首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The results of shaking table tests of a series of 1:5 scale masonry building models have been used for the assessment of values of structural behavior factor q for masonry structures, seismic force reduction factors proposed for the calculation of design seismic loads by Eurocode 8, European standard for the design of structures for earthquake resistance. Six models have been tested, representing prototype buildings of two different structural configurations and built with two different types of masonry materials. The study indicated that the reduction of seismic forces for the design depends not only on the type of masonry construction system, but also on structural configuration and mechanical characteristics of masonry materials. It has been also shown that besides displacement and energy dissipation capacity, damage limitation requirement should be taken into account when evaluating the values of behavior factor. On the basis of analysis of experimental results a conclusion can be made, that the values at the upper limit of the proposed range of values of structural behavior factor q for unreinforced and confined masonry construction systems are adequate, if pushover methods are used and the calculated global ductility of the structure is compared with the displacement demand. In the case where elastic analysis methods are used and significant overstrength is expected, the proposed values are conservative. However, additional research and parametric studies are needed to propose the modifications.  相似文献   

2.
The seismic behavior of unreinforced masonry buildings is typically characterized by premature brittle collapse mechanisms that can cause serious consequences for the protection of human lives and for the preservation of historical and cultural heritage. Structural health monitoring can be a powerful tool enabling a quick post-earthquake assessment of the structure's performance, but its applications are still scarce as a consequence of the severe limitations affecting off-the-shelf sensing technologies, in terms of local nature of the measurements, costs, as well as long-term behavior, installation, and maintenance. To overcome some of these limitations, the authors have recently proposed a new sensing technology, called “smart brick,” that is a durable clay brick doped with stainless steel microfibers, working as a smart strain sensor for masonry buildings. This paper presents the first full-scale application of smart bricks, used for detecting and localizing progressive earthquake-induced damage in an unreinforced masonry building subjected to shaking table tests. Smart bricks are employed to detect changes in load paths on masonry walls, comparing strain measurements acquired after each step of the seismic sequence with those referring to the undamaged structure. Experimental results are interpreted using a 3D finite element model built to reproduce the shaking table tests. Overall, the results demonstrate that the smart bricks can effectively reveal local permanent changes in structural conditions following a progressive damage, therefore being apt for earthquake-induced damage detection and localization.  相似文献   

3.
This study focuses on the evaluation of seismic safety of unreinforced masonry buildings in Turkey by using fragility curves generated for two behavior modes of load bearing walls: in-plane and out-of-plane. During generation of fragility curves, a force-based approach has been used. There exist two limit states in terms of base shear strength for in-plane behavior mode and flexural strength for out-of-plane behavior mode. To assess the seismic vulnerability of unreinforced masonry buildings in Turkey, fragility curves generated for in-plane behavior were verified by the observed damage during the 1995 Dinar (Turkey) earthquake and fragility curves generated for out-of-plane behavior were verified by the observed damage during the 2010 Elaz?? (Turkey) earthquake. The verification results reveal that the proposed fragility-based procedure can provide an alternative for the seismic safety evaluation of unreinforced masonry buildings in Turkey. Using this procedure, it becomes possible to investigate a large population of masonry buildings located in regions of high seismic risk in a short period of time. The obtained results are valuable in the sense that they can be used as a database during the development of strategies for pre-earthquake planning and risk mitigation for earthquake prone regions of Turkey.  相似文献   

4.
This paper presents a masonry panel model for the nonlinear static and dynamic analysis of masonry buildings suitable for the seismic assessment of new and existing structures. The model is based on an equivalent frame idealization of the structure and stems from previous research on force‐based frame elements. The element formulation considers axial, bending, and shear deformations within the framework of the Timoshenko beam theory. A phenomenological cyclic section law that accounts for the shear panel response is coupled, through equilibrium between shear and bending forces along the element, with a fiber‐section model that accounts for the axial and bending responses. The proposed panel model traces with a low computational burden and numerical stability the main aspects of the structural behavior of masonry panels and is suitable for analyses of multi‐floor buildings with a relatively regular distribution of openings and with walls and floors organized to grant a box‐like behavior under seismic loads. The model capabilities are validated though analyses of simple unreinforced masonry panels and comparisons with published experimental results. The model accuracy is strongly dependent on the fiber and shear constitutive laws used. However, the formulation is general, and laws different from those employed in this study are easily introduced without affecting the model formulation. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

5.
单体建筑无筋砌体结构的抗震韧性较差,在地震中容易发生严重破坏和倒塌。为此,以抗震韧性为参数指标,对单体无筋砌体结构进行加固并分析,研究其在地震作用下的抗震能力。以某实际工程作为研究对象,运用ANSYS软件建立单体建筑无筋砌体加固有限元模型,选取中国汶川地震波、日本阪神大地震波、美国克恩县地震波、中国台湾集集地震波及人工地震波作为地震动输入,利用韧性指数法和韧性等级法,从无筋砌体加固体系在震后的修复费用、修复时间及人员伤亡等方面进行分析,得到抗震韧性评估结果。研究表明:(1)在罕遇地震、设防地震和多遇地震的情况下,单体建筑无筋砌体结构的层间位移、层间剪应力、破坏程度均大于单体建筑无筋砌体加固体系;(2)在受到地震强弱因素影响下,无筋砌体结构的抗震韧性指数最高为0.877,而其加固体系的抗震韧性指数最低为0.908;(3)在经历不同地震波后,无筋砌体结构受到较大损害等级占比较高,人员伤亡较重,需要花费较长的时间和较多的费用完成灾后重建;而经过加固后的无筋砌体结构,加固体系受到较小损害等级占比较高,人员伤亡较轻,且能够用较短的时间和较少的费用完成灾后重建。  相似文献   

6.
For seismic analysis of unreinforced masonry (URM) buildings characterized by a box-like behavior, a widely accepted model is based on the equivalent frame idealization of walls. The equivalent frame model uses 1D elements to represent the vertical piers and horizontal spandrels which are connected by rigid nodes. The mechanical characterization of the elements is one of the crucial aspects to predict reasonably the building seismic behavior. Through the comparison with pseudo-static and dynamic experimental tests performed on two-story full-scale buildings, this paper validates the frame modeling in the OpenSees framework, which includes a fiber-section force-based beam element for the axial-flexural behavior, coupled with a cyclic shear-deformation phenomenological law.  相似文献   

7.
This paper presents the results of an experimental investigation carried out to investigate the seismic performance of a two storey brick masonry house with one room in each floor. A half‐scale building constructed using single wythe clay brick masonry laid in cement sand mortar and a conventional timber floor and timber roof clad with clay tiles was tested under earthquake ground motions on a shaking table, first in the longitudinal direction and then in the transverse direction. In each direction, the building was subjected to different ground motions with gradually increasing intensity. Dynamic properties of the system were assessed through white‐noise tests after each ground motion. The building suffered increasing levels of damage as the excitations became more severe. The damage ranged from cracking to global/local rocking of different piers and partial out‐of‐plane failure of the walls. Nevertheless, the building did not collapse under base excitations with peak ground acceleration up to 0.8g. General behaviour of the tested building model during the tests is discussed, and fragility curves are developed for unreinforced masonry buildings based on the experimental results. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

8.
Seismic assessment of existing unreinforced masonry buildings represents a current challenge in structural engineering. Many historical masonry buildings in earthquake regions were not designed to withstand seismic loading; thus, these structures often do not meet the basic safety requirements recommended by current seismic codes and need to be strengthened considering the results from realistic structural analysis. This paper presents an efficient modelling strategy for representing the nonlinear response of unreinforced masonry components under in‐plane cyclic loading, which can be used for practical and accurate seismic assessment of masonry buildings. According to the proposed strategy, generic masonry perforated walls are modelled using an equivalent frame approach, where each masonry component is described utilising multi‐spring nonlinear elements connected by rigid links. When modelling piers and spandrels, nonlinear springs are placed at the two ends of the masonry element for describing the flexural behaviour and in the middle for representing the response in shear. Specific hysteretic rules allowing for degradation of stiffness and strength are then used for modelling the member response under cyclic loading. The accuracy and the significant potential of the proposed modelling approach are shown in several numerical examples, including comparisons against experimental results and the nonlinear dynamic analysis of a building structure. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

9.
The three-dimensional non-linear earthquake behaviour of unreinforced masonry buildings is studied by using a constitutive model established experimentally for burned-clay brick masonry wall panels. The parameter functions appearing in the constitutive model are modified so that they accommodate a wall panel made of a general masonry material. In the study it is assumed that the floors of the masonry building are reinforced concrete slabs which are infinitely rigid in their own planes and that the wall panels possess only in-plane rigidities. Some examples involving earthquake analyses of two different masonry structures are presented. It is found that the predictions of the model used in the study are in harmony with the experimental data available in the literature.  相似文献   

10.
Many older unreinforced masonry (URM) buildings feature timber floors and solid brick masonry. Simple equivalent frame models can help predicting the expected failure mechanism and estimating the strength of a URM wall. When modelling a URM wall with an equivalent frame model rather than, for example, a more detailed simplified micro-model, the strengths of the piers and spandrels need to be estimated from mechanical or empirical models. Such models are readily available for URM piers, which have been tested in many different configurations. On the contrary, only few models for spandrel strength have been developed. This paper reviews these models, discusses their merits, faults and compares the predicted strength values to the results of recent experimental tests on masonry spandrels. Based on this assessment, the paper outlines recommendations for a new set of strength equations for masonry spandrels.  相似文献   

11.
Several factors influence the behaviour of infilled frames, which have been a subject of research in the past with moderate success. The new generation of European design standards imposes the need to prevent brittle collapse of the infills and makes the structural engineer accountable for this requirement, yet it fails to provide sufficient information for masonry infills design. Therefore, the present work aims at understanding the seismic behaviour of masonry infill walls within reinforced concrete frames, using both unreinforced and reinforced solutions (bed joint reinforcement and reinforced plaster). For this purpose, three reinforced concrete buildings with different infill solutions were constructed at a scale of 1:1.5, all with the same geometry, and were tested on the shaking table of the National Laboratory for Civil Engineering, Portugal. All solutions performed adequately for the design earthquake, with no visible damage. Still, the experimental tests show that the double‐leaf‐unreinforced infill walls underperformed during a large earthquake, collapsing out of plane by rotating as rigid bodies with multiple configurations. Also the reinforced concrete buildings collapsed, because of the adverse interaction with the infill walls. The infill walls with bed joint reinforcement and reinforced plaster did not collapse out of plane, because of their connection to the concrete frame, which is an essential requirement. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

12.
Reinforced concrete (RC) buildings in Nepal are constructed with RC frames and masonry infill panels. These structures exhibit a highly non-linear inelastic behavior resulting from the interaction between the panels and frames. This paper presents an extensive case study of existing RC buildings in Nepal. Non-linear analyses were performed on structural models of the buildings considered as a bare frame and with masonry infill, in order to evaluate the influence of infill walls on the failure mechanisms. Five three-storey buildings with different structural configurations and detailing were selected. The effect of masonry infill panels on structural response was delineated by comparing the bare-framed response with the infill response. Seismic performance is evaluated with regard to global strength, stiffness, energy dissipation, inter-storey drift, and total deflection of the structure. A parametric analysis of structures with masonry infill is also performed. For this, the influence of different material properties is studied, namely diagonal compressive stress, modulus of elasticity and tensile stress of masonry infill panels. Study results show that masonry infill increases the global strength and stiffness of the structures; it decreases the inter-storey drift and hence the total displacement of the structure. The results quantify the influence of the infill panels on structural response and, in particular, the effect of the diagonal compressive strength of the masonry wall.  相似文献   

13.
Typical low-rise masonry buildings consist of unreinforced masonry (URM) walls covered with various timber roof configurations generally supported or finished by masonry gables. Post-earthquake observations and experimental outcomes highlighted the large vulnerability of the URM gables to the development of overturning mechanisms, both because of the inertial out-of-plane excitation and the in-plane timber diaphragm deformability. This paper presents the static and dynamic experimental seismic performance of three full-scale roofs tested via quasi-static cyclic and shake table tests. Two of them were tested as part of a whole full scale one-storey and two-storey building. A single-degree-of-freedom (SDOF) numerical model is calibrated against experimental data and proposed for the analysis of this roof typology's dynamic behaviour. Several sets of analyses were conducted to assess the vulnerability of these structural components and to study the effect of the whole building's characteristics (eg, number of storeys and structural stiffness and strength) on the seismic performance of this roof typology.  相似文献   

14.
15.
Seismic performance of a three-storey unreinforced masonry building which survived the 1992 Erzincan earthquake without damage is evaluated. Mechanical properties of the masonry walls have been determined experimentally by using identical brick and mortar used in construction. An accurate material model is developed for masonry and employed in a computer program for the non-linear dynamic analysis of masonry buildings. The analytical results based on measured material properties indicated that masonry buildings which satisfy basic seismic code requirements possess remarkable lateral strength, stiffness and energy dissipation capacity. Accordingly, a simple elastic design approach is rendered suitable for unreinforced masonry under seismic excitations, provided that realistic material properties are employed in design.  相似文献   

16.
When testing multi-storey structures, most testing facilities require the testing of a reduced-scale model. A literature review on tests of scaled masonry structural components revealed that scaling of masonry was rather challenging and often significant differences in stiffness, strength and failure mechanisms between the different sized masonry were reported. This paper addresses the scaling of hollow clay brick masonry with fully mortared head and bed joints. We investigate different choices of scaling brick units and mortar joints. Based on the results of an extensive test programme including standard material tests and quasi-static cyclic tests on masonry walls subjected to horizontal and axial loads, we formulate recommendations for the production of a half-scale model of unreinforced masonry structures. The experimental results show a good match between full-scale and half-scale masonry. We discuss the differences in material properties that remained and compare the force-displacement hystereses obtained for the wall tests.  相似文献   

17.
Recent major earthquakes around the world have evidenced that research in earthquake engineering must be directed to the vulnerability assessment of existing constructions lacking appropriate seismic resisting characteristics. Their retrofit or replacement should be made in order to reduce vulnerability, and consequent risk, to currently accepted levels. In this work, the efficiency of ductile steel eccentrically-braced systems in the seismic retrofitting of existing reinforced concrete (RC) buildings is studied. The retrofit technique studied consists in a bracing system with an energy dissipation device, designed to dissipate energy by shear deformation. The numerical model was calibrated with cyclic test results on a full-scale structure. The models used for the RC frame and masonry represent their real behavior and influence in the global structural response. The steel bracing system was modeled with strut rigid elements. The model for the energy dissipater device reproduces rigorously the behavior of the shear-link observed in the cyclic tests, namely in terms of shear, drift and energy dissipation. With the calibrated numerical model, a series of non-linear dynamic analyses were performed, for different earthquake input motions, intending to study: the influence of the retrofitting system in the response of bare and infilled structures; the influence of the location and strength of the retrofitting system.  相似文献   

18.
Seismic behaviour of masonry buildings, built of low compressive strength units, is discussed. Although such materials have already been tested and approved for use from mechanical and thermal insulation point of view, the knowledge regarding their structural behaviour is still lacking. In order to investigate the resistance and deformation capacity of this particular type of masonry construction in seismic conditions, a series of eight walls and model of a two-storey full scale confined masonry building have been tested by subjecting the specimens to cyclic shear loads. All tests were conducted under a combination of constant vertical load and quasi static, cyclically imposed horizontal load. The behaviour of tested specimens was of typical shear type. Compared with the behaviour of plain masonry walls, the presence of tie-columns resulted into higher resistance and displacement capacity, as well as smaller lateral resistance degradation. The response of the model was determined by storey mechanism with predominant shear behaviour of the walls and failure mechanism of the same type as in the case of individual confined masonry walls. Adequate seismic behaviour of this particular masonry structural type can be expected under the condition that the buildings are built as confined masonry system with limited number of stories.  相似文献   

19.
利用ABAQUS软件对既有的砌体墙试验结果进行了数值模拟,验证了模型的正确性以及混凝土损伤塑性模型对模拟砌体结构受力性能的可用性。在此基础上,借助实地调查获得的结构参数和材料性能数据,以重庆典型农居建筑为例,建立了无筋砌体农居的三维有限元模型,对数值模型进行了动力特性分析和不同烈度下多遇及罕遇地震的动力弹塑性时程分析,并建议了无筋砌体结构农居在不同地震烈度破坏下墙体表面积受拉损伤率的临界值。最后,利用既有文献提出的层间位移角限值,分析了该农居的破坏程度,比较了墙体表面积受拉损伤率和层间位移角限值衡量砌体结构的破坏程度。分析结果表明:提出的墙体表面积受拉损伤率和层间位移角限值衡量砌体结构破坏程度吻合良好;当墙体表面积受拉损伤率小于1%时,结构轻微破坏;当位于1%~5%时,发生中等程度破坏;当位于5%~30%时,发生严重破坏;当大于30%时,结构倒塌。  相似文献   

20.
Seismic response of unreinforced masonry (URM) buildings is largely influenced by nonlinear behavior of spandrels, which provide coupling between piers under in‐plane lateral actions. Seismic codes do not appropriately address modeling and strength verification of spandrels, adapting procedures originally proposed for piers. Therefore, research on spandrels has received significant attention in some earthquake‐prone countries, such as Italy and New Zealand. In the last years, the authors of this paper have performed both monotonic and cyclic in‐plane lateral loading tests on full‐scale masonry walls with single opening and different spandrel types. Those tests were carried out in a static fashion and with displacement control. In this paper, experimental outcomes for two as‐built specimens are presented and compared with those obtained in the past for another as‐built specimen with a wooden lintel above the opening. In both newly tested specimens, the masonry above the opening was supported by a shallow masonry arch. In one of those specimens, a reinforced concrete (RC) bond beam was realized on top of the spandrel, resulting in a composite URM‐RC spandrel. Then, the influence of spandrel type is analyzed in terms of observed damage, force–drift curves, and their bilinear idealizations, which allowed to compare displacement ductility and overstrength of wall specimens. Furthermore, effects of rocking behavior of piers are identified, highlighting their relationship with hysteretic damping and residual drifts. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   