1.
This paper explores the relationship between thermal energy and fresh water recoveries from an aquifer storage recovery (ASR) well in a brackish confined aquifer. It reveals the spatial and temporal distributions of temperature and conservative solutes between injected and recovered water. The evaluation is based on a review of processes affecting heat and solute transport in a homogeneous aquifer. In this simplified analysis, it is assumed that the aquifer is sufficiently anisotropic to inhibit density‐affected flow, flow is axisymmetric, and the analysis is limited to a single ASR cycle. Results show that the radial extent of fresh water at the end of injection is greater than that of the temperature change due to the heating or cooling of the geological matrix as well as the interstitial water. While solutes progress only marginally into low permeability aquitards by diffusion, conduction of heat into aquitards above and below is more substantial. Consequently, the heat recovery is less than the solute recovery when the volume of the recovered water is lower than the injection volume. When the full volume of injected water is recovered the temperature mixing ratio divided by the solute mixing ratio for recovered water ranges from 0.95 to 0.6 for ratios of maximum plume radius to aquifer thickness of 0.6 to 4.6. This work is intended to assist conceptual design for dual use of ASR for conjunctive storage of water and thermal energy to maximize the potential benefits.  相似文献   

2.
In the Western United States, demand for water is often out of balance with limited water supplies. This has led to extensive water rights conflict and litigation. A tool that can reliably forecast natural aquifer discharge months ahead of peak water demand could help water practitioners and managers by providing advanced knowledge of potential water‐right mitigation requirements. The timing and magnitude of natural aquifer discharge from the Eastern Snake Plain Aquifer (ESPA) in southern Idaho is accurately forecast 4 months ahead of the peak water demand, which occurs annually in July. An ARIMA time‐series model with exogenous predictors (ARIMAX model) was used to develop the forecast. The ARIMAX model fit to a set of training data was assessed using Akaike's information criterion to select the optimal model that forecasts aquifer discharge, given the previous year's discharge and values of the predictor variables. Model performance was assessed by application of the model to a validation subset of data. The Nash‐Sutcliffe efficiency for model predictions made on the validation set was 0.57. The predictor variables used in our forecast represent the major recharge and discharge components of the ESPA water budget, including variables that reflect overall water supply and important aspects of water administration and management. Coefficients of variation on the regression coefficients for streamflow and irrigation diversions were all much less than 0.5, indicating that these variables are strong predictors. The model with the highest AIC weight included streamflow, two irrigation diversion variables, and storage.  相似文献   

3.
A mathematical model is developed for predicting the temperature distribution in an aquifer thermal energy storage (ATES) system, which consists of a confined aquifer bounded from above and below by the rocks of different geological properties. The main transfer processes of heat include the conduction and advection in the aquifer and the conduction in the rocks. The semi‐analytical solution in dimensionless form for the model is developed by Laplace transforms and its corresponding time‐domain solution is evaluated by the modified Crump method. Field geothermal property data are used to simulate the temperature distribution in an ATES system. The results show that the heat transfer in the aquifer is fast and has a vast effect on the vicinity of the wellbore. However, the aquifer temperature decreases with increasing radial and vertical distances. The temperature in the aquifer may be overestimated when ignoring the effect of thermal conductivity. The temperature distribution in an ATES system depends on the vertical thermal conduction in the rocks and the horizontal advection and thermal conduction in the aquifer. The present solution is useful in designing and simulating the heat injection facility in the ATES systems. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

4.
Temperature is often used to infer the effect of land use and climate conditions on aquifers. Reliable data are needed to examine the temperature behaviour in the subsurface; thus, the use of robust acquisition techniques is unavoidable. Three temperature measurement techniques were applied to assess the sources of bias that could occur during temperature logging in a shallow Quaternary coastal aquifer in Ferrara (Northern Italy). Open borehole temperature logging, multilevel sampling straddle packers isolated temperature measurements within a flow cell above ground and multilevel sampling straddle packers isolated temperature measurements via an in‐well level logger (MLS‐IW) were compared for several coastal monitoring wells to gain insights on the limitations of each technique. Results show that the source of bias between the three applied techniques are different: (i) the open borehole temperature logging method tends to record heat convection through the open borehole and is not representative of the aquifer temperature distribution; (ii) the multilevel sampling straddle packers isolated temperature measurements within a flow cell above ground method is swayed by the air temperature and the heating of the submersible pump used to lift groundwater above ground; and (iii) the MLS‐IW provides the most reliable vertical thermal profiling both in summer and winter, because groundwater temperature is directly measured at the selected monitoring depth. The implementation of a 1D flow model demonstrates that if precise temperature profiles are needed to infer the influence that land use and climate changes have on groundwater, the MLS‐IW method is a reliable method that could be applied to existing monitoring wells. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

5.
Long‐term heating of shallow urban aquifers is observed worldwide. Our measurements in the city of Cologne, Germany revealed that the groundwater temperatures found in the city centre are more than 5 K higher than the undisturbed background. To explore the role of groundwater flow for the development of subsurface urban heat islands, a numerical flow and heat transport model is set up, which describes the hydraulic conditions of Cologne and simulates the transient evolution of thermal anomalies in the urban ground. A main focus is on the influence of horizontal groundwater flow, groundwater recharge and trends in local ground warming. To examine heat transport in groundwater, a scenario consisting of a local hot spot with a length of 1 km of long‐term ground heating was set up in the centre of the city. Groundwater temperature‐depth profiles at upstream, central and downstream locations of this hot spot are inspected. The simulation results indicate that the main thermal transport mechanisms are long‐term vertical conductive heat input, horizontal advection and transverse dispersion. Groundwater recharge rates in the city are low (<100 mm a?1) and thus do not significantly contribute to heat transport into the urban aquifer. With groundwater flow, local vertical temperature profiles become very complex and are hard to interpret, if local flow conditions and heat sources are not thoroughly known. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

6.
An approach is presented to determine the seasonal variations in travel time in a bank filtration system using a passive heat tracer test. The temperature in the aquifer varies seasonally because of temperature variations of the infiltrating surface water and at the soil surface. Temperature was measured with distributed temperature sensing along fiber optic cables that were inserted vertically into the aquifer with direct push equipment. The approach was applied to a bank filtration system consisting of a sequence of alternating, elongated recharge basins and rows of recovery wells. A SEAWAT model was developed to simulate coupled flow and heat transport. The model of a two‐dimensional vertical cross section is able to simulate the temperature of the water at the well and the measured vertical temperature profiles reasonably well. MODPATH was used to compute flowpaths and the travel time distribution. At the study site, temporal variation of the pumping discharge was the dominant factor influencing the travel time distribution. For an equivalent system with a constant pumping rate, variations in the travel time distribution are caused by variations in the temperature‐dependent viscosity. As a result, travel times increase in the winter, when a larger fraction of the water travels through the warmer, lower part of the aquifer, and decrease in the summer, when the upper part of the aquifer is warmer.  相似文献   

7.
To better understand the groundwater resources of southern Nye County, Nevada, a multipart distributed thermal perturbation sensing (DTPS) test was performed on a complex of three wells. These wells penetrate an alluvial aquifer that drains the Nevada National Security Site, and characterizing the hydraulic properties and flow paths of the regional groundwater flow system has proven very difficult. The well complex comprised one pumping well and two observation wells, both located 18 m from the pumping well. Using fiber‐optic cables and line heaters, DTPS tests were performed under both stressed and unstressed conditions. Each test injects heat into the water column over a period of one to two days, and observes the rising temperature during heat injection and falling temperatures after heating ceases. Aquifer thermal properties are inferred from temperature patterns in the cased section of the wells, and fluxes through the 30‐m screened section are estimated based on a model that incorporates conductive and advective heat fluxes. Vertical variations in flux are examined on a scale of tens of cm. The actively flowing zones of the aquifer change between the stressed and unstressed test, and anisotropy in the aquifer permeability is apparent from the changing fluxes between tests. The fluxes inferred from the DTPS tests are compared to solute tracer tests previously performed on the same site. The DTPS‐based fluxes are consistent with the fastest solute transport observed in the tracer test, but appear to overestimate the mean flux through the system.  相似文献   

8.
Quantifying groundwater flow at seepage faces is crucial because seepage faces influence the hydroecology and water budgets of watersheds, lakes, rivers and oceans, and because measuring groundwater fluxes directly in aquifers is extremely difficult. Seepage faces provide a direct and measurable groundwater flux but there is no existing method to quantitatively image groundwater processes at this boundary. Our objective is to determine the possibilities and limitations of thermal imagery in quantifying groundwater discharge from discrete seeps. We developed a conceptual model of temperature below discrete seeps, observed 20 seeps spectacularly exposed in three dimensions at an unused limestone quarry and conducted field experiments to examine the role of diurnal changes and rock face heterogeneity on thermal imagery. The conceptual model suggests that convective air‐water heat exchange driven by temperature differences is the dominant heat transfer mechanism. Thermal imagery is effective at locating and characterizing the flux of groundwater seeps. Areas of active groundwater flow and ice growth can be identified from thermal images in the winter, and seepage rates can be differentiated in the summer. However, the application of thermal imagery is limited by diverse factors including technical issues of image acquisition, diurnal changes in radiation and temperature, and rock face heterogeneity. Groundwater discharge rates could not be directly quantified from thermal imagery using our observations but our conceptual model and experiments suggest that thermal imagery could quantify groundwater discharge when there are large temperature differences, simple cliff faces, non‐freezing conditions, and no solar radiation.  相似文献   

9.
A recent study assessing the state‐of‐the‐practice of in situ thermal remediation technologies (e.g., electrical resistive heating [ERH], conductive heating, steam‐based heating, in situ large‐diameter auger soil mixing with steam/hot air injection, and radio‐frequency heating) identified 182 applications in the 1988 to 2007 period and summarized the geologic settings in which these technologies were applied, chemicals treated, design parameters, and operating conditions. That study concluded that documentation for less than 8% of those applications contained sufficient data to assess the effect remediation had on groundwater quality. Consequently, post‐treatment data were collected at five ERH sites, with emphasis on assessing reductions in dissolved groundwater concentrations and mass discharge (mass flux) to the aquifer. For each site, dissolved groundwater concentrations and hydraulic conductivities were determined across a vertical transect oriented perpendicular to groundwater flow and at the downgradient edge of the treatment zone. Dissolved concentration and mass discharge reductions ranged from about less than 10× to 100×, with post‐treatment groundwater concentrations ranging from about 101 to 104μg/L and mass discharges ranging from about 101 to 102 kg/y. The primary factors differentiating sites with greater and lesser dissolved concentration and mass discharge reductions were the adequacy of pre‐treatment source zone delineation, the extent to which the treatment zone encompassed the source zone, and the duration of treatment at the design operating temperature. The results suggest that ERH systems are capable of reducing groundwater concentrations to 10 to 100 μg/L levels and lower in some settings, but only if the source zone is adequately delineated and fully encompassed by the treatment system, and the treatment system is operated for a sufficiently long period of time.  相似文献   

10.
Analysis of the vapor in passive vapor samplers retrieved from a streambed in fractured rock terrain implied that volatile organic carbon (VOC) discharge from ground water to surface water substantially increased following installation of a contaminant recovery well using air rotary drilling. The air rotary technique forced air into the aquifer near the stream. The injection produced an upward hydraulic gradient that appears to have transported water and contaminants from deeper parts of the aquifer through fractures into shallow parts of the aquifer. Once in the shallow flow regime, the contamination was transported to the stream, where it discharged during the next several weeks following well installation. After the recovery well was activated and began continuously pumping contaminated ground water to a treatment facility, the VOC concentrations in the stream bottom passive vapor samplers decreased to below detectable concentrations, suggesting that the withdrawal had captured the contaminated ground water that previously had discharged to the stream.  相似文献   

11.
In this study, we examine the maximum net extraction rate from the novel arrangement of an injection‐extraction well pair in a coastal aquifer, where fresh groundwater is reinjected through the injection well located between the interface toe and extraction well. Complex potential theory is employed to derive a new analytical solution for the maximum net extraction rate and corresponding stagnation‐point locations and recirculation ratio, assuming steady‐state, sharp‐interface conditions. The injection‐extraction well‐pair system outperforms a traditional single extraction well in terms of net extraction rate for a broad range of well placement and pumping rates, which is up to 50% higher for an aquifer with a thickness of 20 m, hydraulic conductivity of 10 m/d, and fresh water influx of 0.24 m2/d. Sensitivity analyses show that for a given fresh water discharge from an inland aquifer, a larger maximum net extraction is expected in cases with a smaller hydraulic conductivity or a smaller aquifer thickness, notwithstanding physical limits to drawdown at the pumping well that are not considered here. For an extraction well with a fixed location, the optimal net extraction rate linearly increases with the distance between the injection well and the sea, and the corresponding injection rate and recirculation ratio also increase. The analytical analysis in this study provides initial guidance for the design of well‐pair systems in coastal aquifers, and is therefore an extension beyond previous applications of analytical solutions of coastal pumping that apply only to extraction or injection wells.  相似文献   

12.
Interaction between groundwater and surface water in watersheds has significant impacts on water management and water rights, nutrient loading from aquifers to streams, and in‐stream flow requirements for aquatic species. Of particular importance are the spatial patterns of these interactions. This study explores the spatio‐temporal patterns of groundwater discharge to a river system in a semi‐arid region, with methods applied to the Sprague River Watershed (4100 km2) within the Upper Klamath Basin in Oregon, USA. Patterns of groundwater–surface water interaction are explored throughout the watershed during the 1970–2003 time period using a coupled SWAT‐MODFLOW model tested against streamflow, groundwater level and field‐estimated reach‐specific groundwater discharge rates. Daily time steps and coupling are used, with groundwater discharge rates calculated for each model computational point along the stream. Model results also are averaged by month and by year to determine seasonal and decadal trends in groundwater discharge rates. Results show high spatial variability in groundwater discharge, with several locations showing no groundwater/surface water interaction. Average annual groundwater discharge is 20.5 m3/s, with maximum and minimum rates occurring in September–October and March–April, respectively. Annual average rates increase by approximately 0.02 m3/s per year over the 34‐year period, negligible compared with the average annual rate, although 70% of the stream network experiences an increase in groundwater discharge rate between 1970 and 2003. Results can assist with water management, identifying potential locations of heavy nutrient mass loading from the aquifer to streams and ecological assessment and planning focused on locations of high groundwater discharge. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

13.
Heat was used as a tracer to measure infiltration rates from a recharge basin. The propagation of diurnal oscillation of surface water temperature into the basin bed was monitored along a transect using Fiber Optic Distributed Temperature Sensing (FODTS). The propagation rate was related to downward specific discharge using standard theory of heat advection and dispersion in saturated porous media. An estimate of the temporal variation of heat propagation was achieved using a wavelet transform to find the phase lag between the surface temperature diurnal oscillation and the correlated oscillation at 0.33 and 0.98 m below the bed surface. The wavelet results compared well to a constant velocity model of thermal advection and dispersion during periods of relatively constant discharge rates. The apparent dispersion of heat was found to be due primarily to hydrodynamic mechanisms rather than thermal diffusion. Specific discharge estimates using the FODTS technique also compared well to water balance estimates over a four month period, although there were occasional deviations that have yet to be adequately explained. The FODTS technique is superior to water balance in that it produces estimates of infiltration rate every meter along the cable transect, every half hour. These high resolution measurements highlighted areas of low infiltration and demonstrated the degradation of basin efficiency due to source waters of high suspended solids. FODTS monitoring promises to be a useful tool for diagnosing basin performance in an era of increasing groundwater demand.  相似文献   

14.
The hydrology of a small wet forested region is studied. Catchment discharge, solar radiation, air temperature, humidity, precipitation, soil moisture, and the water elevation in a swamp were monitored for several months in 1973 and 1975. These data are used to investigate various aspects of the catchment's hydrology and in particular to study the catchment's evapotranspirational requirements. The actual evapotranspiration loss is calculated from a water budget approach. The Priestley-Taylor model is used to predict the medium to long-term evapotranspiration from the basin. The predictions based on the model are in very good agreement with the actual evapotranspirational demand. Evapotranspiration is found to play a significant role in the catchment's water balance.  相似文献   

15.
Stream-water temperature is a key variable controlling chemical, biological, and ecological processes in freshwater environments. Most models focus on a single river cross-section; however, temperature gradients along stretches and tributaries of a river network are crucial to assess ecohydrological features such as aquatic species suitability, growth and feeding rates, or disease transmission. We propose SESTET, a deterministic, spatially explicit stream temperature model for a whole river network, based on water and energy budgets at a reach scale and requiring only commonly available spatially distributed datasets, such as morphology and air temperature, as input. Heat exchange processes at the air–water interface are modelled via the widely used equilibrium temperature concept, whereas the effects of network structure are accounted for through advective heat fluxes. A case study was conducted on the prealpine Wigger river (Switzerland), where water temperatures have been measured in the period 2014–2018 at 11 spatially distributed locations. The results show the advantages of accounting for water and energy budgets at the reach scale for the entire river network, compared with simpler, lumped formulations. Because our approach fundamentally relies on spatially distributed air temperature fields, adequate spatial interpolation techniques that account for the effects of both elevation and thermal inversion in air temperature are key to a successful application of the model. SESTET allows the assessment of the magnitude of the various components of the heat budget at the reach scale and the derivation of reliable estimates of spatial gradients of mean daily stream temperatures for the whole catchment based on a limited number of conveniently located (viz., spanning the largest possible elevation range) measuring stations. Moreover, accounting for mixing processes and advective fluxes through the river network allows one to trust regionalized values of the parameters controlling the relationship between equilibrium and air temperature, a key feature to generalize the model to data-scarce catchments.  相似文献   

16.
The transition area between rivers and their adjacent riparian aquifers, which may comprise the hyporheic zone, hosts important biochemical reactions, which control water quality. The rates of these reactions and metabolic processes are temperature dependent. Yet the thermal dynamics of riparian aquifers, especially during flooding and dynamic groundwater flow conditions, has seldom been studied. Thus, we investigated heat transport in riparian aquifers during 3 flood events of different magnitudes at 2 sites along the same river. River and riparian aquifer temperature and water‐level data along the Lower Colorado River in Central Texas, USA, were monitored across 2‐dimensional vertical sections perpendicular to the bank. At the downstream site, preflood temperature penetration distance into the bank suggested that advective heat transport from lateral hyporheic exchange of river water into the riparian aquifer was occurring during relatively steady low‐flow river conditions. Although a small (20‐cm stage increase) dam‐controlled flood pulse had no observable influence on groundwater temperature, larger floods (40‐cm and >3‐m stage increases) caused lateral movement of distinct heat plumes away from the river during flood stage, which then retreated back towards the river after flood recession. These plumes result from advective heat transport caused by flood waters being forced into the riparian aquifer. These flood‐induced temperature responses were controlled by the size of the flood, river water temperature during the flood, and local factors at the study sites, such as topography and local ambient water table configuration. For the intermediate and large floods, the thermal disturbance in the riparian aquifer lasted days after flood waters receded. Large floods therefore have impacts on the temperature regime of riparian aquifers lasting long beyond the flood's timescale. These persistent thermal disturbances may have a significant impact on biochemical reaction rates, nutrient cycling, and ecological niches in the river corridor.  相似文献   

17.
Karst spring responses examined by process-based modeling   总被引:8,自引:0,他引:8  
Birk S  Liedl R  Sauter M 《Ground water》2006,44(6):832-836
Ground water in karst terrains is highly vulnerable to contamination due to the rapid transport of contaminants through the highly conductive conduit system. For contamination risk assessment purposes, information about hydraulic and geometric characteristics of the conduits and their hydraulic interaction with the fissured porous rock is an important prerequisite. The relationship between aquifer characteristics and short-term responses to recharge events of both spring discharge and physicochemical parameters of the discharged water was examined using a process-based flow and transport model. In the respective software, a pipe-network model, representing fast conduit flow, is coupled to MODFLOW, which simulates flow in the fissured porous rock. This hybrid flow model was extended to include modules simulating heat and reactive solute transport in conduits. The application of this modeling tool demonstrates that variations of physicochemical parameters, such as solute concentration and water temperature, depend to a large extent on the intensity and duration of recharge events and provide information about the structure and geometry of the conduit system as well as about the interaction between conduits and fissured porous rock. Moreover, the responses of solute concentration and temperature of spring discharge appear to reflect different processes, thus complementing each other in the aquifer characterization.  相似文献   

18.
Detailed monitoring of surface atmospheric and subterranean microclimatic conditions has provided a new opportunity to interpret drip water temperature changes associated with climate variability. High-resolution multi-index monitoring was conducted in Xiaoyan Cave, Guilin, southwest China, for a period of four years (2011–2014) to identify the processes that control drip water temperature. The results show that variations in drip water temperature are mainly coupled to changes in the cave air temperature unless large drip discharge occurs. The controls on cave air temperature depend on the ventilation modes that eventually affect drip water. The multiple thermal mechanisms are winter ventilation, heat conduction in summer and water flow-induced convection derived from subsurface water percolation into the cave due to fast preferential flow during heavy rain events. Drip water response to extreme temperature anomalies is shown to be sensitive to outside climate.  相似文献   

19.
Ground water temperatures in the fractured volcanic aquifer near Yucca Mountain, Nevada, have previously been shown to have significant spatial variability with regions of elevated temperatures coinciding roughly with near-vertical north-south trending faults. Using insights gained from one-dimensional models, previous investigators have suggested upwelling along faults from an underlying aquifer as a likely explanation for this ground water temperature pattern. Using a three-dimensional coupled flow and heat-transport model, we show that the thermal high coinciding with the Paintbrush fault zone can be explained without significant upwelling from the underlying aquifer. Instead, the thermal anomaly is consistent with thermal conduction enhanced slightly by vertical ground water movement within the volcanic aquifer sequence. If more than approximately 400 m3/day of water enters the volcanic aquifer from below along a 10 km fault zone, the calculated temperatures at the water table are significantly greater than the measured temperatures. These results illustrate the potential limitations in using one-dimensional models to interpret ground water temperature data, and underscore the value in combining temperature data with fully coupled three-dimensional simulations.  相似文献   

20.
Classification of Thermal Patterns at Karst Springs and Cave Streams   总被引:1,自引:0,他引:1  
Thermal patterns of karst springs and cave streams provide potentially useful information concerning aquifer geometry and recharge. Temperature monitoring at 25 springs and cave streams in southeastern Minnesota has shown four distinct thermal patterns. These patterns can be divided into two types: those produced by flow paths with ineffective heat exchange, such as conduits, and those produced by flow paths with effective heat exchange, such as small fractures and pore space. Thermally ineffective patterns result when water flows through the aquifer before it can equilibrate to the rock temperature. Thermally ineffective patterns can be either event‐scale, as produced by rainfall or snowmelt events, or seasonal scale, as produced by input from a perennial surface stream. Thermally effective patterns result when water equilibrates to rock temperature, and the patterns displayed depend on whether the aquifer temperature is changing over time. Shallow aquifers with seasonally varying temperatures display a phase‐shifted seasonal signal, whereas deeper aquifers with constant temperatures display a stable temperature pattern. An individual aquifer may display more than one of these patterns. Since karst aquifers typically contain both thermally effective and ineffective routes, we argue that the thermal response is strongly influenced by recharge mode.  相似文献   