This paper investigates the effects of supplemental viscous damping on the seismic response of one‐storey, asymmetric‐plan systems responding in the inelastic range of behaviour. It was found that addition of the supplemental damping reduces not only deformation demand but also ductility and hysteretic energy dissipation demands on lateral load resisting elements during earthquake loading. However, the level of reduction strongly depends on the plan‐wise distribution of supplemental damping. Nearly optimal reduction in demands on the outermost flexible‐side element, an element generally considered to be the most critical element, was realized when damping was distributed unevenly in the system plan such that the damping eccentricity was equal in magnitude but opposite in algebraic sign to the structural eccentricity of the system. These results are similar to those noted previously for linear elastic systems, indicating that supplemental damping is also effective for systems expected to respond in the inelastic range. Copyright © 2001 John Wiley & Sons, Ltd.  相似文献   

2.
Supplemental damping could mitigate the earthquake‐induced damage in buildings with asymmetric plan, known to be more vulnerable to damage than comparable symmetric‐plan buildings. This investigation aims to improve the understanding of how and why planwise distribution of fluid viscous dampers (FVDs) influences the response of linearly elastic, one‐storey, asymmetric‐plan systems. Starting with vibration mode shapes, we predict this influence on the modal damping ratios, and in turn on the individual modal responses and the total response. These predictions are confirmed by the computed responses, which demonstrated that the reduction in earthquake response of the system achieved by supplemental damping is strongly influenced by its planwise distribution, which is characterized by four parameters. Identified are asymmetric distributions of supplemental damping that are more effective in reducing the response compared to symmetric distribution. The percentage reduction achieved by a judiciously selected asymmetric distribution can be twice or even larger compared to symmetric distribution. Copyright © 2001 John Wiley & Sons, Ltd.  相似文献   

3.
This study investigated the effects of neglecting off‐diagonal terms of the transformed damping matrix on the seismic response of non‐proportionally damped asymmetric‐plan systems with the specific aim of identifying the range of system parameters for which this simplification can be used without introducing significant errors in the response. For this purpose, a procedure is presented in which modal damping ratios computed by neglecting off‐diagonal terms of the transformed damping matrix are used in the traditional modal analysis. The effects of the simplification are evaluated first by comparing the aforementioned modal damping ratios with the apparent damping ratios obtained from the complex‐valued eigenanalysis. The variation of a parameter that was defined by Warburton and Soni as an indicator of the errors introduced by the simplification is examined next. Finally, edge deformations obtained from the simplified procedure are compared with those obtained from the direct integration of the equations of motion. It is found that the simplified procedure may be used without introducing significant errors in response for most practical values of the system parameters. Furthermore, estimates of the edge deformations, in general, tend to be on the conservative side. Copyright © 2001 John Wiley & Sons, Ltd.  相似文献   

4.
Coupling between lateral and torsional motions may lead to much larger edge deformations in asymmetric-plan systems compared to systems with a symmetric plan. Supplemental viscous damping has been found to be effective in reducing deformations in the symmetric-plan system. This investigation examined how supplemental damping affects the edge deformations in asymmetric-plan systems. First, the parameters that characterize supplemental viscous damping and its plan-wise distribution were identified, and then the effects of these parameters on edge deformations were investigated. It was found that supplemental damping reduces edge deformations and that reductions by a factor of up three are feasible with proper selection of system parameters. Furthermore, viscous damping may be used to reduce edge deformations in asymmetric-plan systems to levels equal to or smaller than those in the corresponding symmetric-plan system. © 1998 John Wiley & Sons, Ltd.  相似文献   

5.
This article describes a design procedure for elastic buildings equipped with linear and nonlinear energy dissipating devices. The objective is to achieve a design that responds to a target building performance following a simple and robust step-by-step algorithm. The proposed procedure identifies first the modal significance of key design performance indicators and controls the modal properties by solving a singular two-parameter eigenvalue problem. For that purpose, a new modal significance metric is proposed, and a target frequency shift and damping ratio for the complete structure are obtained from the so-called iso-performance design curves. The design algorithm employs linear-equivalent stiffness and damping properties, which are then transformed into parameters characterizing inelastic force-deformation constitutive models corresponding to physical devices. The design algorithm leads to an optimal damper distribution corresponding to the minimum global amount of supplemental equivalent damping needed to achieve a maximum modal perturbation. The design procedure is first demonstrated using a five-story building example and then a real and complex 22-story free-plan building with two towers of rhomboid-shape plan with a very singular dynamic behavior.  相似文献   

6.
A new direct performance‐based design method utilizing design tools called performance‐spectra (P‐Spectra) for low‐rise to medium‐rise frame structures incorporating supplemental damping devices is presented. P‐Spectra are graphic tools that relate the responses of nonlinear SDOF systems with supplemental dampers to various damping parameters and dynamic system properties that structural designers can control. These tools integrate multiple response quantities that are important to the performance of a structure into a single compact graphical format to facilitate direct comparison of different potential solutions that satisfy a set of predetermined performance objectives under various levels of seismic hazard. An SDOF to MDOF transformation procedure that defines the required supplemental damping properties for the MDOF structure to achieve the response defined by the target SDOF system is also presented for hysteretic, linear viscous and viscoelastic damping devices. Using nonlinear time‐history analyses of idealized shear structures, the accuracy of the transformation procedure is verified. A seismic performance upgrade design example is presented to demonstrate the usefulness of the proposed method for achieving design performance goals using supplemental damping devices. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

7.
A method for parametric system identification of classically damped linear system in frequency domain is adopted and extended for non‐classically damped linear systems subjected up to six components of earthquake ground motions. This method is able to work in multi‐input/multi‐output (MIMO) case. The response of a two‐degree‐of‐freedom model with non‐classical damping, excited by one‐component earthquake ground motion, is simulated and used to verify the proposed system identification method in the single‐input/multi‐output case. Also, the records of a 10 storey real building during the Northridge earthquake is used to verify the proposed system identification method in the MIMO case. In this case, at first, a single‐input/multi‐output assumption is considered for the system and modal parameters are identified, then other components of earthquake ground motions are added, respectively, and the modal parameters are identified again. This procedure is repeated until all four components of earthquake ground motions which are measured at the base level of the building are included in the identification process. The results of identification of real building show that consideration of non‐classical damping and inclusion of the multi‐components effect of earthquake ground motions can improve the least‐squares match between the finite Fourier transforms of recorded and calculated acceleration responses. Copyright © 2006 John Wiley & Sons, Ltd.  相似文献   

8.
This study investigates the effectiveness of the modal analysis using two‐degree‐of‐freedom (2DOF) modal stick to deal with the seismic analysis of one‐way asymmetric elastic systems with supplemental damping. The 2DOF modal stick possessing the non‐proportional damping property enables the modal translation and rotation to not be proportional even at elastic state. The analytical results of one‐storey and three‐storey buildings obtained by the proposed method are compared with those obtained by direct integration of the equation of motion and conventional approximate method, which neglects the off‐diagonal elements in the transformed damping matrix. It is found that the proposed simplified method, compared to conventional approximate methods, can significantly improve the accuracy of the analytical results and, at the same time, without obviously increasing computational efforts. Copyright © 2006 John Wiley & Sons, Ltd.  相似文献   

9.
Lateral–torsional coupling in asymmetric‐plan buildings leads to correlated translations and rotations of the building plan, which generate uneven distributions of deformation demand among resisting planes. The deformation demand of a resisting plane depends on the relative magnitude of the plan translation and rotation and on the correlation between the two signals. Thus, small rotations highly correlated with building translation may lead to significantly different deformations of the resisting planes at the building edges. Consequently, the use of supplemental dampers is intended not only to reduce the magnitude of the plan translation and rotation, but also the correlation between these motions. For the sake of simplicity, linear viscous dampers are used in this investigation, which properly located in plan lead to a minimum response of the geometric center, thus achieving the same mean‐square value of the displacements at the building edges. Mathematically, this condition may be understood as creating zero correlation between the translations and rotation at the geometric center of the plan, which represents an uncoupling in the mean‐square sense. Results show that the optimal damper location depends on the static eccentricity and frequency ratio of the bare structure, the total amount of supplemental damping considered, and the frequency content of the excitation. Through a final 6‐story model example, the torsional balance concept is demonstrated to work on multistory buildings subjected to bidirectional ground motions. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

10.
The Rayleigh damping model, which is pervasive in nonlinear response history analysis (RHA) of buildings, is shown to develop ‘spurious’ damping forces and lead to inaccurate response results. We prove that a viscous damping matrix constructed by superposition of modal damping matrices—irrespective of the number of modes included or values assigned to modal damping ratios—completely eliminates the ‘spurious’ damping forces. This is the damping model recommended for nonlinear RHA. Replacing the stiffness‐proportional part of Rayleigh damping by the tangent stiffness matrix is shown to improve response results. However, this model is not recommended because it lacks a physical basis and has conceptual implications that are troubling: hysteresis in damping force–velocity relationship and negative damping at large displacements. Furthermore, the model conflicts with the constant‐damping model that has been the basis for fundamental concepts and accumulated experience about the inelastic response of structures. With a distributed plasticity model, the structural response is not sensitive to the damping model; even the Rayleigh damping model leads to acceptable results. This perspective on damping provides yet another reason to employ the superior distributed plasticity models in nonlinear RHA. OpenSees software has been extended to include a damping matrix defined as the superposition of modal damping matrices. Although this model leads to a full populated damping matrix, the additional computational demands are demonstrated to be minimal. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

11.
研究了应用主动锚索控制装置控制相邻建筑地震响应的有效性。首先,建立了主动锚索-相邻建筑系统的运动方程;然后应用广义振型分析方法,寻求了主动锚索联结的相邻建筑的力学特性,特别是振型阻尼比;最后,在频率域内应用广义振型分析与虚拟激励相结合的方法,建立了主动锚索控制装置联结相邻建筑的随机地震响应的分析方法。应用本文建立的公式,我们编制了计算机程序,进行了广泛的参数研究,以评价控制装置的有效性,并确定最优传感器类型及控制装置参数。研究表明,如果应用速度传感器,并能适当地选择主动锚索控制器的参数,则可以显著地提高系统的振型阻尼比,减小两个结构的地震响应。  相似文献   

12.
钢结构与混凝土结构阻尼比不同,混凝土房屋与其顶上钢塔组成了非比例阻尼结构系统。本文用非经典振型分解法求解该类结构系统的线弹性地震响应,发现只用前几阶振型响应迭加的结果即可逼近直接积分法的精确度。  相似文献   

13.
This paper presents an efficient procedure to determine the natural frequencies, modal damping ratios and mode shapes for torsionally coupled shear buildings using earthquake response records. It is shown that the responses recorded at the top and first floor levels are sufficient to identify the dominant modal properties of a multistoried torsionally coupled shear building with uniform mass and constant eccentricity even when the input excitation is not known. The procedure applies eigenrealization algorithm to generate the state‐space model of the structure using the cross‐correlations among the measured responses. The dynamic characteristics of the structure are determined from the state‐space realization matrices. Since the mode shapes are obtained only at the instrumented floor (top and first floors) levels, a new mode shape interpolation technique has been proposed to estimate the mode shape coefficients at the remaining floor levels. The application of the procedure has been demonstrated through a numerical experiment on an eight‐storied torsionally coupled shear building subjected to earthquake base excitation. The results show that the proposed parameter identification technique is capable of identifying dominant modal parameters and responses even with significant noise contamination of the response records. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

14.
This paper verifies the feasibility of the proposed system identification methods by utilizing shaking table tests of a full‐scale four‐story steel building at E‐Defense in Japan. The natural frequencies, damping ratios and modal shapes are evaluated by single‐input‐four‐output ARX models. These modal parameters are prepared to identify the mass, damping and stiffness matrices when the objective structure is modelled as a four degrees of freedom (4DOF) linear shear building in each horizontal direction. The nonlinearity in stiffness is expressed as a Bouc–Wen hysteretic system when it is modelled as a 4DOF nonlinear shear building. The identified hysteretic curves of all stories are compared to the corresponding experimental results. The simple damage detection is implemented using single‐input‐single‐output ARX models, which require only two measurements in each horizontal direction. The modal parameters are equivalent‐linearly evaluated by the recursive Least Squares Method with a forgetting factor. When the structure is damaged, its natural frequencies decrease, and the corresponding damping ratios increase. The fluctuation of the identified modal properties is the indirect information for damage detection of the structure. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

15.
Coupling adjacent buildings using discrete viscoelastic dampers for control of response to low and moderate seismic events is investigated in this paper. The complex modal superposition method is first used to determine dynamic characteristics, mainly modal damping ratio and modal frequency, of damper-linked linear adjacent buildings for practical use. Random seismic response of linear adjacent buildings linked by dampers is then determined by a combination of the complex modal superposition method and the pseudo-excitation method. This combined method can effectively and accurately determine random seismic response of non-classically damped systems in the frequency domain. Parametric studies are finally performed to identify optimal parameters of viscoelastic dampers for achieving the maximum modal damping ratio or the maximum response reduction of adjacent buildings. It is demonstrated that using discrete viscoelastic dampers of proper parameters to link adjacent buildings can reduce random seismic responses significantly. Copyright © 1999 John Wiley & Sons Ltd.  相似文献   

16.
The classical response spectrum method continues to be the most popular approach for designing base‐isolated buildings, therefore avoiding computationally expensive nonlinear time‐history analyses. In this framework, a new method for the seismic analysis and design of building structures with base isolation system (BIS) is formulated and numerically validated, which enables one to overcome the main shortcomings of existing techniques based on the response spectrum method. The main advantages are the following: first, reduced computational effort with respect to an exact complex‐valued modal analysis, which is obtained through a transformation of coordinates in two stages, both involving real‐valued eigenproblems; second, effective representation of the damping, which is pursued by consistently defining different viscous damping ratios for the modes of vibration of the coupled BIS‐superstructure dynamic system; and third, ease of use, because a convenient reinterpretation of the combination coefficients leads to a novel damping‐adjusted combination rule, in which just a single response spectrum is required for the reference value of the viscous damping ratio. The proposed approach is specifically intended for design situations where (i) the dynamic behaviour of seismic isolators can be linearised and (ii) effects of nonproportional damping, as measured by modal coupling indexes, are negligible in the BIS‐superstructure assembly. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

17.
In the current code requirements for the design of base isolation systems for buildings located at near-fault sites, the design engineer is faced with very large design displacements for the isolators. To reduce these displacements, supplementary dampers are often prescribed. These dampers reduce displacements, but at the expense of significant increases in interstorey drifts and floor accelerations in the superstructure. An elementary analysis based on a simple model of an isolated structure is used to demonstrate this dilemma. The model is linear and is based on modal analysis, but includes the modal coupling terms caused by high levels of damping in the isolation system. The equations are solved by a method that avoids complex modal analysis. Estimates of the important response quantities are obtained by the response spectrum method. It is shown that as the damping in the isolation system increases, the contribution of the modal coupling terms due to isolator damping in response to the superstructure becomes the dominant term. The isolator displacement and structural base shear may be reduced, but the floor accelerations and interstorey drift are increased. The results show that the use of supplemental dampers in seismic isolation is a misplaced effort and alternative strategies to solve the problem are suggested. Copyright © 1999 John Wiley & Sons, Ltd.  相似文献   

18.
Closed‐form solution for seismic response of adjacent buildings connected by hydraulic actuators with linear quadratic Gaussian (LQG) controllers is presented in this paper. The equations of motion of actively controlled adjacent buildings against earthquake are first established. The complex modal superposition method is then used to determine dynamic characteristics, including modal damping ratio, of actively controlled adjacent buildings. The closed‐form solution for seismic response of the system is finally derived in terms of the complex dynamic characteristics, the pseudo‐excitation method and the residue theorem. By using the closed‐form solution, extensive parametric studies can be carried out for the system of many degrees of freedom. The beneficial parameters of LQG controllers for achieving the maximum response reduction of both buildings using reasonable control forces can be identified. The effectiveness of LQG controllers for this particular application is evaluated in this study. The results show that for the adjacent buildings of different dynamic properties, if the parameters of LQG controllers are selected appropriately, the modal damping ratios of the system can be significantly increased and the seismic responses of both buildings can be considerably reduced. Copyright © 2001 John Wiley & Sons, Ltd.  相似文献   

19.
Output‐only system identification is developed here towards assessing current modal dynamic properties of buildings under seismic excitation. Earthquake‐induced structural response signals are adopted as input channels for two different Operational Modal Analysis (OMA) techniques, namely, a refined Frequency Domain Decomposition (rFDD) algorithm and an improved Data‐Driven Stochastic Subspace Identification (SSI‐DATA) procedure. Despite that short‐duration, non‐stationary, earthquake‐induced structural response signals shall not fulfil traditional OMA assumptions, these implementations are specifically formulated to operate with seismic responses and simultaneous heavy damping (in terms of identification challenge), for a consistent estimation of natural frequencies, mode shapes, and modal damping ratios. A linear ten‐storey frame structure under a set of ten selected earthquake base‐excitation instances is numerically simulated, by comparing the results from the two identification methods. According to this study, best up‐to‐date, reinterpreted OMA techniques may effectively be used to characterize the current dynamic behaviour of buildings, thus allowing for potential Structural Health Monitoring approaches in the Earthquake Engineering range.  相似文献   

20.
Simple approximate expressions are derived for estimating equivalent modal parameters of a single soft-soil layer that has a straight line distribution of shear wave velocities and is on a flexible half space which is more rigid than the overlying soil layer. It is shown that radiation damping from the flexibility of the half space can be converted approximately into an equivalent material damping and that a site of a single soft-soil layer on a flexible half space can be replaced by an equivalent single layer, with the same shear wave velocity distribution, on a rigid bedrock. The implementation for modal analyses and non-linear analyses of the equivalent site under earthquake excitation is discussed.  相似文献   