首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 375 毫秒
1.
This paper investigates the response of asymmetric‐plan buildings with supplemental viscous damping to harmonic ground motion using modal analysis techniques. It is shown that most modal parameters, except dynamic amplification factors (DAFs), are affected very little by the plan‐wise distribution of supplemental damping in the practical range of system parameters. Plan‐wise distribution of supplemental damping significantly influences the DAFs, which, in turn, influence the modal deformations. These trends are directly related to the apparent modal damping ratios; the first modal damping ratio increases while the second decreases as CSD moves from right to left of the system plan, and their values increase with larger plan‐wise spread of the supplemental damping. The largest reduction in the flexible edge deformation occurs when damping in the first mode is maximized by distributing the supplemental damping such that the damping eccentricity takes on the largest value with algebraic sign opposite to the structural eccentricity. Copyright © 2000 John Wiley & Sons, Ltd.  相似文献   

2.
This paper investigates the effects of supplemental viscous damping on the seismic response of one‐storey, asymmetric‐plan systems responding in the inelastic range of behaviour. It was found that addition of the supplemental damping reduces not only deformation demand but also ductility and hysteretic energy dissipation demands on lateral load resisting elements during earthquake loading. However, the level of reduction strongly depends on the plan‐wise distribution of supplemental damping. Nearly optimal reduction in demands on the outermost flexible‐side element, an element generally considered to be the most critical element, was realized when damping was distributed unevenly in the system plan such that the damping eccentricity was equal in magnitude but opposite in algebraic sign to the structural eccentricity of the system. These results are similar to those noted previously for linear elastic systems, indicating that supplemental damping is also effective for systems expected to respond in the inelastic range. Copyright © 2001 John Wiley & Sons, Ltd.  相似文献   

3.
This study investigated the effects of neglecting off‐diagonal terms of the transformed damping matrix on the seismic response of non‐proportionally damped asymmetric‐plan systems with the specific aim of identifying the range of system parameters for which this simplification can be used without introducing significant errors in the response. For this purpose, a procedure is presented in which modal damping ratios computed by neglecting off‐diagonal terms of the transformed damping matrix are used in the traditional modal analysis. The effects of the simplification are evaluated first by comparing the aforementioned modal damping ratios with the apparent damping ratios obtained from the complex‐valued eigenanalysis. The variation of a parameter that was defined by Warburton and Soni as an indicator of the errors introduced by the simplification is examined next. Finally, edge deformations obtained from the simplified procedure are compared with those obtained from the direct integration of the equations of motion. It is found that the simplified procedure may be used without introducing significant errors in response for most practical values of the system parameters. Furthermore, estimates of the edge deformations, in general, tend to be on the conservative side. Copyright © 2001 John Wiley & Sons, Ltd.  相似文献   

4.
Investigated is the accuracy in estimating the response of asymmetric one‐storey systems with non‐linear viscoelastic (VE) dampers by analysing the corresponding linear viscous system wherein all non‐linear VE dampers are replaced by their energy‐equivalent linear viscous dampers. The response of the corresponding linear viscous system is determined by response history analysis (RHA) and by response spectrum analysis (RSA) extended for non‐classically damped systems. The flexible and stiff edge deformations and plan rotation of the corresponding linear viscous system determined by the extended RSA procedure is shown to be sufficiently accurate for design applications with errors generally between 10 and 20%. Although similar accuracy is also shown for the ‘pseudo‐velocity’ of non‐linear VE dampers, the peak force of the non‐linear VE damper cannot be estimated directly from the peak damper force of the corresponding linear viscous system. A simple correction for damper force is proposed and shown to be accurate (with errors not exceeding 15%). For practical applications, an iterative linear analysis procedure is developed for determining the amplitude‐ and frequency‐dependent supplemental damping properties of the corresponding linear viscous system and for estimating the response of asymmetric one‐storey systems with non‐linear VE dampers from the earthquake design (or response) spectrum. Finally, a procedure is developed for designing non‐linear supplemental damping systems that satisfy given design criteria for a given design spectrum. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

5.
Design formulas for supplemental viscous dampers to building structures are readily available in FEMA provisions and MCEER research reports. However, for the design of supplemental viscous dampers corresponding to a desired system damping ratio of highway bridges, there exist, if any, few design guidelines. This is particularly true if the bridge components such as elastomeric bearings, piers and abutment possess different damping ratios, stiffnesses, and lumped masses. In this paper, the design formulas for supplemental viscous dampers to highway bridges have been derived based on the concept of ‘composite damping ratio’. The design formulas can be used to determine the damping coefficients of the dampers corresponding to a desired system damping ratio of the bridge in which different component damping ratios may be assumed for the elastomeric bearings, piers and abutments. The proposed design formulas are numerically validated by comparing the seismic responses of a three‐span bridge equipped with viscous dampers with those of the same bridge without viscous dampers but with an assigned inherent system damping ratio equal to the target system damping ratio. Copyright © 2005 John Wiley & Sons, Ltd.  相似文献   

6.
A new direct performance‐based design method utilizing design tools called performance‐spectra (P‐Spectra) for low‐rise to medium‐rise frame structures incorporating supplemental damping devices is presented. P‐Spectra are graphic tools that relate the responses of nonlinear SDOF systems with supplemental dampers to various damping parameters and dynamic system properties that structural designers can control. These tools integrate multiple response quantities that are important to the performance of a structure into a single compact graphical format to facilitate direct comparison of different potential solutions that satisfy a set of predetermined performance objectives under various levels of seismic hazard. An SDOF to MDOF transformation procedure that defines the required supplemental damping properties for the MDOF structure to achieve the response defined by the target SDOF system is also presented for hysteretic, linear viscous and viscoelastic damping devices. Using nonlinear time‐history analyses of idealized shear structures, the accuracy of the transformation procedure is verified. A seismic performance upgrade design example is presented to demonstrate the usefulness of the proposed method for achieving design performance goals using supplemental damping devices. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

7.
Supplemental damping could mitigate the earthquake‐induced damage in buildings with asymmetric plan, known to be more vulnerable to damage than comparable symmetric‐plan buildings. This investigation aims to improve the understanding of how and why planwise distribution of fluid viscous dampers (FVDs) influences the response of linearly elastic, one‐storey, asymmetric‐plan systems. Starting with vibration mode shapes, we predict this influence on the modal damping ratios, and in turn on the individual modal responses and the total response. These predictions are confirmed by the computed responses, which demonstrated that the reduction in earthquake response of the system achieved by supplemental damping is strongly influenced by its planwise distribution, which is characterized by four parameters. Identified are asymmetric distributions of supplemental damping that are more effective in reducing the response compared to symmetric distribution. The percentage reduction achieved by a judiciously selected asymmetric distribution can be twice or even larger compared to symmetric distribution. Copyright © 2001 John Wiley & Sons, Ltd.  相似文献   

8.
Numerical simulations are performed to assess the effects of near-fault ground motions on base-isolated buildings that consist of either lead-rubber (LRB) or friction-pendulum system (FPS) bearings in addition to supplemented viscous dampers. While LRB and FPS isolation systems have been applied for a number of years, the addition of supplemental damping devices is being currently considered for strong ground motions to reduce the isolator displacements. However, the main problem in this case is that the addition of damping may increase both internal deformation and absolute accelerations of the superstructure and thus may defeat many of the gains for which base isolation is intended. In the present paper, a detailed and systematic investigation on the performance of LRB and FPS isolation systems, provided with supplemental viscous damping under the effect of near-fault ground motions, has been carried out by using commercial finite element software.  相似文献   

9.
Understanding the trends in torsional effects in asymmetric-plan buildings   总被引:1,自引:1,他引:0  
This paper studied the reasons behind the four trends in torsional effects in asymmetric-plan buildings observed in the current literature. It was found that the modal eccentricities and the non-proportionality between the modal translations and the modal rotation are key to understanding these trends in torsional effects in asymmetric-plan buildings. These key points were obtained from the three-degree-of-freedom modal systems, which represent the single vibration mode of a two-way asymmetric-plan building. This paper showed that the modal eccentricities, rather than the overall structural eccentricities, are the critical parameters for deciding the trend of the unequal displacement demand on the floor diaphragm. In addition, the non-proportionality between the modal translations and the modal rotation leads to the trend that the torsional effects generally decrease when plastic deformations increase.  相似文献   

10.
Investigated are earthquake responses of one‐way symmetric‐plan, one‐storey systems with non‐linear fluid viscous dampers (FVDs) attached in series to a linear brace (i.e. Chevron or inverted V‐shape braces).Thus, the non‐linear damper is viscous when the brace is considered rigid or viscoelastic (VE) when the brace is flexible. The energy dissipation capacity of a non‐linear FVD is characterized by an amplitude‐dependent damping ratio for an energy‐equivalent linear FVD, which is determined assuming the damper undergoes harmonic motion. Although this formulation is shown to be advantageous for single‐degree‐of‐freedom (SDF) systems, it is difficult to extend its application to multi‐degree‐of‐freedom (MDF) systems for two reasons: (1) the assumption that dampers undergo harmonic motion in parameterizing the non‐linear damper is not valid for its earthquake‐induced motion of an MDF system; and (2) ensuring simultaneous convergence of all unknown amplitudes of dampers is difficult in an iterative solution of the non‐linear system. To date, these limitations have precluded the parametric study of the dynamics of MDF systems with non‐linear viscous or VE dampers. However, they are overcome in this investigation using concepts of modal analysis because the system is weakly non‐linear due to supplemental damping. It is found that structural response is only weakly affected by damper non‐linearity and is increased by a small amount due to bracing flexibility. Thus, the effectiveness of supplemental damping in reducing structural responses and its dependence on the planwise distribution of non‐linear VE dampers were found to be similar to that of linear FVDs documented elsewhere. As expected, non‐linear viscous and VE dampers achieve essentially the same reduction in response but with much smaller damper force compared to linear dampers. Finally, the findings in this investigation indicate that the earthquake response of the asymmetric systems with non‐linear viscous or VE dampers can be estimated with sufficient accuracy for design applications by analysing the same asymmetric systems with all non‐linear dampers replaced by energy‐equivalent linear viscous dampers. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

11.
Viscous and other damping devices are often used as elements of seismic isolation systems. Despite the widespread application of nonlinear viscous systems particularly in Japan (with fewer applications in the USA and Taiwan), the application of viscous damping devices in isolation systems in the USA progressed intentionally toward the use of supplementary linear viscous devices due to the advantages offered by these devices. This paper presents experimental results on the behavior of seismically isolated structures with low damping elastomeric (LDE) and single friction pendulum (SFP) bearings with and without linear and nonlinear viscous dampers. The isolation systems are tested within a six‐story structure configured as moment frame and then again as braced frame. Emphasis is placed both on the acquisition of data related to the structural system (drifts, story shear forces, and isolator displacements) and on non‐structural systems (floor accelerations, floor spectral accelerations, and floor velocities). Moreover, the accuracy of analytical prediction of response is investigated based on the results of a total of 227 experiments, using 14 historic ground motions of far‐fault and near‐fault characteristics, on flexible moment frame and stiff braced frame structures isolated with LDE or SFP bearings and linear or nonlinear viscous dampers. It is concluded that when damping is needed to reduce displacement demands in the isolation system, linear viscous damping results in the least detrimental effect on the isolated structure. Moreover, the study concludes that the analytical prediction of peak floor accelerations and floor response spectra may contain errors that need to be considered when designing secondary systems. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

12.
During severe seismic events, structures designed according to current standards yield and develop inelastic deformations. While the acceleration responses are limited by the yielding strength, these structures develop permanent deformations (and possible damage) due to such yielding. Spectra developed for inelastic structures can help in determining the desired yield levels and the associated inelastic deformations. Some structures made of special materials or equipped with innovative structural systems may yield, but can recover the deformation upon unloading and, thus, may avoid permanent deformations. These structures are known as nonlinear elastic. Often the post yielding excursions are very large and may exceed their toughness (or deformability). By introducing damping in form of supplemental devices, it is possible to control such deformations and keep them within acceptable limits. Spectra for such nonlinear elastic structures and inelastic structures are developed herein, by considering both inherent and supplemental damping. The difference between the two types of damping is addressed both theoretically and numerically. Design examples of several simple structures using the newly developed spectra are presented, which illustrate the importance of lower strength and damping in these nonlinear elastic or inelastic systems. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

13.
附加或不附加粘滞阻尼墙的RC框架试验与分析   总被引:1,自引:0,他引:1  
本文阐述了附加或不附加粘滞阻尼墙的2个相同的RC框架模型振动台试验和理论分析的情况.这2个钢筋混凝土框架模型为3层1跨两开间,几何相似关系大致为1:2.将阻尼墙附加到一个RC框架模型当中,先后对附加或不附加阻尼墙的2个相同的RC框架模型进行振动台试验.试验结果表明,阻尼墙有效减小了框架模型的地震反应.对耗能框架模型和普通框架模型进行了弹性和弹塑性时程分析,计算结果和试验结果吻合良好.改变阻尼墙的参数进行分析,结果表明选取合适的阻尼墙参数,才能达到最好的耗能减振效果;适当减小层间位移较小处的阻尼墙参数,对减振效果影响很小而又能节省投资.  相似文献   

14.
This paper proposes a method for the estimation of the seismic energy demands of two-way asymmetric-plan buildings under bi-directional ground excitations. The modal absorbed energies of asymmetric-plan buildings are estimated by using the three-degree-of-freedom (3DOF) modal systems. The 3DOF modal system represents the two roof translations versus the two base shears and the roof rotation versus the base torque relationships of each vibration mode of two-way asymmetric-plan buildings. Not only the total absorbed energy but also the portions of the total absorbed energy contributed from translational and rotational deformations can be respectively estimated. This study verifies the relationship between the signs of modal eccentricities and the trend of uneven distribution of modal absorbed energy on floor-plan edges of asymmetric-plan buildings. The accuracy of the proposed method was verified by analyzing one 3-storey and one 20-storey two-way asymmetric-plan buildings subjected to bi-directional ground motions. The computational efficiency of the proposed method is confirmed by comparing the computation time with that required by using the nonlinear response history analysis.  相似文献   

15.
Uneven distribution of seismic demand in asymmetric-plan structures is a critical concern in earthquake-resistant design. Contemporary seismic design strategies that are based on linear elastic response, single load reduction factor, and uniform ductility demand throughout an asymmetric system generally lead to unsatisfactory performance in terms of realized ductilities and nonuniform damage distribution due to strong torsional coupling associated with asymmetric-plan systems. In many cases, actual nonlinear behavior of the structure displays significant deviation from what is estimated by a linear elastic, force-based seismic design approach. This study investigates the prediction of seismic demand distribution among structural members of a single-story, torsionally stiff asymmetric-plan system. The focus is on the effect of inherent unbalanced overstrength, resulting from current force-based design practices, on the seismic response of code-designed single-story asymmetric structures. The results obtained are utilized to compile unsymmetrical response spectra and uniform ductility spectra, which are proposed as assessment and preliminary design tools for estimating the seismic performance of multistory asymmetric structures. A simple design strategy is further suggested for improving the inelastic torsional performance of asymmetric systems. Providing additional strength to stiff edge members over their nominal design strength demands leads to a more balanced ductility distribution. Finally, seismic responses of several asymmetric case study structures designed with the aid of the proposed strategy are assessed for validating their improved performance.  相似文献   

16.
The inelastic response of one-storey, asymmetric-plan systems to two excitations is presented and analysed with the objective of identifying the influence of system parameters: uncoupled lateral vibration period, uncoupled torsional-to-lateral frequency ratio, stiffness eccentricity, relative values of the strength and stiffness eccentricities, and yield factor. Furthermore, the influence of yielding on the response of asymmetric-plan systems is examined. In particular, we determine whether the well known relationship between the response of yielding and elastic single-degree-of-freedom (SDF) systems is also applicable to asymmetric-plan systems.  相似文献   

17.
18.
The insertion of fluid viscous dampers in building structures is an innovative technology that can improve significantly the seismic response. These devices could be very useful also in the retrofit of existing buildings. The effect of this typology of damping system is usually identified with an equivalent supplemental damping ratio, which depends on the maximum displacement of the structure, so that iterative procedures are required. In this paper, a simplified direct assessment method for nonlinear structures equipped with nonlinear fluid viscous dampers is proposed. The method proposed in this study is composed by two steps. The first one yields the direct estimate of the supplemental damping ratio provided by nonlinear viscous dampers in presence of a linear elastic structural response. The second step extends the procedure to structures with nonlinear behavior. Both graphical and analytical approaches have been developed. The proposed method has then been verified through several applications and comparisons with nonlinear dynamic analyses. Moreover, an investigation has been performed with regard to the influence of the relations that define the damping reduction factor and the hysteretic damping. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

19.
The development and applications of a supplemental viscous damping device with active capacity are described. The system of the dampers defined as active viscous damping system (AVDS) is presented herein. Structural control principles defined here as active control theory (ACT) are used to obtain the control forces at each time step during an excitation. Control of the damping forces is possible due to a mechanical structure of the proposed AVDS and do not require the input of large power and energy. This system can be efficiently used to enhance the damping of a structure without adding in stiffness and strength. The added damping forces can be adjusted in a wide range. Its efficiency is demonstrated by a numerical simulation of a seven‐storey building subjected to earthquakes. The simulation shows that the behaviour of the damped structure with the AVDS is significantly improved compared to that of an uncontrolled system. Moreover, the response is better than that of adding either passive viscous dampers or electrorheological damping devices. Copyright © 2001 John Wiley & Sons, Ltd.  相似文献   

20.
The steady‐forced and earthquake responses of SDF systems with a non‐linear fluid viscous damper (FVD) are investigated. The energy dissipation capacity of the FVD is characterized by the supplemental damping ratio ζsd and its non‐linearity by a parameter designated α. It is found that the structural response is most effectively investigated in terms of ζsd and α because (1) these two parameters are dimensionless and independent, and (2) the structural response varies linearly with the excitation intensity. Damper non‐linearity has essentially no influence on the peak response of systems in the velocity‐sensitive spectral region, but differences up to 14% were observed in the other spectral regions. The structural deformation is reduced by up to 25% when ζsd= 5%; and by up to 60% when ζsd= 30%. Non‐linear FVDs are advantageous because they achieve essentially the same reduction in system responses but with a significantly reduced damper force. For practical applications, a procedure is presented to estimate the design values of structural deformation and forces for a system with non‐linear FVD directly from the design spectrum. It is demonstrated that the earthquake‐induced force in a non‐linear FVD can be estimated from the damper force in a corresponding system with linear FVD, its peak deformation, and peak relative velocity; however, the relative velocity should not be approximated by the pseudo‐velocity as this approximation introduces a large error in the damper force. Finally, a procedure is presented to determine the non‐linear damper properties necessary to limit the structural deformation to some design value or the structural capacity for a given design spectrum. Copyright © 2002 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏