首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 500 毫秒
1.
Twenty polymeric tubings were filled with a test solution containing eight organic solutes. The test solutions were monitored for losses, indicating that sorption had occurred, and for signs that leaching of organic constituents had occurred. The tubings tested included seven flexible products and eight fluoropolymers. Among the rigid tubings tested, three fluoropolymers (fluorinated ethylene propylene [FEP], FEP-lined polyethylene, polyvinylidene fluoride) were the least sorptive tubings. However, even these tubings readily sorbed some of the analytes. Among the flexible tubings tested, a fluoroelastomer tubing and a tubing made of a copolymer of vinylidene fluoride and hexafluoropropylene were the least sorptive.
Several of the tubings tested leached constituents into the test solution. The polyurethane, polyamide, flexible polyvinyl chloride (PVC), polyester-lined PVC, and silicone-modified thermoplastic elastomer tubings were found to leach the most constituents. We were unable to detect any constituents leaching from the polyethylene tubings, the rigid fluoropolymer tubings, and one of the plasticized polypropylene tubings.  相似文献   

2.
In these studies, the efficiency of various decontamination protocols was tested on small pieces of materials commonly used in ground water sampling devices. Three materials, which ranged in ability to sorb organic solutes, were tested: stainless steel (SS), rigid polyvinyl chloride (PVC), and polytetrafluoroethylene (PTFE). The test pieces were exposed to two aqueous test solutions: One contained three volatile organic compounds (VOCs) and one nitroaromatic compound, and the other contained four pesticides. Also, three types of polymeric tubing were exposed to pesticide solutions. Generally, the contact times were 10 minutes and 24 hours for sorption and desorption.
The contaminants were removed from the nonpermeable SS and the less-sorptive rigid PVC test pieces simply by washing with a hot detergent solution and rinsing with hot water. Additional treatment was required for the PTFE test pieces exposed to the VOCs and for the low-density polyethylene (LDPE) tubing exposed to the pesticide test solution. Solvent rinsing did not improve removal of the three VOCs from the PTFE and only marginally improved removal of the residual pesticides from the LDPE. However, a hot water and detergent wash and rinse followed by oven drying at approximately 105°C was effective for removing the VOCs from the PTFE and substantially reduced pesticide contamination from the LDPE.  相似文献   

3.
A simple, inexpensive sampling pump has lately come into use in ground water monitoring. The pump is referred to as an inertial pump; its only downhole components are a foot valve connected to a length of tubing or pipe. The operating principle of the pump is based on the inertia of a column of water within the riser tubing. Ground water is drawn through the foot valve and up the riser tubing by rapid up and down movements of the tubing. This pumping method is not new, but has only recently been applied to monitoring wells. Foot valves are available in a variety of materials and sizes and can be used in monitoring wells as small as 19mm (3/4 inch) I.D. Flexible polyethylene or Teflon® tubing, and in some cases stainless steel tubing or rigid PVC pipe, is used as the riser. The inertial pump satisfies most of the criteria normally cited for an "ideal" sampling device. The pump is easy to operate, reliable, durable, portable, and virtually maintenance-free. It can be operated manually from as deep as 40m or from as deep as 60m using a motor drive. The pump is inexpensive, and therefore suitable for use as a dedicated sampling pump. Recent tests have shown the pump to be suitable for sampling volatile organics. The inertial pump has a high flow capacity and performs well in silty/sandy environments, which makes it useful for developing and purging monitoring wells. It may also be used to perform field hydraulic conductivity tests.  相似文献   

4.
Studies have shown that materials, such us polytetra-fluoroethylene (PTFE), rigid polyvinyl chloride (rigid PVC). flexible polyvinyl chloride (flexible PVC), stainless steel (SS). low-density polyethylene (LDPE), and high-density polyethylene (HDPE), have the potential to influence certain analyte concentrations in ground water samples. The effects of HDPE, LDPE, PTFE, rigid PVC, and SS on aqueous concentrations of nitrate-N, atrazine, deethylatrazine (DEA), and deisopropylatrazine (DIA) were evaluated in a field study A laboratory study was conducted to evaluate sorption of atrazine DEA, DIA, cyanazine, alachlor, metolachlor, and butachlor to PTFE, HDPE, and SS materials. Butachlor is rarely use in the United States, but was included because of its expected high sorptivity. No significant differences between HDPE, LDPE, PTFE, rigid PVC, and SS were determined for any of the analytes tested in the field study. In the laboratory study, sorption of DIA to PTFE and SS was significant at 2.6 × 10−5 and 4.1 × 10−5μg/m2 respectively. Sorption of DIAA to HDPE was not significantly > 0 sorption of all other compounds to HDPE, PTFE, and SS were also not significantly >0. Results of the two studies indicate that for these analytes (relatively polar or ionized compounds), representative ground water samples are not dependent on the materials used for multilevel sampler construction. When considering these compounds, it appears that the least expensive materials (HDPE, rigid PVC, and LDPE) are good choices for the construction of ground water monitoring wells.  相似文献   

5.
The horizontal reactive media treatment well (HRX Well®) uses directionally drilled horizontal wells filled with a treatment media to induce flow-focusing behavior created by the well-to-aquifer permeability contrast to passively capture proportionally large volumes of groundwater. Groundwater is treated in situ as it flows through the HRX Well and downgradient portions of the aquifer are cleaned via elution as these zones are flushed with clean water discharging from the HRX Well. The HRX Well concept is particularly well suited for sites where long-term mass discharge control is a primary performance objective. This concept is appropriate for recalcitrant and difficult-to-treat constituents, including chlorinated solvents, per- and polyfluoroalkyl substances (PFAS), 1,4-dioxane, and metals. A full-scale HRX Well was installed and operated to treat trichloroethene (TCE) with zero valent iron (ZVI). The model-predicted enhanced flow through the HRX Well (compared to the flow in and equivalent cross-sectional area orthogonal to flow in the natural formation before HRX Well installation) and treatment zone width was consistent with flows and widths estimated independently by point velocity probe (PVP) testing, HRX Well tracer testing, and observed treatment in downgradient monitoring wells. The actual average capture zone width was estimated to be between 45 and 69 feet. Total TCE mass discharge reduction was maintained through the duration of the performance monitoring period and exceeded 99.99% (%). Decreases in TCE concentrations were observed at all four downgradient monitoring wells within the treatment zone (ranging from 50 to 74% at day 436), and the first arrival of treated water was consistent with model predictions. The field demonstration confirmed the HRX Well technology is best suited for long-term mass discharge control, can be installed under active infrastructure, requires limited ongoing operation and maintenance, and has low life cycle energy and water requirements.  相似文献   

6.
A New Multilevel Ground Water Monitoring System Using Multichannel Tubing   总被引:5,自引:0,他引:5  
A new multilevel ground water monitoring system has been developed that uses custom-extruded flexible 1.6-inch (4.1 cm) outside-diameter (O.D.) multichannel HOPE tubing (referred to as Continuous Multichannel Tubing or CMT) to monitor as many as seven discrete zones within a single borehole in either unconsolidated sediments or bedrock. Prior to inserting the tubing in the borehole, ports are created that allow ground water to enter six outer pie-shaped channels (nominal diameter = 0.5 inch [1.3 cm]) and a central hexagonal center channel (nominal diameter = 0.4 inch [1 cm]) at different depths, facilitating the measurement of depth-discrete piezometric heads and the collection of depth-discrete ground water samples. Sand packs and annular seals between the various monitored zones can be installed using conventional tremie methods. Alternatively, bentonite packers and prepacked sand packs have been developed that are attached to the tubing at the ground surface, facilitating precise positioning of annular seals and sand packs. Inflatable rubber packers for permanent or temporary installations in bedrock aquifers are currently undergoing site trials. Hydraulic heads are measured with conventional water-level meters or electronic pressure transducers to generate vertical profiles of hydraulic head. Ground water samples are collected using peristaltic pumps, small-diameter bailers, inertial lift pumps, or small-diameter canister samplers. For monitoring hydrophobic organic compounds, the CMT tubing is susceptible to both positive and negative biases caused by sorption, desorption, and diffusion. These biases can be minimized by: (1) purging the channels prior to sampling, (2) collecting samples from separate 0.25-inch (0.64 cm) O.D. Teflon sampling tubing inserted to the bottom of each sampling channel, or (3) collecting the samples downhole using sampling devices positioned next to the intake ports. More than 1000 CMT multilevel wells have been installed in North America and Europe to depths up to 260 feet (79 m) below ground surface. These wells have been installed in boreholes created in unconsolidated sediments and bedrock using a wide range of drilling equipment, including sonic, air rotary, diamond-bit coring, hollow-stem auger, and direct push. This paper presents a discussion of three field trials of the system, demonstrating its versatility and illustrating the type of depth-discrete data that can be collected with the system.  相似文献   

7.
A model for the diffusion of gases through polymeric tubing was derived which predicts that the amount of gas transferred is proportional to the tubing length and inversely proportional to the pumping rate. The model was experimentally tested and confirmed for oxygen transfer through fluorinated ethylene-propylene copolymer (FEP) tubing using tubing lengths and flow rates typical of ground water sampling. Diffusion can introduce measurable concentrations of oxygen into initially anoxic water. Diffusive loss of carbon dioxide from water that is oversaturated with respect to atmospheric CO2 does not measurably affect pH under similar usage conditions.  相似文献   

8.
This series of experiments was initiated to determine the overall suitability of three alternative polymeric well casing materials (fluorinated ethylene propylene [FEP], fiberglass-reinforced epoxy [FRE], and fiberglass-reinforced plastic [FRP]) for use in ground water monitoring wells and to compare these materials with polyvinyl chloride (PVC) and polytetrafluoroethylene (PTFE) well casings. This paper focuses on sorption and leaching of metals.
Generally, the fiberglass materials leached more metal contaminants than PVC, FEP, and PTFE. However, with one exception (Pb leaching from FRP), leached concentrations were below maximum allowable limits set by the U.S. Environmental Protection Agency (EPA) for drinking water. With respect to sorption, none of the polymers sorbed the anions tested, but all of them sorbed one or more of the cations tested. FEP and PTFE were much less sorptive than the other materials.  相似文献   

9.
A tracer test was conducted to characterize the flow of groundwater across a permeable reactive barrier constructed with plant mulch (a biowall) at the OU‐1 site on Altus Air Force Base, Oklahoma. This biowall is intended to intercept and treat groundwater contaminated by trichloroethylene (TCE) in a shallow aquifer. The biowall is 139‐m long, 7.3‐m deep, and 0.5‐m wide. Bromide was injected from an upgradient well into the groundwater as a conservative tracer, and was subsequently observed breaking through in monitoring wells within and downgradient of the biowall. The bromide breakthrough data demonstrate that groundwater entering the biowall migrated across it, following the slope of the local groundwater surface. The average seepage velocity of groundwater was approximately 0.06 m/d. On the basis of the Darcy velocity of groundwater and geometry of the biowall, the average residence time of groundwater in the biowall was estimated at 10 d. Assuming all TCE removal occurred in the biowall, the reduction in TCE concentrations in groundwater across the biowall corresponds to a first‐order attenuation rate constant in the range of 0.38 to 0.15 per d. As an independent estimate of the degradation rate constant, STANMOD software was used to fit curves through data on the breakthrough of bromide and TCE in selected wells downgradient of the injection wells. Best fits to the data required a first‐order degradation rate constant for TCE removal in the range of 0.13 to 0.17 per d. The approach used in this study provides an objective evaluation of the remedial performance of the biowall that can provide a basis for design of other biowalls that are intended to remediate TCE‐contaminated groundwater.  相似文献   

10.
Micropurge sampling of ground water wells has been suggested as a possible replacement to traditional purge and sample methods. To compare methods, duplicate ground water samples were collected at two field sites using iraditional and micropurge methods. Samples were analyzed for selected organic and inorganic constituents, and the results were compared statistically. Analysis of the data using the nonparametric sign test indicates that within a 95 percent confidence interval, there was no significant difference between the two methods for the site contaminants and the majority of analytes. These analytical results were supported by visual observations with the colloidal borescope, which demonstrated impacts on the flow system in the well when using traditional sampling methods. Under selected circumstances, the results suggest replacing traditional sampling with micropurging based on reliability, cost, and waste minimization.  相似文献   

11.
Hydrogeologic and ground water quality data obtained from a gas-driven multilevel sampler system and a polyvinyl chloride (PVC) monitoring well nest with the same aquifer communication intervals are compared. All monitoring points are in close proximity to each other. The study was conducted at an eight-acre uncontrolled hazardous waste site. The site is located in an alluvial valley composed of approximately 40 feet of alluvium overlying shale bedrock. The ground water at the site is contaminated with various organic constituents. A ground water monitoring network consisting of 26 conventional monitoring wells, nine observation well points, and six multilevel gas-driven samplers was established to characterize the hydrogeologic regime and define the vertical and horizontal extent of contamination in the vicinity of the abandoned chemical plant. As part of this study, a multilevel monitoring system was installed adjacent to a well nest. The communication zones of the multilevel samplers were placed at the same elevation as the sand packs of the well nest. The multilevel sampler system and well nest are located in a contaminated area directly downgradient of the site. A comparison of the vertical head distribution and ground water quality was performed between the well nest and the multilevel sampling system. The gas-driven multilevel sampling system consists of three gas-driven samplers that monitor separate intervals in the unconsolidated materials. The well nest, composed of two PVC monitoring wells in separate boreholes, has the same communication interval as the other two gas-driven samplers. Hydraulic head information for each multilevel sampler was obtained using capillary tubing. This was compared with heads obtained from the well nest utilizing an electric water level indicator. Chemical analyses from the PVC and multilevel sampler wells were performed and compared with one another. The analyses included organic acids, base neutrals, pesticides, PCBs, metals, volatile organics, TOX, TOC, CN, pH and specific conductance.  相似文献   

12.
Thermal methods are promising for remediating fractured geologic media contaminated with volatile organic compounds, and the success of this process depends on the coupled heat transfer, multiphase flow, and thermodynamics. This study analyzed field‐scale removal of trichloroethylene (TCE) and heat transfer behavior in boiling fractured geologic media using the multiple interacting continua method. This method can resolve local gradients in the matrix and is less computationally demanding than alternative methods like discrete fracture‐matrix models. A 2D axisymmetric model was used to simulate a single element of symmetry in a repeated pattern of extraction wells inside a large heated zone and evaluate effects of parameter sensitivity on contaminant recovery. The results showed that the removal of TCE increased with matrix permeability, and the removal rate was more sensitive to matrix permeability than any other parameter. Increasing fracture density promoted TCE removal, especially when the matrix permeability was low (e.g., <10?17 m2). A 3D model was used to simulate an entire treatment zone and the surrounding groundwater in fractured material, with the interaction between them being considered. Boiling was initiated in the center of the upper part of the heated region and expanded toward the boundaries. This boiling process resulted in a large increase in the TCE removal rate and spread of TCE to the vadose zone and the peripheries of the heated zone. The incorporation of extraction wells helped control the contaminant from migrating to far regions. After 22 d, more than 99.3% of TCE mass was recovered in the simulation.  相似文献   

13.
Bacteria that degrade natural organic matter in groundwater contain oxygenase enzymes that can co‐oxidize trichloroethene (TCE). This degradation pathway is promising for large dilute plumes, but its evaluation is limited because the density of the bacteria with oxygenase enzymes has not been correlated to field scale rates of degradation. A 14C–TCE assay was developed to determine pseudo first‐order rate constants for the aerobic co‐oxidation of TCE in groundwater. The assay involved incubating 14C–TCE in samples of groundwater contained in 160 mL serum bottles, and monitoring the accumulation of radiolabel in degradation products. A first‐order rate constant for co‐oxidation was extracted from the rate of accumulation of 14C in products, accounting for volumetric changes in the serum bottles due to sampling and subsequent changes to the distribution of TCE between the aqueous and gaseous phases. Of the groundwater samples evaluated from 19 wells at five sites, eight samples at three sites had 14C product accumulation rates that exceeded the accumulation rate in filter‐sterilized groundwater controls. First‐order rate constants ranged from 2.65 to 0.0066 year?1, which is equivalent to half‐lives of 0.26 to 105 years. Groundwater samples from a few of the wells in which co‐oxidation occurred had volatile organic contaminants in addition to TCE; their presence may have induced the oxygenase enzymes that are needed for TCE co‐oxidation. 14CO2 represented ~37% to 97% of the 14C products that accumulated; the balance of the products was soluble and non‐volatile.  相似文献   

14.
Influence of Casing Materials on Trace-Level Chemicals in Well Water   总被引:1,自引:0,他引:1  
Four well casing materials — polyvinyl chloride (PVC), polytetrafluoroethylene (PTFE), and stainless steel 304 (SS 304) and 316 (SS 316) — were examined to determine their suitability for monitoring inorganic and organic constituents in well water.
The inorganic study used a factorial design to test the effect of concentration of mixed metals (arsenic [As], chromium [Cr], lead [Pb], and cadmium [Cd]), pH, and organic carbon. Sample times were 0.5, 4, 8, 24, and 72 hours. Except for slow loss of Pb, PTFE well casings had no significant effect on the concentration of metals in solution. For the other casings, changes in analyte concentration often exceeded 10 percent in eight hours or less and, thus, could bias analyses of samples taken from wells constructed with these materials. Specifically, PVC casings sorbed Pb and leached Cd; SS 316 casings sorbed As and Pb and leached Cd; and SS 304 casings sorbed As, Cr, and Pb and leached Cd. Both stainless steel casing materials showed markedly poorer performance than the PVC casings.
The well casings were also tested for sorption/desorption of 10 organic substances from the following classes: chlorinated alkehes, chlorinated aromatics, nitroaromatics and nitramines. Sample times were 0, 1, 8, 24, and 72 hours, seven days, and six weeks. There were no detectable losses of analytes in any of the sample solutions containing stainless steel well casings. Significant loss of some analytes was observed in sample solutions containing plastic casings, although losses were always more rapid with the PTFE casings than with PVC. Chlorinated organic substances were lost most rapidly. For samples containing PTFE casings, losses of some of these compounds were rapid enough (>10 percent in eight hours) to be of concern for ground water monitoring. Losses of hydrophobic organic constituents in samples containing PTFE casings were correlated with the compound's octanol/water partition coefficient.  相似文献   

15.
Experiments simulating the dynamics of compliance sampling via a monitoring well were performed to assess the effects of common well screen materials (rigid polyvinyl chloride, polytetrafluoroethylene, stainless steel 304. and stainless steel 316) on several metals and tri- chloroethylene (TCE) in ground water. This was achieved by using a continuous flow-through chamber system capable of exposing monitoring well screens to ground water for periods ranging from 0.25 to 8 hours. The findings of this study are more representative than static laboratory experiments for assessing the potential effects well casing materials have on ground water samples. Under dynamic flow conditions stainless steel 304 and 316 screens were found to influence solution concentrations of Pb, Cd, Cr, Ni, and Fe, while ground water TCE concentrations were not affected by any of the materials tested.  相似文献   

16.
Waste disposal sites with volatile organic compounds (VOCs) frequently contain contaminants that are present in both the ground water and vadose zone. Vertical sampling is useful where transport of VOCs in the vadose zone may effect ground water and where steep vertical gradients in chemical concentrations are anticipated. Designs for combination ground water and gas sampling wells place the tubing inside the casing with the sample port penetrating the casing for sampling. This physically interferes with pump or sampler placement. This paper describes a well design that combines a ground water well with gas sampling ports by attaching the gas sampling tubing and ports to the exterior of the casing. Placement of the tubing on the exterior of the casing allows exact definition of gas port depth, reduces physical interference between the various monitoring equipment, and allows simultaneous remediation and monitoring in a single well. The usefulness and versatility of this design was demonstrated at the Idaho National Engineering and Environmental Laboratory (INEEL) with the installation of seven wells with 53 gas ports, in a geologic formation consisting of deep basalt with sedimentary interbeds at depths from 7.2 to 178 m below land surface. The INEEL combination well design is easy to construct, install, and operate.  相似文献   

17.
Monitored natural attenuation (MNA) is commonly used as a remedy for trichloroethene (TCE) in anaerobic groundwater; however, MNA has not been applied to TCE contamination in aerobic groundwater. Under aerobic conditions, bacteria initiate the degradation of many organic substances with oxygenase enzymes. Several of these enzymes are known to degrade TCE through a fortuitous reaction known as cometabolism. There are commercially available qPCR assays that can determine the number of gene copies of these enzymes. If the qPCR assay could be used to predict the first-order rate constant for cometabolism of TCE, the qPCR assay could be used to screen sites to determine whether MNA was a plausible remedy for TCE contamination. This study reevaluated data from water samples that were collected from 19 wells on five sites in Minnesota, New York, and Utah. Data had previously been published on the rate constant for cometabolism of TCE in the water samples as determined by a 14C-assay and the abundance of gene copies for five enzymes that cometabolize TCE as determined using a qPCR assay. The Michaelis-Menten (Haldane) kinetic parameters for cometabolism of TCE and the abundance of DNA for the five oxygenase enzymes were used to predict the rate constant for cometabolism of TCE. The predicted rate constants were evaluated and validated by comparing them to the rate constants derived from the 14C-assay. For predicted rate constants greater than 0.003 per year, the predicted rate constants agreed with the measured rate constants within a factor of three. The qPCR assay serves as a convenient screening tool to determine whether MNA is a plausible remedy for an aerobic plume of TCE.  相似文献   

18.
High‐resolution soil and groundwater monitoring was performed to assess the long‐term impacts of bioremediation using bioaugmentation with a dechlorinating microbial consortium (and sodium lactate as the electron donor) in a well‐characterized trichloroethene (TCE) dense nonaqueous phase liquid (DNAPL) source area. Monitoring was performed up to 3.7 years following active bioremediation using a high‐density monitoring network that included several discrete interval multi‐level sampling wells. Results showed that despite the absence of lactate, lactate fermentation transformation products, or hydrogen, biogeochemical conditions remained favorable for the reductive dechlorination of chlorinated ethenes. In locations where soil data showed that TCE DNAPL sources persisted, local contaminant rebound was observed in groundwater, whereas no rebound or continuous decreases in chlorinated ethenes were observed in locations where DNAPL sources were treated. While ethene levels measured 3.7 years after active treatment suggested relatively low (2 to 30%) dechlorination of the parent TCE and daughter products, carbon stable isotope analysis showed that the extent of complete dechlorination was much greater than indicated by ethene generation and that the estimated first‐order rate constant describing the complete dechlorination of TCE at 3.7 years following active bioremediation was approximately 3.6 y–1. Overall, results of this study suggest that biological processes may persist to treat TCE for years after cessation of active bioremediation, thereby serving as an important component of remedial treatment design and long‐term attenuation.  相似文献   

19.
The HydraSleeve is a sampling device for collecting groundwater from the screened interval of a monitoring well without purging that uses a check valve to take in water over the first 3 to 5 feet of an upward pulling motion. If the check valve does not perform as expected, then the HydraSleeve has the potential to collect water from an incorrect depth interval, possibly above the screened interval of the well. We have evaluated volatile organic chemical (VOC) results from groundwater samples collected with the HydraSleeve sampler compared to other methods for sampling monitoring wells at three sites. At all three sites, lower VOC concentration results were observed for samples collected using the HydraSleeve. At two of these three sites, the low concentration sample results were most strongly associated with monitoring wells with more than 10 feet of water above the monitoring well‐screened interval. At the site with the largest dataset, the median bias for samples collected with HydraSleeve was ?20% (p < 0.001). At this site, a bias of ?26% (p < 0.001) was observed for the subset of monitoring wells with greater than 10 feet of water above the screened interval compared to a bias of ?7% (p = 0.21) for wells screened across the top of the water table. In addition to lower VOC concentrations, the monitoring records obtained using the HydraSleeve were more variable compared to monitoring records obtained using purge sampling methods, a characteristic that would make it more difficult to determine the long‐term concentration trend in the well.  相似文献   

20.
Methyl tert -butyl ether (MTBE) and benzene have been measured since 1993 in a shallow, sandy aquifer contaminated by a mid-1980s release of gasoline containing fuel oxygenates. In wells downgradient of the release area, MTBK was detected before benzene, reflecting a chromatographic-like separation of these compounds in the direction of ground water flow. Higher concentrations of MTBE and benzene were measured in the deeper sampling ports of multilevel sampling wells located near the release area, and also up to 10 feet (3 m) below the water table surface in nested wells located farther from the release area. This distribution of higher concentrations at depth is caused by recharge events that deflect originally horizontal ground water flowlines. In the laboratory, microcosms containing aquifer material incubated with uniformly labeled 14C-MTBE under aerobic and anaerobic. Fe(III)-reducing conditions indicated a low but measurable biodegradation potential (<3%14C-MTBW as 14CO2) after a seven-month incubation period, Tert -butyl alcohol (TBA), a proposed microbial-MTBE transformation intermediate, was detected in MTBE-contaminated wells, but TBA was also measured in unsaturated release area sediments. This suggests that TBA may have been present in the original fuel spilled and does not necessarily reflect microbial degradation of MTBE. Combined, these data suggest that milligram per liter to microgram per liter decreases in MTBE concentrations relative to benzene are caused by the natural attenuation processes of dilution and dispersion with less-contaminated ground water in the direction of flow rather than biodegradation at this point source gasoline release site.  相似文献   