首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Electrical resistivity methods are applied extensively for shallow sub-surface objectives but it has constraints in distinguishing the chemical characteristics of the medium. However, this complexity can be resolved by integrated investigations where geophysical anomaly would be validated with hydro-geochemical data. The present study highlights the notable importance of integrated geophysical and hydrogeological investigations in demarcating sub-surface pollution due to saline water intrusion and industrial effluents at Cuddalore coast in India. Geophysical scanning encompassing a total of 35 vertical electrical sounding (VES) were validated with drilling lithologs, water level and water quality parameters from a network of 125 observation wells at a test site of 17 km2. To understand the spatial variation of sub-surface contamination, two profiles of apparent resistivity sections were generated covering VES points parallel to the coast. Results revealed that, the low order of resistivity range 3 to 10 Ω-m (up to 30–40 m depth) and total dissolved solids range 2000 to 10,000 mg/l of groundwater reflects sub-surface contamination but cannot distinguish kind of salinity which is further verified by chemical analysis of Ca2+ (1200–2041 mg/l), SO4 2? (3000–9480 mg/l) which confirms the gypsum pollution and Na+ (750–1000 mg/l), Cl? (1000–2000 mg/l) designate the marine water contamination. Further, static groundwater head measurements demarcate the study area into above mean sea level (MSL) and below MSL zones. This study has provided a rapid and comprehensive picture about spatial variations of groundwater contamination which can help in planning, protection and safe management of coastal aquifers in India and worldwide.  相似文献   

2.
The use of wastewater for irrigation in sandy soil increases the pollution risk of the soil and may infiltrate to the shallow groundwater aquifer. In such environment, some important parameters need to be obtained for monitoring the wastewater in the unsaturated zone over the aquifer. These parameters include clay content, heterogeneities of the upper soils, depth to the aquifer and the variations of groundwater quality. In the present work, the efficiency of DC resistivity method in forms of 1-D and 2-D measurements was studied for wastewater monitoring in the Gabal el Asfar farm, northeast of Cairo, Egypt. Forty-one Schlumberger soundings (VES) were performed then followed by three pole-dipole 2-D profiles along some considered regions within the area. The resistivity measurements were integrated with the boreholes, hydrogeological and hydrochemical (surface and groundwater samples) information to draw a clear picture for the subsurface conditions. The obtained results were presented as cross sections and 3-D visualization to trace the clay intercalations within the unsaturated zone. In addition, a vulnerability map was created using the obtained results from 1-D Schlumberger survey and confirmed with the 2-D resistivity profiling. The obtained results have shown that the 2-D resistivity imaging technique is a powerful tool for mapping the small-scale variability within the unsaturated zone and the wastewater infiltration. However, limitations of resistivity techniques were observed in the area with limited resistivity contrast such as thin clay layers with brackish water background. Under that condition, the measured pattern of resistivity distributions depends on the applied electrode array, electrode spacing and using the available geological information during the inversion process.  相似文献   

3.
Geoelectric and hydrochemical approaches are employed to delineate the ground-water potential zones in District Okara, a part of Bari Doab, Punjab, Pakistan. Sixty-seven VES surveys are conducted with the Electrical Resistivity Meter. The resultant resistivity verses depth model for each site is estimated using computer-based software IX1D. Aquifer thickness maps and interpreted resistivity maps were generated from interpreted VES results. Dar-Zarrouk parameters, transverse resistance (TR), longitudinal conductance (SL) and anisotropy (λ) were also calculated from resistivity data to delineate the potential zones of aquifer. 70% of SL value is ≤3S, 30% of SL value is > 3S. According to SL and TR values, the whole area is divided into three potential zones, high, medium and low potential zones. The spatial distribution maps show that north, south and central parts of study area are marked as good potential aquifer zones. Longitudinal conductance values are further utilized to determine aquifer protective capacity of area. The whole area is characterized by moderate to good and up to some extent very good aquifer protective area on the basis of SL values. The groundwater samples from sixty-seven installed tube wells are collected for hydro-chemical analysis. The electrical conductivity values are determined. Correlation is then developed between the EC (μS/cm) of groundwater samples vs. interpreted aquifer resistivity showing R2 value 0.90.  相似文献   

4.
A geoelectrical resistivity survey using vertical electrical sounding (VES) was conducted at Chaj Doab (land between rivers Jhelum and Chenab, Pakistan) and Rachna Doab (land between rivers Chenab and Ravi, Pakistan), with the objective of investigating groundwater conditions. A total of 90 sites were selected with 43 sites in Chaj and 47 sites in Rachna Doabs. The resistivity meter (ABEM Terrameter SAS 4000, Sweden) was used to collect the VES data by employing a Schlumberger electrode configuration, with half current electrode spacings (AB/2) ranging from 2 to 180 m and the potential electrode (MN) from 1 to 40 m. The field data were interpreted using the Interpex IX1D computer software and the resistivity versus depth models for each location was estimated. The outputs of subsurface layers with resistivities and thickness presented in contour maps and 3-D views by using SURFER software were created. A total of 102 groundwater samples from nearby hydrowells at different depths were collected to develop a correlation between the aquifer resistivity of VES and the electrical conductivity (EC) of the groundwater and to confirm the resulted geophysical resistivity models. From the correlation developed, it was observed that the groundwater salinity in the aquifer may be considered low and so safe for irrigation if resistivity >45 Ω m, and marginally fit for irrigation having resistivity between 25 and 45 Ω m. The study area has resistivities from 3.9 to 2,222 Ω m at the top of the unsaturated layer, between 1.21 and 171 Ω m, in the shallow aquifers, and 0.14–152 Ω m in the deep aquifers of the study area. The results indicate that the quality of groundwater is better near the rivers and in the shallow layers compared to the deep layers.  相似文献   

5.
The hydrochemical characteristics and quality of groundwater in Lokoja basement area have been evaluated based on different indices for assessing groundwater for drinking and irrigation purposes. Twenty groundwater samples were collected and analyzed for physicochemical parameters, major ions and heavy metals. The results revealed that the groundwater is slightly alkaline, with little variations in chemical composition. For example, electrical conductivity (EC) ranges from 242μS/cm to 1835μS/cm. The abundance of the major ions is in the order of Ca2+ >Na+>Mg2+>K+> Fe2+/3+ = HCO3 >Cl? >NO3 >SO4 >PO4. Based on the hydrochemical data, four hydrochemical facies were identified namely, Ca-Mg-HCO3, Na-K-HCO3, Na-K-Cl-SO4 and Ca-Mg-Cl-SO4 and these facies depict groundwater recharge zone, transition flow zone, deep flow zone and mixed water zone respectively. Groundwater from the area is unsuitable for drinking and domestic purposes as some of the ions and heavy metals of health concerns are well above the stipulated guideline values. Irrigation water quality indicators (salinity, Na % and Mg %), reveal that the groundwater is unsuitable for irrigation purposes. Interpreted statistical analysis reveals that the groundwater chemical compositions are controlled predominantly by weathering of litho units of the basement rocks and by drainage from domestic wastes.  相似文献   

6.
In the salinity affected lower Atrai floodplain aquifer in the NW Bangladesh, geoelectric resistivity survey and hydrochemical analysis are carried out with an aim to identify fresh and saline groundwater zones; investigate the status of salinity; evaluate hydrochemical processes involved and suggest management approaches for irrigation. Here a two-fold aquifer system, inter-layered by silt, clay and silty-clay aquitard and aquiclude is classified as: upper aquifer — spatially affected by salinity of varying degrees; and lower aquifer — generally characterized by high salinity. The aquifer with resistivity values greater than 69 Ωm is safe for irrigation use. Concentrations of major ions vary as: Ca2+>Na+>Mg2+>K+ and HCO3>Cl>NO3>SO4 2?. Groundwater is dominated by Na-Ca to Ca-Na, HCO3-Cl-SO4, Cl-SO4-HCO3 and Cl-SO4 2? facies where Ca2+, Mg2+, SO4 2?, HCO3 ?, Cl? and NO3 2? ion concentrations are statistically dominant and water is of Ca-Mg, HCO3-SO4-Cl and NO3 types. Geochemically, groundwater is hard and saline to fresh water type. Salinity increases with depth, but spatially towards the southern part. Groundwater quality is a product of water-rock interaction, direct mixing and marine spraying, or fall-out of airborne marine salts, where silicate weathering is the primary source of bivalent cations. Sediment provenance of alkaline earth silicates and higher concentrations of alkalis are derived from sources other than precipitation. In general partially or fully salinity affected upper and lower aquifers in the area except in its eastern part are not suitable for tubewell irrigation. As groundwater demand for irrigation is increasing, the saline water has progressively invaded relatively fresher parts of the aquifer by upconning. So, special salinity control management approaches can be adopted through engineering techniques such as groundwater abstraction optimization, as also through scientific behavioral approaches like groundwater demand management, salt tolerant crops production. In this context, surface water conservation and rain water harvesting for domestic and irrigational uses are recommended in the salinity affected area.  相似文献   

7.
The Panama coastal aquifer system is an important water resource in the southeast coast of Sri Lanka that provides adequate supplies of water for agriculture and domestic uses. One of the biggest threats to these fragile aquifers is the sea water intrusion. In this study, recharging mechanism and geochemical evaluation of groundwater in the coastal sandy aquifer of Panama were evaluated using chemical and stable isotope techniques. Thirty groundwater samples were collected and analyzed for their major ion concentrations and stable isotope ratios of oxygen (18O/16O) and hydrogen (D/H). All studied samples showed a ranking of major anions in the order Cl> HCO 3 > SO 4 2?  > N-NO3 ? while cations showed a decreasing order of abundance with Na> Ca2+ > Mg2+ > K+. Dominant groundwater hydrogeochemical types were Na–Cl and mixed Ca–Mg–Cl. Results of saturation index calculations indicate that the investigated groundwater body was mostly saturated with respect to calcite, dolomite and gypsum. In addition, stable isotope and geochemical data suggest that fresh groundwater in the aquifer is recharged mainly by local precipitation with slight modification from evaporation and saline water intrusions. Isotope data suggest that mixing of salt water with freshwater occurs in aquifers which are located towards the lagoon. Since the communities in the study area depend entirely on groundwater, an understanding of the hydrogeochemical characteristics of the aquifer system is extremely important for the better water resource management in the region.  相似文献   

8.
El Shalal-Kema area is located east of Aswan town and Nile River. The Quaternary sediments (unconsolidated material of sands, gravels, and clays intercalation) represent the main aquifer in the studied area. Its water is under unconfined condition, and the water table is shallow (vary from 7.5 to 16.3 m). The concerned aquifer is recharged mainly from Aswan Dam Lake, from the excess irrigation water and from septic tanks, where the area is not served by sewage system. The direction of the groundwater movement is generally from south to north. The transmissivity values of the Quaternary aquifer (from three pumping tests) are relatively high (vary from 1,996 to 3,029 m2/day). The exploitation of groundwater is carried out where there is continuous withdrawal for industrial and domestic uses with a total average quantity of groundwater of 71,304 m3 per day (25.67 million m3 per year). The hydrochemical characteristics of the Quaternary aquifer is studied based on the chemical analysis of 29 groundwater and four surface water samples collected from different sites. The chemical composition of the groundwater is dominated by calcium Ca2+ from the cations and bicarbonate (HCO 3 ? ) from the anions, and the order of cation abundance is Ca2+ > Na+ > Mg2+ > K+ and HCO 3 ? > SO 4 2? > Cl? among the anions. The groundwater types are normal chloride water, normal sulfate water, and normal carbonate water. The hypothetical salt combination revealed the presence of different salts arranged in terms of their predominant as Ca(HCO3)2, Mg(HCO3)2, NaCl, Na2SO4, MgSO4, KCL, NaHCO3, MgCl2, CaSO4, and K2SO4. The analytical measurements to the NO2 and NH3 reveal that their values decrease in summer and increase in winter due to the stoppage of pumping which leads to the increase of the wastewater quantities that reach the groundwater. The chemical and microbiological analyses show that the aquifer in this area is contaminated with fecal and disease-causing bacteria. The main cause of this contamination is the outflow from the septic tanks; therefore, the construction of sewage network is a vital solution. Chlorination is important to disinfect the groundwater at the tanks before its distribution to the houses.  相似文献   

9.
10.
Groundwater of the unconfined aquifer (1,100 sq. km) of a two-tier coastal aquifer located in the Amol–Ghaemshahr plain, Mazandaran Province, Northern Iran, is classified into fresh and brackish water types. Fresh groundwater (FGW) samples (n = 36) are characterized by Ca2+ > Na> Mg2+ > K+ and HCO3 ? > Cl? > SO4 2? > NO3 ?. Spearman’s rank correlation coefficient matrices, factor analysis data, values of the C-ratio (av. = 0.89) and CAI and values of the molar ratios of Ca2+/HCO3 ?, Ca2+/SO4 2?, Mg2+/HCO3 ? and Mg2+/SO4 2? indicate that the ionic load in the FGW is derived essentially from carbonic acid-aided weathering of carbonates and aluminosilicates, saline/sea water trapped in the aquifer sediments (now admixed with the groundwater) and ion exchange reactions. Values of the CAI and Na+/Cl? molar ratio suggest that the part of the Ca2+ (±Mg2+) content in 23 FGW samples is derived from clay minerals of the aquifer matrix, and part of the Na+ content in 20, 12, and 3 FGW samples is derived, respectively, from alkali feldspar weathering, clay minerals of the aquifer matrix and rain water and/or halite. Brackish groundwater (BGW) samples (n = 4) contain Cl? as the dominant anion and their average total ionic concentration (38.65 meq/L) is 1.79 times higher than that of the FGW samples (21.50 meq/L). BGW pockets were generated by non-conservative mixing of FGW with the upconed saline water from the underlying saline groundwater zone of the semi-confined aquifer along bore wells involved in excessive extraction of groundwater from the unconfined aquifer. Groundwater belongs essentially to “high salinity, low sodium” irrigation water class.  相似文献   

11.
A study was conducted to understand the hydrogeological processes dominating in the North 24 Parganas and South 24 Parganas based on representative 39 groundwater samples collected from selected area. The abundance of major ions was in the order of Ca2+ > Na+ > Mg2+ > K+ > Fe2+ for cations and HCO3 ? > PO4 3? > Cl? > SO4 2? > NO3 ? for anions. Piper trilinear diagram was plotted to understand the hydrochemical facies. Most of the samples are of Ca-HCO3 type. Based on conventional graphical plots for (Ca + Mg) vs. (SO4 + HCO3) and (Na + K) vs. Cl, it is interpreted that silicate weathering and ion exchange are the dominant processes within the study area. Previous studies have reported quartz, feldspar, illite, and chlorite clay minerals as the major mineral components obtained by the XRD analysis of sediments. Mineralogical investigations by SEM and EDX of aquifer materials have shown the occurrence of arsenic as coating on mineral grains in the silty clay as well as in the sandy layers. Excessive withdrawal of groundwater for irrigation and drinking purposes is responsible for fluctuation of the water table in the West Bengal. Aeration beneath the ground surface caused by fluctuation of the water table may lead to the formation of carbonic acid. Carbonic acid is responsible for the weathering of silicate minerals, and due to the formation of clay as a product of weathering, ion exchange also dominates in the area. These hydrogeological processes may be responsible for the release of arsenic into the groundwater of the study area, which is a part of North 24 Parganas and South 24 Parganas.  相似文献   

12.
This paper gives an account of the implementation of hydrochemical and isotopic techniques to identify and explain the processes that govern solute exchange in two groundwater-dependent shallow lakes in the Southeastern Pampa Plain of Argentina. Water samples (lakes, streams, spring water and groundwater) for hydrochemical and stable isotopic determination were collected and the main physical–chemical parameters were measured. The combination of stable isotope data with hydrogeochemical techniques was used for the identification of sources and preferential recharge areas to these aquatic ecosystems which allowed the explanation of the lake water origin. The hydrochemical processes which explain Los Padres Lake water chemistry are evaporation from groundwater, CO2 input, calcite dissolution, Na+ release by Ca2+ and Mg2+ exchange, and sulfate reduction. The model that best aligns with La Brava Lake hydrochemical constraints includes: mixing, CO2 and calcite dissolution, cationic exchange with Na+ release and Mg2+ adsorption, and to a lesser extent, Ca/Na exchange. This model suggests that the fractured aquifer contribution to this water body is greater than 50 %. An isotopic-specific fingerprint for each lake was identified, finding a higher evaporation rate for La Brava Lake compared to Los Padres Lake. Isotopic data demonstrate the importance of these shallow lakes as recharge areas to the regional aquifer, becoming areas of high groundwater vulnerability. The Tandilia Range System, considered in many hydrogeological studies as the impermeable bedrock of the Pampean aquifer, acts as a fissured aquifer in this area, contributing to low salinity waters and with a fingerprint similar to groundwater isotopic composition.  相似文献   

13.
Water resources are a key factor, particularly for the planning of the sustainable regional development of agriculture, as well as for socio-economic development in general. A hydrochemical investigation was conducted in the Friuli Venezia Giulia aquifer systems to identify groundwater evolution, recharge and extent of pollution. Temperature, pH, electric conductivity, total dissolved solids, alkalinity, total hardness, SAR, Ca2+, Na+, K+, Mg2+, Cl, SO4 2−, NO3 , HCO3 , water quality and type, saturation indexes and the environmental stable isotope δ18O were determined in 149 sampling stations. The pattern of geochemical and oxygen stable isotope variations suggests that the sub-surface groundwater (from phreatic and shallow confined aquifers) is being recharged by modern precipitations and local river infiltrations. Four hydrogeological provinces have been recognised and mapped in the Friuli Venezia Giulia Plain having similar geochemical signatures. These provinces have different degrees of vulnerability to contamination. The deep confined groundwater samples are significantly less impacted by surface activities; and it appears that these important water resources have very low recharge rates and would, therefore, be severely impacted by overabstraction.  相似文献   

14.
Calcite (CaCO3), dolomite [CaMg(CO3)2], silicate dissolution, ion-exchange and reverse ion-exchange reactions are the predominant processes influencing groundwater quality in the Savelugu?CNanton District. The main objective of this study is to characterize groundwater and delineate water?Crock interactions responsible for the chemical evolution of groundwater in the District. Eighty-one (81) boreholes were sampled for quality assessment. Results showed that, the pH of the boreholes are slightly acidic to basic ranging from 6.1?C8.3?pH units. Conductivity values are low to high ranging from 147?C23,200???S/cm with, 23.5?% of groundwater within the study area being either brackish (1,500?C5,000???S/cm) or saline (>5,000???S/cm) and therefore, unsuitable for potable purposes. TDS values in groundwater varied widely, ranging from 62?C11,900?mg/L. 61.7?% of groundwater within the study area are fresh (TDS?<?500?mg/L). The chemical constituents generally, have low concentrations and are within the WHO (Guidelines for drinking water quality. Revision of the 1993 Guidelines. Final Task Group Meeting. Geneva, 2004) Guideline values. The relative abundance of cations and anions in the groundwater are in the order: Ca2+?>?Na+?>?Mg2+?>?K+ and HCO3 ??>?Cl??>?SO4 2??>?NO3 ? respectively. Multivariate statistical analysis showed expected process-based relationship derived mainly from the geochemical and biochemical processes within the aquifer. Hydrochemical facies using piper plot of major ions showed one major hydrochemical water type. The Ca?CMg?CHCO3 water type. Due to the high cost of drilling of boreholes coupled with the high percentage (×1?%) of people without access to potable water in the Northern Region, it is recommended that the Government of Ghana and other stakeholders within the Water Sector take immediate measures to reduce (to recommended limits for potable uses) the levels of dissolved solids either by installing Reverse Osmosis equipments on such boreholes or employ other relatively known cheaper methods to reduce the dissolved solids to recommended limits. High yielding boreholes with hydrochemical parameters within WHO guideline limits in the Savelugu?CNanton District could also be mechanized to serve a wider area.  相似文献   

15.
Groundwater samples collected from the East Bokaro coalfield of Jharkhand state, India during the dry and rainy seasons of the year 2012. Samples were analyzed for the assessment of groundwater quality in the study area. The results of the chemical analysis indicate that the pH values were found alkaline in nature during both the season. The major cations in groundwater was in the order of Na+>Ca2+>Mg2+>K+ during the dry season while Ca2+>Na+>Mg2+>K+ during the rainy season. The abundance of the major anions was of HCO3->SO42->Cl->NO3->F- did not change on the seasonal basis. The average NO3-concentration was exceeded the desirable limit for drinking water as per Indian standard in the rainy season. Silicate weathering was inferred to be a dominant process, controlling the groundwater chemistry in both seasons, with lesser contributions by carbonate weathering and ion exchange. Leaching of salts from the unsaturated zone also has a major impact on groundwater quality during the rainy season. The water quality data indicate that groundwater is generally suitable for irrigation. However, higher salinity and residual sodium carbonate values at some sites may limit groundwater use and therefore an adequate drainage and water management plan for the study area is required.  相似文献   

16.
The assessment of hydrogeochemical processes that govern the water quality of inland freshwater aquifers in coastal environment, especially in Indian sub-continent, is occasionally attempted. To bridge the gap, a detail hydrochemical evaluation of groundwater occurring in coastal alluvium is attempted. Single set of high-density water sampling is done from a limited area to gain an in-depth knowledge of the processes that govern the water chemistry of the sandy aquifers. The water is of weak alkaline nature and less mineralized, EC being < 1,000 μS/cm in many samples. Major ion composition indicates that water is contaminated with excess concentration of nitrates. Ionic abundance is in the order of Cl? > Na > Ca2+ > HCO3 ? > SO4 2? > Mg2+  > NO3 ?. Na+ and Cl? are almost in similar proportions implying the influence of coastal climate on water quality. The water shows modest variation in their ionic assemblage among different sample points as evident from Schoeller scheme. Groundwater can be classified into three distinct facies viz. Cl?–Ca2+–Mg2+, Na+–Cl? and Ca2+–Mg2+–HCO3 ? types. The ionic assemblages, their indices, ratios and cross-plots substantiate that multiple processes were involved in the evolution of the water chemistry. Among them, silicate weathering, halite dissolution, ion exchange and base exchange played prominent role in the ion enrichment of groundwater. The aquatic chemistry is further influenced and modified by marine environment, evapotranspiration and anthropogenic inputs which is authenticated by good correlation (r 2 = 1) among the Na+–Cl?, EC–Mg2+, Na+ and Cl?. Gibbs plots established that evaporation is more responsible for contribution of minerals to the groundwater than aquifer material. Nitrate contamination can be attributed for poor sewerage disposal mechanism which is aggravated by fertilizer inputs, irrigation practices and agriculture activity. A contrasting correlation (r 2 ≥90 to <0.40) among select pairs of ions reassures dissimilar source of those ions, involvement of multiple processes and limited interaction of formation water with aquifer material.  相似文献   

17.
Continual expansion of population density, urbanization, agriculture, and industry in most parts of the world has increased the generation of pollution, which contributes to the deterioration of surface water quality. This causes the dependence on groundwater sources for their daily needs to accumulate day by day, which raises concerns about their quality and hydrogeochemistry. This study was carried out to increase understanding of the geological setup and assess the groundwater hydrogeochemical characteristics of the multilayered aquifers in Lower Kelantan Basin. Based on lithological data correlation of exploration wells, the study area can be divided into three main aquifers: shallow, intermediate and deep aquifers. From these three aquifers, 101 groundwater samples were collected and analyzed for various parameters. The results showed that pH values in the shallow, intermediate and deep aquifers were generally acidic to slightly alkaline. The sequences of major cations and anions were Na+ > Ca2+ > Mg2+ > K+ and HCO3? > Cl? > SO42? > CO32?, respectively. In the intermediate aquifer, the influence of ancient seawater was the primary factor that contributed to the elevated values of electrical conductivity (EC), Cl? and total dissolved solids (TDS). The main facies in the shallow aquifer were Ca–HCO3 and Na–HCO3 water types. The water types were dominated by Na–Cl and Na–HCO3 in the intermediate aquifer and by Na–HCO3 in the deep aquifer. The Gibbs diagram reveals that the majority of groundwater samples belonged to the deep aquifer and fell in the rock dominance zone. Shallow aquifer samples mostly fell in the rainfall zone, suggesting that this aquifer is affected by anthropogenic activities. In contrast, the results suggest that the deep aquifer is heavily influenced by natural processes.  相似文献   

18.
The phreatic aquifer beneath the Pampean plain, in eastern central Argentina, constitutes a relevant source of water supply in the area. The objective of this work was to assess the significance of the cation exchange processes in the hydrochemical evolution of this aquifer, based on a study case located in the middle and upper basin of the El Pescado creek. Results indicate that Ca2+/Na+ exchange is the main process determining the evolution of groundwater from the recharge areas (Ca–HCO3) towards the local discharge areas (Na–HCO3), as well as representing a source of Na+ contribution to the water in the aquifer. This hydrochemical characteristic is central to the identification of local discharge areas within a plain environment which extends regionally. The ion exchange capacity of these discharge areas has environmental importance, due to its influence on groundwater quality and potential groundwater uses. These results may be applied to any aquifer sharing similar hydrogeological characteristics.  相似文献   

19.
The vertical electrical sounding (VES) survey was carried out by using Schlumberger array in (12) points distributed along two profiles, except VES 6 was not located within any profile. The 2D imaging survey was carried out using Wenner array in four stations. The VES results revealed the presence of two groundwater aquifers. The first is Euphrates aquifer and the second is Dammam aquifer. While the results of 2D imaging survey distinguished two secondary aquifers in addition to previous aquifers located within Dammam formation. Also, 2D imaging gave a more accurate picture for the distribution of electrical horizons especially for the depths which ranges between 2.5 and 73 m. While the VES gives information for larger depths than that of 2D, which ranges between the earth’s surface and a depth 140 m. The geo-electrical sections of VES showed electrical horizons (layers) with sharp boundaries. But the 2D inverse models revealed the lateral and vertical variations of the resistivity within each horizon especially for shallow depths due to large volume of data available in 2D measurement. These variations were not shown in the geo-electrical sections of VES points. Comparison of VES and 2D imaging techniques revealed that the 2D imaging was the best for determined the shallow aquifers as observed from this study. It can be concluded that 2D resistivity imaging and VES can provide very useful guide for borehole drilling particularly where there is no existing well.  相似文献   

20.
Integrated geoelectrical resistivity, hydrochemical and soil property analysis methods were used to study the groundwater characteristics of sandy soils within a shallow aquifer in the agriculture area, Machang. A pilot test investigation was done prior to the main investigation. The area was divided into two sites. Test-Site 1 is non-fertilized; Test-Site 2 is the former regularly fertilized site. From the surface to depths of 75 cm, a lower average resistivity was obtained in Test-Site 2 (around 0.37 less than in Test-Site 1). The presence of nitrate and chloride contents in pore water reduced the resistivity values despite the low moisture content. The pH values for the whole area range from 4.11 to 6.88, indicating that the groundwater is moderately to slightly acidic. In the southern region, concentration of nitrate is considered to be high (>20 mg/l), while it is nearly zero in the northern region. In the south, the soil properties are similar. However, the geoelectrical model shows lower resistivity values (around 18 Ω m) at the sites with relatively high nitrate concentration in the groundwater (>20 mg/l). Conversely, the sites with low nitrate concentration reveal the resistivity values to be higher (>35 Ω m). Basement and groundwater potential maps are generated from the interpolation of an interpreted resistivity model. The areas that possibly have nitrate-contaminated groundwater have been mapped along with groundwater flow patterns. The northern part of the area has an east to west groundwater flow pattern, making it impossible for contaminated water from the southern region to enter, despite the northern area having a lower elevation.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号