首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 225 毫秒
1.
The effect of vertical excitation on shear capacity of reinforced concrete columns is important. Field evidences, analytical studies and static or hybrid simulations suggested that excessive tension or tensile strain of the column may lead to shear strength degradation, and therefore vertical excitation can be one of the causes of shear failure. This paper describes an experimental study consisting of shaking table tests on reduced‐scale bridge columns. Results of the tests indicate that tension in the columns has the potential to degrade the shear capacity, which is mainly due to the degradation of the concrete contribution to this capacity. The presented computational results and code evaluations also support this shear strength degradation. The presented dynamic tests contribute to better understanding of the effect of vertical excitation on the shear failure, which is one of the most critical brittle failure mechanisms. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

2.
This paper reports a study for the seismic performance of one large‐scaled (1/15) model of 30‐story steel‐reinforced concrete frame‐concrete core wall mixed structure. The study was implemented by both shaking table tests, in which the similarity ratio for lateral and gravitational accelerations was kept to 1:1, and numerical nonlinear dynamic analysis. The test observations presented herein include story displacement, interstory drift, natural vibration periods, and final failure mode. The numerical analysis was performed to simulate the shaking table test procedure, and the numerically obtained responses were verified by the test results. On the basis of the numerical results, the progressions of structural stiffness, base shear, and overturning moment were investigated, and the distributions of base shear and overturning moment between frame and core wall were also discussed. The test demonstrates the seismic performance of the steel‐reinforced concrete frame‐core wall mixed structure and reveals the potential overturning failure mode for high rise structures. The nonlinear analysis results indicate that the peripheral frames could take more shear forces after core wall damaged under severe earthquakes. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

3.
钢管混凝土边框高强混凝土组合剪力墙抗震性能试验研究   总被引:6,自引:1,他引:5  
钢管混凝土边框组合剪力墙是一种新型组合剪力墙。本文进行了2个1/4缩尺的高强混凝土剪力墙模型的低周反复荷载试验,模型1为普通钢筋混凝土剪力墙,模型2为钢管混凝土边框组合剪力墙。在试验研究基础上,对比分析它们的承载力、延性、刚度及其衰减过程、滞回特性、耗能能力及破坏特征,建立了组合剪力墙的承载力计算模型,计算结果与实测结果符合较好。研究表明,钢管混凝土边框高强混凝土组合剪力墙与普通剪力墙相比抗震性能显著提高。  相似文献   

4.
结构弹塑性反应可用等效线性化方法中的等效刚度和等效阻尼比进行计算。为研究钢筋混凝土剪力墙的等效刚度和等效阻尼比,通过分析剪力墙的力-位移简化四折线滞回模型,推导了其屈服点和峰值点的等效刚度、等效周期和等效阻尼比的计算公式。为验证其准确性和适用性,采用提出的峰值点等效刚度、等效阻尼比公式和FEMA 440建议的公式,分别计算了42片钢筋混凝土剪力墙试件的等效刚度和等效阻尼比,并进行了对比分析。结果表明:提出的计算公式和FEMA 440建议的公式所得到的等效周期和等效阻尼比值与试验值比较吻合,因此,所提出的计算剪力墙的等效周期和等效阻尼比的公式较为合理。  相似文献   

5.
型钢混凝土梁柱框支剪力墙结构抗震性能试验研究   总被引:3,自引:0,他引:3  
框支剪力墙结构在实际工程中经常被采用,震害表明钢筋混凝土框支剪力墙结构抗震性能较差,本文提出型钢混凝土梁柱框支剪力墙结构对此加以改进。作者进行了4个1/4缩尺模型在竖向荷载和单调及低周反复水平荷载作用下的对比试验,其中3个试件采用型钢混凝土转换梁、型钢混凝土框支柱,1个试件采用钢筋混凝土转换梁、钢筋混凝土框支柱。我们分析其承载力、刚度、变形、延性和破坏形态等。试验结果表明,型钢混凝土梁柱框支剪力墙结构承载力高、延性好、滞回曲线丰满,变形能力和耗能能力较强。  相似文献   

6.
Shaking table test results from a one‐story, two‐bay reinforced concrete frame sustaining shear and axial failures are compared with nonlinear dynamic analyses using models developed for the collapse assessment of older reinforced concrete buildings. The models provided reasonable estimates of the overall frame response and lateral strength degradation; however, the measured drifts were underestimated by the models. Selected model parameters were varied to investigate the sensitivity of the calculated response to changes in the drift at shear failure, rate of shear strength degradation, and drift at axial failure. For the selected ground motion, the drift at shear failure and rate of shear strength degradation did not have a significant impact on the calculated peak drift. By incorporating shear and axial‐load failure models, the analytical model is shown to be capable of predicting the axial‐load failure for a hypothetical frame with three nonductile columns. Improvements are needed in drift demand estimates from nonlinear dynamic analysis if such analyses are to be used in displacement‐based performance assessments. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

7.
为了研究采用灌浆套筒连接装配式剪力墙结构的抗爆性能,应用显式动力分析软件LS-DYNA建立了现浇剪力墙和装配式剪力墙的有限元模型,对不同爆炸荷载下剪力墙的破坏形态和动态响应进行了模拟分析;扩充影响参数范围,进一步研究了墙体厚度和混凝土强度等级等因素对装配式剪力墙结构抗爆性能的影响。数值分析表明:对于装配式剪力墙,由于坐浆层处存在新旧混凝土的薄弱粘结面,爆炸作用下首先发生破坏,爆炸应力波聚集于坐浆层周围的墙体内部,导致局部发生脆性破坏;现浇剪力墙刚度分布比较均匀,爆炸作用下背爆面的混凝土首先被拉裂,最终发生弯曲破坏;增加墙体厚度、提高混凝土强度等级和改变炸药爆炸位置均可改善装配式剪力墙的抗爆性能。  相似文献   

8.
为研究网格间距对网格剪力墙抗震性能的影响,对两个竖肢中心距不同的小剪跨比网格剪力墙进行了拟静力试验及有限元分析。结果表明:横肢中心距相同、竖肢中心距分别为200 mm及300 mm的网格剪力墙破坏模式不同,竖肢中心距为200 mm的网格剪力墙下部和墙底角部混凝土破坏,破坏模式为剪压破坏;竖肢中心距为300 mm的网格剪力墙沿对角线主斜裂缝错动并产生滑移,破坏模式为剪拉破坏。两个试件的极限位移角均在1/100左右,竖肢中心距为300 mm的网格剪力墙刚度和承载力略大。有限元模拟结果与试验吻合良好,验证了模拟方法的有效性。提出了适用于不同间距网格墙的等效厚度计算方法,网格剪力墙可等效为实体剪力墙计算刚度和承载力。  相似文献   

9.
An experimental investigation on the seismic behavior of a type of outrigger truss-reinforced concrete wall shear connection using multiple steel angles is presented. Six large-scale shear connection models, which involved a portion of reinforced concrete wall and a shear tab welded onto a steel endplate with three steel angles, were constructed and tested under combined actions of cyclic axial load and eccentric shear. The effects of embedment lengths of steel angles, wall boundary elements, types of anchor plates, and thicknesses of endplates were investigated. The test results indicate that properly detailed connections exhibit desirable seismic behavior and fail due to the ductile fracture of steel angles. Wall boundary elements provide beneficial confinement to the concrete surrounding steel angles and thus increase the strength and stiffness of connections. Connections using whole anchor plates are prone to suffer concrete pry-out failure while connections with thin endplates have a relatively low strength and fail due to large inelastic deformations of the endplates. The current design equations proposed by Chinese Standard 04G362 and Code GB50011 significantly underestimate the capacities of the connection models. A revised design method to account for the influence of previously mentioned test parameters was developed.  相似文献   

10.
应变率对钢筋混凝土剪力墙动态性能的影响   总被引:1,自引:0,他引:1  
张皓  李宏男 《地震学刊》2010,(3):303-308
采用有限元软件ABAQUS中的显示动力分析模块ABAQUS/Explicit,分别对钢筋混凝土剪力墙准静态和高应变率动力荷载作用下的响应进行了数值模拟;通过比较高应变率与准静态加载下的分析结果,探讨了地震作用下应变率对钢筋混凝土剪力墙动态性能的影响。研究结果表明,受应变率效应的影响,混凝土和钢筋的动态力学行为发生了变化,动力荷载作用下的钢筋混凝土剪力墙的承载能力有一定程度的提高,故在对钢筋混凝土结构进行抗震分析时,应适当考虑应变率效应。  相似文献   

11.
钢筋混凝土短肢剪力墙抗震性能试验研究   总被引:7,自引:0,他引:7  
通过6片1:2单层短肢墙试体的低周反复荷戴试验,研究了在低周反复荷载作用下钢筋混凝土短肢剪力墙的整体工作性能、破坏形态及滞回特性。结果表明:试件的最终破坏均是由连梁失效引起的,连梁是短肢剪力墙结构的薄弱环节,因此,连梁的混凝土强度不应低于墙肢的混凝土强度,以免连梁出现粘结破坏;有翼墙的短肢剪力墙试体其延性系数都达到了3.5以上.其耗能能力较无翼墙短肢墙好。  相似文献   

12.
A new type of hybrid coupled wall system, consisting of rolled steel coupling beams, reinforced concrete (RC) wall piers, and concrete‐filled tube (CFT) short columns, is introduced. In this new system, the bases of the wall piers are connected to the base beams only through CFT short columns, unlike conventional coupled walls. Yield occurs in the coupling beams and the short columns; hence, in the RC wall piers, only minimum cracking appears. A total of four subassembly specimens, designed to fail in various collapse mechanisms, were cyclically loaded under constant axial force. A benchmark specimen showed ductile behavior with large energy dissipation until fracture occurred in the coupling beam. In the specimen designed to fail in shear in its CFT, substantial axial shortening was observed, but the overall behavior was ductile. Behavior of specimens with small amounts of section steel in the wall panel fringe, or with thin wall panels, also showed ductile behavior, but the strength and energy dissipation were significantly smaller than other two specimens. An analytical model was proposed for a frame analysis program using fiber elements to simulate elastic–plastic behavior of the system. Design methods to prevent shear failure of CFT and RC panels are suggested using the analytical and test results. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

13.
为研究Tilt-up建筑体系新型再生混凝土夹心保温墙体的抗震性能,设计制作3片分别带有门洞、窗洞、不带洞口的新型再生混凝土夹心保温墙和1片普通再生混凝土剪力墙试件,进行水平低周反复荷载试验。着重考察了墙体的开裂方式、破坏形态、滞回性能、承载力以及刚度退化性能、耗能性能等。试验结果表明:不带洞口的新型再生混凝土夹心保温墙体和传统的再生混凝土墙体均具有良好的抗震性能,洞口形式对新型再生混凝土夹心保温墙体的抗震性能影响较大,提出应严格控制开洞大小和形式,并配置加强筋以防止墙肢发生剪切脆性破坏等建议。  相似文献   

14.
In recent earthquakes, a large number of reinforced concrete (RC) bridges were severely damaged due to mixed flexure-shear failure modes of the bridge piers. An integrated experimental and finite element (FE) analysis study is described in this paper to study the seismic performance of the bridge piers that failed in flexure-shear modes. In the first part, a nonlinear cyclic loading test on six RC bridge piers with circular cross sections is carried out experimentally. The damage states, ductility and energy dissipation parameters, stiffness degradation and shear strength of the piers are studied and compared with each other. The experimental results suggest that all the piers exhibit stable flexural response at displacement ductilities up to four before exhibiting brittle shear failure. The ultimate performance of the piers is dominated by shear capacity due to significant shear cracking, and in some cases, rupturing of spiral bars. In the second part, modeling approaches describing the hysteretic behavior of the piers are investigated by using ANSYS software. A set of models with different parameters is selected and evaluated through comparison with experimental results. The influences of the shear retention coefficients between concrete cracks, the Bauschinger effect in longitudinal reinforcement, the bond-slip relationship between the longitudinal reinforcement and the concrete and the concrete failure surface on the simulated hysteretic curves are discussed. Then, a modified analysis model is presented and its accuracy is verified by comparing the simulated results with experimental ones. This research uses models available in commercial FE codes and is intended for researchers and engineers interested in using ANSYS software to predict the hysteretic behavior of reinforced concrete structures.  相似文献   

15.
为了研究低层装配式钢筋混凝土水平坐浆墙体的抗震性能,对3个不同剪跨比的低层装配式钢筋混凝土水平坐浆墙体进行了低周反复荷载试验。根据试验结果,分析了剪跨比对墙体的破坏形态、承载力、变形能力、刚度退化和耗能能力的影响。结果表明:随着剪跨比的减小,墙体的破坏形态由弯曲破坏转为剪切破坏;试件SW2和试件SW3的承载力相对于试件SW1分别提高68%和110%,延性分别降低21.8%和37.5%;试件SW1的耗能能力最好,刚度退化速度最缓慢;预制钢筋混凝土墙板与现浇边缘构件协同合作,连接处无竖向裂缝,墙体整体性较好,具有良好的抗震性能,可用于我国城镇建设中的低层住宅结构。  相似文献   

16.
高轴压比下钢管混凝土边框组合剪力墙抗震性能试验研究   总被引:8,自引:1,他引:7  
钢管混凝土边框组合剪力墙是一种适用于高层及超高层建筑的新型组合剪力墙。轴压比是影响剪力墙抗震性能的一个主要因素,高层建筑底部轴压比较大。本文进行了1/4缩尺的1个普通钢筋混凝土剪力墙模型和1个钢管混凝土边框组合剪力墙模型在高轴压比下的低周反复荷载试验。在试验研究基础上,对比分析了剪力墙的承载力、延性、刚度及其衰减过程、滞回特性、耗能能力及破坏特征,建立了钢管混凝土边框组合剪力墙的承载力计算模型,计算结果与实测结果符合较好。研究表明:在高轴压比下钢管混凝土边框组合剪力墙与普通剪力墙相比抗震性能显著提高。  相似文献   

17.
Seismic performance of exterior beam–column subassemblages of reinforced concrete structure designed and detailed on the basis of the provisions of Eurocode and Indian Standards at different stages of their evolution is evaluated. Performance of the subassemblages designed and detailed according to the three different stages of codal evolution (gravity load design, ‘Nonductile’, and ‘Ductile’) is evaluated through analytical formulations and experimental investigations. In the ‘NonDuctile’ specimens, it has been observed that the shear distortion and degradation in stiffness and strength are significantly high. Performance of the ‘Ductile’ specimens based on Eurocode and Indian Standards is almost similar in terms of strength and stiffness degradation. Nevertheless, the specimen designed on the basis of Indian Standard shows higher energy dissipation at a given drift ratio. In the analytical study, shear and flexural failure of members of subassemblage and shear failure of the joint are considered as possible modes of failure of the beam–column subassemblage. For evaluating the shear strength of the joint region, a soften strut‐and‐tie model is used. Analytically obtained strengths based on the failure criteria of different components of the specimens have been first validated with experimental results and then used to determine the strength of the specimens. The investigation could indicate even the mode of failure at local level. It is utmost important to mention here that even the ductile specimens dissipate most of the energy through the development of damage in the joint region, which is neither desirable nor safe for the stability of whole structure. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

18.
The earthquake resistance of stacked precast concrete simple shear walls found typically in Large Panel buildings of the cross-wall type is studied. Physical model testing on a small shaking table facility and analytical techniques are compared. Results of the testing of four models to failure portrayed the non-linear effects of rocking and shear slip that were assumed in several analytical studies but were never before measured experimentally. The physical model studies are supplemented with an independent mathematical analysis using a modified version of the dynamic, non-linear computer code Drain 2–D. Correlation of the analytical and experimental results show that the computer study can be used to predict the overall shear wall response. Results of the small scale model and the mathematical model studies indicate that the simple shear wall behaves in a non-linear manner, even for low magnitudes of base acceleration. Non-linear effects, usually concentrated in only one or two joints, reduced force levels and increased displacements. The four small scale models that were tested withstood high magnitudes of base acceleration without collapse.  相似文献   

19.
全装配式预制混凝土结构梁柱组合件抗震性能试验研究   总被引:15,自引:1,他引:15  
采用足尺模型对比试验方法对现浇高强混凝土梁柱组合件、预制混凝土结构高强混凝土后浇整体式梁柱组合件和高强预制混凝土结构全装配式梁柱组合件在低周反复荷载作用下的开裂破坏形态、滞回特性、骨架曲线、强度与刚度退化特性、耗能能力、节点核心区域的剪切变形、梁端与柱端的转动变形等抗震性能指标进行了系统研究。结果表明:高强预制混凝土结构后浇整体式梁柱组合件与现浇高强混凝土结构梁柱组合件具有相同的抗震能力,全装配式预制混凝土梁柱组合件的抗震性能和主要抗震性能指标与现浇高强混凝土梁柱组合件和预制混凝土结构后浇整体式梁柱组合件存在明显的差异。对于实际工程应用,应采取必要措施增加全装配式节点的耗能能力。  相似文献   

20.
Reinforced concrete (RC) precast shear walls are extensively applied in practical engineering, owing to their fast construction speed. However, because of the transport conditions, RC precast shear walls have to be separated into small wall segments during the factory prefabrication procedure before being assembled on site. Typically, wet-type jointing methods are adopted to link the segments, which is time-consuming and results in unreliable post-pouring area strength. To overcome this problem, the novel scheme of the steel shear key (SSK) featuring steel shear panels and combined fillet and plug welding is proposed. Three RC precast shear wall specimens with different linking strength, termed as weakened SSK wall, standard SSK wall, and strengthened SSK wall, respectively, and an integrated shear wall specimen were designed. Quasi-static cyclic loading was applied to investigate the specimens' dynamic properties. The test results suggest the prefabricated wall segments equipped with SSKs showed reliable stiffness and bearing capacity and were improved in energy dissipation ability, compared with conventional shear walls. As the shear stiffness and number of equipped SSKs increased, the specimens exhibited higher strength, but their ductility and energy dissipation were slightly decreased. Most importantly, the standard SSK wall specimen could achieve satisfactory bearing capacity and deformability and is thus recommended for precast building structures. Finite element method (FEM) models were established to validate the test results, and parametric study analysis was conducted based on the coupling ratio of the SSK walls. Finally, an appropriate coupling ratio range is recommended for practical engineering applications.  相似文献   