1.
The Tongue Creek watershed lies on the south flank of Grand Mesa in western Colorado, USA and is a site with 1.5 km of topographic relief, heat flow of 100 mW/m2, thermal conductivity of 3.3 W m–1 °C–1, hydraulic conductivity of 10-8 m/s, a water table that closely follows surface topography, and groundwater temperatures 3–15°C above mean surface temperatures. These data suggest that convective heat transport by groundwater flow has modified the thermal regime of the site. Steady state three-dimensional numerical simulations of heat flow, groundwater flow, and convective transport were used to model these thermal and hydrological data. The simulations provided estimates for the scale of hydraulic conductivity and bedrock base flow discharge within the watershed. The numerical models show that (1) complex three-dimensional flow systems develop with a range of scales from tens of meters to tens of kilometers; (2) mapped springs are frequently found at locations where contours of hydraulic head indicate strong vertical flow at the water table, and; (3) the distribution of groundwater temperatures in water wells as a function of surface elevation is predicted by the model.  相似文献   

2.

Urban areas are major contributors to the alteration of the local atmospheric and groundwater environment. The impact of such changes on the groundwater thermal regime is documented worldwide by elevated groundwater temperature in city centers with respect to the surrounding rural areas. This study investigates the subsurface urban heat island (SUHI) in the aquifers beneath the Milan city area in northern Italy, and assesses the natural and anthropogenic controls on groundwater temperatures within the urban area by analyzing groundwater head and temperature records acquired in the 2016–2020 period. This analysis demonstrates the occurrence of a SUHI with up to 3 °C intensity and reveals a correlation between the density of building/subsurface infrastructures and the mean annual groundwater temperature. Vertical heat fluxes to the aquifer are strongly related to the depth of the groundwater and the density of surface structures and infrastructures. The heat accumulation in the subsurface is reflected by a constant groundwater warming trend between +0.1 and?+?0.4 °C/year that leads to a gain of 25 MJ/m2 of thermal energy per year in the shallow aquifer inside the SUHI area. Future monitoring of groundwater temperatures, combined with numerical modeling of coupled groundwater flow and heat transport, will be essential to reveal what this trend is controlled by and to make predictions on the lateral and vertical extent of the groundwater SUHI in the study area.

  相似文献   

3.
Structural relief of the pre-Cenozoic basement and groundwater flow have been found to be the two most important factors affecting the heat flow density determinations in the Liaohe Basin. The reason for the significant effect of basement relief upon subsurface temperature and heat flow density patterns is the strong contrast of thermal conductivity between basement rock and the sedimentary cover. Simplified model computations indicate that the heat flow density in the region of basement uplift is 1.35 times greater than that in the region of depressions. Field observations indicate that the temperatures at shallow depths (less than 1200 m) are strongly perturbed by groundwater flow leading to reduced temperatures and geothermal gradients in the Neogene formation. Comparison of observed and calculated gradients reveals that reduced gradients and heat flow density occur in the groundwater recharge area whereas these parameters are enhanced in the discharge area. After taking the perturbing factors into account, a regional heat flow value of 65 ± 9 mW/m2 is obtained.  相似文献   

4.
Studies of hot springs have focused mainly on the properties of fluids and solids. Fewer studies focus on the relationship between the hot springs and groundwater/surface-water environments. The differences in temperature and dissolved solids between hot-spring water and typical surface water and groundwater allow interactions to be traced. Electromagnetic terrain (EMT) conductivity is a nonintrusive technique capable of mapping mixing zones between distinct subsurface waters. These interactions include zones of groundwater/surface-water exchange and groundwater mixing. Herein, hydrogeological techniques are compared with EMT conductivity to trace hot-spring discharge interactions with shallow groundwater and surface water. Potentiometric-surface and water-quality data determined the hydrogeochemistry of two thermally influenced areas in Yellowstone National Park, Wyoming (USA). Data from the sites revealed EMT conductivity contrasts that reflected the infiltration of conductive hot-spring discharge to local groundwater systems. The anomalies reflect higher temperatures and conductivity for Na+–Cl?-rich hydrothermal fluids compared to the receiving groundwater. EMT conductivity results suggested hot springs are fed by conduits largely isolated from shallow groundwater; mixing of waters occurs after hot-spring discharge infiltrates groundwater from the surface and, generally, not by leakage in the subsurface. A model was proposed to explain the growth of sinter mounds.  相似文献   

5.
A review of coupled groundwater and heat transfer theory is followed by an introduction to geothermal measurement techniques. Thereafter, temperature-depth profiles (geotherms) and heat discharge at springs to infer hydraulic parameters and processes are discussed. Several studies included in this review state that minimum permeabilities of approximately 5?×?10?17?<?k min <10?15?m2 are required to observe advective heat transfer and resultant geotherm perturbations. Permeabilities below k min tend to cause heat-conduction-dominated systems, precluding inversion of temperature fields for groundwater flow patterns and constraint of permeabilities other than being <k min. Values of k min depend on the flow-domain aspect-ratio, faults and other heterogeneities, anisotropy of hydraulic and thermal parameters, heat-flow rates, and the water-table shape. However, the k min range is narrow and located toward the lower third of geologic materials, which exhibit permeabilities of 10?21?<?k?<?10?7?m2. Therefore, a wide range of permeabilities can be investigated by analyzing subsurface temperatures or heat discharge at springs. Furthermore, temperature is easy and economical to measure and because thermal material properties vary far less than hydraulic properties, temperature measurements tend to provide better-constrained groundwater flow and permeability estimates. Aside from hydrogeologic insights, constraint of advective/conductive heat transfer can also provide information on magmatic intrusions, metamorphism, ore deposits, climate variability, and geothermal energy.  相似文献   

6.
Geothermal springs are some of the most obvious indicators of the existence of high-temperature geothermal resources in the subsurface. However, geothermal springs can also occur in areas of low average subsurface temperatures, which makes it difficult to assess exploitable zones. To address this problem, this study quantitatively analyzes the conditions associated with the formation of geothermal springs in fault zones, and numerically investigates the implications that outflow temperature and discharge rate from geothermal springs have on the geothermal background in the subsurface. It is concluded that the temperature of geothermal springs in fault zones is mainly controlled by the recharge rate from the country rock and the hydraulic conductivity in the fault damage zone. Importantly, the topography of the fault trace on the land surface plays an important role in determining the thermal temperature. In fault zones with a permeability higher than 1 mD and a lateral recharge rate from the country rock higher than 1 m3/day, convection plays a dominant role in the heat transport rather than thermal conduction. The geothermal springs do not necessarily occur in the place having an abnormal geothermal background (with the temperature at certain depth exceeding the temperature inferred by the global average continental geothermal gradient of 30 °C/km). Assuming a constant temperature (90 °C here, to represent a normal geothermal background in the subsurface at a depth of 3,000 m), the conditions required for the occurrence of geothermal springs were quantitatively determined.  相似文献   

7.
8.
Characterization of a Pleistocene thermal spring in Mozambique   总被引:1,自引:1,他引:0  
A hydrogeological study was conducted with the objective to investigate the only currently known hot spring of Sofala Province in Mozambique with respect to the origin of the water, the discharge, and its chemical composition. Field investigations comprised a general land use survey, mapping of sediment and water temperatures, discharge measurements and on-site water chemistry as well as sampling for further chemical analyses and groundwater dating. Thermal water discharge occurs along a 100 m long NE–SW zone with water temperatures ranging from 42 to 64.5°C. The thermal water is a low-mineralized sodium-chloride-sulfate water enriched in phosphate, fluorine and nickel. The silica geothermometer, the silica concentration of 43 mg/kg and the ratios of Br/Cl and I/Cl of 2.5?×?10–3, suggest that the thermal water stems from approximately 5,000 m depth and had a long residence time with silicate rocks. This points towards Gorongosa Mountain as the water source area. 14C dating suggests a groundwater age of 11,000 years.  相似文献   

9.
A study was conducted to understand the hydrogeological processes dominating in the North 24 Parganas and South 24 Parganas based on representative 39 groundwater samples collected from selected area. The abundance of major ions was in the order of Ca2+ > Na+ > Mg2+ > K+ > Fe2+ for cations and HCO3 ? > PO4 3? > Cl? > SO4 2? > NO3 ? for anions. Piper trilinear diagram was plotted to understand the hydrochemical facies. Most of the samples are of Ca-HCO3 type. Based on conventional graphical plots for (Ca + Mg) vs. (SO4 + HCO3) and (Na + K) vs. Cl, it is interpreted that silicate weathering and ion exchange are the dominant processes within the study area. Previous studies have reported quartz, feldspar, illite, and chlorite clay minerals as the major mineral components obtained by the XRD analysis of sediments. Mineralogical investigations by SEM and EDX of aquifer materials have shown the occurrence of arsenic as coating on mineral grains in the silty clay as well as in the sandy layers. Excessive withdrawal of groundwater for irrigation and drinking purposes is responsible for fluctuation of the water table in the West Bengal. Aeration beneath the ground surface caused by fluctuation of the water table may lead to the formation of carbonic acid. Carbonic acid is responsible for the weathering of silicate minerals, and due to the formation of clay as a product of weathering, ion exchange also dominates in the area. These hydrogeological processes may be responsible for the release of arsenic into the groundwater of the study area, which is a part of North 24 Parganas and South 24 Parganas.  相似文献   

10.

Thermal perturbation in the subsurface produced in an open-loop groundwater heat pump (GWHP) plant is a complex transport phenomenon affected by several factors, including the exploited aquifer’s hydrogeological and thermal characteristics, well construction features, and the temporal dynamics of the plant’s groundwater abstraction and reinjection system. Hydraulic conductivity has a major influence on heat transport because plume propagation, which occurs primarily through advection, tends to degrade following conductive heat transport and convection within moving water. Hydraulic conductivity is, in turn, influenced by water reinjection because the dynamic viscosity of groundwater varies with temperature. This paper reports on a computational analysis conducted using FEFLOW software to quantify how the thermal-affected zone (TAZ) is influenced by the variation in dynamic viscosity due to reinjected groundwater in a well-doublet scheme. The modeling results demonstrate non-negligible groundwater dynamic-viscosity variation that affects thermal plume propagation in the aquifer. This influence on TAZ calculation was enhanced for aquifers with high intrinsic permeability and/or substantial temperature differences between abstracted and post-heat-pump-reinjected groundwater.

  相似文献   

11.
The aquifer of the semi-arid Kairouan plain has been exploited for decades to supply the growing irrigated agriculture and the need of drinking water. In parallel, the major hydraulic works drastically changed the natural groundwater recharge processes. The continuous groundwater level drop observed since the 1970s naturally raises the question of groundwater storage sustainability. To date, hydrogeological studies focused on groundwater fluxes, but the total amount of groundwater stored in the aquifer system has never been fully estimated. This is the purpose of the present paper. A complete database of all available geological, hydrogeological and geophysical data was created to build a 3D lithology model. Then, the lithological units were combined with the hydraulic properties to estimate the groundwater storage. Over the 700 km2 of the modelled area, the estimated storage in 2013 was around 18?×?109 m3 (equivalent to 80 times the annual consumption of 2010) with a highly variable spatial distribution. In 45 years (1968–2013), 12% of the amount of groundwater stored in the aquifer has been depleted. According to these results, individual farms will face strong regional disparities for their access to groundwater in the near future.  相似文献   

12.
Aquifer thermal energy storage in urban and industrial areas can lead to an increase in subsurface temperature to 70 °C and more. Besides its impacts on mineral and sorption equilibria and chemical reaction kinetics in an aquifer, temperature sensitively influences microbial activity and thus redox processes, such as sulphate reduction. Microorganism species can only operate within limited temperature ranges and their adaptability to temperature is a crucial point for the assessment of the environmental consequences of subsurface heat storage. Column experiments with aquifer sediment and tap water at 10, 25, 40, and 70 °C showed that under the constant addition of acetate sulphate reduction could be initiated after 26–63 pore volumes exchanged at all temperatures. Fastest initiation of sulphate reduction with the highest reduction rates was found at 40 °C. Maximum rate constants during experimental run-time were 0.56 h?1 at 40 °C and 0.33, 0.36, and 0.25 h?1 at 10 and, 25, and 70 °C, respectively. Hence, microbial activity was enhanced by a temperature increase to 40 °C but was significantly lowered at 70 °C. At 25 °C methane was found in solution, indicating the presence of fermenting organisms; at 10, 40, and 70 °C no methane production was observed. It could be shown that redox processes in an aquifer generally can adapt to temperatures significantly higher than in situ temperature and that the efficiency of the reduction process can be enhanced by temperature increase to a certain limit. Enhancement of sulphate reduction in an aquifer due to temperature increase could also allow enhanced degradation of organic ground water contaminants such as BTEX, where sulphate is an important electron acceptor.  相似文献   

13.
The present study aims to discuss the hydrogeochemical processes in the Aosta Valley region and assess the quality of its groundwater for suitability of drinking and irrigation purposes. One hundred twenty-two samples were collected from the Aosta Valley region in the years 2007 and 2008 (61 per year), and analysed for pH, electrical conductivity, total dissolved solids (TDS), total hardness, major cations and anions. The pH of the samples in both years indicated a near-neutral to alkaline nature of the groundwater. The cation and anion chemistry showed the general ionic abundance as: Ca2+ > Mg2+ > Na+ > K+ and HCO3 ?>SO4 2?>Cl?>NO3 ?>F? in both years. Ca2+-Mg2+-HCO3 ? and Ca2+-Mg2+-Cl?-SO4 2? were the dominant hydrogeochemical facies. The computed saturation indices demonstrated that the groundwater was supersaturated with respect to dolomite and calcite in both years. The groundwater chemistry of the study area was mainly controlled by the dissolution of carbonate, sulphate and silicate minerals, as well as ion exchange processes. A comparison of the groundwater quality in relation to drinking water standards showed that most of the water samples were suitable for drinking and domestic uses. The computed water quality index (WQI) values of the study area groundwater ranged from 24 to 84 in the year 2007 and from 22 to 82 in the year 2008, and all the location fell under the Excellent to Good category. Quality assessment for irrigation uses revealed that the groundwater was good to permissible quality for irrigation; however, locally higher salinity, residual sodium carbonate (RSC) and magnesium hazard (MH) restricted its suitability for irrigation at a few sites. These results will be useful in implementing future measures in groundwater resource management at regional and national level.  相似文献   

14.
Direct push (DP) technologies are typically used for cost-effective geotechnical characterization of unconsolidated soils and sediments. In more recent developments, DP technologies have been used for efficient hydraulic conductivity (K) characterization along vertical profiles with sampling resolutions of up to a few centimetres. Until date, however, only a limited number of studies document high-resolution in situ DP data for three-dimensional conceptual hydrogeological model development and groundwater flow model parameterization. This study demonstrates how DP technologies improve building of a conceptual hydrogeological model. We further evaluate the degree to which the DP-derived hydrogeological parameter K, measured across different spatial scales, improves performance of a regional groundwater flow model. The study area covers an area of ~60 km2 with two overlying, mainly unconsolidated sand aquifers separated by a 5–7 m thick highly heterogeneous clay layer (in north-eastern Belgium). The hydrostratigraphy was obtained from an analysis of cored boreholes and about 265 cone penetration tests (CPTs). The hydrogeological parameter K was derived from a combined analysis of core and CPT data and also from hydraulic direct push tests. A total of 50 three-dimensional realizations of K were generated using a non-stationary multivariate geostatistical approach. To preserve the measured K values in the stochastic realizations, the groundwater model K realizations were conditioned on the borehole and direct push data. Optimization was performed to select the best performing model parameterization out of the 50 realizations. This model outperformed a previously developed reference model with homogeneous K fields for all hydrogeological layers. Comparison of particle tracking simulations, based either on the optimal heterogeneous or reference homogeneous groundwater model flow fields, demonstrate the impact DP-derived subsurface heterogeneity in K can have on groundwater flow and solute transport. We demonstrated that DP technologies, especially when calibrated with site-specific data, provide high-resolution 3D subsurface data for building more reliable conceptual models and increasing groundwater flow model performance.  相似文献   

15.
Groundwater of an aquifer located in the vicinity of a large coal washery near Zarand City, Iran consists of two hydrochemically differing facies, which have been informally designated as groundwater (A) and groundwater (B). Groundwater (A) is native, brackish in composition and is characterized by Na+ > Mg2+ > Ca2+ > K+ and SO4 2? > HCO3 ? > Cl? > NO3 ?. Spearman’s rank correlation coefficient matrices, factor analysis data, and values of chloro-alkaline indices, C ratio and Na+/Cl? molar ratio indicate that in the groundwater (A), the ionic load of Ca2+, Mg2+, Na+, K+, SO4 2? and HCO3 ? is derived essentially from weathering of both carbonates and aluminosilicates and direct cation and reverse cation–anion exchange reactions. Groundwater (B) is the polluted variant of the groundwater (A), brackish to saline in composition, and unlike the groundwater (A), consists of HCO3 ? as the dominant anion. In comparison with the groundwater (A), the groundwater (B) contains higher concentrations of all ions, and its average ionic load (av. = 59.74 me/L) is 1.43 times higher than that of the groundwater (A) (av. = 41.54 me/L). Additional concentrations of Ca2+, Mg2+, K+, SO4 2?, Cl? and HCO3 ? in the groundwater (B) are provided mainly by downward infiltrating water from the coal washery tailings pond and reverse cation–anion exchange reaction between tailings pond water and exchanger of the aquifer matrix during non-conservative mixing process of groundwater (A) and tailings pond water. Certain additional concentrations of Na+, K+ and NO3 ? in the groundwater (B) are provided by other anthropogenic sources. Quality wise, both groundwaters are marginally suitable for cultivation of salt-tolerant crops only.  相似文献   

16.
Major ions and important trace elements in addition to δ18O and δ2H were analysed for 43 groundwater samples sampled from the Al-Batin alluvial fan aquifer, South Iraq. The most dominant ions (with respect to molarity) were: Na+ > Cl? > SO4 2? > Ca2+ > Mg2+ > NO3 ? > HCO3 ?, with total dissolved solids (TDS) averaging 7855 mg/L. High concentrations were found for the trace elements U, Mo, V, B, Sr, and Cr. This study suggests a hydraulic connection exists near the fan apex between the uppermost part of the Al-Batin aquifer and the underlying Dammam aquifer by means of the Abu-Jir fault system. Except for the effects of extensive irrigation, fertilizer use, and poorly maintained sewers, the groundwater chemistry is mainly controlled by geological processes such as dissolution of evaporites and the enrichment of dissolved ions as a result of the high evaporation and low recharge rate. Furthermore, it is shown that the Kuwaiti fuel–oil burning during Gulf War in 1991 contributed to the enrichment of V and Mo in the studied aquifer. The spatial distribution of most ions appears to generally increase from the south-west towards the north-east, in the direction of groundwater flow. The stable isotopes show heavier values in groundwater with a gradually increasing trend in the direction of groundwater flow due to the decreasing depth to groundwater and thus increasing of evaporation from both groundwater or irrigation return water. Additionally, the stable isotope signature suggests that rainfall from sources in the Arabian Gulf and the Arabian Sea is the major source of recharge for the Al-Batin aquifer. Except for two samples of groundwater, all samples were not suitable for potable use according to the WHO standards. Most of the groundwater is suitable for some agricultural purpose and for livestock water supply. Apart from the high salinity, boron represents the most critical element in the groundwater with respect to agricultural purposes.  相似文献   

17.
Information generated from geophysical, geochemical and hydrogeological data has been used in assessing the groundwater resource potential, quality and usability and in mapping flow directions within the shallow subsurface of the Mamfe Embayment, Cross River State, Nigeria. The electrical resistivity technique in which the Schlumberger’s vertical electrical sounding field procedure has been adopted was the geophysical method employed; lithology logs from drilling records, discharge rates, static water level information were the hydrogeological information utilized, while the geochemical techniques involve analyses of water samples. Apparent resistances were measured using different resistivity meters including OYO McOhm (model 2115), ABEM terrameter (SAS300B and SAS1000 models) and IGIS (SSP-ATS-MRP model) with maximum current electrode separation reaching 1 km in some communities. Geological information was used as control in the modelling and interpretation of all geophysical data. The physico-chemical parameters of the water samples from the different water sources in the area were determined using different analytical techniques and in some cases, by in situ direct measurement of some parameters. Measured values of electrical conductivity, static water level, available aquifer discharge information and calculated SAR and %Na were integrated into the geophysical and hydrogeological results. The shallow subsurface of the area is segmented into four hydrogeological provinces [crystalline basement province (CBP), Cross River Plain Province (CRPP), Nkporo-Afikpo Shales Province (NASP) and alluvial/buried river province (ABRP) with localized groundwater flow patterns]. Results indicated that the alluvial (discharge rate of 3.83 L/s), fractured sandstone (discharge rate of 2.43 L/s) and basement (discharge rate of 1.80 L/s) aquifers are more yielding than the aquifers in areas covered with deformed shales (discharge rate of 0.62 L/s) and siltstone aquifers (discharge rate of 0.97 L/s). The aquifer horizons are inhomogeneous and anisotropic with topography and lithology exerting significant influence on groundwater flow direction. However, there appears to be some high yielding aquifers at depths greater than 100 m in the CRPP areas although researches on their distribution are still ongoing. Precipitation is the major source of recharge and the water is enriched with Na+, K+, Ca2+, Mg2+, ${\text{HCO}}_{ 3}^{ - }$ , Cl?, ${\text{SO}}_{ 4}^{2 - }$ and ${\text{NO}}_{ 3}^{ - }$ throughout the year. Graphical analyses of hydrochemical data using Piper and Stiff diagrams show that Ca–(Mg)–CO3–HCO3 is the dominant water facies. Results from EC, SAR and %Na show that the water is fresh and belongs to the good-to-excellent class and is, therefore, suitable for domestic, agricultural and industrial use.  相似文献   

18.
Groundwater is a vital source for domestic and irrigation purposes in the loess area of Northwest China where climate is arid. However, the quality of groundwater in this area is deteriorating due to intensive industrial and agricultural activities, and this has a great adverse impact on human health. In order to better understand the pollution status of groundwater and the health risks to local residents, comprehensive water quality index was applied to assess the quality of drinking water in Yulin City, Northwest China, and sodium adsorption ratio, sodium percentage, residual sodium carbonate and permeability index were used to evaluate the quality of irrigation water. Moreover, the health risks caused by ingestion of groundwater were evaluated using the model proposed by the Ministry of Environmental Protection of the PR China. The results show that all groundwater samples for irrigation will not induce soil salinization, but more than half of them are not suitable for drinking, and Fe, Mn, TH, Mg2+ and NO3–N are the common contaminants which are mainly from natural processes, industrial and agricultural activities. The health risk assessment indicates that children face greater non-carcinogenic risk than adults. The order of contribution of contaminants to non-carcinogenic risk is NO3 ? > As > F? > Fe > Mn > Ba2+ > Cr6+ > Zn > NO2 ?. The average carcinogenic risk of carcinogens (Cr6+ and As) is 1.17 × 10?4 and 1.37 × 10?4 for adults and children, respectively, which surpasses the permissible level (1 × 10?6) stipulated by the Ministry of Environmental Protection of the PR China. Hence, effective measures are highly demanded to manage groundwater pollution and reduce the risks to human health.  相似文献   

19.
Twenty groundwater samples were collected from Enugu metropolis over two seasonal periods in order to characterize the groundwater and to determine its quality for domestic and irrigation purposes. The results show that groundwater of the area is strongly acidic to slightly alkaline in nature and varied from “soft water” to “moderately hard” water type. The major ionic trend is in the order Cl> Na> HCO3 ? > K> Mg2+ > Ca2+ > SO4 2?and Mg2+ > Cl> Na> K> Ca2+ > HCO 3 > SO4 2? in abundance for dry and rainy seasons, respectively. The results also reveal that there is an increase in trend of the ionic concentrations during the dry season, which arises from weathering of the host rocks and anthropogenic activities. Two hydrochemical facies were identified, namely, Na+ –K+ –Cl? –SO4 2?and Ca2+ –Mg2+ –Cl? –SO4 2? , with Na+ –K+ –Cl? –SO4 2? as the dominant facies for the two seasons. Groundwater quality ranges from “very poor water” to “good water” and “water unsuitable for drinking purposes” to “good water” for the dry season and rainy season investigations, respectively. The groundwater is suitable for irrigation purposes for the two seasons.  相似文献   

20.
Understanding the transference of water resources within hydrogeological systems, particularly in coastal aquifers, in which groundwater discharge may occur through multiple pathways (through springs, into rivers and streams, towards the sea, etc.), is crucial for sustainable groundwater use. This research aims to demonstrate the usefulness of the application of conventional recharge assessment methods coupled to isotopic techniques for accurately quantifying the hydrogeological balance and submarine groundwater discharge (SGD) from coastal carbonate aquifers. Sierra Almijara (Southern Spain), a carbonate aquifer formed of Triassic marbles, is considered as representative of Mediterranean coastal karst formations. The use of a multi-method approach has permitted the computation of a wide range of groundwater infiltration rates (17–60%) by means of direct application of hydrometeorological methods (Thornthwaite and Kessler) and spatially distributed information (modified APLIS method). A spatially weighted recharge rate of 42% results from the most coherent information on physiographic and hydrogeological characteristics of the studied system. Natural aquifer discharge and groundwater abstraction have been volumetrically quantified, based on flow and water-level data, while the relevance of SGD was estimated from the spatial analysis of salinity, 222Rn and the short-lived radium isotope 224Ra in coastal seawater. The total mean aquifer discharge (44.9–45.9 hm3 year?1) is in agreement with the average recharged groundwater (44.7 hm3 year?1), given that the system is volumetrically equilibrated during the study period. Besides the groundwater resources assessment, the methodological aspects of this research may be interesting for groundwater management and protection strategies in coastal areas, particularly karst environments.  相似文献   