   

7.
The inelastic behaviour of eccentric single-storey building structures subjected to sinusoidal ground excitation is examined. The Kryloff-Bogoliuboff method is employed to provide approximate solutions in the amplitude-frequency domain. Structural resisting elements are assumed to exhibit bilinear hysteretic behaviour and coupled response is investigated in terms of both system response as well as individual element ductility requirements. In addition to demonstrating the well-known softening property inherent in yielding systems, the importance of the principal parameters governing coupled response is evaluated in a consistent parametric fashion. Within the context of earthquake resistant building design, the results indicate the absence of amplified response when torsional and translational frequencies are close, in contrast to the much emphasized observation of internal resonance for linear elastic structures. Equally important, structural elements located on the stiff edge of eccentric buildings are found to be only marginally affected by the magnitude of the eccentricity, thus indicating that seismic building codes which reduce design requirements for these elements underestimate actual behaviour substantially.  相似文献   

8.
Overturning of a structure causes variations in the normal loads of the isolators supporting that structure. For frictional isolators, such variation leads to changes in the frictional forces developed and, hence, in the strength distribution in plan. For frictional pendulum system (FPS) isolators, it also causes changes in the pendular action, i.e. in the stiffness distribution of the isolation interface. Therefore, although the structure is nominally symmetric it develops lateral–torsional coupling when it is subjected to two horizontal components of ground motion. This coupling is denoted herein as accidental torsion due to overturning, and its effect in the earthquake response of nominally symmetric structures is evaluated. Several parameters are identified to control this coupling, but the most important are the slenderness of the structure and the aspect ratio of the building plan. Results are presented in terms of the torsional amplification of the deformations of the isolation base and the interstorey deformations of the superstructure. The FPS system is modelled accurately by including true large deformations and the potential uplift and impact of the isolators. Impulsive as well as subduction‐type ground motions are considered in the analysis, but results show small differences between them. An upper bound for the mean‐plus‐one standard deviation values of the torsional amplifications for the base due to this accidental torsion is 5%. This implies that for design purposes of the isolation system such increase in deformations could probably be neglected. However, the same amplification for the interstorey deformations may be as large as 50%, depending on the torsional stiffness and slenderness of the superstructure, and should be considered in design. In general, such amplification of deformations decreases for torsionally stiffer structures and smaller height‐to‐base aspect ratios. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

9.
Analysis and comparison of the dynamic responses of three well instrumented (with accelerographs) high-rise buildings shaken during the 1984 Morgan Hill earthquake are presented. The buildings examined in the present work are (i) the Town Park Towers Apartment building, a 10-storey, concrete shear wall building; (ii) the Great Western Savings and Loan building, a 10-storey building with concrete frames and shear walls; and (iii) the Santa Clara County Office building, a 13-storey, moment-resistant steel frame building. The structures are located within 2 km of each other and, as may be confirmed by visual inspection of the recorded seismograms, experienced similar ground motions. One-dimensional and three-dimensional linear structural models are fitted to the observations using the modal minimization method' for structural identification, in order to determine optimal estimates of the parameters of the dominant modes of the buildings. The time-varying character of these parameters over the duration of the response is also investigated. Comparison of the recorded earthquake response of the structures reveals that the type of lateral-load-resisting system has an important effect on the dynamic behaviour of the structures because it controls the spacing of the characteristic modes on the frequency axis. The Santa Clara County Office building has closely spaced natural frequencies and exhibits strong torsional response and modal coupling. Its dynamic behaviour is contrasted with that of the Great Western Savings and Loan building which has well separated natural frequencies and exhibits small torsional response and no modal coupling. Strong modal coupling causes a beating-type phenomenon and makes earthquake response of structures different from that envisioned by codes.  相似文献   

10.
An analysis is made of the coupled lateral-torsional response of a partially symmetric single-storey building model to horizontal translatory earthquake excitation. Interest centres on the evaluation of realistic estimates for two equivalent static actions (a shear and a torque) which account for the worst dynamic consequences of torsional unbalance. The results substantiate the findings of previous investigations which have given rise to the belief that strong modal coupling and severely coupled lateral and torsional responses are possible even in nominally symmetric buildings. The response of the model is assumed to be linearly elastic and viscously damped. In a preliminary analysis the equations of motion are solved using the modal analysis technique and the conditions necessary for full modal coupling are ascertained. Then by employing the design spectrum concept, together with suitably conservative procedures for combining the modal maxima, dimensionless forms of the equivalent static actions are evaluated as functions of two independent parameters. The final results are furnished by modified square root of the sum of the squares (SRSS) combination functions which take account of the spacing between the translational and torsional frequencies. Examples at the end of the paper illustrate the practical significance of the work.  相似文献   

11.
Seismic ground motions induce torsional responses in buildings that can be difficult to predict. To compensate for this, most modern building codes require the consideration of accidental torsion when computing design earthquake forces. This study evaluates the influence of ASCE/SEI 7 accidental torsion seismic design requirements on the performance of 230 archetypical buildings that are designed with and without accidental torsion design provisions, taking building collapse capacity as the performance metric. The test case archetypes include a broad range of heights, gravity load levels, and plan configurations. Results show that the ASCE/SEI 7 accidental torsion provisions lead to significant changes in collapse capacity for buildings that are very torsionally flexible or asymmetric. However, only inconsequential changes in collapse capacity are observed in the buildings that are both torsionally stiff and regular in plan. Therefore, the study concludes that accidental torsion provisions are not necessary for seismic design of buildings without excessive torsional flexibility or asymmetry. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

12.
Study of the data from the extensively instrumented buildings in the 1987 Whittier Narrows earthquake suggests that torsional modes probably were excited in buildings that outwardly appear quite symmetric. Accordingly this study involves: (i) investigation of the observed response of two low-rise buildings in both the elastic and moderately inelastic domains, (ii) comparison of such behaviour with the results obtained from modelling studies, and (iii) examination of the possible effects arising from stronger shaking. The study was directed towards attempting to provide a partial answer to the critical question of whether or not the torsional response was important in the gross total response of these low-rise buildings, and to what extent torsional concepts should be considered in design. Also the numerical results were extrapolated to examine the survivability of the same buildings if subjected to a somewhat stronger earthquake. The ultimate goal was to contribute insight to the practical guidelines for design and analysis of low-rise buildings subjected to strong ground motion.  相似文献   

13.
This paper investigates the seismic response of multi‐storey cross‐laminated timber (CLT) buildings and its relationship with salient ground‐motion and building characteristics. Attention is given to the effects of earthquake frequency content on the inelastic deformation demands of platform CLT walled structures. The response of a set of 60 CLT buildings of varying number of storeys and panel fragmentation levels representative of a wide range of structural configurations subjected to 1656 real earthquake records is examined. It is shown that, besides salient structural parameters like panel aspect ratio, design behaviour factor, and density of joints, the frequency content of the earthquake action as characterized by its mean period has a paramount importance on the level of nonlinear deformations attained by CLT structures. Moreover, the evolution of drifts as a function of building to ground‐motion periods ratio is different for low‐ and high‐rise buildings. Accordingly, nonlinear regression models are developed for estimating the global and interstorey drifts demands on multi‐storey CLT buildings. Finally, the significance of the results is highlighted with reference to European seismic design procedures and recent assessment proposals.  相似文献   

14.
Seismic building codes include design provisions to account for the torsional effects arising in torsionally unbalanced (asymmetric) buildings. These provisions are based on two alternative analytical procedures for determining the design load for the individual resisting structural elements. A previous study has shown that the linear elastic modal analysis procedure may not lead to conservative designs, even for multistorey buildings with regular asymmetry, when such structures are excited well into the inelastic range of response. The equivalent static force procedure as recommended by codes may also be deficient in accounting for additional ductility demand in the critical stiff-edge elements. This paper addresses the non-conservatism of existing static torsional provisions and examines aspects of element strength distribution and its influence on inelastic torsional effects. A recommendation is made for improving the effectiveness of the code-type static force procedure for torsionally unbalanced multistorey frame buildings with regular asymmetry, leading to a design approach which estimates conservatively the peak ductility demand of edge elements on both sides of the building. The modified approach also retains the simplicity of existing code provisions and results in acceptable levels of additional lateral design strength. It has recently been adopted by the new Australian earthquake code, which is due to be implemented early in 1993.  相似文献   

15.
Discrepancies between the computed and actual values of the structural element stiffness imply that a building with nominally symmetric plan is actually asymmetric to some unknown degree and will undergo torsional vibration when subjected to purely translational ground motion. Such accidental torsion leads to increase in structural element deformations which is shown to be essentially insensitive to the uncoupled lateral vibration period of the system but is affected strongly by the ratio of uncoupled lateral and torsional vibration periods. The structural deformations increase, in the mean, by at most 10 and 5 per cent for R/C and steel buildings, respectively, and by much smaller amounts for a wide range of system parameters. The increase in structural deformations due to stiffness uncertainty is shown to be much smaller than implied by the accidental torsional provisions in the Uniform Building Code and most other building codes.  相似文献   

16.
For earthquake action the new design provisions of Eurocode 8 are in the process of replacing the European national earthquake codes. The paper treats the design and behaviour of multi-storey structural walls in view of the new provisions. For structural walls the provisions of the Eurocode 8 are compared with those of a national code which it is going to replace. As the national code the current Swiss earthquake standard SIA 160 is chosen. Basic design rules of both codes are introduced and compared by means of examples comprising buildings which are regular in plan and elevation and which use structural walls for lateral resistance. The height of the buildings is varied from a from four to eight storeys. In the example, both the SIA and the Eurocode design provisions are based on the static equivalent force method, and a triangular distribution of the lateral force. However, most other design provisions differ between the two codes. The structures designed are modelled numerically and subjected to non-linear time-history analysis. At first, both the SIA and Eurocode designed structures are subjected to ground motions compatible to the design spectra in the respective codes. Then all structures are subjected to a recorded ground motion. The results are discussed in view of assumptions made at the design phase. Conclusions and recommendations are provided. © 1998 John Wiley & Sons, Ltd.  相似文献   

17.
多维地震作用下非对称结构利用TLCD减震控制研究   总被引:5,自引:1,他引:5  
本文提出在结构两正交方向同时设置U形调液阻尼器(TLCD)用来减小地震作用下的平动-扭转反应,文中建立了结构-TLCD体系在多维地震动作用下的运动方程,分析了系统参数对减震效果的影响,最后通过数值算例,给出了高层建筑平扭耦联地震反应的减震效果。  相似文献   

18.
A study is presented of the influence of stiffness and strength eccentricities on the inelastic torsional response of buildings under the action of two simultaneous orthogonal horizontal ground motion components. Asymmetric buildings were obtained from their respective symmetric systems and were characterized by their stiffness and strength torsional eccentricities in both orthogonal directions. Based on the results of inelastic response of both building types (symmetric and asymmetric), the seismic reliability functions are determined for each system, and their forms of variation with different global system parameters are evaluated. Illustrative examples are presented about the use of this information for the formulation of seismic design criteria for in‐plan asymmetric multistory systems, in order to attain the same reliability levels implicit for symmetric systems designed in accordance with current seismic design codes. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

19.
With the aid of perturbation analysis of vibration frequencies and mode shapes it is shown that any lower vibration mode of a torsionally coupled building may be approximated as a linear combination of three vibration modes of the corresponding torsionally uncoupled system (a system with coincident centres of mass and resistance but all other properties are identical to the actual system): one translational mode along each of the two principal axes of resistance and one mode in torsional vibration. This result provides the motivation for a simpler—relative to the standard—procedure for analysing the response of torsionally coupled multistorey buildings to earthquake ground motion. To illustrate the application and accuracy of this procedure two numerical examples are presented.  相似文献   

20.
Active energy dissipation is proved to be very effective for abating seismic effects on buildings. The implementation of this concept in seismic design of buildings is studied by response simulations of a single storey building subjected to earthquake motion. Active energy dissipaters can be installed as part of the building lateral load bracing, and they regulate the strength and stiffness of the bracing during the building's response to the seismic events. The energy is dissipated when the bracing load exceeds the axial strength provided by the dissipater, and the bracing telescopes in and out. The design parameters of active energy dissipaters are described using the simulated response of a single storey building to ground pulse and harmonic ground excitation. The feasibility of the energy dissipater is demonstrated by the development and construction of a full-scale prototype device called an Active Slip Bracing Device (ASBD). The device utilizes Coulomb friction. The active characteristics are implemented by a computer controlled clamping mechanism on the friction interface. The ASBD's control of the strength and stiffness is investigated.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号