首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A three‐dimensional beam–truss model (BTM) for reinforced concrete (RC) walls that explicitly models flexure–shear interaction and accurately captures diagonal shear failures was presented in the first part of this two‐paper series. This paper extends the BTM to simulate RC slabs and coupled RC walls through slabs and beams. The inclination angle of the diagonal elements for coupled RC walls is determined, accounting for the geometry of the walls and the level of coupling. Two case studies validate the model: (1) a two‐bay slab–column specimen experimentally tested using cyclic static loading and (2) a five‐story coupled T‐wall–beam–slab specimen subjected to biaxial shake table excitation. The numerically computed lateral force–lateral displacement and strain contours are compared with the experimentally measured response and observed damage. The five‐story specimen is characterized by diagonal shear failure at the bottom story of the walls, which is captured by the BTM. The BTM of the five‐story specimen is used to study the effects of coupling on shear demand for lightly reinforced RC coupled walls. The effect of mesh refinement and bar fracture of non‐ductile transverse reinforcement is studied. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

2.
This paper uses nonlinear truss models for the analysis of shear‐dominated reinforced concrete (RC) columns subjected to cyclic loading. A previously established method, aimed to the analysis of RC walls, is enhanced to allow simulations of column members. The concrete constitutive equations are modified to account for the contribution of the aggregate interlock to the shear resistance. Additionally, an equation is proposed to determine the inclination angle of the diagonal members in the truss models. The modeling approach is validated using the results of quasi‐static and dynamic tests on shear‐dominated RC columns. The combination of predictive capabilities and conceptual simplicity establishes truss‐based models as an attractive approach for the systematic analysis of shear‐dominated RC frame construction. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

3.
The experimental work and first results of a recently completed experimental research programme investigating the response of reinforced concrete (RC) walls under earthquake (EQ) loading are discussed in this paper. A brief literature review is given as a prelude to the outline of research objectives. The tests are presented in two groups according to the scale of models. For the 1:5 scale tests, a modified similitude relation for small scale reinforced concrete dynamic modelling is developed. Based on the chosen model parameters, the design of the isolated RC walls is given. The test-rig set-up and the EQ input signals suitable for testing the model on the Imperial College shake-table are also discussed. Preliminary observations regarding stiffness, strength and failure modes of the RC wall models are given. Experimental results from the shake-table are compared to tests, at the same scale, under static cyclic conditions. For the scale 1:2–5 cyclic tests a different test-rig assembly is designed. The test results are given in three pairs of flexurally similar walls followed with general observations and discussion. Finally, conclusions are drawn regarding experimental procedures and behaviour patterns of the tested models.  相似文献   

4.
5.
The steel reinforced concrete (SRC) wall consists of structural steel embedded at the boundary elements of a reinforced concrete (RC) wall. The use of SRC walls has gained popularity in the construction of high‐rise buildings because of their superior performance over conventional RC walls. This paper presents a series of quasi‐static tests used to examine the behavior of SRC walls subjected to high axial force and lateral cyclic loading. The SRC wall specimens showed increased flexural strength and deformation capacity relative to their RC wall counterpart. The flexural strength of SRC walls was found to increase with increasing area ratio of embedded structural steel, while the section type of embedded steel did not affect the wall's strength. The SRC walls under high axial force ratio had an ultimate lateral drift ratio of approximately 1.4%. In addition, a multi‐layer shell element model was developed for the SRC walls and was implemented in the OpenSees program. The numerical model was validated through comparison with the test data. The model was able to predict the lateral stiffness, strength and deformation capacities of SRC walls with a reasonable level of accuracy. Finally, a number of issues for the design of SRC walls are discussed, along with a collection and analysis of the test data, including (1) evaluation of flexural strength, (2) calculation of effective flexural stiffness, and (3) inelastic deformation capacity of SRC walls. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

6.
Widely used damage indices, such as ductility and drift ratios, do not account for the influences of the duration of strong shaking, the cumulative inelastic deformation or energy dissipation in structures. In addition, the formulation and application of most damage indices have until now been based primarily on flexural modes of failure. However, evidence from earthquakes suggests that shear failure or combined shear‐flexure behavior is responsible for a large proportion of failures. Empirical considerations have been made in this paper for evaluating structural damage of low‐rise RC walls under earthquake ground motions by means of a new energy‐based low‐cycle fatigue damage index. The proposed empirical damage index is based on the results of an experimental program that comprised six shake table tests of RC solid walls and walls with openings; results of six companion walls tested under QS‐cyclic loading were used for comparison purposes. Variables studied were the wall geometry, type of concrete, web shear steel ratio, type of web shear reinforcement, and testing method. The index correlates the stiffness degradation and the destructiveness of the earthquake in terms of the duration and intensity of the ground motions. The stiffness degradation model considers simultaneously the increment of damage associated to the low‐cycle fatigue, energy dissipation, and the cumulative cyclic parameters, such as displacement demand and hysteretic energy dissipated. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

7.
To resolve the issue regarding inaccurate prediction of the hysteretic behavior by micro-based numerical analysis for partially-restrained(PR)steel frames with solid reinforced concrete(RC)infill walls,an innovative simplified model of composite compression struts is proposed on the basis of experimental observation on the cracking distribution,load transferring mechanism,and failure modes of RC infill walls filled in PR steel frame.The proposed composite compression struts model for the solid RC infill walls is composed ofαinclined struts and main diagonal struts.Theαinclined struts are used to reflect the part of the lateral force resisted by shear connectors along the frame-wall interface,while the main diagonal struts are introduced to take into account the rest of the lateral force transferred along the diagonal direction due to the complicated interaction between the steel frame and RC infill walls.This study derives appropriate formulas for the effective widths of theαinclined strut and main diagonal strut,respectively.An example of PR steel frame with RC infill walls simulating simulated by the composite inclined compression struts model is illustrated.The maximum lateral strength and the hysteresis curve shape obtained from the proposed composite strut model are in good agreement with those from the test results,and the backbone curve of a PR steel frame with RC infill walls can be predicted precisely when the inter-story drift is within 1%.This simplified model can also predict the structural stiffness and the equivalent viscous damping ratio well when the inter-story drift ratio exceeds 0.5%.  相似文献   

8.
Reinforced concrete shear walls are used because they provide high lateral stiffness and resistance to extreme seismic loads. However, with the increase in building height, these walls have become slenderer and hence responsible of carrying larger axial and shear loads. Because 2D/3D finite element inelastic models for walls are still complex and computationally demanding, simplified but accurate and efficient fiber element models are necessary to quickly assess the expected seismic performance of these buildings. A classic fiber element model is modified herein to produce objective results under particular loading conditions of the walls, that is, high axial loads, low axial loads, and nearly constant bending moment. To make it more widely applicable, a shear model based on the modified compression field theory was added to this fiber element. Consequently, this paper shows the formulation of the proposed element and its validation with different experimental results of cyclic tests reported in the literature. It was found that in order to get objective responses in the element, the regularization techniques based on fracture energy had to be modified, and nonlinearities because of buckling and fracture of steel bars, concrete crushing, and strain penetration effects were needed to replicate the experimental cyclic behavior. Thus, even under the assumption of plane sections, which makes the element simple and computationally efficient, the proposed element was able to reproduce the experimental data, and therefore, it can be used to estimate the seismic performance of walls in reinforced concrete buildings. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

9.
This paper presents general composed analytical models to predict the behavior of reinforced concrete (RC) bridge columns. The analytical models were developed in OpenSees to represent the common hysteretic behavior of RC bridge columns. The proposed composed models can accommodate flexure failure, flexure‐shear failure, and pure shear failure, which are observed in existing RC bridge piers. The accuracy of the models was verified using data from the static cyclic‐loading experiments of 16 single columns and one multi‐column bent and dynamical experiment from two pseudo‐dynamic tests. The results showed that the analytical models could simulate the nonlinear behavior until the post‐failure behavior, including the strength degradation, the buckling of the reinforcement, and the pinching effect. Therefore, a global view of the behavior of reinforcement concrete is prescribed as simply as possible from the academic perspective, and these models are expected to provide sufficient accuracy when applied in engineering practice. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

10.
In order to further improve the seismic performance of RC shear walls, a new composite shear wall with concrete filled steel tube (CFT) columns and concealed steel trusses is proposed. This new shear wall is a double composite shear wall; the first composite being the use of three different force systems, CFT, steel truss and shear wall, and the second the use of two different materials, steel and concrete. Three 1/5 scaled experimental specimens: a traditional RC shear wall, a shear wall with CFT columns, and a shear wall with CFT columns and concealed steel trusses, were tested under cyclic loading and the seismic performance indices of the shear walls were comparatively analyzed. Based on the data from these experiments, a thorough elastic-plastic finite element analysis and parametric analysis of the new shear walls were carried out using ABAQUS software. The finite element results of deformation, stress distribution, and the evolution of cracks in each phase were compared with the experimental results and showed good agreement. A mechanical model was also established for calculating the load-carrying capacity of the new composite shear walls. The results show that this new type of shear wall has improved seismic performance over the other two types of shear walls tested.  相似文献   

11.
Experimental evidence supporting the fact that results from quasi‐static (QS) test of low‐rise reinforced concrete walls may be safely assumed as a lower limit of strength and displacement, and energy dissipation capacities are still scarce. The aim of this paper is to compare the seismic performance of 12 reinforced concrete walls for low‐rise housing: six prototype walls tested under QS‐cyclic loading and six models tested under shaking table excitations. Variables studied were wall geometry, type of concrete, web steel ratio, type of web reinforcement and testing method. Comparison of results from dynamic and QS‐cyclic tests indicated that stiffness and strength properties were dependent on the loading rate, the strength mechanisms associated with the failure mode, the low‐cycle fatigue, and the cumulative parameters, such as displacement demand and energy dissipated. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

12.
型钢混凝土剪力墙的抗震性能研究   总被引:2,自引:1,他引:1  
型钢混凝土剪力墙(亦称为SRC剪力墙)是一种新型的剪力墙,其抗弯承载力、抗剪承载力及延性均好于普通剪力墙。本文简要总结了近年来国内外关于型钢混凝土剪力墙抗震研究的成果。在此基础上,进行了较高轴压比下内藏钢桁架混凝土组合高剪力墙的抗震性能试验研究。试验研究表明,内藏钢桁架的存在明显改善了高轴压比下型钢混凝土高剪力墙的抗震性能。  相似文献   

13.
The paper under discussion presents a series of quasi‐static tests used to examine the behavior of steel reinforced concrete (SRC) walls subjected to high axial force and lateral cyclic loading. A total of six wall specimens were designed, including five SRC walls and one reinforced concrete (RC) wall. In the ‘Summary’ section of the discussed paper, the authors state that: ‘The use of SRC walls has gained popularity in the construction of high‐rise buildings because of their superior performance over conventional RC walls’. The authors also proposed that, the SRC wall specimens showed increased flexural strength and deformation capacity relative to their RC wall counterpart. The discussion is prompted to rectify some statements and conclusions of the paper under discussion. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

14.
The seismic performance of a self-centering precast reinforced concrete (RC) frame with shear walls was investigated in this paper. The lateral force resistance was provided by self-centering precast RC shear walls (SPCW), which utilize a combination of unbonded prestressed post-tensioned (PT) tendons and mild steel reinforcing bars for flexural resistance across base joints. The structures concentrated deformations at the bottom joints and the unbonded PT tendons provided the self-centering restoring force. A 1/3-scale model of a five-story self-centering RC frame with shear walls was designed and tested on a shake-table under a series of bi-directional earthquake excitations with increasing intensity. The acceleration response, roof displacement, inter-story drifts, residual drifts, shear force ratios, hysteresis curves, and local behaviour of the test specimen were analysed and evaluated. The results demonstrated that seismic performance of the test specimen was satisfactory in the plane of the shear wall; however, the structure sustained inter-story drift levels up to 2.45%. Negligible residual drifts were recorded after all applied earthquake excitations. Based on the shake-table test results, it is feasible to apply and popularize a self-centering precast RC frame with shear walls as a structural system in seismic regions.  相似文献   

15.
A modified force analogy method (MFAM) is developed to simulate the nonlinear inelastic response of reinforced concrete (RC) structures. Beam–column elements with three different plastic mechanisms are utilized to simulate inelastic response caused by moment and shear force. A multi‐linear hysteretic model is implemented to simulate the nonlinear inelastic response of RC member. The P‐Δ effect of the structure is also addressed in MFAM. Static and dynamic inelastic response of structure, damage condition and failure type for structural element, structural limit state and collapse time can also be simulated using MFAM. Compared with the general algorithm, the MFAM provides less computational time especially in the case of large structural system. It is also easier to be written as computer program. Three test data groups, which include cyclic loading test data of a non‐ductile RC bridge column, a two‐storey RC frame, and dynamic collapse test data of a non‐ductile RC portal frame, are selected to confirm the effectiveness of applying MFAM to simulate the inelastic behaviour of structures. Copyright © 2007 John Wiley & Sons, Ltd.  相似文献   

16.
Previous quasi-static cyclic tests of shear walls, which routinely used an incremental lateral displacement test protocol with a constant axial load, failed to reflect the character of moment-shear force interaction of prototype buildings. To study the effect of the moment-shear force interaction on the seismic performance of shear walls, three identical 2-story shear wall specimens with different loading patterns were constructed at 1/2 scale, to represent the lower portion of an 11-story high-rise building, and were tested under reversed cyclic loads. The axial force, shear force and bending moment were simultaneously applied to simulate the effects of gravity loads and earthquake excitations on the prototype. The axial force and bending moment delivered from the upper structure were applied to the top of the specimens by two vertical actuators, and the shear force was applied to the specimens by two horizontal actuators. A mixed force-displacement control test program was adopted to ensure that the bending moment and the lateral shear were increased proportionally. The experimental results show that the moment-shear force interaction had a significant effect on the failure pattern, hysteretic characteristics, ductility and energy dissipation of the specimens. It is recommended that moment-shear force interaction should be considered in the loading condition of RC shear wall substructures cyclic tests.  相似文献   

17.
Reinforced concrete (RC) structural walls with openings are the primary lateral‐load‐carrying elements utilized in many structures designed to resist earthquakes. A review of the technical literature shows that there is a considerable amount of uncertainty with regards to the elastic stiffness of these structures when subjected to seismic excitations. Current design practices often employ a stiffness reduction factor to deal with this uncertainty. In an attempt to develop additional information regarding the stiffness of these structures, this paper discusses an approach to determine the initial stiffness of RC structural walls with irregular openings and low aspect ratios. This approach would consider the effect of both flexural and shear deformations. As a part of this study, an analytical approach to determine stiffness was also developed and validated by comparing theoretical and experimental results obtained from six RC shear walls with irregular openings. Simple equations for assessing initial stiffness of RC structural walls with irregular openings are then proposed, based on these parametric case studies. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

18.
钢筋混凝土带暗支撑核心简体抗震性能试验研究   总被引:13,自引:3,他引:10  
本文在带暗支撑剪力墙研究的基础上,进一步提出了带暗支撑核心筒体,通1/6缩尺的1个带暗支撑筒体结构和1个普通筒体结构的低周反复荷载试验,比较分析了它们的承载力、刚度、延性、滞回特性、耗能能力及破坏机制。试验表明,带暗支撑筒体比普通筒体的抗震性能明显提高。  相似文献   

19.
钢筋混凝土核心筒体抗震性能试验研究   总被引:17,自引:5,他引:17  
本文对两组五个钢筋混凝土核心筒试件进行了低周反复荷载试验,研究了不同轴压比和剪跨比的核心筒破坏机理、承载能力、延性和耗能能力等方面的抗震性能。结果表明,轴压比对核心筒的抗震性能有较大影响。  相似文献   

20.
An existing two‐dimensional macroelement for reinforced concrete beam–column joints is extended to a three‐dimensional macroelement. The three‐dimensional macroelement for beam–column joints consists of six rigid interface plates and uniaxial springs for concrete, steel, and bond–slip, which model the inside of a beam–column joint. The mechanical models for the materials and the stiffness equation for the springs are also presented. To validate the model, we used test results from three slab–beam–column sub‐assemblages subjected to bi‐lateral cyclic load. It is revealed that the new joint model is capable of capturing the strength of beam–column joints and the bidirectional interaction in joint shear response, including the concentration of damage in the beam–column joint, the pinching nature in hysteretic behavior, the stiffness degradation, and strength deterioration resulting from cyclic and bidirectional loading. Copyright © 2017 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号