首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 641 毫秒
1.
Waters co‐produced during petroleum extraction are the largest waste streams from oil and gas development. Reuse or disposal of these waters is difficult due to their high salinities and the sheer volumes generated. Produced waters (PWs) may also contain valuable mineral commodities. While an understanding of produced water trace element composition is required for evaluating the associated resource and waste potential of these materials, measuring trace elements in brines is challenging due to the dilution requirements of typical methods. Alternatively, inductively coupled plasma‐optical emission spectrometry (ICP‐OES) has shown promise as being capable of direct measurements of trace elements within PWs with minimal dilution. Here, we evaluate direct ICP‐OES trace element quantification in PWs for seventeen trace elements (As, Al, Ba, Be, Cd, Cr, Co, Cu, Hg, Mo, Ni, Pb, Rb, Sb, U, V and Zn) within fifteen PWs from five U.S. continuous reservoirs. The total analytical uncertainties associated with the trace element levels determined using ICP‐OES were estimated to be better than ± 30% (2s) except for Rb, which could not be determined due to ionisation interferences. The ICP‐OES results are compared with trace element levels determined using inductively coupled plasma‐mass spectrometry from the same samples. Our results demonstrate the potential for direct analysis of high‐salinity waters using ICP‐OES with minimal dilution and provide trace element concentrations in waters from several important U.S. petroleum‐generating reservoirs where available data are sparse.  相似文献   

2.
To precisely determine the abundances of fifty‐two elements found within natural water samples, with mass fractions down to fg g?1 level, we have developed a method which combines freeze‐drying pre‐concentration (FDC) and isotope dilution internal standardisation (ID‐IS). By sublimation of H2O, the sample solution was reduced to < 1/50 of the original volume. To determine element abundance with accuracy better than 10%, we found that for solutions being analysed by mass spectrometry the HNO3 concentration should be > 0.3 mol l?1 to avoid hydrolysis. Matrix‐affected signal suppression was not significant for the solutions with NaCl concentrations lower than 0.2 and 0.1 cg g?1 for quadrupole ICP‐MS and sector field ICP‐MS, respectively. The recovery yields of elements after FDC were 97–105%. The detection limits for the sample solutions prepared by FDC were ≤ 10 pg g?1, except for Na, K and Ca. Blanks prepared using FDC were at pg‐levels, except for eleven elements (Na, Mg, Al, P, Ca, Mn, Fe, Co, Ni, Cu and Zn). The abundances of fifty‐two elements in bottled drinking water were determined from five different geological sources with mass fractions ranging from the fg g?1 to μg g?1 level with high accuracy.  相似文献   

3.
A method for the determination of total sulfur in geological materials by inductively coupled plasma‐optical emission spectrometry (ICP‐OES) is described. We show that good results were obtained using this method even for sample types with very low (< 20 μg g?1) sulfur concentration (e.g., peridotite). Sulfur was determined in fifteen geological reference materials with different sulfur contents. For reference materials with certified sulfur contents, the ICP‐OES method gave results in excellent agreement with certified values, and uncertainties better than 4% RSD. ICP‐OES results for sulfur in other reference materials yielded RSDs better than 10%, where S concentrations were > 100 μg g?1 (except for diabase W‐2a, 16% RSD). Reference materials with lower sulfur contents (< 40 μg g?1) showed much higher RSDs (17–18%). Except for RMs with certified values for sulfur, most data obtained by the combustion infrared detection method generally showed higher concentrations than those measured by ICP‐OES and a better RSD (≤ 8% for all materials except DTS‐2b).  相似文献   

4.
In both nature and synthetic experiments, the common iron oxide haematite (α‐Fe2O3) can incorporate significant amounts of U into its crystal structure and retain radiogenic Pb over geological time. Haematite is a ubiquitous component of many ore deposit types and, therefore, represents a valuable hydrothermal mineral geochronometer, allowing direct constraints to be placed on the timing of ore formation and upgrading. However, to date, no suitable natural haematite reference material has been identified. Here, a synthetic haematite U‐Pb reference material (MR‐HFO) is characterised using LA‐ICP‐MS and ID‐TIMS. Centimetre‐scale ‘chips’ of synthesised α‐Fe2O3 were randomly microsampled via laser ablation‐extraction and analysed using ID‐TIMS. Reproducible U/Pb and Pb/Pb measurements were obtained across four separate chips (n = 13). Subsequently, an evaluation of the suitability MR‐HFO in constraining U‐Pb data via LA‐ICP‐MS is presented using a selection of natural samples ranging from Cenozoic to Proterozoic in age. The MR‐HFO normalised U‐Pb ratios are more concordant and ages more accurate versus the same LA‐ICP‐MS spot analyses normalised to zircon reference material, when compared with independently acquired ID‐TIMS data from the same natural haematite grains. Results establish MR‐HFO as a suitable reference material for LA‐ICP‐MS haematite U‐Pb geochronology.  相似文献   

5.
This paper reviews research on coprolites from India, providing the first evidence of microcoprolites from the early Miocene (Aquitanian) Khari Nadi Formation sedimentary succession, exposed about 1.5 km northeast of the village of Kotada, Kachchh (Kutch) District, Gujarat State, western India. Morphometric and size comparisons (in a statistical framework) with known coprolites from the Mesozoic-Cenozoic successions of India (including those recorded herein) and globally suggest that fishes were the likely producers of the Kotada coprolites. Scanning electron microscopy confirms the presence of fish dental remains within the coprolites, while both Scanning Electron Microscopy (SEM) and Energy Dispersive X-ray Spectroscopy (EDS) reveal the phosphatic nature of the microscopic coprolite specimens (recorded herein) hinting that the producer(s) were predominantly carnivorous (ichthyophagous) in their diet. Furthermore, X-Ray Fluorescence (XRF) analysis of the host and associated lithologies allows us to deduce that the Kotada coprolites were deposited in a shallow marine environment, with possible aerial exposure of the host lithology occurring at some point after deposition. To the best of our knowledge, the present report is the first record of microscopic fish coprolites from India, as well as being the first from the Aquitanian of India and the oldest Neogene record from India.  相似文献   

6.
Three synthetic reference glasses were prepared by directly fusing and stirring 3.8 kg of high‐purity oxide powders to provide reference materials for microanalytical work. These glasses have andesitic major compositions and are doped with fifty‐four trace elements in nearly identical abundance (500, 50, 5 µg g?1) using oxide powders or element solutions, and are named ARM‐1, 2 and 3, respectively. We further document that sector‐field (SF) ICP‐MS (Element 2 or Element XR) is capable of sweeping seventy‐seven isotopes (from 7Li to 238U, a total of sixty‐eight elements) in 1 s and, thus, is able to quantify up to sixty‐eight elements by laser sampling. Micro‐ and bulk analyses indicate that the glasses are homogeneous with respect to major and trace elements. This paper provides preliminary data for the ARM glasses using a variety of analytical techniques (EPMA, XRF, ICP‐OES, ICP‐MS, LA‐Q‐ICP‐MS and LA‐SF‐ICP‐MS) performed in ten laboratories. Discrepancies in the data of V, Cr, Ni and Tl exist, mainly caused by analytical limitations. Preliminary reference and information values for fifty‐six elements were calculated with uncertainties [2 relative standard error (RSE)] estimated in the range of 1–20%.  相似文献   

7.
Rare earth elements (REEs) are very important to technological development as well as to geochemical and environmental studies. In this work, hydrofluoric acid (HF) was replaced by condensed phosphoric acid (CPA) in the digestion of geological samples, and the quantification of REEs was performed by inductively coupled plasma‐optical emission spectrometry (ICP‐OES). Six international reference materials (RMs), named DC86318, CGL 111, CGL 124, CGL 126, OKA‐2 and COQ‐1 and three Brazilian ore samples, named Araxá, Catalão and Pitinga were analysed. Only zircon and xenotime, which are potential REE‐bearing minerals, were not completely dissolved. Nevertheless, no REE associated with zircon was detected. The investigated digestion method presented many advantages: It was relatively fast (3 h), avoided fluoride precipitation, it was less hazardous because handling diluted H3PO4 is safer than HF, NH4F or NH4HF2 aqueous solutions, it preserved the quartz fittings of the measurement equipment and the final solution contained lower levels of total dissolved solids than those produced by the fusion method.  相似文献   

8.
An innovative approach of double pulse laser‐induced breakdown spectroscopy (DP‐LIBS) coupled with optical microscopy was applied to the characterisation and quantitative analysis of the Agoudal iron meteorite in bulk sample and in petrographic thin section. Qualitative analysis identified the elements Ca, Co, Fe, Ga, Li and Ni in the thin section and the whole meteorite. Two different methods, calibration‐free LIBS and one‐point calibration LIBS, were used as complementary methodologies for quantitative LIBS analysis. The elemental composition data obtained by LIBS were in good agreement with the compositional analyses obtained by traditional methods generally applied for the analysis of meteorites, such as ICP‐MS and EDS‐SEM. Besides the recognised advantages of LIBS over traditional techniques, including versatility, minimal destructivity, lack of waste production, low operating costs, rapidity of analysis, availability of transportable or portable systems, etc., additional advantages of this technique in the analysis of meteorites are precision and accuracy, sensitivity to low atomic number elements such as Li and the capacity to detect and quantify Co contents that cannot be obtained by EDS‐SEM.  相似文献   

9.
A new olivine reference material – MongOL Sh11‐2 – for in situ analysis has been prepared from the central portion of a large (20 × 20 × 10 cm) mantle peridotite xenolith from a ~ 0.5 My old basaltic breccia at Shavaryn‐Tsaram, Tariat region, central Mongolia. The xenolith is a fertile mantle lherzolite with minimal signs of alteration. Approximately 10 g of 0.5–2 mm gem quality olivine fragments were separated under binocular microscope and analysed by EPMA, LA‐ICP‐MS, SIMS and bulk analytical methods (ID‐ICP‐MS for Mg and Fe, XRF, ICP‐MS) for major, minor and trace elements at six institutions world‐wide. The results show that the olivine fragments are sufficiently homogeneous with respect to major (Mg, Fe, Si), minor and trace elements. Significant inhomogeneity was revealed only for phosphorus (homogeneity index of 12.4), whereas Li, Na, Al, Sc, Ti and Cr show minor inhomogeneity (homogeneity index of 1–2). The presence of some mineral and fluid‐melt micro‐inclusions may be responsible for the inconsistency in mass fractions obtained by in situ and bulk analytical methods for Al, Cu, Sr, Zr, Ga, Dy and Ho. Here we report reference and information values for twenty‐seven major, minor and trace elements.  相似文献   

10.
The accurate and precise determination of Li isotopic composition by MC‐ICP‐MS suffers from the poor performance of traditional column chromatography. Previously established chromatographic processes cannot completely remove Na in complex geological samples, which is currently interpreted to be a result of Na breakthrough. In this study, Na breakthrough during single‐column purification was found to differ between simply artificial Na‐containing sample solutions, where a little Na residue was found, and silicate rocks, where a large amount of breakthrough occurred. A revised two‐step column purification for Li using 0.5 and 0.3 mol l?1 HCl as eluents was designed to remove the Na. This modified method achieves high‐efficiency Li purification from Na and consequently avoiding high Na/Li ratio interference for subsequent MC‐ICP‐MS analyses. The proposed method was validated by the analysis of a series of reference materials, including Li2CO3 (IRMM‐016, ‐0.10‰), basalt (BCR‐2: 2.68‰; BHVO‐2: 4.39‰), andesite (AGV‐2: 6.46‰; RGM‐2: 2.59‰), granodiorite (GSP‐2: ?0.87‰) and seawater (CASS‐5, 30.88‰). This work reports early Na appearance prior to the elution curves in chromatography and emphasises its influence for subsequent Li isotope measurement. Based on the findings, the established two‐step method would be more secure than single‐column chemistry for Li purification.  相似文献   

11.
Coprolites from the Beechy Member of the Cretaceous Bearpaw Formation, southern Saskatchewan, presumably deposited by one or more species of mosasaur or large fish/shark, were recovered and analyzed using SEM/EDS. The data reveal the presence of pseudomorphous coccoid bacteria, potential filamentous bacteria, bacterial endospores and filamentous fungi. No recorded fossil plant or bone material could be identified, either within the highly compressed coprolitic mat-flattened full coprolite bolus – of recovered marine sediment encased in a mixed mat of hematite–apatite primary minerals heavily coated with Ca-smectite and nontronite, or the full coprolite bolus. The presence of fossil bacteria with morphological characteristics similar to those of endospores in other environments suggests that only robust microbial forms such as these survive diagenesis, partly with some carbon still intact, the remainder replaced with silica and iron. The data support the view that coprolites can serve as a useful source of information on the ancient microbial world.  相似文献   

12.
Sphalerite (ZnS) is an abundant ore mineral and an important carrier of elements such as Ge, Ga and In used in high‐technology applications. In situ measurements of trace elements in natural sphalerite samples using LA‐ICP‐MS are hampered by a lack of homogenous matrix‐matched sulfide reference materials available for calibration. The preparation of the MUL‐ZnS1 calibration material containing the trace elements V, Cr, Mn, Co, Ni, Cu, Ga, Ge, As, Se, Mo, Ag, Cd, In, Sn, Sb, Tl and Pb besides Zn, Fe and S is reported. Commercially available ZnS, FeS, CdS products were used as the major components, whereas the trace elements were added by doping with single‐element ICP‐MS standard solutions and natural mineral powders. The resulting powder mixture was pressed to pellets and sintered at 400 °C for 100 h using argon as an inert gas. To confirm the homogeneity of major and trace element distributions within the MUL‐ZnS1 calibration material, measurements were performed using EPMA, solution ICP‐MS, ICP‐OES and LA‐ICP‐MS. The results show that MUL‐ZnS‐1 is an appropriate material for calibrating trace element determination in sphalerite using LA‐ICP‐MS.  相似文献   

13.
An efficient, clean procedure for the measurement of element mass fractions in bulk rock nanoparticulate pressed powder pellets (PPPs) by 193 nm laser ablation ICP‐MS is presented. Samples were pulverised by wet milling and pelletised with microcrystalline cellulose as a binder, allowing non‐cohesive materials such as quartz or ceramics to be processed. The LA‐ICP‐MS PPP analytical procedure was optimised and evaluated using six different geological reference materials (JP‐1, UB‐N, BCR‐2, GSP‐2, OKUM and MUH‐1), with rigorous procedural blank quantification employing synthetic quartz. Measurement trueness of the procedure was equivalent to that achieved by solution ICP‐MS and LA‐ICP‐MS analysis of glass. The measurement repeatability was as low as 0.5–2% (1s,= 6) and, accordingly, PPP homogeneity could be demonstrated. Calibration based on the reference glasses NIST SRM 610, NIST SRM 612, BCR‐2G and GSD‐1G revealed matrix effects for glass and PPP measurement with NIST SRM 61×; using basalt glasses eliminated this problem. Most significantly, trace elements not commonly measured (flux elements Li, B; chalcophile elements As, Sb, Tl, In, Bi) could be quantified. The PPP‐LA‐ICP‐MS method overcomes common problems and limitations in analytical geochemistry and thus represents an efficient and accurate alternative for bulk rock analysis.  相似文献   

14.
Laser‐induced breakdown spectroscopy (LIBS) records light emitted from the decay of electrons to lower‐energy orbitals during cooling of laser‐induced ablation plasmas; the resultant spectra can be used in a variety of geoanalytical applications. Four aspects of LIBS analysis distinguish LIBS from traditional laboratory‐based analytical techniques: (i) the lack of necessary sample preparation, allowing rapid analysis of many samples, (ii) the ability to analyse both 20 to 100 μm‐diameter spots and whole rocks, (iii) the detailed chemical signature contained in a LIBS spectrum and (iv) the ability to take LIBS into the field in backpack portable instrumentation. Three case studies illustrate potential applications of LIBS in the geosciences. First, analysis of the Carrizozo basalt flow in New Mexico, USA, illustrated that LIBS spectra could discriminate between samples of similar composition within uncertainties typical of whole‐rock analysis by X‐ray fluorescence spectrometry. Second, spectra from four sets of rubies from Madagascar and Tanzania illustrate the use of LIBS and multivariate analysis to determine provenance with success rates of > 95%. This technique can also be applied to correlation of units. Finally, a chemical map of a copper ore from Butte, MT, USA, illustrates the use of spatially defined LIBS spectra to understand chemical variations within textural context.  相似文献   

15.
The in situ measurement of Sr isotopes in carbonates by MC‐ICP‐MS is limited by the availability of suitable microanalytical reference materials (RMs), which match the samples of interest. Whereas several well‐characterised carbonate reference materials for Sr mass fractions > 1000 µg g?1 are available, there is a lack of well‐characterised carbonate microanalytical RMs with lower Sr mass fractions. Here, we present a new synthetic carbonate nanopowder RM with a Sr mass fraction of ca. 500 µg g?1 suitable for microanalytical Sr isotope research (‘NanoSr’). NanoSr was analysed by both solution‐based and in situ techniques. Element mass fractions were determined using EPMA (Ca mass fraction), as well as laser ablation and solution ICP‐MS in different laboratories. The 87Sr/86Sr ratio was determined by well‐established bulk methods for Sr isotope measurements and is 0.70756 ± 0.00003 (2s). The Sr isotope microhomogeneity of the material was determined by LA‐MC‐ICP‐MS, which resulted in 87Sr/86Sr ratios of 0.70753 ± 0.00007 (2s) and 0.70757 ± 0.00006 (2s), respectively, in agreement with the solution data within uncertainties. Thus, this new reference material is well suited to monitor and correct microanalytical Sr isotope measurements of low‐Sr, low‐REE carbonate samples. NanoSr is available from the corresponding author.  相似文献   

16.
Trace element concentrations in gold grains from various geological units in South Africa were measured in situ by field emission‐electron probe microanalysis (FE‐EPMA), laser ablation‐inductively coupled plasma‐mass spectrometry (LA‐ICP‐MS) and synchrotron micro X‐ray fluorescence spectroscopy (SR‐μ‐XRF). This study assesses the accuracy, precision and detection limits of these mostly non‐destructive analytical methods using certified reference materials and discusses their application in natural sample measurement. FE‐EPMA point analyses yielded reproducible and discernible concentrations for Au and trace concentrations of S, Cu, Ti, Hg, Fe and Ni, with detection limits well below the actual concentrations in the gold. LA‐ICP‐MS analyses required larger gold particles (> 60 μm) to avoid contamination during measurement. Elements that measured above detection limits included Ag, Cu, Ti, Fe, Pt, Pd, Mn, Cr, Ni, Sn, Hg, Pb, As and Te, which can be used for geochemical characterisation and gold fingerprinting. Although LA‐ICP‐MS measurements had lower detection limits, precision was lower than FE‐EPMA and SR‐μ‐XRF. The higher variability in absolute values measured by LA‐ICP‐MS, possibly due to micro‐inclusions, had to be critically assessed. Non‐destructive point analyses of gold alloys by SR‐μ‐XRF revealed Ag, Fe, Cu, Ni, Pb, Ti, Sb, U, Cr, Co, As, Y and Zr in the various gold samples. Detection limits were mostly lower than those for elements measured by FE‐EPMA, but higher than those for elements measured by LA‐ICP‐MS.  相似文献   

17.
Apatite incorporates variable and significant amounts of halogens (mainly F and Cl) in its crystal structure, which can be used to determine the initial F and Cl concentrations of magmas. The amount of chlorine in the apatite lattice also exerts an important compositional control on the degree of fission‐track annealing. Chlorine measurements in apatite have conventionally required electron probe microanalysis (EPMA). Laser ablation inductively coupled plasma‐mass spectrometry (LA‐ICP‐MS) is increasingly used in apatite fission‐track dating to determine U concentrations and also in simultaneous U‐Pb dating and trace element measurements of apatite. Apatite Cl measurements by ICP‐MS would remove the need for EPMA but the high (12.97 eV) first ionisation potential makes analysis challenging. Apatite Cl data were acquired using two analytical set‐ups: a Resonetics M‐50 193 nm ArF Excimer laser coupled to an Agilent 7700× quadrupole ICP‐MS (using a 26 μm spot with an 8 Hz repetition rate) and a Photon Machines Analyte Excite 193 nm ArF Excimer laser coupled to a Thermo Scientific iCAP Qc (using a 30 μm spot with a 4 Hz repetition rate). Chlorine concentrations were determined by LA‐ICP‐MS (1140 analyses in total) for nineteen apatite occurrences, and there is a comprehensive EPMA Cl and F data set for 13 of the apatite samples. The apatite sample suite includes different compositions representative of the range likely to be encountered in natural apatites, along with extreme variants including two end‐member chlorapatites. Between twenty‐six and thirty‐nine isotopes were determined in each apatite sample corresponding to a typical analytical protocol for integrated apatite fission track (U and Cl contents) and U‐Pb dating, along with REE and trace element measurements. 35Cl backgrounds (present mainly in the argon gas) were ~ 45–65 kcps in the first set‐up and ~ 4 kcps in the second set‐up. 35Cl background‐corrected signals ranged from ~ 0 cps in end‐member fluorapatite to up to ~ 90 kcps in end‐member chlorapatite. Use of a collision cell in both analytical set‐ups decreased the low mass sensitivity by approximately an order of magnitude without improving the 35Cl signal‐to‐background ratio. A minor Ca isotope was used as the internal standard to correct for drift in instrument sensitivity and variations in ablation volume during sessions. The 35Cl/43Ca values for each apatite (10–20 analyses each) when plotted against the EPMA Cl concentrations yield excellently constrained calibration relationships, demonstrating the suitability of the analytical protocol and that routine apatite Cl measurements by ICP‐MS are achievable.  相似文献   

18.
陈孟莪  陈忆元 《地质科学》1980,15(4):406-407
无论脊椎动物或无脊椎动物的粪化石在新生代沉积中均是常见的,其中椭圆形的粪球粒构成了碳酸盐沉积的重要组分。尹赞勋在更老的地层中曾记述过。  相似文献   

19.
Zircon crystals in the age range of ca. 10–300 ka can be dated by 230Th/238U (U‐Th) disequilibrium methods because of the strong fractionation between Th and U during crystallisation of zircon from melts. Laser ablation inductively coupled plasma‐mass spectrometry (LA‐ICP‐MS) analysis of nine commonly used reference zircons (at secular equilibrium) and a synthetic zircon indicates that corrections for abundance sensitivity and dizirconium trioxide molecular ions (Zr2O3+) are critical for reliable determination of 230Th abundances in zircon. When corrected for abundance sensitivity and interferences, mean activity ratios of (230Th)/(238U) for nine reference zircons analysed on five different days averaged 0.995 ± 0.023 (95% confidence weighted by data‐point uncertainty only, MSWD = 1.6; = 9), consistent with their U‐Pb ages > 4 Ma that imply equilibrium for all intermediate daughter isotopes (including 230Th) within the 238U decay chain. U‐Th zircon ages generated by LA‐ICP‐MS without mitigating (e.g., by high mass resolution) or correcting for abundance sensitivity and molecular interferences on 230Th are potentially unreliable. To validate the applicability of LA‐ICP‐MS to this dating method, we acquired data from three late Quaternary volcanic units: the 41 ka Campanian Ignimbrite (plutonic clasts), the 161 ka Kos Plateau Tuff (juvenile clasts) and the 12 ka Puy de Dôme trachyte lava (all eruption ages by Ar/Ar, with zircon U‐Th ages being of equal or slightly older). A comparison of the corrected LA‐ICP‐MS results with previously published secondary ion mass spectrometry (SIMS) data for these rocks shows comparable ages with equivalent precision for LA‐ICP‐MS and SIMS, but much shorter analysis durations (~ 2 min vs. ~ 15 min) per spot with LA‐ICP‐MS and much simpler sample preparation. Previously undated zircons from the Yali eruption (Kos‐Nisyros volcanic centre, Greece) were analysed using this method. This yielded a large age spread (~ 45 to > 300 ka), suggesting significant antecryst recycling. The youngest zircon age (~ 45 ± 10 ka) provides a reasonable maximum estimate for the eruption age, in agreement with the previously published age using oxygen isotope stratigraphy (~ 31 ka).  相似文献   

20.
A natural smoky quartz crystal from Shandong province, China, was characterised by laser ablation ICP‐MS, electron probe microanalysis (EPMA) and solution ICP‐MS to determine the concentration of twenty‐four trace and ultra trace elements. Our main focus was on Ti quantification because of the increased use of this element for titanium‐in‐quartz (TitaniQ) thermobarometry. Pieces of a uniform growth zone of 9 mm thickness within the quartz crystal were analysed in four different LA‐ICP‐MS laboratories, three EPMA laboratories and one solution‐ICP‐MS laboratory. The results reveal reproducible concentrations of Ti (57 ± 4 μg g?1), Al (154 ± 15 μg g?1), Li (30 ± 2 μg g?1), Fe (2.2 ± 0.3 μg g?1), Mn (0.34 ± 0.04 μg g?1), Ge (1.7 ± 0.2 μg g?1) and Ga (0.020 ± 0.002 μg g?1) and detectable, but less reproducible, concentrations of Be, B, Na, Cu, Zr, Sn and Pb. Concentrations of K, Ca, Sr, Mo, Ag, Sb, Ba and Au were below the limits of detection of all three techniques. The uncertainties on the average concentration determinations by multiple techniques and laboratories for Ti, Al, Li, Fe, Mn, Ga and Ge are low; hence, this quartz can serve as a reference material or a secondary reference material for microanalytical applications involving the quantification of trace elements in quartz.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号