首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 265 毫秒
1.
This experimental investigation deals with the earthquake behaviour of a nominally symmetric and a mass‐asymmetric three‐storey structural model isolated with the frictional pendulum system (FPS). Both accidental and natural torsion are evaluated in the structure by using recorded accelerations in all building floors and measured deformations at the isolation level. A 3D‐shaking table was used to subject the model to five different ground motions, including impulsive as well as far‐field subduction‐zone type earthquakes. Results show that the analytical predictions of the earthquake behaviour of the isolated structure, as obtained from a physical model of the FPS, are in close agreement with the true complex inelastic measured behaviour of the FPS. Besides, experimental results also validate previous observations about the importance of accounting for the variability of the normal loads in modelling the earthquake behaviour of FPS isolators. Measured torsional deformation amplifications at the base of the building vary, in the mean, from 2.5% to 6% for the symmetric and asymmetric structural configurations, respectively. In relation to the fixed base structure, the reduction factors for the base shear of the isolated structure are, in the mean, about 3.9 for both configurations. Finally, it is concluded that the FPS is capable of controlling the lateral–torsional motions of mass‐asymmetric structures quite effectively by aligning the centre of mass of the superstructure with the centre of pendular and frictional resistance of the isolation system. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

2.
3.
Discrepancies between the computed and actual values of the structural element stiffness imply that a building with nominally symmetric plan is actually asymmetric to some unknown degree and will undergo torsional vibration when subjected to purely translational ground motion. Such accidental torsion leads to increase in structural element deformations which is shown to be essentially insensitive to the uncoupled lateral vibration period of the system but is affected strongly by the ratio of uncoupled lateral and torsional vibration periods. The structural deformations increase, in the mean, by at most 10 and 5 per cent for R/C and steel buildings, respectively, and by much smaller amounts for a wide range of system parameters. The increase in structural deformations due to stiffness uncertainty is shown to be much smaller than implied by the accidental torsional provisions in the Uniform Building Code and most other building codes.  相似文献   

4.
The paper deals with the applicability of the extended N2 method to base‐isolated plan‐asymmetric building structures. The results obtained by the usual pushover analysis of a 3D structural model are further combined with the aid of linear dynamic (spectral) analysis to account for the dynamic effects caused by structural asymmetry. In the paper, the method has been applied to the seismic analysis of a mass‐eccentric four‐storeyed RC frame building isolated with lead rubber bearings. Three different positions of the center of isolation system (CI) with respect to the center of mass (CM) and the center of stiffness of the superstructure (CS) were considered. The response was analyzed for three different eccentricities, three different torsional to lateral frequency ratios of the superstructure, and two ground motion intensities. The stiffness of the isolators was selected for three different protection levels, which resulted in elastic as well as moderately to excessively damaged superstructure performance levels. The results are presented in terms of the top, base and relative displacements, as well as the stiff/flexible side amplification factors. A more detailed insight into the nonlinear behavior of the superstructure is given in a form of ductility factors for the flexible and stiff side frames. The results of the extended N2 method for selected lateral load distributions are compared with the average results of nonlinear dynamic analyses. It was concluded that the extended N2 method could, with certain limitations, provide a reasonable prediction of the torsional influences in minor to moderately asymmetric base‐isolated structures. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

5.
In the current code requirements for the design of base isolation systems for buildings located at near-fault sites, the design engineer is faced with very large design displacements for the isolators. To reduce these displacements, supplementary dampers are often prescribed. These dampers reduce displacements, but at the expense of significant increases in interstorey drifts and floor accelerations in the superstructure. An elementary analysis based on a simple model of an isolated structure is used to demonstrate this dilemma. The model is linear and is based on modal analysis, but includes the modal coupling terms caused by high levels of damping in the isolation system. The equations are solved by a method that avoids complex modal analysis. Estimates of the important response quantities are obtained by the response spectrum method. It is shown that as the damping in the isolation system increases, the contribution of the modal coupling terms due to isolator damping in response to the superstructure becomes the dominant term. The isolator displacement and structural base shear may be reduced, but the floor accelerations and interstorey drift are increased. The results show that the use of supplemental dampers in seismic isolation is a misplaced effort and alternative strategies to solve the problem are suggested. Copyright © 1999 John Wiley & Sons, Ltd.  相似文献   

6.
摩擦摆基础隔震上部偏心结构地震反应影响因素分析   总被引:1,自引:0,他引:1  
对上部结构存在偏心的摩擦摆基础隔震结构进行了水平双向地震作用下的地震反应分析,研究了上部结构偏心距和抗扭刚度对结构地震反应的影响。分析表明:上部结构偏心距对上部结构和隔震层的位移反应和加速度反应均有较大影响,即使在上部结构偏心距较小时,其对结构地震反应仍有一定程度的影响;上部结构的抗扭刚度对上部结构的加速度反应影响较小,而对上部结构的位移反应影响较大;上部结构的抗扭刚度对隔震层的加速度反应和位移反应影响较小。因而,对于上部结构存在偏心的摩擦摆基础隔震结构,应减小上部结构偏心距并增大其抗扭刚度以减小摩擦摆基础隔震结构的扭转反应。  相似文献   

7.
A procedure based on rigorous non‐linear analysis is presented that estimates the peak deformation among all isolators in an asymmetric building due to strong ground motion. The governing equations are reduced to a form such that the median normalized deformation due to an ensemble of ground motions with given corner period Td depends primarily on four global parameters of the isolation system: the isolation period Tb, the normalized strength η, the torsional‐to‐lateral frequency ratio Ωθ, and the normalized stiffness eccentricity eb/r. The median ratio of the deformations of the asymmetric and corresponding symmetric systems is shown to depend only weakly on Tb, η, and Ωθ, but increases with eb/r. The equation developed to estimate the largest ratio among all isolators depends only on the stiffness eccentricity and the distance from the center of mass to the outlying isolator. This equation, multiplied by an earlier equation for the deformation of the corresponding symmetric system, provides a design equation to estimate the deformations of asymmetric systems. This design equation conservatively estimates the peak deformation among all isolators, but is generally within 10% of the ‘exact’ value. Relative to the non‐linear procedure presented, the peak isolator deformation is shown to be significantly underestimated by the U.S. building code procedures. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

8.
Numerical simulations and parametric studies have been used to investigate the influence of potential poundings of seismically isolated buildings with adjacent structures on the effectiveness of seismic isolation. Poundings are assumed to occur at the isolation level between the seismically isolated building and the surrounding moat wall. After assessing some common force‐based impact models, a variation of the linear viscoelastic impact model is proposed to avoid tensile impact forces during detachment, while enabling the consideration of permanent plastic deformations at the vicinity of the impact. A large number of numerical simulations of seismically isolated buildings with different characteristics have been conducted under six earthquake excitations in order to investigate the influence of various design parameters and conditions on the peak floor accelerations and interstorey deflections during poundings. The numerical simulations demonstrate that poundings may substantially increase floor accelerations, especially t the base floor where impacts occur. Higher modes of vibration are excided during poundings, increasing the interstorey deflections, instead of retaining an almost rigid‐body motion of the superstructure, which is aimed with seismic isolation. Impact stiffness seems to affect significantly the acceleration response at the isolation level, while the displacement response is more insensitive to the variation of the impact stiffness. Finally, the results indicate that providing excessive flexibility at the isolation system to minimize the floor accelerations may lead to a building vulnerable to poundings, if the available seismic gap is limited. Copyright © 2007 John Wiley & Sons, Ltd.  相似文献   

9.
Effectiveness of a new semiactive independently variable stiffness (SAIVS) device in reducing seismic response of sliding base isolated buildings is evaluated analytically and experimentally. Through analytical and experimental study of force—displacement behaviour of the SAIVS device, it is shown that the device can vary stiffness continuously and smoothly between minimum and maximum stiffness. Passive sliding base isolation systems reduce interstorey drifts and superstructure accelerations, but with increased base displacements, which is undesirable, under large velocity near fault pulse type earthquakes. It is a common practice to incorporate non‐linear passive dampers into the isolation system to reduce bearing displacements. Incorporation of passive dampers, however, may result in increased superstructure accelerations and drifts; while, properly designed passive dampers can be beneficial. A viable alternative is to use semiactive variable stiffness systems, which can vary the period of the sliding base isolated buildings in real time, to simultaneously reduce bearing displacements and superstructure responses further than the passive systems, which deserves investigation. This study investigates the performance of a 1:5 scaled smart sliding base isolated building model equipped with the SAIVS device analytically and experimentally, under near fault earthquakes, by developing a new moving average non‐linear tangential stiffness control algorithm for control of the SAIVS device. The SAIVS device reduces bearing displacements further than the passive cases, while maintaining isolation level forces and superstructure responses at the same level as the passive minimum stiffness case, indicating the significant potential of the SAIVS system. Copyright © 2005 John Wiley & Sons, Ltd.  相似文献   

10.
This article presents a physical model for frictional pendulum isolators (FPS) that is ready to be implemented in most commercial software. The model is capable of accounting for effects such as large deformations, sticking, and uplift and impact by sensing the normal loads in the isolators through a gap element. Sticking has been incorporated into the model by extending the Park–Wen hysteretic model to the case of large deformations. The proposed model has been tested against a theoretically ‘exact’ formulation leading to essentially identical results. To facilitate its use, the physical FPS model has been cast into a typical non‐linear structural element format, i.e. with deformation as input and restoring force as output. Examples of a building and a bridge have been chosen to show the potential of the element and to provide further insight into the earthquake response of structures with FPS isolators; in particular, in aspects such as the orientation in placement of the isolator, sticking, P? Δ, and other large deformation effects. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

11.
The isolation systems are usually made of rubber bearings that are sometimes coupled in hybrid combination with frictional devices; this is the case of an in-site experimental campaign, performed on a base isolated apartment building in Rapolla (south of Italy). Several dropout tests at initial displacements up to 17cm allowed to obtain in-site information on the true dynamic response of the isolation system (building and isolators). The tests carried out allow a comparison between the free vibration responses of a building, isolated by using a 28 HDRB isolation system only, or an HDRB-Friction Sliders Hybrid one. The paper highlights the main differences of the response in the superstructure (the structure over the isolation system) obtained by using only HDRB isolation system, or the Hybrid one (HDRB and Friction Sliders in parallel system). Analysis and comparisons of experimental data, show the influence of nonlinearities on structural higher modes amplification, especially observed by using the higher nonlinear Hybrid isolation system. Tests results confirm that, in the case of a regular superstructure, like the Rapolla building, the isolation system nonlinearities influence the structural response.  相似文献   

12.
In this study friction pendulum system (FPS) bearings and precast-prestressed pile (PPP) isolators are considered as base isolation devices for a Chilean confined masonry house. The house is numerically modeled using a multiple degree-of-freedom approach that is calibrated with experimental data. Dynamic behavior of the FPS and PPP isolators is simulated using analytical formulations based on laboratory testing. Optimization of the isolators is performed using an earthquake that is generated to match the design spectrum for the house based on Chilean seismic code. A non-dominated sorting genetic algorithm (NSGA-II) is applied to carry out the optimization. Seismic response of the base-isolated structure subjected to a suite of ground motions is compared to the performance of the traditionally-constructed structure by means of several performance indices (PIs). Numerical simulations indicate that the PPP isolation system is more effective in reducing the base and structural shear, interstory drift, and floor acceleration of the structure than the FPS isolation system, although both systems result in substantial reductions of the response.  相似文献   

13.
This investigation deals with the torsional balance of the earthquake response and design of elastic asymmetric structures with frictional dampers. Plan asymmetry leads to an uneven lateral deformation demand among structural members and to unbalanced designs with larger capacities in some resisting planes. Frictional dampers are capable of controlling lateral‐torsional coupling by placing the so‐called empirical center of balance (ECB) of the structure at equal distance from all edges of the building. This rule is developed for single‐story systems with linear and inelastic behavior. However, recently obtained theoretical and experimental results demonstrate that this rule carries over to multistory structures. Results show that the peak displacement demand at the building edges and that of resisting planes equidistant from the geometric center may be similar if the damper is optimally placed. It is also shown that torsional amplification of the edge displacements of arbitrary asymmetric structures relative to the displacement of the symmetric counterparts are approximately bound by a factor of 2. Furthermore, frictional dampers are equally effective in controlling lateral‐torsional coupling of torsionally flexible as well as stiff structures. Copyright © 2005 John Wiley & Sons, Ltd.  相似文献   

14.
周力强  王玉山  王迪 《地震工程学报》2020,42(3):624-628,664
随着基础隔震技术的发展,我国在高烈度地区广泛开展基础隔震技术的工程应用必将成为一种趋势,但由于建筑功能和建筑造型的丰富多彩,结构的质量中心和刚度中心也趋于分布不均匀,以三层的钢框架结构为分析模型,利用结构分析软件Sap2000对上部结构质量中心和隔震层质量中心、刚度中心分布不均匀的三种方案进行单向水平地震作用下的非线性时程分析,分析结果表明:上部结构质量中心与隔震层质量中心存在偏心距对结构的扭转效应以及地震响应有较大的影响,减小上部结构的偏心距对调整结构的水平地震响应的影响成效最为显著;对于隔震层而言,隔震层的刚度中心偏心距较质量中心偏心距对上部结构的影响更大,有效控制隔震层刚度中心的偏心距在隔震设计中会更加有效。  相似文献   

15.
Because a conventional isolation system with constant isolation frequency is usually a long‐period dynamic system, its seismic response is likely to be amplified in earthquakes with strong long‐period wave components, such as near‐fault ground motions. Seismic isolators with variable mechanical properties may provide a promising solution to alleviate this problem. To this end, in this work sliding isolators with variable curvature (SIVC) were studied experimentally. An SIVC isolator is similar to a friction pendulum system (FPS) isolator, except that its sliding surface has variable curvature rather being spherical. As a result, the SIVC's isolation stiffness that is proportional to the curvature becomes a function of the isolator displacement. By appropriately designing the geometry of the sliding surface, the SIVC is able to possess favorable hysteretic behavior. In order to prove the applicability of the SIVC concept, several prototype SIVC isolators, whose sliding surfaces are defined by a sixth‐order polynomial function, were fabricated and tested in this study. A cyclic element test on the prototype SIVC isolators and a shaking table test on an SIVC isolated steel frame were all conducted. The results of both tests have verified that the prototype SIVC isolators do indeed have the hysteretic property of variable stiffness as prescribed by the derived formulas in this study. Moreover, it is also demonstrated that the proposed SIVC is able to effectively reduce the isolator drift in a near‐fault earthquake with strong long‐period components, as compared with that of an FPS system with the same friction coefficient. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

16.
The aim of this work is to propose seismic reliability‐based relationships between the strength reduction factors and the displacement ductility demand of nonlinear structural systems equipped with friction pendulum isolators (FPS) depending on the structural properties. The isolated structures are described by employing an equivalent 2dof model characterized by a perfectly elastoplastic rule to account for the inelastic response of the superstructure, whereas, the FPS behavior is described by a velocity‐dependent model. An extensive parametric study is carried out encompassing a wide range of elastic and inelastic building properties, different seismic intensity levels and considering the friction coefficient as a random variable. Defined a set of natural seismic records and scaled to the seismic intensity corresponding to life safety limit state for L'Aquila site (Italy) according to NTC08, the inelastic characteristics of the superstructures are designed as the ratio between the average elastic responses and increasing strength reduction factors. Incremental dynamic analyses (IDAs) are developed to evaluate the seismic fragility curves of both the inelastic superstructure and the isolation level assuming different values of the corresponding limit states. Integrating the fragility curves with the seismic hazard curves related to L'Aquila site (Italy), the reliability curves of the equivalent inelastic base‐isolated structural systems, with a design life of 50 years, are derived proposing seismic reliability‐based regression expressions between the displacement ductility demand and the strength reduction factors for the superstructure as well as seismic reliability‐based design (SRBD) abacuses useful to define the FPS properties. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

17.
The Friction Pendulum System (FPS) isolator is commonly used as a base isolation system in buildings. In this paper, a new tunable FPS (TFPS) isolator is proposed and developed to act as a semi‐active control system by combining the traditional FPS and semi‐active control concept. Theoretical analysis and physical tests were carried out to investigate the behavior of the proposed TFPS isolator. The experimental and theoretical results were in good agreement, both suggesting that the friction force of the TFPS isolator can be tuned to achieve seismic isolation of the structure. A series of numerical simulations of a base‐isolated structure equipped with the proposed TFPS isolator and subjected to earthquake ground motions were also conducted. In the analyses, the linear quadratic regulator (LQR) method was adopted to control the friction force of the proposed TFPS, and the applicability and effectiveness of the TFPS in controlling the structure's seismic responses were investigated. The simulation results showed that the TFPS can reduce the displacement of the isolation layer without significantly increasing the floor acceleration and inter‐story displacement of the superstructure, confirming that the TFPS can effectively control a base‐isolated structure under earthquake ground motions.  相似文献   

18.
为了建立单轴平扭耦联基础隔震结构的动力简化分析方法,探讨了影响结构扭转反应的参数取值规律,首先基于层单元模型,通过假定上部结构楼层回转半径、偏心距、弹力半径相等,推导了单轴平扭耦联基础隔震结构线性化的动力计算方程;其次,运用该简化分析方程,通过一算例进行了动力响应的参数分析。结果表明:调整隔震层刚心使其与上部结构质心位置接近,可显著降低偏心隔震结构扭转反应;增大隔震层刚度半径及阻尼半径可有效减少或抑制结构扭转反应;所建简化分析方程能有效模拟偏心隔震结构动力响应。  相似文献   

19.
The response of multi‐storey structures can be controlled under earthquake actions by installing seismic isolators at various storey levels. By vertically distributing isolation devices at various elevations, the designer is provided with numerous options to appropriately adjust the seismic performance of a building. However, introducing seismic isolators at various storey levels is not a straightforward task, as it may lead to favourable or unfavourable structural behaviour depending on a large number of factors. As a consequence, a rather chaotic decision space of seismic isolation configurations arises, within which a favourable solution needs to be located. The search for favourable isolators' configurations is formulated in this work as a single‐objective optimization task. The aim of the optimization process is to minimize the maximum floor acceleration of the building under consideration, while constraints are specified to control the maximum interstorey drift, the maximum base displacement and the total seismic isolation cost. A genetic algorithm is implemented to perform this optimization task, which selectively introduces seismic isolators at various elevations, in order to identify the optimal configuration for the isolators satisfying the pre‐specified constraints. This way, optimized earthquake response of multi‐storey buildings can be obtained. The effectiveness of the proposed optimization procedure in the design of a seismically isolated structure is demonstrated in a numerical study using time‐history analyses of a typical six‐storey building. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

20.
In the paper a simplified nonlinear method has been applied to the analysis of base‐isolated structures. In the first part, a three‐linear idealization of the capacity curve is proposed. The initial stiffness is defined based on the first yielding point in the superstructure, whereas the secondary slope depends on the failure mechanism of the superstructure. A consequence is a much more pronounced secondary slope, which does not correspond to the presumptions used in the originally proposed N2 method. A parametric nonlinear dynamic study of single degree of freedom systems with different hardening slopes and damping has been performed for an ensemble of seven EC8 spectrum‐compatible artificial accelerograms. It was concluded that, in the long‐period range, the equal displacement rule could be assumed also for the proposed systems with non‐zero post‐yield stiffness. In the second part, the proposed idealization was used for the analysis of isolated RC frame buildings that were isolated with different (lead) rubber‐bearing isolation systems. The stiffness of the isolators was selected for three different protection levels and for three different ground motion intensities, which have resulted in elastic as well as moderately and fully damaged superstructure performance levels. Three different lateral load distributions were investigated. It was observed that a triangular distribution, with an additional force at the base, works best in the majority of practical cases. It was concluded that the N2 method can, in general, provide a reasonably accurate prediction of the actual top displacement, as well as of the expected damage to the superstructure. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   