首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Groundwater is not a sustainable resource, unless abstraction is balanced by recharge. Identifying the sources of recharge in a groundwater basin is critical for sustainable groundwater management. We studied the importance of river water recharge to groundwater in the south‐eastern San Joaquin Valley (24,000 km2, population 4 million). We combined dissolved noble gas concentrations, stable isotopes, tritium, and carbon‐14 analyses to analyse the sources, mechanisms, and timescales of groundwater recharge. Area‐representative groundwater sampling and numerical model input data enabled a stable isotope mass balance and quantitative estimates of river and local recharge. River recharge, identified by a lighter stable isotope signature, represents 47 ± 4% of modern groundwater in the San Joaquin Valley (recharged after 1950) but only 26 ± 4% of premodern groundwater (recharged before 1950). This implies that the importance of river water recharge in the San Joaquin valley has nearly doubled and is likely the result of a 40% increase in total recharge, caused by river water irrigation return flows and increased stream depletion and river recharge due to groundwater pumping. Compared with the large and long‐duration capacity for water storage in the subsurface, storage of water in rivers is limited in time and volume, as evidenced by cold river recharge temperatures resulting from fast infiltration and recharge. Groundwater banking of seasonal surface water flows and expansion of managed aquifer recharge practices therefore appear to be a natural and promising method for increasing the resilience of the San Joaquin Valley water supply system.  相似文献   

2.
Over the past century, groundwater levels in California's San Joaquin Valley have dropped by more than 30 m in some areas mostly due to excessive groundwater extraction used to irrigate agricultural lands and sustain a growing population. Between 2012 and 2015, California experienced the worst drought in its recorded history, depleting surface water supplies and further exacerbating groundwater depletion in the region. Due to a lack of groundwater regulation, exact quantities of extracted groundwater in California are unknown and hard to quantify. Recent adoption of the Sustainable Groundwater Management Act has intensified efforts to identify sustainable groundwater use. However, understanding sustainable use in a highly productive agricultural system with an extremely complex surface water allocation system, variable groundwater use, and spatially extensive and diverse irrigation practices is no easy task. Using an integrated hydrologic model coupled with a land surface model, we evaluated how water management activities, specifically a suite of irrigation and groundwater pumping scenarios, impact surface water–groundwater fluxes and storage components and how those activities and the relationships between them change during drought. Results showed that groundwater pumping volume had the most significant impact on long-term water storage changes. A comparison with total water storage anomaly (TWSA) estimates from NASA's Gravity Recover and Climate Experiment (GRACE) provided some insight regarding which combinations of pumping and irrigation matched the GRACE TWSA estimates, lending credibility to these scenarios. In addition, the majority of long-term water storage changes during the recent drought occurred in groundwater storage in the deeper subsurface.  相似文献   

3.
Water from the San Joaquin Delta, having chloride concentrations up to 3590 mg/L, has intruded fresh water aquifers underlying Stockton, California. Changes in chloride concentrations at depth within these aquifers were evaluated using sequential electromagnetic (EM) induction logs collected during 2004 through 2007 at seven multiple‐well sites as deep as 268 m. Sequential EM logging is useful for identifying changes in groundwater quality through polyvinyl chloride‐cased wells in intervals not screened by wells. These unscreened intervals represent more than 90% of the aquifer at the sites studied. Sequential EM logging suggested degrading groundwater quality in numerous thin intervals, typically between 1 and 7 m in thickness, especially in the northern part of the study area. Some of these intervals were unscreened by wells, and would not have been identified by traditional groundwater sample collection. Sequential logging also identified intervals with improving water quality—possibly due to groundwater management practices that have limited pumping and promoted artificial recharge. EM resistivity was correlated with chloride concentrations in sampled wells and in water from core material. Natural gamma log data were used to account for the effect of aquifer lithology on EM resistivity. Results of this study show that a sequential EM logging is useful for identifying and monitoring the movement of high‐chloride water, having lower salinities and chloride concentrations than sea water, in aquifer intervals not screened by wells, and that increases in chloride in water from wells in the area are consistent with high‐chloride water originating from the San Joaquin Delta rather than from the underlying saline aquifer.  相似文献   

4.
Specific electrical conductivity (SEC), total dissolved solids (TDS), and silica (SiO2) are ground-water quality parameters routinely measured in a laboratory. Electrical conductivity measurements are made quickly and are less costly than TDS measurements. Once the relationship between the parameters is determined by regression analysis, TDS can be estimated quickly from the SEC and SiO2 measurements. Water quality data from 25 city wells in Fresno, California, and historical ground-water quality data from the adjacent San Joaquin River/Kings River alluvial interfan (central San Joaquin Valley, California), the Kaweah River alluvial fan, and the Kern River alluvial fan (southern San Joaquin Valley) were used in this investigation. For the specific hydrologic areas studied, the model's TDS predictive ability is improved when SiO2 is included with SEC as the independent variables.  相似文献   

5.
Pesticide residues in ground water of the San Joaquin Valley, California   总被引:1,自引:0,他引:1  
A regional assessment of non-point-source contamination of pesticide residues in ground water was made of the San Joaquin Valley, an intensively farmed and irrigated structural trough in central California. About 10% of the total pesticide use in the USA is in the San Joaquin Valley. Pesticides detected include atrazine, bromacil, 2.4-DP, diazinon, dibromochloropropane, 1,2-dibromoethane, dicamba, 1,2-dichloropropane, diuron, prometon, prometryn, propazine and simazine. All are soil applied except diazinon.

Pesticide leaching is dependent on use patterns, soil texture, total organic carbon in soil, pesticide half-life and depth to water table. Leaching is enhanced by flood-irrigation methods except where the pesticide is foliar applied such as diazinon. Soils in the western San Joaquin Valley are fine grained and are derived primarily from marine shales of the Coast Ranges. Although shallow ground water is present, the fewest number of pesticides were detected in this region. The fine-grained soil inhibits pesticide leaching because of either low vertical permeability or high surface area; both enhance adsorption on to solid phases. Soils of the valley floor tend to be fine grained and have low vertical permeability. Soils in the eastern part of the valley are coarse grained with low total organic carbon and are derived from Sierra Nevada granites. Most pesticide leaching is in these alluvial soils, particularly in areas where depth to ground water is less than 30m. The areas currently most susceptible to pesticide leaching are eastern Fresno and Tulare Counties.

Tritium in water molecules is an indicator of aquifer recharge with water of recent origin. Pesticide residues transported as dissolved species were not detected in non-tritiated water. Although pesticides were not detected in all samples containing high tritium, these samples are indicative of the presence of recharge water that interacted with agricultural soils.  相似文献   


6.
A transient flow modeling analysis for potential public-supply wells on western Cape Cod, Massachusetts, demonstrates the difference between transient and steady-state recharge areas can have important implications for wellhead protection. An example of a single pumping well illustrates that commonly used steady-state time-related capture areas do not represent the recharge area and travel times of water being pumped from the well until sufficient time has elapsed for steady-state flow conditions to be established. Until that time, transient recharge areas are needed to account for the portion of water discharging from the well that entered the aquifer before pumping started. An example of two pumping wells demonstrates the same area at the water table cannot supply water to more than one well under steady-state flow conditions. Transient recharge areas to multiple wells can overlap, however, until steady-state flow conditions are established. The same area can, therefore, be a source of water to more than one well during early pumping times, and the water pumped from a given well may derive from source areas, including contaminated areas, that do not lie within the well's steady-state recharge area.  相似文献   

7.
Artificial recharge through a thick, heterogeneous unsaturated zone   总被引:2,自引:0,他引:2  
Thick, heterogeneous unsaturated zones away from large streams in desert areas have not previously been considered suitable for artificial recharge from ponds. To test the potential for recharge in these settings, 1.3 x 10(6) m(3) of water was infiltrated through a 0.36-ha pond along Oro Grande Wash near Victorville, California, between October 2002 and January 2006. The pond overlies a regional pumping depression 117 m below land surface and is located where thickness and permeability of unsaturated deposits allowed infiltration and saturated alluvial deposits were sufficiently permeable to allow recovery of water. Because large changes in water levels caused by nearby pumping would obscure arrival of water at the water table, downward movement of water was measured using sensors in the unsaturated zone. The downward rate of water movement was initially as high as 6 m/d and decreased with depth to 0.07 m/d; the initial time to reach the water table was 3 years. After the unsaturated zone was wetted, water reached the water table in 1 year. Soluble salts and nitrate moved readily with the infiltrated water, whereas arsenic and chromium were less mobile. Numerical simulations done using the computer program TOUGH2 duplicated the downward rate of water movement, accumulation of water on perched zones, and its arrival at the water table. Assuming 10 x 10(6) m(3) of recharge annually for 20 years, a regional ground water flow model predicted water level rises of 30 m beneath the ponds, and rises exceeding 3 m in most wells serving the nearby urban area.  相似文献   

8.
Local surface water and stormflow were infiltrated intermittently from a 40-ha basin between September 2003 and September 2007 to determine the feasibility of recharging alluvial aquifers pumped for public supply, near Stockton, California. Infiltration of water produced a pressure response that propagated through unconsolidated alluvial-fan deposits to 125 m below land surface (bls) in 5 d and through deeper, more consolidated alluvial deposits to 194 m bls in 25 d, resulting in increased water levels in nearby monitoring wells. The top of the saturated zone near the basin fluctuates seasonally from depths of about 15 to 20 m. Since the start of recharge, water infiltrated from the basin has reached depths as great as 165 m bls. On the basis of sulfur hexafluoride tracer test data, basin water moved downward through the saturated alluvial deposits until reaching more permeable zones about 110 m bls. Once reaching these permeable zones, water moved rapidly to nearby pumping wells at rates as high as 13 m/d. Flow to wells through highly permeable material was confirmed on the basis of flowmeter logging, and simulated numerically using a two-dimensional radial groundwater flow model. Arsenic concentrations increased slightly as a result of recharge from 2 to 6 μg/L immediately below the basin. Although few water-quality issues were identified during sample collection, high groundwater velocities and short travel times to nearby wells may have implications for groundwater management at this and at other sites in heterogeneous alluvial aquifers.  相似文献   

9.
MTBE and gasoline hydrocarbons in ground water of the United States   总被引:1,自引:0,他引:1  
The occurrence of methyl tert-butyl ether (MTBE) and gasoline hydrocarbons was examined in three types of studies of ground water conducted by the U.S. Geological Survey: major aquifer surveys, urban land-use studies, and agricultural land-use studies. The detection frequency of MTBE was dependent on the study type, with the highest detection frequency in urban land-use studies. Only 13 ground water samples from all study types, or 0.3%, had concentrations of MTBE that exceeded the lower limit of the U.S. EPA's Drinking-Water Advisory. The detection frequency of MTBE was highest in monitoring wells located in urban areas and in public supply wells. The detection frequency of any gasoline hydrocarbon also was dependent on study type and generally was less than the detection frequency of MTBE. The probability of detecting MTBE in ground water was strongly associated with population density, use of MTBE in gasoline, and recharge. Ground water in areas with high population density, in areas where MTBE is used as a gasoline oxygenate, and in areas with high recharge rates had a greater probability of MTBE occurrence. Also, ground water from public supply wells and shallow ground water underlying urban land-use areas had a greater probability of MTBE occurrence compared to ground water from domestic wells and ground water underlying rural land-use areas. The probability of detecting MTBE in ground water was weakly associated with the density of leaking underground storage tanks, soil permeability, and aquifer consolidation, and only concentrations of MTBE >0.5 microg/L were associated with dissolved oxygen.  相似文献   

10.
A synthesis of groundwater ages, recharge rates and information on processes affecting groundwater quality in northern China highlights the major challenges faced for sustainable management of the region's groundwater. Direct recharge rates range from hundreds of millimetres per year in the North China Plain, to tens of millimetres per year in the Loess Plateau to less than 4 mm/year in the arid northwest. Recharge rates and mechanisms to deep semiconfined and confined aquifers are poorly constrained; however, on the basis of available data, these are likely to be mostly negligible. Severe groundwater level declines (0.5–3 m/year) have occurred throughout northern China in the last three to four decades, particularly in deep aquifers. Radiocarbon dating, stable isotope and noble gas data show that the most intensively extracted deep groundwater is palaeowater, recharged under different climate and land cover conditions to the present. Reservoir construction has reduced surface runoff in mountain‐front areas that would naturally recharge regional Quaternary aquifers in many basins. In combination with intensive irrigation practices, this has resulted in the main recharge source shifting from surface runoff and mountain‐front recharge to irrigation returns. This has reduced infiltration of fresh recharge at basin margins and rapidly increased nitrate concentrations and overall mineralisation in phreatic groundwater over wide areas (in some cases to >400 mg/l and >10 g/l, respectively). In some basins, there is evidence that poor quality shallow water has leaked into deep layers (>200 m) via preferential flow, mixing with palaeowaters stored in semiconfined aquifers. High concentrations of naturally occurring fluoride and arsenic (locally >8.5 and >4 mg/l, respectively) have recently lead to the abandonment of numerous supply wells in northern China, creating further pressure on stressed water resources. Increasing water demand from direct and indirect consumption poses major challenges for water management in northern China, which must consider the full water cycle. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

11.
Abstract

Water supply to the world’s megacities is a problem of quantity and quality that will be a priority in the coming decades. Heavy pumping of groundwater beneath these urban centres, particularly in regions with low natural topographic gradients, such as deltas and floodplains, can fundamentally alter the hydrological system. These changes affect recharge area locations, which may shift closer to the city centre than before development, thereby increasing the potential for contamination. Hydrogeological simulation analysis allows evaluation of the impact on past, present and future pumping for the region of Kolkata, India, on recharge area locations in an aquifer that supplies water to over 13 million people. Relocated recharge areas are compared with known surface contamination sources, with a focus on sustainable management of this urban groundwater resource. The study highlights the impacts of pumping on water sources for long-term development of stressed city aquifers and for future water supply in deltaic and floodplain regions of the world.

Editor D. Koutsoyiannis

Citation Sahu, P., Michael, H.A., Voss, C.I., and Sikdar, P.K., 2013. Impacts on groundwater recharge areas of megacity pumping: analysis of potential contamination of Kolkata, India, water supply. Hydrological Sciences Journal, 58 (6), 1340–1360.  相似文献   

12.
Large agricultural fields in South Korea are located mostly on alluvial plains, where a significant amount of groundwater is used for heating of water‐curtain insulated greenhouses. Such greenhouses are commonly used for crop cultivation during the winter dry season from November to March. After use the groundwater is discharged directly into streams, causing groundwater depletion. A hydrogeological study was carried out in a typical agricultural area of this type, located on an alluvial aquifer near the Nakdong River. Groundwater levels, chemical characteristics, and temperatures from 68 observation wells were analyzed to determine the impacts of seasonal groundwater pumping on the groundwater system and stream‐aquifer interactions. Our results show that the groundwater system has not yet reached a state of dynamic equilibrium. Decades of excessive seasonal pumping have caused a gradual decline of groundwater levels, leading to groundwater depletion, especially in areas further from the river. Seasonal pumping has also significantly affected groundwater quality in the aquifer near the river. Groundwater temperature is decreasing (in this case a disadvantage), and saline groundwater is being diluted by induced recharge. The results of this study provide a basic outline for effective integrated water management that is widely applicable in South Korea.  相似文献   

13.
Groundwater recharge and discharge in the Akesu alluvial plain were estimated using a water balance method. The Akesu alluvial plain (4842 km2) is an oasis located in the hyperarid Tarim River basin of central Asia. The land along the Akesu River has a long history of agricultural development and the irrigation area is highly dependent on water withdrawals from the river. We present a water balance methodology to describe (a) surface water and groundwater interaction and (b) groundwater interaction between irrigated and non‐irrigated areas. Groundwater is recharged from the irrigation system and discharged in the non‐irrigated area. Uncultivated vegetation and wetlands are supplied from groundwater in the hyperarid environment. Results show that about 90% of groundwater recharge came from canal loss and field infiltration. The groundwater flow from irrigated to non‐irrigated areas was about 70% of non‐irrigated area recharge and acted as subsurface drainage for the irrigation area. This desalinated the irrigation area and supplied water to the non‐irrigated area. Salt moved to the non‐irrigation area following subsurface drainage. We conclude that the flooding of the Akesu River is a supplemental groundwater replenishment mechanism: the river desalinates the alluvial plain by recharging fresh water in summer and draining saline regeneration water in winter. Copyright © 2007 John Wiley & Sons, Ltd.  相似文献   

14.
In the late 1980s, dramatic increases in water use caused over‐exploitation of groundwater resources and deterioration of water quality in Seoul metropolitan city. To monitor changes in quantity of groundwater resources and their quality, the metropolitan government established a local groundwater monitoring network in 1997 consisting of 119 monitoring wells. Groundwater resources in the urban area were affected by various human activities, including underground construction such as subways, pumping for public or private water use, leaky sewer systems and pavements. The variation patterns of the groundwater levels were mainly classified into four types, reflecting natural recharge due to rainfall events during the wet season, artificial recharge from leaky sewer or water supply systems, and heavy groundwater pumping for drainage or flood control purposes at underground construction sites. Significantly decreasing trends of groundwater levels in the suburbs of Seoul indicate groundwater use for various agricultural activities. Subway construction lowered the water level by an average of 25 m. Electrical conductivity values showed a wide range, from 100 to 1800 µS/cm (mean 470 µS/cm). Groundwater temperature generally showed a stable pattern, except for some sensitive increases at relatively shallow monitoring wells. Detailed analysis of the monitored groundwater data would provide some helpful implications for optimal and efficient management of groundwater resources in this metropolitan city. Copyright © 2005 John Wiley & Sons, Ltd.  相似文献   

15.
India's surface water and groundwater distribution is temporally variable due to the monsoon.Agriculture is one of the dominant economic sectors in India.Groundwater quality is regularly assessed to determine usability for drinking and irrigation.In this study,World Health Organization and Bureau of Indian Standards guidelines were used to determine suitability of groundwater near artificial recharge structures(ARS) with a focus on the structures impact on groundwater quality.Groundwater resources were evaluated for irrigation suitability using electrical conductivity(EC),sodium adsorption ratio,the US Salinity Laboratory diagram,sodium concentration,Wilcox's diagram,Kelly's index,and Doneen's permeability index.EC and major ions were tested in recharge areas at different distances from the ARS.The construction of ARS at optimal distances along major streams has improved groundwater quantity and quality in the subbasin.Before construction of ARS,fluoride concentrations were higher;after construction,fluoride was reduced in most locations.Water stored in the check dam and groundwater in the wells closer to the structure were suitable for both drinking and irrigation purposes.Impact of ARS on nearby groundwater quality was observed at Pallipatti,Mulayanur,Venkadasamuthram,Pudupatti,Poyyappatti,Harurl,and Sekkampatti.More distant sites included Pappiredipatti,Nambiyappati,Menasi,Harur,Todampatti,and Adikarapatti.Data demonstrated improved groundwater quality in the area of the ARS.Through recharge,the non-potable fluoride in the region is reduced to the permissible limit for human consumption.  相似文献   

16.
Introduction of the large gravity irrigation system in the Indus Basin in the late 19th century without a drainage system resulted in a rising water table, which resulted in water logging and salinity problems over large areas. In order to cope with the salinity and water logging problem, the Pakistan government initiated installation of 10,000 tube wells in different areas. This not only resulted in the lowering of water table, but also supplemented irrigation. Resulting benefits from the irrigation opportunities motivated framers to install private tube wells. The Punjab area meets 40% of its irrigation needs from groundwater abstraction. Today, farmers apply both surface water flows and groundwater from tube wells, creating a pattern of private and public water control. Sustainable use of groundwater needs proper quantification of the resource and information on processes involved in its recharge and discharge. The field work in the Lagar irrigated area, discussed in this paper, show that within the general picture of conjunctive use of canal water and groundwater, there is a clear spatial pattern between upstream and downstream areas, with upstream areas depending much less on groundwater than downstream areas. The irrigation context in the study area proves to be highly complex, with water users having differential access to canal and tube well water, resulting in different responses of farmers with their irrigation strategies, which in turn affect the salinity and water balances on the fields.  相似文献   

17.
In South Korea, a significant amount of groundwater is used for the heating of water-curtain insulated greenhouses during the winter dry season, which had led to problems of groundwater depletion. A managed aquifer recharge (MAR) project is currently underway with the goal of preventing such groundwater depletion in a typical cultivation area, located on an alluvial aquifer near the Nam River. In the present study, FEFLOW, a three-dimensional finite element model, was used to evaluate different strategies for MAR of the cultivation areas. A conceptual model was developed to simulate the stream-aquifer dynamics under the influence of seasonal groundwater pumping and MAR. The optimal rates and duration of MAR were assessed by analyzing the recovery of the groundwater levels and the change in the groundwater temperature. The simulation results indicate that a MAR rate of 8000 m3/d effectively restores the groundwater level when the injection wells are located inside the groundwater depletion area. It is also demonstrated that starting the MAR before the beginning of the seasonal pumping is more effective. Riverbank filtration is preferable for securing the injection water owing to plentiful source of induced recharge from the river. Locating the pumping wells adjacent to the river where there are thick permeable layers could be a good strategy for minimizing decreases in the groundwater level and temperature.  相似文献   

18.
The sustainability of groundwater resources for agricultural and domestic use is dependent on both the groundwater recharge rate and the groundwater quality. The main purpose of this study was to improve the understanding of the timing, or seasonality, of groundwater recharge through the use of stable isotopes. Based on 768 groundwater samples collected from aquifers underlying natural resources districts in Nebraska, the isotopic composition of groundwater (δ2H and δ18O) was compared with that of precipitation by (a) mapping the isotopic composition of groundwater samples and (b) mapping a seasonality index for groundwater. Results suggest that for the majority of the state, groundwater recharge has a nongrowing season signature (October–April). However, the isotopic composition of groundwater suggests that in some intensively irrigated areas, human intervention in the water cycle has shifted the recharge signature towards the growing season. In other areas, a different human intervention (diversion of Platte River water for irrigation) has likely produced an apparent but possibly misleading nongrowing season recharge signal because the Platte River water differs isotopically from local precipitation. These results highlight the need for local information even when interpreting isotopic data over larger regions. Understanding the seasonality of recharge can provide insight into the optimal times to apply fertilizer, specifically in highly conductive soils with high leaching potential. In areas with high groundwater nitrate concentrations, this information is valuable for protecting the groundwater from further degradation. Although previous studies have framed nongrowing season recharge within the context of future climate change, this study also illustrates the importance of understanding how historical human intervention in the water cycle has affected groundwater recharge seasonality and subsequent implications for groundwater recharge and quality.  相似文献   

19.
A detailed investigation was carried out to evaluate long-term groundwater level fluctuation in regular monitoring wells constructed by the Ministry of Water Resources in Barka, Sultanate of Oman. For this study, groundwater level data for 71 wells and rainfall data from six stations were collected from 1984 to 2003 and analysed. Based on long-term water level fluctuation, groundwater wells are classified into three groups. In group 1, water level shows a long-term cyclic trend without yearly fluctuation whereas in group 2 the water level declined continuously until 1995 followed by a constant water level. In group 3, water level decreases continuously throughout the study periods with rapid annual cyclic variation. Group 1 wells show high water-level fluctuations (5 to 10 m) and seem to be regulated by discharge (lateral flow) from this aquifer and recharge from the adjacent Jabal Akhdar mountainous region. Constant trend in water level after 1995 in group 2 wells illustrates the advancement of saline–fresh water interface to the inland due to heavy pumping which is justified by higher electrical conductivity and Cl/HCO3 ratio. In group 3 wells, the water level dropped continuously due to overabstraction by agricultural farms and human settlements. In addition, wells existing near the recharge dams express the influences of recharge dams and rainfall, and exhibit high water-level fluctuations during heavy rainfall periods. The long-term regional variation indicates that water level drops continuously in the coastal and central parts of the study region. Linear regression analysis revealed that the decline in water level is 0·3–0·4 m year−1 near the coastal and central parts of the study area and is almost constant in the remaining area. We conclude that the contribution of man-made activities on groundwater level is well compared with natural factors. Copyright © 2007 John Wiley & Sons, Ltd.  相似文献   

20.
The purpose of this study is to obtain a better understanding of groundwater contamination processes in an arid environment (precipitation of 50 mm/year) due to cultivation. Additional aims were to study the fate of N, K, and other ions along the whole hydrological system including the soil and vadose zone, and to compare groundwater in its natural state with contaminated groundwater (through the drilling of several wells).

A combination of physical, chemical, and isotopic analyses was used to describe the hydrogeological system and the recharge trends of water and salts to the aquifers. The results indicate that intensive irrigation and fertilization substantially affected the quantity and quality of groundwater recharge. Low irrigation efficiency of about 50% contributes approximately 3.5–4 million m3/year to the hydrological system, which corresponds to 0.65 m per year of recharge in the irrigated area, by far the most significant recharge mechanism.

Two main contamination processes were identified, both linked to human activity: (1) salinization due to circulation of dissolved salts in the irrigation water itself, mainly chloride, sulfate, sodium and calcium, and (2) direct input of nitrate and potassium mainly from fertilizers.

The nitrate concentrations in a local shallow groundwater lens range between 100 and 300 mg/l and in the upper sub-aquifer are over 50 mg/l. A major source of nitrate is fertilizer N in the excess irrigation water. The isotopic compositions of δ15N–NO3 (range of 4.9–14.8‰) imply also possible contributions from nearby sewage ponds and/or manure. Other evidence of contamination of the local groundwater lens includes high concentrations of K (20–120 mg/l) and total organic carbon (about 10 mg/l).  相似文献   


设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号