首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Water levels and water quality of open borehole wells in fractured bedrock are flow-weighted averages that are a function of the hydraulic heads and transmissivities of water contributing fractures, properties that are rarely known. Without such knowledge using water levels and water quality data from fractured bedrock wells to assess groundwater flow and contaminant conditions can be highly misleading. This study demonstrates a cost-effective single packer method to determine the hydraulic heads and transmissivities of water contributing fracture zones in crystalline bedrock wells. The method entails inflating a pipe plug to isolate sections of an open borehole at different depths and monitoring changes in the water level with time. At each depth, the change in water level with time was used to determine the sum of fracture transmissivities above the packer and then to solve for individual fracture transmissivity. Steady-state wellbore heads along with the transmissivities were used to determine individual fracture heads using the weighted average head equation. The method was tested in five wells in crystalline bedrock located at the University of Connecticut in Storrs. The single packer head and transmissivity results were found to agree closely with those determined using conventional logging methods and the dissolved oxygen alteration method. The method appears to be a simple and cost-effective alternative in obtaining important information on flow conditions in fractured crystalline bedrock wells.  相似文献   

2.
Groundwater sampling from open boreholes in fractured‐rock aquifers is particularly challenging because of mixing and dilution of fluid within the borehole from multiple fractures. This note presents an alternative to traditional sampling in open boreholes with packer assemblies. The alternative system called ZONFLO (zonal flow) is based on hydraulic control of borehole flow conditions. Fluid from discrete fractures zones are hydraulically isolated allowing for the collection of representative samples. In rough‐faced open boreholes and formations with less competent rock, hydraulic containment may offer an attractive alternative to physical containment with packers. Preliminary test results indicate a discrete zone can be effectively hydraulically isolated from other zones within a borehole for the purpose of groundwater sampling using this new method.  相似文献   

3.
Volatile organic compounds delected in ground water from wells at Test Area North (TAN) at the Idaho National Engineering Laboratory (INEL) prompted RCRA facility investigations in 1989 and 1990 and a CERCLA-driven RI/FS in 1992. In order to address ground water treatment feasibility, one of the main objectives, of the 1992 remedial investigation was to determine the vertical extent of ground water contamination, where the principle contaminant, of concern is trichloroethylene (TCE). It was hypothesized that a sedimentary interbed at depth in the fractured basalt aquifer could be inhibiting vertical migration of contaminants to lower aquifers. Due to the high cost of drilling and installation of ground water monitoring wells at this facility (greater than $100,000 per well), a real time method was proposed for obtaining and analyzing ground water samples during drilling to allow accurate placement of well screens in zones of predicted VOC contamination. This method utilized an inflatable pump packer pressure transducer system interfaced with a datalogger and PC at land surface. This arrangement allowed for real lime monitoring of hydraulic head above and below the packer to detect leakage around the packer during pumping and enabled collection of head data during pumping for estimating hydrologic properties. Analytical results were obtained in about an hour from an on-site mobile laboratory equipped with a gas chromalograplvmass spectrometer (GC/MS). With the hydrologic and analytical results in hand, a decision was made to either complete the well or continue drilling to the next test zone. In almost every case, analytical results of ground water samples taken from the newly installed wells closely replicated the water quality of ground water samples obtained through the pump packer system.  相似文献   

4.
Vidstrand P 《Ground water》2001,39(3):401-407
A hydraulic field test program was performed at a hard rock laboratory (Asp? HRL) on the Swedish east coast to test upscaling theories. The test program investigated the rock volume around a borehole located at a depth of approximately 340 m below sea level. Hydraulic packer tests were performed at various scales, from 2 m to the entire borehole length of 296 m. From this set of data the predictive ability of different upscaling methods could be evaluated. The comparison of the evaluated "true" field scale hydraulic conductivity with the upscaled hydraulic conductivity yielded that the majority of the upscaling methods tested in this paper predict the large scale values with significant accuracy. However, the ability to predict rapidly decreases when the variance of the natural logarithm of hydraulic conductivity of the subsamples is larger than one. Such a variance is consistently found in the crystalline rocks at the tested site at the 2 m scale. However, at scales of 10 m and larger, a variance larger than one is uncommon. Therefore, it is concluded that there exists a smallest possible scale for use of hydraulic pumping test results for estimating the effective hydraulic conductivity at scales typical for regional flow.  相似文献   

5.
Remote sensing and geoelectrical methods were used to find water-bearing fractures in the Scituate granite under the Central Landfill of Rhode Island. These studies were necessary to evaluate the integrity of the sanitary landfill and for planning safe landfill extensions. The most useful results were obtained with fracture trace analysis using Landsat and SLAR imagery in combination with ground-based resistivity measurements using Schlumberger vertical electrical soundings based on the assumption of horizontally layered strata. Test borings and packer tests confirmed, in the presence of a lineament and low bedrock resistivity, the probable existence of high bedrock fracture density and high average hydraulic conductivity. However, not every lineament was found to be associated with high fracture density and high hydraulic conductivity. Lineaments alone are not a reliable basis for characterising a landfill site as being affected by fractured bedrock. Horizontal fractures were found in borings located away from lineaments. High values of hydraulic conductivity were correlated with low bedrock resistivities. Bedrock resistivities between 60 and 700 Ω m were associated with average hydraulic conductivities between 4 and 60 cm/day. In some cases very low resistivities were confined to the upper part of the bedrock where the hydraulic conductivity was very large. These types of fractures apparently become narrower in aperture with depth. Bedrock zones having resistivities greater than 1000 Ω m showed, without exception, no flow to the test wells. Plots of bedrock resistivity versus the average hydraulic conductivity indicate that the resistivity decreases with increasing hydraulic conductivity. This relationship is inverse to that found in most unconsolidated sediments and is useful for estimating the hydraulic conductivity in groundwater surveys in fractured bedrock. In appropriate settings such as the Central Landfill site in New England, this electric-hydraulic correlation relationship, supplemented by lineament trace analysis, can be used effectively to estimate the hydraulic conductivity in bedrock from only a limited number of resistivity depth soundings and test wells.  相似文献   

6.
A suction side sample collector (SSSC) is a contrivance installed hydraulically ahead of the intake port of a pumping device. This paper describes construction and operational details of SSSCs fitted to a submersible pump with packer for use in a 6-inch cased borehole, an air lift pump with packer for use in a 1-inch or 2.5-inch cased borehole, a bladder pump for use in a casing of 2-inch or greater diameter, and a jet pump with packer for use in a 2-inch cased borehole.
Each form of SSSC has been thoroughly tested in ground water quality sampling for volatile organic chemicals. Comparative data for samples collected with the SSSCs and conventional sample collecting gear are presented. The SSSC is demonstrated to be superior to other methods of collecting volatile organic chemical samples owing to its freedom from contamination by the pump delivery line and to its mode of collecting the sample from a position in the well remote from disturbance by the pumping technique.
SSSCs are conveniently decontaminated, easily transported, and can be used to deliver samples to the laboratory while still at formation pressure. The air-lift pumps, described in this paper for use with SSSCs in 1- and 2.5-inch casings, have pumping capacities greater than obtained by other methods that can operate in these small casings. Discharge rates of up to 2 gpm are routinely achieved with the 1-inch model and higher rates are common With the 2.5-inch model. The use of packers with these pumps reduces the time needed to replace the water in the casing with fresh water from the formation.  相似文献   

7.
Identifying connections in a fractured rock aquifer using ADFTs   总被引:1,自引:0,他引:1  
Halihan T  Love A  Sharp JM 《Ground water》2005,43(3):327-335
Fractured rock aquifers are difficult to characterize because of their extremely heterogeneous nature. Developing an understanding of fracture network hydraulic properties in these aquifers is difficult and time consuming, and field testing techniques for determining the location and connectivity of fractures in these aquifers are limited. In the Clare Valley, South Australia, well interference is an important issue for a major viticultural area that uses a fractured aquifer. Five fracture sets exist in the aquifer, all dipping > 25 degrees . In this setting, we evaluate the ability of steady-state asymmetric dipole-flow tests (ADFTs) to determine the connections between a test well and a set of piezometers. The procedure involves dividing a test well into two chambers using a single packer and pumping fluid from the upper chamber to the lower chamber. By conducting a series of tests at different packer elevations, an "input" signal is generated in fracture zones connected to the test well. By monitoring the "output" response of the hydraulic dipole field at piezometers, the connectivity of the fractures between the test well and piezometers can be determined. Results indicate the test well used in this study is connected in a complex three-dimensional geometry, with drawdown occurring above and below areas of potentiometric buildup. The ADFT method demonstrates that the aquifer evaluated in this study cannot be modeled effectively on the well scale using continuum flow models.  相似文献   

8.
Major challenges exist in delineating bedrock fracture zones because these cause abrupt changes in geological and hydrogeological properties over small distances. Borehole observations cannot sufficiently capture heterogeneity in these systems. Geophysical techniques offer the potential to image properties and processes in between boreholes. We used three‐dimensional cross borehole electrical resistivity tomography (ERT) in a 9 m (diameter) × 15 m well field to capture high‐resolution flow and transport processes in a fractured mudstone contaminated by chlorinated solvents, primarily trichloroethylene. Conductive (sodium bromide) and resistive (deionized water) injections were monitored in seven boreholes. Electrode arrays with isolation packers and fluid sampling ports were designed to enable acquisition of ERT measurements during pulsed tracer injections. Fracture zone locations and hydraulic pathways inferred from hydraulic head drawdown data were compared with electrical conductivity distributions from ERT measurements. Static ERT imaging has limited resolution to decipher individual fractures; however, these images showed alternating conductive and resistive zones, consistent with alternating laminated and massive mudstone units at the site. Tracer evolution and migration was clearly revealed in time‐lapse ERT images and supported by in situ borehole vertical apparent conductivity profiles collected during the pulsed tracer test. While water samples provided important local information at the extraction borehole, ERT delineated tracer migration over spatial scales capturing the primary hydrogeological heterogeneity controlling flow and transport. The fate of these tracer injections at this scale could not have been quantified using borehole logging and/or borehole sampling methods alone.  相似文献   

9.
Cautions and Suggestions for Geochemical Sampling in Fractured Rock   总被引:2,自引:0,他引:2  
Collecting water samples for geochemical analyses in open bedrock boreholes or in discrete intervals of boreholes intersected by multiple fractures is likely to yield ambiguous results for ground water chemistry because of the variability in the transmissivity, storativity, and hydraulic head of fractures intersecting the borehole. Interpreting chemical analyses of water samples collected in bedrock boreholes requires an understanding of the hydraulic conditions in the borehole under the ambient flow regime in the aquifer as well as during sampling. Pumping in open boreholes, regardless of the pumping rate and the location of the pump intake, first draws water from the borehole and then from fractures intersecting the borehole. The time at which the volumetric rate of water entering the borehole from fractures is approximately equal to the pumping rate can be identified by monitoring the logarithm of drawdown in the borehole as a function of the logarithm of time. Mixing of water entering the borehole from fractures with water in the borehole must be considered in estimating the time at which the pump discharge is representative of aquifer water. In boreholes intersected by multiple fractures, after the contribution from the borehole volume has diminished, the contribution of fractures to the pump discharge will be weighted according to their transmissivity, regardless of the location of the pump intake. This results in a flux-averaged concentration in the pump discharge that is biased by the chemical signature of those fractures with the highest transmissivity. Under conditions where the hydraulic head of fractures varies over the length of the borehole, open boreholes will be subject to ambient flow in the water column in the borehole. In some instances, the magnitude of the ambient flow may be similar to the designated pumping rate for collecting water samples for geochemical analyses. Under such conditions, the contributions to the pump discharge from individual fractures will be a function not only of the transmissivity of the fractures, but also of the distribution of hydraulic head in fractures intersecting the borehole. To reduce or eliminate the deleterious effects of conducting geochemical sampling in open boreholes, a straddle-packer apparatus that isolates a single fracture or a series of closely spaced fractures is recommended. It is also recommended that open boreholes be permanently outfitted with borehole packers or borehole liners in instances where maintaining the hydraulic and chemical stratification in the aquifer is of importance. In a field example, a comparison of results from sampling in an open borehole and in discrete intervals of the same borehole showed dramatic differences in the concentrations of chemical constituents in the water samples, even though chemical field parameters stabilized prior to both open borehole and discrete interval sampling.  相似文献   

10.
Geophysical well logging has been applied for fracture characterization in crystalline terrains by physical properties measurements and borehole wall imaging. Some of these methods can be applied to monitor pumping tests to identify fractures contributing to groundwater flow and, with this, determine hydraulic conductivity and transmissivity along the well. We present a procedure to identify fractures contributing to groundwater flow using spontaneous potential measurements generated by electrokinetic processes when the borehole water head is lowered and then monitored while recovering. The electrokinetic model for flow through a tabular gap is used to interpret the measured data and determine the water head difference that drives the flow through the fracture. We present preliminary results at a test site in crystalline rocks on the campus of the University of São Paulo.  相似文献   

11.
Measurement accuracy was increased by nearly one order of magnitude by outfitting the thermal-pulse flowmeter (TFM) with an inflatable packer. To accurately measure slow water velocities in boreholes greater than 15 cm diameter, it is necessary to divert borehole fluids through the TFM by inflating a packer. During calibration it was noted that the TFM's accuracy decreased as the borehole diameter increased. With Lhe packer inflated the TFM has a useful flow measurement range of 0.08 to 15 L/min (with flow velocities of 0.24 ± 0.012 cm/inin to 45.7 ± 0.61 cm/min, respectively, in 20-cm-diameter pipe), compared to 0.8 to 57 L/min for a packcrless TFM. A computer interlace was added to the TFM to provide a real-time graphical display of the differential voltage output from the TFM, a running mean and standard deviation of the pulse-response time, and a mean flow rate and velocity based on calibration curve fits.  相似文献   

12.
Fracture aperture is an important transport property in subsurface hydrology because it influences well productivity and the volume of the water resource. Nuclear magnetic resonance (NMR) well logging measures the hydrogen‐bearing fluid molecules in porous or fractured strata, and the NMR signal intensity increases with the amount of fluid in the sensed region of the NMR sonde. Fluid confined in a large fracture of >>0.2 mm in aperture has T2 (i.e. spin‐spin relaxation time) values as long as those of the bulk fluid. The bulk‐fluid porosity (i.e. porosity calculated using this long T2 component in a T2 histogram data) increases linearly with aperture. Therefore, NMR logging enables quantitative estimation of fracture apertures of >>0.2 mm using the bulk‐fluid porosity data if the calibration of the NMR sonde is performed adequately. We applied NMR logging to a borehole in a Holocene andesite lava at Sumikawa, Japan, to estimate the aperture of open fractures within the lava. A test well of 100 m depth and 20 cm diameter, filled with bentonite drilling mud, was scanned with an NMR sonde to obtain a profile of the porosity and the T2 histogram of the andesite. The bulk‐fluid porosity was calculated from the T2 histogram data, as the porosity at which the T2 value is larger than or equal to a threshold T2 of bulk bentonite mud. The bulk‐fluid porosity of a specific inclined fracture responsible for the total loss of circulation at 61.2 m depth during drilling was calculated assuming a threshold or T2 cut‐off of 33 ms, and again for a cut‐off of 100 ms. Calibration of the NMR sensor in a laboratory and measurement of the fracture dip angle by electrical microimaging logging enabled us to estimate the fracture aperture as 1.7 cm, assuming a T2 cut‐off of 33 ms, or 1.6 cm for a T2 cut‐off of 100 ms. The method of aperture determination described in this study is independent of fluid species and lithology, and is applicable to various hydrogen‐bearing borehole fluids (clean water, mud and oil) and geological settings.  相似文献   

13.
In any type of groundwater transport problem (contaminant solutes, heat, etc.), knowledge of the location and properties of pathways of increased hydraulic conductivity is essential. However, answering such questions in strongly heterogeneous media, such as fractured rock, can be very difficult and budget-intensive with standard geophysical or hydrogeological field investigations. We present a new testing concept and analysis procedure based on a time sequence of wellbore electric conductivity logs, which provides the exact location and the outflow parameters (transmissivity, formation fluid conductivity) of flowing features (fractures, faults, layers) intercepted by the borehole.Previously the quantitative analysis of this time sequence of electrical conductivity logs was based on a code, called BORE, used to simulate borehole fluid conductivity profiles given these parameters. The present report describes a new direct (not iterative) method for analyzing a short time series of electric conductivity logs which is based on moment quantities of the individual outflow peaks, and applies it to synthetic as well as to field data. The results of the method are promising and are discussed in terms of the method's advantages and limitations. In particular it is shown that the method is capable of reproducing hydraulic properties derived from packer tests well within a factor of three, which is below the range of what is recognized as the accuracy of packer tests themselves. Furthermore the new method is much quicker than the previously used iterative fitting procedure and is even capable of handling transient fracture outflow conditions.  相似文献   

14.
Reverse water‐level fluctuations have been widely observed in aquitards or aquifers separated from a pumped confined aquifer (Noordbergum effect) immediately after the initiation of pumping. This same reverse fluctuation has been observed in a fractured crystalline‐rock aquifer at the Coles Hill uranium site in Virginia in which the reverse water‐level response occurs within a pumped fracture and results from an instantaneous strain response to pumping that precedes the pore‐pressure response in observation wells of sufficient distance from the pumped well. This response is referred to as the Mandel‐Cryer effect. The unique aspect of this water level rise during a controlled 24 h pumping test was that the reverse water levels lasted for approximately 100 min and reached a magnitude of nearly 1 cm prior to a typical drawdown response. The duration and magnitude of the response reflects the poromechanical properties of the fractured host rock and hydraulic properties of the pumped fracture. An axisymmetric flow and deformation model were developed using Biot2 in an effort to simulate the observed water‐level response along an assumed 0.5 to 1.0 cm aperture horizontal fracture 176 m from the pumping well and to identify the importance of the poroelastic effect. Results indicate that traditional aquifer‐testing methods that ignore the poromechanical response are not significantly different than results that include the response. However, the poroelastic effect allows for more accurate and efficient parameter calibration.  相似文献   

15.
Site characterization in densely fractured dolomite: comparison of methods   总被引:2,自引:0,他引:2  
One of the challenges in characterizing fractured-rock aquifers is determining whether the equivalent porous medium approximation is valid at the problem scale. Detailed hydrogeologic characterization completed at a small study site in a densely fractured dolomite has yielded an extensive data set that was used to evaluate the utility of the continuum and discrete-fracture approaches to aquifer characterization. There are two near-vertical sets of fractures at the site; near-horizontal bedding-plane partings constitute a third fracture set. Eighteen boreholes, including five coreholes, were drilled to a depth of approximately 10.6 m. Borehole geophysical logs revealed several laterally extensive horizontal fractures and dissolution zones. Flowmeter and short-interval packer testing identified which of these features were hydraulically important. A monitoring system, consisting of short-interval piezometers and multilevel samplers, was designed to monitor four horizontal fractures and two dissolution zones. The resulting network consisted of >70 sampling points and allowed detailed monitoring of head distributions in three dimensions. Comparison of distributions of hydraulic head and hydraulic conductivity determined by these two approaches suggests that even in a densely fractured-carbonate aquifer, a characterization approach using traditional long-interval monitoring wells is inadequate to characterize ground water movement for the purposes of regulatory monitoring or site remediation. In addition, traditional multiwell pumping tests yield an average or bulk hydraulic conductivity that is not adequate for predicting rapid ground water travel times through the fracture network, and the pumping test response does not appear to be an adequate tool for assessing whether the porous medium approximation is valid.  相似文献   

16.
The progressive packer/zone sampling method was used to identify the bottom of a plume of volatile organic compounds (VOCs) in the parts-per-million (ppm) range using one well in each of three separate locations. The method involves progressively drilling a 20-foot length of borehole through casing, setting an inflatable packer at the top of the drilled zone, purging the zone of three volumes of water using the airlift method, sampling the zone in situ through the packer string using a bailer, then repeating the procedure.
A plume consisting of chlorinated VOCs, alcohols, and vinyl chloride occurs in a low-yielding fractured bedrock aquifer located in the Passaic Formation at a site in central New Jersey. The thickness of the plume in total VOC concentrations exceeding 1 ppm was determined using the progressive packer/zone sampling method to a depth of 200 feet. The first borehole was completed as a monitoring well in the "hottest" zone encountered during testing. Additional wells were then clustered with this exploratory well to delineate the plume in the parts-per-billion (ppb) range. Cross contamination from previously sampled zones was not a problem as long as total VOCs in the ppm range were targeted and the sample interval was properly purged.
Instead of using a multiple well cluster consisting of an indefinite number of wells to determine the bulk thickness of a plume at a specific location, information from one borehole may suffice during the exploratory phase. Costs to the client and cross contamination potential to the aquifer can be minimized by limiting the number of boreholes needed for vertical delineation.  相似文献   

17.
Ground water/surface water interaction in a fractured rock aquifer   总被引:1,自引:0,他引:1  
In a recent field study of ground water/surface water interaction between a bedrock stream and an underlying fractured rock aquifer, it was determined that the majority of ground water discharge occurred through sparsely located vertical fractures. In this paper, the dominant mechanisms governing ground water/surface water exchange in such an environment are investigated using a numerical model. The study was conducted using several conceptual models based on the field study results. Although the field results provided the motivation for the modeling study, it was not intended to match modeling and field results directly. In addition, the extent of capture zones for discharging or recharging fractures was explored. The results of this study are intended to provide a better understanding of contaminant migration in the vicinity of bedrock streams. Based on the numerical results, the rate of ground water discharge (or recharge) was found to depend on the aperture size of the discharging feature, and on the distribution of hydraulic head with depth within the fracture network. It was determined that the extent of both the capture zone and reverse capture zone for an individual fracture can be extremely large, and will be determined by the height of the stream stage, the fracture apertures of the network, and the hydraulic-head distribution within the network. Because both the stream stage and the hydraulic-head distribution are transient, the size of the capture zone and/or the reverse capture zone for an individual fracture may change significantly over time. As a result, the migration path for contaminants within the fracture network and between the surface and subsurface will also vary significantly with time.  相似文献   

18.
The electromagnetic borehole flowmeter (EBF) is finding increasing application as a method for measuring hydraulic conductivity (K) distributions. A recent paper details an experimental/theoretical study of the effect of in-well hydraulics on calculated K distributions based on EBF measurements (Dinwiddie et al. 1999). Results showed that minimizing head loss associated with flow through the meter was the key to producing accurate K values. Using the same experimental procedures, the previous study has been extended to develop data from a larger diameter (1 inch) EBF, and to determine if an EBF can be calibrated effectively without using an inflatable packer to force all flow through the meter annulus. Both experiments were aimed at producing low head loss conditions. Results show that overall calibration can be accomplished in the absence of a packer, which reduces head losses to nonmeasurable levels, and use of the 1-inch EBF with a packer reduces head losses by a factor of 16 when compared with the 0.5-inch EBF studied by Dinwiddie et al. (1999).  相似文献   

19.
Advanced borehole-geophysical methods were used to assess the geohydrology of fractured crystalline bedrock at five test boreholes in southwestern Manhattan Island, New York, in preparation for construction of a third water tunnel for New York City. The boreholes penetrated gneiss and other crystalline bedrock that has an overall southwest to northwest dipping foliation with a 60° dip. Most of the fractures encountered are either nearly horizontal or have moderate northwest dip azimuths. Fracture indexes range from 0.25 to 0.44 fracture per foot (0.3 m) of borehole.
Electromagnetic (EM) and heat-pulse flowmeter logs obtained under ambient and pumping conditions, together with other geophysical logs, indicate transmissive fracture zones in each borehole. Pumping tests of each borehole indicated transmissivity ranges from <2 to 360 ft2/day (0.2 to 33 m2/day). Ground water appears to flow within an interconnected fracture network toward the south and west within the study area. No correlation was indicated between the fracture index and the total borehole transmissivity.  相似文献   

20.
Fracture identification is important for the evaluation of carbonate reservoirs. However, conventional logging equipment has small depth of investigation and cannot detect rock fractures more than three meters away from the borehole. Remote acoustic logging uses phase-controlled array-transmitting and long sound probes that increase the depth of investigation. The interpretation of logging data with respect to fractures is typically guided by practical experience rather than theory and is often ambiguous. We use remote acoustic reflection logging data and high-order finite-difference approximations in the forward modeling and prestack reverse-time migration to image fractures. First, we perform forward modeling of the fracture responses as a function of the fracture–borehole wall distance, aperture, and dip angle. Second, we extract the energy intensity within the imaging area to determine whether the fracture can be identified as the formation velocity is varied. Finally, we evaluate the effect of the fracture–borehole distance, fracture aperture, and dip angle on fracture identification.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号