1.
A design procedure for seismic retrofitting of concentrically and eccentrically braced frame buildings is proposed and validated in this paper. Rocking walls are added to the existing system to ensure an almost uniform distribution of the interstorey displacement in elevation. To achieve direct and efficient control over the seismic performance, the design procedure is founded on the displacement‐based approach and makes use of overdamped elastic response spectra. The top displacement capacity of the building is evaluated based on a rigid lateral deformed configuration of the structure and on the ductility capacity of the dissipative members of the braced frames. The equivalent viscous damping ratio of the braced structure with rocking walls is calculated based on semi‐empirical relationships specifically calibrated in this paper for concentrically and eccentrically braced frames. If the equivalent viscous damping ratio of the structure is lower than the required equivalent viscous damping ratio, viscous dampers are added and arranged between the rocking walls and adjacent reaction columns. The design internal forces of the rocking walls are evaluated considering the contributions of more than one mode of vibration. The proposed design procedure is applied to a large set of archetype braced frame buildings and its effectiveness verified by nonlinear dynamic analysis.  相似文献   

2.
Viscous and other damping devices are often used as elements of seismic isolation systems. Despite the widespread application of nonlinear viscous systems particularly in Japan (with fewer applications in the USA and Taiwan), the application of viscous damping devices in isolation systems in the USA progressed intentionally toward the use of supplementary linear viscous devices due to the advantages offered by these devices. This paper presents experimental results on the behavior of seismically isolated structures with low damping elastomeric (LDE) and single friction pendulum (SFP) bearings with and without linear and nonlinear viscous dampers. The isolation systems are tested within a six‐story structure configured as moment frame and then again as braced frame. Emphasis is placed both on the acquisition of data related to the structural system (drifts, story shear forces, and isolator displacements) and on non‐structural systems (floor accelerations, floor spectral accelerations, and floor velocities). Moreover, the accuracy of analytical prediction of response is investigated based on the results of a total of 227 experiments, using 14 historic ground motions of far‐fault and near‐fault characteristics, on flexible moment frame and stiff braced frame structures isolated with LDE or SFP bearings and linear or nonlinear viscous dampers. It is concluded that when damping is needed to reduce displacement demands in the isolation system, linear viscous damping results in the least detrimental effect on the isolated structure. Moreover, the study concludes that the analytical prediction of peak floor accelerations and floor response spectra may contain errors that need to be considered when designing secondary systems. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

3.
The concentrically braced frame (CBF) structure is one of the most efficient steel structural systems to resist earthquakes. This system can dissipate energy during earthquakes through braces, which are expected to yield in tension and buckle in compression, while all other elements such as columns, beams and connections are expected to behave elastically. In this paper, the performance of single‐storey CBFs is assessed with nonlinear time‐history analysis, where a robust numerical model that simulates the behaviour of shake table tests is developed. The numerical model of the brace element used in the analysis was calibrated using data measured in physical tests on brace members subjected to cyclic loading. The model is then validated by comparing predictions from nonlinear time‐history analysis to measured performance of brace members in full scale shake table tests. Furthermore, the sensitivity of the performance of the CBF to different earthquake ground motions is investigated by subjecting the CBF to eight ground motions that have been scaled to have similar displacement response spectra. The comparative assessments presented in this work indicate that these developed numerical models can accurately capture the salient features related to the seismic behaviour of CBFs. A good agreement is found between the performance of the numerical and physical models in terms of maximum displacement, base shear force, energy dissipated and the equivalent viscous damping. The energy dissipated and, more particular, the equivalent viscous damping, are important parameters required when developing an accurate displacement‐based design methodology for CBFs subjected to earthquake loading. In this study, a relatively good prediction of the equivalent viscous damping is obtained from the numerical model when compared with data measured during the shake table tests. However, it was found that already established equations to determine the equivalent viscous damping of CBFs may give closer values to those obtained from the physical tests. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

4.
In this paper the theory of plastic mechanism control is presented for moment resisting frame–concentrically braced frames dual systems, i.e. for structural systems combined by moment resisting frames and concentrically braced frames. It is aimed at the design of structures failing in global mode, i.e. whose collapse mechanism is characterised by the yielding of all the tensile diagonals and the occurrence of buckling in the compressed ones, and by plastic hinge formation at all the beam ends and at the base of first storey columns. The proposed methodology is based on the application of the kinematic theorem of plastic collapse, by imposing that the global mechanism equilibrium curve has to lie below all the other equilibrium curves corresponding to undesired mechanisms. The practical application of the design methodology is illustrated by means of a worked example. In addition, the results of a non-linear static pushover and dynamic analyses of the designed structure are also discussed in order to demonstrate the effectiveness of the proposed design procedure.  相似文献   

5.
A displacement-based design procedure using hysteretic damped braces (HYDBs) is proposed for the seismic retrofitting of unsymmetric-plan structures. An expression of the viscous damping equivalent to the hysteretic energy dissipated by the damped braced frame is proposed under bidirectional seismic loads, where corrective factors are assumed as a function of design parameters of the HYDBs. To this end, the nonlinear dynamic analysis of an equivalent two degree of freedom system is firstly carried out on seven pairs of real ground motions whose displacement response spectra match, on average, the design spectrum proposed by the Italian seismic code for a high-risk seismic zone and a medium subsoil class. Then, the extended N2 method considered by the European seismic code, which combines the nonlinear static analysis along the in-plan principal directions of the structure with elastic modal analysis, is adopted to evaluate the higher mode torsional effects. The town hall of Spilinga (Italy), a reinforced concrete (r.c.) framed building with an L-shaped plan, is supposed to be retrofitted with HYDBs. Six structural solutions are compared considering two alternative in-plan distributions of the HYDBs, to eliminate (elastic) torsional effects, and three design values of the frame ductility combined with a constant design value of the damper ductility. To check the effectiveness and reliability of the DBD procedure, the nonlinear static analysis of the test structures is carried out, by evaluating the vulnerability index of r.c. frame members and the ductility demand of HYDBs for different in-plan directions of the seismic loads.  相似文献   

6.
This paper presents a direct displacement-based design procedure for seismic retrofit of existing buildings using nonlinear viscous dampers according to equivalent linear systems. Unlike conventional methods, the equivalent linear viscous damping provided by the nonlinear viscous dampers is derived based on the assumption that the average energy dissipated between the linear and the nonlinear viscous dampers is equal. Also, the equivalent period and viscous damping for the equivalent linear systems which are used for representing the behavior of bare frames (the buildings without dampers) are derived from the concept of average storage energy and average dissipated energy, respectively. It is shown from nonlinear time-history analyses that the nonlinear action of the retrofitted structures can be reasonably captured by the presented direct displacement-based procedure.  相似文献   

7.
Hybrid simulation is a testing methodology that combines laboratory and analytical simulation to evaluate seismic response of complex structural framing systems. One or more portions of the structure, which may be difficult to model numerically or have properties that have not been examined before, are tested in one or more laboratories, whereas the remainder of the structure is modeled in software using one or more computers. These separate portions are assembled such that combined dynamic response of the hybrid model to excitation is computed using a time‐stepping procedure. A hybrid simulation conducted to examine the seismic response of a type of steel concentrically braced frame, the suspended‐zipper‐braced frame, is presented. The hybrid simulation testing architecture, hybrid model, test setup, solution algorithm, and the seismic response of the suspended‐zipper‐braced frame hybrid model are discussed. Accuracy of this hybrid simulation is examined by comparing hybrid and computer‐only simulations and the errors are quantified using an energy‐based approach. This comparison indicates that the deployed hybrid simulation method can be used to accurately model the seismic response of a complex structural system such as the zipper‐braced frame. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

8.
<正>This paper describes shaking table tests of a 1:12 scale model of a special concentrically braced steel frame with pinned connections,which was fabricated according to a one-bay braced frame selected from a typical main factory building of a large thermal power plant.In order to investigate the seismic performance of this type of structure,several ground motion accelerations with different levels for seismic intensityⅧ,based on the Chinese Code for Seismic Design of Buildings,were selected to excite the model.The results show that the design methods of the members and the connections are adequate and that the structural system will perform well in regions of high seismicity.In addition to the tests,numerical simulations were also conducted and the results showed good agreement with the test results.Thus,the numerical model is shown to be accurate and the beam element can be used to model this structural system.  相似文献   

9.
在地震来临时,一般假设建筑结构同时受到两个正交水平方向分量与一个竖向分量的地震动作用。双向水平地震效应组合方法用于估计两个正交水平分量地震动同时作用时结构的内力效应。本文主要对我国与美国抗震设计规范中规定使用的平方和开平方根(SRSS)方法与百分比组合方法的有效性进行了评估。首先,对比了我国与美国规范在考虑双向水平地震效应时的适用情况及相关规定上的异同。以一4层中心支撑-框架结构为工程案例,考虑两国规范在适用情况上的规定,设置了三个结构布置方案。对三个结构布置方案建立有限元模型,选取22组地震动,开展了动力时程分析。提出了针对SRSS方法与百分比组合方法的评估指标,基于时程分析结果,发展了双向水平地震效应组合的概率性评估方法。评估结果表明:SRSS方法与百分比组合方法用于平面扭转不规则结构的设计较为保守。在简化组合规则的适用条件上,美国规范对平面扭转不规则结构不进行考虑有一定的合理性。建议我国规范对中心支撑-框架结构中含双向受压柱的设计要求考虑双向水平地震效应组合。  相似文献   

10.
An Erratum has been published for this article in Earthquake Engineering and Structural Dynamics 2000; 29(7):1076. Two interrelated issues related to the design of non-linear viscous dampers are considered in this paper: structural velocities and equivalent viscous damping. As the effectiveness of non-linear viscous dampers is highly dependent on operating velocities, it is important to have reliable estimates of the true velocity in the device. This should be based on the actual relative structural velocity and not the commonly misused spectral pseudo-velocity. This is because if spectral pseudo-velocities (PSV) are used, they are based on design displacements (Sv=ω0Sd) and are thus fundamentally different from the actual relative structural velocity. This paper examines the difference between these two velocities, and based on an extensive study of historical earthquake motions proposes empirical relations that permit the designer to transform the well-known spectral pseudo-velocity to an actual relative structural velocity for use in design. Non-linear static analysis procedures recommended in current guidelines for the design of structural systems with supplement damping devices are based on converting rate-dependent device properties into equivalent viscous damping properties based on an equivalent energy consumption approach. Owing to the non-linear velocity dependence of supplemental devices, an alternative approach for converting energy dissipation into equivalent viscous damping is advanced in this paper that is based upon power consumption considerations. The concept of a normalized damper capacity (ϵ) is then introduced and a simple design procedure which incorporates power equivalent linear damping based on actual structural velocities is presented. Copyright © 1999 John Wiley & Sons, Ltd.  相似文献   

11.
本文讨论了利用黏性阻尼和复阻尼模型求解结构动力响应的方法;按相同的阻尼比,分别采用复阻尼模型和黏性阻尼模型计算了两个框架结构在不同地震波作用下的响应,并将结果进行对比,分析了两种不同的阻尼模型对结构动力响应的影响。结果表明,采用不同类型的阻尼对结构响应影响很大。  相似文献   

12.
结构阻尼与材料阻尼的关系   总被引:4,自引:1,他引:4  
针对固体材料在弹性阶段的内阻尼,采用材料粘弹性本构关系,通过有限单元法建立了考虑剪切变形影响的杆单元阻尼矩阵,得到了材料拉压粘滞系数和剪切粘滞系数之间的关系。我们可以通过实验测试材料的损耗因子或粘滞阻尼系数(材料阻尼),像结构质量矩阵、刚度矩阵一样通过比较确切的计算得到弹性阶段结构内阻尼的阻尼矩阵(结构阻尼),而且此阻尼矩阵既基于材料阻尼实验测试,又便于数学处理,且物理意义明确。其次,本文分析了材料阻尼对结构阻尼比影响,得到了材料损耗因子与结构模态阻尼比间的关系,并通过10层钢筋混凝土剪切型框架结构进一步给出了具体的数值结果。  相似文献   

13.
In the recent past, suspended zipper‐braced frames were proposed to avoid one‐storey collapse mechanisms and dynamic instability under severe ground motions. In this paper, the design procedure suggested by Yang et al. is first slightly modified to conform to the design approach and capacity design rules stipulated in Eurocode 8 for concentrically braced frames. The procedure is applied to a set of suspended zipper‐braced frames with different number of storeys and founded on either soft or rock soil. The structural response of these frames is analysed to highlight qualities and deficiencies and to assess the critics reported by other researchers with regard to the design procedure by Yang et al. Then, improvements are proposed to this procedure to enhance the energy dissipation of the chevron braces and the response of the structural system as well. The effectiveness of the design proposals is evaluated by incremental dynamic analysis on structures with different geometric properties, gravity loads and soil of foundation. Copyright © 2017 John Wiley & Sons, Ltd.  相似文献   

14.
A new direct performance‐based design method utilizing design tools called performance‐spectra (P‐Spectra) for low‐rise to medium‐rise frame structures incorporating supplemental damping devices is presented. P‐Spectra are graphic tools that relate the responses of nonlinear SDOF systems with supplemental dampers to various damping parameters and dynamic system properties that structural designers can control. These tools integrate multiple response quantities that are important to the performance of a structure into a single compact graphical format to facilitate direct comparison of different potential solutions that satisfy a set of predetermined performance objectives under various levels of seismic hazard. An SDOF to MDOF transformation procedure that defines the required supplemental damping properties for the MDOF structure to achieve the response defined by the target SDOF system is also presented for hysteretic, linear viscous and viscoelastic damping devices. Using nonlinear time‐history analyses of idealized shear structures, the accuracy of the transformation procedure is verified. A seismic performance upgrade design example is presented to demonstrate the usefulness of the proposed method for achieving design performance goals using supplemental damping devices. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

15.
A displacement-based design (DBD) procedure aiming to proportion hysteretic damped braces (HYDBs) in order to attain, for a specific level of seismic intensity, a designated performance level of a structure is proposed for the retrofitting of framed buildings. A key step for the reliability of the DBD procedure is the selection of the equivalent viscous damping in order to account for the energy dissipated by the damped braced frame. In this paper, expressions of the equivalent damping are obtained considering the energy dissipated by the HYDBs and the framed structure. To this end, dynamic analyses of an equivalent single degree of freedom system, whose response is idealized by a trilinear model, are carried out considering real accelerograms matching, on the average, Eurocode 8 (EC8) response spectrum for a medium subsoil class. Then, a three-storey reinforced concrete (r.c.) framed structure of a school building, designed in a medium-risk seismic region according to the Italian code in force in 1975, is supposed as retrofitted as if in a high-risk seismic region of the current seismic code (NTC08) by the insertion of HYDBs. Nonlinear static analyses are carried out to evaluate the vulnerability of the primary structure, characterized by the lack of interior girders along the floor slab direction, and to select optimal properties of the HYDBs. The effectiveness of the retrofitting solutions is checked referring to nonlinear dynamic analyses, considering artificially generated accelerograms whose response spectra match those adopted by NTC08 for the earthquake design levels corresponding to the serviceability and ultimate limit states.  相似文献   

16.
The determination of displacement demands for masonry buildings subjected to seismic action is a key issue in the performance-based assessment and design of such structures. A technique for the definition of single-degree-of-freedom (SDOF) nonlinear systems that approximates the global behaviour of multi-degree-of-freedom (MDOF) 3D structural models has been developed in order to provide useful information on the dependency of displacement demand on different seismic intensity measures. The definition of SDOF system properties is based on the dynamic equivalence of the elastic properties (vibration period and viscous damping) and on the comparability with nonlinear hysteretic behaviour obtained by cyclic pushover analysis on MDOF models. The MDOF systems are based on a nonlinear macroelement model that is able to reproduce the in-plane shear and flexural cyclic behaviour of pier and spandrel elements. For the complete MDOF models an equivalent frame modelling technique was used. The equivalent SDOF system was modelled using a suitable nonlinear spring comprised of two macroelements in parallel. This allows for a simple calibration of the hysteretic response of the SDOF by suitably proportioning the contributions of flexure-dominated and shear-dominated responses. The comparison of results in terms of maximum displacements obtained for the SDOF and MDOF systems demonstrates the feasibility and reliability of the proposed approach. The comparisons between MDOF and equivalent SDOF systems, carried out for several building prototypes, were based on the results of time-history analyses performed with a large database of natural records covering a wide range of magnitude, distance and local soil conditions. The use of unscaled natural accelerograms allowed the displacement demand to be expressed as a function of different ground motion parameters allowing for the study of their relative influence on the displacement demand for masonry structures.  相似文献   

17.
针对现有附加有效阻尼比计算方法存在的问题,本文从能量的角度揭示了阻尼比对结构影响的机理。从结构设计的角度,提出一种在时程分析下基于楼层剪力的消能减震结构等效阻尼比计算方法。对布置黏滞阻尼器和软钢阻尼器的消能减震模型,采用本文提出的等效阻尼比计算方法,建立等效结构进行结构响应对比。结果表明,由该计算方法得到的等效阻尼比能够准确地评估阻尼器在结构中的耗能效果,建立的等效结构能够准确反映消能减震结构实际情况。基于楼层剪力的等效阻尼比计算方法通过等效结构楼层剪力大于或等于消能减震结构楼层剪力判断迭代完成,该方法计算过程不涉及阻尼器参数及结构形式,适用于所有阻尼器类型与结构类型。计算得到的等效结构进行设计能够确保结构设计的安全。  相似文献   

18.
This paper deals with the estimation of peak inelastic displacements of SDOF systems, representative of typical steel structures, under constant relative strength scenarios. Mean inelastic deformation demands on bilinear systems (simulating moment resisting frames) are considered as the basis for comparative purposes. Additional SDOF models representing partially‐restrained and concentrically‐braced (CB) frames are introduced and employed to assess the influence of different force‐displacement relationships on peak inelastic displacement ratios. The studies presented in this paper illustrate that the ratio between the overall yield strength and the strength during pinching intervals is the main factor governing the inelastic deformations of partially‐restrained models and leading to significant differences when compared with predictions based on bilinear structures, especially in the short‐period range. It is also shown that the response of CB systems can differ significantly from other pinching models when subjected to low or moderate levels of seismic demand, highlighting the necessity of employing dedicated models for studying the response of CB structures. Particular attention is also given to the influence of a number of scalar parameters that characterise the frequency content of the ground motion on the estimated peak displacement ratios. The relative merits of using the average spectral period Taver, mean period Tm, predominant period Tg, characteristic period Tc and smoothed spectral predominant period To of the earthquake ground motion, are assessed. This paper demonstrates that the predominant period, defined as the period at which the input energy is maximum throughout the period range, is the most suitable frequency content scalar parameter for reducing the variability in displacement estimations. Finally, noniterative equivalent linearisation expressions based on the secant period and equivalent damping ratios are presented and verified for the prediction of peak deformation demands in steel structures. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

19.
A new earthquake resistant structural system for multi‐storey frame structures, based on a dual function of its bracing components, is developed. This consists of a hysteretic damper device and a cross‐bracing mechanism with a kinetic closed circuit, working only in tension, so that cable members can be used for this purpose. Solutions are presented regarding the connections' design of three types of structural frame system, that are concerned throughout the study: braced moment free frame, braced moment resisting frame with moment free supports, and with moment resisting supports. The dynamic behaviour of the system is investigated on the basis of an SDOF model, and based on the response spectra method an approximate design approach of the controlled structures is shown. From the time history analysis of the structural systems for the El Centro earthquake the areas of appropriate stiffness relations of the frames to the hysteretic dampers and the cable braces are deduced, so that the energy dissipation of the system may be controlled by the damper‐cable bracing mechanism. Based on the results of these studies, a predesign approach is developed for the implementation of the control system in frame structures. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

20.
The response of structures subjected to seismic actions is always influenced by P–Δ effects. The importance of this effect is generally modest for structures experiencing an elastic response but often relevant for structures responding well within the inelastic range of behaviour. Seismic codes indicate that P–Δ effects may be counterbalanced through an increase in the structural strength required by a first order analysis. This increase is calculated by means of a strength amplification factor. The expressions suggested in codes for this factor are simplistic and often criticized by researchers. In this paper, the effectiveness of some of the provisions reported in the literature or suggested in seismic codes is evaluated on single degree of freedom systems with different periods of vibration. As suggested by past studies, attention is focused on the influence of the interstorey drift sensitivity coefficient, significant duration of the ground motion, class of the site soil, displacement ductility and equivalent viscous damping ratio of the system. Finally, an accurate expression of the strength amplification factor is proposed. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   