首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Pretreatment of waste emulsions with high organic content by a combined process of vibratory shear enhanced process and Fenton’s oxidation prior to biological treatment was investigated. Vibrating membrane had shown good performance in chemical oxygen demand and oil removals and the mitigation of concentration polarization. However, the permeate after filtration processing still contained high content of organics. Thus, additional Fenton oxidation was applied to reduce the organic loading, and improve the biodegradability of the wastewater. The optimal molar ratio of ferrous iron to hydrogen peroxide was 0.05 obtained from the jar-test experiments. Removal of organics was enhanced by increasing hydrogen peroxide dosage, while efficiency of hydrogen peroxide reached maximum of 1.11(w/w) at the hydrogen peroxide dosage of 6.8 g/L. Furthermore, the biological experiments indicated that the high concentration of organics could inhibit microbial activity, which decreased the chemical oxygen demand degradation rates. The adaptive period of the microbe was greatly shortened using Fenton’s reagent at the low dosages. The improvement of the biodegradability could be explained by partial mineralization and chemical transformation of parent organic compounds after Fenton oxidation.  相似文献   

2.
A large portion of water is consumed during various textile operations thereby discharging wastewaters with pollutants of huge environmental concern. The treatment of such wastewaters has promising impact in the field of environmental engineering. In this work, Fenton oxidation treatment was engaged to treat simulated textile wastewater. Box–Behnken design and response surface methodology were employed to optimize the efficiency of Fenton process. Iron dose, peroxide dose and pH were considered as input variables while the responses were taken as chemical oxygen demand and color removal. A total of 17 experiments were conducted and analyzed using second-order quadratic model. The quadratic models generated for chemical oxygen demand and color removal efficiencies were validated using analysis of variances, and it was found that the experimental data fitted the second-order model quite effectively. Analysis of variances demonstrated high values of coefficient of determination (R 2) for chemical oxygen demand and color removal efficiencies with values of 0.9904 and 0.9963 showing high conformation of predicted values to the experimental ones. Perturbation plots suggested that the iron dosage produced the maximum effect on both chemical oxygen demand and color removal efficiencies. The optimum parameters were determined as Fe2+ dose—550 mg/L, H2O2 dose—5538 mg/L, pH—3.3 with corresponding chemical oxygen demand and color removal efficiencies of 73.86 and 81.35%. Fenton process was found efficient in treatment of simulated textile wastewater, and optimization using response surface methodology was found satisfactory as well as relevant. From the present study, it can also be concluded that if this method is used as pretreatment integrated with biological treatment, it can lead to eco-friendly solution for treatment of textile wastewaters.  相似文献   

3.
Ultraviolet photolysis and ultraviolet and hydrogen peroxide oxidation of fourteen commonly used pharmaceutical compounds and two personal care products in mixed solution using low pressure ultraviolet lamp was investigated in laboratory batch experiments. Removal of the compounds followed the first-order reaction kinetic. Three distinct impacts of hydrogen peroxide on ultraviolet and hydrogen peroxide oxidation of the compounds (positive, negative and no significant effect) were observed. Removal behavior of the several tested compounds in mixed solution varied significantly than their respective behavior in absence of coexisting compounds. Clofibric acid, diclofenac, fenoprofen, isopropylantipyrine, ketoprofen, phenytoin and triclosan were removed very efficiently (> 96 %) by ultraviolet photolysis alone. Residual hydrogen peroxide during ultraviolet and hydrogen peroxide oxidation was quantitated for the first time. Hydrogen peroxide addition to ultraviolet photolysis was not worthy for majority of the tested compounds as their removal did not increase significantly and very big fractions (> 85 %) of the added hydrogen peroxide (0.29 ~ 1.47 mM) remained unused presumably due to small fluence of the lamp, very small molar absorption for hydrogen peroxide at 254 nm (27.06 /M.cm) and acidic pH of reaction solution (< 5.7). Further exploration on ultraviolet and hydrogen peroxide oxidation with higher fluence lamp and alkaline solution pH will clarify usefulness of the method to treat pharmaceutical contaminated waters.  相似文献   

4.
The objective of this study was to explore the extent of 2,4,6-trinitrotoluene synthetic solution and red water mineralization by comparing conventional direct ozonation and multi-stage ozonation-biological treatment process. The alkaline hydrolysis was used for remediation 2, 4, 6-trinitrotoluene and red water at pH = 10.9. Nevertheless, the hydroxyl radicals would be generated by ozone decomposition with ozone dose of 0.177 g/L. The samples were subjected to chemical oxygen demand and total organic carbon analysis to monitor pollutants removal. The rate of 2, 4, 6-trinitrotoluene and red water pollutants degradation were quantified using high performance liquid chromatography. 2, 4, 6-trinitrotoluene synthetic solution resulted 55.5 % chemical oxygen demand removal by 3 h direct ozonation. Following direct ozonation the biological treatment twenty four hours chemical oxygen demand reached 98.9 % and 98.7 % removal using humic acid and river water 1 % ( v/v) inoculation singly and respectively. Conventional direct ozonation showed non significant change in total organic carbon degradation. While on using multi-stage ozone-biological treatment process where humic acid and/or river water were used as inoculums singly and respectively, total organic carbon fulfilled 73 % and 98.3 % removal. The process was one hour direct ozonation and followed by three days multi-stage ozone-biological treatment. In multi-stage ozone-biological treatment process, ozonation was effective to decompose total organic carbon and to produce biodegradable dissolved organic carbon easily removed by ozone oxidation up to 98.3 % in 2,4,6-trinitrotoluene synthetic solution. Pollutants removal achieved 99 % in authentic red water effluent using river inoculation 1 % (v/v) in 5 days. Nuclear Magnetic Resonance and Fourier Transformation Infra Red methods were performed to confirm types of pollutants content in red water.  相似文献   

5.
This paper reports the results of the treatment of a yarn dyeing effluent using an integrated biological–chemical oxidation process. In particular, the biological unit was based on a sequencing batch biofilter granular sludge reactor (SBBGR), while the chemical treatment consisted of an ozonation step. Biological treatment alone was first performed as a reference for comparison. While biological treatment did not produce an effluent for direct discharge, the integrated process assured good treatment results, with satisfactory removal of chemical oxygen demand (up to 89.8 %), total nitrogen (up to 88.2 %), surfactants (up to 90.7 %) and colour (up to 99 %), with an ozone dose of 110 mg of ozone per litre of wastewater. Biomass characterization by fluorescence in situ hybridization has revealed that filamentous bacteria represented about 20 % of biomass (coherently with high sludge volume index values); thanks to its special design, SBBGR guaranteed, however, stable treatment performances and low effluent suspended solids concentrations, while conventional activated sludge systems suffer from sludge bulking and even treatment failure in such a condition. Furthermore, biomass characterization has evidenced the presence of a shortcut nitrification–denitrification process.  相似文献   

6.
This review carries out a comparative study of advanced technologies to design, upgrade and rehabilitate wastewater treatment plants. The study analyzed the relevant researches in the last years about the moving bed biofilm reactor process with only attached biomass and with hybrid biomass, which combined attached and suspended growth; both could be coupled with a secondary settling tank or microfiltration/ultrafiltration membrane as a separation system. The physical process of membrane separation improved the organic matter and NH4 +-N removal efficiencies compared with the settling tank. In particular, the pure moving bed biofilm reactor–membrane bioreactor showed average chemical oxygen demand, biochemical oxygen demand on the fifth day and total nitrogen removal efficiencies of 88.32, 90.84 and 60.17%, respectively, and the hybrid moving bed biofilm reactor–membrane bioreactor had mean chemical oxygen demand, biochemical oxygen demand on the fifth day and total nitrogen reduction percentages of 91.18, 97.34 and 68.71%, respectively. Moreover, the hybrid moving bed biofilm reactor–membrane bioreactor showed the best efficiency regarding organic matter removal for low hydraulic retention times, so this system would enable the rehabilitation of activated sludge plants and membrane bioreactors that did not comply with legislation regarding organic matter removal. As the pure moving bed biofilm reactor–membrane bioreactor performed better than the hybrid moving bed biofilm reactor–membrane bioreactor concerning the total nitrogen removal under low hydraulic retention times, this system could be used to adapt wastewater treatment plants whose effluent was flowed into sensitive zones where total nitrogen concentration was restricted. This technology has been reliably used to upgrade overloaded existing conventional activated sludge plants, to treat wastewater coming from textile, petrochemical, pharmaceutical, paper mill or hospital effluents, to treat wastewater containing recalcitrant compounds efficiently, and to treat wastewater with high salinity and/or low and high temperatures.  相似文献   

7.
Removal of Congo red from textile wastewater by ozonation   总被引:7,自引:6,他引:1  
Congo red, which has a complex molecular structure with various diazo aromatic groups, is widely used in textile industry as an anionic dye. The purpose of this study was to investigate the degradation of Congo red in laboratory solution which had the chemical properties of the rinse waters of textile manufacturing dye-houses and the samples with Congo red alone wastewater by ozonation and to optimize the reaction parameters such as pH and time which influence the efficiencies of total organic carbon, total kjeldahl nitrogen and chemical oxygen demand removal. Ozonation of Congo red dye were carried out in a semi-batch reactor with constant ozone flow rate and concentration of 23 mL/sec and 13.6 mg/L, respectively. Decolorization was complete within a few minutes of ozonation possibly due to the cleavage of chromophore groups. It was observed that its structural destruction occurs predominantly at higher pHs. The reduction of chemical oxygen demand and destruction of the dye was more than 60 % and 42 %, respectively. Total kjeldahl nitrogen removal was accompanied by slight changes in nitrogen oxides. It can be deduced from the experimental results that: (a) the mineralization is very weak; (b) the reaction follows the indirect mechanism; i.e., the interaction of hydroxyl radicals with the dye and (c) the nitrification is rather predominant. Biological oxygen demand is declined in simulated alkalic and neutral samples respectively. At 13.6 mg O3/L, the biological oxygen demand levels were significantly enhanced. This might be attributable to the enhancement of its biodegradation at alkaline pHs.  相似文献   

8.
Hydrogen peroxide and hydroxyl radical are readily formed during the oxidation of pyrite with molecular oxygen over a wide range of pH conditions. However, pretreatment of the pyrite surface influences how much of the intermediates are formed and their fate. Acid-washed pyrite produces significant amounts of hydrogen peroxide and hydroxyl radical when suspended in air-saturated water. However, the hydrogen peroxide concentration shows an exponential decrease with time. Suspensions made with partially oxidized pyrite yield significantly lower amounts of hydrogen peroxide product. The presence of Fe(III)-oxide or Fe(III)-hydroxide patches facilitates the conversion of hydrogen peroxide to oxygen and water. Hence, the degree to which a pyrite surface is covered with patches of Fe(III)-oxide or Fe(III)-hydroxide patches is an important control on the concentration of hydrogen peroxide in solution.Hydrogen peroxide appears to be an important intermediate in the four-electron transfer from pyrite to molecular oxygen. Addition of catalase, an enzyme that decomposes hydrogen peroxide to water and molecular oxygen, to a pyrite suspension reduces the oxidation rate by 40%. By contrast, hydroxyl radical does not appear to play a significant role in the oxidation mechanism. It is estimated on the basis of a molecular oxygen and sulfate mass balance that 5-6% of the molecular oxygen is consumed without forming sulfate.  相似文献   

9.
High-concentrated sulfur wastewater with sodium and COD (chemical oxygen demand) up to 26000 mg/L from a chemical plant, Jiangsu Province of China has been treated by deposition of natrojarosite in lab. The results indicated that the COD of the wastewater was decreased sharply from 26000 mg/L to 1001 mg/L, with removal rate of COD up to 96% by twice precipitations of natrojarosite and twice oxidation of H202. The treated sulfur wastewater reached the requirement of subsequent biochemical treatment to water quality. The optimal operational parameters should be controlled on pH value between 2.50 and 3.20 and 50 g FeCly6H2O solid added in per liter wastewater. The study provided an experimental basis for pretreatment of high-concentrated sulfur wastewater and proposed a new mineralogical method on treatment of other wastewaters. Depositing process of jarosite and its analogs should be able to be used to treat wastewater from mine and other industries to remove S, Fe and other toxic and harmful elements, such as As, Cr, Hg, Pb, etc. in the water.  相似文献   

10.
In the present study, the effectiveness of physicochemical treatment processes (coagulation and Fenton’s oxidation) was investigated for simulated dairy wastewater (pH = 7.3, chemical oxygen demand (COD) = 3600 mg/l, 5-day biochemical oxygen demand (BOD5) = 1950 mg/l, total Kjeldahl nitrogen (TKN) = 87 mg/l, and total phosphorous (TP) = 14 mg/l). Plain and ballasted coagulation runs were carried out in a jar apparatus, while Fenton’s oxidation was performed in a three-neck glass reactor. Ballasted coagulation caused an enhancement in the settling rate of sludge though no significant enhancement in the removal of organics was observed. Individually, coagulation and Fenton’s oxidation processes resulted in ~67 and 80 % COD removals, respectively, from the wastewater. The sequential treatment exploring coagulation followed by Fenton’s oxidation showed overall COD, BOD5, TKN, and TP reductions of ~93, 97, 84, and 70 %, respectively, from the wastewater. However, a biological post-treatment would be required to achieve the effluent discharge standards. The removal of proteins, fats, and amino acids from wastewater was confirmed from Fourier transform infrared analysis of the settled sludge (obtained after coagulation process). Preliminary cost analysis suggested coagulation and the sequential treatment (i.e. coagulation followed by Fenton’s oxidation) as the preferred options.  相似文献   

11.
This study was conducted to evaluate the chemical parameters and the cytotoxic and genotoxic potential of raw domestic sewage and effluents from treatment with activated sludge and a floating emergent-macrophyte filter from a domestic wastewater treatment plant in the city of Novo Hamburgo, Rio Grande do Sul, Brazil. The physicochemical analysis revealed that both treatment systems achieved the legal emission pattern for biochemical oxygen demand, chemical oxygen demand, and suspended solids, but ammoniacal nitrogen and E. coli values were above the limits in the macrophyte treatment effluent. Phosphorous values were above the maximum permitted for both treatments. The results obtained from the Allium cepa test and the micronuclei test in fish did not demonstrate any significant differences in both cytotoxicity (mitotic index) and genotoxicity (chromosome aberration and micronucleus) endpoints between the negative control group and the exposed groups. However, the comet assay in fish revealed a DNA damage increase in animals exposed to the 30 % concentration of the macrophyte effluent and two concentrations of the activated sludge treatment effluent (10 and 75 %), which suggests that these two treatment systems may increase wastewater genotoxicity.  相似文献   

12.
In recent years, concerns about the occurrence and fate of active pharmaceutical ingredients, solvents, intermediates and raw materials that could be present in pharmaceutical industry effluents have gained increasing attention. Conventional treatment methods, such as activated sludge, are not sufficient enough to remove active pharmaceutical ingredients completely. As a result, complementary treatment methods like coagulation and flocculation are often used and play a critical role in industrial and municipal wastewater treatment. The primary goal of these methods is to destabilize and remove colloidal particles along with other organic/inorganic contaminants. Recently empirical works have considered ozone as the most promising oxidant for the removal of micro-pollutants. The current study examined the effectiveness of coagulation/flocculation process using ferric chloride, polyaluminum chloride, and aluminum sulfate as a reasonable approach to tackle the issue of treating pharmaceutical wastewater. In addition, the results were compared with the process using only ferric chloride that was the coagulant of an actual treatment plant. Then, improvement of the process performance was investigated using ozone as an oxidant. In conclusion, it was found out that polyaluminum chloride presented better performance among two other coagulants and also adding 200 mg/L of polyaluminum chloride can lead to 97–98 % turbidity removal efficiency. Moreover, polyaluminum chloride was capable of reducing most of the environmental parameters such as chemical oxygen demand and total dissolved solid with the removal efficiency of 70 and 68 %, respectively. Additionally, ozonation improved the coagulation process, especially iron ion removal, and dramatically decreased the concentration from 5.68 to 0.19 mg/L.  相似文献   

13.
Sources of oxygen demand in the lower San Joaquin River,California   总被引:1,自引:0,他引:1  
Dissolved oxygen concentration below 5 mg 1−1 has characterized the lower tidal portion of the San Joaquin River downstream of Stockton, California, during the summer and fall for the past four decades. Intensive field research in 2000 and 2001 indicated low dissolved oxygen concentration was restricted to the first 14 km of the river, which was deepened to 12 m for shipping, downstream of Stockton. The persistent low dissolved oxygen concentration in the shipping channel was not caused by physical stratification that prevented aeration from vertical mixing or respiration associated wigh high phytoplankton biomass. The low dissolved oxygen concentration was primarily caused bynitrification that produced up to 81% of the total oxygen demand. Stepwise multiple regression analysis isolated dissolved ammonia concentration and carbonaceous oxygen demand as the water quality variables most closely associated with the variation in oxygen demand. Between these two sources, dissolved ammonia concentration accounted for 60% of the total variation in oxygen demand compared with a maximum of 30% for carbonceous oxygen demand. The Stockton wastewater treatment plant and nonpoint sources upstream were direct sources of dissolved ammonia in the channel. A large portion of the dissolved ammonia in the channel was also produced by oxidation of the organic nitrogen load from upstream. The phytoplankton biomass load from upstream primarily produced the carbonaceous oxygen demand. Mass balance models suggested the relative contribution of the wastewater and nonpoint upstream load to the ammonia concentration in the shipping channel at various residence times was dependent on the cumulative effect of ammonification, composition of the upstream load, and net downstream transport of the daily load.  相似文献   

14.
The upflow anaerobic sludge blanket process followed by the biological aerated filter process was employed to improve the removal of color and recalcitrant compounds from real dyeing wastewater. The highest removal efficiency for color was observed in the anaerobic process, at 8-h hydraulic retention time, seeded with the sludge granule. In the subsequent aerobic process packed with the microbe-immobilized polyethylene glycol media, the removal efficiency for chemical oxygen demand increased significantly to 75 %, regardless of the empty bed contact time. The average influent non-biodegradable soluble chemical oxygen demand was 517 mg/L, and the average concentration in effluent from the anaerobic reactor was 363 mg/L, suggesting the removal of some recalcitrant matters together with the degradable ones. The average non-biodegradable soluble chemical oxygen demand in effluent from the aerobic reactor was 87, 93, and 118 mg/L, with the removal efficiency of 76, 74, and 67 %, at 24-, 12-, and 8-h empty bed contact time, respectively. The combined anaerobic sludge blanket and aerobic cell-entrapped process was effective to remove the refractory compounds from real dyeing wastewater as well as in reducing organic loading to meet the effluent discharge limits. This integrated process is considered an effective and economical treatment technology for dyeing wastewater.  相似文献   

15.
In this study, the treatability of marble processing wastewater by electrocoagulation using aluminum and iron electrodes was investigated. The sample used was from the marble-processing plant in Sivas and its turbidity, suspended solids, chemical oxygen demand and total solids concentrations were about 1,914?NTU, 2,904, 150 and 4,750?mg/L, respectively. The effects of various operating parameters such as initial pH, current density and electrolysis time on turbidity, suspended solids, chemical oxygen demand and total solids removal efficiencies were investigated. The settling characteristics of waste sludge produced and energy and electrode consumption were also determined. The optimum values of initial pH, current density and electrolysis time in electrocoagulation studies carried out using aluminum electrode were found to be 7.8, 30?A/m2 and 5?min, respectively. Under these conditions, the removal efficiencies obtained for turbidity, suspended solids, chemical oxygen demand and total solids were 98.5, 99.2, 55.2 and 92.4?%, respectively. Corresponding energy and electrode consumptions were 0.143?kWh/kg SS and 0.010?kg Al/kg SS. For iron electrode, the optimum parameter values were found to be 7.8 pH, 20?A/m2 and 5?min, respectively. Under these conditions, removal efficiencies for turbidity, suspended solids, chemical oxygen demand and total solids were determined as 94.3, 99.1, 54.2, and 96.1?%, respectively. Energy and electrode consumptions were 0.0571?kWh/kg SS and 0.0206?kg Fe/kg SS, respectively. Settling characteristics of sludge produced during experiments carried out using both aluminum and iron electrodes were fairly good. The results showed that electrocoagulation method can be used efficiently for the treatment of marble processing wastewater under proper operating conditions.  相似文献   

16.
In the present work, a continuous catalytic wet peroxide oxidation fixed bed reactor was employed to treat a simulated wastewater sample with malachite green dye, as a contaminant. Natural perlite particle-supported nano-Fe3O4 catalyst was used as a fixed bed inside a reactor, and it was immobilized by a persistent magnetic field. The range of (perlite) particle sizes was from 100 to 1000 nm. The effects of various operating parameters, including temperature of the reactor, pH, initial hydrogen peroxide concentration and initial dye concentration, were investigated on the percentage removal of malachite green dye. Load of catalyst of 2 g and volumetric flow rate of 1 L/h were selected for all the tests. Maximum malachite green degradation was 99.5 ± 0.3%. This removal percentage was attained at temperature of 80 °C, pH = 6, initial dye concentration of 6 mg/L and initial hydrogen peroxide concentration of 100 mg/L. The process was isotherm, and the catalyst showed high catalytic activity in the steady-state condition. The loss of catalyst was less than 0.3%.  相似文献   

17.
为研究双金属催化剂去除有机污染物的效果,采用自制Fe/Ag催化剂对模拟苯酚废水进行了臭氧催化氧化处理。通过扫描电子显微镜(SEM)、比表面积分析仪(BET)和X射线衍射(XRD)对催化剂进行表征,并考察了催化剂类型、催化剂投加量和溶液初始pH值对降解效果的影响规律。结果表明:与Fe相比,Fe/Ag比表面积减少了22.8%,在Fe/Ag/O3与含苯酚废水的反应体系中,反应遵循臭氧直接作用和活性自由基(·OH、·O2、H2O2)共同作用的机理;Fe/Ag在反应过程中体现出良好的协同作用;300 mg/L的苯酚模拟废水在pH=6.3、Fe/Ag投加量为1.00 g的最优反应条件下经60 min反应,苯酚与化学需氧量(COD)去除率比单独臭氧氧化分别提高了18.4%和29.4%。  相似文献   

18.
混凝-催化氧化处理含油污水实验研究   总被引:2,自引:0,他引:2  
采用复合化学混凝及催化氧化联合工艺对油田生产废水进行了实验研究.结果表明:含油废水经混凝处理后,剩余ρ(CODcr )可以达到300 mg/L左右,剩余悬浮物质量浓度小于10mg/L;再经活性炭载Cu、Pd催化剂的深度处理,含油污水中的ρ(CODcr )值由315 mg/L降至50 mg/L以下,达到了国家的相关排放标准.催化剂可以再生重复使用.  相似文献   

19.
When a new wastewater treatment plant is being designed by computer simulation, detailed data about organic fractions of influent wastewater (measured as chemical oxygen demand) are usually not available, but knowledge of the typical ranges of these fractions is indispensable. The influent chemical oxygen demand fractions can substantially influence the results of simulation-based design such as reactor volumes, solids residence time, effluent quality, oxygen demand, sludge production, etc. This article attempts to give an overview of wastewater organic fractions as modeling parameters and presents new chemical oxygen demand fractionation results from Hungary. According to the data from literature, the ratio of chemical oxygen demand components in raw wastewater is very different and the average composition is as follows: Inert particulate =17.1 %, slowly biodegradable = 57.9 %, inert soluble = 7.8 % and readily biodegradable = 17.5 %. The Hungarian wastewater samples were analyzed according to STOWA (Dutch foundation for applied water research) protocol and the obtained results were not much different from those of literature ( inert particulate = 23.7 %, slowly biodegradable = 49.8 %, inert soluble = 4.6 % and readily biodegradable = 21.9 %), but some typical characteristics were observed.  相似文献   

20.
The influent concentration has a great effect on nutrients removal efficiency in vertical subsurface flow constructed wetland systems, but treatment performance response to different C: N: P ratios in the influent are unclear at present. At the first growing seasons, the effects of the plants present or not, season, the different C: N: P ratio in influent condition and their interaction on treatment performances were studied in the planted or the unplanted wetlands in greenhouse condition. Each set of units was operated at hydraulic loading rates of 40 L/d. Low, medium and high-strength (100, 200, 400 mg/L of chemical oxygen demand or 20, 40, 80 mg/L total nitrogen) synthetic sewage were applied as influent. According to the first growing season results, the average removal efficiencies for the unplanted and the planted wetlands were as follows: chemical oxygen demand (44–58 % and 55–61 % respectively), total nitrogen (26–49% and 31–54 %) and total phosphorus (36–64 % and 70–83 %). The both wetlands system was operated as an efficient treatment system of highest average removal rates of both chemical oxygen demand and total phosphorus when medium-strength synthetic sewage were applied. When high strength synthetic sewage was applied, the planted wetlands usually had a higher nutrients removal rates than the unplanted over the study period. The plants grew well under any high loading treatment over the study period. Anyhow, it also proved that the wetland systems have a good capacity to treat different strength wastewater in greenhouse condition.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号