首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The effects of higher modes and torsion have a significant impact on the seismic responses of asymmetric-plan tall buildings.A consecutive modal pushover(CMP) procedure is one of the pushover methods that have been developed to consider these effects.The aim of this paper is to modify the(CMP) analysis procedure to estimate the seismic demands of one-way asymmetric-plan tall buildings with dual systems.An analysis of 10-,15-and 20-story asymmetric-plan buildings is carried out,and the results from the modified consecutive modal pushover(MCMP) procedure are compared with those obtained from the modal pushover analysis(MPA) procedure and the nonlinear time history analysis(NLTHA).The MCMP estimates of the seismic demands of one-way asymmetric-plan buildings demonstrate a reasonable accuracy,compared to the results obtained from the NLTHA.Furthermore,the accuracy of the MCMP procedure in the prediction of plastic hinge rotations is better than the MPA procedure.The new pushover procedure is also more accurate than the FEMA load distribution and the MPA procedure.  相似文献   

2.
Performance based design becomes an effective method for estimating seismic demands of buildings. In asymmetric plan tall building the effects of higher modes and torsion are crucial. The consecutive modal pushover (CMP) procedure is one of the procedures that consider these effects. Also in previous studies the influence of soil-structure interaction (SSI) in pushover analysis is ignored. In this paper the CMP procedure is modified for one-way asymmetric plan mid and high-rise buildings considering SSI. The extended CMP (ECMP) procedure is proposed in order to overcome some limitations of the CMP procedure. In this regard, 10, 15 and 20 story buildings with asymmetric plan are studied considering SSI assuming three different soil conditions. Using nonlinear response history analysis under a set of bidirectional ground motion; the exact responses of these buildings are calculated. Then the ECMP procedure is evaluated by comparing the results of this procedure with nonlinear time history results as an exact solution as well as the modal pushover analysis procedure and FEMA 356 load patterns. The results demonstrate the accuracy of the ECMP procedure.  相似文献   

3.
A new modal pushover procedure is proposed for seismic assessment of asymmetric-plan buildings under bi-directional ground motions. Although the proposed procedure is a multi-mode procedure and the effects of the higher and torsional modes are considered, the simplicity of the pushover procedure is kept and the method requires only a single-run pushover analysis for each direction of excitation. The effects of the frequency content of a specific ground motion and the interaction between modes at each direction are all considered in the single-run pushover analysis. For each direction, the load pattern is derived from the combined modal story shear and torque profiles. The pushover analysis is conducted independently for each direction of motion (x and y), and then the responses due to excitation in each direction are combined using SRSS (Square Roots of Sum of Squares) combination rule. Accuracy of the proposed procedure is evaluated through two low- and medium-rise buildings with 10% two-way eccentricity under different pairs of ground motions. The results show promising accuracy for the proposed method in predicting the peak seismic responses of the sample buildings.  相似文献   

4.
Seismic ground motions induce torsional responses in buildings that can be difficult to predict. To compensate for this, most modern building codes require the consideration of accidental torsion when computing design earthquake forces. This study evaluates the influence of ASCE/SEI 7 accidental torsion seismic design requirements on the performance of 230 archetypical buildings that are designed with and without accidental torsion design provisions, taking building collapse capacity as the performance metric. The test case archetypes include a broad range of heights, gravity load levels, and plan configurations. Results show that the ASCE/SEI 7 accidental torsion provisions lead to significant changes in collapse capacity for buildings that are very torsionally flexible or asymmetric. However, only inconsequential changes in collapse capacity are observed in the buildings that are both torsionally stiff and regular in plan. Therefore, the study concludes that accidental torsion provisions are not necessary for seismic design of buildings without excessive torsional flexibility or asymmetry. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

5.
A simplified procedure is proposed to predict the largest peak seismic response of an asymmetric building to horizontal bi-directional ground motion, acting at an arbitrary angle of incidence. The main characteristics of the proposed procedure is as follows. (1) The properties of two independent equivalent single-degree-of-freedom models are determined according to the principal direction of the first modal response in each nonlinear stage, rather than according to the fixed axis based on the mode shape in the elastic stage; the principal direction of the first modal response in each nonlinear stage is determined based on pushover analysis results. (2) The bi-directional horizontal seismic input is simulated as identical spectra of the two horizontal components, and the contribution of each modal response is directly estimated based on the unidirectional response in the principal direction of each. (3) The drift demand at each frame is determined based on four pushover analyses considering the combination of bi-directional excitations. In the numerical example, nonlinear time-history analyses of six four-story torsionally stiff (TS) asymmetric buildings are carried out considering various directions of seismic inputs, and these results are compared with the predicted results. The results show that the proposed procedure satisfactorily predicts the largest peak response displacement at the flexible-side frame of a TS asymmetric building.  相似文献   

6.
An Erratum has been published for this article in Earthquake Engng. Struct. Dyn. 2004; 33:1429. Based on structural dynamics theory, the modal pushover analysis (MPA) procedure retains the conceptual simplicity of current procedures with invariant force distribution, now common in structural engineering practice. The MPA procedure for estimating seismic demands is extended to unsymmetric‐plan buildings. In the MPA procedure, the seismic demand due to individual terms in the modal expansion of the effective earthquake forces is determined by non‐linear static analysis using the inertia force distribution for each mode, which for unsymmetric buildings includes two lateral forces and torque at each floor level. These ‘modal’ demands due to the first few terms of the modal expansion are then combined by the CQC rule to obtain an estimate of the total seismic demand for inelastic systems. When applied to elastic systems, the MPA procedure is equivalent to standard response spectrum analysis (RSA). The MPA estimates of seismic demand for torsionally‐stiff and torsionally‐flexible unsymmetric systems are shown to be similarly accurate as they are for the symmetric building; however, the results deteriorate for a torsionally‐similarly‐stiff unsymmetric‐plan system and the ground motion considered because (a) elastic modes are strongly coupled, and (b) roof displacement is underestimated by the CQC modal combination rule (which would also limit accuracy of RSA for linearly elastic systems). Copyright © 2004 John Wiley & Sons, Ltd.  相似文献   

7.
The elastic and inelastic seismic response of plan‐asymmetric regular multi‐storey steel‐frame buildings has been investigated under bi‐directional horizontal ground motions. Symmetric variants of these buildings were designed according to Eurocodes 3 and 8. Asymmetric buildings were created by assuming a mass eccentricity in each of the two principal directions. The torsional response in the elastic and inelastic range is qualitatively similar with the exception of the stiff edge in the strong direction of torsionally stiff buildings and the stiff edge in the weak direction of torsionally flexible buildings. The response is influenced by the intensity of ground motion, i.e. by the magnitude of plastic deformation. In the limiting case of very strong ground motion, the behaviour of initially torsionally stiff and initially torsionally flexible buildings may become qualitatively similar. A decrease in stiffness due to plastic deformations in one direction may substantially influence the behaviour in the orthogonal direction. The response strongly depends on the detailed characteristics of the ground motion. On average, torsional effects are reduced with increasing plastic deformations, unless the plastic deformations are small. Taking into account also the dispersion of results which is generally larger in the inelastic range than in the elastic one, it can be concluded that (a) the amplification of displacements determined by the elastic analysis can be used as a rough estimate also in the inelastic range and (b) any favourable torsional effect on the stiff side of torsionally stiff buildings, which may arise from elastic analysis, may disappear in the inelastic range. The conclusions are limited to fairly regular buildings and subject to further investigations. Copyright © 2005 John Wiley & Sons, Ltd.  相似文献   

8.
This paper evaluates the inelastic seismic response of torsionally unbalanced structural systems with strength distributed using elastic response spectrum analysis. The structural model is a single mass torsionally unbalanced system with lateral load resisting elements spanning in two principal directions. The element strength is distributed based on elastic response spectrum analysis and three different approaches to incorporate accidental torsion are considered: (a) without incorporating accidental torsion; (b) by applying static floor torques; (c) by shifting the location of the centre of mass. The seismic input is bidirectionally applied at the base of the model. It is shown that the inelastic responses depend strongly on the torsional stiffness of the system. For a torsionally stiff system, the torsional response leads to a decrease in the stiff edge displacement; however, for a torsionally flexible system, it tends to increase the stiff edge displacement. Using response spectrum analysis without including accidental torsion may lead to excessive additional ductility demand on the stiff edge element. With accidental torsion effect incorporated, the response spectrum analysis will give a strength distribution such that there will be no excessive additional ductility demands on the lateral load resisting elements.  相似文献   

9.
A parametric study is carried out to evaluate the seismic displacements at the flexible edge of torsionally unbalanced (TU) structural systems. Guidelines are provided to estimate these displacements so that they can be incorporated in the formulation of the displacement-based seismic design approach for the design of TU buildings. The ability of three code procedures to estimate the flexible-edge displacement is examined to show that not all procedures lead to conservative estimates. Finally, it is shown that elastic spectrum analysis incorporating accidental torsion effect is a viable means to estimate the flexible-edge displacements.  相似文献   

10.
In this study a new method for nonlinear static analysis based on the relative displacements of stories is proposed that is able to be implemented in a single stage analysis and considers the effects of an arbitrary number of higher modes. The method is called the extended drift pushover analysis procedure (EDPA). To define the lateral load pattern, values of the relative displacements of stories are calculated using the elastic modal analysis and the modal combination factors introduced. For determining the combination factors, six different approaches are examined. Buildings evaluated in this study consist of four special steel moment-resisting frames with 10–30 stories. Responses including relative displacements of stories, story shear forces and rotation of plastic hinges in each story are calculated using the proposed approaches in addition to modal pushover analysis and nonlinear dynamic time history analyses. The nonlinear dynamic analysis is implemented using ten consistent earthquake records that have been scaled with regard to ASCE7-10. Distribution of response errors of story shears and plastic hinge rotations show that a major part of error corresponds to the second half of the buildings studied. Thus, the mentioned responses are corrected systematically. The final results of this study show that implementing the EDPA procedure using the third approach of this research is able to effectively overcome the limitations of both the traditional and the modal pushover analyses methods and predict the seismic demands of tall buildings with good accuracy.  相似文献   

11.
Static torsional provisions in most seismic codes require that the lateral force at each floor level be applied at some distance from the reference centre at that floor. However, codes do not specify how to determine the locations of these centres. As a result, several different definitions of the reference centres are being used to implement the code analysis. This investigation examined how the results using various reference centres differ and which of these centres would lead to results that are in agreement with those of dynamic analysis. For this purpose three different buildings ranging form torsionally stiff to torsionally flexible were analysed. It was shown that for the class of buildings studied in this investigation that although the locations of the reference centres were quite different, the results were very similar and nearly independent of the reference centre. Comparison of results calculated from static code equivalent lateral force procedures and results from dynamic response spectrum analyses showed that the static code procedures led to design forces very close (flexible wall) or slightly conservative (stiff wall) when compared to the dynamic analysis for the torsionally stiff building. However, the static code procedures significantly underestimated the design forces of the stiff walls and significantly overestimated the design forces of the flexible walls for the torsionally flexible buildings. © 1998 John Wiley & Sons, Ltd.  相似文献   

12.
This investigation is concerned with accidental torsion in buildings resulting from rotational excitation (about a vertical axis) of the building foundations as a result of spatially non-uniform ground motions. Because of this accidental torsion, the displacements and deformations in the structural elements of the building are likely to increase. This increase in response is evaluated using actual base rotational excitations derived from ground motions recorded at the base of 30 buildings during recent California earthquakes. Accidental torsion has the effect of increasing the building displacements, in the mean, by less than 5 per cent for systems that are torsionally stiff or have lateral vibration periods longer than half a second. On the other hand, short period (less than half a second) and torsionally flexible systems may experience significant increases in response due to accidental torsion. Since the dependence between this increase in response and the system parameters is complex, two simplified methods are developed for conveniently estimating this effect of accidental torsion. They are the ‘accidental eccentricity’ and the ‘response spectrum’ method. The computed accidental eccentricities are much smaller than the typical code values, 0.05bb or 0.1b, except for buildings with very long plan dimensions (b ≥ 50 m). Alternatively, by using the response spectrum method the increase in response can be estimated by computing the peak response to each base motion independently and combining the peak values using the SRSS rule.  相似文献   

13.
Recently, a design modification has been proposed for eccentric, torsionally stiff, braced steel buildings, designed according to the current Eurocodes 3 and 8, that improves noticeably their inelastic response under the action of design level earthquakes. The improvement consists in a more uniform distribution of ductility demands throughout the building. In the present paper, a similar, though differently derived, modification is applied to torsionally flexible eccentric buildings and their response is again evaluated under pairs of design earthquake motions. A substantial improvement of their inelastic response is also observed, similar to what had been obtained for torsionally stiff buildings. The new approach is also tested with torsionally stiff buildings and leads to similarly satisfactory results. Thus it may be recommended for general application.  相似文献   

14.
An attempt has been made to explore the general trends in the seismic response of plan‐asymmetric structures without any restrictions imposed by a particular code. Systems with structural elements in both orthogonal directions under bi‐directional excitation were studied. Idealized single‐storey models with bi‐axial eccentricity were employed. The systems were torsionally stiff and, in the majority of cases, mass‐eccentric. The main findings are: in general, inelastic torsional response is qualitatively similar to elastic torsional response. Quantitatively, the torsional effect on the flexible side, expressed as an increase of displacements due to torsion, decreases slightly with increasing plastic deformation, unless the plastic deformations are small. The response on the stiff side generally strongly depends on the effect of several modes of vibration and on the influence of the ground motion in the transverse direction. These influences depend on the structural and ground motion characteristics in both directions. Reduction of displacements due to torsion, typical for elastic torsionally stiff structures, usually decreases with increasing plastic deformations. As an additional effect of large plastic deformations, a flattening of the displacement envelopes in the horizontal plane usually occurs, indicating that torsional effects in the inelastic range are generally smaller than in the elastic range. The dispersion of the results of inelastic torsional response analysis is generally larger than that of elastic analysis. Copyright © 2005 John Wiley & Sons, Ltd.  相似文献   

15.
本文主要研究如何通过合理设计来提高高层钢结构的整体抗震能力。首先,给出了高层钢结构的非线性计算模型;其次,建立了高层钢结构在强地震动作用下的倒塌失效模式的极限状态判别准则;然后,通过模态pushover分析,研究了高层钢结构在水平地震作用下的损伤规律;最后,重点研究了高层钢结构的整体抗震能力的提高方法,提出了均匀损伤的设计方法,该方法通过消除结构的薄弱层,来达到提高高层钢结构的整体抗震能力的目的。通过对两栋20层的高层钢框架结构进行极限时程分析和极限pushover分析,验证了文中提出的均匀损伤的设计方法的可行性。本文的工作可为高层钢结构的抗地震倒塌设计提供参考依据。  相似文献   

16.
The increasing popularity of simplified nonlinear methods in seismic design has recently led to many proposals for procedures aimed at extending pushover analysis to plan asymmetric structures. In terms of practical applications, one particularly promising approach is based on combining pushover analysis of a 3D structural model with the results of linear (modal) dynamic analysis. The effectiveness of such procedure, however, is contingent on one fundamental requirement: the elastic prediction of the envelope of lateral displacements must be conservative with respect to the actual inelastic one. This paper aims at verifying the above assumption through an extensive parametric analysis conducted with simplified single‐storey models. The main structural parameters influencing torsional response in the elastic and inelastic range of behaviour are varied, while devoting special attention to the system stiffness eccentricity and radius. The analysis clarifies the main features of inelastic torsional response of different types of building structures; in this manner, it is found that the above‐mentioned method is generally suitable for structures characterized by moderate to large torsional stiffness, whereas it cannot be recommended for extremely torsionally stiff structures, as their inelastic torsional response almost always exceeds the elastic one. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

17.
The modal pushover analysis (MPA) procedure, presently restricted to one horizontal component of ground motion, is extended to three‐dimensional analysis of buildings—symmetric or unsymmetric in plan—subjected to two horizontal components of ground motion, simultaneously. Also presented is a variant of this method, called the practical modal pushover analysis (PMPA) procedure, which estimates seismic demands directly from the earthquake response (or design) spectrum. Its accuracy in estimating seismic demands for very tall buildings is evaluated, demonstrating that for nonlinear systems this procedure is almost as accurate as the response spectrum analysis procedure is for linear systems. Thus, for practical applications, the PMPA procedure offers an attractive alternative whereby seismic demands can be estimated directly from the (elastic) design spectrum, thus avoiding the complications of selecting and scaling ground motions for nonlinear response history analysis. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

18.
The effects of horizontal components of ground motion on the linear response of torsionally stiff and torsionally flexible systems, on soft and firm soil conditions, are examined. A one‐story, two‐way asymmetric structural system is used, subjected to uncorrelated ground motion components along their principal directions. Spectral densities for ground accelerations in firm and soft soils are modeled based on recorded data from large intensity Mexican earthquakes. It is shown that for firm soils, in general, these effects are important in the case of torsionally flexible systems that are stiff under translation, or for torsionally stiff systems that are flexible in translation. The percentage combination rules usually specified in seismic design codes are assessed against the dynamic response. Such combination rules can result in overly conservative design forces or underestimated design forces, particularly for torsionally flexible structures. Given the relative magnitude of the response to each ground motion component, it was found that using different percentage values in the combination rules has no significant effect on improving the estimation of the total response. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

19.
The paper investigates the influence of design procedures on the seismic response of multi-storey asymmetric buildings. To this end, some structures are designed according to methods based on either static or modal analysis, with or without design eccentricities. The seismic response of these systems is determined by means of inelastic dynamic analyses and the design is thoroughly examined in order to explain the results of the dynamic analyses. Attention is basically focused on the ability of design methods to prevent asymmetric buildings from experiencing ductility demands much larger than those of the corresponding torsionally balanced systems. Numerical analyses underline that while design procedures based on either static or modal analysis are suitable for the design of torsionally rigid structures only those based on modal analysis lead to the satisfactory performance of torsionally flexible buildings. Furthermore, the study highlights the qualities of a design method proposed by the Authors. Its application does not require any explicit calculation of design eccentricities and leads to proper seismic response of both torsionally rigid and flexible asymmetric buildings.  相似文献   

20.
The reliability of a Pseudodynamic (PsD) test depends primarily on the accuracy of the control system. Difficulties arise mainly when the method is applied to very stiff or very heavy structures or to structures with a high number of Degrees of Freedom (DoFs). This paper describes the bi-directional PsD testing of a full-size three-storey building. The tested specimen is a composite structure with plan dimensions of 12×16 m and height of 9·5 m, made of steel columns and beams combined with composite reinforced concrete slabs. The PsD test included the application of two uncorrelated accelerograms along the horizontal directions X and Y. Since the structure was not symmetric about the Y-axis, the possibility of torsion was considered by taking into account both horizontal displacements and the yaw rotation at every floor. Three displacement-controlled hydraulic actuators were thus used at each floor to impose these three DoFs while a fourth actuator with special control strategy was added to optimize the distribution of loads among the pistons. The validity of the testing methodology was verified by performing also a dynamic random burst test on the specimen which was afterwards pseudodynamically reproduced. Copyright © 1999 John Wiley & Sons, Ltd.  相似文献   