首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 453 毫秒
1.
The time domain electromagnetic method (TDEM) is applied to monitor, to delineate and to map the saltwater intrusion zones in the Mediterranean Plio‐Quaternary aquifer. Forty‐two TDEM soundings were carried out in the coastal plain of Nabeul–Hammamet region (NE Tunisia). TDEM resistivity data were correlated with the existing borehole logging data to assign them to a particular lithology and to provide information about the position of the freshwater–seawater transition zone. The geoelectric sections showing the vertical configuration of seawater intrusion, with the brackish‐salty‐saturated zones, have a resistivity ranging from ~0.1 to 5 Ω?m and are detected at a depth lower than 1.5 m. The salinized zones are located at Nabeul (Sidi Moussa, Sidi El Mahrsi, Al Gasba and Mrazgua) and at Hammamet (Touristic zone of Hammamet north and south, Baraket Essahel) and reached a distance of 4 km from the coastline, indicating a severe state for the aquifer in these zones. These TDEM results are confirmed by the increase of chloride concentration content in the analysed water samples of monitoring wells. Moreover, in the northeastern part, the presence of a saltwater front located far from the coast and along the NW–SE major surface fault can be explained by two hypothesis: (i) this fault seems to provide a conduit for seawater to move readily towards the water wells and (ii) the clay and gypsum infiltration of marine Messinian deposits through the fault plane leads to low resistivities. Finally, it comes out from this study that TDEM survey has successfully depicted salinized zones of this coastal aquifer. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

2.
The Picillo Farm, EPA Superfund Site, in western Rhode Island was an unauthorized disposal site of hazardous organic chemicals. Predominantly organic contaminants have entered an aquifer comprised of layered glacial deposits and fractured bedrock and spread past the site boundaries with groundwater flow. Hydraulic conductivities in the glacial deposits range over two orders of magnitude and fractures and faults in the granitic bedrock further complicate the spreading of contaminants. Monitoring wells delineate two plumes that extend towards a fault-controlled valley with lakes and wetlands; one to the northwest and the other to the southwest. In this investigation we studied the electrical characteristics of both plumes.One dimensional Schlumberger depth soundings were conducted along several profile lines over the plumes and compared to those over non-contaminated sections of the site. With regard to the southwestern plume, high formation factors (ratio of bulk layer to pore water resistivity) between 12 and 45 were observed compared to values between 2.5 and 7.7 measured over the non-contaminated sections. Also, high values (> 5) of vertical electrical anisotropy (ratio of geoelectrically determined depth to high resistivity bedrock to drilled depth to bedrock) were measured over the contaminated part of the site. These values are extremely high compared to other non-contaminated sites (range: 2 to 3) in glacial stream channels of southern Rhode Island. Geoelectric measurements were affected by lateral effects. However, the consistency of high formation factors (11 to 35) and high vertical anisotropies (3 to 5) over the southwestern plume in comparison to low formation factors (3 to 8) and vertical anisotropies (1 to 1.5) over non-contaminated sites represents a marked difference between both sites. Overall, the Schlumberger depth soundings are less susceptible to near-surface lateral inhomogeneities than expected from other geoelectrical methods. Also, the disadvantage of a 1D interpretation was compensated by estimating resistivity and thickness ranges within the concept of non-uniqueness using the Dar Zarrouk parameters (Maillet, R., 1947. The fundamental equations of electrical prospecting. Geophysics, 12(4): 529–556.).The results over the northwestern plume, i.e. an area with higher contaminant concentration than the southwestern plume, were mixed and showed no consistent trends. Predominantly reducing conditions, as indicated by the presence of soluble ferric (FeII) iron hydroxides in ground water samples, increased the electrical conductivity. This is believed to have compensated the effect of high formation factors on the bulk saturated layer resistivity within the affected area.  相似文献   

3.
Very low frequency electromagnetic (EM) methods using VLF transmitters have found many applications in subsurface geophysical investigations. Surface measurements involving both the vertical component of the magnetic field (VLF-EM or VLF-Z) and of the apparent resistivity (VLF-R) are increasingly common. Although extensive VLF data sets have been successfully used for mapping purposes, modelling and interpretation techniques which asess the third (i.e. depth) dimension appear limited.Given a profile of VLF-R measurements the main purpose of the present study is to demonstrate an automatic method for the construction of a resistivity cross-section. The technique used is one of a new generation of regularised inversion methods. These techniques attempt to overcome the problem of equivalence/non-uniqueness in EM sounding data by constructing the resistivity distribution with the minimum amount of structure that fits the data.VLF data represent a special case of plane-wave EM sounding in that they conform, in practice, to a single-frequency technique. This fact imposes a limitation in the amount of vertical resolution that we can expect using such data. In the case of two-dimensional modelling and inversion, resolution through the cross-section is a resultant attribute from both vertical and lateral resistivity gradients within the subsurface. In order to provide insight into the practical application of regularised inversion techniques to VLF data, both synthetic and field examples are considered. Both sets of examples are primarily concerned with VLF data applied to near-surface fault mapping where the main aim is to assess the location, dip and depth extent of conductive subsurface features.  相似文献   

4.
In order to evaluate the risk associated by an earthflow to abruptly evolve into a torrential flow, the knowledge of its internal structure is necessary. Geotechnical methods are important to reach this goal. However, because of the rough topography associated with earthflows, their surface heterogeneities, and the spatial variations of the thickness of the potentially moving mass, non-intrusive geophysical methods offer a very useful tool that complements traditional geotechnical methods. We report the results of a comprehensive study covering a 150 m by 200 m area of the Super Sauze earthflow. This earthflow developed in black marls in the southern French Alps. Shallow electrical conductivity investigations, derived using low frequency domain electromagnetics, maps hidden gullies and crests and lateral variations of the clay and the water content within the first 5 m below the ground surface. Electrical resistivity tomography allows to extrapolate this information down to 10 m below the ground surface along selected transects. The vertical structure of the earthflow, down to the substratum, is defined precisely thanks to joint inversion of DC and TDEM vertical soundings along one profile: the flowing upper layer and the position of the substratum are clearly evidenced. Combining this geophysical datasets with geotechnical tests and drill holes, we provide an estimate of both the location and the volume of the potentially most dangerous areas of the earthflow.  相似文献   

5.
This paper presents the results of the application of the Ground Penetrating Radar (GPR) method, or Georadar, in outlining a zone of contamination due to solid residues at the waste burial site of Rio Claro in the state of São Paulo, SE Brazil. A total of eight GPR profiles with 50- and 100-MHz antennae were surveyed. Six profiles were located within the landfill site and the remaining two were outside. The main objective of the GPR survey was to evaluate the side extension of contamination. A Vertical Electric Sounding (VES) survey was performed at four points within the site in order to investigate the vertical extent of the contamination plume and to define the bottom of the landfill. Two additional VESs were done outside the landfill with the purpose of determining the top of the ground water table and the geoelectric stratigraphy of the background. From the interpretation of the GPR profiles, it was possible to locate the top of the contamination plume and to infer that it was migrating laterally beyond the limits of the waste disposal site. This was observed along the profile situated close to the highway SP-127, which was about 20 m from the limit of the site. The signature of the contaminant appears as a discontinuous reflector that is believed to be a shallow ground water table. The discontinuity is marked by a shadow zone, which is characteristic of conductive contaminant residues. The contamination did not move far enough to reach a sugar cane plantation located at approximately 100 m from the border of the site. In the regions free from contamination, the ground water table was mapped at approximately 10 m of depth, and it was characterized by a strong and continuous reflector. The radar signal penetrated deep enough and enabled the identification of a second reflector at approximately 14 m deep, interpreted as the contact between the Rio Claro and the Corumbataí formations. The contact is marked by the presence of gravel characterized by ferruginous concretes, which cause the strong amplitude reflection in the GPR profile. Within the landfill site, the quantitative interpretation of the VES results showed the contamination zone. The base of the landfill varies between 11 and 15 m deep. Outside the landfill site, the VES results showed no indication of contamination and allowed the determination of the top of the ground water table and the contact between the Rio Claro and the Corumbataí formations. The results of GPR and VES showed a good agreement and the integrated interpretations were supported by local geology and information from several boreholes, about 17 m depth, on average. The bottom of the landfill reaches a maximum of 14.5 m depth.  相似文献   

6.
Salt water intrusion models are commonly used to support groundwater resource management in coastal aquifers. Concentration data used for model calibration are often sparse and limited in spatial extent. With airborne and ground‐based electromagnetic surveys, electrical resistivity models can be obtained to provide high‐resolution three‐dimensional models of subsurface resistivity variations that can be related to geology and salt concentrations on a regional scale. Several previous studies have calibrated salt water intrusion models with geophysical data, but are typically limited to the use of the inverted electrical resistivity models without considering the measured geophysical data directly. This induces a number of errors related to inconsistent scales between the geophysical and hydrologic models and the applied regularization constraints in the geophysical inversion. To overcome these errors, we perform a coupled hydrogeophysical inversion (CHI) in which we use a salt water intrusion model to interpret the geophysical data and guide the geophysical inversion. We refer to this methodology as a Coupled Hydrogeophysical Inversion‐State (CHI‐S), in which simulated salt concentrations are transformed to an electrical resistivity model, after which a geophysical forward response is calculated and compared with the measured geophysical data. This approach was applied for a field site in Santa Cruz County, California, where a time‐domain electromagnetic (TDEM) dataset was collected. For this location, a simple two‐dimensional cross‐sectional salt water intrusion model was developed, for which we estimated five uniform aquifer properties, incorporating the porosity that was also part of the employed petrophysical relationship. In addition, one geophysical parameter was estimated. The six parameters could be resolved well by fitting more than 300 apparent resistivities that were comprised by the TDEM dataset. Except for three sounding locations, all the TDEM data could be fitted close to a root‐mean‐square error of 1. Possible explanations for the poor fit of these soundings are the assumption of spatial uniformity, fixed boundary conditions and the neglecting of 3D effects in the groundwater model and the TDEM forward responses.  相似文献   

7.
Furness , P. 1993. Gradient Array Profiles over thin resistive veins. Geophysical Prospecting 41 , 113–130. Gradient array geoelectric surveys are commonly used to explore for buried sheet-like targets. It is demonstrated that under certain circumstances the responses of such features can become practically equivalent for a range of models differing considerably in resistivity and thickness. This is the dual of the familiar equivalence phenomenon associated with thin beds in geoelectric sounding operations. Hence the geoelectric response profiles over thin dipping resistive veins are conveniently studied by considering equivalent forms with vanishing thickness and infinite resistivity but with the same resistivity-thickness product. The effects of varying the dip, depth of burial, depth extent and resistivity–thickness product of such features on the gradient array response profiles are investigated by means of a series of numerical experiments. These demonstrate several effects of significance to survey design and data interpretation. In particular it is found that while the resistivity–thickness product influences the amplitude of the response profiles it has little effect on their form. A similar behaviour is found to be exhibited by veins with extended depth extent when the dip is varied. A complete quantitative interpretation of gradient array profiles over thin dipping resistive veins is thus only possible for veins of limited depth extent. For veins with an extended depth dimension, the data is ambiguous (in a practical sense) in terms of the dip and the resistivity–thickness product. Here, the interpretation can only be expected to deduce the horizontal and vertical locations of the vein apex.  相似文献   

8.
The interpretation of vertical electrical sounding data can be facilitated by the application of the reciprocal geoelectric section. If an apparent resistivity field curve has a descending right end, the apparent resistivity curve of the reciprocal geoelectric section can be obtained by the application of linear filter theory; from this the total transverse resistance of the geoelectric section can be calculated without having to interpret the field curve. In addition, Orellana's auxiliary point method can now be extended to interpret three and four layer apparent resistivity curves of all types. This paper summarizes the properties of the resistivity transform curve, the apparent resistivity curve, and the apparent resistivity curve of the reciprocal geoelectric section, with several new applications.  相似文献   

9.
A 3D electrical resistivity imaging survey is presented in this paper. The objective was to investigate an underground wastewater system at the University of Malaya, Malaysia. Apparent resistivity data were collected along ten parallel lines using a Wenner-Schlumberger configuration; electrode cables were oriented in the x-direction with 3 m spacing. Roll-along measurements using a line spacing of 3 m were carried out covering a grid of 20 × 10 electrodes. All data sets were merged into a single data file in order to perform a 3D inversion. Two different 3D least squares algorithms, based on the robust inversion method and the smoothness-constrained technique, were used for the inversion of the apparent resistivity data. Both the horizontal and vertical extents of the anomalous zones found by inversion are displayed. The results indicate the superiority of the robust inversion method over the smoothness-constrained technique at this site. The results are in sufficient accordance with previously known information about the investigation area. The results show that 3D electrical resistivity imaging surveys, in combination with an appropriate 3D inversion method, can be highly useful for engineering and archaeological investigations as well as for environmental applications.  相似文献   

10.
Airborne VLF data are routinely collected by The Geological Survey of Sweden (SGU) as part of its bedrock mapping programme. In this paper we demonstrate that the novel Tensor VLF technique developed at Uppsala University and SGU can provide useful qualitative and quantitative information about the electrical conductivity distribution in the upper few hundred meters. Single transmitter scalar VLF maps emphasize those conductive structures that have dominant strikes in the direction of the transmitter. The tensor tipper (essentially the vertical magnetic field from currents along the strike direction) calculated from multiple transmitters is dependent only upon the underlying conductivity structure. Transformation of the tipper into the peaker (the horizontal divergence) has proven to enhance the lateral resolution while the transformation to the apparent resistivity can be used to discriminate different rock types. Two case histories from the application of VLF data are presented in this study. Two dimensional structures can be quantitatively modelled by modern inversion methods developed originally for deep electromagnetic MT soundings. Direct inversion of the real and imaginary parts of the tipper provides more quantitative information about the subsurface resistivity distribution.  相似文献   

11.
In the central part of the Bolivian Altiplano, the shallow groundwater presents electrical conductivities ranging from 0·1 to 20 mS/cm. In order to study the origin of this salinity pattern, a good knowledge is required of the geometry of the aquifer at depth. In this study, geophysics has been used to complement the sparse data available from drill holes. One hundred time‐domain electromagnetic (TDEM) soundings were carried out over an area of 1750 km2. About 20 geological logs were available close to some of the TDEM soundings. Three intermediate results were obtained from the combined data: (i) the relationship between the electrical conductivity of the groundwater and the formation resistivity, (ii) geoelectrical cross‐sections and (iii) geoelectrical maps at various depths. The limited data set shows a relationship between resistivity and the nature of the rock. From the cross‐sections, a conductive substratum with a resistivity of less than 1 Ω·m was identified at most of the sites at depths ranging from 50 to 350 m. This substratum could be a clay‐rich formation containing brines. Using derived relationships, maps of the nature of the formation (sandy, intermediate and clayey sediments) were established at depths of 10 and 50 m. Discrimination between sand and clays was impossible where groundwater conductivity is high (>3 mS/cm). In the central part of the area, where the groundwater conductivity is low, sandy sediments are likely to be present from the surface to a depth of more than 200 m. Clayey sediments are more likely to be present in the south‐east and probably constitute a hydraulic barrier to groundwater flow. In conclusion, the study demonstrates the efficiency of the TDEM sounding method to map conductive zones. Copyright © 2001 John Wiley & Sons, Ltd.  相似文献   

12.
Geophysical investigations using conventional techniques applied to groundwater exploration can often present strong limitations involving high financial costs, complex acquisition logistics and high ambiguity in results. Dispersion of the electric current flow, induced polarization) effects, cultural noises and shallow lateral heterogeneities represent the main problems faced by geoelectric methods in these types of surveys. Moreover, elements such as intrusions and mineralization at different depths may be responsible for signal attenuation as well as high resistivity in unsaturated zones and complex three-dimensional formations or clayey zones cause variations in the electric current. The focused source electromagnetic and differentially normalized method approaches can help to solve some these issues. Aiming at a higher signal-to-noise ratio, the focused source electromagnetic method and approaches of the differentially normalized method, first applied to petroleum exploration, are tested on a groundwater target, in a karst environment sectioned by a diabase dyke. We performed the processing and analysis on real IP resistivity profiling data acquired with two-way dipole-dipole array, guided by magnetic data acquired on the same profile, mapping a diabase dyke. The inversion of focused source electromagnetic method/differentially normalized method was not performed, instead that we converted the induced polarization–resistivity data to a differential signal to qualitatively prove the presence of aquifer. Joint interpretation of focused source electromagnetic method curves and inverted two-dimensional induced polarization–resistivity sections allowed for precise delineation of a conductive zone associated with the karst aquifer, le magnetics allowed for the definition of a neighbour dyke. The techniques have great potential in the aid of groundwater exploration, contributing substantially to the reduction of interpretation ambiguity. Focused source electromagnetic method/differentially normalized method/ approaches show that a simple linear combination of the conventional geoelectric data is able to remove the geological noise and provide the vertical focusing of the electric current.  相似文献   

13.
The Nuclear Magnetic Resonance (NMR) method is the only physical tool currently available which is able to detect directly the presence of fresh water in the subsurface. The Time Domain Electromagnetic (TDEM) method, in turn, has been proven highly efficient in detecting saline groundwater. The combined application of these two methods is the most promising way to delineate accurately groundwater-bearing aquifers and to evaluate the quality of the water. This idea was tested during the feasibility study carried out under different hydrogeological conditions throughout Israel during August–September 1992. The Russian Hydroscope and Geonics PROTEM-IV instruments were used for the NMR and TDEM measurements, respectively.A total of 36 NMR and 12 TDEM stations was established, mostly in close proximity to existing observation wells. Among these only 19 NMR measurements showed reasonable signal-to-noise characteristics, while the rest were obviously distorted by ambient noise. The number of distorted measurements could have been even greater had they been carried out at all points planned. However, a significant number of the NMR stations were cancelled due to their proximity (less than 1–1.5 km) to electric power lines. As a result almost the entire Mediterranean coast of Israel, which was originally chosen as the main test site for this survey, turned out to be unsuitable owing to the low ambient noise protection of the Hydroscope. Another serious limitation of NMR measurements is the maximum penetration depth. The deepest information obtained during the feasibility study was from a depth of 74 m.Nevertheless, within the framework of its applicability, the NMR measurements proved to be sufficiently accurate and to have a high resolving capability. A comparison with the borehole data shows that, in most cases, NMR is able not only to detect the presence of water, but also to delineate different subaquifers. At the same time, however, the transmissivity and aquifer texture are much less reliably detected. The combined application of the NMR and TDEM methods may essentially improve the reliability of the interpretation. In all cases where the NMR anomaly fits the drop in TDEM resistivity, water of a different salinity is found at approximately the same depth. A reasonable correlation between the interpreted resistivities and water salinities is obtained for these horizons. However, if only one method indicates the presence of water, this, in many cases, was not confirmed by the borehole data. The TDEM anomalies were obviously caused by low-resistivity lithologies, while some of the false NMR signals could be explained by a low signal-to-noise ratio.As regards the freshwater/seawater interface, this was, in all cases, accurately detected by the TDEM measurements alone. It is interesting to note that at the same depth, NMR measurements indicated a drastically increasing anomaly followed by the absence of water at greater depths. The latter can most likely be explained by the very low resistivity of the sea water, which is not taken into account by the existing NMR interpretation.  相似文献   

14.
Geophysical monitoring and evaluation of coastal plain aquifers   总被引:1,自引:0,他引:1  
We use time domain electromagnetic (TDEM) soundings to monitor ground water conditions beneath the coastal plain in eastern North Carolina. The TDEM method measures the earth's response to an induced electromagnetic field. The resulting signal is converted, through a complex inversion process, to apparent resistivity values, which can be directly correlated to borehole resistivity logs. TDEM soundings are used to map the interface between fresh and salt water within coastal aquifers, and estimate depth to basement when siting new monitoring wells. Focused TDEM surveys have identified areas of salt water encroachment caused by high volumes of discharge from local supply wells. Electromagnetic sounding, when used in tandem with the state's network of monitoring wells, is an accurate and inexpensive tool for evaluating fresh water/salt water relationships on both local and regional scales within coastal plain aquifers.  相似文献   

15.
Transient electromagnetic (TEM), self-potential (SP) and geoelectrical mapping measurements were carried out at the Chernorud-Mukhor site in the Priolkhonje area on the western shore of the Lake Baikal. All measurements were made along several profiles across the main strike of the regional Primorsky fault. TEM measurements were carried out in a time range from a few tens of microseconds to several tens of milliseconds. The most important result of the 1D modelling of TEM soundings is the discovery of nearly horizontal boundaries that divide high resistive overlying and well conducting underlying rocks. The resistivity of the former is in the range from 100 Ωm to 1000 Ωm, while the resistivity of the latter varies from less than 1 Ωm to several tens of Ωm. This good conductive zone could also be verified by geoelectrical mapping using Schlumberger array (AB/2=100 m). Due to high conductivity of the underlying rocks only the upper boundary of the conductive layer could be determined by TEM soundings. A regional SP anomaly with amplitude of about −450 mV has also been observed above the low resistivity zone indicating the electron nature of its conductance. Geologically, the conductive zone is represented by a graphite-bearing layer within the region of archean rocks. Since that layer extends over a large area, it may be used as a key in studying structures and tectonics of the Priolkhonje area. A 1D TEM geoelectric section shows a wide, gently sloping syncline as a probable base structure of the Chernorud-Mukhor site. Neotectonic faults divide the syncline into vertically displaced blocks that form a wide complicated graben with a total amplitude of about 250 m.  相似文献   

16.
The study analyzes data from high-precision measurements of the apparent resistivity by a stationary multielectrode vertical electric sounding (VES) system including 12 current and 4 potential lines spaced 2–650 m apart. Observations had been being carried out at the Garm test area on a daily basis for 12 years in an earthquake prediction experiment. The use of special technical methods during measurements ensured an instrumental error of about 0.01%. The virtual error of each individual measurement of apparent resistivity (taking into account all possible noise) was 0.1–0.2%. The availability of more than 3000 VES curves measured in different seasons allows us to propose a new approach to constructing a geoelectric section model. To solve the inverse VES problem, a set of 36 averaged 10-day VES curves was analyzed, each of which was obtained by averaging approximately 100 individual VES curves accumulated in the same 10-day period of the annual (seasonal) cycle in different years. Comparative analysis of these curves made it possible to calculate and include corrections for stationary geological noise in the model. As a result, it was possible to substantially reduce (by an order of magnitude) the discrepancies in fitting the curves and dramatically narrow the equivalence domain. Based on the results of our analysis, we have constructed a model of a four-layer horizontally layered geoelectric section of the Khazor-Chashma depression to adequately describe not only the averaged section, but also its seasonal variations throughout the year. The stability in estimating the model parameters is studied. To further reduce the equivalence domain, we propose that the layer thicknesses be fixed. This model can be used not only to study the aforementioned characteristics of the section, but also to monitor time variations of resistivity in individual layers of the section. This will significantly improve the resolving power of systems for detecting time variations in geoelectric sections, including when searching for earthquake precursors.  相似文献   

17.
A method of detecting lateral resistivity inhomogeneities with a multi-electrode cable for the Schlumberger array is presented. Using such a cable system, two dipole-dipole soundings are gathered in addition to the Schlumberger sounding at each point. Offset differences calculated from the dipole-dipole data give qualitative information about lateral resistivity inhomogeneities. Results from 1D modelling can give quantitative information about the 2D resistivity distribution since the dipole-dipole soundings are made to either side of the Schlumberger sounding point. Examples from two different locations in Norway are shown. At Reinøya, northern Norway, a dipping layer, confirmed by refraction seismic data, was identified. In a sedimentary basin with a contamination plume at Haslemoen, southern Norway, the method has revealed lateral variations in resistivity. In both cases, the Schlumberger soundings could be fitted with a 1D resistivity model.  相似文献   

18.
The aquifer of Nador has suffered significant salinization due to seawater intrusion. It was strongly exploited during the 1980s and 1990s. A piezometric analysis in April 2012 showed the piezometric level to lie at 0 m a.s.l. over the plain; as a result, this aquifer is highly sensitive to the marine intrusion with an electrical conductivity of the groundwater in of exceeds 2500 μS/cm and so there are no abstractions for irrigation or drinking purpose from these sectors. The geoelectric study also showed the lateral variation in the electrical resistivity for two moments separated in time by more than 45 years. The fall in resistivity may be due to the encroachment of seawater into previously freshwater zones and/or infiltration during the era of pumped abstractions downstream. The resistivity surveys reveal two distinct sectors: the saturated aquifer in brackish and saltwater having resistivity values to 36-10 Ωm, which extends nearly 1600 m inland.  相似文献   

19.
Three controlled experiments were conducted at the Oregon Graduate Institute (OGI) with the purpose of evaluating electrical resistance tomography for imaging underground processes associated with in-situ site assessment and remediation. The OGI facilities are unique: a double-wall tank 10 m square and 5 m deep, filled with river bottom sediments and instrumented for geophysical and hydrological studies. At this facility, liquid contaminants could be released into the confined soil at a scale sufficiently large to represent real-world physical phenomena.In the first test, images of electrical resistivity were made before and during a controlled spill of gasoline into a sandy soil. The primary purpose was to determine if electrical resistivity images could detect the hydrocarbon in either the vadose or saturated zone. Definite changes in electrical resistivity were observed in both the vadose and saturated soils. The effects were an increase in resistivity of as much as 10% above pre-release values. A single resistive anomaly was imaged, directly below the release point, principally within the vadose zone but extending below the phreatic surface. The anomaly remained identifiable in tomograms taken two days after the release ended with clear indications of lateral spreading along the water table.The second test involved electrical resistance measurements before, during, and after air sparging in a saturated soil. The primary purpose was to determine if the electrical images could be used to detect and delineate the extent of the zone influenced by sparging. The images showed an increase of about 20% in resistivity over background values within the sparged zone and the extent of the imaged zone agreed with that inferred from other information.Electrical resistivity tomography measurements were made under a simulated oil storage tank in the third test. Comparison of images taken before and during separate releases of brine and water showed effects of changes induced by the water or brine. The simulated leak and its location were imaged as a conductive anomaly centered near the point of origin and were observed to spread with time during the release.  相似文献   

20.
根据中国地震局电磁学科技术管理组制定的《地电台站观测效能评估方案》,对新沂台地电阻率新场地观测效能进行了全面评价。从评价结果来看,新沂地震台地电阻率新场地远离或避开蔬菜大棚,有效地避免了蔬菜大棚的影响,台址结构条件、电磁环境、台站观测系统等均符合地电阻率台站建设规范要求,地电阻率观测精度符合异常识别的指标要求。新场地在2013年的试运行中能够记录到十分清晰的区域应力场调整,随着时间的推移,其观测数据对本区及邻近地区的地震监测、预报和地震科学研究将发挥更加重要的作用。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号