首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
The aim of this paper was to propose a design guideline for using visco‐elastic dampers for the control of building structures subjected to earthquake loading as well as suspension roof structures subjected to wind loading. The active control algorithm was used to calculate the control forces. Based on the single‐mode approach the control forces were transformed to the forces which visco‐elastic dampers can provide. Application of the method to the design of the building structure with passive damping devices in the bracing system and to the suspension roof with dampers was studied. Through the application of optimal control theory a systematic design procedure to implement dampers in structures is proposed. Copyright © 2000 John Wiley & Sons, Ltd.  相似文献   

2.
A new type of damper with friction-variable characteristics   总被引:1,自引:0,他引:1  
Professor T.T.Soong is one of the early pioneers in fi eld of earthquake response control of structures.A new type of smart damper,which is based on an Energy Dissipating Restraint(EDR),is presented in this paper.The EDR by Nims and Kelly,which has a triangle hysteretic loop,behaves like an active variable stiffness system(AVS) and possesses the basic characteristics of a linear viscous damper but has diffi culty in capturing the output and large stroke simultaneously needed for practical applicataions in e...  相似文献   

3.
彭勇波  李杰 《地震学刊》2011,(5):483-489
本研究发展了结构地震反应性态的随机最优控制理论和方法。这一研究建立在物理随机系统思想的新理论框架下,突破了以I^to随机微分方程描述动力系统的经典随机最优控制的藩篱。提出了基于系统二阶统计量评价、单目标超越概率和多目标能量均衡的控制器参数设计准则,以及基于概率可控指标的控制器位置设计准则,并将它们统一为物理随机最优控制的广义最优控制律。数值算例分析表明,本文发展的物理随机最优控制方法能够实现结构地震反应性态的精细化控制。  相似文献   

4.
The majority of the recent research effort on structural control considers two‐dimensional plane structures. However, not all buildings can be modelled as plane structures, thus limiting the capability of the proposed procedures only to regular and symmetrical structures. A new procedure is developed in this paper to analyse three‐dimensional buildings utilizing passive and active control devices. In the building model, the floors are assumed rigid in their own plane resulting in three degrees of freedom at each floor. Two types of active control devices utilizing an active tuned mass damper and an active bracing system are considered. The effect of passive mass dampers and active control force in the equations of motion is incorporated by using the Hamilton's principle. The passive parameters of the dampers as well as the controller gain is then optimized using a genetic based optimizer where the H2, H and L1 norms are taken as the objective functions. Copyright © 2000 John Wiley & Sons, Ltd.  相似文献   

5.
A method for design of an active control system for multistorey structures using Electrorheological (ER) dampers is presented. Incorporated at various levels of a structural frame, ER dampers are used to improve the response of the structure during earthquakes. Optimal control theory was used to design the ER devices. The aim of the design is to find the most suitable combination of the minimum required forces produced by the ER dampers to obtain the optimal structural response. The mechanical response of ER fluid dampers is regulated by an electric field, depending on the displacements and velocities of the frame. Numerical analysis of an ER damped seven-storey structure is represented as an example. Significant improvement of the structural response was obtained using optimal active controlled ER dampers compared to passive controlled and uncontrolled structures. Copyright © 1999 John Wiley & Sons, Ltd.  相似文献   

6.
This paper presents a theoretical study of a predictive active control system used to improve the response of multi‐degree‐of‐freedom (MDOF) structures to earthquakes. As an example a building frame equipped with electrorheological (ER) dampers is considered. The aim of the design is to find a combination of forces that are produced by the ER dampers in order to obtain an optimal structural response. The mechanical response of ER fluid dampers is regulated by an electric field. Linear auto‐regressive model with exogenous input (ARX) is used to predict the displacements and the velocities of the frame in order to overcome the time‐delay problem in the control system. The control forces in the ER devices are calculated at every time step by the optimal control theory (OCT) according to the values of the displacements and of the velocities that are predicted at the next time step at each storey of the structure. A numerical analysis of a seven‐storey ER damped structure is presented as an example. It shows a significant improvement of the structural response when the predictive active control system is applied compared to that of an uncontrolled structure or that of a structure with controlled damping forces with time delay. The structure's displacements and velocities that were used to obtain the optimal control forces were predicted according to an ‘occurring’ earthquake by the ARX model (predictive control). The response was similar to that of the structure with control forces that were calculated from a ‘known’ complete history of the earthquake's displacement and velocity values, and were applied without delay (instantaneous control). Copyright © 2000 John Wiley & Sons, Ltd.  相似文献   

7.
A computational method of energy evaluation is derived to study the elastic responses and energy distribution of actively controlled single‐degree‐of‐freedom (SDOF) structures during earthquakes. Contrary to the common perception that applying active control force pumps energy into the structure, the applied control force can actually reduce the energy in the structure by reducing the input energy from earthquakes to the structure. In addition, applying control force can dissipate a large amount of energy in the structure when this control force is applied in the direction opposite to the displacement and velocity responses. To demonstrate this energy mechanism in active controlled structures, the two most popular control algorithms, optimal linear control (OLC) and instantaneous optimal control (IOC) algorithms, are used to calculate the control response and energy spectra. One‐step time delay is incorporated into the algorithms to take into consideration the practical aspect of active control. The effects of different earthquakes and damping ratios on control energy and response spectra are studied. These studies show that both OLC and IOC are very effective in reducing the structural displacement and velocity responses by reducing the input earthquake energy as well as dissipating a large amount of energy in the structure. Copyright © 2001 John Wiley & Sons, Ltd.  相似文献   

8.
This paper deals with the optimal design of yielding metallic dampers and friction dampers together as they both have similar design characteristics and parameters. Ample tests and analytical studies have confirmed the effectiveness of these energy dissipation devices for seismic response control and protection of building structures. Since these devices are strongly non‐linear with several parameters controlling their behaviour, their current design procedures are usually cumbersome and not optimal. In this paper, a methodology is presented to determine the optimal design parameters for the devices installed at different locations in a building for a desired performance objective. For a yielding metallic damper, the design parameters of interest are the device yield level, device stiffness, and brace stiffness. For a friction device, the parameters are the slip load level and brace stiffness. Since the devices and the structures installed with these devices behave in a highly non‐linearly manner, and thus must be evaluated by a step‐by‐step time history approach, the genetic algorithm is used to obtain the globally optimal solution. This optimal search approach allows an unusual flexibility in the choice of performance objectives. For demonstration purposes, several sets of numerical examples of optimal damper designs with different performance objectives are presented. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

9.
To limit the response of structures during external disturbances such as strong winds or large seismic events, structural control systems can be used. In the structural engineering field, attention has been shifted from active control to semi‐active control systems. Unlike active control system devices, semi‐active devices are compact, have efficient power consumption characteristics and are less expensive. As a result, an environment of a large number of actuators and sensors will result, rendering a complex large‐scale dynamic system. Such a system is best controlled by a decentralized approach such as market‐based control (MBC). In MBC, the system is modelled as a market place of buyers and sellers that leads to an efficient allocation of control power. The resulting MBC solution is shown to be locally Pareto optimal. This novel control approach is applied to three linear structural systems ranging from a one‐storey structure to a 20‐storey structure, all controlled by semi‐active hydraulic dampers. It is shown that MBC is competitive in the reduction of structural responses during large seismic loadings as compared to the centralized control approach of the linear quadratic regulation controller. Copyright © 2002 John Wiley & Sons, Ltd.  相似文献   

10.
This study uses a semi‐active viscous damper with three different control laws to reshape the structural hysteresis loop and mitigate structural response, referred to as 1–4, 1–3 and 2–4 devices, respectively. The 1–4 control law provides damping in all four quadrants of the force‐displacement graph (it behaves like a standard viscous damper), the 1–3 control law provides resisting forces only in the first and third quadrants, and the 2–4 control law provides damping in the second and fourth quadrants. This paper first outlines the linear single degree of freedom structural performance when the three types of semi‐active viscous dampers are applied. The results show that simultaneous reduction in both displacement and base‐shear demand is only available with the semi‐active 2–4 device. To enable guidelines for adding a 2–4 device into the design procedure, damping reduction factors (RFξs) are developed, as they play an important role and provide a means of linking devices to design procedures. Three methods are presented to obtain RFξ and equivalent viscous damping of a structure with a 2–4 semi‐active viscous damper. In the first method, the relationship between RFξ and the damping of a semi‐active structure can be obtained by calculating the area under the force‐deformation diagram. The second and third method modified the Eurocode8 formula of RFξ and smoothed results from analysis, respectively. Finally, a simple method is proposed to incorporate the design or retrofit of structures with simple, robust and reliable 2–4 semi‐active viscous dampers using standard design approaches. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

11.
The optimum design of seismic structures equipped with active controls is presented. The design variables are structural parameters, such as structural stiffness or moment of inertia. The optimization procedure is carried out in two stages. First, the optimal control forces are expressed in closed form, as implicit functions of the design variables. In the second stage, the structural parameters are varied in order to minimize a structural weight objective function. The algorithm is applied to structural systems under earthquake excitations, for displacement, frequency and control force constraints.  相似文献   

12.
大跨径钢管混凝土拱桥减震控制装置参数的研究   总被引:1,自引:0,他引:1  
大跨度桥梁结构的减震控制研究对于桥梁结构的抗震安全具有重要意义。本文以主跨368m的茅草街大桥为研究对象,基于ANSYS建立了该桥的三维有限元模型,并采用子空间迭代法分析了该桥的动力特性。在此基础上进行了大跨度钢管混凝土拱桥的地震响应及减震控制研究,重点进行了弹性连接装置和粘滞阻尼器减震效果的参数敏感性分析,并对比分析了不同位置布设减震装置时的效果。结果表明,纵飘振型对该桥肋纵向相对位移的贡献最大;弹性连接装置和阻尼器均能有效减小地震作用下该桥的肋梁纵向相对位移;综合考虑各关键部位的地震响应时,同时采用两类减震装置并将其分散布置时的减震效果最佳。结论可供大跨度中承式钢管混凝土系杆拱桥的抗震设计参考。  相似文献   

13.
本文建立了基于二次型性能指标的结构控制系统控制器最优布置方法。以控制器撤除时的系统最优控制性能指标增量作为控制器对系统最优控制的贡献,并用做确定经济的控制器数量和最优控制器位置的定量分析准则。本文中的控制器位置和控制器设计采用同一个优化性能指标,使得控制系统设计为最优。根据逼近满设置控制器结构控制系统的最优状态求得控制器降阶后等价的反馈控制增益。应用本文的方法对剪切模型框架结构上安装的锚索控制器进行了控制器的总体优化设计。数值分析表明,本文提出的控制器数量、位置和参数优化方法不仅易于实现,而且甚为有效。  相似文献   

14.
Semi‐active control of buildings and structures for earthquake hazard mitigation represents a relatively new research area. Two optimal displacement control strategies for semi‐active control of seismic response of frame structures using magnetorheological (MR) dampers or electrorheological (ER) dampers are proposed in this study. The efficacy of these displacement control strategies is compared with the optimal force control strategy. The stiffness of brace system supporting the smart damper is also taken into consideration. An extensive parameter study is carried out to find the optimal parameters of MR or ER fluids, by which the maximum reduction of seismic response may be achieved, and to assess the effects of earthquake intensity and brace stiffness on damper performance. The work on example buildings showed that the installation of the smart dampers with proper parameters and proper control strategy could significantly reduce seismic responses of structures, and the performance of the smart damper is better than that of the common brace or the passive devices. The optimal parameters of the damper and the proper control strategy could be identified through a parameter study. Copyright © 2000 John Wiley & Sons, Ltd.  相似文献   

15.
A computational algorithm for maximizing the control efficiency in actively controlling the elastic structural responses during earthquake is proposed. Study of optimal linear control using a single degree of freedom shows that applying active control is very effective in reducing the structural displacement and velocity responses for long‐period structures, but at the same time it has an adverse effect in increasing the absolute acceleration response. The extent of this adverse effect reduces the effectiveness of the control system, and therefore it poses a limit on the maximum control force in order to provide maximum control efficiency. In view of this shortcoming, maximum control energy dissipation is used to define the most effective optimal linear control law. Less displacement and velocity response are expected as larger control force is applied, but there is always a limit that maximum control energy can be dissipated. This study shows that this limit depends on the structural characteristics as well as the input ground motion, and a general trend is that the maximum control energy decreases as damping increases. Finally, application of the proposed algorithm on a six‐storey hospital building is presented to show the effectiveness of using optimal linear control on a multi‐degree‐of‐freedom system from the control energy perspectives. Copyright © 2001 John Wiley & Sons, Ltd.  相似文献   

16.
Structural vibration control using active or passive control strategy is a viable technology for enhancing structural functionality and safety against natural hazards such as strong earthquakes and high wind gusts. Both the active and passive control systems have their limitations. The passive control system has limited capability to control the structural response whereas the active control system depends on external power. The power requirement for active control of civil engineering structures is usually quite high. Thus, a hybrid control system is a viable solution to alleviate some of the limitations. In this paper a multi‐objective optimal design of a hybrid control system for seismically excited building structures has been proposed. A tuned mass damper (TMD) and an active mass driver (AMD) have been used as the passive and active control components of the hybrid control system, respectively. A fuzzy logic controller (FLC) has been used to drive the AMD as the FLC has inherent robustness and ability to handle the non‐linearities and uncertainties. The genetic algorithm has been used for the optimization of the control system. Peak acceleration and displacement responses non‐dimensionalized with respect to the uncontrolled peak acceleration and displacement responses, respectively, have been used as the two objectives of the multi‐objective optimization problem. The proposed design approach for an optimum hybrid mass damper (HMD) system, driven by FLC has been demonstrated with the help of a numerical example. It is shown that the optimum values of the design parameters of the hybrid control system can be determined without specifying the modes to be controlled. The proposed FLC driven HMD has been found to be very effective for vibration control of seismically excited buildings in comparison with the available results for the same example structure but with a different optimal absorber. Copyright © 2002 John Wiley & Sons, Ltd.  相似文献   

17.
Passive energy dissipation devices (EDDs), such as viscous dampers, viscoelastic dampers, etc., have been used to effectively reduce the dynamic response of civil infrastructures, such as buildings and bridges, subject to earthquakes and strong winds. The design of these passive energy dissipation devices (EDDs) involves the determination of the optimal locations and the corresponding capacities. In this paper, we present two optimal design methodologies for passive EDDs based on active control theories, including H and H2 performances, respectively. The optimal design methodologies presented are capable of determining the optimal locations and the corresponding capacities of EDDs. Emphasis is placed on the application of linear matrix inequality (LMI) for the effective design of passive EDDs using the popular MATLAB toolboxes. One important advantage of the proposed approaches is that the computation of the structural response is not needed in the design process. The proposed optimal design methodologies have been applied to: (i) a 10‐storey building and a 24‐storey building both subject to earthquake excitations, and (ii) a 76‐storey wind‐excited benchmark building, to demonstrate the advantages of the proposed design methodologies over the conventional equal capacity design. Copyright © 2002 John Wiley & Sons, Ltd.  相似文献   

18.
In this paper, an effective active predictive control algorithm is developed for the vibration control of non-linear hysteretic structural systems subjected to earthquake excitation. The non-linear characteristics of the structural behaviour and the effects of time delay in both the measurements and control action are included throughout the entire analysis (design and validation). This is very important since, in current design practice, structures are assumed to behave non-linearly, and time delays induced by sensors and actuator devices are not avoidable. The proposed algorithm focuses on the instantaneous optimal control approach for the development of a control methodology where the non-linearities are brought into the analysis through a non-linear state vector and a non-linear open-loop term. An autoregressive (AR) model is used to predict the earthquake excitation to be considered in the prediction of the structural response. A performance index that is quadratic in the control force and in the predicted non-linear states, with two additional energy related terms, and that is subjected to a non-linear constraint equation, is minimized at every time step. The effectiveness of the proposed closed-open loop non-linear instantaneous optimal prediction control (CONIOPC) strategy is presented by the results of numerical simulations. Since non-linearity and time-delay effects are incorporated in the mathematical model throughout the derivation of the control methodology, good performance and stability of the controlled structural system are guaranteed. Copyright © 1999 John Wiley & Sons, Ltd.  相似文献   

19.
China is a country where 100% of the territory is located in a seismic zone. Most of the strong earthquakes are over prediction. Most fatalities are caused by structural collapse. Earthquakes not only cause severe damage to structures, but can also damage non-structural elements on and inside of facilities. This can halt city life, and disrupt hospitals, airports, bridges, power plants, and other infrastructure. Designers need to use new techniques to protect structures and facilities inside. Isolation, energy dissipation and, control systems are more and more widely used in recent years in China. Currently, there are nearly 6,500 structures with isolation and about 3,000 structures with passive energy dissipation or hybrid control in China. The mitigation techniques are applied to structures like residential buildings, large or complex structures, bridges, underwater tunnels, historical or cultural relic sites, and industrial facilities, and are used for retrofitting of existed structures. This paper introduces design rules and some new and innovative devices for seismic isolation, energy dissipation and hybrid control for civil and industrial structures. This paper also discusses the development trends for seismic resistance, seismic isolation, passive and active control techniques for the future in China and in the world.  相似文献   

20.
This paper presents an effective optimization technique for the elastic and inelastic drift performance design of reinforced concrete buildings under response spectrum loading and pushover loading. Attempts have been made to develop an automatic optimal elastic and inelastic drift design of concrete framework structures. The entire optimization procedure can be divided into elastic design optimization and inelastic design optimization. Using the principle of virtual work, the elastic drift response generated by the response spectrum loading and the inelastic drift response produced by the non‐linear pushover loading can be explicitly expressed in terms of element sizing design variables. The optimization methodology for the solution of the explicit design problem of buildings is fundamentally based on the Optimality Criteria approach. One ten‐story, two‐bay building frame example is presented to illustrate the effectiveness and practicality of the proposed optimal design method. While rapid convergence in a few design cycles is found in the elastic optimization process, relatively slow but steady and smooth convergence of the optimal performance‐based design is found in the inelastic optimization process. Copyright © 2004 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏