首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 33 毫秒
1.
Three analytical studies of base‐isolated structures are carried out. First, six pairs of near‐fault motions oriented in directions parallel and normal to the fault were considered, and the average of the response spectra of these earthquake records was obtained. This study shows that in addition to pulse‐type displacements, these motions contain significant energy at high frequencies and that the real and pseudo‐velocity spectra are quite different. The second analysis modelled the response of a model of an isolated structure with a flexible superstructure to study the effect of isolation damping on the performance of different isolation systems under near‐fault motion. The results show that there exists a value of isolation system damping for which the superstructure acceleration for a given structural system attains a minimum value under near‐fault motion. Therefore, although increasing the bearing damping beyond a certain value may decrease the bearing displacement, it may transmit higher accelerations into the superstructure. Finally, the behaviour of four isolation systems subjected to the normal component of each of the near‐fault motions were studied, showing that EDF type isolation systems may be the optimum choice for the design of isolated structures in near‐fault locations. Copyright © 2001 John Wiley & Sons, Ltd.  相似文献   

2.
Rayleigh damping is commonly used to provide a source of energy dissipation in analyses of structures responding to dynamic loads such as earthquake ground motions. In a finite element model, the Rayleigh damping matrix consists of a mass‐proportional part and a stiffness‐proportional part; the latter typically uses the initial linear stiffness matrix of the structure. Under certain conditions, for example, a non‐linear analysis with softening non‐linearity, the damping forces generated by such a matrix can become unrealistically large compared to the restoring forces, resulting in an analysis being unconservative. Potential problems are demonstrated in this paper through a series of examples. A remedy to these problems is proposed in which bounds are imposed on the damping forces. Copyright © 2005 John Wiley & Sons, Ltd.  相似文献   

3.
The concentrically braced frame (CBF) structure is one of the most efficient steel structural systems to resist earthquakes. This system can dissipate energy during earthquakes through braces, which are expected to yield in tension and buckle in compression, while all other elements such as columns, beams and connections are expected to behave elastically. In this paper, the performance of single‐storey CBFs is assessed with nonlinear time‐history analysis, where a robust numerical model that simulates the behaviour of shake table tests is developed. The numerical model of the brace element used in the analysis was calibrated using data measured in physical tests on brace members subjected to cyclic loading. The model is then validated by comparing predictions from nonlinear time‐history analysis to measured performance of brace members in full scale shake table tests. Furthermore, the sensitivity of the performance of the CBF to different earthquake ground motions is investigated by subjecting the CBF to eight ground motions that have been scaled to have similar displacement response spectra. The comparative assessments presented in this work indicate that these developed numerical models can accurately capture the salient features related to the seismic behaviour of CBFs. A good agreement is found between the performance of the numerical and physical models in terms of maximum displacement, base shear force, energy dissipated and the equivalent viscous damping. The energy dissipated and, more particular, the equivalent viscous damping, are important parameters required when developing an accurate displacement‐based design methodology for CBFs subjected to earthquake loading. In this study, a relatively good prediction of the equivalent viscous damping is obtained from the numerical model when compared with data measured during the shake table tests. However, it was found that already established equations to determine the equivalent viscous damping of CBFs may give closer values to those obtained from the physical tests. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

4.
This paper presents findings from a comprehensive analytical and experimental study on the uplift‐restraining XY‐FP sliding isolation system. To investigate the effectiveness of the XY‐FP isolator and provide a rational basis for evaluating the efficacy of the developed mathematical model, an extensive experimental program was conducted on the earthquake simulator at the University at Buffalo. The experimental program involved a slender, five‐storey, scale‐model frame seismically isolated with four XY‐FP isolators subjected to simulations of historical horizontal and vertical ground motions. The experimental response demonstrates the validity of the concept and provides evidence for the effectiveness of the XY‐FP isolator in preventing uplift. A comprehensive analytical model capable of emulating the mechanical behaviour of the XY‐FP isolator is developed and implemented in program 3D‐BASIS‐ME. The newly enhanced program is used to predict the dynamic response of the seismically‐isolated model structure. Comparison of analytical predictions with experimental results attests to the efficacy of the analytical model for simulating the response of the XY‐FP isolator. With its appealing conceptual simplicity and its proven effectiveness, the new uplift‐restraining isolator has the potential to facilitate the application of seismic isolation even under the most extreme of conditions, including but not limited to near‐fault strong ground motions and uplift‐prone structural systems. Copyright © 2005 John Wiley & Sons, Ltd.  相似文献   

5.
Dynamic damaging potential of ground motions must be evaluated by the response behaviour of structures, and it is necessary to indicate what properties of ground motions are most appropriate for evaluation. For that purpose, the behaviour of energy input process and hysteretic energy dissipation are investigated in this study. It is found that the momentary input energy that is an index for the intensity of input energy is related to the characteristics of earthquakes such as cyclic or impulsive, and to the response displacement of structures immediately. On the basis of these results, a procedure is proposed to predict inelastic response displacement of structures by corresponding earthquake input energy to structural dissipated damping and hysteretic energy. In this procedure the earthquake response of structures is recognized as an input and dissipation process of energy, and therefore structural properties and damaging properties of ground motions can be taken into account more generally. Lastly, the studies of the pseudodynamic loading test of reinforced concrete structure specimens subjected to ground motions with different time duration are shown. The purpose of this test is to estimate the damaging properties of ground motions and the accuracy of the proposed prediction procedure. Copyright © 2002 John Wiley & Sons, Ltd.  相似文献   

6.
This paper presents the seismic behaviour of a concentrically braced frame system with self‐centring capability, in which a special type of bracing element termed reusable hysteretic damping brace (RHDB) is used. The RHDB is a passive energy dissipation device with its core energy‐dissipating component made of superelastic Nitinol wires. Compared with conventional bracing in steel structures, RHDB has a few prominent performance characteristics: damage free under frequent and design basis earthquakes in earthquake prone areas; minimal residual drifts due to the self‐centring capability of RHDB frame; and ability to survive several strong earthquakes without the need for repair or replacement. This paper also includes a brief discussion of the RHDB's mechanical configuration and analytical model for RHDB. The seismic performance study of RHDB frame was carried out through a non‐linear time history analysis of 3‐storey and 6‐storey RHDB frame buildings subjected to two suites of 20 earthquake ground motions. The analysis results were compared with buckling‐restrained brace (BRB) frames. This study shows that RHDB frame has a potential to outperform BRB frames by eliminating the residual drift problem. Copyright © 2007 John Wiley & Sons, Ltd.  相似文献   

7.
This experimental investigation deals with the earthquake behaviour of a nominally symmetric and a mass‐asymmetric three‐storey structural model isolated with the frictional pendulum system (FPS). Both accidental and natural torsion are evaluated in the structure by using recorded accelerations in all building floors and measured deformations at the isolation level. A 3D‐shaking table was used to subject the model to five different ground motions, including impulsive as well as far‐field subduction‐zone type earthquakes. Results show that the analytical predictions of the earthquake behaviour of the isolated structure, as obtained from a physical model of the FPS, are in close agreement with the true complex inelastic measured behaviour of the FPS. Besides, experimental results also validate previous observations about the importance of accounting for the variability of the normal loads in modelling the earthquake behaviour of FPS isolators. Measured torsional deformation amplifications at the base of the building vary, in the mean, from 2.5% to 6% for the symmetric and asymmetric structural configurations, respectively. In relation to the fixed base structure, the reduction factors for the base shear of the isolated structure are, in the mean, about 3.9 for both configurations. Finally, it is concluded that the FPS is capable of controlling the lateral–torsional motions of mass‐asymmetric structures quite effectively by aligning the centre of mass of the superstructure with the centre of pendular and frictional resistance of the isolation system. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

8.
In this research, an analytical model is developed to estimate the hydrodynamic damping ratio of liquid sloshing for wall bounded baffles using the velocity potential formulation and linear wave theory. Here, an analytical solution approach and experimental investigations are conducted for describing the hydrodynamic damping which is provided by vertical and horizontal baffles in partially filled rectangular liquid tanks. In order to evaluate the accuracy of the analytical solution which is developed in present work, a series of experiments are carried out with a rectangular liquid tank excited by harmonic oscillation. The parametric study is conducted on the damping efficiencies of both vertical and horizontal baffles with various dimensions and locations. According to the results of the present investigations, the hydrodynamic damping is significantly affected by the size and location of baffles. Furthermore, the validity of the developed analytical approach as well as the effectiveness of various baffle configurations are discussed. Finally, a simple approach is proposed for estimating the damping ratios of the baffles during earthquake motions.  相似文献   

9.
Precast concrete walls with unbonded post‐tensioning provide a simple self‐centering system. Yet, its application in seismic regions is not permitted as it is assumed to have no energy dissipation through a hysteretic mechanism. These walls, however, dissipate energy imparted to them because of the wall impacting the foundation during rocking and limited hysteretic action resulting from concrete nonlinearity. The energy dissipated due to rocking was ignored in previous experimental studies because they were conducted primarily using quasi‐static loading. Relying only on limited energy dissipation, a shake table study was conducted on four single rocking walls (SRWs) using multiple‐level earthquake input motions. All walls generally performed satisfactorily up to the design‐level earthquakes when their performance was assessed in terms of the maximum transient drift, maximum absolute acceleration, and residual drift. However, for the maximum considered earthquakes, the walls experienced peak lateral drifts greater than the permissible limits. Combining the experimental results with an analytical investigation, it is shown that SRWs can be designed as earthquake force‐resisting elements to produce satisfactory performance under design‐level and higher‐intensity earthquake motions. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

10.
11.
A procedure for the dynamic identification of the physical parameters of coupled base isolation systems is developed in the time domain. The isolation systems considered include high damping rubber bearings (HDRB) and low friction sliding bearings (LFSB). A bi‐linear hysteretic model is used alone or in parallel with a viscous damper to describe the behavior of the HDRB system, while a constant Coulomb friction device is used to model the LFSB system. After deriving the analytical dynamical solution for the coupled system under an imposed initial displacement, this is used in combination with the least‐squares method and an iterative procedure to identify the physical parameters of a given base isolation system belonging to the class described by the models considered. Performance and limitations of the proposed procedure are highlighted by numerical applications. The procedure is then applied to a real base isolation system using data from static and dynamic tests performed on a building at Solarino. The results of the proposed identification procedure have been compared to available laboratory data and the agreement is within ±10%. However, the need for improvement both in models and testing procedures also emerges from the numerical applications and results obtained. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

12.
Properly fabricated triangular‐plate added damping and stiffness (TADAS) devices can sustain a large number of yield reversals without strength degradation, thereby dissipating a significant amount of earthquake‐induced energy. A pronounced isotropic‐hardening effect is recognized in the force‐deformation relationships of the TADAS devices made from two grades of low yield strength steel. The proposed plasticity‐fibre model employing two surfaces (a yield surface and a bounding surface) in plasticity theory accurately predicts the experimental responses of the TADAS devices. This model is also implemented into a computer program DRAIN2D+ to investigate a frame response with the TADAS devices. Substructure pseudo‐dynamic tests and analytical studies of a two‐storey steel frame constructed with the low yield strength steel, LYP‐100 or LYP‐235 grade, TADAS devices confirm that the dynamic structural response can only be predicted if the proposed plasticity‐fibre model is used for LYP‐100 steel TADAS device. Copyright © 2002 John Wiley & Sons, Ltd.  相似文献   

13.
The rail‐counterweight systems in building elevators are known to be susceptible to earthquake‐induced ground motions. Besides avoiding costly repairs and economic disruptions, it is of special interest to maintain the functionality of the elevators in critical facilities such as hospitals during, and especially after, a strong earthquake event. This paper presents an approach to develop a realistic analytical model of these vulnerable systems to study their seismic response behaviour. The model includes the flexibilities of the guidance and supporting components of the counterweights in a systematic manner. Currently only the linear response behaviour is considered; however, the sources of non‐linearities in the flexible components are clearly identified. The model considers the effect of the differential support motions from the building. Both the out‐of‐plane and in‐plane responses of the rail‐counterweight are studied and included in the stress calculations. Several sets of numerical results considering simultaneous action of the two orthogonal components of historic earthquakes are obtained to study the seismic response characteristics of the rail‐counterweight system. Copyright © 2001 John Wiley & Sons, Ltd.  相似文献   

14.
This paper presents a new analytical model for describing the large rocking response of an elastic multi‐mass structure resting on ideally rigid ground. Using the experimental results from a rocking steel column, the ability of the proposed analytical model to estimate the rocking and translational acceleration response under free vibration, pulse and earthquake excitations is evaluated. It is observed that the classical treatment of impact may result in an unrealistically large transfer of energy to vibrations. Therefore a new Dirac‐delta type impact model that spreads the effects of impact over time and space is proposed. The use of a Dirac‐delta model and accurate restitution factors play a pivotal role in prediction of rocking and acceleration responses. In order to characterize the nonlinear response better, a modal analysis of the linearized system is proposed. With this approach, the vibration mode frequencies and shapes during rocking action were determined. A comparison of analytical and experimental modal estimations suggests good agreement. The results emphasize that the vibration characteristics of several vibration modes are affected by rocking action, and these modes may be excited at impact. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

15.
This paper considers the dynamical behaviour of a structural model with foundation uplift. The equations of motion of the system considered are derived for large displacements thus allowing for the eventual overturning of the system. The transition conditions between successive phases of motion, derived in terms of the specific Lagrangian co‐ordinates used in the formulation of the equations of motion, present innovative aspects which resolve some previously inexplicable behaviour in the structural response reported in the literature. The dynamical behaviour of the model is considered under impulsive and long‐duration ground motions. The minimum horizontal acceleration impulses for the uplift and the overturning of the system are evaluated in analytical form. The sensitivity of the model to uplifting and to overturning under impulsive excitations is established as a function of few significant structural parameters. Numerical applications have been performed changing either the structural parameters or the loading parameter, in order to analyse several dynamical behaviours and also to validate the analytical results. For earthquake ground motions the results, reported in the form of response spectra, show that linearized models generally underestimate, sometimes significantly, the structural response. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

16.
A method for parametric system identification of classically damped linear system in frequency domain is adopted and extended for non‐classically damped linear systems subjected up to six components of earthquake ground motions. This method is able to work in multi‐input/multi‐output (MIMO) case. The response of a two‐degree‐of‐freedom model with non‐classical damping, excited by one‐component earthquake ground motion, is simulated and used to verify the proposed system identification method in the single‐input/multi‐output case. Also, the records of a 10 storey real building during the Northridge earthquake is used to verify the proposed system identification method in the MIMO case. In this case, at first, a single‐input/multi‐output assumption is considered for the system and modal parameters are identified, then other components of earthquake ground motions are added, respectively, and the modal parameters are identified again. This procedure is repeated until all four components of earthquake ground motions which are measured at the base level of the building are included in the identification process. The results of identification of real building show that consideration of non‐classical damping and inclusion of the multi‐components effect of earthquake ground motions can improve the least‐squares match between the finite Fourier transforms of recorded and calculated acceleration responses. Copyright © 2006 John Wiley & Sons, Ltd.  相似文献   

17.
Buckling is usually conceived as an unstable structural behavior leading to lateral instability of axially loaded members, if not properly supported. However, a pre‐bent strip would become an excellent seismic energy‐dissipative device if it is deformed in a guided direction and range. Geometrically large lateral deformation of the steel strips in buckling leads to inelastic behavior of the material and dissipates energy as a consequence. The purpose of this study is to propose a new type of seismic damper in the form of braces based on pre‐bent steel strips. The nonlinear elastic stiffness of monotonously loaded pre‐bent strips in both compression and tension is derived. The energy‐dissipative characteristics of the proposed damping device are investigated via component tests under cyclic loads. Experimental results indicate that the force–displacement relationship of pre‐bent strips in cyclic loads exhibits mechanical characteristics of displacement‐dependent dampers. A series of seismic performance tests has been conducted further to verify the feasibility and effectiveness of using the proposed device as seismic dampers. Encouraging test results have been obtained, suggesting feasibility of the proposed device for earthquake‐resistant design. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

18.
Damping formulation for nonlinear 1D site response analyses   总被引:2,自引:0,他引:2  
Measurements and observations of ground shaking during large earthquakes have demonstrated the predominant role of site effects in the response of infrastructure during a seismic event. Despite significant efforts to model the hysteretic response and nonlinearity of soils due to medium and large ground motions, the most widely accepted nonlinear site response methods are not able to represent simultaneously the changes of stiffness and energy dissipation (damping) observed in both laboratory tests and during earthquake events. This paper presents two new soil damping formulations implemented in nonlinear one-dimensional site response analysis for small and large strains. The first formulation introduces an approach to construct a frequency-independent viscous damping matrix which reduces the over-damping at high frequencies, and therefore, the filtering at those frequencies. The second formulation introduces a reduction factor that modifies the extended Masing loading/unloading strain–stress relationship to match measured modulus reduction and damping curves simultaneously over a wide range of shear strains. A set of examples are introduced to illustrate the effect of using the two proposed formulations, separately and simultaneously, in nonlinear site response analyses.  相似文献   

19.
This paper proposes a simple conceptual mathematical model for the mechanical components of the NEES‐UCSD large high‐performance outdoor shaking table and focuses on the identification of the parameters of the model by using an extensive set of experimental data. An identification approach based on the measured hysteresis response is used to determine the fundamental model parameters including the effective horizontal mass, effective horizontal stiffness of the table, and the coefficients of the classical Coulomb friction and viscous damping elements representing the various dissipative forces in the system. The effectiveness of the proposed conceptual model is verified through a comparison of analytical predictions with experimental results for various tests conducted on the system. The resulting mathematical model will be used in future studies to model the mechanical components of the shake table in a comprehensive physics‐based model of the entire mechanical, hydraulic, and electronic system. Copyright © 2007 John Wiley & Sons, Ltd.  相似文献   

20.
The seismic response of free‐standing classical columns is analysed numerically through implementation of the distinct element method. Typical sections of two ancient temples are modelled and studied parametrically, in order to identify the main factors affecting the stability and to improve our understanding of the earthquake behaviour of such structures. The models were first subjected to harmonic base motions. The analysis showed that, for frequencies usually encountered in earthquake motions, intact multi‐drum free‐standing columns can withstand large amplitude harmonic excitations without collapse. The dynamic resistance decreases rapidly as the period of the harmonic excitation increases. Imperfections, such as initial tilt of the column or loss of contact area due to edge damage, also reduce the stability of the system significantly. The effects of such imperfections could be additive and the cumulative effect of many imperfections may render deteriorating abandoned monuments vulnerable to earthquakes. The response of more complete sections of the temple, such as two columns coupled with an architrave, did not deviate systematically from that of the single multi‐drum column or indeed of the equivalent single block. Therefore, a much simpler single block analysis can be used to size‐up the seismic threat to the monument. The model of the column of the Temple of Apollo at Bassae was also tested under recorded earthquake motions by scaling‐up the acceleration amplitude progressively until collapse of the column. It was found that the columns are particularly vulnerable to long‐period impulsive earthquake motions. A comparison of the instability thresholds associated with harmonic excitations and earthquake motions throws more light onto the dynamic response: it appears that around three cycles of monochromatic excitation at the predominant period of the expected earthquake motions lead to a gross prediction of the stability of a classical column during an earthquake. Copyright © 2000 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号