首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 876 毫秒
1.
Techniques for characterizing the hydraulic properties and groundwater flow processes of aquifers are essential to design hydrogeologic conceptual models. In this study, rapid time series temperature profiles within open‐groundwater wells in fractured rock were measured using fiber optic distributed temperature sensing (FO‐DTS). To identify zones of active groundwater flow, two continuous electrical heating cables were installed alongside a FO‐DTS cable to heat the column of water within the well and to create a temperature difference between the ambient temperature of the groundwater in the aquifer and that within the well. Additional tests were performed to examine the effects of pumping on hydraulic fracture interconnectivity around the well and to identify zones of increased groundwater flow. High‐ and low‐resolution FO‐DTS cable configurations were examined to test the sensitivities of the technique and compared with downhole video footage and geophysical logging to confirm the zones of active groundwater flow. Two examples are presented to demonstrate the usefulness of this new technique for rapid characterization of fracture zones in open boreholes. The combination of the FO‐DTS and heating cable has excellent scope as a rapid appraisal tool for borehole construction design and improving hydrogeologic conceptual models.  相似文献   

2.
Leaf AT  Hart DJ  Bahr JM 《Ground water》2012,50(5):726-735
Subsurface heterogeneity in hydraulic properties and processes is a fundamental challenge in hydrogeology. We have developed an improved method of borehole dilution testing for hydrostratigraphic characterization, in which distributed temperature sensing (DTS) is used to monitor advective heat movement. DTS offers many advantages over conventional technologies including response times in the order of seconds rather than minutes, the ability to profile temperature synoptically in a well without disturbing the fluid column, sensitivity to a wider range of flow rates than conventional spinner and heat pulse flow meters, and the ease of interpretation. Open-well thermal dilution tests in two multiaquifer wells near Madison, Wisconsin, provided detailed information on the borehole flow regimes, including flow rates and the locations of inflows from both fractures and porous media. The results led to an enhanced understanding of flow in a hydrostratigraphic unit previously conceptualized as homogenous and isotropic.  相似文献   

3.
Identifying flows into, out of, and across boreholes is important for characterizing aquifers, determining the depth at which water enters boreholes, and determining the locations and rates of outflow. This study demonstrates how Single Borehole Dilution Tests (SBDTs) carried out under natural head conditions provide a simple and cheap method of identifying vertical flow within boreholes and determining the location of in‐flowing, out‐flowing, and cross‐flowing fractures. Computer simulations were used to investigate the patterns in tracer profiles that arise from different combinations of flows. Field tracer tests were carried out using emplacements of a saline tracer throughout the saturated length of boreholes and also point emplacements at specific horizons. Results demonstrated that SBDTs can be used to identify flowing fractures at the top and bottom of sections of vertical flow, where there is a change in vertical flow rate within a borehole, and also where there are consistent decreases in tracer concentration at a particular depth. The technique enables identification of fractures that might be undetected by temperature and electrical conductance logging, and is a simple field test that can be carried out without pumping the borehole.  相似文献   

4.
Borehole flowmeters that measure horizontal flow velocity and direction of groundwater flow are being increasingly applied to a wide variety of environmental problems. This study was carried out to evaluate the measurement accuracy of several types of flowmeters in an unconsolidated aquifer simulator. Flowmeter response to hydraulic gradient, aquifer properties, and well‐screen construction was measured during 2003 and 2005 at the U.S. Geological Survey Hydrologic Instrumentation Facility in Bay St. Louis, Mississippi. The flowmeters tested included a commercially available heat‐pulse flowmeter, an acoustic Doppler flowmeter, a scanning colloidal borescope flowmeter, and a fluid‐conductivity logging system. Results of the study indicated that at least one flowmeter was capable of measuring borehole flow velocity and direction in most simulated conditions. The mean error in direction measurements ranged from 15.1° to 23.5° and the directional accuracy of all tested flowmeters improved with increasing hydraulic gradient. The range of Darcy velocities examined in this study ranged 4.3 to 155 ft/d. For many plots comparing the simulated and measured Darcy velocity, the squared correlation coefficient (r2) exceeded 0.92. The accuracy of velocity measurements varied with well construction and velocity magnitude. The use of horizontal flowmeters in environmental studies appears promising but applications may require more than one type of flowmeter to span the range of conditions encountered in the field. Interpreting flowmeter data from field settings may be complicated by geologic heterogeneity, preferential flow, vertical flow, constricted screen openings, and nonoptimal screen orientation.  相似文献   

5.
Forced gradient tracer tests between two boreholes can be used to study contaminant transport processes at the small field scale or investigate the transport properties of an aquifer. Full depth tests, in which tracer samples are collected just from the discharge of the abstraction borehole, often give rise to breakthrough curves with multiple peaks that are usually attributed to different flow paths through the aquifer that can rarely be identified from the test results alone. Tests in selected levels of the aquifer, such as those between packer‐isolated sections of the boreholes, are time consuming, expensive; and the identification of major transport pathways is not guaranteed. We present a method for simultaneously conducting multiple tracer tests covering the full depth of the boreholes, in which tracer sampling and monitoring is carried out by a novel multilevel sampling system allowing high frequency and cumulative sampling options. The method is applied to a tracer test using fluorescein conducted in the multilayered sandstone aquifer beneath the city of Birmingham, UK, producing six well‐defined tracer breakthrough curves.  相似文献   

6.
Major challenges exist in delineating bedrock fracture zones because these cause abrupt changes in geological and hydrogeological properties over small distances. Borehole observations cannot sufficiently capture heterogeneity in these systems. Geophysical techniques offer the potential to image properties and processes in between boreholes. We used three‐dimensional cross borehole electrical resistivity tomography (ERT) in a 9 m (diameter) × 15 m well field to capture high‐resolution flow and transport processes in a fractured mudstone contaminated by chlorinated solvents, primarily trichloroethylene. Conductive (sodium bromide) and resistive (deionized water) injections were monitored in seven boreholes. Electrode arrays with isolation packers and fluid sampling ports were designed to enable acquisition of ERT measurements during pulsed tracer injections. Fracture zone locations and hydraulic pathways inferred from hydraulic head drawdown data were compared with electrical conductivity distributions from ERT measurements. Static ERT imaging has limited resolution to decipher individual fractures; however, these images showed alternating conductive and resistive zones, consistent with alternating laminated and massive mudstone units at the site. Tracer evolution and migration was clearly revealed in time‐lapse ERT images and supported by in situ borehole vertical apparent conductivity profiles collected during the pulsed tracer test. While water samples provided important local information at the extraction borehole, ERT delineated tracer migration over spatial scales capturing the primary hydrogeological heterogeneity controlling flow and transport. The fate of these tracer injections at this scale could not have been quantified using borehole logging and/or borehole sampling methods alone.  相似文献   

7.
The effect of array configuration, that is, number, layout, and spacing, on the performance of multiple borehole heat exchangers (BHEs) is generally known under the assumption of fully conductive transport. The effect of groundwater flow on BHE performance is also well established, but most commonly for single BHEs. In multiple‐BHE systems the effect of groundwater advection can be more complicated due to the induced thermal interference between the boreholes. To ascertain the influence of groundwater flow and borehole arrangement, this study investigates single‐ and multi‐BHE systems of various configurations. Moreover, the influence of energy load balance is also examined. The results from corresponding cases with and without groundwater flow as well as balanced and unbalanced energy loads are cross‐compared. The groundwater flux value, 10?7 m/s, is chosen based on the findings of previous studies on groundwater flow interaction with BHEs and thermal response tests. It is observed that multi‐BHE systems with balanced loads are less sensitive to array configuration attributes and groundwater flow, in the long‐term. Conversely, multi‐BHE systems with unbalanced loads are influenced by borehole array configuration as well as groundwater flow; these effects become more pronounced with time, unlike when the load is balanced. Groundwater flow has more influence on stabilizing loop temperatures, compared to array characteristics. Although borehole thermal energy storage (BTES) systems have a balanced energy load function, preliminary investigation on their efficiency shows a negative impact by groundwater which is due to their dependency on high temperature gradients between the boreholes and surroundings.  相似文献   

8.
Cross-borehole flowmeter tests have been proposed as an efficient method to investigate preferential flowpaths in heterogeneous aquifers, which is a major task in the characterization of fractured aquifers. Cross-borehole flowmeter tests are based on the idea that changing the pumping conditions in a given aquifer will modify the hydraulic head distribution in large-scale flowpaths, producing measurable changes in the vertical flow profiles in observation boreholes. However, inversion of flow measurements to derive flowpath geometry and connectivity and to characterize their hydraulic properties is still a subject of research. In this study, we propose a framework for cross-borehole flowmeter test interpretation that is based on a two-scale conceptual model: discrete fractures at the borehole scale and zones of interconnected fractures at the aquifer scale. We propose that the two problems may be solved independently. The first inverse problem consists of estimating the hydraulic head variations that drive the transient borehole flow observed in the cross-borehole flowmeter experiments. The second inverse problem is related to estimating the geometry and hydraulic properties of large-scale flowpaths in the region between pumping and observation wells that are compatible with the head variations deduced from the first problem. To solve the borehole-scale problem, we treat the transient flow data as a series of quasi-steady flow conditions and solve for the hydraulic head changes in individual fractures required to produce these data. The consistency of the method is verified using field experiments performed in a fractured-rock aquifer.  相似文献   

9.
Abstract

Preferential flow pathways in a fractured aquifer may yield abrupt reductions of the water velocity in a well. We propose a new device for measuring low (5–13 cm d-1) velocities in wells originating from fractures at different depths. The presented flowmeter has been applied in a well in the Bari (southern Italy) fractured aquifer. In the same well, the horizontal flowmeter velocity (9.6 cm d-1) at 0.5 m depth was compared with velocity (8 cm d-1) derived from a field tracer test, providing a value 16.5% higher. Moreover, the flowmeter measurements at 1.5 m depth gave a horizontal velocity of 7.2 cm d-1, which is 11% less than water flow velocity estimated from the field test. The new flowmeter implements the tracer point-dilution method in a plastic (PVC) pipe by causing the water flow to pass through an artificial filter. Laboratory calibration tests have confirmed the good performance of the proposed flowmeter technique, even for water flow up to 300 cm d-1. The flowmeter was sensitive to 0.1 cm d-1, with a detection limit of 1.5 cm d-1, i.e. half the measurable flow velocity of existing flowmeters in wells.

Editor D. Koutsoyiannis; Associate editor S. Grimaldi  相似文献   

10.
Characterization of a multilayer aquifer using open well dilution tests   总被引:1,自引:0,他引:1  
West LJ  Odling NE 《Ground water》2007,45(1):74-84
An approach to characterization of multilayer aquifer systems using open well borehole dilution is described. The approach involves measuring observation well flow velocities while a nearby extraction well is pumped by introducing a saline tracer into observation wells and collecting dilution vs. depth profiles. Inspection of tracer profile evolution allows discrete permeable layers within the aquifer to be identified. Dilution profiles for well sections between permeable layers are then converted into vertical borehole flow velocities and their evolution, using an analytic solution to the advection-dispersion equation applied to borehole flow. The dilution approach is potentially able to measure much smaller flow velocities that would be detectable using flowmeters. Vertical flow velocity data from the observation wells are then matched to those generated using a hydraulic model of the aquifer system, "shorted" by the observation wells, to yield the hydraulic properties of the constituent layers. Observation well flow monitoring of pumping tests represents a cost-effective alternative or preliminary approach to pump testing each layer of a multilayer aquifer system separately using straddle packers or screened wells and requires no prior knowledge of permeable layer depths and thicknesses. The modification described here, of using tracer dilution rather than flowmeter logging to obtain well flow velocities, allows the approach to be extended to greater well separations, thus characterizing a larger volume of the aquifer. An example of the application of this approach to a multilayer Chalk Aquifer in Yorkshire, Northeast England, is presented.  相似文献   

11.
Abstract

Two topographically similar adjacent catchments near Johannesburg, South Africa, one suburban, the other natural grassland, were monitored over a five year period to detect differences in runoff and hydrological balance. A network of raingauges, boreholes, flow gauges and water meters was installed. Evapotranspiration was modelled using observed weather data. Groundwater was estimated from tracer and other borehole tests. Surface runoff from the undeveloped and suburban catchments was 4% and 15% of rainfall respectively. Evapotranspiration was 63% of rainfall for both catchments. Sewage outflow was 83% of water consumption for the suburban catchment. Little change in water table level occurred in the suburban catchment, and garden watering probably balanced the high evaporation. Piped water supply was 16% of the precipitation on the catchment.  相似文献   

12.
Advanced borehole-geophysical methods were used to assess the geohydrology of fractured crystalline bedrock at five test boreholes in southwestern Manhattan Island, New York, in preparation for construction of a third water tunnel for New York City. The boreholes penetrated gneiss and other crystalline bedrock that has an overall southwest to northwest dipping foliation with a 60° dip. Most of the fractures encountered are either nearly horizontal or have moderate northwest dip azimuths. Fracture indexes range from 0.25 to 0.44 fracture per foot (0.3 m) of borehole.
Electromagnetic (EM) and heat-pulse flowmeter logs obtained under ambient and pumping conditions, together with other geophysical logs, indicate transmissive fracture zones in each borehole. Pumping tests of each borehole indicated transmissivity ranges from <2 to 360 ft2/day (0.2 to 33 m2/day). Ground water appears to flow within an interconnected fracture network toward the south and west within the study area. No correlation was indicated between the fracture index and the total borehole transmissivity.  相似文献   

13.
This paper reviews different borehole flowmeter analysis methods and evaluates their applicability to a test site composed of fluvial deposits. Results from tracer and aquifer tests indicate that the aquifer is highly heterogeneous and that low-K skin effects exist at the wells. Borehole flowmeter tests were performed at 37 wells. An appropriate method for calculating borehole flowmeter K values was developed based on results from multiwell pumping tests, single-well pumping tests, and slug tests. The flowmeter data produced 881 K values. The trends and the magnitude of the K values are consistent with results from geologic investigations, recirculating tracer tests, and large-scale multiwell pumping tests. The field tests illustrate that high-K deposits can significantly affect ground-water flows in some heterogeneous fluvial aquifers.  相似文献   

14.
Tracer tests represent the most appropriate approach for assessing hydrodispersive parameters such as transversal and longitudinal dispersivities or kinematic porosity on an aquifer scale. They are generally carried out by injecting a tracer in a borehole and measuring its concentration over time in neighboring boreholes by extracted volume sampling or downhole measurements. Logging is one of the most suitable methods for evaluating fissured reservoirs. But short circuits between fractures with different hydraulic potential through boreholes induce mixing phenomena that cannot be avoided without packers. This mixing can shift the breakthrough curves deduced from the logs for each producing fracture and distort determination of their location.
The method proposed in this paper aims at measuring the flow rate and the solute breakthrough for hydraulically active fractures, in open boreholes. It involves estimating a velocity profile along the borehole column by the analysis of two successive logs: a shift function according to depth is thus determined by comparison between log portions on each successive one. The velocity gradients reflect the inward or outward flow rates produced by each fracture. On the basis of these flow rates, it is possible to determine the mixing effects inside the borehole and then to plot unbiased breakthrough curves for each producing fracture.
This method was applied at a granitic site in the eastern Pyrenees. In spite of some questionable limitations, the results showed that the method seems adapted to situations with many fractures. The precise hydraulic pattern which is obtained at the borehole scale is discussed in terms of a dual porosity model. Furthermore, interpretation of the breakthrough curves for fractures corrected for mixing effects revealed that Peclet numbers are strongly underestimated if this phenomenon is not considered.  相似文献   

15.
We present a combined 3-D geoelectric and seismic tomography study conducted on the large Åknes rockslide in western Norway. Movements on the slope are strongly influenced by water infiltration, such that the hydrogeological regime is considered as a critical factor affecting the slope stability. The aim of our combined geophysical study was to identify and visualize the main shallow tension fractures and to determine their effect on hydraulic processes by comparing the geophysical results with information from borehole logging and tracer tests. To resolve the complex subsurface conditions of the highly fractured rock mass, a three-dimensional set-up was chosen for our seismic survey. To map the water distribution within the rock mass, a pattern of nine intersecting 2-D geoelectric profiles covered the complete unstable slope. Six of them that crossed the seismic survey area were considered as a single data set in a 3-D inversion. For both methods, smoothing-constraint inversion algorithms were used, and the forward calculations and parameterizations were based on unstructured triangular meshes. A pair of parallel shallow low-velocity anomalies (< 1400 m/s) observed in the final seismic tomogram was immediately underlain by two anomalies with resistivities <13 kΩm in the resistivity tomogram. In combination with borehole logging results, the low-velocity and resistivity anomalies could be associated with the drained and water-filled part of the tension fractures, respectively. There were indications from impeller flowmeter measurements and tracer tests that such tension fractures intersected several other water-filled fractures and were responsible for distinct changes of the main groundwater flow paths.  相似文献   

16.
Fractured rocks have presented formidable challenges for accurately predicting groundwater flow and contaminant transport. This is mainly due to our difficulty in mapping the fracture‐rock matrix system, their hydraulic properties and connectivity at resolutions that are meaningful for groundwater modeling. Over the last several decades, considerable effort has gone into creating maps of subsurface heterogeneity in hydraulic conductivity (K) and specific storage (Ss) of fractured rocks. Developed methods include kriging, stochastic simulation, stochastic inverse modeling, and hydraulic tomography. In this article, I review the evolution of various heterogeneity mapping approaches and contend that hydraulic tomography, a recently developed aquifer characterization technique for unconsolidated deposits, is also a promising approach in yielding robust maps (or tomograms) of K and Ss heterogeneity for fractured rocks. While hydraulic tomography has recently been shown to be a robust technique, the resolution of the K and Ss tomograms mainly depends on the density of pumping and monitoring locations and the quality of data. The resolution will be improved through the development of new devices for higher density monitoring of pressure responses at discrete intervals in boreholes and potentially through the integration of other data from single‐hole tests, borehole flowmeter profiling, and tracer tests. Other data from temperature and geophysical surveys as well as geological investigations may improve the accuracy of the maps, but more research is needed. Technological advances will undoubtedly lead to more accurate maps. However, more effort should go into evaluating these maps so that one can gain more confidence in their reliability.  相似文献   

17.
Deep observation boreholes in the vicinity of active production wells in Honolulu, Hawaii, exhibit the anomalous condition that fluid-column electrical conductivity logs and apparent profiles of pore-water electrical conductivity derived from induction conductivity logs are nearly identical if a formation factor of 12.5 is assumed. This condition is documented in three boreholes where fluid-column logs clearly indicate the presence of strong borehole flow induced by withdrawal from partially penetrating water-supply wells. This result appears to contradict the basic principles of conductivity-log interpretation. Flow conditions in one of these boreholes was investigated in detail by obtaining flow profiles under two water production conditions using the electromagnetic flowmeter. The flow-log interpretation demonstrates that the fluid-column log resembles the induction log because the amount of inflow to the borehole increases systematically upward through the transition zone between deeper salt water and shallower fresh water. This condition allows the properties of the fluid column to approximate the properties of water entering the borehole as soon as the upflow stream encounters that producing zone. Because this condition occurs in all three boreholes investigated, the similarity of induction and fluid-column logs is probably not a coincidence, and may relate to aquifer response under the influence of pumping from production wells.  相似文献   

18.
Groundwater sampling from open boreholes in fractured‐rock aquifers is particularly challenging because of mixing and dilution of fluid within the borehole from multiple fractures. This note presents an alternative to traditional sampling in open boreholes with packer assemblies. The alternative system called ZONFLO (zonal flow) is based on hydraulic control of borehole flow conditions. Fluid from discrete fractures zones are hydraulically isolated allowing for the collection of representative samples. In rough‐faced open boreholes and formations with less competent rock, hydraulic containment may offer an attractive alternative to physical containment with packers. Preliminary test results indicate a discrete zone can be effectively hydraulically isolated from other zones within a borehole for the purpose of groundwater sampling using this new method.  相似文献   

19.
A comprehensive reinterpretation of the available gravity, magnetic, geothermal, geological and borehole information has been made of the Laguna Salada Basin to establish a 3D model of the basement and sedimentary infill. According to statistical spectral analysis, the residual gravity anomaly is due to sources with a mean regional depth of 2.8 km. The topography of the basement was obtained from a three‐dimensional inversion carried out in the wavenumber domain using an iterative scheme. The maximum density contrast of ?300 kg/m3 estimated from previous studies and the mean depth of 2.5 km finally constrained this inversion. The resulting model indicated that the sedimentary infill is up to 4.2 km thick at its deepest point. According to the gravity‐derived basement topography, the basin presents an asymmetry (i.e. it is of the half‐graben type). It is deeper to the east, where it is delimited from the Sierra Cucapah by a step fault. By contrast, the limit with the Sierra de Juarez is a gently sloping fault (i.e. a listric fault). The basement is not even, but it comprises a series of structural highs and lows. N–S to NW–SE and E–W to NE–SW faults delimit these structural units. The magnetic modelling was constrained by (i) the gravity‐derived basement topography; (ii) a Curie isotherm assumed to be between 7 km and 10 km; (iii) assuming induced magnetization only; (iv) the available geological and borehole information. The magnetic anomalies were interpreted successfully using the gravity‐derived basement/sedimentary interface as the top of the magnetic bodies (i.e. the magnetic modelling supports the gravity basement topography). An elongated N–S to NW–SE trending highly magnetized body running from south to north along the basin is observed to the west of the basin. This magnetic anomaly has no gravity signature. Such a feature can be interpreted as an intrusive body emplaced along a fault running through the Laguna Salada Basin. Treatment of the gravity and magnetic information (and of their horizontal gradients) with satellite image processing techniques highlighted lineaments on the basement gravity topography correlating with mapped faults. Based on all this information, we derived detailed geological models along four selected profiles to simulate numerically the heat and fluid flow in the basin. We used a finite‐difference scheme to solve the coupled Darcy and Fourier differential equations. According to our results, we have fluid flow in the sedimentary layers and a redistribution of heat flow from the basin axis toward its rims (Sierra de Juárez and Sierra Cucapah). Our model temperatures agree within an error of 4% with the observed temperature profiles measured at boreholes. Our heat‐flow determinations agree within an error of ±15% with extrapolated observations. The numerical and chemical analyses support the hypothesis of fluid circulation between the clay–lutite layer and the fractured granitic basement. Thermal modelling shows low heat‐flow values along the Laguna Salada Basin. Deep fluid circulation patterns were observed that redistribute such flow at depth. Two patterns were distinguished. One displays the heat flow increasing from the basin axis towards its borders (temperature increase of 20°C). The second pattern shows an increasing heat flow from south to north of the basin. Such behaviour is confirmed by the temperature measurements in the thermometric boreholes.  相似文献   

20.
A method is presented to evaluate ground water residence time in a zero‐valent iron (ZVI) permeable reactive barrier (PRB) using radon‐222 (222Rn) as a radioactive tracer. Residence time is a useful indicator of PRB hydraulic performance, with application to estimating the volumetric rate of ground water flow through a PRB, identifying flow heterogeneity, and characterizing flow conditions over time as a PRB matures. The tracer method relies on monitoring the decay of naturally occurring aqueous 222Rn as ground water flows through a PRB. Application of the method at a PRB site near Monticello, Utah, shows that after 8 years of operation, residence times in the ZVI range from 80 to 486 h and correlate well with chemical parameters (pH, Ca, SO4, and Fe) that indicate the relative residence time. Residence times in this case study are determined directly from the first‐order decay equation because we show no significant emanation of 222Rn within the PRB and no measurable loss of 222Rn other than by radioactive decay.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号