首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The Friction Pendulum System (FPS) isolator is commonly used as a base isolation system in buildings. In this paper, a new tunable FPS (TFPS) isolator is proposed and developed to act as a semi‐active control system by combining the traditional FPS and semi‐active control concept. Theoretical analysis and physical tests were carried out to investigate the behavior of the proposed TFPS isolator. The experimental and theoretical results were in good agreement, both suggesting that the friction force of the TFPS isolator can be tuned to achieve seismic isolation of the structure. A series of numerical simulations of a base‐isolated structure equipped with the proposed TFPS isolator and subjected to earthquake ground motions were also conducted. In the analyses, the linear quadratic regulator (LQR) method was adopted to control the friction force of the proposed TFPS, and the applicability and effectiveness of the TFPS in controlling the structure's seismic responses were investigated. The simulation results showed that the TFPS can reduce the displacement of the isolation layer without significantly increasing the floor acceleration and inter‐story displacement of the superstructure, confirming that the TFPS can effectively control a base‐isolated structure under earthquake ground motions.  相似文献   

2.
This paper presents a detailed study on feasibility of un‐bonded fiber reinforced elastomeric isolator (U‐FREI) as an alternative to steel reinforced elastomeric isolator (SREI) for seismic isolation of un‐reinforced masonry buildings. Un‐reinforced masonry buildings are inherently vulnerable under seismic excitation, and U‐FREIs are used for seismic isolation of such buildings in the present study. Shake table testing of a base isolated two storey un‐reinforced masonry building model subjected to four prescribed input excitations is carried out to ascertain its effectiveness in controlling seismic response. To compare the performance of U‐FREI, same building is placed directly on the shake table without isolator, and fixed base (FB) condition is simulated by restraining the base of the building with the shake table. Dynamic response characteristic of base isolated (BI) masonry building subjected to different intensities of input earthquakes is compared with the response of the same building without base isolation system. Acceleration response amplification and peak response values of test model with and without base isolation system are compared for different intensities of table acceleration. Distribution of shear forces and moment along the height of the structure and response time histories indicates significant reduction of dynamic responses of the structure with U‐FREI system. This study clearly demonstrates the improved seismic performance of un‐reinforced masonry building model supported on U‐FREIs under the action of considered ground motions. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

3.
张立维 《地震工程学报》2019,41(6):1637-1642
高层建筑物在地震作用下易出现倒塌状况,严重影响人身安全,因此高层建筑物地震安全防护距离的预测至关重要。设计以基础数据库为核心的高层建筑物地震安全防护距离预测系统,通过高层建筑物基本信息系统采集高层建筑物高度、宽度、结构类型等基本数据信息,并将这些信息存储到震害数据库系统中;地震危害模型分析系统依据数据库系统中存储的这些建筑物基本信息,分析地震危险性后,通过研究地震时高层建筑上部结构水平、底部及顶部先接触地面三种落地状态情况下,计算得到薄弱层和薄弱层上部结构高度的安全防护距离。实验验证在人工地震波作用下,利用该预测系统可有效获取实验小区高层建筑物的安全防护距离界定示意图,且其能够准确分析地震作用下高层建筑物晃动时"飞石"安全距离,以及三种地震波作用下建筑物地震安全防护距离分布规律和主要影响范围,其预测效果好。  相似文献   

4.
李然 《地震工程学报》2018,40(5):891-896
隔震器与填充墙对建筑抗震性能有很大作用。为了探究填充墙布置形式及填充材料和隔震器协同作用对钢筋混凝土框架结构动力特性及抗震性能的影响,采用等效斜撑理论,对3种不同填充墙布置形式与隔震器协同作用的抗震系统方案进行对比分析,研究发现顶层不布置填充墙与隔震器协同抗震系统钢筋混凝土框架结构的抗震性能最佳。在此系统上分析了不同填充材料对钢筋混凝土框架结构抗震性能的影响,结果表明,加气混凝土砌块填充墙的钢筋混凝土框架结构抗震性能最好。  相似文献   

5.
6.
The ability of a recently proposed seismic isolation system, with inherent self‐stopping mechanism, to mitigate or even eliminate seismic pounding of adjacent structures is investigated under severe near‐fault earthquakes. The isolation system is referred to as roll‐in‐cage (RNC) isolator. It is a rolling‐based isolator that provides in one unit the necessary functions of vertical rigid support, horizontal flexibility with enhanced stability, hysteretic energy dissipation, and resistance to minor vibration loads. In addition, the RNC isolator is distinguished by a self‐stopping (buffer) mechanism to limit the bearing displacement under excitations stronger than a design earthquake or at limited seismic gaps, and a linear gravity‐based self‐recentering mechanism to prevent permanent bearing displacement without causing vertical fluctuation of the isolated structure. A previously developed multifeature SAP2000 model of the RNC isolator is improved in this paper to account for the inherent buffer mechanism's damping. Then, the effectiveness of the isolator's buffer mechanism in limiting peak bearing displacements is studied together with its possibly arising negative influence on the isolation efficiency. After that, the study investigates how to alleviate or even eliminate those possibly arising drawbacks, due to the developed RNC isolator's inner pounding as a result of its buffer activation, to achieve efficient seismic isolation with no direct structure‐to‐structure pounding, considering limited seismic gaps with adjacent structures and near‐fault earthquakes. The results show that the RNC isolator could be an efficient solution for aseismic design in near‐fault zones considering limited seismic gaps. Earthquake Engineering and Structural Dynamics. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

7.
基础隔震技术广泛应用于建筑结构以减轻结构的地震响应.值得注意的是,在隔震体系中减小主结构的加速度响应是以牺牲隔震器变形为代价的.调谐惯容系统(TID)和隔震器组成的混合隔震体系可减小隔震层的位移响应.与传统调谐质量阻尼器(TMD)结构类似,TID 由惯容、调谐弹簧和阻尼元件组成.因此,可直接利用 TMD减震系统的设计公式来确定 TID 的最优参数.首先基于单自由度体系(SDOF)附加 TID的运动方程,推导分析两种 TID和 TMD设计公式,对两者设计公式的前提条件和适用性进行深入的探讨.其后,借助基础隔震体系的benchmark模型来检验设计 TID的可行性和有效性.数值模拟结果表明,在不增加主结构绝对加速度响应的情况下, TID能够显著减小基础隔震结构的位移响应和基底剪力.  相似文献   

8.
This study examines the roles of soil-structure interaction (SSI), higher modes, and damping in a base-isolated structure built on multiple layers of soil overlying a half space. Closed-form solutions for the entire system, including a superstructure, seismic isolator, and numerous soil layers overlying a half-space, were obtained. The formulations obtained in this study simply in terms of well-known frequencies and mechanical impedance ratios can explicitly interpret the dynamic behavior of a base-isolated structure interacting with multiple soil layers overlying a half-space. The key factors influencing the performance of the isolation system are the damping ratio of the isolator and the ratio of the natural frequency of the fixed-base structure to that of the isolated structure by assuming that the superstructure moves as a rigid body. This study reveals that higher damping in the base isolator is unfavorable to higher mode responses that usually dominate the responses of the superstructure and that the damping mechanism plays an important role in transmitting energy in addition to absorbing energy. It is also concluded that it is possible to design a soft soil layer as an isolation system for isolating vibration energy.  相似文献   

9.
The paper analyzes the influence of friction pendulum system (FPS) isolator properties on the seismic performance of base‐isolated building frames. The behavior of these systems is analyzed by employing a two‐degree‐of‐freedom model accounting for the superstructure flexibility, whereas the FPS isolator behavior is described by adopting a widespread model that considers the variation of the friction coefficient with the velocity. The uncertainty in the seismic input is taken into account by considering a set of natural records with different characteristics scaled to increasing intensity levels. The variation of the statistics of the response parameters relevant to the seismic performance is investigated through the nondimensionalization of the motion equation and an extensive parametric study carried out for different isolator and system properties. The proposed approach allows to explore a wide range of situations while limiting the required nonlinear response history analyses. Two case studies consisting of base‐isolated building frames described as shear‐type systems are finally investigated in order to demonstrate the capabilities of the proposed simplified model in unveiling the essential characteristics of the performance of buildings isolated with FPS bearings. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

10.
A seismic isolated structure is usually a long-period structural system, which may encounter a low-frequency resonance problem when subjected to a near-fault earthquake that usually has a long-period pulse-like waveform. This long-period wave component may result in an enlargement of the base displacement and a decrease of the isolation efficiency. To overcome this problem, a rolling-based seismic isolator, referred to as roll-n-cage (RNC) isolator, has been recently proposed. The RNC isolator has a built-in buffer (braking) mechanism that limits the peak isolator displacements under severe earthquakes and prevents adjacent structural pounding. This paper addresses the problem of passive and hybrid mitigation of the potential inner pounding of the self-braking RNC isolator under near-fault earthquakes. Numerical results show that the RNC isolator can intrinsically limit the isolator displacements under near-fault earthquakes with less severe inner pounding using additional hysteretic damping and active control forces.  相似文献   

11.
本文提出一种评估同一地区不同类型结构的抗震投入产出效益的新指标,即结构价值损失比率。利用"5·12"汶川地震后对甘肃陇南的学校、住宅、办公、医院和生命线工程等9类建筑物的调查统计结果,研究了震害等级、经济损失与结构抗震初始投入之间的关系,建立了结构价值损失比率与结构初始投入之间的关系和高烈度区危房率与地震地面运动峰值之间的关系。对比分析了土-木组合、砖-木组合、砖砌体结构、非隔震框架结构和基础隔震结构等不同类型结构的抗震性能,并与实际鉴定的震害等级相比较。利用结构价值损失比率,初步说明了采用隔震新技术结构的减灾效益。  相似文献   

12.
This paper reports on an investigation of the seismic response of base-isolated reinforced concrete buildings, which considers various isolation system parameters under bidirectional near-fault and far-fault motions. Three-dimensional models of 4-, 8-, and 12-story base-isolated buildings with nonlinear effects in the isolation system and the superstructure are investigated, and nonlinear response history analysis is carried out. The bounding values of isolation system properties that incorporate the aging effect of isolators are also taken into account, as is the current state of practice in the design and analysis of base-isolated buildings. The response indicators of the buildings are studied for near-fault and far-fault motions weight-scaled to represent the design earthquake (DE) level and the risk-targeted maximum considered earthquake (MCER) level. Results of the nonlinear response history analyses indicate no structural damage under DE-level motions for near-fault and far-fault motions and for MCER-level far-fault motions, whereas minor structural damage is observed under MCER-level near-fault motions. Results of the base-isolated buildings are compared with their fixed-base counterparts. Significant reduction of the superstructure response of the 12-story base-isolated building compared to the fixed-base condition indicates that base isolation can be effectively used in taller buildings to enhance performance. Additionally, the applicability of a rigid superstructure to predict the isolator displacement demand is also investigated. It is found that the isolator displacements can be estimated accurately using a rigid body model for the superstructure for the buildings considered.  相似文献   

13.
In the current code requirements for the design of base isolation systems for buildings located at near-fault sites, the design engineer is faced with very large design displacements for the isolators. To reduce these displacements, supplementary dampers are often prescribed. These dampers reduce displacements, but at the expense of significant increases in interstorey drifts and floor accelerations in the superstructure. An elementary analysis based on a simple model of an isolated structure is used to demonstrate this dilemma. The model is linear and is based on modal analysis, but includes the modal coupling terms caused by high levels of damping in the isolation system. The equations are solved by a method that avoids complex modal analysis. Estimates of the important response quantities are obtained by the response spectrum method. It is shown that as the damping in the isolation system increases, the contribution of the modal coupling terms due to isolator damping in response to the superstructure becomes the dominant term. The isolator displacement and structural base shear may be reduced, but the floor accelerations and interstorey drift are increased. The results show that the use of supplemental dampers in seismic isolation is a misplaced effort and alternative strategies to solve the problem are suggested. Copyright © 1999 John Wiley & Sons, Ltd.  相似文献   

14.
The use of base isolation in developed countries including the U.S. and Japan has already been recognized as a very effective method for upgrading the seismic resistance of structures. In this study, an advanced base‐isolation system called the multiple friction pendulum system (MFPS) is investigated to understand its performance on seismic mitigation through full‐scale component and shaking table tests. The component tests of the advanced Teflon composite coated on the sliding surface show that the friction coefficient of the lubricant material is a function of the sliding velocity in the range of 0.03–0.12. The experimental results also indicate that there were no signs of degradation of the sliding interface observed after 2000 cycles of sliding displacements. A full‐scale MFPS isolator under a vertically compressive load of 8830 KN (900 tf) and horizontally cyclic displacements was tested in order to assess the feasibility of the MFPS isolator for its practical use. After 248 cycles of horizontal displacement reversals, the behaviour of the base isolator was almost identical to its behaviour during the first few cycles. The experimental results of the shaking table tests of a full‐scale steel structure isolated with MFPS isolators show that the MFPS device can isolate seismic transmitted energy effectively under soft‐soil‐deposit site earthquakes with long predominant periods as well as strong ground motions with short predominant periods. These test results demonstrate that the MFPS isolator possesses excellent durability and outstanding earthquake‐proof capability. Furthermore, the numerical results show that the mathematical model proposed in this study can well predict the seismic responses of a structure isolated with MFPS isolators. Copyright © 2006 John Wiley & Sons, Ltd.  相似文献   

15.
高层隔震结构非线性地震响应分析及设计方法研究   总被引:3,自引:0,他引:3  
高层隔震结构的分析理论和设计方法是目前隔震技术向高层建筑推广的2个关键理论问题。本文以高烈度区宿迁市已经竣工的高层隔震建筑阳光大厦为工程实例,对高层隔震结构的非线性地震响应分析方法进行了研究,包括隔震支座竖向不同拉压刚度的模拟、各种类型的隔震支座水平力学特性的准确模拟,以及不同地震动输入方式和输入角度对隔震支座受拉情况的影响分析等;在此基础上,对隔震层的设计方法进行了分析,提出了隔震层设计的基本原则,进而给出了控制隔震层设计的基本指标,包括隔震支座的长期面压、极值面压、隔震层偏心率等;最后,对高层隔震结构的相关构造要求进行了必要的说明。  相似文献   

16.
据震害统计,房屋抗震能力是影响灾害的主要因素,抗震能力一般由房屋抗震设防水平、结构类型、建造年代和房屋层数等因素决定,通过对房屋抗震能力的综合评定,以便采取更有针对性的地震灾害对策。本文通过遥感影像实现房屋基本信息的快速提取,提高房屋结构类型获取的便捷性,具有较高的准确度和可靠度,并利用抽样调查得到张家口万全区房屋建造年代和层数分布特点,结合当地抗震设防水平,建立房屋抗震能力指数指标体系,阐述房屋抗震能力现状,为地震灾害损失评估、风险普查、风险区划等工作提供参考。  相似文献   

17.
The use of base isolation for enhancing seismic resistibility has been proven as an efficient method in experimental and theoretical studies. It is usual to insert a flexible device in the horizontal direction to permit the most of relative deformation of a structure at this level. Because the rigidity of the superstructure is much higher than that of the base isolator underneath the structure, the behavior of the superstructure can be idealized as a rigid body during earthquakes. In general, hundreds of degrees of freedom and a step‐by‐step time history analysis are the basic requirements for calculating the seismic response of a base‐isolated structure under earthquakes. In order to develop a simple tool which can be easily adopted for calculating the seismic responses of the spherical sliding type isolated structures, a piecewise exact solution for predicting the seismic responses of base‐isolated structures has been derived in this study. The comparison between the experimental results conducted at the National Center for Research on Earthquake Engineering (NCREE) in Taiwan and the analytical results obtained from the piecewise exact solution show that the formulation derived in this study can predict the seismic responses of the base‐isolated structure with a very high accuracy. Copyright © 2005 John Wiley & Sons, Ltd.  相似文献   

18.
采用HBTA2.5程序,对一变刚度钢管混凝土短柱隔震结构进行了弹塑性时程分析。分析结果表明,其隔震装置的水平变形和耗能能力可以大大减轻地震对结构的影响。提出钢管混凝土短柱隔震结构在工程应用将有很好的发展前景。  相似文献   

19.
为研究罕遇地震下复合隔震村镇建筑的地震响应特征及设计参数,采用ABAQUS有限元软件建立了复合隔震结构、滑移隔震结构、砂垫层隔震结构以及传统的砌体结构四种模型,通过对比4种模型在不同滑移层摩擦系数及不同地震烈度下的加速度、位移及底部剪力等动力响应差异,得出复合隔震体系的地震响应特征及主要设计参数。结果表明:复合隔震体系具有最优的隔震效果,且滑移层摩擦系数越小,地震烈度越大,隔震效果越好。根据预设40%隔震率的要求,确定出不同抗震设防烈度区的滑移层摩擦系数取值范围。  相似文献   

20.
结合某多塔高层隔震结构,采用弹性时程分析方法,分析了隔震结构在多遇地震和罕遇地震作用下的响应。主要包括自振周期、层间剪力、倾覆力矩和楼层位移等内容。结果表明,与非隔震情形相比,结构的自振周期明显增大,地震作用得到了较大的衰减。结构在地震作用下的隔震效果明显,楼层剪力及倾覆力矩均得到折减,在罕遇地震作用下隔震效果尤为显著。层间位移主要集中在隔震层,上部结构的层间位移几乎为零。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏