共查询到20条相似文献,搜索用时 250 毫秒
1.
Recent studies have shown that many natural systems display temporal fluctuations with long-range power-law correlations, suggesting a fractal geometry of the underlying dynamical system. Four geoelectrical time series, measured in a seismic area of Southern Italy, are investigated by means of spectral tools in order to evidence the existence of power-law correlations. Results show the scaling behaviour for all the signals recorded, pointing to the presence of fractal features expressing a long-term correlation with scaling exponents which indicate stabilizing mechanisms. Furthermore, our findings suggest an observational evidence of correlations between the variation of parameters describing the temporal fluctuations of geoelectrical signals and earthquakes that occurred in the area investigated. 相似文献
2.
In the present paper we analyse the series of extreme events in geoelectrical signals recorded at the monitoring station Tito located in a seismic area of southern Italy. Applying an objective criterion to estimate the probability of occurrence of extreme events in the time series (Cuomo et al., 1996; Cuomo et al., 1997), we found a correlation between the geoelectrical anomalies and earthquakes in the area monitored during the period of recording. 相似文献
3.
4.
5.
A hydrogeophysical model of the relationship between geoelectric and hydraulic parameters of anisotropic aquifers 总被引:1,自引:0,他引:1
An electrical resistivity method has been used to determine aquifer parameters in the Ganga-Yamuna interfluve in northern India. An existing relationship between the geoelectrical and hydraulic parameters has been modified for the case of an anisotropic aquifer. The hydrogeological framework in the upper part of the Ganga-Yamuna interfluve is evaluated by using existing relationships between hydraulic parameters and geoelectrical parameters for alluvial aquifers. On the basis of aquifer geometry, the area has been divided into two hydraulic units: the western Yamuna flood plain and the Ganga flood plain towards the east. The resistivity data collected in parts of the study area are first interpreted in terms of true resistivity and thicknesses of subsurface layers. The electrical parameters (resistivity and thicknesses) are subsequently correlated with the available pumping test data. Distinct correlations between transmissivity and modified transverse resistance are obtained for the two hydraulic units. A four-parameter model consisting of hydraulic conductivity, modified longitudinal resistivity, modified transverse resistance and hydraulic anisotropy is presented for the anisotropic aquifer underlain by conductive fine grained sediments. The model has been validated at a number of locations, where aquifer parameters are known from pumping test data. 相似文献
6.
7.
8.
The biochronology of Cenomanian-early Turonian ammonite faunas from three key stratotype areas (north-west Europe, central Tunisia and the Western Interior of North America) has been analysed and revised by utilizing the unitary association method. This review is prompted by the huge amount of biostratigraphic data published during recent decades and by a taxonomic homogenisation of the ammonite faunas from these key areas. The Cenomanian and lower Turonian of Tunisia comprise twenty-four Unitary Association zones and the middle Cenomanian-lower Turonian of the Western Interior Basin twenty-three such zones. The unitary association method means a two-fold increase in resolution of these ammonite zonations compared to the standard, empirical schemes. Central Tunisia and the Western Interior are correlated with north-west Europe by constructing a zonation including all taxa common to these areas. These correlations highlight the variable completeness and resolution of the faunal record through space and time, and reveal a significant number of diachronous taxa between the three areas. These correlations enable the designation of a new global marker for the middle/upper Cenomanian boundary, which is characterised by the disappearance of the genera Turrilites, Acanthoceras and Cunningtoniceras and by the appearance of Eucalycoceras, Pseudocalycoceras and Euomphaloceras. The only synchronous datum known is the last occurrence of Turrilites acutus, which may thus be used as a marker for the middle/upper Cenomanian boundary, provided that it does not turn out to be diachronous in the light of any new data. 相似文献
9.
Abdelkader Mhamdi Mouez Gouasmia Mohamed Gasmi Salem Bouri Hamed Ben Dhia 《Comptes Rendus Geoscience》2006,338(16):1228-1239
The Mida plain, which is part of the North Gabès region (southern Tunisia), is characterized by the deep sandy units of the ‘Continental intercalaire’ (CI) or the limestone of the Lower Senonian. A geophysical survey, by electrical sounding (ES), was undertaken in the studied region to better characterize the deep geological structure of this plain and therefore its aquifer resources potential. The analysis of the results shows that the prospected zone is characterized by the succession of several levels with contrasted resistivities, which are often affected by faults. Among these observed geoelectrical levels, the highly conductor one could host a saline aquifer. Another geoelectrical level corresponding to the resistant bedrock detected at Oudhref horst can contain better-quality water than that of the aquifer detected in the El Mida Graben. In this work, we tried to explain the origin of the salinity of this aquifer. Thus, we hypothesise about a contamination from Jebel Zemlet El Beida through a border fault and another one from the Sebkhet El Hamma. To cite this article: A. Mhamdi et al., C. R. Geoscience 338 (2006). 相似文献
10.
Application of integrated geoelectrical methods in Marand (Iran) manganese deposit exploration 总被引:1,自引:0,他引:1
This paper addresses the application of integrated geoelectrical methods including induced polarization (IP), resistivity (RS), and self-potential (SP) for exploration and evaluation of the Marand (Iran) manganese deposit. The SP method was used for reconnaissance, in which five profiles were designed and surveyed with a reference electrode that was placed in a distance of at least 800 m far from the measurement points. For the conduct of RS and IP, a new array proposed by Ramazi (2005a), named combined resistivity profiling and sounding (CRSP) was used along nine profiles that made it possible to do sounding survey and produce apparent resistivity pseudo-sections. Some anomalies were detected by means of SP surveys along the profiles and some other were located from IP and RS pseudo-sections, and there was good consistency between anomalies detected by IP and RS and SP method. To check the efficiency of CRSP and in comparison with dipole–dipole array, in the location of profile no. 6, a profile with the dipole–dipole array was designed and surveyed. Finally, by integration of the results from the geoelectrical methods, some locations were suggested for borehole drilling. After drilling in those locations, cores were studied and compared with the results obtained from the geoelectrical methods that resulted in confirmation of the geoelectrical findings. The results obtained by the CRSP array have a match better than the drilling results. 相似文献
11.
12.
Adel D. M. Kotb Mohamed A. Khaled Mostafa S. Barseem 《Arabian Journal of Geosciences》2018,11(19):596
El Alamein-El-Dabaa area lies in the western Mediterranean coastal zone of Egypt with about 50 km long. The aims of the present study are the shallow groundwater aquifer determination and calculate the electric parameters of the overburden to achieve the easiest way for detecting groundwater contamination and considered it during the planning of new development project(s). To attain this target, 44 vertical resistivity soundings using Schlumberger array of the maximum AB/2?=?1000 m in the form of four profiles were carried out. From the interpretation results, six geoelectrical layers have been established in the area, and iso-resistivity, depth to water, and isopach contour maps are presented. Four geoelectrical cross-sections (two geoelectrical cross-sections are parallel to the Mediterranean shoreline and the other two are normal to the Mediterranean shoreline) have been constructed. According to this work, the upper part of the Oolitic Limestone represents the shallow groundwater aquifer in this area and can be distinguished into two zones. The upper zone is brackish, whereas the lower one is saline. The geoelectrical succession reveals that the aquifer is free type. The depth to water ranges between 20 and 63 m; therefore, it is the choice as the best sites for groundwater exploitation. In the area under study, the depth to water and the thickness of the brackish increase towards the south side as well as the depth to the brackish water. The Dar-Zarrouk parameters clarified that there are some parts that may contaminate pathways and other parts are not. 相似文献
13.
Salinity mapping of coastal groundwater aquifers using hydrogeochemical and geophysical methods: a case study from north Kelantan,Malaysia 总被引:2,自引:0,他引:2
Integrated hydrogeochemical and geophysical methods were used to study the salinity of groundwater aquifers along the coastal
area of north Kelantan. For the hydrogeochemical investigation, analysis of major ion contents of the groundwater was conducted,
and other chemical parameters such as pH and total dissolved solids were also determined. For the geophysical study, both
geoelectrical resistivity soundings and reflection seismic surveys were conducted to determine the characteristics of the
subsurface and groundwater contained within the aquifers. The pH values range from 6.2 to 6.8, indicating that the groundwater
in the study area is slightly acidic. Low content of chloride suggests that the groundwater in the first aquifer is fresh,
with an average concentration of about 15.8 mg/l and high geoelectrical resistivity (>45 ohm m). On the other hand, the groundwater
in the second aquifer is brackish, with chloride concentration ranging from 500 mg/l to 3,600 mg/l and very low geoelectrical
resistivity (<45 ohm m) as well as high concentration of total dissolved solids (>1,000 mg/l). The groundwater in the third
aquifer is fresh, with chloride concentrations generally ranging from 2 mg/l to 210 mg/l and geoelectrical resistivity of
greater than 45 ohm m. Fresh and saltwater interface in the first aquifer is generally located directly in the area of the
coast, but, for the second aquifer, both hydrogeochemical and geoelectrical resistivity results indicate that the fresh water
and saltwater interface is located as far as 6 km from the beach. The considerable chloride ion content initially suggests
that the salinity of the groundwater in the second aquifer is probably caused by the intrusion of seawater. However, continuous
monitoring of the chloride content of the second aquifer indicated no significant changes with time, from which it can be
inferred that the salinity of the groundwater is not affected by seasonal seawater intrusion. Schoeller diagrams illustrate
that sulphate concentrations of the groundwater of the second aquifer are relatively low compared to those of the recent seawater.
Therefore, this result suggests that the brackish water in the second aquifer is probably from ancient seawater that was trapped
within the sediments for a long period of time, rather than due to direct seawater intrusion. 相似文献
14.
15.
Significance of Dar-Zarrouk parameters in the exploration of quality affected coastal aquifer systems 总被引:1,自引:0,他引:1
The interpreted Earth subsurface resistivity layer parameters of 55 vertical geoelectrical soundings are analyzed over a fan shaped area of 1,700 km2 from Pipli-Astrang-Bhramgiri, Orissa, India. In this study, Dar-Zarrouk (D-Z) parameters, namely the longitudinal conductance (S), transverse resistance (T) and longitudinal resistivity (R
s
) are analyzed and we encountered the resistivity regime of the clay layers, saline and fresh water bearing formations. The significance of these parameters in establishing an easily decipherable vision about the occurrence and distribution of fresh and saline water aquifers, while dealing with complicated situations of intermixing of the resistivity ranges of saline and fresh water aquifers has been illustrated. The results show that the Dar-Zarrouk (D-Z) parameters provide a useful and confident solution in delineating the saline and fresh water aquifers. The behavior of the D-Z parameters S, T and R
s
, and its patterns in space over large areas with respect to the occurrence of saline water and fresh water aquifer systems in the deltaic coastal aquifer system has been demonstrated. 相似文献
16.
Geoenvironmental site investigation using different techniques in a municipal solid waste disposal site in Brazil 总被引:3,自引:0,他引:3
Giulliana Mondelli Heraldo Luiz Giacheti Maria Eugênia Gimenez Boscov Vagner Roberto Elis Jorge Hamada 《Environmental Geology》2007,52(5):871-887
Different geoenvironmental site investigation techniques to assess contamination from a municipal solid waste disposal site
in Brazil are presented here. Superficial geophysical investigation (geoelectrical survey), resistivity piezocone penetration
tests (RCPTU), soil samples collected with direct-push samplers and water samples collected from monitoring wells were applied
in this study. The application of the geoelectrical method was indispensable to identify the presence and flow direction of
contamination plumes (leachate) as well as to indicate the most suitable locations for RCPTU tests and soil and water sampling.
Chemical analyses of groundwater samples contributed to a better understanding of the flow of the contaminated plume. The
piezocone presented some limitations for tropical soils, since the groundwater level is sometimes deeper than the layer which
is impenetrable to the cone, and the soil genesis and unsaturated conditions affect soil behavior. The combined interpretation
of geoelectrical measurements and soil and water samplings underpinned the interpretation of RCPTU tests. The interpretation
of all the test results indicates that the contamination plume has already overreached the landfill’s west-northwest borders.
Geoenvironmental laboratory test results suggest that contamination from the solid waste disposal site has been developing
gradually, indicating the need for continuous monitoring of the groundwater. 相似文献
17.
Aysan Gürer Tunç Bahadır Varlı Osman Metin İlkışık Ömer Feyzi Gürer 《Environmental Earth Sciences》2016,75(23):1480
Subsurface structures from two different districts of Istanbul, hosting waste and freshwater transmission lines, were imaged by geoelectrical method. The environmental impact on Ka??thane-Terkos freshwater transmission line is one of the issues. That waterline underwent a substantial landslide damage. The previous site selection of Ka??thane-Terkos line was only based on surface geological observations. Even though the pipeline was positioned away from the surface scarps of landslides, the pipes were damaged. To find out the reason, we made some vertical electrical sounding measurements using Schlumberger array in the region. We inverted the electrical sounding data using 2D inversion technique. The final geoelectrical images show main landslide failures, at about 10–30 m depth, which are overlain by debris with a resistivity value of with <6 Ω m. The geoelectrical findings reveal that a buried major failure surrounds the surface landslides behind. Consequently, the water infrastructure remains under the influence of landslide. Our second application site was the area of the Sazl?dere tunnel, which will transfer wastewater, polluting Sazl?dere dam, to the treatment plant. The geoelectrical images along Sazl?dere tunnel route show resistive (<100 Ω m) and moderately conductive (≤50 Ω m) structures along the tunnel axis, representing unaltered to highly weathered rocks, respectively. Furthermore, consecutive hidden fault zones which severely affect the construction process of the tunnel are detected and located. 相似文献
18.
19.
Integrated geoelectrical resistivity and hydrogeochemical methods for delineating and mapping heavy metal zone in aquifer system 总被引:1,自引:0,他引:1
Nur Islami Samsudin Hj Taib Ismail Yusoff Azman Abdul Ghani 《Environmental Earth Sciences》2018,77(10):383
A novel study on using geoelectrical resistivity, soil property, and hydrogeochemical analysis methods for delineating and mapping of heavy metal in aquifer system is presented in this paper. A total of 47 surveys of geoelectrical resistivity with Wenner configuration were conducted to determine the subsurface and the groundwater characteristics. The groundwater sample from 53 existing wells and 2 new wells has been analyzed to derive their water chemical content. The chemical analysis was done on the soil sample obtained from new two wells and from selected locations. The water and soil chemical analysis results from the new two wells were used as calibration in resistivity interpretation. The occurrence of heavy metal in aquifer system was expected to detect using the geoelectrical resistivity survey for the whole study area. The result of groundwater analysis shows that the groundwater sample contains a relatively low concentration of Fe (<?0.3 mg/L) elongating from the south up to the middle region. While in the middle and the northwestern, Fe concentration is relatively high (around 12 mg/L). Chemical analysis of soil sample shows that in the lower resistivity zone (<?18 Ωm), Al and Fe concentrations are comparatively high with an average of 68,000 and 40,000 mg/kg, respectively. Starting from the middle to the northwestern zone, the resistivity value appears to be low. It is definitely caused by higher Al and Fe concentration within the soil, and it is supported also by lower total anion content in the groundwater. While the resistivity value of more than 40 Ωm in aquifers is obtained in the zone which Fe concentration is relatively lower in the soil but not present in the groundwater. Correlation Fe concentration in the soil and Fe concentration in the groundwater sample shows the trend of positively linear; however, the Al concentration in soil has no correlation with Al content in groundwater. Finally, the probability of high heavy metal zone in the aquifer system is easily delineated by the distribution of geoelectrical resistivity presented in depth slice shapes which extend from the Boundary Range Composite Batholith in the north to the northwest. 相似文献
20.
Integrated geoelectrical survey for groundwater and shallow subsurface evaluation: case study at Siliyin spring, El-Fayoum, Egypt 总被引:3,自引:1,他引:2
Mohamed Metwaly Gad El-Qady Usama Massoud Abeer El-Kenawy Jun Matsushima Nasser Al-Arifi 《International Journal of Earth Sciences》2010,99(6):1427-1436
Siliyin spring is one of the many natural fresh water springs in the Western Desert of Egypt. It is located at the central
part of El-Fayoum Delta, which is a potential place for urban developments and touristic activities. Integrated geoelectrical
survey was conducted to facilitate mapping the groundwater resources and the shallow subsurface structures in the area. Twenty-eight
transient electromagnetic (TEM) soundings, three vertical electrical soundings (VES) and three electrical resistivity tomography
(ERT) profiles were carried out around the Siliyin spring location. The dense cultivation, the rugged topography and the existence
of infra structure in the area hindered acquiring more data. The TEM data were inverted jointly with the VES and ERT, and
constrained by available geological information. Based on the inversion results, a set of geoelectrical cross-sections have
been constructed. The shallow sand to sandy clay layer that forms the shallow aquifer has been completely mapped underneath
and around the spring area. Flowing of water from the Siliyin spring is interconnected with the lateral lithological changes
from clay to sand soil. Exploration of the extension of Siliyin spring zone is recommended. The interpretation emphasizes
the importance of integrating the geoelectrical survey with the available geological information to obtain useful, cheap and
fast lithological and structural subsurface information. 相似文献