首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
This article documents the analytical study and feasibility of placing a tuned mass damper in the form of a limber rooftop moment frame atop relatively stiff structures to reduce seismic acceleration response. Six existing structures were analytically studied using a suite of time history and response spectra records. The analyses indicate that adding mass in conjunction with a limber frame results in an increase in the fundamental period of each structure. The fundamental period increase generally results in a decrease in seismic acceleration response for the same time history and response spectra records. Owing to the limber nature of the rooftop frames, non‐linear analysis methods were required to evaluate the stability of the rooftop tuned mass damper frame. The results indicate the addition of a rooftop tuned mass damper frame reduces the seismic acceleration response for most cases although acceleration response can increase if the rooftop frame is not tuned to accommodate the specific structure's dynamic behaviour and localized soil conditions. Appropriate design of the rooftop tuned mass damper frame can result in decreased seismic acceleration response. This translates to safer structures if used as a retrofit measure or a more economical design if used for new construction. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

2.
提出一种组合型减震结构,由钢框架、节点阻尼器和原结构连接组成,外附钢框架将节点阻尼器连接在原混凝土框架结构上形成的增设节点阻尼器的外附钢框架结构,节点阻尼器的剪切滞回变形可以减小结构自身需要消耗的能量,从而提高原结构抗震性能。对原混凝土结构和增设节点阻尼器的组合型结构进行了的振动台试验。通过分析结构在不同地震波激励下的加速度和位移响应,得出楼层加速度和层位移的减震效果。研究结果表明:该结构体系在小震作用下通过提高结构刚度来增强其抗震性能;在大震作用下则可借助节点阻尼器的变形耗能来提升结构耗能能力,结构加速度减震系数达到53%,层间位移减震系数高达72%,验证了增设节点阻尼器的外附钢框架结构的减震效果。  相似文献   

3.
基础隔震技术广泛应用于建筑结构以减轻结构的地震响应.值得注意的是,在隔震体系中减小主结构的加速度响应是以牺牲隔震器变形为代价的.调谐惯容系统(TID)和隔震器组成的混合隔震体系可减小隔震层的位移响应.与传统调谐质量阻尼器(TMD)结构类似,TID 由惯容、调谐弹簧和阻尼元件组成.因此,可直接利用 TMD减震系统的设计公式来确定 TID 的最优参数.首先基于单自由度体系(SDOF)附加 TID的运动方程,推导分析两种 TID和 TMD设计公式,对两者设计公式的前提条件和适用性进行深入的探讨.其后,借助基础隔震体系的benchmark模型来检验设计 TID的可行性和有效性.数值模拟结果表明,在不增加主结构绝对加速度响应的情况下, TID能够显著减小基础隔震结构的位移响应和基底剪力.  相似文献   

4.
The results of experimental tests carried out on reinforced concrete (RC) full‐scale 2‐storey 2‐bays framed buildings are presented. The unretrofitted frame was designed for gravity loads only and without seismic details; such frame was assumed as a benchmark system in this study. A similar RC frame was retrofitted with buckling‐restrained braces (BRBs). The earthquake structural performance of both prototypes was investigated experimentally using displacement‐controlled pushover static and cyclic lateral loads. Modal response properties of the prototypes were also determined before and after the occurrence of structural damage. The results of the dynamic response analyses were utilized to assess the existing design rules for the estimation of the elastic and inelastic period of vibrations. Similarly, the values of equivalent damping were compared with code‐base relationships. It was found that the existing formulations need major revisions when they are used to predict the structural response of as‐built RC framed buildings. The equivalent damping ratio ξeq was augmented by more than 50% when the BRBs was employed as bracing system. For the retrofitted frame, the overstrength Ω and the ductility µ are 1.6 and 4.1, respectively; the estimated R‐factor is 6.5. The use of BRBs is thus a viable means to enhance efficiently the lateral stiffness and strength, the energy absorption and dissipation capacity of the existing RC substandard frame buildings. The foundation systems and the existing members of the superstructure are generally not overstressed as the seismic demand imposed on them can be controlled by the axial stiffness and the yielding force of the BRBs. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

5.
This paper proposes bi‐directional coupled tuned mass dampers (BiCTMDs) for the seismic response control of two‐way asymmetric‐plan buildings subjected to bi‐directional ground motions. The proposed BiCTMD was developed from the three‐degree‐of‐freedom modal system, which represents the vibration mode of a two‐way asymmetric‐plan building. The performance of the proposed BiCTMD for the seismic response control of elastic two‐way asymmetric‐plan buildings was verified by investigating the reductions of the amplitudes of the associated frequency response functions. In addition, the investigation showed that the proposed BiCTMD is effective in reducing the seismic damage of inelastic asymmetric‐plan buildings. Therefore, the BiCTMD is an effective approach for the seismic response control of both elastic and inelastic two‐way asymmetric‐plan buildings. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

6.
结构附加粘滞阻尼器的抗震设计   总被引:2,自引:0,他引:2  
本文结合抗震设计规范反应谱,给出了一个附加非线性流体粘滞阻尼器结构的抗震设计方法。研究了非线性阻尼器的力学特性,引入了非线性流体阻尼器的等效线性阻尼比,给出了计算最大加速度时刻附加非线性流体阻尼器结构反应的荷载组合系数,提出了按阻尼力的水平力分量与楼层剪力成正比的原则分配阻尼器阻尼系数的方法。同时给出了基于抗震规范设计反应谱附加非线性阻尼器结构的设计流程,通过一个算例说明了使用该方法设计附加非线性粘滞阻尼器结构的全过程。算例分析表明,这种设计方法适合于手算,便于设计人员掌握,在初步设计阶段可以快速、有效地设计满足给定性能水平的附加非线性流体阻尼器体系。  相似文献   

7.
Scientific research proposing any type of device/technique for seismic protection of buildings is generally based on numerical models that adopt simplifications to make possible extensive analyses. This means that important details of the inelastic response could be neglected. Following this consideration, regardless of the device/technique invented, before it could be put into practice, an experimental verification of the actual structural performance should be conducted by full-scale tests at building level. This issue is investigated in the paper considering seismic retrofit of reinforced concrete (RC) framed structures by buckling-restrained braces (BRBs) as technique to be validated, while hybrid test is selected as tool for experimental validation at building level. The analysed seismic upgrading technique consists in the insertion of BRBs into the RC frame. The upgrading intervention is designed by a method developed in previous studies. This technique responds to an important need of the society. Indeed, existing RC frames showed high vulnerability in occurrence of past earthquakes when they were not originally conceived to sustain horizontal forces. The hybrid test is selected among the available experimental techniques because it allows the experimentation on full-scale specimens with reasonable cost. In this study, a substructure hybrid test was conducted and the results are here presented to (a) evaluate the effectiveness of the design method of BRBs for seismic upgrading, (b) investigate the integration of BRBs in existing RC frame, and (c) show the potentiality of the substructure hybrid test for the experimental verification of innovative techniques for seismic protection of buildings.  相似文献   

8.
朱晓莹  吴浩  周颖 《地震工程学报》2022,44(6):1317-1324
相对传统结构,自复位墙结构在地震作用下具有更大的变形能力且几乎无残余位移,但其耗能能力较弱,需采用附加阻尼来增加整体耗能.目前,金属阻尼器已广泛用于自复位墙结构,其可显著减小结构大震下的地震响应,但小震下的位移和加速度减震效果不佳.因此,将小变形下即可耗能的黏弹性阻尼器应用于自复位墙结构中.设计一幢10层自复位墙结构,分别采用黏弹性阻尼器和 U 型金属阻尼器作为附加耗能构件,通过弹塑性时程分析对比采用两种耗能机制的结构地震响应.结果表明,黏弹性阻尼器可显著减小自复位墙结构在小震下的位移和加速度响应;U 型金属阻尼器在中震下开始耗能,在大震和巨震下,其减震效果会超越黏弹性阻尼器.因此,为进一步优化自复位墙结构在不同水准地震作用下的抗震性能,建议结合阻尼器的特点进行合理设计.  相似文献   

9.
地震作用下钢框架高层结构的抗震性能研究   总被引:1,自引:0,他引:1       下载免费PDF全文
邢磊  贾宝新  邢锐 《地震工程学报》2019,41(6):1482-1487
钢框架高层建筑结构是当前高层建筑设计中使用最为广泛的技术,为提升其抗震性能,本文研究将调谐质量阻尼器安装在钢框架高层建筑结构顶部,考虑到建筑空间需求、防止集中荷载和提升控制效果等因素,在相同楼层或同顶部接近楼层中设置数个较小的、频率一致的子控制装置,通过设置调谐质量阻尼器受控结构等效阻尼比求极值的方法,获取最优刚度与最优阻尼系数;将获取的结果在有限元软件中进行模态分析获取模态质量,实现钢框架高层建筑结构扭转振动的减振控制。实验结果表明,地震荷载下,该方法使得建筑结构顶层角位移峰值和角加速度峰值分别降低50%和30%左右,建筑结构响应下降19%~26%,提高了高层建筑结构的稳定性。  相似文献   

10.
将参数化建模的方法引入减震结构的分析与设计中,通过预设目标和迭代优化计算,以天水市某高层住宅消能减震结构为例,寻找最优的阻尼器布置方案。为评估和验证该消能减震结构的抗震性能,分别采用Perform 3D和ETABS等软件分析结构在多遇和罕遇地震作用下的结构响应,分析结果表明:小震作用下,消能减震结构的楼层位移、层间位移角、楼层弯矩及楼层剪力均减小6.5%以上,达到了设计要求;大震作用下,结构框架柱、框架梁、剪力墙和阻尼器能够满足既定的性能要求,层间位移角满足规范限值,能够达到“大震不倒”的设计目标,研究结果为实际工程预设减震目标和阻尼器优化布置提供参考。  相似文献   

11.
This paper presents the results of 12 full‐scale tests on buckling‐restrained brace (BRB) specimens. A simple‐to‐fabricate all‐steel encasing joined by high‐strength bolts was used as the buckling‐restrainer mechanism. Steel BRBs offer significant energy dissipation capability through nondeteriorating inelastic response of an internal ductile core. However, seismic performance of BRBs is characterized by interaction between several factors. In this experimental study, the effects of core‐restrainer interfacial condition, gap size, loading history, bolt spacing, and restraining capacity are evaluated. A simple hinge detail is introduced at the brace ends to reduce the flexural demand on the framing components. Tested specimens with bare steel contact surfaces exhibited satisfactory performance under the American Institute of Steel Construction qualification test protocol. The BRBs with friction‐control self‐adhesive polymer liners and a graphite‐based dry lubricant displayed larger cumulative inelastic ductility under large‐amplitude cyclic loading, exceeding current code minimum requirements. The BRB system is also examined under repeated fast‐rate seismic deformation history. This system showed significant ductility capacity and remarkable endurance under dynamic loading. Furthermore, performance is qualified under long‐duration loading history from subduction zone's megathrust type of earthquake. Predictable and stable performance of the proposed hinge detail was confirmed by the test results. Internally imposed normal thrust on the restrainer is measured using series of instrumented bolts. Weak‐ and strong‐axis buckling responses of the core are examined. Higher post‐yield stiffness was achieved when the latter governed, which could be advantageous to the overall seismic response of braced frames incorporating BRBs.  相似文献   

12.
付光磊  孙锐  宋妍 《中国地震》2020,36(1):162-172
提高学校公共建筑在地震作用下的抗震能力是自汶川地震后一直备受关注的研究课题。高烈度地区对地震设防烈度要求较高,该类建筑的结构抗震设计难度较大。通过对常规框架结构方案及增设金属阻尼器的消能减震方案进行对比分析,发现在地震作用下阻尼器发生剪切变形,小震工况即屈服耗能,能够提供1%的附加阻尼比。相比于传统框架结构,消能减震方案能够有效减小结构构件的尺寸,进而满足学校建筑对于净高的要求。在罕遇地震作用下,该结构体系满足"强柱弱梁"的设计准则,结构位移角满足规范要求,抗震性能较纯框架结构好。研究结论可为金属阻尼器的设计和进一步研究提供参考。  相似文献   

13.
This paper proposes a single‐sided vibro‐impact track nonlinear energy sink (SSVI track NES) as an effective way to mitigate the effects of impulsive and seismic excitation on building structures. The SSVI track NES is a passive energy dissipation device, which consists of a mass moving along a track, the shape of which provides a nonlinear restoring force to the mass. Previous studies have analyzed the track NES, which considers the track shape to be smooth and symmetric. By introducing a discontinuity into the shape of the track (e.g., through impact), energy in the primary structure can be scattered to higher frequency responses where it can be dissipated at a faster rate. First, the SSVI track NES is analytically investigated and numerically optimized base on a two degree‐of‐freedom primary structure. The results of numerical simulations show that the SSVI track NES can be more efficient than both the track NES and tuned mass damper in reducing the response of the primary structure. Based on the analytical studies, the SSVI track NES is experimentally realized and investigated when subjected to both impulse‐like and seismic excitations, confirming the numerical predictions and validating the analytical model of the device. Finally, the robustness of the SSVI track NES is investigated numerically. The results of this investigation indicate that the SSVI track NES remains effective over a broad range of input excitation energy levels, as well as during significant changes in the stiffness of the primary structure. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

14.
The tuned mass damper inerter (TMDI) couples the classical tuned mass damper (TMD) with an inerter, a mechanical device whose generated force is proportional to the relative acceleration between its terminals, thus providing beneficial mass‐amplification effects. This paper deals with a dynamic layout in which the TMDI is installed below the isolation floor of base‐isolated structures in order to enhance the earthquake resilience and reduce the displacement demand. Unlike most of the literature studies that assumed a linearized behavior of the isolators, the aim of this paper is to investigate the effectiveness of the TMDI while accounting for the nonlinearity of the isolators. Two nonlinear constitutive behaviors are considered, a Coulomb friction model and a Bouc‐Wen hysteretic model, representative of friction pendulum and of lead‐rubber‐bearing isolators, respectively. Optimal design is based on the stochastic dynamic analysis of the system, by modeling the base acceleration as a Kanai‐Tajimi filtered stationary random process and resorting to the stochastic linearization technique to handle the nonlinear terms. Different tuning criteria based on displacement, acceleration, and energy‐based performance indices are defined, and their implications in a design process are discussed. It is proven that the improved robustness of the TMDI reduces its performance sensitivity to the tuning frequency and to the earthquake frequency content, which are well‐known shortcomings of TMD‐like systems. This important feature makes the TMDI particularly suitable for nonlinear base‐isolated structures that are affected by unavoidable uncertainties in the isolators' properties and that may experience changes of isolators effective stiffness depending on the excitation level.  相似文献   

15.
用主动调频质量阻尼器控制高层建筑的风致振动   总被引:5,自引:1,他引:4  
本文提出了用于高层建筑风振动控制的主动调频质量阻尼器(ATMD)设计的一种简单方法。从TMD的工作原理出发,在物理意义上显式定义主动控制力的构成,基于结构的SDOF模型和广义脉动风力的高斯白噪声假定,在频域的以最小化结构顶层位移方差为设计目标,对控制力增益进行参数优化,得出控制力增益的封闭解,文中提出了以维持TMD行程恒定为目标进行参数选择的设计方案,一超高层建筑作为算例给出,数值分析表明,所设计  相似文献   

16.
斜拉桥纵向设置粘滞阻尼器参数分析   总被引:4,自引:2,他引:4  
采用Maxwell阻尼模型模拟了粘滞阻尼器的滞回耗能特性。通过对设置粘滞阻尼器斜拉桥纵向非线性地震反应的分析,讨论了粘滞阻尼器各参数对结构地震响应的影响,并通过计算证实了粘滞阻尼器具有良好的消能减振效果。  相似文献   

17.
By advancing the technologies regarding seismic control of structures and development of earthquake resistance systems in the past decades application of different types of earthquake energy dissipation system has incredibly increased. Viscous damper device as a famous and the simplest earthquake energy dissipation system is implemented in many new structures and numerous number of researches have been done on the performance of viscous dampers in structures subjected to earthquake. The experience of recent severe earthquakes indicates that sometimes the earthquake energy dissipation devices are damaged during earthquakes and there is no function for structural control system. So, damage of earthquake energy dissipation systems such as viscous damper device must be considered during design of earthquake resistance structures.This paper demonstrates the development of three-dimensional elasto-plastic viscous damper element consisting of elastic damper in the middle part and two plastic hinges at both ends of the element which are compatible with the constitutive model to reinforce concrete structures and are capable to detect failure and damage in viscous damper device connections during earthquake excitation. The finite element model consists of reinforced concrete frame element and viscous damper element is developed and special finite element algorithm using Newmark׳s direct step-by-step integration is developed for inelastic dynamic analysis of structure with supplementary elasto-plastic viscous damper element. So based on all the developed components an especial finite computer program has been codified for “Nonlinear Analysis of Reinforced Concrete Buildings with Earthquake Energy Dissipation System”. The evaluation of seismic response of structure and damage detection in structural members and damper device was carried out by 3D modeling, of 3 story reinforced concrete frame building under earthquake multi-support excitation.  相似文献   

18.
Buckling restrained braces (BRBs) are very effective in dissipating energy through stable tension–compression hysteretic cycles and have been successfully experimented in the seismic protection of buildings. Their behavior has been studied extensively in the last decades and today the level of performance guaranteed by these devices and the technological constrains that have to be fulfilled to optimize their behavior are well known. Furthermore, several companies in the world have developed their own BRBs and are now producing them. In spite of this, many seismic codes (for instance, the EuroCode 8) do not stipulate provisions for the design and construction of earthquake‐resistant structures equipped with BRBs. This discourages the structural engineering community from using these devices and seriously limits their use in structural applications. In this paper a procedure for the seismic design of steel frames equipped with BRBs is proposed. Furthermore, the paper presents a numerical investigation aimed at validating this design procedure and proposing the value of the behavior factor q that should be used for this structural type. To this end, a set of frames with BRBs is first designed by means of several values of q. Then, the obtained frames are subjected to a set of accelerograms compatible with the elastic response spectrum considered in design. The seismic response of the frames is determined by nonlinear dynamic analysis and represented in terms of the ductility demand of BRBs and the internal force demand of nondissipative members (beams and columns). Finally, the largest value of q that leads to acceptable seismic performance of the analyzed frames is assumed as adequate. The value of q is given in the paper as a continuous function of the assumed ductility capacity of the BRBs. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

19.
This paper assesses the seismic performance of typical reinforced concrete (RC) existing framed structures designed for gravity loads only. The sample two-storey structural system exhibits high vulnerability, i.e. low lateral resistance and limited translation ductility; hence an effective strategy scheme for seismic retrofitting was deemed necessary. Such a scheme comprises buckling restrained braces (BRBs) placed along the perimeter frames of the multi-storey building. The adopted design approach assumes that the global response of the inelastic framed structure is the sum of the elastic frame (primary system) and the system comprising perimeter diagonal braces (secondary system); the latter braces absorb and dissipate a large amount of hysteretic energy under earthquake ground motions. Comprehensive nonlinear static (pushover) and dynamic (response history) analyses were carried out for both the as-built and retrofitted structures to investigate the efficiency of the adopted intervention strategy. A set of seven code-compliant natural earthquake records was selected and employed to perform inelastic response history analyses at serviceability (operational and damageability limit states, OLS and DLS) and ultimate limit states (life safety and collapse prevention limit states, LSLS and CPLS). Both global and local lateral displacements are notably reduced after the seismic retrofit of the existing system. In the as-built structure, the damage is primarily concentrated at the second floor (storey mechanism); the computed interstorey drifts are 2.43% at CPLS and 1.92% at LSLS for modal distribution of lateral forces. Conversely, for the retrofitted system, the estimated values of interstorey drifts (d/h) are halved; the maximum d/h are 0.84% at CPLS (along the Y-direction) and 0.65% at LSLS (yet along the Y-direction). The values of the global overstrength Ω vary between 2.14 and 2.54 for the retrofitted structure; similarly, the translation ductility μΔ-values range between 2.07 and 2.36. The response factor (R- or q-factor) is on average equal to 5.0. It is also found that, for the braced frame, under moderate-to-high magnitude earthquakes, the average period elongation is about 30%, while for the existing building the elongation is negligible (lower than 5%). The inelastic response of the existing structure is extremely limited. Conversely, BRBs are effective to enhance the ductility and energy dissipation of the sample as-built structural system. Extensive nonlinear dynamic analyses showed that more than 60% of input seismic energy is dissipated by the BRBs at ultimate limit states. The estimated maximum axial ductility of the braces is about 10; the latter value of translation ductility is compliant with BRBs available on the market. At DLS, the latter devices exhibit an elastic behaviour. It can thus be concluded that, under moderate and high magnitude earthquakes, the damage is concentrated in the added dampers and the response of the existing RC framed structure (bare frame) is chiefly elastic.  相似文献   

20.
The optimal design and effectiveness of three control systems, tuned viscous mass damper(TVMD), tuned inerter damper(TID) and tuned mass damper(TMD), on mitigating the seismic responses of base isolated structures, were systematically studied. First, the seismic responses of the base isolated structure with each control system under white noise excitation were obtained. Then, the structural parameter optimizations of the TVMD, TID and TMD were conducted by using three different objectives. The results show that the three control systems were all effective in minimizing the root mean square value of seismic responses, including the base shear of the BIS, the absolute acceleration of structural SDOF, and the relative displacement between the base isolation floor and the foundation. Finally, considering the superstructure as a structural MDOF, a series of time history analyses were performed to investigate the effectiveness and activation sensitivity of the three control systems under far field and near fault seismic excitations. The results show that the effectiveness of TID and TMD with optimized parameters on mitigating the seismic responses of base isolated structures increased as the mass ratio increases, and the effectiveness of TID was always better than TMD with the same mass ratio. The TVMD with a lower mass ratio was more efficient in reducing the seismic response than the TID and TMD. Furthermore, the TVMD, when compared with TMD and TID, had better activation sensitivity and a smaller stroke.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号