首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 78 毫秒
1.
Purge and pump samples from screened wells reflect concentration averaging and contaminant redistribution by wellbore flow. These issues were assessed in a screened well at the Hanford Site by investigating the vertical profile of a technetium-99 plume in a conventional well under static and pumped conditions. Specific conductance and technetium-99 concentrations were well correlated, and this enabled measurement of specific conductance to be used as a surrogate for technetium-99 concentration. Time-series measurements were collected during purging from three specific conductance probes installed in the well at 1.2, 3.1, and 4.9 m below the static water level in a 7.7-m-deep screened well. The vertical contaminant profile adjacent to the well in the aquifer was calculated using the concentration profile in the well during pumping, the pumping flow rate, and a wellbore flow and mixing model. The plume was found to be stratified in the aquifer—the highest concentrations occurred adjacent to the upper part of the screened interval. The purge and pump sample concentrations were 41% to 58% of the calculated peak concentration in the aquifer. Plume stratification in the aquifer adjacent to the well screen became more pronounced as pumping continued. Extended pumping may have partially reversed the effect of contaminant redistribution in the aquifer by wellbore flow and allowed the stratification of the plume to be more observable. It was also found that the vertical profile of contamination in the well under static (i.e., nonpumping conditions) was not representative of the profile in the aquifer. Thus, passive or micropurge sampling techniques, which sample the wellbore water at different depths, would not yield results representative of the aquifer in this well.  相似文献   

2.
AGalerkin finite-element model coupled with a particle tracking routine was developed to analyze the flow and transport dynamics near a high-capacity irrigation well. The model was used to compute the head distribution around the pumping well, to determine the area of influence, and to define ground water flowlines during short-term pumping periods typical of those used to collect water quality samples from high-capacity wells. In addition to hypothetical example results, the model was used to qualitatively analyze data obtained from pump-and-sample experiments conducted in an unconfined alluvial aquifer within the Platte River valley of south-central Nebraska where nitrate-nitrogen (NO3-N) contamination is prevalent.
Simulation results of both the hypothetical and field cases suggest that short-term pumping events, impact a limited volume of aquifer. The area of influence and flowlines are affected by aquifer anisotropy, pumping rate, and well construction characteristics). Ground water above or below the screened intervals does not enter a partially penetrating well in anisotropic aquifers. In aquifers where NO3-N concentration varies vertically and horizontally, waler quality samples from an irrigation, or other high-capacity, well provide only limited information about ground water contamination. A numerical model is thus recommended for calculating the area of influence and determining flowlines around high-capacity wells so that information derived from water quality samples collected at the wellhead can be better interpreted.  相似文献   

3.
Characterization of a multilayer aquifer using open well dilution tests   总被引:1,自引:0,他引:1  
West LJ  Odling NE 《Ground water》2007,45(1):74-84
An approach to characterization of multilayer aquifer systems using open well borehole dilution is described. The approach involves measuring observation well flow velocities while a nearby extraction well is pumped by introducing a saline tracer into observation wells and collecting dilution vs. depth profiles. Inspection of tracer profile evolution allows discrete permeable layers within the aquifer to be identified. Dilution profiles for well sections between permeable layers are then converted into vertical borehole flow velocities and their evolution, using an analytic solution to the advection-dispersion equation applied to borehole flow. The dilution approach is potentially able to measure much smaller flow velocities that would be detectable using flowmeters. Vertical flow velocity data from the observation wells are then matched to those generated using a hydraulic model of the aquifer system, "shorted" by the observation wells, to yield the hydraulic properties of the constituent layers. Observation well flow monitoring of pumping tests represents a cost-effective alternative or preliminary approach to pump testing each layer of a multilayer aquifer system separately using straddle packers or screened wells and requires no prior knowledge of permeable layer depths and thicknesses. The modification described here, of using tracer dilution rather than flowmeter logging to obtain well flow velocities, allows the approach to be extended to greater well separations, thus characterizing a larger volume of the aquifer. An example of the application of this approach to a multilayer Chalk Aquifer in Yorkshire, Northeast England, is presented.  相似文献   

4.
One of the more common techniques for controlling the migration of contaminant plumes is the use of pumping wells to produce desired changes in local flow rates and hydraulic gradients. When seeking to optimize an array of pumping well locations and discharge rates, it is important to consider the effects that non-ideal aquifer conditions, well construction and demographic constraints produce. Heterogeneous and anisotropic aquifer conditions seriously complicate siting and discharge rate requirements for pumping wells because of the distorted cones of depression that result from withdrawing water in such settings. Proper screen selection, gravel pack emplacement and well development are crucial factors affecting the operational characteristics and economics of pumping wells; these factors are generally recognized, though often undervalued. The impacts that well depth and diameter, and screen length and position have on the effectiveness of pumping efforts are also often undervalued, with detrimental consequences. Perhaps the most difficult problems to overcome in designing pumping schemes, however, are posed by demographic constraints. Denial of property access, vandalism and the unpredictability of nearby water supply and irrigation pumpage tend to wreak havoc with the best of pumping strategies.  相似文献   

5.
An Analysis of Low-Flow Ground Water Sampling Methodology   总被引:1,自引:0,他引:1  
Low-flow ground water sampling methodology can minimize well disturbance and aggravated colloid transport into samples obtained from monitoring wells. However, in low hydraulic conductivity formations, low-flow sampling methodology can cause excessive drawdown that can result in screen desaturation and high ground water velocities in the vicinity of the well, causing unwanted colloid and soil transport into ground water samples taken from the well. Ground water velocities may increase several fold above that of the natural setting. To examine the drawdown behavior of a monitoring well, mathematical relationships can be developed that allow prediction of the steady-state drawdown for constant low-flow pumping rates based on well geometry and aquifer properties. The equations also estimate the time necessary to reach drawdown equilibrium. These same equations can be used to estimate the relative contribution of water entering a sampling device from either the well standpipe or the aquifer. Such equations can be useful in planning a low-flow sampling program and may suggest when to collect a water sample. In low hydraulic conductivity formations, the equations suggest that drawdown may not stabilize for well depths, violating the minimal drawdown requirement of the low-flow technique. In such cases, it may be more appropriate to collect a slug or passive sample from the well screen, under the assumption that the water in the well screen is in equilibrium with the surrounding aquifer.  相似文献   

6.
Siting wells near streams requires an accurate estimate of the quantity of water derived from the river due to pumping. A number of hydrogeological and hydraulic parameters influence this value. This study estimates stream depletion under steady-state conditions for a variety of hydrogeological systems. A finite differences model was used to analyze several hydrogeological situations, and for each of these the stream depletion was estimated using an advective transport method. An empirical equation for stream depletion was obtained for the case of a stream that partially penetrates the aquifer and a pumping well that is screened over a portion of the aquifer. The derived equation, which is valid for both isotropic and anisotropic conditions, expresses stream depletion as a function of the unit inflow to the river, the discharge of the pumping well, the well screen length, the distance between the river and pumping well, the wetted perimeter, and a new parameter called "overlap," which is defined to be the distance between the riverbed and the top of well screen. The overlap parameter makes it possible to consider indirectly the vertical component of flow, which is accentuated when the well is screened below the streambed. The formula proposed here should be useful in deciding where to locate a pumping well and to decide the appropriate length of its screen.  相似文献   

7.
Monitoring well interception with fractures in clayey till   总被引:1,自引:0,他引:1  
When using monitoring wells for investigation of contaminant sources in clayey till, there is a high risk that fractures may cause mobile contaminants to bypass the monitoring wells. This paper indicates that the probability of interception between monitoring wells and hydraulic conductive fractures is often significantly less than 50%. Based on a field experiment and application of a calibrated discrete fracture matrix diffusion numerical model (FRAC3Dvs), the paper also evaluates pesticide-monitoring results for different positions of monitoring well screen relative to fractures. For well screens situated 0.25 and 2 m from a conductive fracture, the first concentrations of the pesticide metabolite (2,6 dichlorobenzamide, "BAM") would be measured two years and 18 years, respectively, after the contaminant had been transported into an underlying aquifer. In this way, underlying aquifers may be subjected to contamination by downward moving contamination without being observed in monitoring wells in the till.  相似文献   

8.
Arsenic in groundwater is a serious problem in New England, particularly for domestic well owners drawing water from bedrock aquifers. The overlying glacial aquifer generally has waters with low arsenic concentrations but is less used because of frequent loss of well water during dry periods and the vulnerability to surface‐sourced bacterial contamination. An alternative, novel design for shallow wells in glacial aquifers is intended to draw water primarily from unconsolidated glacial deposits, while being resistant to drought conditions and surface contamination. Its use could greatly reduce exposure to arsenic through drinking water for domestic use. Hypothetical numerical models were used to investigate the potential hydraulic performance of the new well design in reducing arsenic exposure. The aquifer system was divided into two parts, an upper section representing the glacial sediments and a lower section representing the bedrock. The location of the well, recharge conditions, and hydraulic properties were systematically varied in a series of simulations and the potential for arsenic contamination was quantified by analyzing groundwater flow paths to the well. The greatest risk of arsenic contamination occurred when the hydraulic conductivity of the bedrock aquifer was high, or where there was upward flow from the bedrock aquifer because of the position of the well in the flow system.  相似文献   

9.
A confined aquifer may become unconfined near the pumping wells when the water level falls below the confining unit in the case where the pumping rate is great and the excess hydraulic head over the top of the aquifer is small. Girinskii's potential function is applied to analyze the steady ground water flow induced by pumping wells with a constant-head boundary in a mixed confined-unconfined aquifer. The solution of the single-well problem is derived, and the critical radial distance at which the flow changes from confined to unconfined condition is obtained. Using image wells and the superposition method, an analytic solution is presented to study steady ground water flow induced by a group of pumping wells in an aquifer bounded by a river with constant head. A dimensionless function is introduced to determine whether a water table condition exists or not near the pumping wells. An example with three pumping wells is used to demonstrate the patterns of potentiometric surface and development of water table around the wells.  相似文献   

10.
A main purpose of groundwater inverse modeling lies in estimating the hydraulic conductivity field of an aquifer. Traditionally, hydraulic head measurements, possibly obtained in tomographic setups, are used as data. Because the groundwater flow equation is diffusive, many pumping and observation wells would be necessary to obtain a high resolution of hydraulic conductivity, which is typically not possible. We suggest performing heat tracer tests using the same already installed pumping wells and thermometers in observation planes to amend the hydraulic head data set by the arrival times of the heat signals. For each tomographic combinations of wells, we recommend installing an outer pair of pumping wells, generating artificial ambient flow, and an inner well pair in which the tests are performed. We jointly invert heads and thermal arrival times in 3-D by the quasi-linear geostatistical approach using an efficiently parallelized code running on a mid-range cluster. In the present study, we evaluate the value of heat tracer versus head data in a synthetic test case, where the estimated fields can be compared to the synthetic truth. Because the sensitivity patterns of the thermal arrival times differ from those of head measurements, the resolved variance in the estimated field is 6 to 10 times higher in the joint inversion in comparison to inverting head data only. Also, in contrast to head measurements, reversing the flow field and repeating the heat-tracer test improves the estimate in terms of reducing the estimation variance of the estimate. Based on the synthetic test case, we recommend performing the tests in four principal directions, requiring in total eight pumping wells and four intersecting observation planes for heads and temperature in each direction.  相似文献   

11.
The vertical variation of drawdown around pumping wells generates an induced flow in the observation wells. A set of governing equations is presented to couple the drawdown variation and the vertical flux distribution in observation wells. A numerical example is performed to justify the governing equations and to verify the solution methods used by the simulation software WT. The example analyzes the effect of skin loss, wellbore storage, and vertical segmentation on the drawdown and induced flow in observation well during pumping. The evaluation of the Fairborn pumping test involves a vertically homogeneous and anisotropic water table aquifer, uniform well‐face drawdown conditions in the pumping well and simulation of the drawdown evolution in the observation well with and without the effect of induced flow. The computer calibrations resulted in small differences between the measured and simulated drawdown curves.  相似文献   

12.
This paper derives an equivalent of Darcian Theis solution for non-Darcian flow induced by constant rate pumping of a well in a confined aquifer. The derivation, which is valid at later times only, is original. It utilizes Izbash's equation. This introduces an additional parameter to Darcian condition, namely, empirical exponent. The solution is a non-Drcian equivalent of Jacob straight line method for analyzing pumping tests at late times. It can be used to determine aquifer parameters: storativity, analogous hydraulic conductivity, and empirical exponent. However, while the Jacob method requires a minimum of only one pumping test with one observation well, the additional parameter in the present solution means that a minimum of two observation wells in one test or two pumping tests at different rates with one observation well are required. The derived solution is applied to a case study at Plomeur in Brittany, France, and is shown to provide a practical and efficient method for analyzing pumping tests where non-Darcian groundwater flow occurs.  相似文献   

13.
Bayer P  Finkel M 《Ground water》2006,44(2):234-243
We investigate the performance of vertical hydraulic barriers in combination with extraction wells for the partial hydraulic isolation of contaminated aquifer areas. The potential advantage of such combinations compared to a conventional pump-and-treat system has already been demonstrated in a previous study. Here we extend the scope of the performance analysis to the impact of uncertainty in the regional flow direction as well as to highly heterogeneous aquifer transmissivity distributions. In addition, two new well-barrier scenarios are proposed and analyzed. The hydraulic efficiency of the scenarios is rated based on the expected (mean) reduction of the pumping rate that is required to achieve downgradient contaminant capture. The uncertain spatial distribution of aquifer transmissivity is considered by means of unconditioned Monte Carlo simulations. The significance of uncertain background flow conditions is incorporated by computing minimized pumping rates for deviations of the regional flow direction up to 30 degrees from a normative base case. The results give an answer on how pumping rates have to be changed for each barrier-well combination in order to achieve robust systems. It is exposed that in comparison to installing exclusively wells, the barrier-supported approach generally yields savings in the (average) pumping rate. The particular efficiency is shown to be highly dependent on the interaction of variance and integral scale of transmissivity distribution, well and barrier position, as well as direction of background flow.  相似文献   

14.
A common assumption of ground water models formulated using a block-centered finite-difference method is that a well is located at the center of a cell regardless of its actual location. Due to this assumption, errors are introduced in the spatial distribution of simulated heads. This paper presents an alternative approach for assigning the pumping rates of wells that are located off cell centers. This approach consists of assigning the pumping rate not only to the cell in which the well is located but also to adjacent cells, taking into account the length of the well screen, the hydraulic conductivity, and the distance from the well to the center of its cell. The advantage of this alternative approach over the conventional one is illustrated with a test problem of a synthetic aquifer. Statistical measures of error indicate a much better model fit when pumping rates of wells are distributed over several cells.  相似文献   

15.
This paper deals with water pumping cost minimization, in a confined infinite aquifer, proposing an alternate pulsed pumping schedule. The transient flow analysis is conducted for two wells with equal pumping rates. Specifically, two pumping schedules are analytically compared. In the first case, well users pump simultaneously, and in the second one they cooperate so that they pump alternately. This paper proves that the proposed alternate pumping schedule works as a stabilizer, reducing the high hydraulic drawdowns values, regardless of the aquifer characteristics. Moreover, pumping alternately is better in terms of pumping cost, compared to simultaneous pumping, though benefit become negligible as distance between wells becomes large. Two simplified equations are proposed, one to find the difference of the hydraulic drawdowns between the two pumping schedules and the other one to find the economic benefit of each well from cooperation. The equations are finally applied to a number of cases and their results are compared to the results obtained from an algorithm created to calculate the hydraulic drawdowns and the pumping cost, using the Theis equation. The results can be very useful in irrigation scheduling, as they can be applied to systems of well users/farmers, to reduce pumping cost.  相似文献   

16.
Pumping test evaluation of stream depletion parameters   总被引:1,自引:0,他引:1  
Lough HK  Hunt B 《Ground water》2006,44(4):540-546
  相似文献   

17.
In order to understand the flow pattern around a pumping well partially penetrating a vertically extensive aquifer, a specially designed pumping test was carried out in Pakistan. In this paper salient features of the test have been described. The spatial distributions of drawdown have been shown graphically. Some of the preliminary conclusions made from the drawdown pattern include:
  • • The distance beyond which the flow is likely to be horizontal increases with decrease in the degree of aquifer penetration.
  • • In equidistant observation wells open at different depths, (1) the drawdowns tend to merge at larger times, provided the observation point is located within the screened section of the aquifer; (2) the less the depth of penetration is, the earlier the drawdowns start merging; and (3) the initial rate of drawdown near the aquifer top is slow but catches up with time to exceed those at deeper points.
  相似文献   

18.
Numerical flow models can be a useful tool for dimensioning water wells and to investigate the hydraulics in their near‐field. Fully laminar flow can be assumed for all models calculated up to the screen. Therefore models can be used to predict—at least qualitatively, neglecting turbulent losses inside the well—the spatial distribution of inflow into the well and the overall hydraulic performance of different combinations of aquifer parameters and technical installations. Models for both horizontal (plan view) and vertical flow (cross section) to wells were calculated for a variety of setups. For the latter, this included variations of hydraulic conductivity of the screen, pump position, and aquifer heterogeneity. Models of suction flow control devices showed that they indeed can homogenize inflow, albeit at the cost of elevated entrance losses.  相似文献   

19.
Zhang J  Randall G  Wei X 《Ground water》2012,50(3):464-471
In solving groundwater transport problems with numerical models, the computation time (CPU processing time) of transport simulation is approximately inversely proportional to the transport time-step size. Therefore, large time-step sizes are favorable for achieving short computation time. However, transport time-step size must be sufficiently small to avoid numerical instability if an explicit scheme is used (and to guarantee enough model accuracy if an implicit scheme is used). For a transport model involving groundwater pumping, a small transport time-step size is often required due to the high groundwater velocities near the pumping well. Small grid spacing often specified near the pumping well also limits the time-step size. This paper presents a method to increase transport time-step size in a transport model when groundwater pumping is simulated. The key to this approach is to numerically decrease the groundwater seepage velocities in grid cells near the pumping well by increasing the effective porosity so that the transport time-step size can be increased without violating stability constraints. Numerical tests reveal that by using the proposed method, the computation time of transport simulation can be reduced significantly, while the transport simulation results change very little.  相似文献   

20.
An approach is presented to determine the seasonal variations in travel time in a bank filtration system using a passive heat tracer test. The temperature in the aquifer varies seasonally because of temperature variations of the infiltrating surface water and at the soil surface. Temperature was measured with distributed temperature sensing along fiber optic cables that were inserted vertically into the aquifer with direct push equipment. The approach was applied to a bank filtration system consisting of a sequence of alternating, elongated recharge basins and rows of recovery wells. A SEAWAT model was developed to simulate coupled flow and heat transport. The model of a two‐dimensional vertical cross section is able to simulate the temperature of the water at the well and the measured vertical temperature profiles reasonably well. MODPATH was used to compute flowpaths and the travel time distribution. At the study site, temporal variation of the pumping discharge was the dominant factor influencing the travel time distribution. For an equivalent system with a constant pumping rate, variations in the travel time distribution are caused by variations in the temperature‐dependent viscosity. As a result, travel times increase in the winter, when a larger fraction of the water travels through the warmer, lower part of the aquifer, and decrease in the summer, when the upper part of the aquifer is warmer.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号