首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
High arsenic levels in groundwater of the aquifers, belonging to the Pliocene terrestrial layers and Quaternary alluvial sediments, have become a significant problem for the inhabitants living in Sarkisla (Turkey). The main objective of this study was to determine the origin and arsenic contamination mechanisms of the Sarkisla drinking water aquifer systems. The highest arsenic concentrations were found in Pliocene layers and alluvial sediments with concentrations ranging from 2.1 to 155 mg/kg. These rocks are the main aquifers in the study area, and most of the drinking groundwater demand is met by these aquifers. Groundwater from the Pliocene aquifer is mainly Ca-HCO3 and Ca-SO4 water type with high EC values reaching up to 3,270 μS/cm, which is due to the sulfate dissolution in some parts of the alluvial aquifer. Stable isotope values showed that the groundwater was of meteoric origin. Tritium values for the groundwater were between 8.31 and 14.06 TU, representing a fast circulation in the aquifer. Arsenic concentrations in the aquifers were between 0.5 and 345 μg/L. The highest arsenic concentrations detected in the Pliocene aquifer system reached up to 345 μg/L with an average value of 60.38 μg/L. The arsenic concentrations of the wells were high, while the springs had lower arsenic concentrations. These springs are located in the upper parts of the study area where the rocks are less weathered. The hydrogeochemical properties demonstrated that the water–rock interaction processes in sulfide-bearing rocks were responsible for the remarkably high groundwater arsenic contamination in the study area. In the study area, the arsenic levels determined in groundwater exceeded the levels recommended by the WHO. Therefore, it is suggested that this water should not be used for drinking purposes and new water sources should be investigated.  相似文献   

2.
The Gilt Edge Superfund Site is a former heap-leach gold mine that currently is being remediated in the Black Hills of South Dakota. Mine runoff water is treated before release from the site. The field pH, before treatment, is about 3; the water contains arsenic at low levels and some trace metals at elevated levels, in addition to total dissolved solids concentrations of more than 1,900 mg/L. In the Keystone area of the Black Hills, naturally occurring arsenic has been detected at elevated concentrations in groundwater samples from wells. The City of Keystone’s Roy Street Well, which is not used currently, showed arsenic concentrations of 36 parts per billion and total dissolved solids of 320 mg/L. With field samples of water from the Gilt Edge site, a limestone-based method was successful in reducing trace metals concentrations to about 0.001 mg/L or less; at the Keystone site, the limestone method reduced arsenic levels to about 0.006 mg/L. The results are significant because previous research with the limestone-based method mainly had involved samples prepared with distilled water in the laboratory, in which interference of other ions such as sulfate did not occur. The research indicates the potential for broader applications of the limestone-based removal method, including scale-up work at field sites for water treatment.  相似文献   

3.
地下水砷污染分析   总被引:14,自引:0,他引:14  
阐述了含砷黄铁矿等含砷矿物以及岩石矿物附着砷等天然来源,同时从气候、环境地质以及水化学环境等方面分析了砷在地下水中的迁移和富集规律。研究表明:干旱、半干旱地区、封闭的地形地貌、断裂凹陷等外部环境有利于高砷地下水的形成,同时含水介质性质、地下水径流条件以及地下水中pH值、Eh值、不同的无机和有机组分对砷在地下水中迁移富集起着重要作用。在此基础上从砷的“来源—影响因素—影响过程—高砷形成”角度提出了地下水砷污染的成因模式,对砷中毒病区的环境问题调查与地下水砷污染的防治具有重要参考价值。  相似文献   

4.
Arsenic occurrence in groundwater near the Cimino-Vico volcanoes (central Italy) was analysed considering the hydrostratigraphy and structural setting and the shallow and deep flows interacting within the Quaternary volcanics. Groundwater is the local source of drinking water. As documented in the past, arsenic in the groundwater has become a problem, and the European maximum allowable contaminant level was recently lowered to 10 μg/L. Chemical analyses of groundwater were conducted, sampled over an area of about 900 km2, from 65 wells and springs representative of the volcanic aquifer and thermal waters. Considering the type of aquifer, the nature of the aquifer formation and its substratum, the hydrochemical data highlight that the arsenic content of the groundwater is mainly connected with the hydrothermal processes in the volcanic area. Thermal waters (54–60°C) fed from deep-rising fluids show higher arsenic concentrations (176–371 μg/L). Cold waters sampled from the volcanic aquifer are characterized by a wide variability in their arsenic concentration (1.6–195 μg/L), and about 62% exceed the limit of 10 μg/L. Where the shallow volcanic aquifer is open to deep-rising thermal fluids, relatively high arsenic concentrations (20–100 μg/L) are found. This occurs close to areas of the more recent volcano-tectonic structures.  相似文献   

5.
Core sediments from three disturbed boreholes (JOR, GHAT, and RAJ) and two undisturbed boreholes (DW1 and DW2) were collected in the study area of the Chapai-Nawabganj district of northwestern Bangladesh for geochemical analyses. In the study area, groundwater samples from fourteen As-contained private wells and five nested piezometers at both the DW1 and DW2 boreholes were also collected and analyzed. The groundwater arsenic concentrations in the uppermost aquifer (10–40 m of depth) range from 3 to 315 μg/L (mean 47.73 ± 73.41 μg/L), while the arsenic content in sediments range from 2 to 14 mg/kg (mean 4.36 ± 3.34 mg/kg). An environmental scanning electron microscope (ESEM) with an energy dispersive X-ray spectrometer was used to investigate the presence of major and trace elements in the sediments. Groundwaters in the study area are generally the Ca–HCO3 type with high concentrations of As, but low levels of Fe, Mn, NO3 ? and SO 4 ?2 . The concentrations of As, Fe, Mn decrease with depth in the groundwater, showing vertical geochemical variations in the study area. Statistical analysis clearly shows that As is closely associated with Fe and Mn in the sediments of the JOR core (r = 0.87, p < 0.05 for Fe and r = 0.78, p < 0.05 for Mn) and GHAT core (r = 0.95, p < 0.05 for Fe and r = 0.93, p < 0.05 for Mn), while As is not correlated with Fe and Mn in groundwater. The comparatively low Fe and Mn concentrations in some groundwater and the ESEM image revealed that siderite precipitated as a secondary mineral on the surface of the sediment particles. The correlations along with results of sequential extraction experiments indicated that reductive dissolution of FeOOH and MnOOH represents a mechanism for releasing arsenic into the groundwater.  相似文献   

6.
The Green Corridor in the lower reaches of Tarim River in northwestern China has an extreme hot and dry climate. Vegetation here, consisting of arbor, shrub and grass, relies on groundwater exceedingly. However, the increasing anthropogenic activities of large-scale agricultural reclamation and unreasonable water utilization in the upper and middle reaches caused the 321-km riverway in the lower reaches to dry up completely in 1972 and resulted in the sharp decline of groundwater, followed by the ruin of desert riparian vegetation on a large scale. The Green Corridor is on the verge of shrinking. Water has a key role in maintaining ecological balance and socioeconomic development. This paper, focused on the relationship between vegetation and groundwater, discusses (1) the change of groundwater table caused by the ecological water delivery carried out in the lower reaches of Tarim River; (2) the appropriate groundwater depth meeting the vegetation’s survival; (3) the minimum ecological flux and ecological water requirement for the growth of natural vegetation. It was shown that (1) based on the analysis of the monitoring data from the groundwater level of ten times water delivery, such an extensive artificial watering takes positive effect on raising the groundwater level along the two sides of the river; (2) a groundwater table depth of 2–4 m is probably the appropriate ecological water table level for the lower reaches of the Tarim River, and 6 m is the threshold for the local vegetation; (3) at the lower Tarim River, 1.157 × 10m3 of water flow is needed for itself. The longer the duration of water releases, the greater would be the groundwater rise and the larger the range of vegetation influenced. It was found that the duration and volume of water delivery was closely related to restoration of vegetation in the lower reaches of the Tarim River. The goal of this paper is to offer scientific evidences for water delivery in the rigorous areas to maintain an ecological balance.  相似文献   

7.
Anatolia region is one of the most seismically active regions in the world and has a considerably high level of geothermal energy potential. Some of these geothermal resources have been used for power generation and direct heating. Most of the high enthalpy geothermal systems are located in western part of Turkey. Alasehir is the most important geothermal site in western part of Turkey. Many geothermal wells have been drilled in Alasehir Plain to produce the geothermal fluid from the deep reservoir in the last 10 years. A blowout accident happened during a geothermal well drilling operation in Alasehir Plain, and significant amount of geothermal fluid surfaced out along the fault zone in three locations. When drilling string entered the reservoir rock about 1000 m, blowout occurred. As the well head preventer system was closed because of the blowout, high-pressure fluid surfaced out along the fault zone cutting the Neogene formation. In order to understand the geothermal fluid effects on groundwater chemistry, physical and chemical compositions of local cold groundwater were monitored from May 2012 to September 2014 in the study area. The geothermal fluid was found to be of Na–HCO3 water type, and especially, arsenic and boron concentrations reached levels as high as 3 and 127 mg/L, respectively. The concentrations of arsenic and boron in the geothermal fluid and groundwater exceeded the maximum allowable limits given in the national and international standards for drinking water quality. According to temporally monitored results, geothermal fluid has extremely high mineral content which influenced the quality of groundwater resources of the area where water resource is commonly used for agricultural irrigation.  相似文献   

8.
Groundwater pollution by arsenic is a major health threat in suburban areas of Hanoi, Vietnam. The present study evaluates the effect of the sedimentary environments of the Pleistocene and Holocene deposits, and the recharge systems, on the groundwater arsenic pollution in Hanoi suburbs distant from the Red River. At two study sites (Linh Dam and Tai Mo communes), undisturbed soil cores identified a Pleistocene confined aquifer (PCA) and Holocene unconfined aquifer (HUA) as major aquifers, and Holocene estuarine and deltaic sediments as an aquitard layer between the two aquifers. The Holocene estuarine sediments (approximately 25–40 m depth, 9.6–4.8 cal ka BP) contained notably high concentrations of arsenic and organic matter, both likely to have been accumulated by mangroves during the Holocene sea-level highstand. The pore waters in these particular sediments exhibited elevated levels of arsenic and dissolved organic carbon. Arsenic in groundwater was higher in the PCA (25–94 μg/L) than in the HUA (5.2–42 μg/L), in both the monitoring wells and neighboring household tubewells. Elevated arsenic concentration in the PCA groundwater was likely due to vertical infiltration through the arsenic-rich and organic-matter-rich overlying Holocene estuarine sediments, caused by massive groundwater abstraction from the PCA. Countermeasures to prevent arsenic pollution of the PCA groundwater may include seeking alternative water resources, reducing water consumption, and/or appropriate choice of aquifers for groundwater supply.  相似文献   

9.
Exposure to arsenic and fluoride through contaminated drinking water can cause serious health effects. In this study, the sources and occurrence of arsenic and fluoride contaminants in groundwater are analyzed in Dawukou area, northwest China, where inhabitants rely on groundwater as the source of drinking water. The triangular fuzzy numbers approach is adopted to assess health risk. The fuzzy risk assessment model incorporates the uncertainties that are caused by data gaps and variability in the degree of exposure to contaminants. The results showed that arsenic and fluoride in groundwater were mainly controlled by the dissolution–precipitation of Ca-arsenate and fluorite under weakly alkaline conditions. The arsenic and fluoride concentrations were higher in the shallow groundwater. The most probable risk values for arsenic and fluoride were 4.57 × 10?4 and 0.4 in the shallow groundwater, and 1.58 × 10?4 and 0.3 in the deep groundwater. Although the risks of fluoride were almost within the acceptable limit (<1.0), the risk values of arsenic were all beyond the acceptable levels of 10?6 for drinking water. Further, the local administration should pay more attention to the potential health risk through dietary intake and to the safety of deep water by ensuring it is not contaminated under prolonged pumping conditions. The fuzzy risk model treats the uncertainties associated with a quantitative approach and provides valuable information for decision makers when uncertainties are explicitly acknowledged, particularly for the variability in contaminants. This study can provide a new insight for solving data uncertainties in risk management.  相似文献   

10.
The impact of urbanization on groundwater quality is of special concern for water managers dealing with the provision of drinking water to large urban centers. Nitrate is one of the most common contaminants found in urban aquifers. This paper presents a case study aiming at evaluating the distribution and sources of nitrate in an urban aquifer in the city of Mar del Plata, Argentina. Four study zones under different land uses, including a pristine, a semi-rural, an intermediate, and an urban area, were evaluated as a part of this study. The three latter zones are linked by the groundwater flow system. The average nitrate concentration in the pristine area is 6.7 mg/L as nitrate and is over the permissible level of 50 mg/L for drinking water in the other areas. In the semi-rural area it ranges from 39.2 to 107.1 mg/L with an average value of 38.2 mg/L and the nitrate concentration tends to decrease in the intermediate zone to an average value of 38.2 mg/L; however, values above 60 mg/L are also observed there. Then the nitrate concentration in the urban area water is higher than that in the intermediate zonewater ranging from 48.2 to 100.3 mg/L with an average value of 67.3 mg/L. Data on the stable isotopes 15N and 18O in nitrate show that the main sources of nitrate in the study area are manure associated to agriculture uses and cesspools in the semi-rural area, and leakage of the sewage distribution network in the urban area, respectively. This is supported by a previous study which found that 20 % of the water flooding many underground structures in the city came from leakage of the sewage network. No evidence of nitrate attenuation by denitrification was found in the groundwater. This study has shown that aquifers in urban areas can be affected by agricultural activity in the upstream areas and leakage of the sewage network in the urban area.  相似文献   

11.
High As contents in groundwater were found in Rayen area and chosen for a detailed hydrogeochemical study. A total of 121 groundwater samples were collected from existing tube wells in the study areas in January 2012 and analyzed. Hydrogeochemical data of samples suggested that the groundwater is mostly Na–Cl type; also nearly 25.62 % of samples have arsenic concentrations above WHO permissible value (10 μg/l) for drinking waters with maximum concentration of aqueous arsenic up to 25,000 μg/l. The reducing conditions prevailing in the area and high arsenic concentration correlated with high bicarbonate and pH. Results show that arsenic is released into groundwater by two major phenomena: (1) through reduction of arsenic-bearing iron oxides/oxyhydroxides and Fe may be precipitated as iron sulfide when anoxic conditions prevail in the aquifer sediments and (2) transferring of As into the water system during water–acidic volcanic rock interactions.  相似文献   

12.
Groundwater arsenic survey in Cachar and Karimganj districts of Barak Valley, Assam shows that people in these two districts are drinking arsenic-contaminated (max. 350 μg/l) groundwater. 66% of tubewells in these two districts have arsenic concentration above the WHO guideline value of 10 μg/l and 26% tubewells have arsenic above 50 μg/l, the Indian standards for arsenic in drinking water. 90% of installed tubewells in these two districts are shallow depth (14–40 m). Shallow tubewells were installed in Holocene Newer Alluvium aquifers are characterised by grey to black coloured fine grained organic rich argillaceous sediments and are mostly arsenic contamination in groundwater. Plio-Pleistocene Older Alluvium aquifers composed of shale, ferruginous sandstone, mottle clay, pebble and boulder beds, which at higher location or with thin cover of Newer Alluvium sediments are safe in arsenic contamination in groundwater. 91% of tubewell water samples show significantly higher concentrations of iron beyond its permissible limit of 1 mg/l. The iron content in these two districts varies from 0.5 to as much as 48 mg/l. Most of the arsenic contaminated villages of Cachar and Karimganj districts are located in entrenched channels and flood plains of Newer Alluvium sediments in Barak-Surma-Langai Rivers system. However, deeper tubewells (>60 m) in Plio-Pleistocene Older Alluvium aquifers would be a better option for arsenic-safe groundwater. The arsenic in groundwater is getting released from associated Holocene sediments which were likely deposited from the surrounding Tertiary Barail hill range.  相似文献   

13.
The authors’ survey of the Ganga–Meghna–Brahmaputra (GMB) plain (area 569,749 km2; population >500 million) over the past 20 years and analysis of more than 220,000 hand tube-well water samples revealed groundwater arsenic contamination in the floodplains of the Ganga–Brahmaputra river (Uttar Pradesh, Bihar, Jharkhand, West Bengal, and Assam) in India and the Padma–Meghna–Brahmaputra river in Bangladesh. On average, 50 % of the water samples contain arsenic above the World Health Organization guideline value of 10 μg/L in India and Bangladesh. More than 100 million people in the GMB plain are potentially at risk. The authors’ medical team screened around 155,000 people from the affected villages and registered 16,000 patients with different types of arsenical skin lesions. Arsenic neuropathy and adverse pregnancy outcomes have been recorded. Infants and children drinking arsenic-contaminated water are believed to be at high risk. About 45,000 biological samples analyzed from arsenic-affected villages of the GMB plain revealed an elevated level of arsenic present in patients as well as non-patients, indicating that many are sub-clinically affected. In West Bengal and Bangladesh, there are huge surface water in rivers, wetlands, and flooded river basins. In the arsenic-affected GMB plain, the crisis is not over water scarcity but about managing the available water resources.  相似文献   

14.
Groundwater and surface water samples from 47 locations (28 groundwater, 10 tanks and 9 stream channel) were collected during the pre-monsoon (May–June) and post-monsoon season (November) from Chinnaeru River basin. Chinnaeru River basin is situated 30 km east of Hyderabad City and its area covers 250 km2 and falls in the Survey of India Toposheet No. 56 K/15. The extensive agricultural, industrial and urbanization activities resulted in the contamination of the aquifer. To study the contamination of groundwater, water samples were collected from an area and analyzed for major cations and anions. Various widely accepted methods such as salinity, sodium absorption ratio, Kelly’s ratio, residual sodium carbonate, soluble sodium percentage, permeability index and water quality index are used to classify groundwater and surface water (tank and stream) for drinking as well as irrigation purposes. Besides this, Piper trilinear diagram, Wilcox diagram, Doneen’s classification and Gibb’s plot were studied for geochemical controls, and hydrogeochemistry of groundwater and surface water samples were studied.  相似文献   

15.
High fluoride and arsenic concentrations in groundwater have led to serious health problems to local inhabitants at Yuncheng basin, Northern China. In this study, groundwater with high fluoride and arsenic concentration at Yuncheng basin was investigated. A majority of the samples (over 60%) belong to HCO3 type water. The predominant water type for the shallow groundwater collected from southern and eastern mountain areas was Ca/Mg-Ca-HCO3 types. For the shallow groundwater from flow through and discharge area it is Na-HCO3/SO4-Cl/SO4/Cl type. The predominant water type for the intermediate and deep groundwater is of Na/Ca/Mg-Ca-HCO3 type. According to our field investigation, fluoride concentration in groundwater ranges between 0.31 and 14.2 mg/L, and arsenic concentration ranges between 0.243 and 153.7 μg/L. Out of seventy collected groundwater samples, there are 31 samples that exceed the World Health Organization (WHO) standard of 1.5 mg/L for fluoride, and 15 samples exceeds the WHO standard of 10 μg/L for arsenic. Over 40% of high fluoride and arsenic groundwater are related to the Na-HCO3 type water, and the other fifty percent associated with Na-SO4-Cl/HCO3-SO4-Cl type water; little relation was found in calcium bicarbonate type water. A moderate positive correlation between fluoride and arsenic with pH were found in this study. It is due to the pH-dependent adsorption characteristics of F and As onto the oxide surfaces in the sediments. The observed negative correlation between fluoride and calcium could stem from the dissolution equilibrium of fluorite. The high concentration of bicarbonate in groundwater can serve as a powerful competitor and lead to the enrichment of fluoride and arsenic in groundwater. Most of the groundwater with high fluoride or arsenic content has nitrate content about or over 10 mg/L which, together with the observed positive correlations between nitrate and fluoride/arsenic, are indicative of common source of manmade pollution and of prevailing condition of leaching in the study area.  相似文献   

16.
由于地表水资源稀缺,地下水是塔里木盆地南缘绿洲带重要用水水源,因此,系统查明该区地下水砷氟碘的分布及成因至关重要。基于塔里木盆地南缘绿洲带233组地下水水样检测结果,分析不同含水层中高砷、高氟和高碘地下水的空间分布及水化学特征,结合研究区地质、水文地质条件和地下水赋存环境进一步揭示影响地下水砷氟碘的来源、迁移与富集的水文地球化学过程。结果表明:地下水砷、氟、碘浓度变化范围分别为1.091.2 μg/L、0.0128.31 mg/L、10.02 637.0 μg/L。地下水高砷、高氟和高碘水样分别占总水样的7.3%、47.2%和11.6%,砷氟碘共富集占比为3.0%。砷氟碘共富集地下水主要分布于研究区中部的民丰县,水化学类型主要为Cl·SO4-Na型。自补给区至过渡区再至蒸发区,地下水氟、碘浓度明显增大,砷浓度在过渡区和蒸发区均较大;砷氟碘共富集地下水取样点主要分布于36.060.0 m深度的浅层承压含水层中。浅层地下水受蒸发作用和矿物溶解沉淀作用的影响,随砷氟碘富集项的增多而增大。第四纪成因类型中风积物对氟浓度的影响较大,洪积-湖积物对砷和碘浓度的影响较大。细粒岩性、平缓的地形、地下水浅埋条件、偏碱性的地下水环境、微生物降解作用下有机质介导的矿物溶解是利于砷氟碘共富集的主要机制。  相似文献   

17.
18.
The Duna-Tisza Interfluve, Hungary has an agricultural economy but is plagued by severe problems of soil and wetland salinization despite 200 years of intensive research. The study’s objective was to determine the origin of salts and the mechanisms of salinity distribution. To this end, flow-patterns and chemistry of groundwater were evaluated in a 100 km?×?65 km area, with emphasis on the Kolon- and Kelemenszék Lakes region. The lakes are located 13 km apart and have chemically contrasting water and soil types. Two groundwater flow-domains were identified: a gravity-drive meteoric fresh water and an over-pressured deeper domain of saline water. The waters are channeled by a highly permeable gravel aquifer to the surface and may merge near Kelemenszék Lake, causing it to be saline. Kolon Lake receives meteoric groundwater only, hence its fresh chemical character. The cross-formational ascent of the deep waters, combined with the gravitational systems’ geometry and the flow-channeling effect of the near-surface rocks, explains the contrasting chemistry between lakes, and the origin and pattern of soil salinization. The scheme is proposed as a generally valid hydrogeological profile for the interfluve, and has been named the Duna-Tisza Interfluve Hydrogeological Type Section.  相似文献   

19.
The distribution of radon in ground and surface water samples in Sankey Tank and Mallathahalli Lake areas was determined using Durridge RAD-7 analyzer with RAD H2O accessory. The radiation dose received by an individual falling under different age groups (viz., 3 months; 1, 5, 10, 15 years and adult) depending upon their average annual water consumption rate was attempted. The mean radon activity in surface water of Sankey Tank and Mallathahalli Lake was 7.24 ± 1.48 and 11.43 ± 1.11 Bq/L, respectively. The average radon activities ranged from 11.6 ± 1.7 to 381.2 ± 2.0 Bq/L and 1.50 ± 0.83 to 18.9 ± 1.59 Bq/L, respectively, in 12 groundwater samples each around Sankey Tank and Mallathahalli Lake areas. Majority of the measured groundwater samples (viz., 100 % in Sankey Tank area and 75 % in Mallathahalli Lake area) showed mean radon values above the EPA’s maximum contaminant level of 11.1 Bq/L and only 66.67 % of samples in Sankey Tank area showed radon above the WHO and EU’s reference level of 100 Bq/L. The overall radiation dose due to radon emanating from water in the study area was increasing with increase in age and water consumption rates, but significantly lower than UNSCEAR and WHO recommended limit of 1 mSv/year except for few groundwater samples in Sankey Tank area (i.e., 0.92, 0.99 and 1.39 mSv/year). The radiation dose rate received by bronchial epithelium via inhalation was very high compared to that by stomach walls via ingestion.  相似文献   

20.
The Cuatrociénegas area is useful for the investigation of the effect of groundwater extraction in the Chihuahuan freshwater xeric ecoregion. It has been investigated at this time using a selection of geochemical indicators (major, minor and trace elements) and δ34S data, to characterize the origin of groundwater, the main geochemical processes and the mineral/groundwater interactions controlling the baseline geochemistry. The area is composed of limestones of Mesozoic age, with a composite thickness of about 500 m, overlaid by basin fill (poorly consolidated young sediments). Substantial water extraction and modification of natural discharges from the area along the last century have produced a detrimental impact on ecosystem structure and function. Water–rock interactions, mixing and evaporative processes dominate the baseline groundwater quality. Natural recharge is HCO3–Ca type in equilibrium with calcite, low salinity (TDS?<?500 mg/L), Cl? lower than 11 mg/L and average Li+ concentration of 0.005 mg/L. Along the groundwater flow systems, δ34S evidence and mass transfer calculations indicate that Cretaceous gypsum dissolution and dedolomitization reactions adjust water composition to the SO4–Ca type. The increase of water–rock interaction is reflected by Cl? values increase (average 68 mg/L), TDS up to about 1500 mg/L and an average Li+ concentration of 0.063 mg/L. Calculations with chemical geothermometers indicate that temperature at depth could be at maximum of 15–20 °C higher than field-measured temperature for pozas. After groundwater is discharged to the surface, chemical evolution continues; water evaporation, CO2 degassing and precipitation of minerals such as gypsum, calcite and kaolinite represent the final processes and reactions controlling water chemical composition.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号