首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 328 毫秒
1.
Vapor intrusion (VI) occurs when volatile contaminants in the subsurface migrate through the vadose zone into overlying buildings. The 2015 U.S. EPA petroleum VI guidance recommends that additional investigation of the VI risk from gasoline hydrocarbons at the underground storage tank (UST) sites is not necessary where the vertical distance between a building and a vapor source exceeds a recommended vertical screening distance. However, due to the lack of soil-gas data on the attenuation of ethylene dibromide (EDB), additional VI investigations to evaluate VI risk from EDB are recommended at UST sites with leaded gasoline releases containing EDB. We analyzed soil-gas and groundwater concentrations of EDB from eight petroleum UST sites using a new analytical method with soil-gas detection limit <0.16 μg/m3 EDB (VI screening level at the 10−6 risk level). The analysis included (1) assessing the frequency of EDB detections ≤0.16 μg/m3 at various vertical separation distances and (2) predicting vertical screening distances for EDB using the U.S. EPA PVIScreen model for different soil types in the vadose zone above dissolved-phase and LNAPL sources. Ranges of estimated aerobic biodegradation rate constants for EDB, air exchange rates for residential buildings, and source vapor concentrations for other constituents were combined with conservative estimates of EDB source concentrations as model inputs. Concentrations of EDB in soil-gas indicated that the U.S. EPA recommended vertical screening distances are protective of VI risk from EDB. Conversely, vertical screening distances predicted by modeling were >6 ft (1.8 m) for sites with sand and loam soil above dissolved phase sources and >15 ft (4.6 m) for sites with sand soil above LNAPL sources. This predicted dependence on the vapor source type and soil type in the vadose zone highlights the importance of soil characterization for VI screening at sites with EDB sources.  相似文献   

2.
Vapor intrusion (VI) involves migration of volatile contaminants from subsurface through unsaturated soil into overlying buildings. In 2015, the US EPA recommended an approach for screening VI risks associated with gasoline releases from underground storage tank (UST) sites. Additional assessment of the VI risk from petroleum hydrocarbons was deemed unnecessary for buildings separated from vapor sources by more than recommended vertical screening distances. However, these vertical screening distances did not apply to potential VI risks associated with releases of former leaded gasoline containing 1,2-dichloroethane (1,2-DCA), because of a lack of empirical data on the attenuation of 1,2-DCA in soil gas. This study empirically evaluated 144 paired measurements of 1,2-DCA concentrations in soil gas and groundwater collected at 47 petroleum UST sites combined with BioVapor modeling. This included (1) assessing the frequency of 1,2-DCA detections in soil gas below 10−6 risk-based screening levels at different vertical separation distances and (2) comparing the US EPA recommended vertical screening distances with those predicted by BioVapor modeling. Vertical screening distances were predicted for different soil types using aerobic biodegradation rate constants estimated from the measured soil-gas data combined with conservative estimates of source concentrations. The modeling indicates that the vertical screening distance of 6 feet (1.8 m) recommended for dissolved-phase sources is applicable for 1,2-DCA below certain threshold concentrations in groundwater, while 15 feet (4.6 m) recommended for light nonaqueous phase liquid (LNAPL) sources is applicable for sites with clay and loam soils in the vadose zone, but not sand, if 1,2-DCA concentrations in groundwater exceed 150 μg/L. This dependence of the predicted vertical screening distances on soil type places added emphasis on proper soil characterization for VI screening at sites with 1,2-DCA sources. The soil-gas data suggests that a vertical screening distance of 15 feet (4.6 m) is necessary for both dissolved-phase and LNAPL sources.  相似文献   

3.
Groundwater monitoring wells are present at most hydrocarbon release sites that are being assessed for cleanup. If screened across the vadose zone, these wells provide an opportunity to collect vapor samples that can be used in the evaluation of vapor movement and biodegradation processes occurring at such sites. This paper presents a low purge volume method (modified after that developed by the U.S. EPA) for sampling vapor from monitoring wells that is easy to implement and can provide an assessment of the soil gas total petroleum hydrocarbon (TPH) and O2 concentrations at the base of the vadose zone. As a result, the small purge method allows for sampling of vapor from monitoring wells to support petroleum vapor intrusion (PVI) risk assessment. The small purge volume method was field tested at the Hal's service station site in Green River, Utah. This site is well‐known for numerous soil gas measurements containing high O2 and high TPH vapor concentrations in the same samples which is inconsistent with well‐accepted biodegradation models for the vapor pathway. Using the low purge volume method, monitoring wells were sampled over, upgradient, and downgradient of the light nonaqueous phase liquid (LNAPL) footprint. Results from our testing at Hal's show that vapor from monitoring wells over LNAPL contained very low O2 and high TPH concentrations. In contrast, vapor from monitoring wells not over LNAPL contained high O2 and low TPH concentrations. The results of this study show that a low purge volume method is consistent with biodegradation models especially for sampling at sites where low permeability soils exist in and around a LNAPL source zone.  相似文献   

4.
Detailed site investigations to assess potential inhalation exposure and risk to human health associated with the migration of petroleum hydrocarbon vapors from the subsurface to indoor air are frequently undertaken at leaking underground storage tank (UST) sites, yet documented occurrences of petroleum vapor intrusion are extremely rare. Additional assessments are largely driven by low screening‐level concentrations derived from vapor transport modeling that does not consider biodegradation. To address this issue, screening criteria were developed from soil‐gas measurements at hundreds of petroleum UST sites spanning a range of environmental conditions, geographic regions, and a 16‐year time period (1995 to 2011). The data were evaluated to define vertical separation (screening) distances from the source, beyond which, the potential for vapor intrusion can be considered negligible. The screening distances were derived explicitly from benzene data using specified soil‐gas screening levels of 30, 50, and 100 µg/m3 and nonparametric Kaplan‐Meier statistics. Results indicate that more than 95% of benzene concentrations in soil gas are ≤30 µg/m3 at any distance above a dissolved‐phase hydrocarbon source. Dissolved‐phase petroleum hydrocarbon sources are therefore unlikely to pose a risk for vapor intrusion unless groundwater (including capillary fringe) comes in contact with a building foundation. For light nonaqueous‐phase liquid (LNAPL) hydrocarbon sources, more than 95% of benzene concentrations in soil gas are ≤30 µg/m3 for vertical screening distances of 13 ft (4 m) or greater. The screening distances derived from this analysis are markedly different from 30 to 100 ft (10 to 30 m) vertical distances commonly found cited in regulatory guidance, even with specific allowances to account for uncertainty in the hydrocarbon source depth or location. Consideration of these screening distances in vapor intrusion guidance would help eliminate unnecessary site characterization at petroleum UST sites and allow more effective and sustainable use of limited resources.  相似文献   

5.
The diffusion of 2,2,4-trimethylpentane (TMP) and 2,2,5-trimethylhexane (TMH) vapors put of residually contaminated sandy soil from the U.S. Environmental Protection Agency (EPA) field research site at Traverse City, Michigan, was measured and modeled. The headspace of an intact core sleeve sample was swept with nitrogen gas to simulate the diffusive release of hydrocarbon vapors from residual aviation gasoline in and immediately above the capillary fringe to a soil-venting air flow in the unsaturated zone. The resulting steady-state profile was modeled using existing diffusivity and air porosity estimates in a balance of diffusive flux and a first order source term. The source strength, which was calibrated with the observed flux of 2,2,4-TMP leaving the sleeve, varied with the residual gasoline remaining in the core, but was independent of the headspace sweep flow rate. This finding suggested that lower soil-venting air flow rates were in principle as effective as higher air flow rates in venting LNAPL vapors from contaminated soils. The saturated vapor concentration ratio of 2,2,4-TMP to 2,2,5-TMH decreased from 6.6 to 3.5 over the duration of the experiments in an expression of distillation effects. The vertical profile model was tested against sample port data in four separate experiments for both species, yielding mean errors ranging from 0 to—24 percent in magnitude.  相似文献   

6.
A field screening method was developed for rapid measurement of benzene and gasoline range total petroleum hydrocarbons (TPHg) concentrations in groundwater. The method is based on collecting photoionization detector (PID) measurements from vapor samples. The vapor samples are collected by bubbling air through groundwater samples (air sparging) with a constant volume, temperature and sparging rate. The level of accuracy, sensitivity, precision, and statistical significance of the estimated concentrations, derived from the screening method, are comparable to conventional laboratory analytical results at concentrations equal to or greater than 150 µg/L for benzene and greater than 50 µg/L for TPHg. The method's concentration estimations can assist in making real‐time decisions regarding location of dissolved plumes and light nonaqueous phase liquid (LNAPL) source zones at many fuel release sites. The screening method was tested in the laboratory and in the field with 208 and 107 samples, respectively. The study concludes that the screening method can be used as a tool to aid in completing a site conceptual model as well as analyzing groundwater from monitoring wells.  相似文献   

7.
An estimation of the volume of light nonaqueous phase liquids (LNAPL) is often required during site assessment, remedial design, or litigation. LNAPL volume can be estimated by a strictly empirical approach whereby core samples, distributed throughout the vertical and lateral extent of LNAPL, are analyzed for LNAPL content, and these data are then integrated to compute a volume. Alternatively, if the LNAPL has obtained vertical equilibrium, the thickness of LNAPL in monitoring wells can be used to calculate of LNAPL in monitoring wells can be used to calculate LNAPL volume at the well locations if appropriate soil and LNAPL properties can be estimated.
A method is described for estimating key soil and LNAPL properties by nonlinear regression of vertical profiles of LNAPL saturation. The methods is relatively fast, cost effective, and amenable to quantitative analysis of uncertainty. Optionally, the method allows statistical determination of best-fit values for the Van Genuchten capillary parameters (n, αoil-water and αoil-air), residual water saturation and ANAPL density. The sensitivity of the method was investigated by fitting field LNAPL saturation profiles and then determining the variation in misfit (mean square residual) as a function of parameter value for each parameter. Using field data from a sandy aquifer, the fitting statistics were found to be highly sensitive to LNAPL density, αoil-water and αoil-air moderately sensitive to the Van Genuchten n value, and weakly sensitive to residual water saturation. The regression analysis also provides information that can be used to estimate uncertainty in the estimated parameters, which can then be used to estimate uncertainty in calculated values of specific volume.  相似文献   

8.
The present study proposes a methodology for predicting the vertical light nonaqueous-phase liquids (LNAPLs) distribution within an aquifer by considering the influence of water table fluctuations. The LNAPL distribution is predicted by combining (1) information on air/LNAPL and LNAPL/water interface elevations with (2) the initial elevation of the water table without LNAPL effect. Data used in the present study were collected during groundwater monitoring undertaken over a period of 4 months at a LNAPL-impacted observation well. In this study, the water table fluctuations raised the free LNAPL in the subsurface to an elevation of 206.63 m, while the lowest elevation was 205.70 m, forming a thickness of 0.93 m of LNAPL-impacted soil. Results show that the apparent LNAPL thickness in the observation well is found to be three times greater than the actual free LNAPL thickness in soil; a finding that agrees with previous studies reporting that apparent LNAPL thickness in observation wells typically exceeds the free LNAPL thickness within soil by a factor estimated to range between 2 and 10. The present study provides insights concerning the transient variation of LNAPL distribution within the subsurface and highlights the capability of the proposed methodology to mathematically predict the actual LNAPL thickness in the subsurface, without the need to conduct laborious field tests. Practitioners can use the proposed methodology to determine by how much the water table should be lowered, through pumping, to isolate the LNAPL-impacted soil within the unsaturated zone, which can then be subjected to in situ vadose zone remedial treatment.  相似文献   

9.
The objective of this study was to investigate whether 222Rn in groundwater can be used as a tracer for light non‐aqueous phase liquid (LNAPL) quantification at a field site treated by dual‐phase LNAPL removal. After the break of a pipeline, 5 ha of soil in the nature reserve Coussouls de Crau in southern France was contaminated by 5100 m3 of crude oil. Part of this oil seeped into the underlying gravel aquifer and formed a floating oil body of about 3.9 ha. The remediation consists of plume management by hydraulic groundwater barriers and LNAPL extraction in the source zone. 222Rn measurements were performed in 21 wells in and outside the source zone during 15 months. In uncontaminated groundwater, the radon activity was relatively constant and remained always >11 Bq/L. The variability of radon activity measurements in wells affected by the pump‐and‐skim system was consistent with the measurements in wells that were not impacted by the system. The mean activities in wells in the source zone were, in general, significantly lower than in wells upgradient of the source zone, owing to partitioning of 222Rn into the oil phase. The lowest activities were found in zones with high non‐aqueous phase liquid (NAPL) recovery. LNAPL saturations around each recovery well were furthermore calculated during a period of high groundwater level, using a laboratory‐determined crude oil–water partitioning coefficient of 38.5 ± 2.9. This yielded an estimated volume of residual crude oil of 309 ± 93 m3 below the capillary fringe. We find that 222Rn is a useful and cheap groundwater tracer for finding zones of good LNAPL recovery in an aquifer treated by dual‐phase LNAPL removal, but that quantification of NAPL saturation using Rn is highly uncertain.  相似文献   

10.
A detailed seasonal study of soil vapor intrusion at a cold climate site with average yearly temperature of 1.9 °C was conducted at a house with a crawlspace that overlay a shallow dissolved‐phase petroleum hydrocarbon (gasoline) plume in North Battleford, Saskatchewan, Canada. This research was conducted primarily to assess if winter conditions, including snow/frost cover, and cold soil temperatures, influence aerobic biodegradation of petroleum vapors in soil and the potential for vapor intrusion. Continuous time‐series data for oxygen, pressure differentials, soil temperature, soil moisture, and weather conditions were collected from a high‐resolution monitoring network. Seasonal monitoring of groundwater, soil vapor, crawlspace air, and indoor air was also undertaken. Petroleum hydrocarbon vapor attenuation and biodegradation rates were not significantly reduced during low temperature winter months and there was no evidence for a significant capping effect of snow or frost cover that would limit oxygen ingress from the atmosphere. In the residual light nonaqueous phase liquid (LNAPL) source area adjacent to the house, evidence for biodegradation included rapid attenuation of hydrocarbon vapor concentrations over a vertical interval of approximately 0.9 m, and a corresponding decrease in oxygen to less than 1.5% v/v. In comparison, hydrocarbon vapor concentrations above the dissolved plume and below the house were much lower and decreased sharply within a few tens of centimeters above the groundwater source. Corresponding oxygen concentrations in soil gas were at least 10% v/v. A reactive transport model (MIN3P‐DUSTY) was initially calibrated to data from vertical profiles at the site to obtain biodegradation rates, and then used to simulate the observed soil vapor distribution. The calibrated model indicated that soil vapor transport was dominated by diffusion and aerobic biodegradation, and that crawlspace pressures and soil gas advection had little influence on soil vapor concentrations.  相似文献   

11.
The objective of the present study is the assessment of Jeddah ambient air quality in terms of PM2.5, and the associated lead 7 years after phasing out leaded gasoline in Saudi Arabia. Twenty‐four air samples were collected at four locations throughout Jeddah during the period from December 23, 2008 to April 6, 2009. The collected PM2.5‐samples were analyzed by ICP‐MS for determination of lead. The average atmospheric PM2.5 concentration was 50.8 µg/m3. Atmospheric PM2.5‐concentrations were higher than the 24‐h U.S. National Ambient Air Quality Standards (NAAQS) in 14 sample events. The average lead concentration for all samples was 0.07326 µg/m3. Atmospheric lead concentration was dependent on the sampling location. Concentrations at the two southern locations were higher than at the two northern locations. Southern locations had higher lead concentrations due to very high traffic density, in addition to their proximity to industrial zone. In general, the results of this study show a considerable decrease in atmospheric lead concentration 7 years after phasing out leaded gasoline. The study recommends further studies to accurately determine the current sources of atmospheric lead.  相似文献   

12.
The occurrence of aerobic biodegradation in the vadose zone between a subsurface source and a building foundation can all-but eliminate the risks from methane and petroleum vapor intrusion (PVI). Understanding oxygen availability and the factors that affect it (e.g., building sizes and their distribution) are therefore critical. Uncovered ground surfaces allow oxygen access to the subsurface to actively biodegrade hydrocarbons (inclusive of methane). Buildings can reduce the net flux of oxygen into the subsurface and so reduce degradation rates. Here we determine when PVI and methane risk is negligible and/or extinguished; defined by when oxygen is present across the entire sub-slab region of existing or planned slab-on-ground buildings. We consider all building slab sizes, all depths to vapor sources and the effect of spacings between buildings on the availability of oxygen in the subsurface. The latter becomes critical where buildings are in close proximity or when increased building density is planned. Conservative assumptions enable simple, rapid and confident screening should sites and building designs comply to model assumptions. We do not model the aboveground “building” processes (e.g., air exchange), and assume the slab-on-ground seals the ground surface so that biodegradation of hydrocarbons is minimized under the built structure (i.e., the assessment remains conservative). Two graphs represent the entirety of the outcomes that allow simple screening of hydrocarbon vapors based only on the depth to the source of vapors below ground, the concentration of vapors within the source, the width of the slab-on-ground building, and the gap between buildings; all independent of soil type. Rectangular, square, and circular buildings are considered. Comparison with field sites and example applications are provided, along with a simple 8-step screening guide set in the context of existing guidance on PVI assessment.  相似文献   

13.
Attenuations of the vertical and horizontal response spectra of the 17 October 1989 Loma Prieta, California, earthquake are developed through analyses of the ground motion at 53 sites within a 100 km radius of the source. The analyses are performed on the spectral ordinates for 16 incremental periods ranging from 0.05 to 2.0 sec. The response spectra are modelled empirically for two different site conditions characterized by rock and stiff-soil geologies. Data analysis is performed by the application of a non-linear multivariate regression procedure allowing for distance and site factor as independent variables. Variation of the vertical-to-horizontal (V/H) spectral ratios with wave frequency and distance shows the same behaviour as observed previously in the widely separated geographic regions of northeastern Taiwan and east-central Iran. The predicted ratios at sites underlain by stiff soil are generally higher than the commonly used value of 2/3 at high frequencies ( > 5 Hz) in the near-source region (R < 30 km), but reduce to 1/2 or less at longer periods and farther distances. This behaviour is also observed at rock sites; however, it is somewhat less pronounced. With a faster attenuation of spectral ordinates at higher frequencies, the shape of the response spectrum is found to change with distance. As expected, the spectral attenuation with distance is generally higher for the vertical spectrum than for the horizontal spectrum. The difference is particularly significant at the higher-frequency end of spectrum. Site amplification factors for stiff soil with respect to rock geology varies between 1.17 and 1.72 for horizontal spectrum and 1.01 and 1.81 for vertical spectrum. Spectral amplifications at four sites underlain by soft soil and artificial fill, are also evaluated. This is done by a comparison of the observed spectra with those predicted for rock geology at corresponding distances. As expected, the resulting amplification factors at soft-soil sites show significant increase relative to those at sites underlain by rock.  相似文献   

14.
Petroleum liquids, referred to as light non‐aqueous phase liquids (LNAPLs), are commonly found beneath petroleum facilities. Concerns with LNAPLs include migration into clean soils, migration beyond property boundaries, and discharges to surface water. Single‐well tracer dilution techniques were used to measure LNAPL fluxes through 50 wells at 7 field sites. A hydrophobic tracer was mixed into LNAPL in a well. Intensities of fluorescence associated with the tracer were measured over time using a spectrometer and a fiber optic cable. LNAPL fluxes were estimated using observed changes in the tracer concentrations over time. Measured LNAPL fluxes range from 0.006 to 2.6 m/year with a mean and median of 0.15 and 0.064 m/year, respectively. Measured LNAPL fluxes are two to four orders of magnitude smaller than a common groundwater flux of 30 m/year. Relationships between LNAPL fluxes and possible governing parameters were evaluated. Observed LNAPL fluxes are largely independent of LNAPL thickness in wells. Natural losses of LNAPL through dissolution, evaporation, and subsequent biodegradation, were estimated using a simple mass balance, measured LNAPL fluxes in wells, and an assumed stable LNAPL extent. The mean and median of the calculated loss rates were found to be 24.0 and 5.0 m3/ha/year, respectively. Mean and median losses are similar to values reported by others. Coupling observed LNAPL fluxes to observed rates of natural LNAPL depletion suggests that natural losses of LNAPL may be an important parameter controlling the overall extent of LNAPL bodies.  相似文献   

15.
Behavior of gasoline pools following a denatured ethanol spill   总被引:1,自引:0,他引:1  
In 1999, approximately 72 m3 of denatured fuel-grade ethanol spilled at a bulk fuel terminal that had existing contamination within the subsurface. An unanticipated increase in the measured depth of the light nonaqueous phase liquid (LNAPL) was observed in nearby monitoring wells following the spill. This paper presents results of a laboratory analysis designed to understand the apparent increase in LNAPL mobility at this site. The two-dimensional stainless steel and glass tank allowed visual assessment of the potential effects that the addition of denatured ethanol may have on a site with pre-existing gasoline contamination. Digital images of gasoline and ethanol spill experiments were analyzed for changes in the characteristics of the existing gasoline pool and residual gasoline saturation in the unsaturated zone. Reductions in the surface and interfacial tensions resulted in significant changes in the size, shape, and saturation of the gasoline pool after the addition of ethanol to the system. The final gasoline pool occupied a smaller area and had a higher saturation. In addition, some smearing of the gasoline into the saturated zone occurred as the capillary fringe was depressed.  相似文献   

16.
Vapor intrusion pathway evaluations commonly begin with a comparison of volatile organic chemical (VOC) concentrations in groundwater to generic, or Tier 1, screening levels. These screening levels are typically quite low reflecting both a desired level of conservatism in a generic risk screening process as well as limitations in understanding of physical and chemical processes that impact vapor migration in the subsurface. To study the latter issue, we have collected detailed soil gas and groundwater vertical concentration profiles and evaluated soil characteristics at seven different sites overlying chlorinated solvent contaminant plumes. The goal of the study was to evaluate soil characteristics and their impacts on VOC attenuation from groundwater to deep soil gas (i.e., soil gas in the unsaturated zone within 2 feet of the water table). The study results suggest that generic screening levels can be adjusted by a factor of 100× at sites with fine‐grained soils above the water table, as identified by visual observations or soil air permeability measurements. For these fine‐grained soil sites, the upward‐adjusted screening levels maintain a level of conservatism while potentially eliminating the need for vapor intrusion investigations at sites that may not meet generic screening criteria.  相似文献   

17.
The site characterization and analysis cone penetrometer system (SCAPS), equipped with realtime fluorophore detection capabilities, was used to delineate subsurface contaminant releases in an area where plating shop waste was temporarily stored. Records indicated that various nonaqueous phase liquids (NAPLs) were released at the site. The investigators advanced the SCAPS laser-induced fluorescence (LIF) sensor to depths beneath the water table of the principal water-bearing zone. The water table was located approximately 6 feet (1.8 m) below ground surface (bgs) across the site. Fluorescence, attributed to fuel compounds commingled with chlorinated solvents, was observed at depths ranging from 4.0 to 11.5 feet (1.2 to 3.5 m) bgs. Fluorescence, attributed to naturally occurring organic materials (by process of elimination and spectral characteristics) commingled with chlorinated solvent constituents, was observed at depths ranging from approximately 13 to 40 feet (4.0 to 12.2 m) bgs. Fluorescence responses from compounds confirmed to be commingled with chlorinated solvents indicates that the SCAPS fluorophore detection system is capable of indirectly delineating vadose zone and subaqueous chlorinated solvents and other dense nonaqueous phase liquids (DNAPLs) at contaminant release sites. This confirmation effort represents the first documented account of the successful application of LIF to identify a mixed DNAPL/LNAPL source zone.  相似文献   

18.
In this study, we present a petroleum vapor intrusion (PVI) tool implemented in Microsoft® Excel® using Visual Basic for Applications and integrated within a graphical interface. The latter helps users easily visualize two‐dimensional soil gas concentration profiles and indoor concentrations as a function of site‐specific conditions such as source strength and depth, biodegradation reaction rate constant, soil characteristics and building features. This tool is based on a two‐dimensional explicit analytical model that combines steady‐state diffusion‐dominated vapor transport in a homogeneous soil with a piecewise first‐order aerobic biodegradation model, in which rate is limited by oxygen availability. As recommended in the recently released United States Environmental Protection Agency's final PVI guidance, a sensitivity analysis and a simplified Monte Carlo uncertainty analysis are also included in the spreadsheet.  相似文献   

19.
In 1992, the U.S. Environmental Protection Agency (EPA) proposed risk-based management of hazardous waste. A major component of the proposed rule is the determination of non-site- specific screening concentration levels from waste leachate. Ground water at a downgradient exposure point must not exceed those screening levels, or more stringent requirements would apply.
The screening concentration level is determined with verified models and equations that simulate the transport and attenuation of chemicals as they travel from the source area to the exposure point. A consortium of screening levels is determined in this paper by considering varying physical, chemical, and biological conditions. In addition, a method is developed for multi component leaching from contaminated soils in a landfill to determine the time-dependent behavior of a finite source. Finally, this paper discusses infiltration rate through the clay liner.  相似文献   

20.
The spatial distribution of residual light non-aqueous phase liquid (LNAPL) is an important factor in reactive solute transport modeling studies. There is great uncertainty associated with both the areal limits of LNAPL source zones and smaller scale variability within the areal limits. A statistical approach is proposed to construct a probabilistic model for the spatial distribution of residual NAPL and it is applied to a site characterized by ultra-violet-induced-cone-penetration testing (CPT–UVIF). The uncertainty in areal limits is explicitly addressed by a novel distance function (DF) approach. In modeling the small-scale variability within the areal limits, the CPT–UVIF data are used as primary source of information, while soil texture and distance to water table are treated as secondary data. Two widely used geostatistical techniques are applied for the data integration, namely sequential indicator simulation with locally varying means (SIS–LVM) and Bayesian updating (BU). A close match between the calibrated uncertainty band (UB) and the target probabilities shows the performance of the proposed DF technique in characterization of uncertainty in the areal limits. A cross-validation study also shows that the integration of the secondary data sources substantially improves the prediction of contaminated and uncontaminated locations and that the SIS–LVM algorithm gives a more accurate prediction of residual NAPL contamination. The proposed DF approach is useful in modeling the areal limits of the non-stationary continuous or categorical random variables, and in providing a prior probability map for source zone sizes to be used in Monte Carlo simulations of contaminant transport or Monte Carlo type inverse modeling studies.  相似文献   