首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Screening level models are now commonly used to estimate vapor intrusion for subsurface volatile organic compounds (VQCs). Significant uncertainty is associated with processes and models and, to date, there has been only limited field-based evaluation of models for this pathway. To address these limitations, a comprehensive evaluation of the Johnson and Ettinger (J&E) model is provided through sensitivity analysis, comparisons of model-predicted to measured vapor intrusion for 11 petroleum hydrocarbon and chlorinated solvent sites, and review of radon and flux chamber studies. Significant intrusion was measured at five of 12 sites with measured vapor attenuation ratios (αm's) (indoor air/source vapor) ranging from ∼1 × 10−6 to 1 × 10−4. Higher attenuation ratios were measured for studies using radon, inert tracers, and flux chambers; however, these ratios are conservative owing to boundary conditions and tracer properties that are different than those at most VOC-contaminated sites. Reasonable predictions were obtained using the J&E model with comparisons indicating that model-predicted vapor attenuation ratios (αp's) were on the same order, or less than the αm's. For several sites, the αm were approximately two orders of magnitude less than the αp's indicating that the J&E model is conservative in these cases. The model comparisons highlight the importance in using appropriate input parameters for the J&E model. The regulatory implications associated with use of the J&E model to derive screening criteria are also discussed.  相似文献   

2.
Screening level models are now commonly used to estimate vapor intrusion for subsurface volatile organic compounds (VOCs). Significant uncertainty is associated with processes and models and, to date, there has been only limited field-based evaluation of models for this pathway. To address these limitations, a comprehensive evaluation of the Johnson and Ettinger (J&E) model is provided through sensitivity analysis, comparisons of model-predicted to measured vapor intrusion for 11 petroleum hydrocarbon and chlorinated solvent sites, and review of radon and flux chamber studies. Significant intrusion was measured at five of 12 sites with measured vapor attenuation ratios (αm's) (indoor air/source vapor) ranging from ∼1 × 10−6 to 1 × 10−4. Higher attenuation ratios were measured for studies using radon, inert tracers, and flux chambers; however, these ratios are conservative owing to boundary conditions and tracer properties that are different than those at most VOC-contaminated sites. Reasonable predictions were obtained using the J&E model with comparisons indicating that model-predicted vapor attenuation ratios (αp's) were on the same order, or less than the αm's. For several sites, the (m were approximately two orders of magnitude less than the a 's indicating that the J&E model is conservative in these cases. The model comparisons highlight the importance in using appropriate input parameters for the J&E model. The regulatory implications associated with use of the J&E model to derive screening criteria are also discussed.  相似文献   

3.
Abstract Self-potential variations were measured to estimate the magnitude of electrokinetic and hydrological parameters (zeta potential and permeability) of the Nojima Fault zone in Awaji, Japan. The study observed self-potential variations that seemed to be associated with water flow from the injection well to the fracture zone, which were induced by turning the injection on and off. Amplitudes of the variations were a few to 0.03 V across 320–450 m dipoles. These variations can be explained well with an electrokinetic model. The quantity k/ζ (permeability/zeta potential) is in the range 1.6 × 10−13− 5.4 × 10−13 m2/V. Permeability of the Nojima fault zone can be estimated as approximately 10−16–10−15 m2 on the assumption that the zeta potential is in the range –0.01 to –0.001 V.  相似文献   

4.
The goal of this study was the cleanup of residual solvents in the saturated zone using an in situ biochemical treatment. Perchloroethylene (PCE) was chosen as a model compound because it is the most commonly found organic ground water contaminant. A mixture of vitamin B12 with titanium citrate was pumped as the remedial solution through a column containing 100 μL of PCE residual. The rate of reaction was found to be first order with respect 10 the concentration of PCE and to the concentration of vitamin B2. At 10 ppm B12, more than 85 percent PCM was degraded to trichloroelhylene (TCE) and dichloroelhylene (DCE) in two hours. The presence of low to moderate concentrations of organic carbon had no significant effect on the reaction. Vitamin B12 reduced by titanium citrate was found lo be compatible with the survival of anaerobic bacteria. The four major advantages of the biochemical system over the use of anaerobic bacteria are that (1) the rate is faster: (2) there is no need for the careful balance of nutrients or the addition of an extraneous carbon source: (3) there is no restriction in the concentration range of the compound to be treated; and (4) the remedial solution is mobile, even in the presence of organic carbon.  相似文献   

5.
Abstract A loam section near Daisen volcano, South-west Japan, has been examined for low-field magnetic susceptibility (MS) and fine quartz accumulation rate. Fission track dating of tephra layers interbedded in the deposit shows that the loam age ranges from about 200 ka to the Present. The MS was measured for both bulk sample and the < 63 μm fine fraction. Fine quartz contents in the < 63 μm fraction were also determined using acid-alkali digestions and recalculated to derive fine quartz accumulation rate (Rqz). Grain size analysis was then carried out on the separated fine quartz. Low-field MS varies from low frequency magnetic suspectibility (χ(LF)) 5 to 100 (× 10−6 m3/kg) for bulk samples and from 1 to 30 for fine fractions. The fine fraction χ(LF) variation correlated with Chinese loess MS stratigraphy, which indicated changes in pedogenic enhancement of the MS and is reflected by summer monsoon intensity. The Rqz are high in cool climate stages, with volumes between 0.2 and 0.4 (× 10−2 kg/m2 per yr), whereas in warm stages the rate falls to about 0.1. These values compare well with those reported from the Hokkaido and Kanto areas, suggesting the fine quartz originates from tropospheric dust. The strong winter monsoons during glacial stages alternated with weak summer monsoons as a result of a southward shift of the jet stream. In interglacials, summer monsoons were stronger. Seasonal alternating monsoons appear to have operated in South-west Japan through the past 200 000 years.  相似文献   

6.
Sharma S  Frost CD 《Ground water》2008,46(2):329-334
Recovery of hydrocarbons commonly is associated with coproduction of water. This water may be put to beneficial use or may be reinjected into subsurface aquifers. In either case, it would be helpful to establish a fingerprint for that coproduced water so that it may be tracked following discharge on the surface or reintroduction to geologic reservoirs. This study explores the potential of using δ13C of dissolved inorganic carbon (DIC) of coalbed natural gas (CBNG)–coproduced water as a fingerprint of its origin and to trace its fate once it is disposed on the surface. Our initial results for water samples coproduced with CBNG from the Powder River Basin show that this water has strongly positive δ13CDIC (12‰ to 22‰) that is readily distinguished from the negative δ13C of most surface and ground water (−8‰ to −11‰). Furthermore, the DIC concentrations in coproduced water samples are also high (more than 100 mg C/L) compared to the 20 to 50 mg C/L in ambient surface and ground water of the region. The distinctively high δ13C and DIC concentrations allow us to identify surface and ground water that have incorporated CBNG-coproduced water. Accordingly, we suggest that the δ13CDIC and DIC concentrations of water can be used for long-term monitoring of infiltration of CBNG-coproduced water into ground water and streams. Our results also show that the δ13CDIC of CBNG-coproduced water from two different coal zones are distinct leading to the possibility of using δ13CDIC to distinguish water produced from different coal zones.  相似文献   

7.
Soil-solution samplers and shallow ground water monitoring wells were utilized to monitor nitrate movement to ground water following H2O2 application to a clogged soil absorption system. Nitrate-nitrogen concentrations in soil water and shallow ground water ranged from 29 to 67 mg/L and 9 to 22 mg/L, respectively, prior to H2O2 treatment. Mean nitrate-nitrogen concentrations in soil water and ground water increased and ranged from 67 to 115 mg/L and 23 to 37 mg/L, respectively, one week after H2O2 application. Elevated concentrations of nitrate-nitrogen above background persisted for several weeks following H2O2 treatment. The H2O2 treatment was unsuccessful in restoring the infiltrative capacity of a well-structured soil. Application of H2O2 to the soil absorption system poses a threat of nitrate contamination of ground water and its usefulness should be fully evaluated before rehabilitation is attempted.  相似文献   

8.
The flow of ponded water into and through the unsaturated zone depends on both the saturated and unsaturated components of the hydraulic conductivity. Recent studies indicate that the ratio of the saturated (Kfs) to the unsaturated (φm) components (Kfsm=α*) of flow lies within prescribed bounds for most field soils, i.e., 1m−1≤α*≤ 100 m−1. In addition, the fact that the calculation of Kfs and φm is not strongly dependent on the choice of α*, suggests that a site estimation of α* leads to reasonable "best estimates" of Kfs and φm when using the constant head well permeameter technique. As a consequence, measurement of the steady flow rate using only one ponded head may be all that is necessary for many practical applications. Multiple head measurements or independent measurements of α* or φm can be used, however, to give more accurate estimates of Kfs if required.  相似文献   

9.
A conceptual model of eolian transport is proposed to address the widely distributed, high concentrations of hexavalent chromium (Cr+6) observed in ground water in the Emirate of Abu Dhabi, United Arab Emirates. Concentrations (30 to more than 1000 μg/L Cr+6) extend over thousands of square kilometers of ground water systems. It is hypothesized that the Cr is derived from weathering of chromium-rich pyroxenes and olivines present in ophiolite sequence of the adjacent Oman (Hajar) Mountains. Cr+3 in the minerals is oxidized to Cr+6 by reduction of manganese and is subsequently sorbed on iron and manganese oxide coatings of particles. When the surfaces of these particles are abraded in this arid environment, they release fine, micrometer-sized, coated particles that are easily transported over large distances by wind and subsequently deposited on the surface. During ground water recharge events, the readily soluble Cr+6 is mobilized by rain water and transported by advective flow into the underlying aquifer. Chromium analyses of ground water, rain, dust, and surface (soil) deposits are consistent with this model, as are electron probe analyses of clasts derived from the eroding Oman ophiolite sequence. Ground water recharge flux is proposed to exercise some control over Cr+6 concentration in the aquifer.  相似文献   

10.
A large number of ground water samples (360) was collected from 60 stations over six consecutive seasons to study the influence of the main sewerage drain on shallow ground water table beneath the municipal area of Cuttack, India. A majority of the samples collected from stations close to the drain exceeded the maximum permissible limits set by the World Health Organization (WHO). Almost all the samples near the drain exceeded the WHO limit for NO3- and Na+. However, the concentrations decreased as the distance from the drain increased. The winter season registered the maximum concentrations of NH4+, NO3-, and SO42- ions whereas the minimum values always coincided with the rainy season. R-mode factor analysis was conducted to find relationships amongst the 16 chemical parameters studied. Fluoride showed a negative correlation with Cl-, Na+, NO3-, SO42-, and PO43-. The concentration of F- may be lower in raw waste water than naturally occurs in the ground water. Therefore, a decrease in the concentration of F- near the drain may be attributed to dilution by contributions of waste water to the ground water. The rest of the parameters were found to be directly related to the distance of collection points to the sewerage. The distribution of nutrients is strongly affected by leaching of waste water into the ground water.  相似文献   

11.
Eloctromigraiion offers a potential tool for remediating ground water contaminated with highly soluble components, such as Na+, Cl, NO3 and SO4. A field experiment was designed to lest the efficacy of electromigration for preconcontrating dissolved SO42 in ground water associated with a fossil-fuel power plant. Two shallow wells, 25 feel apart (one 25 feel deep, the other 47 feet deep), were constructed in the upper portion of an unconfined alluvial aquifer. The wells were constructed with a double-wall design, with an outer casing of 4-inch PVC and an inner lube of 2-inch FVC; both were fully slotted (0.01 inch). Electrodes were constructed by wrapping the inner lulling with a 100-foot length of rare-earth metal oxide/copper wire. An electrical potential of 10.65 volts DC Was applied, and tests were run for periods of 12, 44, and 216 hours. Results showed large changes in the pH from the initial pH of ground water of about 7.5 to values of approximately 2 and 12 at the anode and cathode, respectively. Despite the fact that the test conditions were far from ideal, dissolved SO42-; was significantly concentrated at the anode. Over a period of approximately nine days, the concentration of SO42- at the anode reached what appeared to he a steady-state value of 2200 mg/L. compared lo the initial value in ground water of approximately 1150 mg/L. The results of this field lest should encourage further investigation of electromigration as a tool in the remediation of contaminated ground water.  相似文献   

12.
Machida I  Lee SH 《Ground water》2008,46(4):532-537
We observed long-term changes in the concentrations of dissolved ions in ground water caused by leachate from new volcanic ejecta deposited on the ground surface of the volcanic Miyakejima Island, Japan. Water samples were collected from nine wells and two rain collectors over a period of more than 10 years, and samples of runoff water were collected periodically. The samples were analyzed for temperature, pH, alkalinity, Cl, and SO42−; some of the samples were also analyzed for δ13C. Because the leachate from the volcanic ejecta contained sulfate, we recorded an increase in SO42 concentrations in the (unconfined) well water. The increase in SO42 was initially detected between less than 1.4 and 5.2 years after the eruption, showing peak concentrations from 2.4 to 6.4 years after the eruption. This delayed response reflects the transit time of downward-moving SO42 in the vadose zone, corresponding to an apparent movement rate of 0.4 to 7.2 cm/d. The rate relates to the mean recharge, represented as a fraction of local mean rainfall, and is calculated using the Cl balance method. The magnitude of the recorded increases reflects the volume of volcanic mudflow on the ground surface within the basin. For the management of ground water after an eruption, it is therefore important to know the chemical properties of the volcanic ejecta and the spatial distribution of mudflow to estimate the magnitude of the effect of ejecta on ground water quality.  相似文献   

13.
Abstract Elemental and isotopic compositions of noble gases extracted from the bore hole water in Osaka plain, central Japan were examined. The water samples were collected from four shallow bore holes (180-450 m) and seven deep bore holes (600-1370 m) which have been used for an urban resort hot spring zone. The water temperatures of the deep bore holes were 22-50°C and that of the shallow bore holes, 13-23°C. The elemental abundance patterns show the progressive enrichment of the heavier noble gases compared with the atmospheric noble gas composition except for He, which is heavily enriched in deep bore hole water samples. 3He/4He ratios from the bore holes reaching the Ryoke granitic basement were higher than the atmospheric value (1.4 × 10−6), indicating a release of mantle He through the basement. The highest value of 8.2 × 10−6 is in the range of arc volcanism. On the other hand, the bore holes in sedimentary rocks overlying the basement release He enriched in radiogenic 4He, resulted in a low 3He/4He ratio of 0.5 × 10−6. 4He/20Ne and 40Ar/36Ar ratios indicate that the air contamination is generally larger in shallow bore holes than in deep ones from each site. The helium enriched in mantle He is compatible with the previous work which suggested up-rising magma in 'Kinki Spot', the area of Osaka and western Wakayama, in spite of no volcanic activity in the area. A model to explain an initiation of magma generation beneath this area is presented.  相似文献   

14.
Studies have shown that materials, such us polytetra-fluoroethylene (PTFE), rigid polyvinyl chloride (rigid PVC). flexible polyvinyl chloride (flexible PVC), stainless steel (SS). low-density polyethylene (LDPE), and high-density polyethylene (HDPE), have the potential to influence certain analyte concentrations in ground water samples. The effects of HDPE, LDPE, PTFE, rigid PVC, and SS on aqueous concentrations of nitrate-N, atrazine, deethylatrazine (DEA), and deisopropylatrazine (DIA) were evaluated in a field study A laboratory study was conducted to evaluate sorption of atrazine DEA, DIA, cyanazine, alachlor, metolachlor, and butachlor to PTFE, HDPE, and SS materials. Butachlor is rarely use in the United States, but was included because of its expected high sorptivity. No significant differences between HDPE, LDPE, PTFE, rigid PVC, and SS were determined for any of the analytes tested in the field study. In the laboratory study, sorption of DIA to PTFE and SS was significant at 2.6 × 10−5 and 4.1 × 10−5μg/m2 respectively. Sorption of DIAA to HDPE was not significantly > 0 sorption of all other compounds to HDPE, PTFE, and SS were also not significantly >0. Results of the two studies indicate that for these analytes (relatively polar or ionized compounds), representative ground water samples are not dependent on the materials used for multilevel sampler construction. When considering these compounds, it appears that the least expensive materials (HDPE, rigid PVC, and LDPE) are good choices for the construction of ground water monitoring wells.  相似文献   

15.
A 5-year-old wood particle reactor treating agricultural tile drainage in southern Ontario was monitored for its ongoing ability to treat both nitrate (NO3) and perchlorate (ClO4). Prior to sampling undertaken in the fifth year of operation, a highway safety flare containing ClO4 was immersed in the inlet pipe elevating influent ClO4 concentrations to up to 33.7 μg/L. ClO4 removal rates were inhibited in the presence of more than 1 to 2 mg/L NO3-N, but increased rapidly to about 60 μg/L/d upon NO3 depletion. Nitrate removal rates, measured subsequently in the sixth and seventh years of operation, varied with temperature in the range of 2 to 16 mg N/L/d, but remained similar to rates measured in the second year. Additionally, no deterioration in the hydraulic conductivity (K) of the coarse core layer (0.5 3 removal rates and can remain highly permeable over a number of years. The media can also provide high removal rates for other redox sensitive contaminants such as ClO4. The ability to directly measure the reactor flow rate, in this case via an outlet pipe, greatly simplified the task of estimating hydraulic properties and reaction rates.  相似文献   

16.
Hydraulic conductivity values computed using the steady-state discharge and drawdown attained while low-flow sampling were evaluated to determine if they were equivalent to those determined from slug testing. Based on testing 12 wells, it was found that the results were statistically equivalent. Conductivity values computed using low-flow sampling parameters were also evaluated as to their reproducibility in actual practice by analyzing consultant data for three wells sampled over three quarterly monitoring periods by four field technicians. The results were found to be reproducible within about a factor of 2 or better. Since the method is based on only one pair of parameters, diligence is required in attaining steady state and in accurately measuring the flow rate and drawdown. Conductivity values computed using this approach can enhance the use of low-flow data gathered in water quality sampling, avoid the need for slug testing in a subsequent phase of investigation, and help reduce the cost of characterizing sites when multilevel samplers are used. Given the practical range of discharge in low-flow sampling, the method was found to be applicable at conductivity values somewhat greater than 10−6 cm/s. Given the typical accuracy of water level meters and pressure transducers and a maximum discharge of 1 L/min, as mandated by regulatory guidance, the method has a calculated upper conductivity limit in the range of 10−3 to 10−2 cm/s.  相似文献   

17.
Geographical distribution of helium isotope ratios in northeastern Japan   总被引:1,自引:0,他引:1  
Keika  Horiguchi  Sadato  Ueki  Yuji  Sano  Naoto  Takahata  Akira  Hasegawa  George  Igarashi 《Island Arc》2010,19(1):60-70
In order to study the precise geographical distribution of helium isotope ratios in northeastern Japan and compare it with geophysical data, we collected 43 gas and water samples from hot and mineral springs in the region where the ratio had never been reported, and measured the 3He/4He and 4He/20Ne ratios of these samples. It was found that the 3He/4He ratios show clear contrasts between the forearc and the back-arc regions in the Tohoku district in northeastern Japan. In the forearc region, the ratios are smaller than 1 RA (1 RA = 1.4 × 10−6; RA means the 3He/4He ratio of the atmosphere). On the other hand, those along the volcanic front and in the back-arc region are apparently higher. Moreover, we found a variation in the 3He/4He ratios along the volcanic front. In Miyagi Prefecture (38–39°N), the ratios range from 2 to 5 RA. On the other hand, the ratios are less than 1 RA in and around the southern border between Iwate and Akita Prefectures (39–39.5°N). Comparing the distribution of helium isotope ratios to results of recent geophysical studies, we found that the features in geographical distribution of helium isotope ratios are similar to those of seismic low-velocity zone distributions and high Qp−1 distributions in the uppermost mantle. These observations strongly suggest that the helium isotope ratios reflect the distribution of melts in the uppermost mantle and are a useful tool for investigating the origin, behavior, and distribution of deep fluids and melts.  相似文献   

18.
Pilot-scale testing of an innovative ground water remediation technology was conducted in a source zone of a trichloroethene-contaminated Superfund site in Tucson, Arizona. The technology is designed to enhance the removal of low-solubility organic contaminants from heterogeneous sedimentary aquifers by using a dual-screened vertical circulation well to inject and extract solutions containing a complexing sugar (hydroxypropyl-beta-cyclodextrin (HPCD]). Prior to initiating the pilot test, tracer tests were conducted to determine hydraulic characteristics of the vertical flow field and to evaluate trichloroethene-elution behavior during water flushing. The pilot test involved injecting approximately 4 m3 of a 20% HPCD solution into the upper screened interval of the well and extracting from the lower screened interval. The results of the pilot test indicate that the cyclodextrin solution increased the rate of trichloroethene removal from the aquifer. The concentrations of trichloroethene in the ground water extracted from the lower screened interval of the well increased by a factor of three (∼750 μg/L) in the presence of the cyclodextrin pulse, compared to concentrations obtained during previous water flushing (∼250 μg/L). Furthermore, the concentration of trichloroethene in water collected from the circulation well under static conditions was reduced to 6% of the levels measured prior to the test.  相似文献   

19.
Groundwater contamination associated with an industrial facility in Utah has led to concerns about potential vapor intrusion into residences outside the facility boundary. Trichloroethylene (TCE) is the main contaminant of concern with 1,2-dichloroethane (1,2-DCA) present in some areas. An air-monitoring program implemented to detect vapor intrusion of these compounds found 1,2-DCA in homes outside areas of groundwater contamination, suggesting indoor sources in these cases. Investigative indoor air and product sampling were conducted to isolate consumer products emitting 1,2-DCA and to quantify the emission rates of identified products. The combination of room-by-room air sampling and emission measurements was successfully used to identify molded plastic holiday ornaments, having measured emission rates as high as 0.3 µg 1,2-DCA/min. Subsequent testing of seven comparable retail items found similar 1,2-DCA emissions. Screening-level calculations show that the measured emission rates of 1,2-DCA from these items can lead to indoor concentrations high enough to be of regulatory concern (0.094 to 9.4 µg/m3 based on 10–6 to 10–4 cancer risk levels).  相似文献   

20.
At a utility service center, gasoline from an underground storage tank had leaked into subsurface vadose zone soils for several years. To remediate the site, a soil vapor extraction (SVE) system was installed and operated. At the completion of the SVE operation, gasoline-containing residues in several confirmation soil borings exceeded agency-mandated cleanup levels. Rather than continue with SVE, a risk-based approach was developed to evaluate what levels of gasoline-containing residues could be left in the soil and still protect human health. The risk-based approach consisted of simulating the fate of chemical residues through the vadose zone and then into both the ground water and atmosphere. Receptor point concentrations were predicted, and health risks were assessed. The risk assessment concluded that ingestion of contaminated ground water and inhalation of air while showering were the largest potential contributors to risk, and that risks associated with inhalation of vapor-containing ambient air are small. However, all predicted risks are below the acceptable risk levels of 10−6 individual cancer risk probability and 1.0 hazard index. Therefore, the lead agency accepted the recommendation that the site requires no further remediation. The service center continues normal operations today.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号