首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Groundwater is a very important component of water resources in coastal aquifers in Thoothukudi. It has been established that the groundwaters in the coastal zone of the Zirconium Complex, Pazhayakayal, Thoothukudi district, Tamilnadu, India, are subjected to wave and tidal impact. The groundwater quality was studied by hydrogeological methods, 2D electrical resistivity imaging (ERI) techniques (six profiles), 11 Wenner vertical electrical sounding (VES), and well log analysis. Also, nine geochemical water samples were taken from the study area. The 2D ERI and VES surveys were carried out using WGMD-4 Ltd., Chennai, resistivity meter, multicore cable, and multielectrodes with Wenner array. The collected resistivity data were interpreted using the Res2DINV software. The research shows that the groundwaters are the result of the paleoriver flow along the Tamirabarani Channel in the western area and of the seawater intrusion in the eastern area. The fresh water is characterized by resistivity of about 10–100 Ohm?m in the study area. The resistivity of 10–50 Ohm?m indicates that the subsurface section is made up of sand, clay, and caliche. Resistivity values of more than 200 Ohm?m are specific to sand dunes. The very low resistivity (<5 Ohm?m) layer might be due to the seawater intrusion in the study area. Six water samples from the well drilled in the coastal area were analyzed, which made it possible to determine the concentrations of major and trace elements in the groundwaters. These data were used to establish the seawater intrusion and coastal environment characteristics in the study area.  相似文献   

2.
A water resources database was developed and used to characterize the geological and hydrogeological settings of groundwater aquifers in the northern part of the United Arab Emirates. An intensive 2D Earth Resistivity Imaging (ERI) survey was conducted in selected areas to assess the available groundwater resources and delineate the salt-water intrusion. Drilling information of the existing monitoring wells as well as their records of water table elevations and groundwater salinity were used to measure the horizontal and vertical variations in lithology, degree of saturation, and groundwater salinity and thus to improve the interpretation of ERI data. The results of the chemical analyses of water samples collected from the wells along with the 2D ERI survey profiles were used to obtain an empirical relationship between the inferred earth resistivity and the amount of total dissolved solids. This relationship was used along with the true resistivity sections resulting from the inversion of 2D ERI data to identify and map three zones of water-bearing formation (fresh, brackish, and salt-water zones) in the coastal areas. The results indicated that the depth to the fresh-brackish interface exceeded 50 m at the upstream of the wadies and was in the order of 10 m or less in the vicinity of shoreline. Because of the high resistivity contrast between dry and water saturated fractured rocks; this method was very successful in detecting water-filled fractures and cavities in the carbonate aquifer. The application of this method was unsuccessful in clayey aquifers as it was not possible to isolate lenses of gravel and/or saturated with saline or brackish water from the surrounding clayey materials.  相似文献   

3.
 Geophysical methods, when integrated with soil chemical and hydrogeological methods, can be used to investigate groundwater contamination. Direct current (DC) resistivity geo-electrical sounding and very-low-frequency electromagnetic (VLF-EM) data were collected at an open waste site used by the municipality of the city of Isparta, Turkey. The groundwater at shallow depths in alluvium, which is composed of gravel, sand and clay, were expected to be hazardously contaminated under and around the open waste-disposal site, in which both household and industrial wastes are known to be disposed of improperly. In this study, we mapped the spread of groundwater contamination using a VLF-EM method, which allows fast and inexpensive data collection. The method complements the results of geo-electrical sounding. There is a good correlation between the results of the VLF-EM and the DC-resistivity methods employed for the investigation of subsurface structure of the site, where soil chemical and previous hydrogeological surveys have indicated high levels of chemical concentrations. Received: 17 January 2000 · Accepted: 12 August 2000  相似文献   

4.
Integrated geophysical techniques including resistivity image, vertical electrical sounding (VES), and seismic refraction have been conducted to investigate the Wadi Hanifah water system. The groundwater in Wadi Hanifah has problems caused by the high volumes of sewage water percolating into the ground. The combination of VES, resistivity image, and seismic refraction has made a valuable contribution to the identification of the interface between the contaminated and fresh water in Wadi Hanifah area. The contaminated groundwater has lower resistivity values than fresh groundwater due to the higher concentration of ions which reduces the resistivity. Resistivity image and sounding in this area clearly identified the nature of the lithological depth and proved useful at identifying water-bearing zones. Fresh groundwater was found in the study area at a depth of 100 m within the fractured limestone. Water-bearing zones occur in two aquifers, shallow contaminated water at 10 m depth in alluvial deposits and the deeper fresh water aquifer at a depth of about 100 m in fractured limestone. The interface between the contaminated water (sanitary water) and fresh water marked out horizontally at 100 m distance from the main channel and vertically at 20 m depth.  相似文献   

5.
Electrical resistivity surveying for delineating seawater intrusion was performed in the Dibdibba aquifer in the area between the cities of Al-Zubair–Safwan and Al-Zubair–Umm Qasr in the vicinity of Khor AL-Zubair Channel, Basrah governorate, southern Iraq. Fourteen 2D resistivity profiles with a total length of 14 km were collected in the study area. The resistivity sections were compared with lithological data extracted from 11 boreholes. Thirty-nine groundwater samples were collected within the area and analyzed for chemical constituents; internal hydrogeological reports and unpublished studies were also evaluated. Results reveal the existence of three major resistivity layers, ranging from 0.1 to 130 Ωm at various depths and locations. The first layer has very low electrical resistivity (0.1–5 Ωm) representing a layer saturated with saltwater intruded from Khor AL-Zubair Channel. The second layer shows resistivity in the range of 5–130 Ωm, attributed to a transition zone and an unaffected zone saturated with brackish groundwater. The last resistivity layer (<?3 Ωm) represents coarse-grain sediments saturated with saline groundwater. Furthermore, a hard clay bed (Jojab) appears with a resistivity of 3–7 Ωm in all 2D imaging lines within a depth of 20–28 m. Electrical conductivity (EC) measurements from seven wells collected in 2014 and 2016 show a positive EC difference increasing landward with an average increase of 1927 µS/cm. In addition, six chemical relationships (Na/Cl, [Ca?+?Mg]/[HCO3?+?SO4], SO4/HCO3, SO4/Cl, Mg/Ca and Cl/[HCO3?+?CO3]) are used to detect the source of salinity in groundwater. This study proves that extensive use of high-resolution 2D imaging sections, alongside lithological and hydrogeological data, can serve as a useful tool to delineate the boundaries between aquifers, identify hydraulic boundaries between groundwater with different salinities and allocate hard clay layers between the upper and lower Dibdibba aquifer. In general, the combination of 2D imaging and hydrochemistry enables conceptualization of the hydrogeological situation in the subsurface and characterization of the salinity source, here seawater intrusion, in the study area. There have been no studies published so far on the characteristics of saltwater intrusion in the study area, and this study is considered to be important for monitoring and studying the intrusion and regression of seawater.  相似文献   

6.
Surface geophysical methods were used to determine the locations of fracture zones in part of the hard rock area in Sonebhadra District of Uttar Pradesh, India. The survey comprises three DC resistivity profile using the gradient profiling technique and ten very low frequency electromagnetic (VLF-EM) traverses profiles. The methods were used over survey lines extending between 200 and 400 m; the results were correlated to locate fracture zones for the purpose of groundwater exploration. Qualitative interpretation of the VLF-EM was carried out using Fraser and Karous–Hjelt filters. The result of the interpretation revealed a number of subsurface zones with high real component current density that defines the potential subsurface features (probably fracture zones). The subsurface feature concurred with the low resistive zones indentified from the gradient resistivity profiling. The zones where further inferred quantitatively using data obtained from DC resistivity sounding at some selected anomalous points. The result obtained proves the efficiency of integrating both methods in detecting fractures zones in hard rock area.  相似文献   

7.
Integrated geoelectrical and hydrochemical surveys were used to investigate and delineate different types of groundwater in the Kuala Selangor alluvial aquifer. Previous hydrogeological borehole investigation showed that this aquifer contains several types of groundwater in relation to its salinity. The high salinity of the groundwater in some areas is believed to be due to either saltwater intrusion from the nearby sea or river infiltration during high tide season. The vertical electrical sounding (VES) method was employed to study and map the subsurface variation of resistivity in the area. For each sounding measurement, a total spread length of 300 m was obtained with a vertical depth penetration of about 60 to 75 m. Chemical analysis of the groundwater samples taken from both shallow and deep boreholes was carried out for the water quality determination. A total of 45 VES stations were succesfully established along three parallel roads with a direction almost perpendicular to the coastal line. The distance between stations varies from 1 to 2 km with a maximum length of about 60 km surveyed line. Results of the vertical electrical soundings as well as the hydrochemistry of the groundwater samples show that the soil and groundwater in the study area can be grouped into fresh and brackish water zones. The subsurface resisitivity sections derived from the VES study suggest that the area is dominated by brackish soil and groundwater zones, especially in the area towards the coast. This result appears to agree well with the groundwater pumped from boreholes scattered around in the area. Water drawn from boreholes near the coast showed higher salinity compared to the water pumped from inland boreholes. Chloride values greater than 250 mg/L are considered to represent the brackish zones whilst values less than 250 mg/L represents zones of fresh soil and groundwater.  相似文献   

8.
To delineate spatial extent of seawater intrusion in a small experimental watershed in the coastal area of Byunsan, Korea, electrical resistivity surveys with some evaluation core drillings and chemical analysis of groundwaters were conducted. The vertical electrical sounding (VES) method was applied, which is useful to identify variations in electrical characteristics of layered aquifers. The drilling logs identified a three-layered subsurface including reclamation soil, weathered layer and relatively fresh sedimentary bedrock. The upper two layers are the main water-bearing units in this area. A total of 30 electrical sounding curves corresponded mostly to the H type and they were further divided into three classes: highly conductive, intermediate, and low conductive, according to the observed resistivity values of the most conductive weathered layer. In addition, groundwater samples from 15 shallow monitoring wells were analyzed and thus grouped into two types based on HCO3/Cl and Ca/Na molar ratios with TDS levels, which differentiated groundwaters affected by seawater intrusion from those not or less affected. According to relationships between the three classes of the sounding curves and groundwater chemistry, locations of the monitoring wells with low HCO3/Cl and Ca/Na ionic ratios coincided with the area showing the highly conductive type curve, while those with the high ratios corresponded to the area showing low conductive curve type. Both the low electrical resistivity and the low ionic ratios indicated effects of seawater intrusion. From this study, it was demonstrated that the VES would be useful to delineate seawater intrusion in coastal areas.  相似文献   

9.
The groundwater hydrogeology of southern Tunisia emphasizes two main groundwater bodies so-called Zeuss-Koutine and south Gabes. These groundwater bodies yielding economically important storage of useful water present complex internal architecture and heterogeneity allowing exchange flows throughout permeable or/and fractured bodies. A geophysical survey using resistivity soundings was carried out along this area to describe in detail the field structure and the 3D extent of these groundwater bodies by the hydrogeological new data and detailed subsurface mapping based on resistivity sounding and seismic data. This survey discusses also the potentialities of some permeable layer in water storage and purposes potential favorable areas for optimum groundwater mining.  相似文献   

10.
Chandrabhaga basin of the Nagpur district is a part of the drought prone Vidarbha region of Maharashtra, India. This region is facing acute shortage of water for drinking and irrigation purposes. The basin is located at the eastern fringe of the Deccan traps consisting of volcanic rocks. Presently, dug wells penetrating composite layers of the weathered mantle and highly fractured rocks overlying stratified basaltic lava flows are the main source of water supply. However, water available in the dug wells is inadequate to meet the ever increasing demand for water causing considerable economic losses to the farming community. In this work, we present the results of an electrical resistivity tomography (ERT) survey carried out in the basin for the delineation of groundwater potential zones. Validity of the hydrogeological setup obtained from the ERT results has been confirmed by bore well drillings at two investigated sites. The study demonstrates the efficacy of the ERT technique in delineation of groundwater potential zones in the hydrogeologically complex basaltic terrain of the Deccan traps.  相似文献   

11.
The demand for water is rapidly increasing in Egypt, because of high population and agriculture production growth rate, which makes research of water resources necessary. The regional multi-aquifer system of the Miocene–Pleistocene age is discharged in Wadi El Natrun area. Intensive aquifer overexploitation and agricultural development in the area are related to groundwater quality deterioration. Hydrochemical and hydrogeological data was evaluated to determine the groundwater origin and quality in the south-eastern part of wadi, which appears to be more significant for water supply owing to lower groundwater salinity. The dominance of the high mineralised Cl groundwater type was found; however, also less mineralised SO4 and HCO3 types were identified there. Based on the ion relations, halite and gypsum dissolution and ion exchange are the most important hydrochemical processes forming the groundwater chemical composition. The Cl dominated groundwater matches the discharge part of the regional hydrogeological system. Contrary, the presence of HCO3 and SO4 hydrochemical types corresponds to the infiltration and transferring parts of the hydrogeological system indicating the presence of zones conducting low mineralised groundwater. The discharge area of the over-pumped aquifer in Wadi El-Natrun lies 23 m beneath the sea level with the shoreline being at the distance of 100 km, thus there is a real risk of seawater intrusion. Using the hydrochemical facies evolution diagram, four samples in the centre of the discharge area indicate advanced seawater intrusion. The zones of the highest demand for groundwater quality protection were indicated based on a spatial pattern of hydrogeochemical composition.  相似文献   

12.
This study demonstrates the strength of R-mode factor analysis and Q-mode hierarchical cluster analysis in determining spatial groundwater salinity groups in southeastern Ghana. Three hundred and eighty three (383) groundwater samples were taken from six hydrogeological terrains and surface water bodies and analyzed for the concentrations of the major ions, electrical conductivity and pH. Q-mode hierarchical cluster analysis and R-mode factor analysis were respectively used to spatially classify groundwater samples and determine the probable sources of variation in groundwater salinity. The quality of groundwater for irrigation was then determined using three major indices. The analyses revealed two major sources of variation in groundwater salinity: silicate mineral weathering on one hand, and seawater intrusion and anthropogenic contamination on the other. A plot of the factor scores for the two major sources of variation in the salinity revealed trends which can be used in hydrogeological mapping and assist in drilling potable water boreholes in southeastern Ghana. This study also revealed four major spatial groundwater groups: low salinity, acidic groundwaters which are mainly derived from the Birimian and Togo Series aquifers; low salinity, moderate to neutral pH groundwaters which draw membership mainly from samples of the Voltaian, Buem and Cape Coast granitoids; very high salinity waters which are not suitable for most domestic and irrigation purposes and are mainly from the Keta Basin aquifers; and intermediate salinity groundwaters consisting of groundwater from the Keta basin aquifers with minor contributions from the other major terrains. The major water type identified in this study is the Ca–Mg–HCO3 type, which degrades into predominantly Na–Cl–SO4 more saline groundwaters towards the coast.  相似文献   

13.
Vertical electrical sounding (VES’) surveys and chemical analyses of groundwater have been executed in the coastal plain of Acquedolci (Northern Sicily), with the aim to circumscribe seawater intrusion phenomena. This urbanized area is representative of a more general problem interesting most of Mediterranean littoral areas, where intensive overdraft favors a heavy seawater intrusion through the coastline. Aquifer resistivity seems decisively to be conditioned by the chlorine and magnesium content in the main aquifer of the region. Schlumberger VES’, together with piezometric and chemical–physical information of groundwater, allowed us to perform hydrogeological and geophysical elaborations, to propose the occurrence of a relatively narrow belt marked by fresh–salt water mixing. In the considered plain, pollution risk studies have been already realized by authors with the proposal to identify—by parametric and synthetic zoning of significant hydrogeological elements—the most vulnerable sectors. In detail, an intrinsic vulnerability mapping has been already performed, applying the well-known SINTACS system. This paper intends to give—in this sector of Sicily—an example of integration of different methodologies, showing the role of geophysics to describe the degradation of aquifers on the whole as well as to assess their pollution risk better.  相似文献   

14.
The use of resistivity sounding and two-dimensional (2-D) resistivity imaging was investigated with the aim of delineating and estimating the groundwater potential in Keffi area. Rock types identified are mainly gneisses and granites. Twenty-five resistivity soundings employing the Schlumberger electrode array were conducted across the area. Resistivity sounding data obtained were interpreted using partial curve matching approach and 1-D inversion algorithm, RESIST version 1.0. The 2-D resistivity imaging was also carried out along two traverses using dipole–dipole array, and the data obtained were subjected to finite element method modeling using DIPRO inversion algorithm to produce a two-dimensional subsurface geological model. Interpretation of results showed three to four geoelectrical layers. Layer thickness values were generally less than 2 m for collapsed zone, and ranged from 5 to 30 m for weathered bedrock (saprolite). Two major aquifer units, namely weathered bedrock (saprolite) aquifer and fractured bedrock (saprock) aquifer, have been delineated with the latter usually occurring beneath the former in most areas. Aquifer potentials in the area were estimated using simple schemes that involved the use of three geoelectrical parameters, namely: depth to fresh bedrock, weathered bedrock (saprolite) resistivity and fractured bedrock (saprock) resistivity. The assessment delineated the area into prospective high, medium and low groundwater potential zones.  相似文献   

15.
太行山前的大多数石灰岩受火成岩的侵入,造成这些地区的地下水分布极不均匀,施工成井率很低。为了合理有效地开发地下水资源,在工作区进行水文地质调查的基础上,垂直于主构造线方向布置了3条电阻率法勘探剖面线,运用对称四极电阻率测深法,分别测量了视电阻率值。通过绘制视电阻率等值线断面图,定性和定量解释火成岩侵入的石灰岩地区地下富水带在视电阻率等值线图上的表现形态,准确的确定了井位。通过钻探工程验证,水井的出水量较为理想,与物探推断分析得出来的结论吻合良好。在这类地区开展电法找水,研究水文地质条件是基础,野外工作布置要灵活,深刻分析视电阻率等值线的异常形态是关键。   相似文献   

16.
 One-third of the population of Oman depends upon groundwater extracted from the alluvium of the Batinah Plain, on the coast of the Gulf of Oman. Deep geophysical exploration techniques were used to determine the depth and nature of the alluvium and the boundaries of the aquifer. The base and structural controls of the alluvial basin at its contact with Tertiary marine sediments and Cretaceous ophiolite were mapped with seismic reflection data, recorded originally for oil exploration. The base of the alluvium dips northward from the foothills of the Northern Oman Mountains, reaching a maximum depth of 2000 m at the coast. The varying facies of the alluvium are grossly characterised by different, overlapping ranges of electrical resistivity, depending largely on the clay content and degree of cementation. Resistivities near the coast are reduced by saline intrusion. These variations of resistivity were mapped with time-domain electromagnetic sounding along 400 km of profile, to distinguish among the three zones of the alluvial aquifer. The wedge of saline intrusion was also delineated, up to 10 km from the coast. The thickness of the saturated gravel aquifer ranges from 20–160 m in an area greater than 600 km2. Received, April 1997 · Revised, January 1998 · Accepted, April 1998  相似文献   

17.
The Dhanbad district in Jharkhand faces acute water scarcity and is chronically drought-prone. The groundwater resources in the area have not been fully exploited. The present study was undertaken to evaluate the groundwater prospective zones. Landsat-5 Multi Spectral Scanner (MSS) data of band 2 and band 4 and false colour composite (FCC) of band 2, 3, 4 were interpreted visually to differentiate different hydromorphogeological units and to delineate the major trends of lineaments. The different geomorphic features identified are linear ridges, residual hills, and pediplain, buried pediment and dissected pediplain, besides lineaments. The study shows that the pediplain and buried pediments are promising zones for groundwater prospecting. The occurrence and movement of groundwater is restricted to the unconsolidated material, weathered and fractured rocks. For the selection of tube well sites, geoelectrical resistivity investigations have been carried out at the sites, which were found suitable based on hydrogeomorphological and hydrogeological studies. Twenty-six Vertical Electrical Soundings (VES) have been carried out by using Schlumberger electrode configuration, which have brought out 3 to 7 layered sub-surface layers. The resistivity of water-bearing weathered/fractured rocks varies from 120–150 ohm m. The integrated studies have revealed that the blue colour zones are most promising for groundwater exploration and dug wells may be dug up to depths of 30±5m.  相似文献   

18.
为了掌握中生代构造运动以来鲁中山区岩溶地下水富集规律,以莱芜盆地为例,通过水文地质调查及数据统计分析、钻探施工、地质露头观测、碳酸盐岩可溶组分分析等方法,对中生代构造活动特征、岩浆活动特征,及其对岩溶地下水赋存规律的控制作用进行研究。结果表明:鲁中山区具有典型盆-山结构水文地质特征,盆地南北两侧水文地质特征不尽相同;区域滑脱构造形成的层间虚脱、空隙、碎裂岩带,使得鲁中山区下寒武统朱砂洞组含水层表现为"似层状"特征;热液混合岩溶作用形成的溶蚀裂隙、洞穴可成为岩溶地下水良好的赋存空间;由中生代滑脱构造及热液岩溶活动形成的岩溶介质环境受同期或后期层间溶蚀裂隙及断层沟通,形成立体的岩溶地下水网络。岩溶地下水沿该网络径流、富集,形成鲁中山区特有的岩溶地下水赋存特征。  相似文献   

19.
Electrical resistivity methods are applied extensively for shallow sub-surface objectives but it has constraints in distinguishing the chemical characteristics of the medium. However, this complexity can be resolved by integrated investigations where geophysical anomaly would be validated with hydro-geochemical data. The present study highlights the notable importance of integrated geophysical and hydrogeological investigations in demarcating sub-surface pollution due to saline water intrusion and industrial effluents at Cuddalore coast in India. Geophysical scanning encompassing a total of 35 vertical electrical sounding (VES) were validated with drilling lithologs, water level and water quality parameters from a network of 125 observation wells at a test site of 17 km2. To understand the spatial variation of sub-surface contamination, two profiles of apparent resistivity sections were generated covering VES points parallel to the coast. Results revealed that, the low order of resistivity range 3 to 10 Ω-m (up to 30–40 m depth) and total dissolved solids range 2000 to 10,000 mg/l of groundwater reflects sub-surface contamination but cannot distinguish kind of salinity which is further verified by chemical analysis of Ca2+ (1200–2041 mg/l), SO4 2? (3000–9480 mg/l) which confirms the gypsum pollution and Na+ (750–1000 mg/l), Cl? (1000–2000 mg/l) designate the marine water contamination. Further, static groundwater head measurements demarcate the study area into above mean sea level (MSL) and below MSL zones. This study has provided a rapid and comprehensive picture about spatial variations of groundwater contamination which can help in planning, protection and safe management of coastal aquifers in India and worldwide.  相似文献   

20.
The Quaternary aquifer of Wadi Ham, UAE has been overexploited during the last two decades to meet the increasing water demands. As a result, the dynamic balance between freshwater and seawater has been disturbed and the quality of the groundwater has deteriorated. In this paper, a 2D earth resistivity survey was conducted in Wadi Ham in the area between Fujairah and Kalba to delineate the seawater intrusion. Existing monitoring wells were used to measure the horizontal and vertical variations in water salinity and thus to improve the interpretation of earth resistivity imaging data. Results of vertical electrical soundings and chemical analyses of collected water samples were used to obtain an empirical relationship between the inferred earth resistivity and the amount of total dissolved solids. This relationship was used along with the true resistivity sections resulting from the inversion of 2D resistivity data to identify three zones of water-bearing formation (fresh, brackish, and salt-water zones). Along the four 2D resistivity profiles, the depth to the fresh-brackish interface exceeded 50 m at the western part of the area and was in the order of 10 m or less in the eastern side near the shoreline. Depth to the brackish-saline water interface reached about 70 m in the western side and was in the order of 20 m in the eastern side. The thickness of the fresh water zone decreases considerably in the farming areas toward Kalba and thus the degree of seawater intrusion increases.  相似文献   