首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 66 毫秒
1.
Hazardous waste site investigations have shown that volatile organic compounds (VOCs) can be transported via sewer pipes and migrate into indoor spaces. Despite field data confirming the presence of this exposure pathway, there is lack of context-based numerical models that provide guidance to characterize and predict VOCs concentration in sewer gas at vapor intrusion sites. Particularly, this poses a challenge when assessing and mitigating risks associated with these exposure pathways. Therefore, a numerical model has been developed to simulate the concentration of VOCs in sewer gas in different stages throughout the sewer lines. The developed model considers various input parameters, including temperature, sewer liquid depth, groundwater depth, and sewer construction characteristics to incorporate local and operational conditions. The model's output is verified using field data from a sewer system constructed near a Superfund site. Moreover, a sensitivity analysis was conducted to evaluate the model's response to variation of the external input parameters. To the best of our knowledge, this study is the first attempt to model VOCs concentration in sewer gas, particularly to address vapor intrusion. The developed model can be used as a numerical tool to support the development of sewer assessment guidelines, risk assessment studies, and mitigation strategies.  相似文献   

2.
The United States Environmental Protection Agency (USEPA) is finalizing its vapor intrusion guidelines. One of the important issues related to vapor intrusion is background concentrations of volatile organic compounds (VOCs) in indoor air, typically attributed to consumer products and building materials. Background concentrations can exist even in the absence of vapor intrusion and are an important consideration when conducting site assessments. In addition, the development of accurate conceptual models that depict pathways for vapor entry into buildings is important during vapor intrusion site assessments. Sewer gas, either as a contributor to background concentrations or as part of the site conceptual model, is not routinely evaluated during vapor intrusion site assessments. The research described herein identifies an instance where vapors emanating directly from a sanitary sewer pipe within a residence were determined to be a source of tetrachloroethylene (PCE) detected in indoor air. Concentrations of PCE in the bathroom range from 2.1 to 190 µg/m3 and exceed typical indoor air concentrations by orders of magnitude resulting in human health risk classified as an “Imminent Hazard” condition. The results suggest that infiltration of sewer gas resulted in PCE concentrations in indoor air that were nearly two orders of magnitude higher as compared to when infiltration of sewer gas was not known to be occurring. This previously understudied pathway whereby sewers serve as sources of PCE (and potentially other VOC) vapors is highlighted. Implications for vapor intrusion investigations are also discussed.  相似文献   

3.
Sewer inlet structures are vital components of urban drainage systems and their operational conditions can largely affect the overall performance of the system. However, their hydraulic behaviour and the way in which it is affected by clogging is often overlooked in urban drainage models, thus leading to misrepresentation of system performance and, in particular, of flooding occurrence. In the present paper, a novel methodology is proposed to stochastically model stormwater urban drainage systems, taking the impact of sewer inlet operational conditions (e.g. clogging due to debris accumulation) on urban pluvial flooding into account. The proposed methodology comprises three main steps: (i) identification of sewer inlets most prone to clogging based upon a spatial analysis of their proximity to trees and evaluation of sewer inlet locations; (ii) Monte Carlo simulation of the capacity of inlets prone to clogging and subsequent simulation of flooding for each sewer inlet capacity scenario, and (iii) delineation of stochastic flood hazard maps. The proposed methodology was demonstrated using as case study design storms as well as two real storm events observed in the city of Coimbra (Portugal), which reportedly led to flooding in different areas of the catchment. The results show that sewer inlet capacity can indeed have a large impact on the occurrence of urban pluvial flooding and that it is essential to account for variations in sewer inlet capacity in urban drainage models. Overall, the stochastic methodology proposed in this study constitutes a useful tool for dealing with uncertainties in sewer inlet operational conditions and, as compared to more traditional deterministic approaches, it allows a more comprehensive assessment of urban pluvial flood hazard, which in turn enables better-informed flood risk assessment and management decisions.  相似文献   

4.
Performing a comprehensive risk analysis is primordial to ensure a reliable and sustainable water supply. Though the general framework of risk analysis is well established, specific adaptation seems needed for systems such as water distribution networks (WDN). Understanding of vulnerabilities of WDN against deliberate contamination and consumers’ sensitivity against contaminated water use is very vital to inform decision-maker. This paper presents an innovative step-by-step methodology for developing comprehensive indicators to perform sensitivity, vulnerability and criticality analyses in case of absence of early warning system (EWS). The assessment and the aggregation of these indicators with specific fuzzy operators allow identifying the most critical points in a WDN. Intentional intrusion of contaminants at these points can potentially harm both the consumers as well as water infrastructure. The implementation of the developed methodology has been demonstrated through a case study of a French WDN unequipped with sensors.  相似文献   

5.
Vapor intrusion pathway evaluations commonly begin with a comparison of volatile organic chemical (VOC) concentrations in groundwater to generic, or Tier 1, screening levels. These screening levels are typically quite low reflecting both a desired level of conservatism in a generic risk screening process as well as limitations in understanding of physical and chemical processes that impact vapor migration in the subsurface. To study the latter issue, we have collected detailed soil gas and groundwater vertical concentration profiles and evaluated soil characteristics at seven different sites overlying chlorinated solvent contaminant plumes. The goal of the study was to evaluate soil characteristics and their impacts on VOC attenuation from groundwater to deep soil gas (i.e., soil gas in the unsaturated zone within 2 feet of the water table). The study results suggest that generic screening levels can be adjusted by a factor of 100× at sites with fine‐grained soils above the water table, as identified by visual observations or soil air permeability measurements. For these fine‐grained soil sites, the upward‐adjusted screening levels maintain a level of conservatism while potentially eliminating the need for vapor intrusion investigations at sites that may not meet generic screening criteria.  相似文献   

6.
Abstract

This paper presents a new integrated GIS modelling methodology for assessing groundwater contamination risk. Analytical and numerical tools within a GIS framework were used to define the raster maps of various factors interfering along the contaminant pathway from source to groundwater. In the proposed methodology, these factors were introduced into a unified GIS model for groundwater risk assessment that incorporates all the necessary information to improve the accuracy of the results. Fifteen factors were considered in order to estimate the spatial distribution of the groundwater contamination risk areas. Some of these factors, such as artificial drainage and seepage velocity, had not been used previously in GIS groundwater risk mapping. The study area, the island of Crete in Greece, was divided into five regions characterized by different degrees of groundwater risk ranging from very low to very high. A sensitivity analysis was performed and the developed methodology was validated for different contaminants that were detected in groundwater of the island of Crete.
Editor Z.W. Kundzewicz  相似文献   

7.
A value of 0.001 is recommended by the United States Environmental Protection Agency (USEPA) for its groundwater‐to‐indoor air Generic Attenuation Factor (GAFG), used in assessing potential vapor intrusion (VI) impacts to indoor air, given measured groundwater concentrations of volatile chemicals of concern (e.g., chlorinated solvents). The GAFG can, in turn, be used for developing groundwater screening levels for VI given target indoor air quality screening levels. In this study, we examine the validity and applicability of the GAFG both for predicting indoor air impacts and for determining groundwater screening levels. This is done using both analysis of published data and screening model calculations. Among the 774 total paired groundwater‐indoor air measurements in the USEPA's VI database (which were used by that agency to generate the GAFG) we found that there are 427 pairs for which a single groundwater measurement or interpolated value was applied to multiple buildings. In one case, up to 73 buildings were associated with a single interpolated groundwater value and in another case up to 15 buildings were associated with a single groundwater measurement (i.e., that the indoor air contaminant concentrations in all of the associated buildings were influenced by the concentration determined at a single point). In more than 70% of the cases (390 of 536 paired measurements in which horizontal building‐monitoring well distance was recorded) the monitoring wells were located more than 30 m (and one up to over 200 m) from the associated buildings. In a few cases, the measurements in the database even improbably implied that soil gas contaminant concentrations increased, rather than decreased, in an upward direction from a contaminant source to a foundation slab. Such observations indicate problematic source characterization within the data set used to generate the GAFG, and some indicate the possibility of a significant influence of a preferential contaminant pathway. While the inherent value of the USEPA database itself is not being questioned here, the above facts raise the very real possibility that the recommended groundwater attenuation factors are being influenced by variables or conditions that have not thus far been fully accounted for. In addition, the predicted groundwater attenuation factors often fall far beyond the upper limits of predictions from mathematical models of VI, ranging from screening models to detailed computational fluid dynamic models. All these models are based on the same fundamental conceptual site model, involving a vadose zone vapor transport pathway starting at an underlying uniform groundwater source and leading to the foundation of a building of concern. According to the analysis presented here, we believe that for scenarios for which such a “traditional” VI pathway is appropriate, 10?4 is a more appropriately conservative generic groundwater to indoor air attenuation factor than is the EPA‐recommended 10?3. This is based both on the statistical analysis of USEPA's VI database, as well as the traditional mathematical models of VI. This result has been validated by comparison with results from some well‐documented field studies.  相似文献   

8.
The occurrence of aerobic biodegradation in the vadose zone between a subsurface source and a building foundation can all-but eliminate the risks from methane and petroleum vapor intrusion (PVI). Understanding oxygen availability and the factors that affect it (e.g., building sizes and their distribution) are therefore critical. Uncovered ground surfaces allow oxygen access to the subsurface to actively biodegrade hydrocarbons (inclusive of methane). Buildings can reduce the net flux of oxygen into the subsurface and so reduce degradation rates. Here we determine when PVI and methane risk is negligible and/or extinguished; defined by when oxygen is present across the entire sub-slab region of existing or planned slab-on-ground buildings. We consider all building slab sizes, all depths to vapor sources and the effect of spacings between buildings on the availability of oxygen in the subsurface. The latter becomes critical where buildings are in close proximity or when increased building density is planned. Conservative assumptions enable simple, rapid and confident screening should sites and building designs comply to model assumptions. We do not model the aboveground “building” processes (e.g., air exchange), and assume the slab-on-ground seals the ground surface so that biodegradation of hydrocarbons is minimized under the built structure (i.e., the assessment remains conservative). Two graphs represent the entirety of the outcomes that allow simple screening of hydrocarbon vapors based only on the depth to the source of vapors below ground, the concentration of vapors within the source, the width of the slab-on-ground building, and the gap between buildings; all independent of soil type. Rectangular, square, and circular buildings are considered. Comparison with field sites and example applications are provided, along with a simple 8-step screening guide set in the context of existing guidance on PVI assessment.  相似文献   

9.
Quantifying human cancer risk arising from exposure to contaminated groundwater is complicated by the many hydrogeological, environmental, and toxicological uncertainties involved. In this study, we used Monte Carlo simulation to estimate cancer risk associated with tetrachloroethene (PCE) dissolved in groundwater by linking three separate models for: (1) reactive contaminant transport; (2) human exposure pathways; and (3) the PCE cancer potency factor. The hydrogeologic model incorporates an analytical solution for a one-dimensional advective–dispersive–reactive transport equation to determine the PCE concentration in a water supply well located at a fixed distance from a continuous source. The pathway model incorporates PCE exposure through ingestion, inhalation, and dermal contact. The toxicological model combines epidemiological data from eight rodent bioassays of PCE exposure in the form of a composite cumulative distribution frequency curve for the human PCE cancer potency factor. We assessed the relative importance of individual model variables through their correlation with expected cancer risk calculated in an ensemble of Monte Carlo simulations with 20,000 trials. For the scenarios evaluated, three factors were most highly correlated with cancer risk: (1) the microbiological decay constant for PCE in groundwater, (2) the linear groundwater pore velocity, and (3) the cancer potency factor. We then extended our analysis beyond conventional expected value risk assessment using the partitioned multiobjective risk method (PMRM) to generate expected-value functions conditional to a 1 in 100,000 increased cancer risk threshold. This approach accounts for low probability/high impact outcomes separately from the conventional unconditional expected values. Thus, information on potential worst-case outcomes can be quantified for decision makers. Using PMRM, we evaluated the cost-benefit relationship of implementing several postulated risk management alternatives intended to mitigate the expected and conditional cancer risk. Our results emphasize the importance of hydrogeologic models in risk assessment, but also illustrate the importance of integrating environmental and toxicological uncertainty. When coupled with the PMRM, models integrating uncertainty in transport, exposure, and potency constitute an effective risk assessment tool for use within a risk-based corrective action (RBCA) framework.  相似文献   

10.
Diminishing rates of subsurface volatile contaminant removal by soil vapor extraction (SVE) oftentimes warrants an in-depth performance assessment to guide remedy decision-making processes. Such a performance assessment must include quantitative approaches to better understand the impact of remaining vadose zone contamination on soil gas and groundwater concentrations. The spreadsheet-based Soil Vapor Extraction Endstate Tool (SVEET) software functionality has recently been expanded to facilitate quantitative performance assessments. The updated version, referred to as SVEET2, includes expansion of the input parameter ranges for describing a site (site geometry, source characteristics, etc.), an expanded list of contaminants, and incorporation of elements of the Vapor Intrusion Estimation Tool for Unsaturated-zone Sources software to provide soil gas concentration estimates for use in vapor intrusion evaluation. As part of the update, SVEET2 was used to estimate the impact of a tetrachloroethene (PCE) vadose zone source on groundwater concentrations, comparing SVEET2 results to field-observed values at an undisclosed site where SVE was recently terminated. PCE concentrations from three separate monitoring wells were estimated by SVEET2 to be within the range of 6.0–6.7 μg/L, as compared to actual field concentrations that ranged from 3 to 11 μg/L PCE. These data demonstrate that SVEET2 can rapidly provide representative quantitative estimates of impacts from a vadose zone contaminant source at field sites. In the context of the SVE performance assessment, such quantitative estimates provide a basis to support remedial and/or regulatory decisions regarding the continued need for vadose zone volatile organic compound remediation or technical justification for SVE termination, which can significantly reduce the cost to complete for a site.  相似文献   

11.
12.
The influence of model dimensionality on predictions of mass recovery from dense non-aqueous phase liquid (DNAPL) source zones in nonuniform permeability fields was investigated using a modified version of the modular three-dimensional transport simulator (MT3DMS). Thirty-two initial two- (2D) and three-dimensional (3D) tetrachloroethene–DNAPL source zone architectures, taken from a recent modeling study, were used as initial conditions for this analysis. Commonly employed source zone metrics were analyzed to determine differences between 2D and 3D predictions: (i) down-gradient flux-averaged contaminant concentration, (ii) reductions in contaminant mass flux through a down-gradient boundary, (iii) source zone ganglia-to-pool (GTP) ratio, and (iv) time required to achieve a remediation objective. 3D flux-averaged contaminant concentrations were approximately 3.5 times lower than concentrations simulated in 2D. This difference was attributed to dilution of the contaminant concentrations down gradient of the source zone. Contaminant flux reduction predictions for a given mass recovery were generally 5% higher in 3D simulations than in 2D simulations. The GTP ratio declined over time as mass was recovered in both 2D and 3D simulations. Although the source longevity (i.e., time required to achieve 99.99% mass recovery) differed between individual 2D and 3D realizations, the mean source longevity for the 2D and 3D simulation ensembles was within 2%. 2D simulations tended to over-predict the time required to achieve lower mass recovery levels (e.g. 50% mass recovery) due to a smaller contaminated area exposed to uncontaminated water. These findings suggest that ensemble averages of 2D numerical simulations of DNAPL migration, entrapment, dissolution, and mass recovery in statistically homogenous, nonuniform media may provide reasonable approximations to average behavior obtained using simulations conducted in fully three-dimensional domains.  相似文献   

13.
The dilution attenuation factor (DAF) is a quantity used to relate the concentration of leachate leaving a source zone (e.g., landfill, impoundment, or contaminated soils) to its impact on down-gradient ground water quality. The DAF is of importance because it plays a key role in U.S. Environmental Protection Agency (EPA)'s methodologies for developing soil cleanup goals and for managing hazardous wastes. In this work, a simplistic graphically-based approach for determining site-specific and generic DAFs was developed. In this case the DAF is based on time-and vertically-averaged concentrations along the plume centerline, and the mathematical framework employs well-known analytical and semianalytical solutions for dissolved contaminant transport. Finite sources with a range of decay characteristics are allowed for. One unique feature of this work is that the graphical approach allows for varying levels of sitespecificity, and thus can be used when one has a little, or a lot, of site-specific information. The graphs visually indicate the sensitivity to various parameters, which is valuable information not easily gleaned from most numerical software simulators. This approach is, however, not applicable to very complex hydrogeologic settings (e.g., fractured geology), or to ground water flows that cannot be reasonably approximated as one-dimensional.  相似文献   

14.
The vapor intrusion impacts associated with the presence of chlorinated volatile organic contaminant plumes in the ground water beneath residential areas in Colorado and New York have been the subject of extensive site investigations and structure sampling efforts. Large data sets of ground water and indoor air monitoring data collected over a decade-long monitoring program at the Redfield, Colorado, site and monthly ground water and structure monitoring data collected over a 19-month period from structures in New York State are analyzed to illustrate the temporal and spatial distributions in the concentration of volatile organic compounds that one may encounter when evaluating the potential for exposures due to vapor intrusion. The analysis of these data demonstrates that although the areal extent of structures impacted by vapor intrusion mirrors the areal extent of chlorinated volatile organic compounds in the ground water, not all structures above the plume will be impacted. It also highlights the fact that measured concentrations of volatile organic compounds in the indoor air and subslab vapor can vary considerably from month to month and season to season. Sampling results from any one location at any given point in time cannot be expected to represent the range of conditions that may exist at neighboring locations or at other times. Recognition of this variability is important when designing sampling plans and risk management programs to address the vapor intrusion pathway.  相似文献   

15.
There is an identified need for fully representing groundwater–surface water transition zone (i.e., the sediment zone that connects groundwater and surface water) processes in modeling fate and transport of contaminants to assist with management of contaminated sediments. Most existing groundwater and surface water fate and transport models are not dynamically linked and do not consider transition zone processes such as bioturbation and deposition and erosion of sediments. An interface module is developed herein to holistically simulate the fate and transport by coupling two commonly used models, Environmental Fluid Dynamics Code (EFDC) and SEAWAT, to simulate surface water and groundwater hydrodynamics, while providing an enhanced representation of the processes in the transition zone. Transition zone and surface water contaminant processes were represented through an enhanced version of the EFDC model, AQFATE. AQFATE also includes SEDZLJ, a state‐of‐the‐science surface water sediment transport model. The modeling framework was tested on a published test problem and applied to evaluate field‐scale two‐ and three‐dimensional contaminant transport. The model accurately simulated concentrations of salinity from a published test case. For the field‐scale applications, the model showed excellent mass balance closure for the transition zone and provided accurate simulations of all transition zone processes represented in the modeling framework. The model predictions for the two‐dimensional field case were consistent with site‐specific observations of contaminant migration. This modeling framework represents advancement in the simulation of transition zone processes and can help inform risk assessment at sites where contaminant sources from upland areas have the potential to impact sediments and surface water.  相似文献   

16.
In this study, a methodology for clustering 18 lakes in Alberta, Canada using the data of 19 water quality parameters for a period of 11 years (1988–2002) is presented. The methods consist of (i) principal component analysis (PCA) to determine the dominant water quality parameters, (ii) cluster analysis techniques to develop the characteristics of the clusters, and (iii) pattern‐match lakes to determine the appropriate cluster for each of the lakes. The PCA revealed that three principal components (PCs) were able to explain ~88% of the variability and the dominant water quality parameters were total dissolved solids, total phosphorus, and chlorophyll‐a. We obtained five clusters for the period 1994–1997 by using the dominant parameters with water quality deteriorating as the cluster number increased from 1 to 5. Upon matching cluster patterns with the entire dataset, it was observed that some of the lakes belonged to the same cluster all the time (e.g., cluster 1 for lakes Elkwater, Gregg, and Jarvis; cluster 3 for Sturgeon; cluster 4 for Moonshine; and cluster 5 for Saskatoon), while others changed with time. This methodology could be applied in other regions of the world to identify the most suitable source waters and prioritize their management. It could be helpful to analyze the natural controlling processes, pollution types, impact of seasonal changes and overall quality of source waters. This methodology could be used for monitoring water bodies in a cost effective and efficient way by sampling only less number of dominant parameters instead of using a large set of parameters.  相似文献   

17.
《国际泥沙研究》2020,35(5):516-526
Heavy metal (HM) pollution in sediment is a serious concern particularly in developing nations, warranting an extensive survey to understand the current situation and propose possible remedial measures. This paper compiles the data of HMs cadmium (Cd), iron (Fe), cobalt (Co), manganese (Mn), arsenic (As), lead (Pb), chromium (Cr), copper (Cu), zinc (Zn) and nickel (Ni) in aquatic sediment from India from 1979 to 2017. It was found that mean values of Cu, Co, Zn, Pb, As, and Cr in Indian sediment were high in comparison to the Australian Interim Sediment Quality Guidelines, World Surface Rock Average, and the Threshold Effect Level for freshwater ecosystems. Anthropogenic activities, lithogenic factors, and sand intrusion are the main factors associated with HM pollution as observed using cluster analysis and principal component analysis. The results of contamination indices indicate that HM contamination ranged from average to high, in the sediment. The ecological risk assessment results showed that 11% HMs present very high risk. The cancer risk, due to the high contents of Cd, As, and Cr the ingestion pathway, showed high risk of cancer through food/water contaminated with sediment. At source reduction of HMs in industrial effluents by effluent treatment plants, and plantation of phytoremediating rooted macrophytes in sediment may help in HM mitigation of the sediment.  相似文献   

18.
Groundwater elevation fluctuation has been recognized as one mechanism causing temporal indoor air volatile organic chemical (VOC) impacts in vapor intrusion risk assessment guidance. For dissolved VOC sources, groundwater table fluctuation shortens/lengthens the transport pathway, and delivers dissolved contaminants to soils that are alternating between water saturated and variably saturated conditions, thereby enhancing volatilization potential. To date, this mechanism has not been assessed with field data, but enhanced VOC emission flux has been observed in lab-scale and modeling studies. This work evaluates the impact of groundwater elevation changes on VOC emission flux from a dissolved VOC plume into a house, supplemented with modeling results for cyclic groundwater elevation changes. Indoor air concentrations, air exchange rates, and depth to groundwater (DTW) were collected at the study house during an 86-d constant building underpressurization test. These data were used to calculate changes in trichloroethylene (TCE) emission flux to indoor air, during a period when DTW varied daily and seasonally from about 3.1 to 3.4 m below the building foundation (BF). Overall, TCE flux to indoor air varied by about 50% of the average, without any clear correlation to changes in DTW or its change rate. To complement the field study, TCE surface emission fluxes were simulated using a one-dimensional model (HYDRUS 1D) for conditions similar to the field site. Simulation results showed time-averaged surface TCE fluxes for cyclic water-table elevations were greater than for stationary water-table conditions at an equivalent time-averaged water-table position. The magnitudes of temporal TCE emission flux changes were generally less than 50% of the time-averaged flux, consistent with the field site observations. Simulation results also suggested that TCE emission flux changes due to groundwater fluctuation are likely to be significant at sites with shallow groundwater (e.g., < 0.5 m BF) and permeable soil types (e.g., sand).  相似文献   

19.
The stable isotopes of hydrogen and oxygen (δ2H and δ18O, respectively) have been widely used to investigate tree water source partitioning. These tracers have shed new light on patterns of tree water use in time and space. However, there are several limiting factors to this methodology (e.g., the difficult assessment of isotope fractionation in trees, and the labor-intensity associated with the collection of significant sample sizes) and the use of isotopes alone has not been enough to provide a mechanistic understanding of source water partitioning. Here, we combine isotope data in xylem and soil water with measurements of tree's physiological information including tree water deficit (TWD), fine root distribution, and soil matric potential, to investigate the mechanism driving tree water source partitioning. We used a 2 m3 lysimeter with willow trees (Salix viminalis) planted within, to conduct a high spatial–temporal resolution experiment. TWD provided an integrated response of plant water status to water supply and demand. The combined isotopic and TWD measurement showed that short-term variation (within days) in source water partitioning is determined mainly by plant hydraulic response to changes in soil matric potential. We observed changes in the relationship between soil matric potential and TWD that are matched by shifts in source water partitioning. Our results show that tree water use is a dynamic process on the time scale of days. These findings demonstrate tree's plasticity to water supply over days can be identified with high-resolution measurements of plant water status. Our results further support that root distribution alone is not an indicator of water uptake dynamics. Overall, we show that combining physiological measurements with traditional isotope tracing can reveal mechanistic insights into plant responses to changing environmental conditions.  相似文献   

20.
Thermocatalytic low temperature conversion (LTC) is a new method for the disposal of sewage sludge. Using this method, sludge is converted into a residual solid (coal) along with reaction water, oil, and non‐condensable gases. The oil can be used as an energy source and the coal as a substitute for charcoal. To this end, it is important to determine whether there are any easily available contaminants present in the coal generated by the process. Contaminants that can be strongly sorbed by sewage sludge solids are, e. g., pharmaceuticals and disinfectants. As an example the fate of the persistent and strong adsorbing disinfectant benzalkonium chloride (BAC) has been investigated within the LTC process. The sewage sludge was spiked with BAC and then subjected to the LTC process. The resulting coal was extracted and analyzed using LC‐LC/ESI‐MS/MS (ion trap). BAC could not be detected in the LTC coal, although it could be extracted from the spiked sludge before the LTC treatment. It can thus be concluded that the investigated compound is not easily available in the coal, and hence that its use does not present a risk.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号