首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 390 毫秒
1.
Overturning of a structure causes variations in the normal loads of the isolators supporting that structure. For frictional isolators, such variation leads to changes in the frictional forces developed and, hence, in the strength distribution in plan. For frictional pendulum system (FPS) isolators, it also causes changes in the pendular action, i.e. in the stiffness distribution of the isolation interface. Therefore, although the structure is nominally symmetric it develops lateral–torsional coupling when it is subjected to two horizontal components of ground motion. This coupling is denoted herein as accidental torsion due to overturning, and its effect in the earthquake response of nominally symmetric structures is evaluated. Several parameters are identified to control this coupling, but the most important are the slenderness of the structure and the aspect ratio of the building plan. Results are presented in terms of the torsional amplification of the deformations of the isolation base and the interstorey deformations of the superstructure. The FPS system is modelled accurately by including true large deformations and the potential uplift and impact of the isolators. Impulsive as well as subduction‐type ground motions are considered in the analysis, but results show small differences between them. An upper bound for the mean‐plus‐one standard deviation values of the torsional amplifications for the base due to this accidental torsion is 5%. This implies that for design purposes of the isolation system such increase in deformations could probably be neglected. However, the same amplification for the interstorey deformations may be as large as 50%, depending on the torsional stiffness and slenderness of the superstructure, and should be considered in design. In general, such amplification of deformations decreases for torsionally stiffer structures and smaller height‐to‐base aspect ratios. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

2.
The Friction Pendulum System (FPS) isolator is commonly used as a base isolation system in buildings. In this paper, a new tunable FPS (TFPS) isolator is proposed and developed to act as a semi‐active control system by combining the traditional FPS and semi‐active control concept. Theoretical analysis and physical tests were carried out to investigate the behavior of the proposed TFPS isolator. The experimental and theoretical results were in good agreement, both suggesting that the friction force of the TFPS isolator can be tuned to achieve seismic isolation of the structure. A series of numerical simulations of a base‐isolated structure equipped with the proposed TFPS isolator and subjected to earthquake ground motions were also conducted. In the analyses, the linear quadratic regulator (LQR) method was adopted to control the friction force of the proposed TFPS, and the applicability and effectiveness of the TFPS in controlling the structure's seismic responses were investigated. The simulation results showed that the TFPS can reduce the displacement of the isolation layer without significantly increasing the floor acceleration and inter‐story displacement of the superstructure, confirming that the TFPS can effectively control a base‐isolated structure under earthquake ground motions.  相似文献   

3.
This paper examines the effectiveness of a bilinear hysteretic base isolation system in lowering the shear forces and torques generated in a structure by two-way, translatory ground motions. The study is restricted to single-storey, three-dimensional structures having asymmetries in both horizontal directions and being excited by the El Centro (May 1940) earthquake motions. It is shown that with base isolation the structural torques are drastically reduced, even if the structural eccentricity is large. This reduction in structural torque is greatest when the isolation system's centre of stiffness coincides with the structure's centre of mass. The highly dissipative action of the isolation system provides strong modal decoupling which prevents the translational motions from resonantly driving the torsional motions. The maximum base displacements, due to both translation and rotation combined are less than 11 cm, which is well within the limits of currently available isolation system components. The dynamic action of the base isolation system is outlined and currently available isolation system components described.  相似文献   

4.
This investigation deals with the measured seismic response of a six‐storey asymmetric structural model with frictional dampers. Its main objective is to experimentally prove the concept of weak torsional balance for mass‐ and stiffness‐eccentric model configurations. The goal is to control the torsional response of these asymmetric structures and to achieve, if possible, a weak form of torsional balance by placing the so‐called empirical centre of balance (ECB) of the structure at equal distance from the edges of the building plan. The control of the dynamic response of asymmetric structures is investigated herein by using steel–teflon frictional dampers. As expected from theory, experimental results show that the mean‐square and peak displacement demand at the flexible and stiff edges of the plan may be similar in magnitude if the dampers are optimally placed. Frictional dampers have proven equally effective in controlling lateral‐torsional coupling of torsionally flexible as well as stiff structures. On the other hand, it is shown that impulsive ground motions require larger frictional capacities to achieve weak torsional balance. Copyright © 2006 John Wiley & Sons, Ltd.  相似文献   

5.
This study examines the efficacy of using seismic isolation to favorably influence the seismic response of cable‐stayed bridges subjected to near‐field earthquake ground motions. In near‐field earthquake ground motions, large amplitude spectral accelerations can occur at long periods where many cable‐stayed bridges have significant structural response modes. This combination of factors can result in large tower accelerations and base shears. In this study, lead–rubber bearing seismic isolators were modeled for three cable‐stayed bridges, and three cases of isolation were examined for each bridge. The nine isolated bridge configurations, plus three non‐isolated configurations as references, were subjected to near‐field earthquake ground motions using three‐dimensional time‐history analyses. Introduction of a small amount of isolation is shown to be very beneficial in reducing seismic accelerations and forces while at the same time producing only a modest increase in the structural displacements. There is a low marginal benefit to continue to increase the amount of isolation by further lengthening the period of the structure because structural forces and accelerations reduce at a diminishing rate whereas structural displacements increase substantially. In virtually all cases the base shears in the isolated bridges were reduced by at least 50several instances by up to 80individual near‐field records showed large variability from one record to the next, with coefficients of variation about the mean as large as 50assessing the characteristics of near‐field ground motion for use in isolation design of cable‐stayed bridges. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

6.
不对称大底板多塔楼隔震结构的地震响应分析   总被引:1,自引:0,他引:1  
党育  杜永峰 《地震学刊》2012,(4):452-458
针对不对称大底板多塔楼隔震结构体系,通过建立地震响应的动力分析简化模型,推导出不对称大底板多塔楼隔震结构体系地震作用下的运动方程。对一实际的不对称大底板多塔楼隔震结构进行地震响应仿真分析,探讨塔楼质量偏心率和塔楼质量比对结构周期比、位移比和层剪力比的影响。结果显示,不对称大底板多塔楼隔震结构扭转角主要由隔震层产生;与不隔震结构相比,不对称大底板多塔楼隔震体系的扭转角减小,可取得较好的减震效果;塔楼与底板的位置分布和质量分布会影响体系的扭转效应和减震效果,应尽量使塔楼的质心与底板质心重合,塔楼质量分布均匀,以减小结构的扭转效应,提高减震效果。  相似文献   

7.
A series of parametrically defined experimental model structures has been tested under earthquake base loading using the SERC national U.K. earthquake simulator. The models have been designed with variable ratios of torsional to lateral stiffness, and with both symmetric and asymmetric mass distributions. This paper first describes the tests carried out to determine the basic dynamic model properties and the establishment of idealized analytical models which give accurate predictions of model behaviour under steady-state loading and free-vibration conditions. Secondly, a detailed discussion is made of the two highly coupled structural models having uncoupled torsional to lateral frequency ratio Rf = 1.2, commenting on the ability of the modal analysis procedures to predict accurately the maximum recorded responses. It is concluded that the theory underestimates the significance of the fundamental torsional mode of vibration in the combined structural response, and overestimates the contribution of the first lateral mode. These effects compensate each other on the side of the structure which is most severely affected by torsional response, but produce large inaccuracies on the side of the building which is commonly assumed to be affected beneficially by torsional coupling.  相似文献   

8.
In this study friction pendulum system (FPS) bearings and precast-prestressed pile (PPP) isolators are considered as base isolation devices for a Chilean confined masonry house. The house is numerically modeled using a multiple degree-of-freedom approach that is calibrated with experimental data. Dynamic behavior of the FPS and PPP isolators is simulated using analytical formulations based on laboratory testing. Optimization of the isolators is performed using an earthquake that is generated to match the design spectrum for the house based on Chilean seismic code. A non-dominated sorting genetic algorithm (NSGA-II) is applied to carry out the optimization. Seismic response of the base-isolated structure subjected to a suite of ground motions is compared to the performance of the traditionally-constructed structure by means of several performance indices (PIs). Numerical simulations indicate that the PPP isolation system is more effective in reducing the base and structural shear, interstory drift, and floor acceleration of the structure than the FPS isolation system, although both systems result in substantial reductions of the response.  相似文献   

9.
Storage tanks are vulnerable to earthquakes, as numerous major earthquakes have demonstrated. The trend of recent revisions to make seismic design criteria for large‐scale industrial storage tanks increasingly stringent has made development of cost‐effective earthquake‐resistant design and retrofit techniques for industrial tanks imperative. This study assesses the feasibility of seismic base isolation for making liquid‐filled storage tanks earthquake resistant. The sliding‐type friction pendulum seismic (FPS) bearings are considered rather than the elastomeric bearings because the dynamic characteristics of an FPS‐isolated tank remain unchanged regardless of the storage level. This work has devised a hybrid structural‐hydrodynamic model and solution algorithm, which would permit simple, accurate and efficient assessment of the seismic response of rigid cylindrical storage tanks in the context of seismic isolation. Extensive numerical simulations confirm the effectiveness of seismic base isolation of rigid cylindrical tanks using FPS bearings. Copyright © 2001 John Wiley & Sons, Ltd.  相似文献   

10.
Different modelling aspects of structures isolated using the frictional pendulum system and subjected to earthquake ground motions are studied herein. Although the vertical dynamics of these structures is given special emphasis, other effects such as large isolator deformations and bidirectional input motion are also considered. Different structural models of the FPS are developed and tested for single-storey structures and a real four-storey building frame; among them, an ‘exact’ formulation of the FPS force–deformation constitutive relationship is presented. Results show that global building responses can be computed within 20 per cent error in the mean using a simplified model that ignores the vertical motion of the building; however, structural member deformations and forces need to be computed using a model that considers such motion. This is of particular importance when there exist correlation between the horizontal and vertical components of ground motion. Further, a physical model of the FPS is introduced and used to determine the response of a real four-storey frame, including uplift and downward impact. Results from this analysis show that local column responses may vary substantially depending on the stiffness of the isolation storey and the presence of a mass at the isolation level. Such mass is capable of filtering the large increase in column shear that results from the impact of the structure after uplift. Uplift occurs at several instants of the response of the structure considered, leading to an increase in column base shear as large as 3 times the shear obtained by ignoring the vertical dynamics of the building. © 1998 John Wiley & Sons, Ltd.  相似文献   

11.
摩擦摆基础隔震上部偏心结构地震反应影响因素分析   总被引:1,自引:0,他引:1  
对上部结构存在偏心的摩擦摆基础隔震结构进行了水平双向地震作用下的地震反应分析,研究了上部结构偏心距和抗扭刚度对结构地震反应的影响。分析表明:上部结构偏心距对上部结构和隔震层的位移反应和加速度反应均有较大影响,即使在上部结构偏心距较小时,其对结构地震反应仍有一定程度的影响;上部结构的抗扭刚度对上部结构的加速度反应影响较小,而对上部结构的位移反应影响较大;上部结构的抗扭刚度对隔震层的加速度反应和位移反应影响较小。因而,对于上部结构存在偏心的摩擦摆基础隔震结构,应减小上部结构偏心距并增大其抗扭刚度以减小摩擦摆基础隔震结构的扭转反应。  相似文献   

12.
Three analytical studies of base‐isolated structures are carried out. First, six pairs of near‐fault motions oriented in directions parallel and normal to the fault were considered, and the average of the response spectra of these earthquake records was obtained. This study shows that in addition to pulse‐type displacements, these motions contain significant energy at high frequencies and that the real and pseudo‐velocity spectra are quite different. The second analysis modelled the response of a model of an isolated structure with a flexible superstructure to study the effect of isolation damping on the performance of different isolation systems under near‐fault motion. The results show that there exists a value of isolation system damping for which the superstructure acceleration for a given structural system attains a minimum value under near‐fault motion. Therefore, although increasing the bearing damping beyond a certain value may decrease the bearing displacement, it may transmit higher accelerations into the superstructure. Finally, the behaviour of four isolation systems subjected to the normal component of each of the near‐fault motions were studied, showing that EDF type isolation systems may be the optimum choice for the design of isolated structures in near‐fault locations. Copyright © 2001 John Wiley & Sons, Ltd.  相似文献   

13.
Shake table tests on a mass eccentric model with base isolation   总被引:1,自引:0,他引:1  
A mass eccentric structure is usually more seismically vulnerable than its concentric counterpart because of the coupled torsional–translational response of such structures. In this work, dynamic characteristics and response of a five‐storey benchmark model with moderate mass eccentricity were investigated using a shake table, simulating four different ground motions. The effectiveness of laminated rubber bearings (LRB) and lead‐core rubber bearings (LCRB) in protecting eccentric structures was examined and evaluated in relation to translational and torsional responses of the benchmark model. It was observed that both translational and torsional responses were significantly reduced with the addition of either a LRB or LCRB isolated system regardless of the nature of ground motion input. The LRB were identified to be more effective than LCRB in reducing model relative displacements, the relative torsional angle as well as accelerations, and therefore provided a better protection of the superstructure and its contents. On the other hand, LCRB rendered a smaller torsional angle and absolute displacement of the base isolation system, hence a more stable structural system. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

14.
This paper concerns the design of passive base isolation systems characterized by a bilinear hysteretic behaviour. The study refers to the case where the structure to be isolated (superstructure) vibrates according to the first mode. In this case the whole isolated structure can be modelled by a two‐degree‐of‐freedom system. The base isolation effectiveness has been evaluated for different characteristics of the device, namely mass, strength, elastic and plastic stiffness, by using mainly energetic quantities. The optimum values for the base device have been obtained by minimizing the input energy and the displacement of the superstructure. Conclusions are drawn for superstructures with a fundamental period of 0.5s, a damping ratio of 5% and for three different kinds of earthquake ground motions. The study showed that the seismic input greatly affects the behaviour of the isolated structure, and therefore the design ground motion must be carefully chosen, dependent on the characteristics of the site. A simple procedure that involves mainly linear dynamic analyses is proposed for the design of base devices used in conjunction with superstructures of any fundamental vibration period. The procedure produces good results in spite of its simplicity, and therefore it is suitable for practical use by design engineers. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

15.
The paper deals with the applicability of the extended N2 method to base‐isolated plan‐asymmetric building structures. The results obtained by the usual pushover analysis of a 3D structural model are further combined with the aid of linear dynamic (spectral) analysis to account for the dynamic effects caused by structural asymmetry. In the paper, the method has been applied to the seismic analysis of a mass‐eccentric four‐storeyed RC frame building isolated with lead rubber bearings. Three different positions of the center of isolation system (CI) with respect to the center of mass (CM) and the center of stiffness of the superstructure (CS) were considered. The response was analyzed for three different eccentricities, three different torsional to lateral frequency ratios of the superstructure, and two ground motion intensities. The stiffness of the isolators was selected for three different protection levels, which resulted in elastic as well as moderately to excessively damaged superstructure performance levels. The results are presented in terms of the top, base and relative displacements, as well as the stiff/flexible side amplification factors. A more detailed insight into the nonlinear behavior of the superstructure is given in a form of ductility factors for the flexible and stiff side frames. The results of the extended N2 method for selected lateral load distributions are compared with the average results of nonlinear dynamic analyses. It was concluded that the extended N2 method could, with certain limitations, provide a reasonable prediction of the torsional influences in minor to moderately asymmetric base‐isolated structures. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

16.
In seismic base isolation, most of the earthquake‐induced displacement demand is concentrated at the isolation level, thereby the base‐isolation system undergoes large displacements. In an attempt to reduce such displacement demand, this paper proposes an enhanced base‐isolation system incorporating the inerter, a 2‐terminal flywheel device whose generated force is proportional to the relative acceleration between its terminals. The inerter acts as an additional, apparent mass that can be even 200 times higher than its physical mass. When the inerter is installed in series with spring and damper elements, a lower‐mass and more effective alternative to the traditional tuned mass damper (TMD) is obtained, ie, the TMD inerter (TMDI), wherein the device inertance plays the role of the TMD mass. By attaching a TMDI to the isolation floor, it is demonstrated that the displacement demand of base‐isolated structures can be significantly reduced. Due to the stochastic nature of earthquake ground motions, optimal parameters of the TMDI are found based on a probabilistic framework. Different optimization procedures are scrutinized. The effectiveness of the optimal TMDI parameters is assessed via time history analyses of base‐isolated multistory buildings under several earthquake excitations; a sensitivity analysis is also performed. The enhanced base‐isolation system equipped with optimal TMDI attains an excellent level of vibration reduction as compared to the conventional base‐isolation scheme, in terms not only of displacement demand of the base‐isolation system but also of response of the isolated superstructure (eg, base shear and interstory drifts); moreover, the proposed vibration control strategy does not imply excessive stroke of the TMDI.  相似文献   

17.
Curved surface sliding bearings, which are usually called as friction pendulum system (FPS) are commonly used for base isolation of liquid storage tanks since the period of the isolation system is independent of the storage level. However the restoring force and the damping at the isolation system are functions of axial load which changes during an earthquake excitation. This change might be in appreciable amounts especially for the tanks with high aspect ratios. The present paper focuses on earthquake performances of both broad and slender tanks base isolated by FPS bearings. The effects of overturning moment and vertical acceleration on axial load variation at the bearings are considered. The efficiency of the isolation system is investigated by analyzing the effects of various parameters such as; (i) isolation period, (ii) tank aspect ratio and (iii) coefficient of friction. The Haroun and Housner's three-degrees-of-freedom lumped mass model was used to solve the governing equations of motion in which convective, impulsive and rigid masses were included. A number of selected ground motions were considered and the results were compared to those of non-isolated cases.As a result, base isolation was found to be effective in reducing the base shear values for both broad and slender tanks without significantly affecting the sloshing displacements of the broad ones. The efficiency was even more pronounced for slender tanks subjected to near fault ground motions for isolation periods above 3 s. This specific value of isolation period also eliminated possible design problems arising from under-estimation of base shear values (up to 40%) due to ignoring the effects of axial load variation in lower isolation periods. Overturning effects should not be ignored especially for tanks with high aspect ratios (S) and being subjected to near fault ground motion.  相似文献   

18.
In order to mitigate the effect of torsion during earthquakes, most seismic codes of the world provide design guidelines for strength distribution based on the traditional perception that element stiffness and strength are independent parameters. Recent studies have pointed out that for an important class of widely used structural elements such as reinforced concrete flexural walls, stiffness is a strength‐dependent parameter. This implies that the lateral stiffness distribution in a wall‐type system cannot be defined prior to the assignment of elements' strength. Consequently, stiffness eccentricity cannot be computed readily and the current codified torsional provisions cannot be implemented in a straightforward manner. In this study, an alternate guideline for strength distribution among lateral force resisting elements is presented. To develop such a guideline, certain issues related to the dynamic behaviour of asymmetric wall‐type systems during a damaging earthquake were examined. It is shown that both stiffness and strength eccentricity are important parameters affecting the seismic response of asymmetric wall‐type systems. In particular, results indicate that torsional effects can be minimized by using a strength distribution that results in the location of the centre of strength CV and the centre of rigidity CR on the opposite sides of the centre of mass CM. Copyright © 2001 John Wiley & Sons, Ltd.  相似文献   

19.
An advanced analytical model for high damping rubber bearings   总被引:1,自引:0,他引:1  
Base‐isolation technologies have been developed over the years in attempts to mitigate the effects of earthquakes on structures and potentially vulnerable contents in earthquake prone areas of the world. The high damping rubber bearing (HDRB) is a relatively recent and evolving technology of this kind. The isolator shifts the fundamental period of the base‐isolated structure to a value beyond the range of the plentiful energy‐containing periods of earthquake motions and supplies significant damping to dissipate energy caused by motions. Nevertheless, the highly non‐linear mechanical behaviour of the HDRB is so complex, especially at large strains, that it is difficult to model it analytically. In this paper, an extensive study of experimental tests for identifying the mechanical characteristics of the HDRB is presented. By modifying the Wen's model to include the rate‐dependent effects, an advanced analytical model in an incremental form for the HDRB is also proposed. A very good agreement between the analytical and experimental results has been obtained. It is illustrated that the proposed mathematical model can predict well the mechanical behaviour of HDRB bearings, even at large shear strain. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   