首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
In this study, we use a linearization procedure and a finite difference method to solve non-Darcian flow to a well in an aquifer–aquitard system. The leakage effect is considered. Flow in the aquifer is assumed to be non-Darcian and horizontal, whereas flow in the aquitard is assumed to be Darcian and vertical. The Izbash equation [Izbash SV. O filtracii V Kropnozernstom Materiale. USSR: Leningrad; 1931 [in Russian]] is employed to describe the non-Darcian flow. The wellbore storage is also considered in this study. An approximate semi-analytical solution has been obtained by the linearization procedure, and a numerical solution has been obtained by using a finite difference method. The previous solutions for Darcian flow case and non-Darcian flow case without leakage can be described as special cases of the new solutions. The error caused by the linearization procedure has also been analyzed. The relative error caused by the linearization procedure is nearly 100% at early times, and decreases to zero at late times. We have also compared the results in this study with Wen et al. [Wen Z, Huang G, Zhan H. A numerical solution for non-Darcian flow to a well in a confined aquifer using the power law function. J Hydrol, 2008d [in revision]] in which the leakage effect is not considered, and Hantush and Jacob [Hantush MS, Jacob CE. Non-steady radial flow in an infinite leaky aquifer. Trans Am Geophys Union 1955;36(1):95–100] who investigated a similar problem in Darcian flow case. The comparison of this study and Wen et al. (2008d) indicates the dimensionless drawdown in the aquifer with leakage is less than that without leakage, and the leakage has little effect at early times. The comparison between the results of this study and that of Hantush and Jacob (1955) indicates that the dimensionless drawdown in the aquifer for non-Darcian flow is larger at early times and smaller at late times, than their counterparts for Darcian flow. A larger dimensionless non-Darcian conductivity kD results in a smaller dimensionless drawdown in the aquifer at late times, and leads to a larger dimensionless drawdown in the aquifer at early times. A smaller dimensionless leakage parameter BD results in a smaller drawdown at late times, and the leakage does not affect the early-time drawdown. The analysis of the dimensionless drawdown inside the well has also been included in this study when the wellbore storage is considered.  相似文献   

2.
We have investigated non‐Darcian flow to a vertical fracture represented as an extended well using a linearization procedure and a finite difference method in this study. Approximate analytical solutions have been obtained with and without the consideration of fracture storage based on the linearization procedure. A numerical solution for such a non‐Darcian flow case has also been obtained with a finite difference method. We have compared the numerical solution with the approximate analytical solutions obtained by the linearization method and the Boltzmann transform. The results indicate that the linearized solution agrees generally well with the numerical solution at late times, and underestimates the dimensionless drawdown at early times, no matter if the fracture storage is considered or not. When the fracture storage is excluded, the Boltzmann transform solution overestimates the dimensionless drawdown during the entire pumping period. The dimensionless drawdowns in the fracture with fracture storage for different values of dimensionless non‐Darcian hydraulic conductivity β approach the same asymptotic value at early times. A larger β value results in a smaller dimensionless drawdown in both the fracture and the aquifer when the fracture storage is included. The dimensionless drawdown is approximately proportional to the square root of the dimensionless time at late times.  相似文献   

3.
We have developed a new method to analyze the power law based non-Darcian flow toward a well in a confined aquifer with and without wellbore storage. This method is based on a combination of the linearization approximation of the non-Darcian flow equation and the Laplace transform. Analytical solutions of steady-state and late time drawdowns are obtained. Semi-analytical solutions of the drawdowns at any distance and time are computed by using the Stehfest numerical inverse Laplace transform. The results of this study agree perfectly with previous Theis solution for an infinitesimal well and with the Papadopulos and Cooper’s solution for a finite-diameter well under the special case of Darcian flow. The Boltzmann transform, which is commonly employed for solving non-Darcian flow problems before, is problematic for studying radial non-Darcian flow. Comparison of drawdowns obtained by our proposed method and the Boltzmann transform method suggests that the Boltzmann transform method differs from the linearization method at early and moderate times, and it yields similar results as the linearization method at late times. If the power index n and the quasi hydraulic conductivity k get larger, drawdowns at late times will become less, regardless of the wellbore storage. When n is larger, flow approaches steady state earlier. The drawdown at steady state is approximately proportional to r1−n, where r is the radial distance from the pumping well. The late time drawdown is a superposition of the steady-state solution and a negative time-dependent term that is proportional to t(1−n)/(3−n), where t is the time.  相似文献   

4.
This paper derives an equivalent of Darcian Theis solution for non-Darcian flow induced by constant rate pumping of a well in a confined aquifer. The derivation, which is valid at later times only, is original. It utilizes Izbash's equation. This introduces an additional parameter to Darcian condition, namely, empirical exponent. The solution is a non-Drcian equivalent of Jacob straight line method for analyzing pumping tests at late times. It can be used to determine aquifer parameters: storativity, analogous hydraulic conductivity, and empirical exponent. However, while the Jacob method requires a minimum of only one pumping test with one observation well, the additional parameter in the present solution means that a minimum of two observation wells in one test or two pumping tests at different rates with one observation well are required. The derived solution is applied to a case study at Plomeur in Brittany, France, and is shown to provide a practical and efficient method for analyzing pumping tests where non-Darcian groundwater flow occurs.  相似文献   

5.
Evaluation of the MODFLOW-2005 Conduit Flow Process   总被引:1,自引:0,他引:1  
The recent development of the Conduit Flow Process (CFP) by the U.S. Geological Survey (USGS) provides hydrogeologic modelers with a new tool that incorporates the non-Darcian, multiporosity components of flow characteristic of karst aquifers. CFP introduces new parameters extending beyond those of traditional Darcian groundwater flow codes. We characterize a karst aquifer to collect data useful for evaluating this new tool at a test site in west-central Florida, where the spatial distribution and cross-sectional area of the conduit network are available. Specifically, we characterize: (1) the potential for Darcian/non-Darcian flow using estimates of specific discharge vs. observed hydraulic gradients, and (2) the temporal variation for the direction and magnitude of fluid exchange between the matrix and conduit network during extreme hydrologic events. We evaluate the performance of CFP Mode 1 using a site-scale dual-porosity model and compare its performance with a comparable laminar equivalent continuum model (ECM) using MODFLOW-2005. Based on our preliminary analyses, hydraulic conductivity coupled with conduit wall conductance improved the match between observed and simulated discharges by 12% to 40% over turbulent flow alone (less than 1%).  相似文献   

6.
Non-Darcian flow towards a well which fully penetrates a confined single vertical fracture is presented in this paper on the basis of the Izbash equation. We have obtained semi-analytical solutions for non-Darcian flow by using the Boltzmann transform and developed the non-Darcian flow well functions for cases with and without the effect of wellbore storage. The results show that the non-Darcian flow type curves are more or less deviated from the Darcian flow type curve. The non-linear effect is mainly attributable to the turbulent factor, v, a dimensionless parameter related to the pumping rate, the fracture aperture, the fracture thickness, and two constants k′ and n used in the Izbash power-law. The non-linear effect appears to be less sensitive to the power-law index, n. When excluding wellbore storage, the well function at early times is proportional to v−1/(n−1)un/(n−1), where u is a dimensionless term inversely proportional to time; whereas the well function at late times is approximated as , where A0(n) is a finite term depending on n. When considering wellbore storage, drawdowns inside the well with different v values approach the same asymptotic value at small times, and the effect of wellbore storage is only found at the early stage of pumping.  相似文献   

7.
The acceptability of the hypothesis of Darcian flow through a semiconfined carbonate aquifer was tested prior to running a multiple-day aquifer test in Pinellas County, Florida. The approach used to test the hypothesis was to run a number of hour-long aquifer tests at different discharges with drawdown measured at the same time during each test in two observation wells, one at 35 feet and the other at 733 feet from the pumped well. If the hypothesis were acceptable, a plot of drawdown versus discharge should describe a straight line. A linear relation was described in 15-minute and 1-hour data plots of drawdown versus discharge for both observation wells. Thus, the hypothesis of Darcian flow through the semiconfined carbonate aquifer was deemed acceptable. Drawdown data from the distant observation well collected during the following multiple-day aquifer test were then analyzed for aquifer-property values of transmissivity, storage coefficient, and leakance coefficient using standard methods. Discharge for the multiple-day test was within the discharge range of the hour-long tests.  相似文献   

8.
Abstract

A simplified method has been developed for solving leaky aquifer non-Darcian flow hydraulics. The principle of volumetric approach is combined with the confined-aquifer, time-dependent drawdown equation in an observation well. The groundwater flow in the leaky aquifer is assumed to obey a non-Darcian flow law of exponential type. The results are obtained in the form of type-curve expressions from which the necessary bundles of curves are drawn for a set of selective non-Darcian flow aquifer parameters. Although application of the methodology appears as rather limited but it provides a scientific contribution and extension of leaky aquifer theory towards nonlinear flow conditions. The methodology developed herein is applied to some actual field data from the eastern sedimentary basin in the Kingdom of Saudi Arabia.  相似文献   

9.
This study presents analytical solutions of the three‐dimensional groundwater flow to a well in leaky confined and leaky water table wedge‐shaped aquifers. Leaky wedge‐shaped aquifers with and without storage in the aquitard are considered, and both transient and steady‐state drawdown solutions are derived. Unlike the previous solutions of the wedge‐shaped aquifers, the leakages from aquitard are considered in these solutions and unlike similar previous work for leaky aquifers, leakage from aquitards and from the water table are treated as the lower and upper boundary conditions. A special form of finite Fourier transforms is used to transform the z‐coordinate in deriving the solutions. The leakage induced by a partially penetrating pumping well in a wedge‐shaped aquifer depends on aquitard hydraulic parameters, the wedge‐shaped aquifer parameters, as well as the pumping well parameters. We calculate lateral boundary dimensionless flux at a representative line and investigate its sensitivity to the aquitard hydraulic parameters. We also investigate the effects of wedge angle, partial penetration, screen location and piezometer location on the steady‐state dimensionless drawdown for different leakage parameters. Results of our study are presented in the form of dimensionless flux‐dimensionless time and dimensionless drawdown‐leakage parameter type curves. The results are useful for evaluating the relative role of lateral wedge boundaries and leakage source on flow in wedge‐shaped aquifers. This is very useful for water management problems and for assessing groundwater pollution. The presented analytical solutions can also be used in parameter identification and in calculating stream depletion rate and volume. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

10.
Actual pumping tests may involve continuously decreasing rates over a certain period of time, and the hydraulic conductivity (K) and specific storage (Ss) of the tested confined aquifer cannot be interpreted from the classical constant‐rate test model. In this study, we revisit the aquifer drawdown characteristics of a pumping test with an exponentially decreasing rate using the dimensionless analytical solution for such a variable‐rate model. The drawdown may decrease with time for a short period of time at intermediate pumping times for such pumping tests. A larger ratio of initial to final pumping rate and a smaller radial distance of the observation well will enhance the decreasing feature. A larger decay constant results in an earlier decrease, but it weakens the extent of such a decrease. Based on the proposed dimensionless transformation, we have proposed two graphical methods for estimating K and Ss of the tested aquifer. The first is a new type curve method that does not employ the well function as commonly done in standard type curve analysis. Another is a new analytic method that takes advantage of the decreasing features of aquifer drawdown during the intermediate pumping stage. We have demonstrated the applicability and robustness of the two new graphical methods for aquifer characterization through a synthetic pumping test.  相似文献   

11.
An analytical model is presented for the analysis of constant flux tests conducted in a phreatic aquifer having a partially penetrating well with a finite thickness skin. The solution is derived in the Laplace transform domain for the drawdown in the pumping well, skin and formation regions. The time-domain solution in terms of the aquifer drawdown is then obtained from the numerical inversion of the Laplace transform and presented as dimensionless drawdown–time curves. The derived solution is used to investigate the effects of the hydraulic conductivity contrast between the skin and formation, in addition to wellbore storage, skin thickness, delayed yield, partial penetration and distance to the observation well. The results of the developed solution were compared with those from an existing solution for the case of an infinitesimally thin skin. The latter solution can never approximate that for the developed finite skin. Dimensionless drawdown–time curves were compared with the other published results for a confined aquifer. Positive skin effects are reflected in the early time and disappear in the intermediate and late time aquifer responses. But in the case of negative skin this is reversed and the negative skin also tends to disguise the wellbore storage effect. A thick negative skin lowers the overall drawdown in the aquifer and leads to more persistent delayed drainage. Partial penetration increases the drawdown in the case of a positive skin; however its effect is masked by the negative skin. The influence of a negative skin is pronounced over a broad range of radial distances. At distant observation points the influence of a positive skin is too small to be reflected in early and intermediate time pumping test data and consequently the type curve takes its asymptotic form.  相似文献   

12.
A. Altunkaynak  Z. Şen 《水文研究》2011,25(11):1778-1783
Darcian flow law in aquifers assumes that the aquifer hydraulic conductivity is constant and the groundwater movement is due only to the piezometric level changes through hydraulic gradient. In practice, after the well development the aquifer just around the well has comparatively larger hydraulic conductivity and gradient. Patchy aquifer solutions in the literature consider sudden hydraulic conductivity changes with distance for the steady state flow. The change of transmissivity is demonstrated by the application of slope‐matching procedure to actual field data. It is the main purpose of this paper to derive simple analytical expressions for aquifer parameter evaluations with steadily decreasing hydraulic conductivity around the well. Spatial nonlinear hydraulic conductivity changes around a large‐diameter well within the depression cone of a confined aquifer are considered as exponentially decreasing functions of the radial distance. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

13.
Wells in aquifers of loose collapsible sediment are cased so that they have a blind wall and gain water only from the bottom. The hydraulic gradient established at the bottom of these wells during pumping brings the aquifer materials in a quicksand state, which may cause abrasion of pipes and pumps and even the destruction of well structure. To examine the quicksand occurrence, an analytical solution for the steady flow to a partially penetrating blind‐wall well in a confined aquifer is developed. The validity of the proposed solution is evaluated numerically. The sensitivity of maximum vertical gradient along the well bottom in response to aquifer and well parameters is examined. The solution is presented in the form of dimensionless‐type curves and equations that can be easily used to design the safe pumping rate and optimum well geometry to protect the well against sand production. The solution incorporates the anisotropy of aquifer materials and can also be used to determine the hydraulic conductivity of the aquifer. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

14.
Faults can act as flow barriers or conduits to groundwater flow by introducing heterogeneity in permeability. We examine the hydrogeology of the Sandwich Fault Zone, a 137 km long zone of high-angle faults in northern Illinois, using a large-scale historic aquifer test. The fault zone is poorly understood at depth due to the majority of the faults being buried by glacial deposits and its near-vertical orientation which limits geologic sampling across faults. The aquifer test—perhaps one of the largest in terms of overall withdrawal in North American history—was conducted in 1942 at a facility adjacent to the fault zone. More than 34,000 m3/day was pumped for 37 days from nine multiaquifer wells open to the stratified Cambrian-Ordovician sandstone aquifer system. We modeled the aquifer test using a transient MODFLOW-USG model and simulated pumping wells with the CLN package. We tested numerous fault core/damage zone conceptualizations and calibrated to drawdown values recorded at production and observation wells. Our analysis indicates that the fault zone is a low-permeability feature that inhibits lateral movement of groundwater and that there is at least an order of magnitude decrease in horizontal hydraulic conductivity in the fault core compared to the undeformed sandstone. Large head declines have occurred north of the fault zone (over 300 m since predevelopment conditions) and modifying fault zone parameters significantly affects calibration to regional drawdown on a decadal scale. The flow-barrier behavior of the fault zone has important implications for future groundwater availability in this highly stressed region.  相似文献   

15.
A new type of vertical circulation well (VCW) is used for groundwater dewatering at construction sites. This type of VCW consists of an abstraction screen in the upper part and an injection screen in the lower part of a borehole, whereby drawdown is achieved without net withdrawal of groundwater from the aquifer. The objective of this study is to evaluate the operation of such wells including the identification of relevant factors and parameters based on field data of a test site and comprehensive numerical simulations. The numerical model is able to delineate the drawdown of groundwater table, defined as free‐surface, by coupling the arbitrary Lagrangian–Eulerian algorithm with the groundwater flow equation. Model validation is achieved by comparing the field observations with the model results. Eventually, the influences of selected well operation and aquifer parameters on drawdown and on the groundwater flow field are investigated by means of parameter sensitivity analysis. The results show that the drawdown is proportional to the flow rate, inversely proportional to the aquifer conductivity, and almost independent of the aquifer anisotropy in the direct vicinity of the well. The position of the abstraction screen has a stronger effect on drawdown than the position of the injection screen. The streamline pattern depends strongly on the separation length of the screens and on the aquifer anisotropy, but not on the flow rate and the horizontal hydraulic conductivity.  相似文献   

16.
Data from a large-scale canal-drawdown test were used to estimate the specific yield (sy) of the Biscayne Aquifer, an unconfined limestone aquifer in southeast Florida. The drawdown test involved dropping the water level in a canal by about 30 cm and monitoring the response of hydraulic head in the surrounding aquifer. Specific yield was determined by analyzing data from the unsteady portion of the drawdown test using an analytical stream-aquifer interaction model (Zlotnik and Huang 1999). Specific yield values computed from drawdown at individual piezometers ranged from 0.050 to 0.57, most likely indicating heterogeneity of specific yield within the aquifer (small-scale variation in hydraulic conductivity may also have contributed to the differences in sy among piezometers). A value of 0.15 (our best estimate) was computed based on all drawdown data from all piezometers. We incorporated our best estimate of specific yield into a large-scale two-dimensional numerical MODFLOW-based ground water flow model and made predictions of head during a 183-day period at four wells located 337 to 2546 m from the canal. We found good agreement between observed and predicted heads, indicating our estimate of specific yield is representative of the large portion of the Biscayne Aquifer studied here. This work represents a practical and novel approach to the determination of a key hydrogeological parameter (the storage parameter needed for simulation and calculation of transient unconfined ground water flow), at a large spatial scale (a common scale for water resource modeling), for a highly transmissive limestone aquifer (in which execution of a traditional pump test would be impractical and would likely yield ambiguous results). Accurate estimates of specific yield and other hydrogeological parameters are critical for management of water supply, Everglades environmental restoration, flood control, and other issues related to the ground water hydrology of the Biscayne Aquifer.  相似文献   

17.
The Laplace domain solutions have been obtained for three-dimensional groundwater flow to a well in confined and unconfined wedge-shaped aquifers. The solutions take into account partial penetration effects, instantaneous drainage or delayed yield, vertical anisotropy and the water table boundary condition. As a basis, the Laplace domain solutions for drawdown created by a point source in uniform, anisotropic confined and unconfined wedge-shaped aquifers are first derived. Then, by the principle of superposition the point source solutions are extended to the cases of partially and fully penetrating wells. Unlike the previous solution for the confined aquifer that contains improper integrals arising from the Hankel transform [Yeh HD, Chang YC. New analytical solutions for groundwater flow in wedge-shaped aquifers with various topographic boundary conditions. Adv Water Resour 2006;26:471–80], numerical evaluation of our solution is relatively easy using well known numerical Laplace inversion methods. The effects of wedge angle, pumping well location and observation point location on drawdown and the effects of partial penetration, screen location and delay index on the wedge boundary hydraulic gradient in unconfined aquifers have also been investigated. The results are presented in the form of dimensionless drawdown-time and boundary gradient-time type curves. The curves are useful for parameter identification, calculation of stream depletion rates and the assessment of water budgets in river basins.  相似文献   

18.
Alluvial fans are potential sites of potable groundwater in many parts of the world. Characteristics of alluvial fans sediments are changed radially from high energy coarse-grained deposition near the apex to low energy fine-grained deposition downstream so that patchy wedge-shaped aquifers with radial heterogeneity are formed. The hydraulic parameters of the aquifers (e.g. hydraulic conductivity and specific storage) change in the same fashion. Analytical or semi-analytical solutions of the flow in wedge-shaped aquifers are available for homogeneous cases. In this paper we derive semi-analytical solutions of groundwater flow to a well in multi-zone wedge-shaped aquifers. Solutions are provided for three wedge boundary configurations namely: constant head–constant head wedge, constant head–barrier wedge and barrier–barrier wedge. Derivation involves the use of integral transforms methods. The effect of heterogeneity ratios of zones on the response of the aquifer is examined. The results are presented in form of drawdown and drawdown derivative type curves. Heterogeneity has a significant effect on over all response of the pumped aquifer. Solutions help understanding the behavior of heterogeneous multi-zone aquifers for sustainable development of the groundwater resources in alluvial fans.  相似文献   

19.
Pumping test evaluation of stream depletion parameters   总被引:1,自引:0,他引:1  
Lough HK  Hunt B 《Ground water》2006,44(4):540-546
  相似文献   

20.
An Analysis of Low-Flow Ground Water Sampling Methodology   总被引:1,自引:0,他引:1  
Low-flow ground water sampling methodology can minimize well disturbance and aggravated colloid transport into samples obtained from monitoring wells. However, in low hydraulic conductivity formations, low-flow sampling methodology can cause excessive drawdown that can result in screen desaturation and high ground water velocities in the vicinity of the well, causing unwanted colloid and soil transport into ground water samples taken from the well. Ground water velocities may increase several fold above that of the natural setting. To examine the drawdown behavior of a monitoring well, mathematical relationships can be developed that allow prediction of the steady-state drawdown for constant low-flow pumping rates based on well geometry and aquifer properties. The equations also estimate the time necessary to reach drawdown equilibrium. These same equations can be used to estimate the relative contribution of water entering a sampling device from either the well standpipe or the aquifer. Such equations can be useful in planning a low-flow sampling program and may suggest when to collect a water sample. In low hydraulic conductivity formations, the equations suggest that drawdown may not stabilize for well depths, violating the minimal drawdown requirement of the low-flow technique. In such cases, it may be more appropriate to collect a slug or passive sample from the well screen, under the assumption that the water in the well screen is in equilibrium with the surrounding aquifer.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏