首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Hydrogeologic and ground water quality data obtained from a gas-driven multilevel sampler system and a polyvinyl chloride (PVC) monitoring well nest with the same aquifer communication intervals are compared. All monitoring points are in close proximity to each other. The study was conducted at an eight-acre uncontrolled hazardous waste site. The site is located in an alluvial valley composed of approximately 40 feet of alluvium overlying shale bedrock. The ground water at the site is contaminated with various organic constituents. A ground water monitoring network consisting of 26 conventional monitoring wells, nine observation well points, and six multilevel gas-driven samplers was established to characterize the hydrogeologic regime and define the vertical and horizontal extent of contamination in the vicinity of the abandoned chemical plant. As part of this study, a multilevel monitoring system was installed adjacent to a well nest. The communication zones of the multilevel samplers were placed at the same elevation as the sand packs of the well nest. The multilevel sampler system and well nest are located in a contaminated area directly downgradient of the site. A comparison of the vertical head distribution and ground water quality was performed between the well nest and the multilevel sampling system. The gas-driven multilevel sampling system consists of three gas-driven samplers that monitor separate intervals in the unconsolidated materials. The well nest, composed of two PVC monitoring wells in separate boreholes, has the same communication interval as the other two gas-driven samplers. Hydraulic head information for each multilevel sampler was obtained using capillary tubing. This was compared with heads obtained from the well nest utilizing an electric water level indicator. Chemical analyses from the PVC and multilevel sampler wells were performed and compared with one another. The analyses included organic acids, base neutrals, pesticides, PCBs, metals, volatile organics, TOX, TOC, CN, pH and specific conductance.  相似文献   

2.
Lighter-than-water Non-Aqueous Phase Liquids (LNAPLs), such as jet fuels or gasolines, are common contaminants of soils and ground water. However, the total volume and distribution of an LNAPL is difficult to accurately determine during a site investigation. LNAPL that is entrapped in the saturated zone due to fluctuating water table conditions is particularly difficult to quantify. Yet, the amount of entrapped product in the saturated zone is theoretically higher, per volume of soil, than the residual product in the unsaturated zone, and small amounts of LNAPL in the saturated zone can contaminate large volumes of ground water.
The only method currently available to quantify the amount of LNAPL is direct soil-core sampling combined with laboratory analysis of the fluid extracted from the soil cores. However, direct sampling of saturated ground water systems with conventional samplers presents a number of problems. In this study, a new sampler was developed that can be used to retrieve undisturbed soil and pore fluid samples from below the water table in cohesionless soils. The sampler uses carbon dioxide to cool the bottom of a saturated soil sample in situ to near freezing. Results of a field study where a prototype sampler was tested demonstrate the usefulness of a cryogenic sampler and show that the amount of LNAPL entrapped below the water table can be a significant part of the total LNAPL in the soil.  相似文献   

3.
The importance of obtaining depth-specific ground water samples is now well recognized among practitioners and scientists alike. Many methods and technologies are available for level discrete or depth-specific ground water sampling in consolidated aquifers. All methods have their associated advantages and drawbacks, however. One common disadvantage is that they are expensive. A large number of point discrete ground water samples were required for a UK research project aimed at quantifying natural attenuation processes in ground water contaminated by a former coal carbonization plant. Based on experience from a previous project to develop novel level accurate sampling methodologies for use in existing boreholes, the Ground Water Protection and Restoration Research Unit (GWPRRU) produced and tested a low-cost design multiport sock sampler for ground water monitoring. The sock sampler design allowed the recovery of multiple depth-specific ground water samples from depths of 150 feel (45 m) from individual boreholes in the sandstone aquifer at the field site. Because of their use of inexpensive materials, simple design, installation and use that does not require gravel packs, packers, or grouting, sock samplers were found to be the most cost effective, convenient, and reliable method of obtaining multiple depth-specific ground water samples at the project field site.  相似文献   

4.
A discrete point sampler has been developed that overcomes disadvantages inherent in several current small-volume samplers. It is designed to obtain ground water samples after a well has been purged with a pump. It consists of a sample chamber, two ports, and a stopcock for withdrawing sample aliquots. After lowering the sampler into a well, sampling is initiated by pulling on a line that sequentially removes the plugs in the lower and the upper level ports. The sample chamber fills from the bottom port and vents air from the top port. The device is suitable for sampling for volatile organic compounds in ground waters that are not subject to spontaneous bubble degassing. The upper port is sufficiently far above the lower port that none of the water that is sampled is exposed to the vented air. The sample chamber fills in such a way that the water that is taken from the chamber for analysis is not exposed to the headspace in the chamber.  相似文献   

5.
Until recently, there was little information available on the water collection capabilities of pore water samplers. This study was conducted to evaluate the performance of ceramic, fritted-glass, stainless steel, and polytetrafluoroethylene (PTFE) porous samplers in sand and silt loam soil columns over a range of soil water potentials. Soil solution intake for samplers was determined by application of constant and falling vacuums. Constant vacuum was applied for a three-day period when soils were at field moisture capacity. The PTFE samplers did not function when tested with a constant or falling vacuum. With a 50-kPa constant vacuum, the ceramic sampler collected the greatest sample volume (average 20 mL) from the sand. With a constant 25-kPa vacuum, the stainless steel sampler collected the greatest sample volume (average 81 mL) from the silt loam soil. Sampler performance with a fixed volume of vacuum was evaluated by applying 100 kPa vacuum to a 1-liter reservoir. With this falling vacuum, samplers were tested until no further solution was collected over a 10-day test period. With a falling vacuum, fritted-glass and stainless steel samplers, with relatively larger pores and greater hydraulic conductance, collected a greater volume of sample and at a faster rate than ceramic samplers in sand soil that was nearly saturated. When the volume was normalized with respect to sampler surface area, for the falling vacuum tests in silt loam soil at field moisture capacity, the volume collected by fritted glass was significantly higher than those from other samplers. In sand at field moisture capacity or silt loam at soil water tensions ≧30 kPa, ceramic samplers maintained vacuums near 70 kPa and collected more sample than the other samplers during the 10-day test period.  相似文献   

6.
The objective of most ground water quality monitoring programs is to obtain samples that are "representative" or that retain the physical and chemical properties of the ground water in an aquifer. Many factors can influence whether or not a particular sample is representative, but perhaps the most critical factor is the method or type of sampling device used to retrieve the sample.
The sampling equipment available today ranges from simple to highly sophisticated, and includes bailers, syringe devices, suction-lift pumps, gas-drive devices, bladder (Middelburg-type) pumps, gear-drive and helical rotor electric submersible pumps and gas-driven piston pumps. New devices are continually being developed for use in small-diameter wells in order to meet the needs of professionals engaged in implementing elaborate ground water monitoring programs.
In selecting a sampling device for a monitoring program, the professional must consider a number of details. Among the considerations are: the outside diameter of the device, the overall impact of the device on ground water sample integrity (including the materials from which the sampling device and associated equipment are made and the method by which the device delivers the sample), the capability of the device to purge the well of stagnant water, the rate and the ability to control the rate at which the sample is delivered, the depth limitations of the device, the ease of operating, cleaning and maintaining the device, the portability of the device and required accessory equipment, the reliability and durability of the device, and the initial and operational cost of the device and accessory equipment. Based on these considerations, each of the devices available for sampling ground water from small-diameter wells has its own unique set of advantages and disadvantages that make it suitable for sampling under specific sets of conditions. No one sampling device is applicable to all sampling situations.  相似文献   

7.
Abstract. A sampling manifold has been developed that allows the rapid collection of ground water from multilevel samplers during tracer tests. Its reliability was proven in an experiment lasting 51 days.  相似文献   

8.
Passive diffusive-adsorptive samplers are being considered for vapor intrusion (VI) pathway assessment, particularly where multi-week time-weighted average concentrations are desired. Recent studies have shown that passive samplers can produce accurate results under well-controlled steady concentration conditions, and field performance was also demonstrated at several sites. The objective of this study was to examine passive sampler performance in settings with time-varying indoor air concentrations, through a comparison of passive sampler results to concentrations determined by 24-h active sorbent tube sampling in a series of multi-week deployments. Sampling was performed in a well-instrumented residential building as well as industrial buildings, over periods of time ranging from 1 to 7 weeks. Strong linear correlations were noted between passive and active sampling concentration results for some passive samplers, with passive sampling results being similar to or lower than measured active sampling results by about 50% for those samplers in the residential study and about 25% higher in the industrial building study. Other samplers produced poor agreement. The conclusion from this study is that some passive samplers have great potential for use in multi-week indoor air quality monitoring. It was further determined that there is need for accepted procedures to validate and calibrate passive samplers for use in the field.  相似文献   

9.
Soil-gas surveying by the use of a passive sampler which allows quantitative determination of concentrations of volatile organic compounds and remote analysis of samples is described. The results of a survey using the sampler above a chloroform ground water plume are compared to ground water analysis results and to results from a previous soil-gas study above the same plume. Chloroform concentrations measured with passive samplers correlate well (r = 0.79, n = 6; r = 0.93, n = 7) with the other two techniques. The short-range variability of the technique is characterized by a coefficiet of variation of 12 percent over a 27-foot distance for nine samplers, and compares favorably with grab-sample results at the same location.  相似文献   

10.
A wide variety of sampling programmes may now be considered practical with the recent developments in data logger and water sampler technology. In ephemeral systems the water sampler remains idle for long periods between events. Two approaches are described which overcome the problems of sampling in ephemeral systems: short interval time dependent sampling (TDS) and automated flow proportional sampling (FPS). Both approaches utilize the data logger's ability to perform intermediate operations on incoming data to control the initiation of water sampling. The logger programs are described and allow many recorder/water sampler units to be controlled from one device. The relative merits of the two approaches are discussed in terms of experimental requirements and data precision.  相似文献   

11.
A standpipe system was developed for testing the reliability of ground water samplers. The unit consists of a stainless steel pipe 5 inches (13 centimeters) in diameter and 100 feet (30.5 meters) in height. It has 14 sampling ports from which control samples can be withdrawn at the same time and position as the samples are collected by a sampler lowered to that position. Test solutions were made in two mixing tanks, totaling 260 gallons (980 liters), by diluting the concentrate of five volatile chlorohydrocarbons in water at two levels of concentration: 10-to-30 and 100-to-200 parts per billion (micrograms per liter).
A gas chromatograph interfaced with a purge-and-trap system was used to perform the analyses. Comparisons of the control samples with the sampler-collected samples have indicated that the three non-pumping samplers had recoveries in the range of 92.4 to 103.5 percent and the three pumping samplers had recoveries ranging from 97.7 to 101.5 percent.  相似文献   

12.
A hydrogeologic field experiment, conducted at a research site some 125 miles (200km) from the home base, used commercially available computer controller technology for data collection and experimental control. A telephone line connected to the equipment facilitated the downloading of data, provided a means of remotely monitoring the operating performance, and made it possible to adjust the monitoring procedures.
This experiment demonstrated the benefits of a remotely controlled data acquisition system for a long-term investigation. Identification of problems and the adjustment of the sampling algorithm by telephone reduced costly travel time. The considerable amount of data collected, the data evaluation techniques, and the continuous monitoring, provided a high degree of confidence in the results.  相似文献   

13.
The accurate measurement of suspended sediment (<200 μm) in aquatic environments is essential to understand and effectively manage changes to sediment, nutrient, and contaminant concentrations on both temporal and spatial scales. Commonly used sampling techniques for suspended sediment either lack the ability to accurately measure sediment concentration (e.g., passive sediment samplers) or are too expensive to deploy in sufficient number to provide landscape‐scale information (e.g., automated discrete samplers). Here, we evaluate a time‐integrated suspended sediment sampling technique, the pumped active suspended sediment (PASS) sampler, which collects a sample that can be used for the accurate measurement of time‐weighted average (TWA) suspended sediment concentration and sediment particle size distribution. The sampler was evaluated against an established passive time‐integrated suspended sediment sampling technique (i.e., Phillips sampler) and the standard discrete sampling method (i.e., manual discrete sampling). The PASS sampler collected a sample representative of TWA suspended sediment concentration and particle size distribution of a control sediment under laboratory conditions. Field application of the PASS sampler showed that it collected a representative TWA suspended sediment concentration and particle size distribution during high flow events in an urban stream. The particle size distribution of sediment collected by the PASS and Phillips samplers were comparable and the TWA suspended sediment concentration of the samples collected using the PASS and discrete sampling techniques agreed well, differing by only 4% and 6% for two different high flow events. We should note that the current configuration of the PASS sampler does not provide a flow‐weighted measurement and, therefore, is not suitable for the determination of sediment loads. The PASS sampler is a simple, inexpensive, and robust in situ sampling technique for the accurate measurement of TWA suspended sediment concentration and particle size distribution.  相似文献   

14.
The ability of diffusion samplers constructed from regenerated cellulose dialysis membrane and low density, lay flat polyethylene tubing to collect volatile organic compounds and inorganic ions was compared in a laboratory study. Concentrations of vinyl chloride, cis -1, 2-dichloroethene, bromochloromethane, trichloroethene, bromodichloromethane, and tetrachloroethene collected by both types of diffusion samplers reached equilibrium with the concentrations of these compounds in test solution within three days. Concentrations of bromide and iron collected by the dialysis membrane diffusion samplers reached equilibrium with the concentrations of these compounds in a test solution within three to seven days. No detectable concentrations of bromide or iron were found in polyethylene diffusion samplers even after 21 days. No measurable concentrations of aluminum, arsenic, barium, cadmium, chromium, iron, mercury, manganese, nickel, and lead, or sulfide, were leached out of dialysis membrane samplers over seven days. Compared with using a gas-tight syringe to sample the diffusion sampler, clipping the bag and pouring the water sample into a sample vial resulted in only a small 6.2% average loss of volatile organic compounds. Dialysis membrane diffusion samplers offer promise for use in sampling ground water for inorganic constituents as well as volatile organic compounds.  相似文献   

15.
Passive sampling techniques facilitate the time-integrated measurement of pollutant concentrations through the use of a selective receiving phase. Accurate quantification using passive sampling devices rely on the implementation of methods that will negate the effects of environmental factors (flow, temperature, etc.) or that will allow the calculation of the chemical specific rates of uptake (R(s)) into the passive sampler employed. We have applied an in situ calibration technique based on the dissolution of gypsum to measure the average water velocity to which a sampler has been exposed. We demonstrate that the loss of gypsum from the passive flow monitor (PFM) can be applied to predict changes in R(s) dependent on flow when using the absorbent SPMD (semipermeable membrane device) and PDMS (polydimethyl siloxan) passive samplers. The application of the PFM will enhance the accuracy of measurements made when calculating and reporting environmental pollutant concentrations using a passive sampling device.  相似文献   

16.
MAROS: a decision support system for optimizing monitoring plans   总被引:3,自引:0,他引:3  
The Monitoring and Remediation Optimization System (MAROS), a decision-support software, was developed to assist in formulating cost-effective ground water long-term monitoring plans. MAROS optimizes an existing ground water monitoring program using both temporal and spatial data analyses to determine the general monitoring system category and the locations and frequency of sampling for future compliance monitoring at the site. The objective of the MAROS optimization is to minimize monitoring locations in the sampling network and reduce sampling frequency without significant loss of information, ensuring adequate future characterization of the contaminant plume. The interpretive trend analysis approach recommends the general monitoring system category for a site based on plume stability and site-specific hydrogeologic information. Plume stability is characterized using primary lines of evidence (i.e., Mann-Kendall analysis and linear regression analysis) based on concentration trends, and secondary lines of evidence based on modeling results and empirical data. The sampling optimization approach, consisting of a two-dimensional spatial sampling reduction method (Delaunay method) and a temporal sampling analysis method (Modified CES method), provides detailed sampling location and frequency results. The Delaunay method is designed to identify and eliminate redundant sampling locations without causing significant information loss in characterizing the plume. The Modified CES method determines the optimal sampling frequency for a sampling location based on the direction, magnitude, and uncertainty in its concentration trend. MAROS addresses a variety of ground water contaminants (fuels, solvents, and metals), allows import of various data formats, and is designed for continual modification of long-term monitoring plans as the plume or site conditions change over time.  相似文献   

17.
Efforts to sample representative, undisturbed distributions of uranium in ground water beneath the Fernald Environmemal Management Project (FEMP) prompted the application of a novel technique that is less invasive in the monitoring well. Recent studies (Kearl et al. 1992; Barcelona et al. 1994) indicate that representative samples can and should be collected without prior well volume exchange purging or borehole evacuation. Field experiments conducted at the FMMP demonstrate that under specific sampling conditions in a welldefined hydrogeologic system, representative ground water samples for a monitoring program can be obtained without removing the conventional three well volumes from the well. The assumption is made that indicator parameter equilibration may not be necessary to determine when to collect representative samples at the P'liMP. Preliminary results obtained from the field experiment suggest that this may be true. The technique employs low purge rates (< 1 L/min) with dedicated bladder pumps with inlets located in the screened interval of the well, while not disturbing the stagnant water column above the screened interval. If adopted, this technique, termed micro-purge low-flow sampling, will produce representative ground water samples, significantly reduce sampling costs, and minimize; waste water over the monitoring life cycle at the FEMP. This technique is well suited for sites that have been fully characterized and are undergoing long-term monitoring.  相似文献   

18.
Robowell is an automated process for monitoring selected ground water quality properties and constituents by pumping a well or multilevel sampler. Robowell was developed and tested to provide a cost-effective monitoring system that meets protocols expected for manual sampling. The process uses commercially available electronics, instrumentation, and hardware, so it can be configured to monitor ground water quality using the equipment, purge protocol, and monitoring well design most appropriate for the monitoring site and the contaminants of interest. A Robowell prototype was installed on a sewage-treatment plant infiltration bed that overlies a well-studied u neon fined sand and gravel aquifer at the Massachusetts Military Reservation, Cape Cod, Massachusetts, during a time when two distinct plumes of constituents were released. The prototype was operated from May 10 to November 13, 1996, and quality-assurance/quality-control measurements demonstrated that the data obtained by the automated method was equivalent to data obtained by manual sampling methods using the same sampling protocols. Water level, specific conductance, pH, water temperature, dissolved oxygen, and dissolved ammonium were monitored by the prototype as the wells were purged according to U.S. Geological Survey (LJSGS) ground water sampling protocols. Remote access to the data record, via phone modem communications, indicated the arrival of each plume over a few days and the subsequent geochemical reactions over the following weeks. Real-time availability of the monitoring record provided the information needed to initiate manual sampling efforts in response to changes in measured ground water quality, which proved the method and characterized the screened portion of the plume in detail through time. The methods and the case study described are presented to document the process for future use.  相似文献   

19.
Porous suction samplers have been widely used to obtain ground water samples from the vadose zone. However, previous studies identified different mechanisms that may compromise the sample's representativeness, such as volatilization and sorption. This issue is particularly important when dealing with volatile organic compounds (VOCs) as in gasoline spills. Ethanol is common in modern fuels and so may be present in ground water contamination from fuel releases. The objective of this work was to evaluate the losses of VOCs in the presence of ethanol when using porous suction samplers. Laboratory experiments were performed using a ceramic porous suction sampler to sample test solution containing benzene, toluene, xylenes, trimethylbenzenes, naphthalene, and different volumetric fractions of ethanol. Significant losses were found up to 30% for ethylbenzene. Ethanol was found to affect the accuracy of the readings by two main mechanisms: first, negatively, by increasing the headspace in the sampling tube, and second, positively, increasing partition to the aqueous phase due to the cosolvent effect and therefore decreasing the mass loss by volatilization. As a consequence, the highest losses of VOCs were found at intermediate ethanol volume fractions: 10% and 20% (v/v). The losses can be anticipated by measuring the ratio of gas to water in the sampling line and then by applying simple partition models considering cosolvency by ethanol. The importance of adequate purging when using porous suction samplers was also shown.  相似文献   

20.
Measurement and interpretation of mass fluxes in favor of concentrations is gaining more and more interest, especially within the framework of the characterization and management of large-scale volatile organic carbon (VOC) groundwater contamination (source zones and plumes). Traditional methods of estimating contaminant fluxes and discharges involve individual measurements/calculations of the Darcy water flux and the contaminant concentrations. However, taken into account the spatially and temporally varying hydrologic conditions in complex, heterogeneous aquifers, higher uncertainty arises from such indirect estimation of contaminant fluxes. Therefore, the potential use of passive sampling devices for the direct measurement of groundwater-related VOC mass fluxes is examined. A review of current passive samplers for the measurement of organic contaminants in water yielded the selection of 18 samplers that were screened for a number of criteria. These criteria are related to the possible application of the sampler for the measurement of VOC mass fluxes in groundwater. This screening study indicates that direct measurement of VOC mass fluxes in groundwater is possible with very few passive samplers. Currently, the passive flux meter (PFM) is the only passive sampler which has proven to effectively measure mass fluxes in near source groundwater. A passive sampler for mass flux measurement in plume zones with regard to long-term monitoring (several months to a year) still needs to be developed or optimized. A passive sampler for long-term monitoring of contaminant mass fluxes in groundwater would be of considerable value in the development of risk-based assessment and management of soil and groundwater pollutions.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号