首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
The achievement of adequate performance objectives for buildings under increasing seismic intensities is not only related to the performance of structural members but also to the behavior of nonstructural elements. The need to properly design nonstructural elements for earthquakes has been largely demonstrated in the last few years and has become an important objective within the earthquake engineering community. A crucial aspect in the proper design of nonstructural elements is the definition of the seismic demand in terms of both absolute acceleration and relative displacement floor response spectra. In the first part of this study, relative displacement and absolute acceleration floor response spectra were computed for four reinforced concrete moment-resisting archetype frames via dynamic time-history analyses and were compared with floor response spectra predicted by means of two recent simplified methodologies available in the literature. It was observed that one of the existing methodologies is generally unable to predict consistent absolute acceleration and relative displacement floor response spectra. An improved procedure is developed for estimating consistent floor response spectra for building structures subjected to low and medium-high seismic intensities. This new procedure improves the predictions of a relative displacement floor response spectrum by constraining its ordinates at long nonstructural periods to the expected peak absolute displacement of the floor. The resulting acceleration and relative displacement response spectra are then consistently related by the well-known pseudo-spectral relationship over the entire nonstructural period range. The effectiveness of the proposed methodology was appraised against floor response spectra computed from nonlinear time-history analyses.  相似文献   

2.
Response parameters used to estimate nonstructural damage differ depending on whether deformation‐sensitive or acceleration‐sensitive components are considered. In the latter case, seismic demand is usually represented through floor spectra, that is response spectra in terms of pseudo‐acceleration, which are calculated at the floor levels of the structure where the nonstructural components are attached to. Objective of this paper is to present a new spectrum‐to‐spectrum method for calculating floor acceleration spectra, which is able to explicitly account for epistemic uncertainties in the modal properties of the supporting structure. By using this method, effects on the spectra of possible variations from nominal values of the periods of vibration of the structure can be estimated. The method derives from the extension of closed‐form equations recently proposed by the authors to predict uniform hazard floor acceleration spectra. These equations are built to rigorously account for the input ground motion uncertainty, that is the record‐to‐record variability of the nonstructural response. In order to evaluate the proposed method, comparisons with exact spectra obtained from a standard probabilistic seismic demand analysis, as well as spectra calculated using the Eurocode 8 equation, are finally shown. Copyright © 2017 John Wiley & Sons, Ltd.  相似文献   

3.
Nonstructural components (NSCs) should be subjected to a careful and rational seismic design, in order to reduce the economic loss and to avoid threats to the life safety, as well as what concerns structural elements. The design of NSCs is based on the evaluation of the maximum inertia force, which is related to the floor spectral accelerations. The question arises as to whether Eurocode 8 is able to predict actual floor response spectral accelerations occurring in structures designed according to Eurocode 8. A parametric study is conducted on five RC frame structures in order to evaluate the floor response spectra. The structures, designed according to Eurocode 8, are subjected to a set of earthquakes, compatible with the design response spectrum. Time-history analyses are performed both on elastic and inelastic models of the considered structures. Eurocode formulation for the evaluation of the seismic demand on NSCs does not well fit the numerical results. Some comments on the target spectrum provided by AC 156 for the seismic qualification of NSC are also included.  相似文献   

4.
Past earthquakes have shown the importance for critical facilities to remain functional during seismic events. In the performance assessment of these facilities, it is therefore essential to accurately evaluate the seismic demand of nonstructural components. Evaluation of these components is also important when estimation of nonstructural repair costs is a concern. In this paper, the use of a multivariate demand model for nonstructural components is proposed, in which demand is expressed in terms of both interstory drifts and floor acceleration spectra. A model is built using statistics of the demand vector derived from the results of a limited number of inelastic response history analyses of a structure. The model is then used to simulate any number of additional realizations of the demand vector required for an accurate estimation of the probability of functionality loss. A new proposal for a predictive equation to generate approximate realizations of floor response spectra is presented. A reinforced concrete frame is selected as an illustrative example to show the implementation of the probabilistic seismic demand model and to evaluate the proposed predictive equation for the floor response spectra. The results of the case study are used to demonstrate the importance of accounting for the correlation among the demand parameters when realizations of the seismic demand of nonstructural components are simulated. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

5.
This paper investigates the response of nonstructural components in the presence of nonlinear behavior of the primary structure using floor response spectra method (FRS). The effect of several parameters such as initial natural frequency of the primary structure, natural frequency of the nonstructural components (subsystem), strength reduction factor and hysteretic model have been studied. A database of 164 registered ground acceleration time histories from the European Strong-Motion Database is used. Results are presented in terms of amplification factor and resonance factor. Amplification factor quantifies the effect of inelastic deformations of the primary structure on subsystem response. Resonance factor quantifies the variation of the subsystem response considering the primary structure acceleration. Obtained results differed from precedent studies, particularly for higher primary structure periods. Values of amplification factor are improved. Obtained results of resonance factor highlight an underestimation of peak values according to current design codes such as Eurocode 8. Therefore a new formulation is proposed.  相似文献   

6.
The maintenance of integrity and functionality of nonstructural components during earthquake excitations is of paramount importance since mechanical failure of those systems can have dramatic consequences in terms of property damage and life safety of the buildings' occupants. This paper explores the dynamic response of nonstructural elements attached on multistory buildings with well‐established floor diaphragm action. Depending on the type of support conditions, seismic response of nonstructural components may be controlled either by acceleration or displacement: Nonstructural components that are subjected to uniform support excitation are controlled primarily by the absolute spectral acceleration developing at their point of attachment on the supporting building. On the contrary, seismic response of multiply supported nonstructural components depends primarily on the relative displacements between successive support points that are imposed by the supporting building during lateral sway. These findings are illustrated from the analytical formulation and its solution through time history analysis of the governing dynamic equation of motion of the primary and secondary components of a system modeled using finite elements. The model encompasses the assembly of a multistory building along with a multiply supported gas pipeline network. It is shown that the dependence of the seismic response of nonstructural components may be linked to the deformed shape of the supporting building at the state of its maximum lateral roof displacement, thereby enabling the definition of design procedures for these systems. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

7.
Performance-Based Seismic Design is now widely recognized as the pre-eminent seismic design and assessment methodology for building structures. In recognition of this, seismic codes may require that buildings achieve multiple performance objectives such as withstanding moderate, yet frequently occurring earthquakes with minimal structural and non-structural damage, while withstanding severe, but rare earthquakes without collapse and loss of life. These objectives are presumed to be satisfied by some codes if the force-based design procedures are followed. This paper investigates the efficacy of the Eurocode 8 force-based design provisions with respect to RC frame building design and expected seismic performance. Four, eight, and 16-storey moment frame buildings were designed and analyzed using the code modal response spectrum analysis provisions. Non-linear time-history analyses were subsequently performed to determine the simulated seismic response of the structures and to validate the Eurocode 8 force-based designs. The results indicate the design of flexural members in medium-to-long period structures is not significantly influenced by the choice of effective member stiffness; however, calculated interstorey drift demands are significantly affected. This finding was primarily attributed to the code’s enforcement of a minimum spectral ordinate on the design spectrum. Furthermore, design storey forces and interstorey drift demand estimates (and therefore damage), obtained by application of the code force-based design procedure varied substantially from those found through non-linear time-history analysis. Overall, the results suggest that though the Eurocode 8 may yield life-safe designs, the seismic performance of frame buildings of the same type and ductility class can be highly non-uniform.  相似文献   

8.
Strength-reduction factors that reduce ordinates of floor spectra acceleration due to nonlinearity in the secondary system are investigated. In exchange for permitting some inelastic deformation to occur in the secondary system or its supports, these strength reduction factors allow to design the nonstructural elements or their supports for lateral forces that are smaller than those that would be required to maintain them elastically during earthquakes. This paper presents the results of a statistical analysis on component strength-reduction factors that were computed considering floor motions recorded on instrumented buildings in California during various earthquakes. The effect of yielding in the component or its anchorage/bracing in offering protection against excessive component acceleration demands is investigated. It is shown that strength-reduction factors computed from floor motions are significantly different from those computed from ground motions recorded on rock or on firm soils. In particular, they exhibit much larger reductions for periods tuned or nearly tuned to the dominant modal periods of the building response. This is due to the large differences in frequency content of ground motions and floor motions, with the former typically characterized by wide-band spectra whereas the latter are characterized by narrow-band spectra near periods of dominant modes in the response of the building. Finally, the study provides approximate equations to estimate component strength-reduction factors computed through nonlinear regression analyses.  相似文献   

9.
Nonstructural components(NSCs)are parts,elements,and subsystems that are not part of the primary loadbearing system of building structures but are subject to seismic loading.Damage to NSCs may disrupt the functionality of buildings and result in significant economic losses,injuries,and casualties.In past decades,extensive studies have been conducted on the seismic performance and seismic design methods of NSCs.As the input for the seismic design of NSCs,floor response spectra(FRS)have attracted the attention of researchers worldwide.This paper presents a state-of-the-art review of FRS.Different methods for generating FRS are summarized and compared with those in current seismic design codes.A detailed review of the parameters influencing the FRS is presented.These parameters include the characteristics of ground motion excitation,supporting building and NSCs.The floor acceleration response and the FRS obtained from experimental studies and field observations during earthquakes are also discussed.Three RC frames are used in a case study to compare the peak floor acceleration(PFA)and FRS calculated from time history analyses(THA)with that generated using current seismic design codes and different methods in the literature.Major knowledge gaps are identified,including uncertainties associated with developing FRS,FRS generation methods for different types of buildings,the need for comprehensive studies on absolute acceleration,relative velocity,and relative displacement FRS,and the calibration of FRS by field observations during earthquakes.  相似文献   

10.
This paper describes static and dynamic procedures to calculate seismic demand specified by the current seismic design code for buildings in Taiwan,which was issued in 2005.For design levels with a return period of475 years,the design spectral response acceleration can be developed for general sites,near-fault sites and Taipei Basin.In addition,in order to prevent building collapse during extremely large earthquakes and yielding of structural components and elements during frequent small earthquakes,the ...  相似文献   

11.
The period of vibration is a fundamental parameter in the force‐based design of structures as this parameter defines the spectral acceleration and thus the base shear force to which the building should be designed. This paper takes a critical look at the way in which seismic design codes around the world have allowed the designer to estimate the period of vibration for use in both linear static and dynamic analysis. Based on this review, some preliminary suggestions are made for updating the clauses related to the estimation of the periods of vibration in Eurocode 8. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

12.
A representative attenuation relationship is one of the key components required in seismic hazard assessment of a region of interest. Attenuation relationships for peak ground acceleration, peak ground velocity and response spectral accelerations for Sumatran megathrust earthquakes, covering Mw up to 9.0, are derived based on synthetic seismograms obtained from a finite‐fault kinematic model. The relationships derived are for very hard rock site condition and for a long‐distance range between 200 and 1500 km. They are then validated with recorded data from giant earthquakes on the Sumatran megathrust occurring since year 2000. A close examination of the recorded data also shows that spectral shapes predicted by most of the existing attenuation relationships and that specified in the IBC code are not particularly suitable for sites where potential seismic hazard is dominated by large‐magnitude, distant, earthquakes. Ground motions at a remote site are typically signified by the dominance of long‐period components with periods longer than 1 s, whereas the predominant periods from most of the existing attenuation relationships and the IBC code are shorter than 0.6 s. The shifting of response spectrum towards longer period range for distant earthquakes should be carefully taken into account in the formulation of future seismic codes for Southeast Asia, where many metropolises are located far from active seismic sources. The attenuation relationship derived in the present study can properly reproduce the spectral shape from distant subduction earthquakes, and could hopefully give insights into the formulation of future seismic codes. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

13.
A statistical analysis of the peak acceleration demands for nonstructural components (NSCs) supported on a variety of stiff and flexible inelastic regular moment‐resisting frame structures with periods from 0.3 to 3.0 s exposed to 40 far‐field ground motions is presented. Peak component acceleration (PCA) demands were quantified based on the floor response spectrum (FRS) method without considering dynamic interaction effects. This study evaluated the main factors that influence the amplification or decrease of FRS values caused by inelasticity in the primary structure in three distinct spectral regions namely long‐period, fundamental‐period, and short‐period region. The amplification or decrease of peak elastic acceleration demands depends on the location of the NSC in the supporting structure, periods of the component and building, damping ratio of the component, and level of inelasticity of the supporting structure. While FRS values at the initial modal periods of the supporting structure are reduced due to inelastic action in the primary structure, the region between the modal periods experiences an increase in PCA demands. A parameter denoted as acceleration response modification factor (Racc) was proposed to quantify this reduction/increase in PCA demands. Copyright © 2007 John Wiley & Sons, Ltd.  相似文献   

14.
A suite of reinforced‐concrete frame buildings located on hill sides, with 2 different structural configurations, viz step‐back and split‐foundation, are analyzed to study their floor response. Both step‐back and split‐foundation structural configurations lead to torsional effects in the direction across the slope due to the presence of shorter columns on the uphill side. Peak floor acceleration and floor response spectra are obtained at each storey's center of rigidity and at both its stiff and flexible edges. As reported in previous studies as well, it is observed that the floor response spectra are better correlated with the ground response spectrum. Therefore, the floor spectral amplification functions are obtained as the ratio of spectral ordinates at different floor levels to the one at the ground level. Peaks are observed in the spectral amplification functions corresponding to the first 2 modes in the upper portion of the hill‐side buildings, whereas a single peak corresponding to a specific kth mode of vibration is observed on the floors below the uppermost foundation level. Based on the numerical study for the step‐back and split‐foundation hill‐side buildings, simple floor spectral amplification functions are proposed and validated. The proposed spectral amplification functions take into account both the buildings' plan and elevation irregularities and can be used for seismic design of acceleration‐sensitive nonstructural components, given that the supporting structure's dynamic characteristics, torsional rotation, ground‐motion response spectrum, and location of the nonstructural components within the supporting structure are known, because current code models are actually not applicable to hill‐side buildings.  相似文献   

15.
考虑楼板变形带转换层高层建筑结构简化计算   总被引:1,自引:0,他引:1  
带转换层高层建筑属于复杂结构体系,其楼板变形问题较为突出,考虑楼板变形对带转换层高层建筑结构进行的地震反应简化计算研究非常必要.首先将带转换层的整体结构以转换层为界划分为若干个子结构部分;其次,对每个子结构内部的各类型竖向构件以轴线为单位运用超单元法进行简化等效,对其楼板和转换梁等水平构件则视为深梁,对所有构件考虑其类型、剪切变形、弯曲变形和轴向变形等因素的影响建立其单元刚度矩阵;最后,通过坐标变换和自由度缩减形成各子结构整体刚度矩阵,根据依次放松约束节点的计算思路完成整体结构的动力计算.算例结果表明,该简化计算法计算量小精度较高.  相似文献   

16.
With the development and implementation of performance-based earthquake engineering,harmonization of performance levels between structural and nonstructural components becomes vital. Even if the structural components of a building achieve a continuous or immediate occupancy performance level after a seismic event,failure of architectural,mechanical or electrical components can lower the performance level of the entire building system. This reduction in performance caused by the vulnerability of nonstructural components has been observed during recent earthquakes worldwide. Moreover,nonstructural damage has limited the functionality of critical facilities,such as hospitals,following major seismic events. The investment in nonstructural components and building contents is far greater than that of structural components and framing. Therefore,it is not surprising that in many past earthquakes,losses from damage to nonstructural components have exceeded losses from structural damage. Furthermore,the failure of nonstructural components can become a safety hazard or can hamper the safe movement of occupants evacuating buildings,or of rescue workers entering buildings. In comparison to structural components and systems,there is relatively limited information on the seismic design of nonstructural components. Basic research work in this area has been sparse,and the available codes and guidelines are usually,for the most part,based on past experiences,engineering judgment and intuition,rather than on objective experimental and analytical results. Often,design engineers are forced to start almost from square one after each earthquake event: to observe what went wrong and to try to prevent repetitions. This is a consequence of the empirical nature of current seismic regulations and guidelines for nonstructural components. This review paper summarizes current knowledge on the seismic design and analysis of nonstructural building components,identifying major knowledge gaps that will need to be filled by future research. Furthermore,considering recent trends in earthquake engineering,the paper explores how performance-based seismic design might be conceived for nonstructural components,drawing on recent developments made in the field of seismic design and hinting at the specific considerations required for nonstructural components.  相似文献   

17.
二次结构常常在大震甚至中小地震中发生损坏或中断工作,急需寻找安全有效的设计方法。对一幢典型结构,考虑不同场地条件、主体结构隔震以及二次结构不同阻尼比的影响,计算各层的楼面绝对加速度与相对位移反应谱。分析表明,主体结构隔震或同时增大二次结构阻尼是取得二次结构较好减振效果的有效途径,主体结构的隔震阻尼不宜太大,主体结构隔震后二次结构对所在楼层位置的敏感性大大降低。  相似文献   

18.
With the development and implementation of performance-based earthquake engineering, harmonization of performance levels between structural and nonstructural components becomes vital. Even if the structural components of a building achieve a continuous or immediate occupancy performance level after a seismic event, failure of architectural, mechanical or electrical components can lower the performance level of the entire building system. This reduction in performance caused by the vulnerability of nonstructural components has been observed during recent earthquakes worldwide. Moreover, nonstructural damage has limited the functionality of critical facilities, such as hospitals, following major seismic events. The investment in nonstructural components and building contents is far greater than that of structural components and framing. Therefore, it is not surprising that in many past earthquakes, losses from damage to nonstructural components have exceeded losses from structural damage. Furthermore, the failure of nonstructural components can become a safety hazard or can hamper the safe movement of occupants evacuating buildings, or of rescue workers entering buildings. In comparison to structural components and systems, there is relatively limited information on the seismic design of nonstructural components. Basic research work in this area has been sparse, and the available codes and guidelines are usually, for the most part, based on past experiences, engineering judgment and intuition, rather than on objective experimental and analytical results. Often, design engineers are forced to start almost from square one after each earthquake event: to observe what went wrong and to try to prevent repetitions. This is a consequence of the empirical nature of current seismic regulations and guidelines for nonstructural components. This review paper summarizes current knowledge on the seismic design and analysis of nonstructural building components, identifying major knowledge gaps that will need to be filled by future research. Furthermore, considering recent trends in earthquake engineering, the paper explores how performance-based seismic design might be conceived for nonstructural components, drawing on recent developments made in the field of seismic design and hinting at the specific considerations required for nonstructural components.  相似文献   

19.
我国在非结构构件抗震性能方面的实验研究尚处于起步阶段。首先介绍了美国纽约州立大学布法罗分校非结构构件模拟器的加载制度(UB-NCS加载制度)。在此基础上,为了考虑结构特性对非结构构件地震反应特性的影响,建议以结构在大量地震动作用下的非线性时程反应为依据,确定楼面峰值加速度和最大层间位移沿结构高度方向的分布函数。将其用于UB-NCS加载制度,可得到针对某一具体结构中位于某一楼层的非结构构件的位移时程加载曲线。该方法在对非结构构件进行检测加载时,能够考虑其所在结构的非线性地震反应特性,可用于研究不同的结构体系或地震损伤控制技术在减轻非结构震害方面的效果。  相似文献   

20.
现阶段基于性能的抗震设计思想不仅关注结构自身体系的安全,而且保护非结构构件在地震作用下使用功能完好。对于工业建筑结构,生产设备在地震作用下受损会影响震后功能恢复。加速度敏感型非结构构件一般采用楼层加速度指标来量化其地震损伤程度。以三个不同高度的钢抗弯框架规则结构体系为研究对象,采用与竖向目标谱匹配的近断层非脉冲和脉冲地震动作为竖向地震输入,考察不同质量不规则程度下,楼层竖向绝对加速度随建筑高度的变化趋势,并从反应谱角度分析不规则质量分布对楼层加速度响应的影响。结果表明:4层结构在非脉冲地震作用下楼层顶层处竖向绝对加速度是地面竖向峰值加速度的5倍之多,某一层质量的突变会引起该层及其他楼层竖向绝对加速度的明显变化。另外,对现有计算楼层竖向加速度响应的经验公式进行验证,发现美国ASCE 7-16规范的估计结果偏于保守。  相似文献   