首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The California Department of Toxic Substances Control (DTSC) gathered empirical data from sites contaminated with chlorinated volatile organic compounds and generated a vapor intrusion database. The database includes 52 sites across California with 213 buildings, of which, 53% are residential, and 47% are commercial/industrial (nonresidential). DTSC's objective is to improve its knowledge and understanding of vapor intrusion and derive empirical attenuation factors that are representative of the climatic conditions and types of buildings commonly found in the state. Filtering was applied to remove data of suspect quality that were potentially affected by background sources. After filtering to 600 pairs from 32 sites across California, a subslab attenuation factor (AF) was calculated yielding a 95th percentile of 0.005. After filtering to 2926 paired measurements from 39 sites across California, a soil vapor AF was calculated yielding a 95th percentile of 0.0009. The groundwater data was not analyzed due to the small size of the dataset. The AFs from this study are similar to AFs in a California-specific study by Lahvis and Ettinger (2021). Accordingly, converging lines of evidence suggest that vapor attenuation in California is different from what is observed nationwide by the United States Environmental Protection Agency (USEPA), where an AF of 0.03 was empirically derived and later recommended for initial screening of buildings for potential vapor intrusion exposure (USEPA, 2015).  相似文献   

2.
A value of 0.001 is recommended by the United States Environmental Protection Agency (USEPA) for its groundwater‐to‐indoor air Generic Attenuation Factor (GAFG), used in assessing potential vapor intrusion (VI) impacts to indoor air, given measured groundwater concentrations of volatile chemicals of concern (e.g., chlorinated solvents). The GAFG can, in turn, be used for developing groundwater screening levels for VI given target indoor air quality screening levels. In this study, we examine the validity and applicability of the GAFG both for predicting indoor air impacts and for determining groundwater screening levels. This is done using both analysis of published data and screening model calculations. Among the 774 total paired groundwater‐indoor air measurements in the USEPA's VI database (which were used by that agency to generate the GAFG) we found that there are 427 pairs for which a single groundwater measurement or interpolated value was applied to multiple buildings. In one case, up to 73 buildings were associated with a single interpolated groundwater value and in another case up to 15 buildings were associated with a single groundwater measurement (i.e., that the indoor air contaminant concentrations in all of the associated buildings were influenced by the concentration determined at a single point). In more than 70% of the cases (390 of 536 paired measurements in which horizontal building‐monitoring well distance was recorded) the monitoring wells were located more than 30 m (and one up to over 200 m) from the associated buildings. In a few cases, the measurements in the database even improbably implied that soil gas contaminant concentrations increased, rather than decreased, in an upward direction from a contaminant source to a foundation slab. Such observations indicate problematic source characterization within the data set used to generate the GAFG, and some indicate the possibility of a significant influence of a preferential contaminant pathway. While the inherent value of the USEPA database itself is not being questioned here, the above facts raise the very real possibility that the recommended groundwater attenuation factors are being influenced by variables or conditions that have not thus far been fully accounted for. In addition, the predicted groundwater attenuation factors often fall far beyond the upper limits of predictions from mathematical models of VI, ranging from screening models to detailed computational fluid dynamic models. All these models are based on the same fundamental conceptual site model, involving a vadose zone vapor transport pathway starting at an underlying uniform groundwater source and leading to the foundation of a building of concern. According to the analysis presented here, we believe that for scenarios for which such a “traditional” VI pathway is appropriate, 10?4 is a more appropriately conservative generic groundwater to indoor air attenuation factor than is the EPA‐recommended 10?3. This is based both on the statistical analysis of USEPA's VI database, as well as the traditional mathematical models of VI. This result has been validated by comparison with results from some well‐documented field studies.  相似文献   

3.
Shallow trichloroethene (TCE) groundwater and soil contamination associated with a Comprehensive Environmental Response, Compensation and Liability Act (CERCLA) Superfund Site in Michigan resulted in a vapor intrusion (VI) investigation of overlying condominium units. Units with data suggesting a complete VI pathway received subslab depressurization systems (SSDs). Performance monitoring following the installation of an SSD at one unit indicated that the indoor air TCE concentrations remained elevated, despite pressure field extension tests that showed the system should effectively reduce VI from soil gas. Therefore, a cost-efficient and incremental investigation was launched to identify other potential source(s) of TCE using a field-portable gas chromatograph/mass spectrometer (GS/MS). The combination of room-by-room air sampling, potential VI entry point sampling, and emission tests of potential sources were used, which resulted in successfully identifying a bedroom furniture set as an indoor source of TCE for the unit. Although many common household products are recognized as indoor sources of TCE, emissions from finished furniture products have not been widely discussed in the VI literature. The findings of this study indicate that off gassing from furniture can lead to TCE concentrations in indoor air that exceed regulatory guidelines.  相似文献   

4.
Generic indoor air:subslab soil gas attenuation factors (SSAFs) are important for rapid screening of potential vapor intrusion risks in buildings that overlie soil and groundwater contaminated with volatile chemicals. Insufficiently conservative SSAFs can allow high‐risk sites to be prematurely excluded from further investigation. Excessively conservative SSAFs can lead to costly, time‐consuming, and often inconclusive actions at an inordinate number of low‐risk sites. This paper reviews two of the most commonly used approaches to develop SSAFs: (1) comparison of paired, indoor air and subslab soil gas data in empirical databases and (2) comparison of estimated subslab vapor entry rates and indoor air exchange rates (IAERs). Potential error associated with databases includes interference from indoor and outdoor sources, reliance on data from basements, and seasonal variability. Heterogeneity in subsurface vapor plumes combined with uncertainty regarding vapor entry points calls into question the representativeness of limited subslab data and diminishes the technical defensibility of SSAFs extracted from databases. The use of reasonably conservative vapor entry rates and IAERs offers a more technically defensible approach for the development of generic SSAF values for screening. Consideration of seasonal variability in building leakage rates, air exchange rates, and interpolated vapor entry rates allows for the development of generic SSAFs at both local and regional scales. Limitations include applicability of the default IAERs and vapor entry rates to site‐specific vapor intrusion investigations and uncertainty regarding applicability of generic SSAFs to assess potential short‐term (e.g., intraday) variability of impacts to indoor air.  相似文献   

5.
Soil vapor extraction (SVE) is effective for removing volatile organic compound (VOC) mass from the vadose zone and reducing the potential for vapor intrusion (VI) into overlying and surrounding buildings. However, the relationship between residual mass in the subsurface and VI is complex. Through a series of alternating extraction (SVE on) and rebound (SVE off) periods, this field study explored the relationship and aspects of SVE applicable to VI mitigation in a commercial/light-industrial setting. The primary objective was to determine if SVE could provide VI mitigation over a wide area encompassing multiple buildings, city streets, and subsurface utilities and eliminate the need for individual subslab depressurization systems. We determined that SVE effectively mitigates offsite VI by intercepting or diluting contaminant vapors that would otherwise enter buildings through foundation slabs. Data indicate a measurable (5 Pa) influence of SVE on subslab/indoor pressure differential may occur but is not essential for effective VI mitigation. Indoor air quality improvements were evident in buildings 100 to 200 feet away from SVE including those without a measurable reversal of differential pressure across the slab or substantial reductions in subslab VOC concentration. These cases also demonstrated mitigation effects across a four-lane avenue with subsurface utilities. These findings suggest that SVE affects distant VI entry points with little observable impact on differential pressures and without relying on subslab VOC concentration reductions.  相似文献   

6.
The area surrounding the Colorado Department of Transportation Materials Testing Laboratory in Denver was the subject of intense investigation, involving the collection of thousands of ground water, soil-gas, and indoor air samples in order to investigate indoor air impacts associated with a subsurface release of chlorinated solvents. The preremediation portion of that data set is analyzed and reduced in this work to ground water–to-indoor air attenuation factors (αgw= the ratio of the measured indoor air concentration to the soil-gas concentration predicted to be in equilibrium with the local ground water concentration). The empirical αgw values for this site range from about 10−6 to 10−4 with an overall average of 3 × 10−5 (μg/L indoor air)/(μg/L soil gas). The analysis of this data set highlights the need for a thorough data review and data screening when using large data sets to derive empirical relationships between subsurface concentrations and indoor air. More specifically, it is necessary to identify those parts of the data that contain a strong vapor intrusion pathway signal, which generally will require concentrations well above reported detection levels combined with spatial or temporal correlation of subsurface and indoor concentrations.  相似文献   

7.
Vapor intrusion (VI) occurs when volatile contaminants in the subsurface migrate through the vadose zone into overlying buildings. The 2015 U.S. EPA petroleum VI guidance recommends that additional investigation of the VI risk from gasoline hydrocarbons at the underground storage tank (UST) sites is not necessary where the vertical distance between a building and a vapor source exceeds a recommended vertical screening distance. However, due to the lack of soil-gas data on the attenuation of ethylene dibromide (EDB), additional VI investigations to evaluate VI risk from EDB are recommended at UST sites with leaded gasoline releases containing EDB. We analyzed soil-gas and groundwater concentrations of EDB from eight petroleum UST sites using a new analytical method with soil-gas detection limit <0.16 μg/m3 EDB (VI screening level at the 10−6 risk level). The analysis included (1) assessing the frequency of EDB detections ≤0.16 μg/m3 at various vertical separation distances and (2) predicting vertical screening distances for EDB using the U.S. EPA PVIScreen model for different soil types in the vadose zone above dissolved-phase and LNAPL sources. Ranges of estimated aerobic biodegradation rate constants for EDB, air exchange rates for residential buildings, and source vapor concentrations for other constituents were combined with conservative estimates of EDB source concentrations as model inputs. Concentrations of EDB in soil-gas indicated that the U.S. EPA recommended vertical screening distances are protective of VI risk from EDB. Conversely, vertical screening distances predicted by modeling were >6 ft (1.8 m) for sites with sand and loam soil above dissolved phase sources and >15 ft (4.6 m) for sites with sand soil above LNAPL sources. This predicted dependence on the vapor source type and soil type in the vadose zone highlights the importance of soil characterization for VI screening at sites with EDB sources.  相似文献   

8.
Different types of data can be collected to evaluate whether or not vapor intrusion is a concern at sites impacted with volatile organic compound (VOC) contamination in the subsurface. Typically, groundwater, soil gas, or indoor air samples are collected to determine VOC concentrations in the different media. Sample results are evaluated using a “multiple lines of evidence” approach to interpret whether vapor intrusion is occurring. Data interpretation is often not straightforward because of many complicating factors, particularly in the evaluation of indoor air. More often than not, indoor air sample results are affected by indoor or other background sources making interpretation of concentration‐based data difficult using conventional sampling approaches. In this study, we explored the practicality of compound‐specific isotope analysis (CSIA) as an additional type of evidence to distinguish between indoor sources and subsurface sources (i.e., vapor intrusion). We developed a guide for decision‐making to facilitate data interpretation and applied the guidelines at four different test buildings. To evaluate the effectiveness of the CSIA method for vapor intrusion applications, we compared the interpretation from CSIA to interpretations based on data from two different investigation approaches: conventional sampling and on‐site GC/MS analysis. Interpretations using CSIA were found to be generally consistent with the other approaches. In one case, CSIA provided the strongest line of evidence that vapor intrusion was not occurring and that a VOC source located inside the building was the source of VOCs in indoor air.  相似文献   

9.
Subslab or shallow soil-gas data are often compared with indoor air concentration data in vapor intrusion (VI) evaluations. If no indoor air data are available or confounding sources are present, or if future scenarios are considered, the soil-gas data may be used to estimate the indoor air concentrations due to VI. The typical approach in risk assessments is to use the 95th percentile values from a set of concentration data. For VI studies, however, this rarely is an option because the data sets tend to be quite small. Therefore, various guidance documents urge the use of maximum soil-gas values. This may be reasonable for small residential buildings, but can lead to very conservatively biased estimates if applied to large industrial buildings with localized areas of contamination, especially given that the sampling locations may not be randomly selected and instead are biased toward worst-case locations. By this approach, VI guidance implicitly tolerates a large percentage of false positive decision errors to minimize the number of false negative decision errors. In this paper, implications of using maximum values are discussed and illustrated with data sets from a number of large industrial buildings at various sites. An alternative approach to using maximum soil-gas values is proposed that serves to reduce the number of false positive results while controlling the number of false negatives to an acceptable level.  相似文献   

10.
11.
A model is presented for estimating vapor concentrations in buildings because of volatilization from soil contaminated by non- aqueous phase liquids (NAPL) or from dissolved contaminants in ground water. The model considers source depletion, diffusive- dispersive transport of the contaminant of concern (COC) and of oxygen and oxygen-limited COC biodecay. Diffusive-advective transport through foundations and vapor losses caused by foundation cross-flow are considered. Competitive oxygen use by various species is assumed to be proportional to the product of the average dissolved-phase species concentration and a biopreference factor. Laboratory and field data indicate the biopreference factor to be proportional to the organic carbon partition coefficient for the fuel hydrocarbons studied. Predicted indoor air concentrations were sensitive to soil type and subbase permeability. Lower concentrations were predicted for buildings with shallow foundations caused by flushing of contaminants by cross-flow. NAPL source depletion had a large impact on average exposure concentration. Barometric pumping had a minor effect on indoor air emissions for the conditions studied. Risk-based soil cleanup levels were much lower when biodecay was considered because of the existence of a threshold source concentration below which no emissions occur. Computed cleanup levels at NAPL-contaminated sites were strongly dependent on total petroleum hydrocarbon (TPH) content and COC soil concentration. The model was applied to two field sites with gasoline-contaminated ground water. Confidence limits of predicted indoor air concentrations spanned approximately two orders of magnitude considering uncertainty in model parameters. Measured contaminant concentrations in indoor air were within model-predicted confidence limits.  相似文献   

12.
The United States Environmental Protection Agency (USEPA) is finalizing its vapor intrusion guidelines. One of the important issues related to vapor intrusion is background concentrations of volatile organic compounds (VOCs) in indoor air, typically attributed to consumer products and building materials. Background concentrations can exist even in the absence of vapor intrusion and are an important consideration when conducting site assessments. In addition, the development of accurate conceptual models that depict pathways for vapor entry into buildings is important during vapor intrusion site assessments. Sewer gas, either as a contributor to background concentrations or as part of the site conceptual model, is not routinely evaluated during vapor intrusion site assessments. The research described herein identifies an instance where vapors emanating directly from a sanitary sewer pipe within a residence were determined to be a source of tetrachloroethylene (PCE) detected in indoor air. Concentrations of PCE in the bathroom range from 2.1 to 190 µg/m3 and exceed typical indoor air concentrations by orders of magnitude resulting in human health risk classified as an “Imminent Hazard” condition. The results suggest that infiltration of sewer gas resulted in PCE concentrations in indoor air that were nearly two orders of magnitude higher as compared to when infiltration of sewer gas was not known to be occurring. This previously understudied pathway whereby sewers serve as sources of PCE (and potentially other VOC) vapors is highlighted. Implications for vapor intrusion investigations are also discussed.  相似文献   

13.
Vapor intrusion (VI) involves migration of volatile contaminants from subsurface through unsaturated soil into overlying buildings. In 2015, the US EPA recommended an approach for screening VI risks associated with gasoline releases from underground storage tank (UST) sites. Additional assessment of the VI risk from petroleum hydrocarbons was deemed unnecessary for buildings separated from vapor sources by more than recommended vertical screening distances. However, these vertical screening distances did not apply to potential VI risks associated with releases of former leaded gasoline containing 1,2-dichloroethane (1,2-DCA), because of a lack of empirical data on the attenuation of 1,2-DCA in soil gas. This study empirically evaluated 144 paired measurements of 1,2-DCA concentrations in soil gas and groundwater collected at 47 petroleum UST sites combined with BioVapor modeling. This included (1) assessing the frequency of 1,2-DCA detections in soil gas below 10−6 risk-based screening levels at different vertical separation distances and (2) comparing the US EPA recommended vertical screening distances with those predicted by BioVapor modeling. Vertical screening distances were predicted for different soil types using aerobic biodegradation rate constants estimated from the measured soil-gas data combined with conservative estimates of source concentrations. The modeling indicates that the vertical screening distance of 6 feet (1.8 m) recommended for dissolved-phase sources is applicable for 1,2-DCA below certain threshold concentrations in groundwater, while 15 feet (4.6 m) recommended for light nonaqueous phase liquid (LNAPL) sources is applicable for sites with clay and loam soils in the vadose zone, but not sand, if 1,2-DCA concentrations in groundwater exceed 150 μg/L. This dependence of the predicted vertical screening distances on soil type places added emphasis on proper soil characterization for VI screening at sites with 1,2-DCA sources. The soil-gas data suggests that a vertical screening distance of 15 feet (4.6 m) is necessary for both dissolved-phase and LNAPL sources.  相似文献   

14.
Groundwater elevation fluctuation has been recognized as one mechanism causing temporal indoor air volatile organic chemical (VOC) impacts in vapor intrusion risk assessment guidance. For dissolved VOC sources, groundwater table fluctuation shortens/lengthens the transport pathway, and delivers dissolved contaminants to soils that are alternating between water saturated and variably saturated conditions, thereby enhancing volatilization potential. To date, this mechanism has not been assessed with field data, but enhanced VOC emission flux has been observed in lab-scale and modeling studies. This work evaluates the impact of groundwater elevation changes on VOC emission flux from a dissolved VOC plume into a house, supplemented with modeling results for cyclic groundwater elevation changes. Indoor air concentrations, air exchange rates, and depth to groundwater (DTW) were collected at the study house during an 86-d constant building underpressurization test. These data were used to calculate changes in trichloroethylene (TCE) emission flux to indoor air, during a period when DTW varied daily and seasonally from about 3.1 to 3.4 m below the building foundation (BF). Overall, TCE flux to indoor air varied by about 50% of the average, without any clear correlation to changes in DTW or its change rate. To complement the field study, TCE surface emission fluxes were simulated using a one-dimensional model (HYDRUS 1D) for conditions similar to the field site. Simulation results showed time-averaged surface TCE fluxes for cyclic water-table elevations were greater than for stationary water-table conditions at an equivalent time-averaged water-table position. The magnitudes of temporal TCE emission flux changes were generally less than 50% of the time-averaged flux, consistent with the field site observations. Simulation results also suggested that TCE emission flux changes due to groundwater fluctuation are likely to be significant at sites with shallow groundwater (e.g., < 0.5 m BF) and permeable soil types (e.g., sand).  相似文献   

15.
Subslab soil gas sampling and analysis is a common line of evidence for assessing human health risks associated with subsurface vapor intrusion to indoor air for volatile organic compounds; however, conventional subslab sampling methods have generated data that show substantial spatial and temporal variability, which often makes the interpretation difficult. A new method of monitoring has been developed and tested that is based on a concept of integrating samples over a large volume of soil gas extracted from beneath the floor slab of a building to provide a spatially averaged subslab concentration. Regular field screening is also conducted to assess the trend of concentration as a function of the volume removed to provide insight into the spatial distribution of vapors at progressive distances away from the point of extraction. This approach minimizes the risk of failing to identify the areas of elevated soil vapor concentrations that may exist between discrete sample locations, and can provide information covering large buildings with fewer holes drilled through the floor. The new method also involves monitoring the extraction flow rate and transient vacuum response for mathematical analysis to help interpret the vapor concentration data and to support an optimal design for any subslab venting system that may be needed.  相似文献   

16.
A background indoor air study has been completed which includes the collection of indoor air samples from office buildings and schools. The anonymous study was designed with input from the U.S. Environmental Protection Agency and the Massachusetts Department of Environmental Protection. The sampling was implemented in 2013, 2014, and 2015 and included the collection of 25 school building samples and 61 office building samples. The study generated 14,668 new indoor air background data points, with samples collected from buildings located in 26 cities in 18 states, including Arizona, California, Connecticut, Indiana, Kansas, Maine, Massachusetts, Minnesota, Montana, New Hampshire, New Jersey, New York, Nevada, North Carolina, Ohio, Texas, Utah, and Washington. Indoor air background concentrations of target compound volatile organic compounds (VOCs) ranged from less than the laboratory method reporting limit of 0.044 μg/m3 to concentrations up to 1190 μg/m3, with hydrocarbon ranges from less than the reporting method limit of 10 μg/m3 to concentrations up to 3000 μg/m3. Some VOCs were identified ubiquitously in indoor air background, and some were identified at concentrations which exceeded risk-based regulatory screening levels. These study results provide useful and updated information on indoor air background and air quality in offices and schools and can be used in future regulatory guidance update considerations, for further examination of relationships between these data and residential study data, in human health risk assessments and risk communication, and in planning future studies.  相似文献   

17.
A chemiresistor microchemical sensor has been developed to detect and monitor volatile organic compounds in unsaturated and saturated subsurface environments. A controlled study was conducted at the HAZMAT Spill Center at the Nevada Test Site, where the sensor was tested under a range of temperature, moisture, and trichloroethylene (TCE) concentrations. The sensor responded rapidly when exposed to TCE placed in sand, and it also responded to decreases in TCE vapor concentration when clean air was vented through the system. Variations in temperature and water vapor concentration impacted baseline chemiresistor signals, but at high TCE concentrations the sensor response was dominated by the TCE exposure. Test results showed that the detection limit of the chemiresistor to TCE vapor in the presence of fluctuating environmental variables (i.e., temperature and water vapor concentration) was on the order of 1000 parts per million by volume, which is about an order of magnitude higher than values obtained in controlled laboratory environments. Automated temperature control and preconcentration is recommended to improve the stability and sensitivity of the chemiresistor sensor.  相似文献   

18.
Groundwater contamination associated with two former industrial facilities in Denver, Colorado, has led to concerns about vapor intrusion into residences adjacent to the facilities. 1,1,1-Trichloroethane (1,1,1-TCA), 1,1-dichloroethene (1,1-DCE), and trichloroethene (TCE) are the main contaminants of concern in groundwater, with trace levels of 1,2-dichloroethane (1,2-DCA) present at one of the sites. Indoor air monitoring programs have been ongoing at these two sites since 1998 and recent results have suggested that background, indoor source, 1,2-DCA has been increasing in the frequency of detection, and median and maximum concentration over the past several years. A lines of evidence evaluation was undertaken for both sites in order to document the predominance of indoor sources of 1,2-DCA. Evidence utilized included spatial evaluation of 1,2-DCA in indoor air; comparison of 1,2-DCA concentrations in mitigated and unmitigated homes; a phone survey to evaluate the potential for smoking to contribute to indoor air 1,2-DCA levels; evaluation of mitigation system effluent data; and an evaluation of volatile organic compound (VOC) ratios in groundwater and indoor air. The results of this evaluation indicated that smoking had no demonstrable influence on measured indoor air concentrations. In addition, it appears that consumer products have had a markedly increased influence on indoor air concentrations since 2005. Data from one of the industrial facilities at one of the sites also indicated that polyvinyl chloride (PVC) and vinyl composite floor adhesive used in a building remodel in 2005 apparently generated elevated levels of indoor 1,2-DCA and vinyl chloride, which have been sustained up to the present time.  相似文献   

19.
Detailed site investigations to assess potential inhalation exposure and risk to human health associated with the migration of petroleum hydrocarbon vapors from the subsurface to indoor air are frequently undertaken at leaking underground storage tank (UST) sites, yet documented occurrences of petroleum vapor intrusion are extremely rare. Additional assessments are largely driven by low screening‐level concentrations derived from vapor transport modeling that does not consider biodegradation. To address this issue, screening criteria were developed from soil‐gas measurements at hundreds of petroleum UST sites spanning a range of environmental conditions, geographic regions, and a 16‐year time period (1995 to 2011). The data were evaluated to define vertical separation (screening) distances from the source, beyond which, the potential for vapor intrusion can be considered negligible. The screening distances were derived explicitly from benzene data using specified soil‐gas screening levels of 30, 50, and 100 µg/m3 and nonparametric Kaplan‐Meier statistics. Results indicate that more than 95% of benzene concentrations in soil gas are ≤30 µg/m3 at any distance above a dissolved‐phase hydrocarbon source. Dissolved‐phase petroleum hydrocarbon sources are therefore unlikely to pose a risk for vapor intrusion unless groundwater (including capillary fringe) comes in contact with a building foundation. For light nonaqueous‐phase liquid (LNAPL) hydrocarbon sources, more than 95% of benzene concentrations in soil gas are ≤30 µg/m3 for vertical screening distances of 13 ft (4 m) or greater. The screening distances derived from this analysis are markedly different from 30 to 100 ft (10 to 30 m) vertical distances commonly found cited in regulatory guidance, even with specific allowances to account for uncertainty in the hydrocarbon source depth or location. Consideration of these screening distances in vapor intrusion guidance would help eliminate unnecessary site characterization at petroleum UST sites and allow more effective and sustainable use of limited resources.  相似文献   

20.
This paper provides a summary of a number of indoor air quality studies reporting concentrations of volatile organic compounds (VOCs) in indoor air samples collected from residential properties in North America and provides average values for certain statistics (percentiles, detection frequency, maximum). This compilation includes several VOCs that are commonly assessed in studies of subsurface vapor intrusion to indoor air, but may also be attributable to consumer products, building materials, or even outdoor air (ambient) sources, specifically benzene, carbon tetrachloride, chloroform, 1,1-dichloroethane, 1,1-dichloroethene, 1,2-dichloroethane, cis and trans-1,2-dichloroethene, ethylbenzene, methyl tert-butyl ether, methylene chloride, tetrachloroethene, trichloroethene, toluene, trichloro-1,2,2-trifluoroethane, 1,1,1-trichloroethane, vinyl chloride, and meta, para, and ortho-xylene. In studies spanning 1990 through 2005, eleven of these compounds were detected in more than 50% of samples collected, and for several compounds (benzene, carbon tetrachloride, chloroform, ethylbenzene, and tetrachloroethene) the lower and upper quintiles of the indoor air concentrations are within the range of typical risk-based target levels. These summary statistics may help interpret data collected during a vapor intrusion investigation and communicate the findings of indoor air quality studies to building occupants and other stakeholders. Similar studies have been published in the past, but there has been a gradual change in indoor air quality over time and a large amount of new data has been collected, so this paper provides more relevant information for current use than previous compilations.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号