首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 156 毫秒
1.
Combined with the existing stochastic lightning parameterization scheme, a classic tripole charge structure in thunderstorms is assumed in the paper, and then 2-dimensional fine-resolution lighting discharge simulations are performed to quantitatively investigate the effect of lower positive charge (LPC) on different types of lightning. The results show: (1) The LPC plays a key role in generating negative cloud-to-ground (CG) flashes and inverted intra-cloud (IC) lightning, and with the increase of charge density or distribution range of LPC region, lightning type changes from positive polarity IC lightning to negative CG flashes and then to inverted IC lightning. (2) Relative to distribution range of charge regions, the magnitude of charge density of the LPC region plays a dominant role in lightning type. Only when the maximal charge density value of LPC region is within a certain range, can negative CG flashes occur, and the occurrence probability is relatively fixed. (3) In this range, the charge density and distribution range of LPC region jointly determine the occurrence of negative CG flashes, which has a linear boundary with the trigger condition of IC lightning. (4) The common effect of charge density and distribution range of the LPC region is to change the distribution of positive potential well of bottom part of thunderstorms, and inverted IC lightning occurs when the initial reference potential is close to 0 MV, and negative CG flashes occur when the initial reference potential is far less than 0 MV.  相似文献   

2.
云闪放电对云内电荷和电位分布影响的数值模拟   总被引:15,自引:3,他引:12       下载免费PDF全文
我们应用改进的随机闪电参数化方案,对两次雷暴的起、放电过程进行了二维125 m和250 m分辨率云闪模拟试验,分析表明高分辨率模拟的云闪通道几何结构、延伸范围和最大垂直电场变化等特征与观测结果更为一致,并且揭示了云闪放电重新配置云内电荷分布和空间电荷中和过程的一种新的物理图像:(1) 云闪的直接物理效应是在已有的空间电荷区内沿着放电通道沉积异极性电荷、形成复杂的空间电荷分布,有效地导致云中电位和场强绝对值及静电场能量剧烈下降,使放电终止.其中:放电后在闪电通道经过主要区域,电位降到±30 MV之间,垂直电场强度也降到±20 kV·m-1之间,一次正或负云闪估计消耗掉107~1010 J静电能;(2) 云中电荷中和不是正、负空间电荷简单地直接相互抵消的瞬态过程,而是广泛分布的云中空间电荷与通道沉积的异极性电荷通过湍流交换、平流输送、重力沉降以及起电等多种因素逐渐混合并部分被中和的一个后续慢过程,其弛豫时间典型值在14~44 s之间,在此期间通道感应电荷总量下降到50%以下.并残余部分电荷参与后续放电前高空间电荷密度和强电场的重建过程.  相似文献   

3.
The comprehensive observations on lightning discharges were conducted in Naqu area of Qinghai-Tibet Plateau in summer of 2002. The electric structures of thunderstorms and the characteristics of lightning discharges at initial stage were analyzed by using the observation data. The results show that most of intracloud (IC) lightning flashes were polarities inverted in thunderstorms with tripole electric charge structure and occurred between negative charge region located in the middle of the thunderstorm and positive charge region located at the bottom of the thunderstorm. The radiation characteristics of discharge processes in cloud with longer lasting time involved in Cloud-to-Ground (CG) lightning flashes were similar to that of IC discharges.A lot of radiation pulses were produced in these discharge processes. Because the IC discharges took place at the bottom of thundercloud and were near the ground, they may produce more serious damage to equipment on the ground therefore should not be neglected in lightning protection.  相似文献   

4.
The comprehensive observations on lightning discharges were conducted in Naqu area of Qinghai-Tibet Plateau in summer of 2002. The electric structures of thunderstorms and the characteristics of lightning discharges at initial stage were analyzed by using the observation data. The results show that most of intracloud (IC) lightning flashes were polarities inverted in thunderstorms with tripole electric charge structure and occurred between negative charge region located in the middle of the thunderstorm and positive charge region located at the bottom of the thunderstorm. The radiation characteristics of discharge processes in cloud with longer lasting time involved in Cloud-to-Ground (CG) lightning flashes were similar to that of IC discharges. A lot of radiation pulses were produced in these discharge processes. Because the IC discharges took place at the bottom of thundercloud and were near the ground, they may produce more serious damage to equipment on the ground therefore should not be neglected in lightning protection.  相似文献   

5.
The upward lightning (UL) initiated from the top of tall buildings (at least above 100 m) is a type of atmospheric discharge. Currently, we understand the nature of the UL from ground observations, but the corresponding theoretical research is lacking. Based on an existing bidirectional leader stochastic model, a stochastic parameterization scheme for the UL has been built and embedded in an existing two-dimensional thundercloud charge/discharge model. The ULs simulated from the experiments with two-dimensional high resolution agree generally with the observation results. By analyzing the charge structure of thunderstorm clouds, we determined the in-cloud environmental characteristics that favor the initiation of conventional cloud-to-ground (CG) flashes and analyzed the differences and similarities of some characteristics of the positive and the negative UL. Simulation results indicate that the positive ULs are typically other-lightning-triggered ULs (OLTUL) and are usually a discharge phenomenon between the ground and the lower positive charge region appearing below the main middle negative charge region. The effect of the previous in-cloud lightning (IC) process of space electrical field provides favorable conditions for the initiation of a positive UL. Its entire discharge process is limited, and the branches of the leader are fewer in number as its discharge is not sufficient. A negative UL is generally a discharge phenomenon of the dipole charge structure between the ground and the main negative charge region. The lower temperature stratification and the sinking of the hydrometeors typically initiate a negative UL. Negative ULs develop strongly and have more branches. The OLTUL is initiated mainly during the development stage of a thunderstorm, while the self-triggered UL (STUL) is initiated mainly during the dissipation stage of a thunderstorm.  相似文献   

6.
随机性与电环境特征对地闪击地点影响的数值模拟   总被引:7,自引:0,他引:7       下载免费PDF全文
本文利用已有的随机放电参数化方案,结合四次探空资料,进行了12.5 m的高分辨率二维雷暴云数值模拟实验,得到了各种雷暴云电荷结构下的地闪个例,并就地闪击地点与空间电荷、电位分布之间的相互关系进行了分析.结果表明:(1)由空间电荷唯一确定的电位分布决定了先导的传播最大趋势,而闪电传播的随机性所带来的地闪击地点的不确定范围被限制在3 km之内,利用动态聚类法迭代得出的三个击地点位置之间的差为1 km左右.(2)负地闪的初始点与击地点的位置差主要分布在0~6 km范围内,且93%的负地闪分布在0~4 km范围内,正地闪的分布相对较广,0~3 km范围内占48%,3~6 km范围内占34%,6~10 km范围内占18%.(3)正、负地闪主要产生于离地面最近的一对电荷堆之间,其起始高度越高,初始点与击地点位置差分布越广;另外,产生于三级性雷暴云电荷结构下的正地闪,其起始于上部的主正电荷堆与中部主负电荷堆之间,由于下行正先导会绕过底部的次正电荷堆,因此其击地点与初始点的距离基本在6 km以上.  相似文献   

7.
The negative CG lightning discharges neutralizing negative charges in cloud usually dominate for most of thunderstorms. However, a lot of positive CG light-ning discharges often occur in the disappearing stage of thunderstorms, in the stratiform region of mesoscale convective systems and some supercells producing hail and tornado. Because the positive CG lightning discharges produce larger current of the return stroke and neutralize more charges due to the continuing currents with longer las…  相似文献   

8.
空中人工引发雷电先导过程的特征分析   总被引:7,自引:3,他引:7       下载免费PDF全文
利用闪电电场变化仪对空中人工引发雷电引起的电场变化进行了两站同步观测,并结合高时间分辨率的光学观测资料的分析研究,揭示了一次空中引发雷电先导物理过程的特征. 当携带金属导线的火箭上升到几百米高度时,在金属导线的上端和下端激发产生了一个双向传输的先导,当向下的负先导接近地面时,一个向上的正连接先导由地面激发,正负先导的平均传播速度为0.86×105m/s,随着向下负先导的接地,将产生一个小回击过程,而由金属导线上端激发的向上正先导的传播速度为1.1×105m/s.  相似文献   

9.
Radio frequency observations of cloud-to-ground lightning (CG) were made in 1999 in Guangdong Province with the broadband lightning interferometer. In this paper, radiation source locations and electric field waveforms are analyzed for different types of breakdown events, including the preliminary breakdown of in-cloud activities, the stepped leaders of initial strokes to ground and activities during and following return strokes. It is shown that the structure and development of lightning discharges and associated breakdown processes can be reconstructed by using this new type of lightning radiation source location system. The detectable radiation of lightning was primarily produced by the negative breakdown process. The channel was concentrated with few branches during the preliminary breakdown stage of CG lightning flashes. The radiation sources appeared generally at the tip of the channel. During the late period of the stepped leader, the radiation sources were dispersed with branches extended away from the main channel. The radiation sources were in a certain length segment of the channel and the altitude of the segment descended along with the propagation of the leader to the ground. During the preliminary breakdown and the stepped leader of initial strokes to the ground, a sequence of fast negative streamers were observed to start continually from or farther away the lightning-initiated region and propagate along the developed leader channel, which may supply negative charge that assisted the leader’s development. The progression speed of fast negative streamers was about ten times faster than the average speed of lightning channel.  相似文献   

10.
青藏高原那曲地区雷电特征初步分析   总被引:32,自引:3,他引:29       下载免费PDF全文
通过对2002年夏季青藏高原那曲地区雷暴过程及闪电观测资料的初步分析,发现该地区雷暴电荷结构具有多样性和复杂性,地闪明显偏少. 对高原地闪的一些基本特征参量的统计分析表明,无论正地闪还是负地闪梯级先导前都具有持续时间较长的云内放电过程,地闪以单次回击为主. 与中低纬度地区相比,高原地闪中正地闪比例明显要高,为33髎;负地闪为67髎;正、负地闪回击后常常伴随短时间的连续电流.  相似文献   

11.
A narrowband radio interferometer has been developed and used to locate the entire sources of VHF radiations from a negative cloud-to-ground (CG) lightning discharge which contains 19 strokes. This system uses five antennas to form an array consisting of short- and long-baselines along two or- thogonal directions. The system error which comes from frequency conversion is reduced by phase detection through direct high frequency amplifying. An interactive graphic analysis procedure is used to remove the fringe ambiguities which exist inherently in interferometry and to determine the direction of lightning radiation sources in two dimensions (azimuth and elevation) as a function of time at a time resolution of microsecond orders. With the developed system, the whole progression process in time and space of a lightning flash can be reconstructed. In this paper, combining the synchronous data of electric filed change and VHF radiation, the whole processes of an example negative CG flash have been studied in detail. It is found that the preliminary breakdown event of the CG flash started from negative charge region and exhibited firstly a downward pregression and then an upward propagation. There were very intense and continuous radiations during stepped leaders which became much stronger when the first return stroke began. In contrast, there were less and only discrete radiations during dart leaders. Stepped leader and dart leader may transform to each other depending on the state of the ionization of the path. The progression speed of initial stepped leaders was about 105 ms?1, while that was about 4.1×106 and 6.0×106 ms?1 for dart leaders and dart-stepped leaders, respectively. M events produced hook-shaped field changes accompanied by active burst of radiations at their begin- nings. Followed these active radiation processes, M events appeared to contact finally into conducting main discharge channels. The mean progression speed of M events was about 7×107 ms?1, greater than that of the dart leaders and dart-step leaders. K events and attempted leaders were essentially the same as dart leaders except that they could not reach the ground and initiate return strokes.  相似文献   

12.
Summary Although lightning flashes have been photographed which apparently have up to 40 or more component strokes, no flashes having more than 14 strokes have been observed on records of the eletrical fields of thunderstorms. The apparent discrepancy between the two methods of observation is explained by the fact that small momentary increases in the continuing current flowing to ground after some strokes, are easily mistaken for component strokes on photographs taken with slow cameras.After the cessation of a discharge, the ionization of the lightning channel decreases at such a rate that a subsequent discharge to earth will require a fresh leader if it follows within an interval longer than about 15 millisec; discharges following at shorter intervals are not preceded by leaders. The channel loses its ionization completely in about 100 millisec.In general, the larger the number of component strokes, the longer is the duration of the flash, but there is no definite relationship between the number of strokes and the duration.Flashes of exceptionally long duration always have one or more very long intervals between two successive strokes and during these intervals there appears to be very little electrical activity in the cloud; it is suggested that the main progress of the discharge in the cloud takes place during the shorter intervals, so that flashes of long duration do not necessarily drain very extensive regions of charge.I wish to thank the South African Council for Scientific and Industrial Research for a grant in aid of this research.  相似文献   

13.
对观测资料的分析表明,甘肃地区和海南岛的地闪特征具有很大差异。海南岛负地闪(P型)首次回击前的电场变化波形与国外的报道类似,而甘肃地区仅有30%左右的负地闪属P型,约70%的负地闪首次回击前的电场变化波形具有明显的云闪特征(C型负地闪)。海南岛没有发现正地闪,甘肃地区有正地闪。该两地区存在两类电结构不同的雷暴,两类雷暴中地闪放电过程及特征的很大差异,说明我国的防雷规范及措施很可能需要考虑雷暴的地区差异性。  相似文献   

14.
The purpose of this study was to understand the reasons why frequent positive cloud-to-ground (+CG) flashes occur in severe thunderstorms. A three-dimensional dynamics-electrification coupled model was used to simulate a severe thunderstorm to permit analysis of the conditions that might easily cause +CG flashes. The results showed that strong updrafts play an important role in the occurrence of intracloud flashes. However, frequent +CG flashes require not only strong updrafts but also strong downdrafts in the lower cloud region, conditions that correspond to the later phase of the mature stage and the period of the heaviest solid precipitation of a thunderstorm. During this stage, strong updrafts elevated each charge area in the updraft region to a higher level, which resulted in an inverted tripole charge structure. A wide mid-level region of strong positive charge caused largely by positively charged graupel, presented in the middle of the updraft region because of a non-inductive ice-ice collisional charging mechanism. The charge structure in the downdraft region was consistently more complex and revealed several vertically stacked charge regions, alternating in polarity. Much of the graupel/hail outside the updrafts was lowered to cloud-base by strong downdrafts. In this area, the graupel/hail was charged negatively because of the transportation of negatively charged graupel/hail from higher regions of negative charge in the updrafts, and via the inductive charging mechanism of collisions between graupel/hail and cloud droplets at the bottom of the cloud. Consequently, a large region of negative charge formed near the ground. This meant that +CG flashes were initiated more easily in the lower inverted dipole, i.e., the middle region of positive charge and lower region of negative charge. Frequent +CG flashes began almost synchronously with dramatic increases in the storm updrafts, hail volume, and total flash rate. Therefore, the occurrence of +CG flashes appears a good indicator of storm intensification and it could have some use as a predictor of severe weather in the form of hail.  相似文献   

15.
The characteristics (annual and diurnal cycle, polarity, multiplicity and first stroke peak current) of ∼4.3×106 cloud-to-ground flashes recorded in the Iberian Peninsula during the first decade of measurements of the lightning detection network installed in Spain are analyzed. The mean monthly variation shows maximum lightning activity between May and September, while minimum values are observed in January and February. The mean diurnal cycle shows maximum values at 1700 LT and minimum values at around 1000 LT. The average maximum flash density (not corrected for detection efficiency) is 2.1 flashes km−2 year−1. Maximum lightning activity is associated with mountainous areas. The effect of the Mediterranean Sea is also seen. The percentage of positive flashes is 9%, although this changes over the year from 6.5% in June to 22.6% in January. The average multiplicity is found to be 2.0 for the negative flashes and 1.1 for the positive flashes, and the percentages of single-stroke flashes are 53.6% and 89%, respectively. The monthly distribution of multiplicity for negative flashes peaks in the summer and minimum values are found in the winter. The multiplicity of the positive flashes does not seem to be function of the month. The median (mean) first stroke peak currents are found to be 23.5 kA (27.3 kA) for the negative flashes and 35.3 kA (47.1 kA) for the positive flashes. For both polarities, the peak current is higher in the summer than in the winter. The percentage of positive flashes and the mean peak currents for negative flashes are higher over the sea areas than over land.  相似文献   

16.
Using the optical images of a cloud-to-ground lightning flash with multiple grounding points obtained by a highspeed video system in the Qinghai Province of China along with synchronous radiated electric field information, the propagation characteristic and the electric field change features of the leaders and the grounding behavior of discharge channels are analyzed.In addition, the two-dimensional velocity of the leader was estimated and its correlation with the time interval of the corresponding subsequent return stroke, and that with the peak current of return stroke are investigated. The results show that the average distance between the three obvious grounded points of the first return stroke channel is about 512.7 m, and the average time interval between the pulses of the corresponding electric field fast changes is 3.8 μs. Further, the average time interval between electric field pulses from the stepped leader is smaller than that of normal single grounding lightning. The observed lightning in our study has two main channels, namely the left and right channels. Based on our observations, it is clear that the dart leader comes close to the ground in case of the left channel after the first return stroke, but it fails to form a return stroke.However, the right channel exhibits a relatively rare phenomenon in that the subsequent return stroke R2 occurred about 2.1 ms after the dart leader arrived at the ground, which was unusually long; this phenomenon might be attributed to the strong discharge of the first return stroke and insufficient charge accumulation near the grounded point in a timely manner. The two-dimensional velocities for the stepped leader of the two main channels are about 1.23×105 and 1.16×105 m s-1, respectively. A sub-branch of stepped leader for the left channel fails to reach the ground and develops into an attempt leader eventually; this might be attributed to the fact that the main branch connects considerably many sub-branches, which leads to the instantaneous decline of the potential difference between the sub-branch and ground. Furthermore, it might also be because the propagation direction of this sub-branch is almost perpendicular to the atmospheric electric field direction, which is not conducive to charge transfer. The two-dimensional velocities for the dart leaders of five subsequent return strokes are all in the normal range, and they positively correlate with the peak current of the subsequent return stroke.  相似文献   

17.
Based on the Weather Research Forecasting (WRF) model that features charging and discharging parameterization, relationships between tornado, hail and lightning were investigated for a tornado-producing (EF4 intensity) supercell thunderstorm over Yancheng City in Jiangsu Province, China, on 23 June 2016. Based on a sounding at 0800, there was a low lifting condensation level, substantial convective available potential energy (CAPE), and strong vertical wind shear near Yancheng City, which promote supercell development. At 1400, observations revealed that hail production and a dramatic increase of positive cloud-to-ground flash rates occurred simultaneously, maximizing five minutes later. The tornado occurred 30 min after the hail production. The time of minimum positive cloud-to-ground flash rates was 15 min later. The simulation indicated that the tornadic supercell moved eastward and that positive cloud-to-ground flash rates increased dramatically at 1400, the same as observed, but their maximum was 5 min later than observed. The simulated updraft volume peaked at 1425 and the simulated downdraft volume maximized 5 min later, when the mesocyclone formed. Simulated reflectivities showed no hook echo and horizontal winds for different height at mid-low levels had a different cyclonic shear at 1430, favorable to mesocyclone formation. Based on the simulated results, the region of positively charged graupel ascended resulting from the region of high liquid water content was lifted by the strong updraft, forming a mid-level strong positive charge region. A lower negative charge region formed by the inductive charging mechanism of collisions between graupel and droplets at the bottom of the cloud, conducive to positive cloud-to-ground flashes.  相似文献   

18.
A time-of-arrival(TOA) system based on GPS technology for locating VHF radiation sources from lightning has been developed and used in observation sites in the northern Shandong Province,China.The 3D images of the lightning progression have been obtained successfully for the first time in China.The 3D-channel evolutions of typical negative CG,positive CG and IC lightning flashes have been discussed together with the data of fast electric field change.It was found that significant differences existed between the negative and positive CG lightning flashes in terms of the initiation and propagation of the radiation sources.The preliminary breakdown of a negative CG lightning flash propagated at a speed about 5.2×104 m/s.The stepped leader of negative CG lightning flashes was trigged by negative initial breakdown.Thereafter,it propagated downward at a speed of 1.3×105 m/s.The initial process of the positive CG lightning flashes was also a propagation process of negative streamer.These streamers propagated dominantly horizontally in the positive charge region and accumulated positive charges at the origin of the lightning,and as a consequence,initiated downward positive streamers.A new type of lightning discharge that was triggered by a narrow bipolar pulse(NBP) is discussed in this study.The NBP was originated at altitude of about 10.5 km in the upper positive charge region.As a distinct difference from normal IC flash,its channels extended horizontally all around and produced a lot of radiation sources.The source power of the NBP could approach 16.7 kW,which is much greater than that of normal lightning discharge ranging between 100 mW and 500 W.The 3D propagation of this new type of lightning discharge was observed and obtained for the first time in China.The possible initiation mechanism of this new type of light-ning is discussed here.  相似文献   

19.
This paper presents direct measurements of narrowband 10 MHz HF radiation from so-called “chaotic leaders” associated with subsequent return strokes. Although the term is controversial and poorly defined, we find that more than 30% of subsequent strokes in close lightning flashes contain electric field characteristics that are best described as “chaotic”. In earlier studies, return strokes have consistently been observed to be the strongest sources of HF radiation, but the results for leader processes are less consistent. We also observe return strokes to be the main HF emitter, and the leaders before the first return stroke in a flash sequence also emit HF though somewhat less intensely. The leaders preceding subsequent strokes typically emit little or no HF radiation, whether they are dart or dart-stepped leaders.However, it was observed that the presence of a chaotic component increases the leader HF intensity dramatically Defining the HF intensity unequivocally can be problematic for processes like chaotic leaders which have a combination of continuous and impulsive phenomena. Two time-domain methods were used to measure the HF intensity, the peak energy and the RMS energy. In the frequency domain these correspond to the energy spectral density (ESD) and power spectral density (PSD), respectively.It was found that the methods are not necessarily compatible. Thus, it is suggested that to clarify future work, leader processes should be characterized by the PSD rather than the ESD.  相似文献   

20.
Since the summer of 1996, scientists from China and Japan have conducted a joint observation of natural cloud-to-ground lightning discharges in the Zhongchuan area that is located close to Qinghai-Xizang (Tibet) Plateau, China. It has been found that the long-duration of intracloud discharge processes, just before the first return stroke, lasted more than 120 ms for 85% of cloud-to-ground flashes in this area, with a mean duration of 189.7 ms and a maximum of 300 ms. We present the results of charge sources neutralized by four ground flashes and two intracloud discharge processes, just before the first return stroke, by using the data from a 5-site slow antenna network synchronized by GPS with 1 s time resolution. The result shows that the altitudes of the neutralized negative charge for three negative ground flashes were between 2.7 to 5.4 km above the ground, while that of neutralized positive charges for one positive ground flash and one continuing current process were at about 2.0 km above the ground. The comparison with radar echo showed that the negative discharges initiated in the region greater than 20 dBZ or near the edge of the region with intense echoes greater than 40 dBZ, while positive discharge initiated in the weak echo region.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号