首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
An experimental investigation was conducted in order to evaluate the influence of distance from the injection point and of parameters pertinent to the cement, the suspension and the sand on the effectiveness of microfine cement grouts. Three different cement types, each at three different gradations having nominal maximum grain sizes of 100, 20 and 10 μm, were used. Grouting effectiveness was evaluated by injecting suspensions with water to cement (W/C) ratios of 1, 2 and 3, by weight, into five uniform sand fractions with different grain sizes and eight composite sands with different gradations, using a specially constructed apparatus. Unconfined compression and permeability tests were conducted on the resulting grouted sand specimens, after curing for 28 and 90 days. Microfine cement grouted sands obtained unconfined compression strength values of up to 14.9 MPa and permeability coefficients as low as 1.3 × 10?6 cm/s or by up to 5 orders of magnitude lower than those of clean sands. The W/C ratio and the bleed capacity of suspensions as well as the effective grain size and the permeability coefficient of sands are very important parameters, since they affect substantially the grouted sand properties and are correlated satisfactorily with them. The strength and permeability of grouted sands can increase, decrease or remain constant with distance from the injection point depending on the easiness of suspension penetration into the sands. The improvement of grouted sand properties with increasing distance from the injection point is consistent with the observed increase of the cement content of grouted sands.  相似文献   

2.
高围压下砂土的渗透特性试验研究   总被引:2,自引:0,他引:2  
张改玲  王雅敬 《岩土力学》2014,35(10):2748-2754
利用高压三轴渗透试验系统,对某矿区深部的粗砂和细砂进行了高围压条件下的渗透试验。研究了同一水力梯度下渗透系数与围压的关系;同一围压下渗透系数与渗透水力梯度的关系;同一水力梯度下,围压逐级加载的渗透系数与一次加载的渗透系数之间的差别。结果表明,粗砂和细砂在同一水力梯度下渗透系数均随围压的增大而逐渐减小,在同一围压下,渗透系数会随渗透水力梯度的增大而逐渐增大;同一水力梯度下,围压逐级加载下的渗透系数明显小于一次加载条件下的渗透系数。根据围压与渗透系数的关系拟合出了两种砂样渗透系数与围压关系的数学表达式。为探究高围压下渗透系数变化的原因,研究了砂样试验过程中的体积变化和试验前后的粒度成分变化。结果表明,围压的施加过程伴随着试样的体积减小,相应的孔隙度减小,渗透系数降低;高围压条件下,砂土颗粒被挤碎成细颗粒,使得砂土的细粒含量增多,孔隙度减小,导致了砂土渗透系数的降低。  相似文献   

3.
温度和模拟渗滤液作用下黏土的渗透性能   总被引:1,自引:1,他引:0       下载免费PDF全文
采用改造的GDS全自动环境岩土渗透仪,分别以自来水和模拟渗滤液为试验用水,开展不同温度和围压下黏土渗透性能试验。研究表明,当温度从20℃升高至50℃时,渗透系数增大,最大增幅为3.5倍;当围压从50kPa增大至200kPa时,渗透系数从10-6cm/s数量级减小至10-8cm/s数量级。在温度和围压一定时,模拟渗滤液作用下黏土的渗透系数略大于自来水试验结果,二者最大比值为2.8。随着温度的升高,土中吸附结合水膜变薄,且土样体积减小,在两种效应的共同作用下,固有渗透率不是定值,相应条件下50℃与20℃固有渗透率的比值在0.72~2.99之间变化。在本试验条件下,渗透系数随温度的变化主要是由水动力黏滞系数的变化引起,但是在低围压、自来水试验时理论推算渗透系数小于实测值,高围压下理论推算值大于实测值。  相似文献   

4.
Three different types of permeability tests were conducted on 23 intact and singly jointed rock specimens, which were cored from rock blocks collected from a rock cavern under construction in Singapore. The studied rock types belong to inter-bedded meta-sandstone and meta-siltstone with very low porosity and high uniaxial compressive strength. The transient pulse water flow method was employed to measure the permeability of intact meta-sandstone under a confining pressure up to 30 MPa. It showed that the magnitude order of meta-sandstone’s intrinsic permeability is about 10?18 m2. The steady-state gas flow method was used to measure the permeability of both intact meta-siltstone and meta-sandstone in a triaxial cell under different confining pressures spanning from 2.5 to 10 MPa. The measured permeability of both rock types ranged from 10?21 to 10?20 m2. The influence of a single natural joint on the permeability of both rock types was studied by using the steady-state water flow method under different confining pressures spanning from 1.25 to 5.0 MPa, including loading and unloading phases. The measured permeability of both jointed rocks ranged from 10?13 to 10?11 m2, where the permeability of jointed meta-siltstone was usually slightly lower than that of jointed meta-sandstone. The permeability of jointed rocks decreases with increasing confining pressure, which can be well fitted by an empirical power law relationship between the permeability and confining pressure or effective pressure. The permeability of partly open cracked specimens is lower than that of open cracked specimens, but it is higher than that of the specimen with a dominant vein for the meta-sandstone under the same confining pressure. The permeability of open cracked rock specimens will partially recover during the unloading confining pressure process. The equivalent crack (joint) aperture is as narrow as a magnitude order of 10?6 m (1 μm) in the rock specimens under confining pressures spanning from 1.25 to 5.0 MPa, which represent the typical ground stress conditions in the cavern. The in situ hydraulic conductivity measurements conducted in six boreholes by the injection test showed that the in situ permeability of rock mass varies between 10?18 and 10?11 m2. The lower bound of the in situ permeability is larger than that of the present laboratory-tested intact rock specimens, while the upper bound of the in situ permeability is less than that of the present laboratory-tested jointed rock specimens. The in situ permeability test results were thus compatible with our present laboratory permeability results of both intact and jointed rock specimens.  相似文献   

5.
A transient finite difference groundwater flow model has been calibrated for the Nasia sub-catchment of the White Volta Basin. This model has been validated through a stochastic parameter randomization process and used to evaluate the impacts of groundwater abstraction scenarios on resource sustainability in the basin. A total of 1500 equally likely model realizations of the same terrain based on 1500 equally likely combinations of the data of the key aquifer input parameters were calibrated and used for the scenario analysis. This was done to evaluate model non-uniqueness arising from uncertainties in the key aquifer parameters especially hydraulic conductivity and recharge by comparing the realizations and statistically determining the degree to which they differ from each other. Parameter standard deviations, computed from the calibrated data of the key parameters of hydraulic conductivity and recharge, were used as a yardstick for evaluating model non-uniqueness. All model realizations suggest horizontal hydraulic conductivity estimates in the range of 0.03–78.4 m/day, although over 70 % of the area has values in the range of 0.03–14 m/day. Low standard deviations of the horizontal hydraulic conductivity estimates from the 1500 solutions suggest that this range adequately reflects the properties of the material in the terrain. Lateral groundwater inflows and outflows appear to constitute significant components of the groundwater budgets in the terrain, although estimated direct vertical recharge from precipitation amounts to about 7 % of annual precipitation. High potential for groundwater development has been suggested in the simulations, corroborating earlier estimates of groundwater recharge. Simulation of groundwater abstraction scenarios suggests that the domain can sustain abstraction rates of up to 200 % of the current estimated abstraction rates of 12,960 m3/day under the current recharge rates. Decreasing groundwater recharge by 10 % over a 20-year period will not significantly alter the results of this abstraction scenario. However, increasing abstraction rates by 300 % over the period with decreasing recharge by 10 % will lead to drastic drawdowns in the hydraulic head over the entire terrain by up to 6 m and could cause reversals of flow in most parts of the terrain.  相似文献   

6.
An approach to establish the recharge component of managed aquifer recharge (MAR) has recently been proposed that uses small-diameter shallow wells installed using relatively inexpensive drilling methods such as direct push. As part of further development of that approach, a generalized procedure is presented for a technical and economic assessment of the approach’s potential in comparison to other systems. Following this procedure, the use of small-diameter wells was evaluated both experimentally and numerically for a site located in southern Styria, Austria. MAR is currently done at the site using a horizontal pipe infiltration system, and system expansion has been proposed with a target rate of 12 l/s using small-diameter wells as one possible option. A short-duration single-well field recharge experiment (recharge rate 1.3–3.5 l/s) was performed (recharge by gravity only). Numerical modeling of the injection test was used to estimate hydraulic conductivity (K). Quasi-steady-state, single-well recharge simulations for different locations, as well as a long-term transient simulation, were performed using the K value calibrated from the field injection test. Results indicate that a recharge capacity of 4.1 l/s was achievable with a maximum head rise of 0.2 m at the injection well. Finally, simulations were performed for three different well fields (4, 6 and 8 wells, respectively) designed to infiltrate a target rate of 12 l/s. The experimental and numerical assessments, supported by a cost analysis of the small-diameter wells, indicate that the small-diameter wells are a viable, cost-effective recharge approach at this and other similar sites.  相似文献   

7.
以回灌过程中渗透系数衰减模型为基础,推导了不同回扬次数的渗透系数解析表达式;将其应用于Theis公式,获得了考虑渗透系数衰减以及暂时性堵塞率条件下回灌与回扬物理过程中含水层压强的解析表达式,更准确地刻画了回灌与回扬的物理机制。计算结果表明:在连续回灌不回扬过程中,井内灌压增长符合指数曲线特征,而采取回扬措施后,由指数连续上升转变为间断式阶梯上升;回扬次数越多,灌压下降越明显,但灌压变化幅度随回扬次数的递增而减小。根据解析解定义的两种堵塞率的结果,可以实现利用实验判断不同成分回灌水源对含水层堵塞机理的分析,从而达到科学制定回灌水源标准的目的。  相似文献   

8.
The present study indicates that the factors controlling the hydraulic relation between surface water and groundwater at the western lake shoreline change from one locality to another. This depends upon the lithological characteristics and the major structures. In the southern sectors, sedimentation at the bottom and sides of the lake prevents the water movement to the Nubian sandstone aquifer. The potentiometric map reveals that the water level altitudes range between 170 m in the vicinity of the lakeshore line and 110 m west of the lake. The groundwater flow lines show that the main recharge to the aquifer comes from the southwest direction, as well as from the lake inland to variable distances (about 30 Km). During the present study, Darcy’s law was applied to calculate the recharge from the western shoreline of Lake Nasser to the adjacent Nubian aquifer. The maximum value of seepage was at Garf Hussein (27.71?×?106 m³/year), which may be related to high permeability and hydraulic gradient. Also, it may be related to the N–S strike faults that cut the area on both sides of the Lake, and the groundwater is expected to have free circulation through the faults of this trend. The minimum value was recorded in Adindan section (0.61?×?106 m³/year). This may be related to the limited recharge from the lake to the aquifer, due to the sedimentation that dislocates this recharge.  相似文献   

9.
以颗粒状钠基膨润土防水毯为研究对象,采用改造的GDS全自动环境岩土渗透仪开展渗透试验,研究温度和压力对渗透系数的影响。研究表明:低围压下膨润土防水毯的渗透系数随温度的增加而减小,温度较高时趋于平缓或略有增大;围压增为100 kPa时,渗透系数随温度的增加而增大。固有渗透率随温度的增加而减小;低围压下固有渗透率减小更显著,仅考虑流体物理性质变化的渗透系数估算值与实测值有很大差异。膨润土吸附结合水量随温度的升高而减小,不能解释膨润土防水毯渗透系数和固有渗透率随温度的变化规律。当温度升高时,粒间孔隙减小且颗粒状膨润土分解成凝胶态蒙脱石颗粒,在低围压下凝胶态蒙脱石颗粒层间距离减小,是渗透系数和固有渗透率随温度的升高而减小的主要原因。  相似文献   

10.
This paper presents a finite‐element (FE) model for simulating injection well testing in unconsolidated oil sands reservoir. In injection well testing, the bottom‐hole pressure (BHP) is monitored during the injection and shut‐in period. The flow characteristics of a reservoir can be determined from transient BHP data using conventional reservoir or well‐testing analysis. However, conventional reservoir or well‐testing analysis does not consider geomechanics coupling effects. This simplified assumption has limitations when applied to unconsolidated (uncemented) oil sands reservoirs because oil sands deform and dilate subjected to pressure variation. In addition, hydraulic fracturing may occur in unconsolidated oil sands when high water injection rate is used. This research is motivated in numerical modeling of injection well testing in unconsolidated oil sands reservoir considering the geomechanics coupling effects including hydraulic fracturing. To simulate the strong anisotropy in mechanical and hydraulic behaviour of unconsolidated oil sands induced by fluid injection in injection well testing, a nonlinear stress‐dependent poro‐elasto‐plastic constitutive model together with a strain‐induced anisotropic permeability model are formulated and implemented into a 3D FE simulator. The 3D FE model is used to history match the BHP response measured from an injection well in an oil sands reservoir. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

11.
The present paper provides a case study of the assessment of the potential for CO2 storage in the deep saline aquifers of the Bécancour region in southern Québec. This assessment was based on a hydrogeological and petrophysical characterization using existing and newly acquired core and well log data from hydrocarbon exploration wells. Analyses of data obtained from different sources provide a good understanding of the reservoir hydrogeology and petrophysics. Profiles of formation pressure, temperature, density, viscosity, porosity, permeability, and net pay were established for Lower Paleozoic sedimentary aquifers. Lateral hydraulic continuity is dominant at the regional scale, whereas vertical discontinuities are apparent for most physical and chemical properties. The Covey Hill sandstone appears as the most suitable saline aquifer for CO2 injection/storage. This unit is found at a depth of more than 1 km and has the following properties: fluid pressures exceed 14 MPa, temperature is above 35 °C, salinity is about 108,500 mg/l, matrix permeability is in the order of 3 × 10?16 m2 (0.3 mDarcy) with expected higher values of formation-scale permeability due to the presence of natural fractures, mean porosity is 6 %, net pay reaches 282 m, available pore volume per surface area is 17 m3/m2, rock compressibility is 2 × 10?9 Pa?1 and capillary displacement pressure of brine by CO2 is about 0.4 MPa. While the containment for CO2 storage in the Bécancour saline aquifers can be ensured by appropriate reservoir characteristics, the injectivity of CO2 and the storage capacity could be limiting factors due to the overall low permeability of aquifers. This characterization offers a solid basis for the subsequent development of a numerical hydrogeological model, which will be used for CO2 injection capacity estimation, CO2 injection scenarios and risk assessment.  相似文献   

12.
Contamination of the Paleozoic carbonate aquifer at Walkerton (Ontario, Canada) by pathogenic bacteria following heavy rain in May 2000 resulted in 2,300 illnesses and seven deaths. Subsequent tracer testing showed that there was rapid groundwater flow in the aquifer, and also rapid exchange between the aquifer and the ground surface. Electrical conductivity (EC) profiling during a 3-day pumping test showed that most flow was through bedding-plane fractures spaced about 10 m apart, that there were substantial contrasts in EC in the major fracture flows, and that there were rapid changes over time. Total coliform sampling revealed transient groundwater contamination, particularly after heavy rain and lasting up to a few days. These characteristics can be understood in terms of the dual-porosity nature of the aquifer. Most of the storage is in the matrix, but this can be considered to be static in the short term. Almost all transport is through the fracture network, which has rapid groundwater flow (~100 m/day) and rapid transmission of pressure pulses due to the high hydraulic diffusivity. Rapid recharge can occur through thin and/or fractured overburden and at spring sites where flow is reversed by pumping during episodes of surface flooding. These characteristics facilitated the ingress of surface-derived bacteria into the aquifer, and their rapid transport within the aquifer to pumping wells. Bacterial presence is common in carbonate aquifers, and this can be explained by the well-connected, large-aperture fracture networks in these dual-porosity aquifers, even though many, such as at Walkerton, lack karst landforms.  相似文献   

13.
The purpose of this study is to evaluate the groundwater-withdrawal potential of the Fraser River watershed, a mountainous drainage system in north-central Colorado. Laboratory tests, field investigations, and numerical modeling are conducted to present a quantitative understanding of the watershed’s groundwater-flow system. Aquifer hydraulic conductivity values obtained from aquifer tests range from 1E?5 to 1E?3 m/s. Groundwater withdrawal is concentrated in channel-fill deposits of the Troublesome Formation within the Fraser basin. A steady state groundwater-flow model of the Fraser River watershed is developed and calibrated using 24 observation wells in the Fraser River valley and estimated baseflow of the Fraser River. Modeling results suggest that surface recharge is the major source of groundwater in the watershed. Groundwater exits the watershed through evapotranspiration and discharge to rivers. Transient groundwater-flow modeling evaluates future withdrawal scenarios using the hydraulic head distribution from the steady state model as the initial condition. Drawdown within Troublesome Formation aquifers from the current pumping schedule approaches 2 m. When the daily pumping rate is doubled, drawdown approaches 4 m. The radius of influence is hundreds of meters to 1 km. Pumping wells withdraw approximately 2 and 15 % of groundwater flowing through the well field for hydraulic conductivity of 1E?3 and 1E?5 m/s, respectively. This study suggests that the groundwater system at the Fraser Valley could sustain current and future withdrawals, given that the current recharge condition is maintained.  相似文献   

14.
Results of compressibility and hydraulic conductivity testing performed under different levels of average vertical stress were used to determine the appropriate tire chips size (in particular aspect ratio) and tire chip—gravel random state mix combination. Proper sidewall treatment was provided to reduce side wall friction up to minimum level and constant head conditions were maintained with appropriate design flow rate. Results showed that tire chips (length 25 mm, aspect ratio 1) mixed with 40 mm gravel in the random state in mixing ratio of 3:1 (ds:dg) was observed to undergo minimum strain, maximum hydraulic conductivity and hence free drainage even under high vertical stress levels. By selecting tire chips of appropriate aspect ratio and optimum mix combination for the construction of drainage layer of MSW landfill leachate collection system lower strain response, higher hydraulic conductivity values and relatively free drainage even under anticipated higher vertical stress levels may be achieved.  相似文献   

15.
With the completion of South-North Water Transfer Project in China, plenty of high quality water will be transported to Beijing. To restore the groundwater level in Beijing, part of transferred water is planned to be used for artificial recharge. Clogging is an unavoidable challenge in the artificial recharge process. Therefore, a test is designed to analyse clogging duration and scope of influence and to test the reinjection properties of different recharge media. The test employs the self-designed sand column system with variable spacing and section monitoring, composed of four parts: Sand column, water-supply system, pressure-test system and flow-test system, to simulate the clogging of artificial recharge of sand and gravel pits. The hydraulic conductivity levels of all sand column sections are obtained to analyse the clogging of the injection of different concentrations in media of different particle sizes. In this experiment, two kinds of media are used–round gravel from sand and gravel pit in Xihuang village and the sand from sand and gravel pit by the Yongding River. The concentrations of recharge fluid are respectively 0.5 g/L and 1 g/L. The results show that clogging usually lasts for 20 hrs., and the hydraulic conductivity drops to the original 10%. Clogging usually occurs at 0–12 cm section of the sand column. The scope of influence is 0–60 cm. In column 3 and 4, whose average particle sizes are larger, section 20–50 cm also suffers from clogging, apart from section 0–12 cm. The effective recharge times are respectively 33 hrs. in column 1, 14 hrs. in column 2, 12 hrs. in column 3 and 12 hrs. in column 4. The larger the average particle size is, the quicker the clogging occurs. In media of larger particles, the change in suspension concentration does not have significant influence on the development of clogging. In conclusion, it is suggested that during artificial recharge, the conditions of reinjection medium should be fully considered and effective method of recharge be employed in order to improve effective recharge time.  相似文献   

16.
Geothermal springs are some of the most obvious indicators of the existence of high-temperature geothermal resources in the subsurface. However, geothermal springs can also occur in areas of low average subsurface temperatures, which makes it difficult to assess exploitable zones. To address this problem, this study quantitatively analyzes the conditions associated with the formation of geothermal springs in fault zones, and numerically investigates the implications that outflow temperature and discharge rate from geothermal springs have on the geothermal background in the subsurface. It is concluded that the temperature of geothermal springs in fault zones is mainly controlled by the recharge rate from the country rock and the hydraulic conductivity in the fault damage zone. Importantly, the topography of the fault trace on the land surface plays an important role in determining the thermal temperature. In fault zones with a permeability higher than 1 mD and a lateral recharge rate from the country rock higher than 1 m3/day, convection plays a dominant role in the heat transport rather than thermal conduction. The geothermal springs do not necessarily occur in the place having an abnormal geothermal background (with the temperature at certain depth exceeding the temperature inferred by the global average continental geothermal gradient of 30 °C/km). Assuming a constant temperature (90 °C here, to represent a normal geothermal background in the subsurface at a depth of 3,000 m), the conditions required for the occurrence of geothermal springs were quantitatively determined.  相似文献   

17.
The influence of alkaline aqueous solutions on the properties of bentonite was investigated to evaluate the performance of bentonitic engineered barriers when contacted with alkaline groundwater. Batch and hydraulic conductivity tests were conducted on Na-bentonite using six different alkaline aqueous solutions. For the batch tests, almost no change in the montmorillonite fraction of the bentonite was observed after reacting with alkaline solutions (pH = 8.4–13.1), regardless of the solution type. On the other hand, aluminosilicate minerals (e.g., albite) were dissolved and secondary minerals (e.g., anorthite) were formed in alkaline NaOH solutions (pH > 13). The cation (Ca or Na) concentration primarily affected the swelling properties of bentonite rather than the pH of the solution, which was comparable to the results of the hydraulic conductivity tests. For the Ca solutions, the hydraulic conductivity of the bentonite specimen to the 0.02 mol/L Ca(OH)2 solution (6.5 × 10?9 cm/s) was approximately an order of magnitude lower than that of the bentonite specimen to the 0.02 mol/L Ca(OH)2 + 1 mol/L CaCl2 solution (5.0 × 10?8 cm/s), whereas the hydraulic conductivity to the 0.02 mol/L Ca(OH)2 + 1 mol/L CaCl2 solution (pH = 11.3) (5.0 × 10?8 cm/s) was slightly higher than that to the 1 mol/L CaCl2 solution (pHi = 8.4) (4.4 × 10?8 cm/s). For the NaOH solutions with pH > 13, the hydraulic conductivity of the bentonite specimen decreased with increasing Na concentration, suggesting that the effect of Na concentration was more dominant than that of permeant pH.  相似文献   

18.
Laboratory tests were carried out on compacted granite residual soil treated with 0 to 15% Palm Oil Fuel Ash (POFA), with a view to evaluate its hydraulic conductivity for its application in landfilling. The Soil–POFA mixtures were compacted using both Standard and Modified Proctors compactive efforts at 2% dry of Optimum Moulding water Content (?2%), at Optimum Moulding water Content (0%), at 2 and 4% on the wet side of Optimum Moulding water Content (+2 and +4%). The samples were permeated with water and the effect of moulding water content; compactive effort and POFA content were examined. The samples that met the minimum threshold of 1 × 10?9 m/s were used in plotting the acceptable zones criterion at various POFA mixtures. The results gave indications of reduction in the hydraulic conductivity values, with increase in compactive efforts, moulding water content and POFA content up to about 10%. This was the most suitable soil–POFA mixture for the hydraulic application.  相似文献   

19.
地下水人工回灌过程中多孔介质悬浮物堵塞实验   总被引:3,自引:1,他引:2  
地下水人工回灌技术的发展与推广常因其回灌过程中物理、化学及生物作用产生的入渗介质堵塞现象而受到严重制约。针对堵塞现象中最常见且最主要的悬浮物堵塞问题,采用室内模拟实验方法,通过将悬浊水连续注入均质的石英砂柱中,来刻画多孔介质中悬浮物堵塞的现象及发生的过程,并分析其发展规律,同时量化计算了堵塞速率。实验结果表明:回灌15 h左右表层介质渗透系数开始降低,即堵塞在表层开始发生,并随时间增加不断向深部发展;连续回灌100 h后表层渗透系数趋于稳定,进入介质内部悬浮物的量减少,内部堵塞发展也趋于稳定,此时堵塞主要在入渗深度10 cm左右的范围内。计算不同堵塞层的堵塞速率λ:表层0~1 cm的λ最大,为0.038 3 h-1,λ随入渗深度增加而减小。对于介质整体的渗透性而言,其降低明显滞后于表层介质,但随时间发展主要受堵塞层的控制。  相似文献   

20.
A pressure cell apparatus has been developed in this research work to study the long-term hydro-mechanical behaviour of cemented paste backfill (CPB) cured under applied stress. The samples are cured for 7, 28, 90 and 150 days and the evolution of their mechanical, hydraulic, physical and microstructural properties is studied. Also, the suction, temperature and electrical conductivity are monitored for a period of 150 days of curing. The testing and monitoring programmes are conducted in undrained conditions, with and without pressure application. The obtained results show that the curing stress affects the hydro-mechanical behaviour of CPB for up to 28 days. Within this curing period, the CPB exhibits enhanced hydro-mechanical performance. However, application of sustained excessive curing stress onto the CPB samples induces the propagation of microcracks in the backfill structure, thus causing lower mechanical strength and higher fluid permeability at the more advanced ages. Furthermore, the mineralogical and chemical compositions of the tailings (e.g., sulfidic tailings) can significantly alter the mechanical strength properties (uniaxial compressive strength and elastic modulus) and the permeability of the CPB. The evolution of coupled factors and characteristics of the CPB at an early age control and influence its long-term behaviour and performance.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏