1.
Chlorinated solvents are one of the most commonly detected groundwater contaminants in industrial areas. Identification of polluters and allocation of contaminant sources are important concerns in the evaluation of complex subsurface contamination with multiple sources. In recent years, compound‐specific isotope analyses (CSIA) have been employed to discriminate among different contaminant sources and to better understand the fate of contaminants in field‐site studies. In this study, the usefulness of dual isotopes (carbon and chlorine) was shown in assessments of groundwater contamination at an industrial complex in Wonju, Korea, where groundwater contamination with chlorinated solvents such as trichloroethene (TCE) and carbon tetrachloride (CT) was observed. In November 2009, the detected TCE concentrations at the study site ranged between nondetected and 10,066 µg/L, and the CT concentrations ranged between nondetected and 985 µg/L. In the upgradient area, TCE and CT metabolites were detected, whereas only TCE metabolites were detected in the downgradient area. The study revealed the presence of separate small but concentrated TCE pockets in the downgradient area, suggesting the possibility of multiple contaminant sources that created multiple comingling plumes. Furthermore, the variation of the isotopic (δ13C and δ37Cl) TCE values between the upgradient and downgradient areas lends support to the idea of multiple contamination sources even in the presence of detectable biodegradation. This case study found it useful to apply a spatial distribution of contaminants coupled with their dual isotopic values for evaluation of the contaminated sites and identification of the presence of multiple sources in the study area.  相似文献   

2.
《水文科学杂志》2013,58(3):524-530
Abstract

Detection efficiencies of alternative groundwater monitoring networks were evaluated in relation to distance to a buffer zone (contaminant migration) boundary. This boundary establishes a distance limit within which contaminant plumes should pass through monitoring wells, located on curvilinear segments (monitoring loci) near a waste storage facility. Alternative strategies allocated monitoring wells to loci at specified distances, measured parallel to groundwater flow, from the downgradient boundaries of a landfill. One approach constrained wells to equal spacing, measured perpendicular to groundwater flow. Compressing well locations 10% closer to the downgradient corner of the landfill rendered alternative monitoring configurations. Computations by a monitoring efficiency model indicated: (a) networks largely maintained detection efficiency for different contaminant migration boundaries; (b) one network most efficiently attained a target detection capability for all contaminant migration boundaries; and (c) compressed networks slightly outperformed equal-spaced counterparts. Compressed networks with more wells along closer monitoring loci best maintained the detection efficiency when shifting the contaminant migration boundary closer to the landfill. Procedures described in this paper may be useful for examining trade-offs between monitoring efficiency and distance limits of contaminant travel at landfills posing potential hazards to underlying groundwater.  相似文献   

3.
The U.S. EPA 2000 Radionuclide Rule established a maximum contaminant level (MCL) for uranium of 30 µg/L. Many small community water supplies are struggling to comply with this new regulation. At one such community, direct push (DP) methods were applied to obtain hydraulic profiling tool (HPT) logs and install small diameter wells in a section of alluvial deposits located along the Platte River. This work was conducted to evaluate potential sources of elevated uranium in the Clarks, Nebraska drinking water supply. HPT logs were used to understand the hydrostratigraphy of a portion of the aquifer and guide placement of small diameter wells at selected depth intervals. Low-flow sampling of the wells provided water quality parameters and samples for analysis to study the distribution of uranium and variations in aquifer chemistry. Contrary to expectations, the aquifer chemistry revealed that uranium was being mobilized under anoxic and reducing conditions. Review of the test well and new public water supply well construction details revealed that filter packs extended significantly above the screened intervals of the wells. These filter packs were providing a conduit for the movement of groundwater with elevated concentrations of uranium into the supply wells and the community drinking water supply. The methods applied and lessons learned here may be useful for the assessment of unconsolidated aquifers for uranium, arsenic, and many other drinking water supply contaminants.  相似文献   

4.
Toxic and carcinogenic effects of arsenic in drinking water continue to impact people throughout the world and arsenic remains common in groundwater at cleanup sites and in areas with natural sources. Advances in groundwater remediation are needed to attain the low concentrations that are protective of human health and the environment. In this article, we present the successful use of a permeable reactive barrier (PRB) utilizing sulfate reduction coupled with zero‐valent iron (ZVI) to remediate the leading edge of a dissolved arsenic plume in a wetland area near Tacoma, Washington. A commercially available product (EHC‐M®, Adventus Americas Inc., Freeport, Illinois) that contains ZVI, organic carbon substrate, and sulfate was injected into a reducing, low‐seepage‐velocity aquifer elevated in dissolved arsenic and iron from a nearby, slag‐containing landfill. Removal effectiveness was strongly correlated with sulfate concentration, and was coincident with temporary redox potential (Eh) reductions, consistent with arsenic removal by iron sulfide precipitation. The PRB demonstrates that induced sulfate reduction and ZVI are capable of attaining a regulatory limit of 5 µg/L total arsenic, capturing of 97% of the arsenic entering the PRB, and sustaining decreased arsenic concentrations for approximately 2 years, suggesting that the technology is appropriate for consideration at other sites with similar hydrogeochemical conditions. The results indicate the importance of delivery and longevity of minimum sulfate concentrations and of maintaining sufficient dissolved organic carbon and/or microscale ZVI to precipitate FeS, a precursor phase to arsenic‐bearing pyrite that may provide a stable, long‐term sink for arsenic.  相似文献   

5.
Ground water samples collected from the Norman Landfill research site in central Oklahoma were analyzed as part of the U.S. Geological Survey (USGS) Toxic Substances Hydrology Program's national reconnaissance of pharmaceuticals and other organic waste water contaminants (OWCs) in ground water. Five sites, four of which are located downgradient of the landfill, were sampled in 2000 and analyzed for 76 OWCs using four research methods developed by the USGS. OWCs were detected in water samples from all of the sites sampled, with 22 of the 76 OWCs being detected at least once. Cholesterol (a plant and animal steroid), was detected at all five sites and was the only compound detected in a well upgradient of the landfill. N,N-diethyltoluamide (DEBT used in insect repellent) and tri(2-chloroethyl) phosphate (fire-retardant) were detected in water samples from all four sites located within the landfill-derived leachate plume. The sites closest to the landfill had more detections and greater concentrations of each of the detected compounds than sites located farther away. Detection of multiple OWCs occurred in the four sites located within the leachate plume, with a minimum of four and a maximum of 17 OWCs detected. Because the landfill was established in the 1920s and closed in 1985, many compounds detected in the leachate plume were likely disposed of decades ago. These results indicate the potential for long-term persistence and transport of some OWCs in ground water.  相似文献   

6.
Implementation of aquifer storage recovery (ASR) for water resource management in Florida is impeded by arsenic mobilization. Arsenic, released by pyrite oxidation during the recharge phase, sometimes results in groundwater concentrations that exceed the 10 µg/L criterion defined in the Safe Drinking Water Act. ASR was proposed as a major storage component for the Comprehensive Everglades Restoration Plan (CERP), in which excess surface water is stored during the wet season, and then distributed during the dry season for ecosystem restoration. To evaluate ASR system performance for CERP goals, three cycle tests were conducted, with extensive water‐quality monitoring in the Upper Floridan Aquifer (UFA) at the Kissimmee River ASR (KRASR) pilot system. During each cycle test, redox evolution from sub‐oxic to sulfate‐reducing conditions occurs in the UFA storage zone, as indicated by decreasing Fe2+/H2S mass ratios. Arsenic, released by pyrite oxidation during recharge, is sequestered during storage and recovery by co‐precipitation with iron sulfide. Mineral saturation indices indicate that amorphous iron oxide (a sorption surface for arsenic) is stable only during oxic and sub‐oxic conditions of the recharge phase, but iron sulfide (which co‐precipitates arsenic) is stable during the sulfate‐reducing conditions of the storage and recovery phases. Resultant arsenic concentrations in recovered water are below the 10 µg/L regulatory criterion during cycle tests 2 and 3. The arsenic sequestration process is appropriate for other ASR systems that recharge treated surface water into a sulfate‐reducing aquifer.  相似文献   

7.
In the upper Midwest, USA, elevated arsenic concentrations in public drinking water systems are associated with the lateral extent of northwest provenance late Wisconsin-aged drift. Twelve percent of public water systems located within the footprint of this drift (212 of 1764) exceed 10 microg/L arsenic, which is the U.S. EPA's drinking water standard. Outside of the footprint, only 2.4% of public water systems (52 of 2182) exceed 10 microg/L arsenic. Both glacial drift aquifers and shallow bedrock aquifers overlain by northwest provenance late Wisconsin-aged sediment are affected by arsenic contamination. Evidence suggests that the distinct physical characteristics of northwest provenance late Wisconsin-aged drift--its fine-grained matrix and entrained organic carbon that fosters biological activity--cause the geochemical conditions necessary to mobilize arsenic via reductive mechanisms such as reductive desorption and reductive dissolution of metal oxides. This study highlights an important and often unrecognized phenomenon: high-arsenic sediment is not necessary to cause arsenic-impacted ground water--when "impacted" is now defined as >10 microg/L. This analysis also demonstrates the scientific and economic value of using existing large but imperfect statewide data sets to observe and characterize regional-scale environmental problems.  相似文献   

8.
Arsenic concentrations can be managed with a relatively simple strategy of grouting instead of completely destroying a selected interval of well. The strategy of selective grouting was investigated in Antelope Valley, California, where groundwater supplies most of the water demand. Naturally occurring arsenic typically exceeds concentrations of 10 µg/L in the water produced from these long-screened wells. The vertical distributions of arsenic concentrations in intervals of the aquifer contributing water to selected supply wells were characterized with depth-dependent water-quality sampling and flow logs. Arsenic primarily entered the lower half of the wells where lacustrine clay deposits and a deeper aquifer occurred. Five wells were modified by grouting from below the top of the lacustrine clay deposits to the bottom of the well, which reduced produced arsenic concentrations to less than 2 µg/L in four of the five wells. Long-term viability of well modification and reduction of specific capacity was assessed for well 4-54 with AnalyzeHOLE, which creates and uses axisymmetric, radial MODFLOW models. Two radial models were calibrated to observed borehole flows, drawdowns, and transmissivity by estimating hydraulic-conductivity values in the aquifer system and gravel packs of the original and modified wells. Lithology also constrained hydraulic-conductivity estimates as regularization observations. Well encrustations caused as much as 2 µg/L increase in simulated arsenic concentration by reducing the contribution of flow from the aquifer system above the lacustrine clay deposits. Simulated arsenic concentrations in the modified well remained less than 3 µg/L over a 20-year period.  相似文献   

9.
A crude‐oil spill occurred in 1979 when a pipeline burst near Bemidji, MN. In 1998, the pipeline company installed a dual‐pump recovery system designed to remove crude oil remaining in the subsurface at the site. The remediation from 1999 to 2003 resulted in removal of about 115,000 L of crude oil, representing between 36% and 41% of the volume of oil (280,000 to 316,000 L) estimated to be present in 1998. Effects of the 1999 to 2003 remediation on the dissolved plume were evaluated using measurements of oil thicknesses in wells plus measurements of dissolved oxygen in groundwater. Although the recovery system decreased oil thicknesses in the immediate vicinity of the remediation wells, average oil thicknesses measured in wells were largely unaffected. Dissolved‐oxygen measurements indicate that a secondary plume was caused by disposal of the pumped water in an upgradient infiltration gallery; this plume expanded rapidly immediately following the start of the remediation in 1999. The result was expansion of the anoxic zone of groundwater upgradient and beneath the existing natural attenuation plume. Oil‐phase recovery at this site was shown to be challenging, and considerable volumes of mobile and entrapped oil remain in the subsurface despite remediation efforts.  相似文献   

10.
Arsenic concentrations exceeding the U.S. EPA's 10 μg/L standard are common in glacial aquifers in the midwestern United States. Previous studies have indicated that arsenic occurs naturally in these aquifers in association with metal-(hydr)oxides and is released to groundwater under reducing conditions generated by microbial oxidation of organic matter. Despite this delineation of the arsenic source and mechanism of arsenic mobilization, identification of arsenic-impacted aquifers is hindered by the heterogeneous and discontinuous nature of glacial sediments. In much of the Midwest, the hydrostratigraphy of glacial deposits is not sufficiently characterized to predict where elevated arsenic concentrations are likely to occur. This case study from southeast Wisconsin presents a detailed characterization of local stratigraphy, hydrostratigraphy, and geochemistry of the Pleistocene glacial deposits and underlying Silurian dolomite. Analyses of a single core, water chemistry data, and well construction reports enabled identification of two aquifers separated by an organic-rich aquitard. The upper, unconfined aquifer provides potable water, whereas arsenic generally exceeds 10 μg/L in the deeper aquifer. Although coring and detailed hydrostratigraphic characterization are often considered impractical, our results demonstrate that a single core improved interpretation of the complex lithology and hydrostratigraphy. This detailed characterization of hydrostratigraphy facilitated development of well construction guidelines and lays the ground work for further studies of the complex interactions among aquifer sediments, hydrogeology, water chemistry, and microbiology that lead to elevated arsenic in groundwater.  相似文献   

11.
Arsenic Removal from Natural Groundwater Using Cupric Oxide   总被引:1,自引:0,他引:1  
Groundwater is a main source of drinking water for some rural areas. People in these rural areas are potentially at risk from elevated levels of arsenic (As) due to a lack of water treatment facilities. The objectives of this study were to (1) measure As concentrations in approximately 50 groundwater samples from rural domestic wells in the western United States, (2) explore the potential of cupric oxide (CuO) particles in removal of As from groundwater samples under natural conditions (i.e., without adding competing anions and adjusting the pH or oxidation state), and (3) determine the effects of As removal on the chemistry of groundwater samples. Forty‐six groundwater well samples from rural domestic areas were tested in this study. More than 50% of these samples exceeded the U.S. Environmental Protection Agency Maximum Contaminant Limit (US EPA MCL) of 10 µg/L for As. CuO particles effectively removed As from groundwater samples across a wide range of pH (7.11 and 8.95) and concentrations of competing anions including phosphate (<0.05 to 3.06 mg/L), silica (<1 to 54.5 mg/L), and sulfate (1.3 to 735 mg/L). Removal of As showed minor effects on the chemistry of groundwater samples, therefore most of the water quality parameters remained within the US EPA MCLs. Overall, results of this study could help develop a simple one‐step process to remove As from groundwater.  相似文献   

12.
Sudicky EA  Illman WA 《Ground water》2011,49(5):630-648
This article summarizes several of many field-based studies of subsurface contaminant transport conducted over the last 30 years at the Canadian Forces Base (CFB) Borden site. The field research initially consisted of extensive monitoring of a leachate plume from an abandoned landfill and its analytical and numerical modeling. Lessons learned from these initial studies led to the execution and interpretation of a variety of tracer tests involving conservative and reactive/organic solutes tests performed at various scales. The lessons learned from these tracer tests revealed a number of deficiencies in classical theories of contaminant dispersion and reaction processes as they occur in groundwater, and thus spawned a new era of process-oriented research within the hydrogeological community. The extensively monitored tracer tests were followed by controlled spills of organic contaminants to observe their subsurface movement and distribution as well as the emplacement of a variety of contaminant sources in the saturated and unsaturated zones to study the ambient transport of contaminants. The controlled spills and emplaced sources of various contaminants were then utilized for testing various active and passive remediation technologies. These studies have led to fundamental insights and lessons learned that have significantly contributed to research on contaminant transport in both the saturated and unsaturated zones. Over the years, data generated by the University of Waterloo (UW) researchers and their collaborators continues to be examined by various research groups and has led to additional new insights on subsurface transport of various chemicals.  相似文献   

13.
Arsenic is a well‐known groundwater contaminant that causes toxicological and carcinogenic effects in humans. Predicting the transport of arsenic in the subsurface is often problematic because of its complex sorption characteristics. Numerous researchers have reported that arsenic sorption on soil material is initially fast and then subsequently slow. A dual‐site numerical sorption model was previously developed to describe arsenic desorption from arsenic‐contaminated soils in batch experiments in terms of two different release mechanisms. Experiments involving synthetic acid rain leaching of four arsenic‐contaminated soil columns were performed to verify the dual‐site numerical sorption model in the context of one‐dimensional vertical transport. The fitted models successfully simulated the signature long tailings and the two‐stage arsenic leaching patterns for all four soil columns. The dual‐site sorption model was incorporated within the general solute transport simulation code Modular Three‐Dimensional Multispecies (MT3DMS), version 5.10. The resulting version was named MT3DDS and is available for public access. This experimental study has shown that MT3DDS is capable of simulating phase redistribution during transport, and thus provides a new numerical tool for simulating arsenic transport in the subsurface.  相似文献   

14.
Chloride contamination of groundwater in urban areas due to deicing is a well‐documented phenomenon in northern climates. The objective of this study was to evaluate the effects of permeable pavement on degraded urban groundwater. Although low impact development practices have been shown to improve stormwater quality, no infiltration practice has been found to prevent road salt chlorides from entering groundwater. The few studies that have investigated chlorides in permeable asphalt have involved sampling directly beneath the asphalt; no research has looked more broadly at surrounding groundwater conditions. Monitoring wells were installed upgradient and downgradient of an 860 m2 permeable asphalt parking lot at the University of Connecticut (Storrs, Connecticut). Water level and specific conductance were measured continuously, and biweekly samples were analyzed for chloride. Samples were also analyzed for sodium (Na), calcium (Ca), and magnesium (Mg). Analysis of variance analysis indicated a significantly (p < 0.001) lower geometric mean Cl concentration downgradient (303.7 mg/L) as compared to upgradient (1280 mg/L). Concentrations of all alkali metals increased upgradient and downgradient during the winter months as compared to nonwinter months, indicating that cation exchange likely occurred. Despite the frequent high peaks of chloride in the winter months as well as the increases in alkali metals observed, monitoring revealed lower Cl concentrations downgradient than upgradient for the majority of the year. These results suggest that the use of permeable asphalt in impacted urban environments with high ambient chloride concentrations can be beneficial to shallow groundwater quality, although these results may not be generalizable to areas with low ambient chloride concentrations.  相似文献   

15.
Geogenic arsenic in drinking water is a worldwide problem. For private well owners, testing (e.g., private or government laboratory) is the main method to determine arsenic concentration. However, the temporal variability of arsenic concentrations is not well characterized and it is not clear how often private wells should be tested. To answer this question, three datasets, two new and one publicly available, with temporal arsenic data were utilized: 6370 private wells from New Jersey tested at least twice since 2002, 2174 wells from the USGS NAWQA database, and 391 private wells sampled 14 years apart from Bangladesh. Two arsenic drinking water standards are used for the analysis: 10 µg/L, the WHO guideline and EPA standard or maximum contaminant level (MCL) and 5 µg/L, the New Jersey MCL. A rate of change was determined for each well and these rates were used to predict the temporal change in arsenic for a range of initial arsenic concentrations below an MCL. For each MCL and initial concentration, the probability of exceeding an MCL over time was predicted. Results show that to limit a person to below a 5% chance of drinking water above an MCL, wells that are ½ an MCL and above should be tested every year and wells below ½ an MCL should be tested every 5 years. These results indicate that one test result below an MCL is inadequate to ensure long-term compliance. Future recommendations should account for temporal variability when creating drinking water standards and guidance for private well owners.  相似文献   

16.
Exposure from groundwater contamination to aquatic receptors residing in receiving surface water is dependent upon the rate of contaminated groundwater discharge. Characterization of groundwater fluxes is challenging, especially in coastal environments where tidal fluctuations result in transient groundwater flows towards these receptors. This can also be further complicated by the high spatial heterogeneity of subsurface deposits enhanced by anthropogenic influences such as the mixing of natural sediments and backfill materials, the presence of subsurface built structures such as sheet pile walls or even occurrence of other sources of contaminant discharge. In this study, the finite volume point dilution method (FVPDM) was successfully used to characterize highly transient groundwater flows and contaminant mass fluxes within a coastal groundwater flow system influenced by marked tides. FVPDM tests were undertaken continuously for more than 48 h at six groundwater monitoring wells, in order to evaluate groundwater flow dynamics during several tide cycles. Contaminant concentrations were measured simultaneously which allowed calculating contaminant mass fluxes. The study highlighted the importance of the aquifer heterogeneity, with groundwater fluxes ranging from 10−7 to 10−3 m/s. Groundwater flux monitoring enabled a significant refinement of the conceptual site model, including the fact that inversion of groundwater fluxes was not observed at high tide. Results indicated that contaminant mass fluxes were particularly higher at a specific monitoring well, by more than three orders of magnitude, than at other wells of the investigated aquifer. This study provided crucial information for optimizing further field investigations and risk mitigation measures.  相似文献   

17.
A systematic approach is presented for the design of a multiphase vadose zone monitoring system recognizing that, as in ground water monitoring system design, complete subsurface coverage is not practical. The approach includes identification and prioritization of vulnerable areas: select ion of cost-effective indirect monitoring methods that will provide early warning of contaminant migration: selection of direct monitoring methods for diagnostic confirmation; identification of background monitoring locations; and identification of an appropriate temporal monitoring plan. An example of a monitoring system designed for a solid waste landfill is presented and utilized to illustrate the approach and provide details of system implementation. The example design described incorporates the use of neutron moisture probes deployed in both vertical and horizontal access tubes beneath the lcachate recovery collection system of the landfill. Early warning of gaseous phase contaminant migration is monitored utilizing whole-air active soil gas sampling points deployed in gravel- filled trenches beneath the subgrade. Diagnostic confirmation of contaminant migration is provided utilizing pore- liquid samplers. Conservative tracers can be used to distinguish between chemical species released by a landfill from those attributable to other (e.g. off-site) sources or present naturally in the subsurface. A discussion of background monitoring point location is also presented.  相似文献   

18.
Arsenotrophic bacteria contribute to the nutrient cycling in arsenic (As) affected groundwater. This study employed a culture‐independent and ‐dependent investigation of arsenotrophic microbiomes in As affected groundwater samples collected from Madhabpur, Sonatengra, and Union Porishod in Singair Upazila, Manikganj, Bangladesh. Total As contents, detected by Atomic Absorption Spectrophotometry (AAS) of the samples, were 47 µg/L (Madhabpur, SNGW‐1), 53 µg/L (Sonatengra, SNGW‐2), and 12 µg/L (Union porishod, SNGW‐3), whereas the control well (SNGW‐4; depths >150 m) showed As content of 6 µg/L. Denaturing Gradient Gel Electrophoresis (DGGE) analysis of the amplified 16S rRNA gene from As‐affected groundwater samples revealed the dominance of aerobic bacteria Pseudomonas within heterogeneous bacterial populations. DGGE of heterotrophic enrichments supplemented with arsenite [As (III)] for 4 weeks showed the dominance of Chryseobacterium, Flavobacterium, and Aquabacterium, whereas the dominant genera in that of autotrophic enrichments were Aeromonas, Acinetobacter, and Pseudomonas. Cultured bacteria retrieved from both autotrophic and heterotrophic enrichments were distinguished into nine genotypes belonging to Chryseobacterium, Acinetobacter, Escherichia, Pseudomonas, Stenotrophomonas, Janibacter, Staphylococcus, and Bacillus. They exhibited varying range of As(III) tolerance from 4 to 27 mM. As(III) transformation potential was confirmed within the isolates with oxidation rate as high as 0.143 mM/h for Pseudomonas sp. Sn 28. The arsenotrophic microbiome specifies their potential role in groundwater As‐cycling and their genetic information provide the scientific basis for As‐bioremediation.  相似文献   

19.
Wilkin RT  Puls RW  Sewell GW 《Ground water》2003,41(4):493-503
Geochemical and microbiological factors that control long-term performance of subsurface permeable reactive barriers were evaluated at the Elizabeth City, North Carolina, and the Denver Federal Center, Colorado, sites. These ground water treatment systems use zero-valent iron filings (Peerless Metal Powders Inc.) to intercept and remediate chlorinated hydrocarbon compounds at the Denver Federal Center (funnel-and-gate system) and overlapping plumes of hexavalent chromium and chlorinated hydrocarbons at Elizabeth City (continuous wall system). Zero-valent iron at both sites is a long-term sink for carbon, sulfur, calcium, silicon, nitrogen, and magnesium. After about four years of operation, the average rates of inorganic carbon (IC) and sulfur (S) accumulation are 0.09 and 0.02 kg/m2/year, respectively, at Elizabeth City where upgradient waters contain <400 mg/L of total dissolved solids (TDS). At the Denver Federal Center site, upgradient ground water contains 1000 to 1200 mg/L TDS and rates of IC and S accumulation are as high as 2.16 and 0.80 kg/m2/year, respectively. At both sites, consistent patterns of spatially variable mineral precipitation and microbial activity are observed. Mineral precipitates and microbial biomass accumulate the fastest near the upgradient aquifer-Fe0 interface. Maximum net reductions in porosity due to the accumulation of sulfur and inorganic carbon precipitates range from 0.032 at Elizabeth City to 0.062 at the Denver Federal Center (gate 2) after about four years. Although pore space has been lost due the accumulation of authigenic components, neither site shows evidence of pervasive pore clogging after four years of operation.  相似文献   

20.
The U.S. Environmental Protection Agency (EPA) maximum contaminant level (MCL) of 50 μg/L for arsenic was exceeded in 86 of 2125 water supply wells sampled over a broad geographic range in pails of Drown. Outagamie and Winnebago Counties, Wisconsin. The hydrologic and geochemical properties of the area were examined and the source of arsenic was determined to be natural, Ground water collected from two geologic formations, the St. Peter Sandstone and the overlying Platteville/Galena Dolomite, was found to be the principal source of the elevated arsenic concentrations. These two Formations supply a large portion of eastern Wisconsin private wells with their drinking water.
Three wells were found within Outagamie County to have an unusually low pH. Results suggest that the cause of the low pH in these wells is of natural origin induced by the oxidation of iron sulfide minerals. In this reaction iron sulfide minerals are oxidized. forming sulfuric acid causing a low pH and a high concentration of various metals to leach from native rock formations into the water supply.
Based on the data gathered from this study, an arsenic advisory area was designated for both Outagamie and Winnebago Counties. Guidelines were developed for well drillers and owners constructing new wells within the advisory area to reduce the likelihood of arsenic presence in the water supply. Fifteen wells containing arsenic exceeding the MCL were successfully reconstructed or new wells were constructed based on the guidelines developed. These constructions substantially reduced arsenic levels in the well water supplies.  相似文献   