1.
Cone penetrometer tests and HydroPunch® sampling were used to define the extent of volatile organic compounds in ground water. The investigation indicated that the combination of these techniques is effective for obtaining ground water samples for preliminary plume definition. HydroPunch samples can be collected in unconsolidated sediments and the analytical results obtained from these samples are comparable to those obtained from adjacent monitoring wells. This sampling method is a rapid and cost-effective screening technique for characterizing the extent of contaminant plumes in soft sediment environments. Use of this screening technique allowed monitoring wells to be located at the plume boundary, thereby reducing the number of wells installed and the overall cost of the plume definition program.  相似文献   

2.
Ground water at the Norman Landfill Research Site is contaminated by a leachate plume emanating from a closed, unlined landfill formerly operated by the city of Norman, Oklahoma, Ground water contaminated by the leachate plume is known to be elevated in the concentration of many, organic and inorganic constituents. Specific conductance, alkalinity, chloride, dissolved organic carbon, boron, sodium, strontium, and deuterium in ground water are considered to be indicators of the leachate plume at this site.
Leaf samples of broad-leafed cottonwood, Populus deltoides , were collected from 57 sites around the closed landfill. Cottonwood, a phreatophyte or "well plant," functions as a & surrogate well and serves as a ground water quality sampler. The leaf samples were combusted to ash and analyzed by instrumental neutron activation for 35 elements and by prompt-gamma instrumental neutron activation, for boron. A monitoring well was located within a few meters of a sampled cottonwood tree at 15 of the 57 sites, and ground water samples were collected from these monitoring wells simultaneously with a leaf sample. The chemical analyses of the ground water and leaf samples from these 15 sites indicated that boron, bromine, sodium, and strontium concentrations in leaves were significantly correlated with leachate indicator constituents in ground water. A point-plot map of selected percentiles indicated high concentrations of boron, bromine, and sodium in leaf ash from sites downgradient of the most recent landfill and from older landfills nearby.
Data from leaf analysis greatly extended the known areal extent of the leachate plume previously determined from a network of monitoring wells and geophysical surveys. This phytosgeochemical study provided a cost-effective method for assessing the extent of a leachate plume from an old landfill. Such a method may be useful as a preliminary sampling tool to guide the design of hydrogeochemical and geophysical studies.  相似文献   

3.
State-of-the-art analytical techniques are capable of detecting contamination In the part per billion (ppb) range or lower. At these levels, a truly representative ground water sample Is essential to precisely evaluate ground water quality. The design specifications of a ground water monitoring system are critical in ensuring the collection of representative samples, particularly throughout the long-term monitoring period.
The potential interfaces from commonly used synthetic well casings require a thorough assessment of site, hydrogeology and the geochemical properties of ground water. Once designed, the monitoring system must be installed following guidelines that ensure adequate seals to prevent contaminant migration during the installation process or at some time in the future. Additionally, maintaining the system so the wells are in hydraulic connection with the monitored zone as well as periodically Inspecting the physical integrity of the system can prolong the usefulness of the wells for ground water quality. When ground water quality data become suspect due to potential interferences from existing monitoring wells, an appropriate abandonment technique must be employed to adequately remove or destroy the well while completely sealing the borehole.
The results of an inspection of a monitoring system comprised of six 4-inch diameter PVC monitoring wells at a hazardous well facility Indicated that the wells were improperly installed and in some cases provided a pathway for contamination. Subsequent down hole television inspections confirmed inaccuracies between construction logs and the existing system as well as identified defects in casing materials. An abandonment program was designed which destroyed the well casings in place while simultaneously providing a competent seal of the re-drilled borehole.  相似文献   

4.
Hydrogeologic and ground water quality data obtained from a gas-driven multilevel sampler system and a polyvinyl chloride (PVC) monitoring well nest with the same aquifer communication intervals are compared. All monitoring points are in close proximity to each other. The study was conducted at an eight-acre uncontrolled hazardous waste site. The site is located in an alluvial valley composed of approximately 40 feet of alluvium overlying shale bedrock. The ground water at the site is contaminated with various organic constituents. A ground water monitoring network consisting of 26 conventional monitoring wells, nine observation well points, and six multilevel gas-driven samplers was established to characterize the hydrogeologic regime and define the vertical and horizontal extent of contamination in the vicinity of the abandoned chemical plant. As part of this study, a multilevel monitoring system was installed adjacent to a well nest. The communication zones of the multilevel samplers were placed at the same elevation as the sand packs of the well nest. The multilevel sampler system and well nest are located in a contaminated area directly downgradient of the site. A comparison of the vertical head distribution and ground water quality was performed between the well nest and the multilevel sampling system. The gas-driven multilevel sampling system consists of three gas-driven samplers that monitor separate intervals in the unconsolidated materials. The well nest, composed of two PVC monitoring wells in separate boreholes, has the same communication interval as the other two gas-driven samplers. Hydraulic head information for each multilevel sampler was obtained using capillary tubing. This was compared with heads obtained from the well nest utilizing an electric water level indicator. Chemical analyses from the PVC and multilevel sampler wells were performed and compared with one another. The analyses included organic acids, base neutrals, pesticides, PCBs, metals, volatile organics, TOX, TOC, CN, pH and specific conductance.  相似文献   

5.
Hassan AE 《Ground water》2006,44(5):710-722
A long-term monitoring well network is developed using complementary and simple approaches in conjunction with a stochastic ground water flow and transport model. The development is illustrated for a case study of a U.S. nuclear testing site (Shoal) that is undergoing environmental restoration. The network design builds on three different, yet complementary, tools for locating the monitoring wells with a main objective of detection monitoring. The first tool is applied to select potential siting horizons where monitoring wells could be located. The second tool is used to place monitoring wells in locations with high success probability. The success here is defined as the detection of migrating stochastic plumes before a certain mass percentage reaches a compliance boundary. The third tool is used to analyze detection efficiency of multiple combinations of three wells. Seventy-six different three-well networks are selected from 20 candidate locations and are evaluated for detection efficiency. From the 76 networks analyzed, 28 attain detection efficiency close to or above 70%. The results of the different analyses provide multiple alternatives for the locations of the three wells, which will become part of the long-term monitoring network at Shoal. A number of combinations are equally good, and the final choice will depend on practical considerations and future agreements between model sponsor and regulators.  相似文献   

6.
The screened auger is a laser-slotted, hollow-stem auger through which a representative sample of ground water is pumped from an aquifer and tested for water-quality parameters by appropriate field-screening methods. Screened auger sampling can be applied to ground water quality remedial investigations, providing:(1) a mechanism for determining a monitoring well's optimal screen placement in a contaminant plume; and (2) data to define the three-dimensional configuration of the contaminant plume.
Screened auger sampling has provided an efficient method for investigating hexavalent chromium and volatile organic compound contamination in two sandy aquifers in Cadillac, Michigan. The aquifers approach 200 feet in thickness and more than 1 square mile in area. A series of screened auger borings and monitoring wells was installed, and ground water was collected at 10-foot intervals as the boreholes were advanced to define the horizontal and vertical distribution of the contaminant plumes. The ability of the screened auger to obtain representative ground water samples was supported by the statistical comparison of field screening results and subsequent laboratory analysis of ground water from installed monitoring wells.  相似文献   

7.
In the BAT ground water sampling system, a stainless steel probe with a porous filter element is pushed vertically to the desired sampling depth. An evacuated glass sampling tube is then lowered down the penetration rods where it makes contact with the filter via a hypodermic needle and draws a pore fluid sample.
An investigation of the system was carried out at a number of sites contaminated by leaking underground gasoline storage tanks. Ground water samples obtained using the BAT system and adjacent monitoring wells were analyzed for volatile organic compounds (VOCs).
Because the BAT system is an in situ penetration device with a small filter length, it is possible to determine variations in contaminant concentration with depth. BAT samples in general exhibited higher recovery of VOCs than did bailer samples from adjacent monitoring wells screened over large intervals.
Much higher levels of VOCs were recovered when the probe was used with its 316 stainless steel filter than when using the high-density polyethylene (HDPE) filter. Significant sorption apparently occurred on the latter filter.
Because the BAT sample tubes are sealed and remain a closed system, the in situ water pressure is maintained. No significant loss of VOCs was found in sampling tubes containing headspace. Samples from the upper tube in the cascaded setup with headspace recovered levels of VOCs as high, or in a few cases higher, than the lower, no-headspace tubes.  相似文献   

8.
The Hydropunch™ is a stainless steel and Teflon® sampling tool that is capable of collecting a representative ground water sample without requiring the installation of a ground water monitoring well. To collect a sample, the Hydropunch (Patent #4669554) is connected to a small-diameter drive pipe and either driven or pushed hydraulically to the desired sampling depth. As the tool is advanced, it remains in the closed position, which prevents soil or water from entering the Hydropunch. Once the desired sampling depth is obtained, the tool is opened to the aquifer by pulling up the drive pipe approximately 1.5 feet (0.46m). In the open position, ground water can flow freely into the sample chamber of the tool. When the sample chamber is full, the Hydropunch is pulled to the surface. As the tool is retracted, check valves close and trap the ground water in the sample chamber. At the surface the sample is transferred from the Hydropunch to an appropriate sample container. The tool is a fast, inexpensive alternative for collecting ground water samples from a discrete interval. It is excellent for vertical profiling or defining the areal extent of a contaminant plume.  相似文献   

9.
The objective of most ground water quality monitoring programs is to obtain samples that are "representative" or that retain the physical and chemical properties of the ground water in an aquifer. Many factors can influence whether or not a particular sample is representative, but perhaps the most critical factor is the method or type of sampling device used to retrieve the sample.
The sampling equipment available today ranges from simple to highly sophisticated, and includes bailers, syringe devices, suction-lift pumps, gas-drive devices, bladder (Middelburg-type) pumps, gear-drive and helical rotor electric submersible pumps and gas-driven piston pumps. New devices are continually being developed for use in small-diameter wells in order to meet the needs of professionals engaged in implementing elaborate ground water monitoring programs.
In selecting a sampling device for a monitoring program, the professional must consider a number of details. Among the considerations are: the outside diameter of the device, the overall impact of the device on ground water sample integrity (including the materials from which the sampling device and associated equipment are made and the method by which the device delivers the sample), the capability of the device to purge the well of stagnant water, the rate and the ability to control the rate at which the sample is delivered, the depth limitations of the device, the ease of operating, cleaning and maintaining the device, the portability of the device and required accessory equipment, the reliability and durability of the device, and the initial and operational cost of the device and accessory equipment. Based on these considerations, each of the devices available for sampling ground water from small-diameter wells has its own unique set of advantages and disadvantages that make it suitable for sampling under specific sets of conditions. No one sampling device is applicable to all sampling situations.  相似文献   

10.
Micropurge sampling of ground water wells has been suggested as a possible replacement to traditional purge and sample methods. To compare methods, duplicate ground water samples were collected at two field sites using iraditional and micropurge methods. Samples were analyzed for selected organic and inorganic constituents, and the results were compared statistically. Analysis of the data using the nonparametric sign test indicates that within a 95 percent confidence interval, there was no significant difference between the two methods for the site contaminants and the majority of analytes. These analytical results were supported by visual observations with the colloidal borescope, which demonstrated impacts on the flow system in the well when using traditional sampling methods. Under selected circumstances, the results suggest replacing traditional sampling with micropurging based on reliability, cost, and waste minimization.  相似文献   

11.
Scientists engaged in the appraisal of ground water contaminated by organic substances are faced with the problems of difficult sample collection and timely chemical analysis. High-performance liquid chromatography was evaluated for on-site determination of specific organic contaminants in ground water samples and was used at three study sites. Organic solutes were determined directly in water samples, with little or no preparation, and usually in less than an hour after collection. This information improved sampling efficiency and was useful in screening for subsequent laboratory analysis. On two occasions, on-site analysis revealed that samples were undergoing rapid change, with major solutes being upgraded and alteration products being formed. In addition to sample stability, this technique proved valuable for monitoring other sampling factors such as compositional changes with respect to pumping, filtration, and cross contamination.  相似文献   

12.
Public health authorities generally recommend annual water-quality monitoring of rural water wells and shock chlorination if coliforms are detected. It is implicitly assumed that shock chlorination is effective in ridding most wells of bacteriological pathogens for months to years. Neither annual monitoring nor shock chlorination was effective in addressing coliform contamination of selected water wells in a small town developed on an alluvial aquifer where septic system effluents are impacting well water quality. Considerable temporal variation in total and fecal coliforms was observed in water wells monitored for a six-month period. Individual wells intermittently met and exceeded the drinking water criteria, indicating annual sampling was insufficient. Shock chlorination of three contaminated wells and their associated distribution systems proved ineffective because colonies apparently originated from outside the wells and reappeared over relatively short time periods (ranging from less than one week up to 21 weeks). The relatively fast and similar rate of recovery of total heterotrophic bacteria suggested they are related to biofilm formation in the wells and not to ground water contamination.  相似文献   

13.
Site characterization in densely fractured dolomite: comparison of methods   总被引:2,自引:0,他引:2  
One of the challenges in characterizing fractured-rock aquifers is determining whether the equivalent porous medium approximation is valid at the problem scale. Detailed hydrogeologic characterization completed at a small study site in a densely fractured dolomite has yielded an extensive data set that was used to evaluate the utility of the continuum and discrete-fracture approaches to aquifer characterization. There are two near-vertical sets of fractures at the site; near-horizontal bedding-plane partings constitute a third fracture set. Eighteen boreholes, including five coreholes, were drilled to a depth of approximately 10.6 m. Borehole geophysical logs revealed several laterally extensive horizontal fractures and dissolution zones. Flowmeter and short-interval packer testing identified which of these features were hydraulically important. A monitoring system, consisting of short-interval piezometers and multilevel samplers, was designed to monitor four horizontal fractures and two dissolution zones. The resulting network consisted of >70 sampling points and allowed detailed monitoring of head distributions in three dimensions. Comparison of distributions of hydraulic head and hydraulic conductivity determined by these two approaches suggests that even in a densely fractured-carbonate aquifer, a characterization approach using traditional long-interval monitoring wells is inadequate to characterize ground water movement for the purposes of regulatory monitoring or site remediation. In addition, traditional multiwell pumping tests yield an average or bulk hydraulic conductivity that is not adequate for predicting rapid ground water travel times through the fracture network, and the pumping test response does not appear to be an adequate tool for assessing whether the porous medium approximation is valid.  相似文献   

14.
The reliability of ground water monitoring information can be assured by careful selection of sample handling and analytical procedures. Sampling mechanism selection has been studied far less than analytical methodologies (Scalf et al. 1981, Nacht 1983). This study has as its primary goal the identification of reliable sampling mechanisms for purgeable organic compounds and gas-sensitive chemical parameters in ground water. Carefully controlled sampling experiments were run to investigate the error contributed to chemical results due to sampling mechanism alone. Fourteen commercial sampling devices in five mechanistic categories were evaluated for their performance in sample collection for solution parameters, dissolved gases and purgeable organic compounds. Systematic errors related to sampling mechanism can reduce the accuracy of monitoring data by factors of two to three times that involved in analytical procedures.  相似文献   

15.
The authors have recently used several innovative sampling techniques for ground water monitoring at hazardous waste sites. Two of these techniques were used for the first time on the Biscayne Aquifer Super-fund Project in Miami, Florida. This is the largest sampling program conducted so far under the U.S. Environmental Protection Agency (EPA) Superfund Program.
One sampling technique involved the use of the new ISCO Model 2600 submersible portable well sampling pump. A compressed air source forces water from the well into the pump casing and then delivers it to the surface (through a pulsating action). This pump was used in wells that could not be sampled with surface lift devices.
Another sampling technique involved the use of a Teflon manifold sampling device. The manifold is inserted into the top of the sampling bottle and a peristaltic pump creates a vacuum to draw the water sample from the well into the bottle. The major advantage of using this sampling technique for ground water monitoring at hazardous waste sites is the direct delivery of the water sample into the collection container. In this manner, the potential for contamination is reduced because, prior to delivery to the sample container, the sample contacts only the Teflon, which is well-known for its inert properties.
Quality assurance results from the Superfund project indicate that these sampling techniques are successful in reducing cross-contamination between monitoring wells. Analysis of field blanks using organic-free water in contact with these sampling devices did not show any concentration at or above the method detection limit for each priority pollutant.  相似文献   

16.
Waste disposal sites with volatile organic compounds (VOCs) frequently contain contaminants that are present in both the ground water and vadose zone. Vertical sampling is useful where transport of VOCs in the vadose zone may effect ground water and where steep vertical gradients in chemical concentrations are anticipated. Designs for combination ground water and gas sampling wells place the tubing inside the casing with the sample port penetrating the casing for sampling. This physically interferes with pump or sampler placement. This paper describes a well design that combines a ground water well with gas sampling ports by attaching the gas sampling tubing and ports to the exterior of the casing. Placement of the tubing on the exterior of the casing allows exact definition of gas port depth, reduces physical interference between the various monitoring equipment, and allows simultaneous remediation and monitoring in a single well. The usefulness and versatility of this design was demonstrated at the Idaho National Engineering and Environmental Laboratory (INEEL) with the installation of seven wells with 53 gas ports, in a geologic formation consisting of deep basalt with sedimentary interbeds at depths from 7.2 to 178 m below land surface. The INEEL combination well design is easy to construct, install, and operate.  相似文献   

17.
Principal component analysis is a data reduction technique used to identify the important components or factors that explain most of the variance of a system. This technique was extended to evaluating a ground water monitoring network where the variables are monitoring wells. The objective was to identify monitoring wells that are important in predicting the dynamic variation in potentiometric head at a location. The technique is demonstrated through an application to the monitoring network of the Bangkok area. Principal component analysis was carried out for all the monitoring wells of the aquifer, and a ranking scheme based on the frequency of occurrence of a particular well as principal well was developed. The decision maker with budget constraints can now opt to monitor principal wells which can adequately capture the potentiometric head variation in the aquifer. This was evaluated by comparing the observed potentiometric head distribution using data from all available wells and wells selected using the ranking scheme as a guideline.  相似文献   

18.
An analytical method is provided where the ground water practitioner can quickly determine the size (number of wells) and spacing of a well network capable of meeting a known ground water demand. In order to apply the method, two new parameters are derived that relate theoretical drawdown to the maximum drawdown that is achievable without mining the aquifer. The size of a well network is shown to be proportional to the ground water demand and inversely proportional to the transmissivity and available head. The spacing between wells in a supply well network is shown to be most sensitive to a derived parameter r HA/ 3, which is related to the available head and the propagation of drawdown away from a theoretical well if the total ground water demand was applied to that well. The method can be used to quickly determine the required spacing between wells in well networks of various sizes that are completed in confined aquifers with no leakance.  相似文献   

19.
Ground water monitoring networks can provide vital information for sustainable water resources management. This involves the measurement of ground water level, solute concentration, or both. This article deals with the former. It optimizes network distribution of piezometer or data sampling wells to effectively monitor ground water levels under an irrigation region while retaining adequate overall measurement accuracy. This article presents a structured process for applying principal component analysis (PCA) in optimizing a ground water monitoring network in an irrigation area of Australia. The PCA functions, distributed with the MATLAB package, were used to determine relative contributions of individual piezometers in capturing the spatiotemporal variation of ground water levels. Kriging gridding interpolation algorithm was used to render the data surface presentations and determine spatial differences in piezometeric surfaces using different number of data sets. The results show that the overall difference of ground water level between the original piezometer network and the optimized networks after the PCA process was applied is less than 20%, while the total number of piezometers in the optimized network is reduced by 63%, which will save the time and cost to monitor ground water levels in the irrigation area.  相似文献   

20.
Determination of the nature, extent, and rate of off-site chemical migration are common objectives of hazardous waste site investigations. Chemical analyses of water samples from monitoring wells and measurements of hydraulic head and hydraulic conductivity provide the basis for making these determinations. Accurate site assessment, therefore, depends upon the appropriate monitoring well design and sampling and testing procedures.
During the course of remedial investigations in Niagara Falls, New York, it has been necessary to evaluate the ground water quality and hydraulic characteristics of 5- to 30-feet thick overburden formations. Many of the monitoring wells completed to these formations consist of a partially penetrating screen (5 feet at the base of the formation) with a fully penetrating sandpack. Questions regarding how this well design influences the source of sampled ground water and hydraulic tests were examined using an extremely fine axisymmetric grid with SATURN, a two-dimensional, finite-element ground water model, and a particle tracking post-processor.
A discrete sensitivity analysis was made to determine how flow patterns induced by pumping at 1 gpm are affected by: different screen and sandpack configurations, the ratio of sandpack to formation hydraulic conductivities, heterogeneity, anisotropy, and sandpack thickness. The simulations show that the source (and chemistry given a non-uniform chemical distribution) of ground water sampled will vary considerably depending on a number of factors. Analysis of simulated drawdowns in the monitoring well during purging shows that calculated transmissivities for the range of well designs and conditions modeled will be accurate to within one-half order of magnitude.  相似文献   