首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 21 毫秒
1.
Summary During the Hartheim Experiment (HartX) 1992 conducted in the Upper Rhine Valley, Germany, we estimated water vapor flux from the understory and the forest floor by several methods. At the vegetation patch level, direct estimates were made with small weighing lysimeters, and water loss was scaled-up to the stand level based on vegetation patchtype distribution. At the leaf level, transpiration flux was determined with a CO2/H2O porometer for the dominant understory plant species,Brachypodium pinnatum, Carex alba, andCarex flacca. Measured leaf transpiration was scaled-up to patch level with a canopy light interception and leaf gas exchange model, and then to stand level as in the case of lysimeter data, but with further consideration of patchtype leaf area index (LAI). On two days, total understory latent heat flux was estimated by eddy correlation methods below the tree canopy.The understory vegetation was subdivided into five major patch-types which covered 62% of the ground area and resulted in a cumulative LAI of approx. 1.54 when averaged over total stand ground area and compared to the average tree canopy LAI of 2.8. The remaining 38% of ground area was unvegetated bare soil and/or covered by moss (mainly byScleropodium purum) or litter. The evapotranspiration from the understory and unvegetated areas equaled approx. 20% of total forest stand transpiration during the HartX period. The understory vegetation transpired about 0.4 mm d–1 (13%) estimated over the period of May 13 to 21, whereas evaporation from moss and soil patches amounted 0.23 mm d–1 (7.0%). On dry, sunny days, total water vapor flux below the tree canopy exceeded 0.66 mm d–1. Using the transpiration rates derived from the GAS-FLUX model together with estimates of evaporation from moss and soil areas and a modified application of the Penman-Monteith equation, the average daily maximum conductance of the understory and the forest floor was 1.7 mm s–1 as compared to 5.5 mm s–1 for the tree canopy.With 6 Figures  相似文献   

2.
Summary A single layer (Penman-Monteith) and a two layer (modified Shuttleworth-Wallace) evapotranspiration (ET) model are used alternatively to derive conductances related to the dominant fluxes of water vapor from a semi-closed Scots pine plantation. The derivations are based on micrometeorological measurements of above canopy energy flux densities and a simple resistance network. For a period of consecutive fine weather days, below canopy net radiation and below canopy ET were about 20 percent of the corresponding above canopy values. Resulting conductances for latent heat flux agreed well with porometric measurements of pines and understory scaled to canopy level. The shift from single to two layer modelling reduced the canopy conductance to pine conductance by the fraction of understory ET.However, characteristics of porometer results and micrometeorologically derived conductances were quite different: The porometer estimates of conductance were highly variable due to stomatal response to local environmental conditions or natural variability within the tree canopy and vegetation patches which characterized the forest understory. Micrometeorologically derived conductances integrate spatially resulting in relatively smooth and repetitive daily patterns that lack the information of small scale variability. This is seen as a favorable feature of micrometeorological derived conductances when used for the parameterization of atmospheric models for climate research as long as small scale bio-diversity is irrelevant.With 5 Figures  相似文献   

3.
Summary During the Hartheim experiment (HartX) 1992, conducted in the Upper Rhine Valley, Germany, we estimated water vapor flux from the understory by several methods as reported in Wedler et al. (this issue). We also examined the photosynthetic gas exchange of the dominant understory speciesBrachypodium pinnatum, Carex alba, andCarex flacca at the leaf level with an CO2/H2O porometer. A mechanisticallybased leaf gas exchange model was parameterized for these understory species and validated via the measured diurnal courses of carbon dioxide exchange. Leaf CO2 gas exchange was scaled-up to patch- and then to stand-level utilizing the leaf gas exchange model as a component of the canopy light interception/energy balance model GAS-FLUX, and by further considering variation in vegetation patch-type distribution, patch-specific spatial structure, patch-type leaf area index, and microclimate beneath the tree canopy.At patch-level,C. alba exhibited the lowest net CO2 uptake of ca. 75 mmol m–2 d–1 due to a low leaf-level photosynthetic capacity, whereas net CO2 fixation ofB. pinnatum- andC. flacca-patches was approx. 178 and 184 mmol m–2 d–1, respectively. Highest CO2 uptake was estimated for mixed patches whereB. pinnatum grew together with the sedge speciesC. alba orC. flacca. Scaling-up of leaf gas exchange to stand level resulted in an estimated average rate of total CO2 fixation by the graminoid understory patches of approximately 93 mmol m–2 d–1 during the HartX period. The conservative gas exchange behavior ofC. alba at Hartheim and its apparent success in space capture seems to affect overall functioning of this pine forest ecosystem by limiting understory CO2 uptake. The CO2 uptake by the understory is approximately 20% of stand total CO2 uptake. CO2 uptake fluxes mirror the relative differences in water loss from the understory and crown layer during the HartX period. Comparative measurements indicate that understory vegetation in spruce and pine forests is not greatly different from that of other low-statured natural ecosystems such as tundra or marshes under high light conditions, although CO2 capture by the understory at Hartheim is at the low extreme of the estimates, apparently due to the success ofC. alba. With 6 Figures  相似文献   

4.
Summary  Tree canopy water use and foliage net CO2 uptake (NPP) were simulated for a 31-year-old Pinus sylvestris (Scots pine) plantation near Hartheim, in the Upper Rhine Valley, Germany with a mechanistically-based, three-dimensional stand gas-exchange model (STANDFLUX) for a ten-day period during spring 1992. STANDFLUX was formulated to include the effects of penumbra caused by the fine structure of the needles on light distribution within crowns. Good correspondence was found between simulated rates of tree canopy water use when including penumbral effects and eddy-covariance ET and sap flow transpiration measurements. Water use was 8–13% lower and NPP was 10–17% lower in simulations for the ten-day period when penumbral effects were not included. Simulated water use and CO2 uptake were compared with similar outputs from a simplified layer canopy model (including or not including penumbra) which assumed horizontal homogeneity in canopy structure (GAS FLUX). Our results for the Pinus sylvestris stand indicate that penumbral effects were more important than the degree of model simplification with respect to foliage distribution (three-dimensional vs. layered structure) for estimating stand-level fluxes for these pines. Simulated maximum hourly NPP was similar to rates measured for other Pinus sylvestris stands using other methods. Predicted decreases in tree transpiration due to the modelled response of needle gas exchange to increasing vapour-pressure deficit agreed with measured changes in transpiration, and suggested that stomatal response may have been more important than decreasing soil water availability in controlling water flux to the atmosphere during this period. The overall results of the study demonstrate that current approaches in canopy modelling that separate light into sun versus shade intensities can be effective, but must be applied with caution when attempting to predict long-term water and carbon balances of forests. Received May 1, 1999 Revised November 9, 2000  相似文献   

5.
Summary During two measurement campaigns in 1992 (the Hartheim Experiment HartX- and an additional experiment in autumn), measurements of soil moisture were carried out in aPinus sylvestris stand at Hartheim on the Oberrhein. Several methods were used to determine soil water status. They were compared in terms of suitability for estimating stand evapotranspiration (ET) via soil water depletion. Measurements of tree water potential suggested that conductance of the trees was affected by soil water depletion during the period of the HartX campaign in spring 1992. We interpret the observations to indicate a lesser influence of soil water availability on tree transpiration during the autumn experiment.Eddy correlation and xylem sapflow measurements provided reference ET values with which to compare the stand ET calculations based on soil moisture measurements. Profile measurements of soil moisture showed that particularly in springtime when the lower soil layers are saturated with water, the water transport from depths below the major rooting zone is a very important factor affecting evaluation of stand ET. Decreases in soil water storage may be determined best with permanently installed soil moisture sensors such as used in tensiometric or TDR measurements that provide high resolution of changes over time.With 8 Figures  相似文献   

6.
Summary The experimental site of the Department of Meteorology of Freiburg University at the Hartheim pine stand is first described. There, since 1973 long term measurements of net radiation and its components have been carried out. In addition we have been monitoring the different heat fluxes and components of the forest water budget.From May 11th to May 24th 1992 a special international and interdisciplinary observation period was organized in Hartheim (HartX 92). This took place in the frame of the international regional climatic project REKLIP (Regionales Klima Projekt). We then describe the permanent equipment and the special HartX installations. After that we show the climate of the region, in May 1992 and the weather during the HartX period. It was extraordinarily warm and the precipitation was much less than normal. The cloud cover was very small.We report the results of the radiation measurements (net radiation and its components). They are compared to the long standing measurements (1974–1988). Moreover the longstanding data of the components of the water budget (throughfall, canopy drip and stemflow, interception and transpiration) of the period 1978–1985 are dealt with. In addition we report the behaviour of the energy fluxes (soil-stand heat flux, turbulent sensible and latent heat fluxes) of the period 1974–1988. These estimations are compared to the conditions in May 1992 and the conditions during HartX 92.With 8 Figures  相似文献   

7.
Summary Simultaneous measurements of xylem sap flow and water vapour flux over a Scots pine (Pinus sylvestris) forest (Hartheim, Germany), were carried out during the Hartheim Experiment (HartX), an intensive observation campaign of the international programme REKLIP. Sap flow was measured every 30 min using both radial constant heating (Granier, 1985) and two types of Cermak sap flowmeters installed on 24 trees selected to cover a wide range of the diameter classes of the stand (min 8 cm; max 17.5 cm). Available energy was high during the observation period (5.5 to 6.9 mm.day–1), and daily cumulated sap flow on a ground area basis varied between 2.0 and 2.7 mm day–1 depending on climate conditions. Maximum hourly values of sap flow reached 0.33 mm h–1, i.e., 230 W m–2.Comparisons of sap flow with water vapour flux as measured with two OPEC (One Propeller Eddy Correlation, University of Arizona) systems showed a time lag between the two methods, sap flow lagging about 90 min behind vapour flux. After taking into account this time lag in the sap flow data set, a good agreement was found between both methods: sap flow = 0.745* vapour flux,r 2 = 0.86. The difference between the two estimates was due to understory transpiration.Canopy conductance (g c ) was calculated from sap flow measurements using the reverse form of Penman-Monteith equation and climatic data measured 4 m above the canopy. Variations ofg c were well correlated (r 2 = 0.85) with global radiation (R) and vapour pressure deficit (vpd). The quantitative expression forg c =f (R, vpd) was very similar to that previously found with maritime pine (Pinus pinaster) in the forest of Les Landes, South Western France.With 6 Figures  相似文献   

8.
Summary This paper describes measurements of the Hartheim forest energy budget for the 157-day period of May 11 – Oct. 14, 1992. Data were collected as 30-min means. Energy available to the forest was measured with net radiometers and soil heat flux discs; sensible heat exchange between the canopy and atmosphere was measured with two One-Propeller Eddy Correlation (OPEC) systems, and latent energy (evapotranspiration orET) was determined as a residual in the surface energy balance equation. Net rediation, change in thermal storage, and sensible heat flux were verified by independent measurements during the Hartheim Experiment (HartX, May 11–12), and again during the HartX2 experiment over 20 days late in the summer (Sep. 10–29). Specifically, sensible heat estimates from the two adjacent OPEC sensor sets were in close agreement throughout the summer, and in excellent agreement with measurements of sonic eddy correlation systems in May and September. The eddy correlation/energy balance technique was observed to overestimate occurrence of dew, leading to an underestimate of dailyET of about 5%. After taking dew into account, estimates of OPECET totaled 358 mm over the 5.1-month period, which is in quite good agreement with an ET estimate of 328 mm from a hydrologic water balance. An observed decrease in forestET in July and August was clearly associated with low rainfall and increased soil water deficit. The OPEC system required only modest technical supervision, and generated a data yield of 99.5% over the period DOY 144–288. The documented verification and precision of this energy budget appears to be unmatched by any other long-term forest study reported to date.With 9 Figures  相似文献   

9.
Seasonal drought is a common occurrence in humid climates.The year 2003 was the driest year during the period 1985-2011 in southeastern China.The objective of this study was to elucidate the impact of the exceptional drought in 2003,compared with eddy flux measurements during 2004-11,on the dynamics of evapotranspiration (ET) and related factors,as well as their underlying mechanisms,in a subtropical coniferous plantation in southeastern China.It was found that daily ET decreased from 5.34 to 1.84 mm during the intensive drought period and recovered to 4.80 mm during the subsquent recovering drought period.Path analysis indicated that ET was mainly determined by canopy conductance and deep soil water content (50 cm) during the intensive drought and recovering drought periods,respectively.The canopy conductance offset the positive effect of air vapor pressure deficit on ET when suffering drought stress,while the canopy conductance enhanced the positive effect of air temperature on ET during the late growing season.Because the fine roots of this plantation are mainly distributed in shallow soil,and the soil water in the upper 40 cm did not satisfy the demand for ET,stomatal closure and defoliation were evident as physiological responses to drought stress.  相似文献   

10.
The Validity of Similarity Theory in the Roughness Sublayer Above Forests   总被引:1,自引:0,他引:1  
Flux-gradient relationships based upon similarity theory have been reported to severely underestimate scalar fluxes in the roughness sublayer above forests, as compared to independent flux estimates (for example, eddy covariance or energy balance measurements). This paper presents the results of a unique three-month investigation into the validity of similarity theory in the roughness sublayer above forests. Eddy covariance and flux-gradient measurements of carbon dioxide (CO2) exchange were compared above a mixed deciduous forest at Camp Borden, Ontario, both before and after leaf senescence. The eddy covariance measurements used a Li-Cor infrared gas analyzer, and the flux-gradient (similarity theory) measurements featured a tunable diode laser Trace Gas Analysis System (TGAS). The TGAS resolved the CO2 concentration difference to 300 parts per trillion by volume (ppt) based upon a half-hour sampling period. The measured enhancement factor (the ratio of independent flux estimates, in this case eddy covariance, to similarity theory fluxes) was smaller and occurred closer to the canopy than in most previous investigations of similarity theory. Very good agreement between the eddy covariance and similarity theory fluxes was found between 1.9 and 2.2 canopy heights (hc), and the mean enhancement factors measured before and after leaf senescence were 1.10 plusmn; 0.06 and 1.24 ± 0.07, respectively. Larger discrepancies were measured closer to the canopy (1.2 to 1.4 hc), and mean enhancement factors of 1.60 ± 0.10 and 1.82 ± 0.11 were measured before and after leaf senescence, respectively. Overall, the Borden results suggest that similarity theory can be used within the roughness sublayer with a greater confidence than previously has been believed.  相似文献   

11.
This paper describes the application of the variance method for flux estimation over a mixed agricultural region in China. Eddy covariance and flux variance measurements were conducted in a near-surface layer over a non-uniform land surface in the central plain of China from 7 June to 20 July 2002. During this period, the mean canopy height was about 0.50 m. The study site consisted of grass (10% of area), beans (15%), corn (15%) and rice (60%). Under unstable conditions, the standard deviations of temperature and water vapor density (normalized by appropriate scaling parameters), observed by a single instrument, followed the Monin-Obukhov similarity theory. The similarity constants for heat (CT ) and water vapor (Cq) were 1.09 and 1.49, respectively. In comparison with direct measurements using eddy covariance techniques, the flux variance method, on average, underestimated sensible heat flux by 21% and latent heat flux by 24%, which may be attributed to the fact that the observed slight deviations (20% or 30% at most) of the similarity “constants” may be within the expected range of variation of a single instrument from the generally-valid relations.  相似文献   

12.
We assessed in absolute and relative terms how solar radiation and water vapour pressure deficit control the latent heat flux density in a Scots pine (Pinus sylvestris L.) forest growing under boreal conditions. The absolute and relative total control can be expressed as sums of the physical and biological forms of control. Physical control is based on the direct effects of solar radiation and water vapour pressure deficit on latent heat flux density, and biological control on the effects of solar radiation and water vapour pressure deficit on latent heat flux density through surface resistance. Measurements based on the eddy covariance method were used in the assessment, which defined the scale adopted in the study. Relative physical control over latent heat flux density was mainly exercised by water vapour pressure deficit, and the role of solar radiation was only marginal. The relative biological control exercised by solar radiation over latent heat flux density was higher in the morning and afternoon, unlike the control exercised by water vapour pressure deficit, which was strongest around noon. The values for the relative total control exercised by solar radiation over latent heat flux density were in general higher than those for relative total control exercised by water vapour pressure deficit. This is inconsistent with expectations based on Omega theory, where a decoupling coefficient () indicates the relative control exercised by surface resistance over latent heat flux density. Solar radiation and water vapour pressure deficit do not necessarily act in opposite directions in the absolute or relative total control that they maintain over latent heat flux density.  相似文献   

13.
Summary Remote sensing and ground measurements were used to evaluate the homogeneity of the Scots pine plantation of Hartheim and the interactions between the forest and its surroundings during HartX.Remote sensing data contribute to characterization of the Scots pine plantation of Hartheim in terms of surface properties and thermal and biological characteristics of the forest. The surroundings of the main experiment site in the forest has homogenous normalized difference vegetation index, microwave specle and brightness temperatures to all directions for at least 500 m. Local sensible heat flux estimates using satellite measured brightness temperatures andin situ measured wind and air temperatures showed good agreement.On some days during HartX the test area was influenced by advection of dry air from the northern Upper Rhine Valley. Agricultural surroundings close to the forest are influenced by breezes flowing out of the forest during radiative nights with weak large-scale motion.With 7 Figures  相似文献   

14.
Estimates of hourly transpiration from a 16–17 yr old Sitka spruce forest were calculated from the Penman-Monteith combination equation and compared with estimates from an eddy correlation/energy balance method.Canopy conductances were estimated from stomatal conductances measured using null balance diffusion porometers and took account of canopy variations of stomatal conductance and needle area index.Vertical heat fluxes were measured by the eddy correlation method; transpiration fluxes were then estimated from an energy balance of the forest.There was not a 1:1 relationship between the estimates of transpiration from the two methods. The major sources of error were concluded to be (i) difficulties of estimating the variation in stomatal conductance and leaf area through the canopy, (ii) errors in the value of total leaf area index, and (iii) errors in stomatal conductance measurements.The eddy correlation method was suggested as the more useful for future studies of the variation of forest transpiration in time or space, because the Penman-Monteith equation requires extensive biological measurements.  相似文献   

15.
This is the second paper describing a study of the turbulence regimes and exchange processes within and above an extensive Douglas-fir stand. The experiment was conducted on Vancouver Island during a two-week rainless period in July and August 1990. Two eddy correlation units were operated in the daytime to measure the fluxes of sensible heat and water vapour and other turbulence statistics at various heights within and above the stand. Net radiation was measured above the overstory using a stationary net radiometer and beneath the overstory using a tram system. Supplementary measurements included soil heat flux, humidity above and beneath the overstory, profiles of wind speed and air temperature, and the spatial variation of sensible heat flux near the forest floor.The sum of sensible and latent heat fluxes above the stand accounted for, on average, 83% of the available energy flux. On some days, energy budget closure was far better than on others. The average value of the Bowen ratio was 2.1 above the stand and 1.4 beneath the overstory. The mid-morning value of the canopy resistance was 150–450 s/m during the experiment and mid-day value of the Omega factor was about 0.20. The daytime mean canopy resistance showed a strong dependence on the mean saturation deficit during the two-week experimental period.The sum of sensible and latent heat fluxes beneath the overstory accounted for 74% of the available energy flux beneath the overstory. One of the reasons for this energy imbalance was that the small number of soil heat flux plates and the short pathway of the radiometer tram system was unable to account for the large horizontal heterogeneity in the available energy flux beneath the overstory. On the other hand, good agreement was obtained among the measurements of sensible heat flux made near the forest floor at four positions 15 m apart.There was a constant flux layer in the trunk space, a large flux divergence in the canopy layer, and a constant flux layer above the stand. Counter-gradient flux of sensible heat constantly occurred at the base of the canopy.The transfer of sensible heat and water vapour was dominated by intermittent cool downdraft and warm updraft events and dry downdraft and moist updraft events, respectively, at all levels. For sensible heat flux, the ratio of the contribution of cool downdrafts to that of warm updrafts was greater than one in the canopy layer and less than one above the stand and near the forest floor.  相似文献   

16.
A knowledge of the distribution of the contribution of upwind sources to measurements of vertical scalar flux densities is important for the correct interpretation of eddy covariance data. Several approaches have been developed to estimate this so-called footprint function. Here a new approach based on the ensemble-averaged Navier—Stokes equations is presented. Comparisons of numerical results using this approach with results from other studies under a range of environmental conditions show that the model predictions are robust. Moreover, the approach outlined here has the advantage of a potential wide applicability, due to an ability to take into account the heterogeneous nature of underlying surfaces. For example, the model showed that any variations in surface drag, such as must occur in real life heterogeneous canopies, can exert a marked influence of the shape and extent of flux footprints. Indeed, it seems likely that under such circumstances, estimates of surface fluxes will be weighted towards areas of highest foliage density (and therefore quite likely higher photosynthetic rates) close to the measurement sensor. Three-dimensional footprints during the day and night were also determined for a mixed coniferous forest in european Russia. A marked asymmetry of the footprint in the crosswind direction was observed, this being especially pronounced for non-uniform plant distributions involving vegetation types with different morphological and physiological properties. The model also found that, other things being equal, the footprint peak for forest soil respiration is typically over twice the distance from the above canopy measurement sensor compared to that for canopy photosynthesis. This result has important consequences for the interpretation of annual ecosystem carbon balances by the eddy covariance method.  相似文献   

17.
陆地蒸散(ET)涵括地表和潮湿叶片的蒸发和植物的蒸散发,是陆地水循环的重要组成部分。Penman-Monteith方程是估算陆地蒸散的重要方法,方程中的叶片或冠层气孔导度是提高估算精度的关键因子。根据碳水循环的耦合原理,植物光合作用模型可用于估算叶片或冠层气孔导度。植物光合作用模型可分为三类:1)使用总冠层导度的大叶模型(BL),2)区别阴、阳叶冠层导度的双大叶模型(TBL),3)区别阴、阳叶叶片导度的双叶模型(TL)。与这三类光合作用模型相对应,衍生出基于不同导度计算方法的三种蒸散估算模型。三种蒸散模型之间的主要区别在于是否进行从叶片尺度到冠层尺度的气孔导度集成。这三种模型中,双叶模型使用叶片尺度的气孔导度,集成度最低。反之,大叶模型使用冠层尺度的气孔导度,集成度最高。由于在Penman-Monteith中,蒸腾和气孔导度之间的关系是非线性的,气孔导度的集合会导致负偏差。因此,与通量测量相比,大叶蒸散模型的估算偏差最大,而双叶蒸散模型的估算偏差最小。  相似文献   

18.
Insect outbreaks are major disturbances that affect a land area similar to that of forest fires across North America. The recent mountain pine bark beetle (D endroctonus ponderosae) outbreak and its associated blue stain fungi (Grosmannia clavigera) are impacting water partitioning processes of forests in the Rocky Mountain region as the spatially heterogeneous disturbance spreads across the landscape. Water cycling may dramatically change due to increasing spatial heterogeneity from uneven mortality. Water and energy storage within trees and soils may also decrease, due to hydraulic failure and mortality caused by blue stain fungi followed by shifts in the water budget. This forest disturbance was unique in comparison to fire or timber harvesting because water fluxes were altered before significant structural change occurred to the canopy. We investigated the impacts of bark beetles on lodgepole pine (Pinus contorta) stand and ecosystem level hydrologic processes and the resulting vertical and horizontal spatial variability in energy storage. Bark beetle-impacted stands had on average 57 % higher soil moisture, 1.5 °C higher soil temperature, and 0.8 °C higher tree bole temperature over four growing seasons compared to unimpacted stands. Seasonal latent heat flux was highly correlated with soil moisture. Thus, high mortality levels led to an increase in ecosystem level Bowen ratio as sensible heat fluxes increased yearly and latent heat fluxes varied with soil moisture levels. Decline in canopy biomass (leaf, stem, and branch) was not seen, but ground-to-atmosphere longwave radiation flux increased, as the ground surface was a larger component of the longwave radiation. Variability in soil, latent, and sensible heat flux and radiation measurements increased during the disturbance. Accounting for stand level variability in water and energy fluxes will provide a method to quantify potential drivers of ecosystem processes and services as well as lead to greater confidence in measurements for all dynamic disturbances.  相似文献   

19.
Regional estimates of evapotranspiration (ET) are critical for a wide range of applications. Satellite remote sensing is a promising tool for obtaining reasonable ET spatial distribution data. However, there are at least two major problems that exist in the regional estimation of ET from remote sensing data. One is the conflicting requirements of simple data over a wide region, and accuracy of those data. The second is the lack of regional ET products that cover the entire region of northern China. In this study, we first retrieved the evaporative fraction (EF) by interpolating from the difference of day/night land surface temperature ( T ) and the normalized difference vegetation index (NDVI) triangular-shaped scatter space. Then, ET was generated from EF and land surface meteorological data. The estimated eight-day EF and ET results were validated with 14 eddy covariance (EC) flux measurements in the growing season (July-September) for the year2008 over the study area. The estimated values agreed well with flux tower measurements, and this agreement was highly statistically significant for both EF and ET (p <0.01), with the correlation coefficient for EF (R2 =0.64) being relatively higher than for ET (R2 =0.57). Validation with EC-measured ET showed the mean RMSE and bias were 0.78 mm d-1 (22.03 W m-2 ) and 0.31 mm d-1 (8.86 W m-2 ), respectively. The ET over the study area increased along a clear longitudinal gradient, which was probably controlled by the gradient of precipitation, green vegetation fractions, and the intensity of human activities. The satellite-based estimates adequately captured the spatial and seasonal structure of ET. Overall, our results demonstrate the potential of this simple but practical method for monitoring ET over regions with heterogeneous surface areas.  相似文献   

20.
Summary Energy balance components over a grassland surface were compared to those obtained above an adjacent, uniform Scots pine plantation during a five-day period of fine, sunny, spring weather. Soils were judged to contain ample water. Shortwave and total radiation flux densities were measured at both sites with pyranometers and total pyrradiometers. Soil heat flux densities were measured with heat flux plates at both sites, and additional storage changes were estimated for air and canopy at the forest site. The forest gained more shortwave energy than the grassland during daytime because of its lower albedo, but it lost more longwave radiation at night. The turbulent fluxes of sensible and latent energy were evaluated with the Bowen ratio energy balance (BREB) method at both sites. Temperature and humidity gradients were measured with fixed psychrometers at the grassland site, and with interchanging psychrometers at the forest site. Mean daily evapotranspiration (ET) averaged 2.26 mm over the five days for the Scots pine, or only 57 percent of the 3.94 mm measured at the grassland site. The mean Bowen ratios were 2.6 and 0.8, respectively.An error analysis was carried out for the BREB estimates of latent heat flux at the two sites. For a given error in latent heat flux and at a specified Bowen ratio the demands on accuracy of dry- and wet-bulb temperature gradients above the rough forest canopy was found to be 10 times higher than above the smoother grassland. If additionally the observed differences in transpiration rates between the two sites were taken into account, the precision for temperature gradient measurements above the slowly transpiring forest becomes fortyfold greater than required above the rapidly transpiring grass. At present, BREB precision requirements for gradients above rougher, drier canopies appear achievable only through use of specialized instrumentation, such as measurement systems that incorporate interchangeable psychrometers into their design.With 9 Figures  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号