首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 765 毫秒
1.
To limit the response of structures during external disturbances such as strong winds or large seismic events, structural control systems can be used. In the structural engineering field, attention has been shifted from active control to semi‐active control systems. Unlike active control system devices, semi‐active devices are compact, have efficient power consumption characteristics and are less expensive. As a result, an environment of a large number of actuators and sensors will result, rendering a complex large‐scale dynamic system. Such a system is best controlled by a decentralized approach such as market‐based control (MBC). In MBC, the system is modelled as a market place of buyers and sellers that leads to an efficient allocation of control power. The resulting MBC solution is shown to be locally Pareto optimal. This novel control approach is applied to three linear structural systems ranging from a one‐storey structure to a 20‐storey structure, all controlled by semi‐active hydraulic dampers. It is shown that MBC is competitive in the reduction of structural responses during large seismic loadings as compared to the centralized control approach of the linear quadratic regulation controller. Copyright © 2002 John Wiley & Sons, Ltd.  相似文献   

2.
This study examines the efficacy of using seismic isolation to favorably influence the seismic response of cable‐stayed bridges subjected to near‐field earthquake ground motions. In near‐field earthquake ground motions, large amplitude spectral accelerations can occur at long periods where many cable‐stayed bridges have significant structural response modes. This combination of factors can result in large tower accelerations and base shears. In this study, lead–rubber bearing seismic isolators were modeled for three cable‐stayed bridges, and three cases of isolation were examined for each bridge. The nine isolated bridge configurations, plus three non‐isolated configurations as references, were subjected to near‐field earthquake ground motions using three‐dimensional time‐history analyses. Introduction of a small amount of isolation is shown to be very beneficial in reducing seismic accelerations and forces while at the same time producing only a modest increase in the structural displacements. There is a low marginal benefit to continue to increase the amount of isolation by further lengthening the period of the structure because structural forces and accelerations reduce at a diminishing rate whereas structural displacements increase substantially. In virtually all cases the base shears in the isolated bridges were reduced by at least 50several instances by up to 80individual near‐field records showed large variability from one record to the next, with coefficients of variation about the mean as large as 50assessing the characteristics of near‐field ground motion for use in isolation design of cable‐stayed bridges. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

3.
This paper presents a statistical performance analysis of a semi‐active structural control system for suppressing the vibration response of building structures during strong seismic events. The proposed semi‐active mass damper device consists of a high‐frequency mass damper with large stiffness, and an actively controlled interaction element that connects the mass damper to the structure. Through actively modulating the operating states of the interaction elements according to pre‐specified control logic, vibrational energy in the structure is dissipated in the mass damper device and the vibration of the structure is thus suppressed. The control logic, categorized under active interaction control, is defined directly in physical space by minimizing the inter‐storey drift of the structure to the maximum extent. This semi‐active structural control approach has been shown to be effective in reducing the vibration response of building structures due to specific earthquake ground motions. To further evaluate the control performance, a Monte Carlo simulation of the seismic response of a three‐storey steel‐framed building model equipped with the proposed semi‐active mass damper device is performed based on a large ensemble of artificially generated earthquake ground motions. A procedure for generating code‐compatible artificial earthquake accelerograms is also briefly described. The results obtained clearly demonstrate the effectiveness of the proposed semi‐active mass damper device in controlling vibrations of building structures during large earthquakes. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

4.
The global growth in wind energy suggests that wind farms will increasingly be deployed in seismically active regions, with large arrays of similarly designed structures potentially at risk of simultaneous failure under a major earthquake. Wind turbine support towers are often constructed as thin‐walled metal shell structures, well known for their imperfection sensitivity, and are susceptible to sudden buckling failure under compressive axial loading. This study presents a comprehensive analysis of the seismic response of a 1.5‐MW wind turbine steel support tower modelled as a near‐cylindrical shell structure with realistic axisymmetric weld depression imperfections. A selection of 20 representative earthquake ground motion records, 10 ‘near‐fault’ and 10 ‘far‐field’, was applied and the aggregate seismic response explored using lateral drifts and total plastic energy dissipation during the earthquake as structural demand parameters. The tower was found to exhibit high stiffness, although global collapse may occur soon after the elastic limit is exceeded through the development of a highly unstable plastic hinge under seismic excitations. Realistic imperfections were found to have a significant effect on the intensities of ground accelerations at which damage initiates and on the failure location, but only a small effect on the vibration properties and the response prior to damage. Including vertical accelerations similarly had a limited effect on the elastic response, but potentially shifts the location of the plastic hinge to a more slender and, therefore, weaker part of the tower. The aggregate response was found to be significantly more damaging under near‐fault earthquakes with pulse‐like effects and large vertical accelerations than far‐field earthquakes without these aspects. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

5.
Centralized semi‐active control is a technique for controlling the whole structure using one main computer. Centralized control systems introduce better control for relatively short to medium high structures where the response of any story cannot be separated from the adjacent ones. In this paper, two centralized control approaches are proposed for controlling the seismic response of post‐tensioned (PT) steel frames. The first approach, the stiffness control approach, aims to alter the stiffness of the PT frame so that it avoids large dynamic amplifications due to earthquake excitations. The second approach, deformation regulation control approach, aims at redistributing the demand/strength ratio in order to provide a more uniform distribution of deformations over the height of the structure. The two control approaches were assessed through simulations of the earthquake response of semi‐actively and passively controlled six‐story post‐tensioned steel frames. The results showed that the stiffness control approach is efficient in reducing the frame deformations and internal forces. The deformation regulation control approach was found to be efficient in reducing the frame displacements and generating a more uniform distribution of the inter‐story drifts. These results indicate that centralized semi‐active control can be used to improve the seismic performance of post‐tensioned steel frames. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

6.
Considerable effort has been devoted to develop passive and active methods for reducing structural response under seismic excitations. Passive control approaches have already found application in practice. Active control methods, on the other hand, are being vigorously examined for application to civil structures. This paper investigates the application of active and semi-active control schemes to structures subjected to seismic excitations, and it focuses on the use of the sliding-mode control approach for the development of the control algorithms. The possibility of control redundancy with respect to the number of sliding constraints is taken into account in the controller design. Several sets of numerical results are obtained for a realistic 10-storey shear building, subjected to earthquake-induced ground motions and controlled by active or semi-active control schemes. It is observed that both active and semi-active control schemes can be used to reduce the dynamic response. Active control performs very effectively in reducing the structural response, but the required control force values can be quite large to limit its practical application in the case of large and massive buildings. Active regulation of linear viscous dampers was found unnecessary for this type of structural system, as it did not induce any significantly more reduction in the response than the dampers acting passively. On the other hand, it is shown that active regulation of stiffness can be used with advantage to reduce the response. © 1997 by John Wiley & Sons, Ltd.  相似文献   

7.
Analysis of civil structures at the scale of life‐cycle requires stochastic modeling of degradation. Phenomena causing structures to degrade are typically categorized as aging and point‐in‐time overloads. Earthquake effects are the members of the latter category this study deals with in the framework of performance‐based earthquake engineering (PBEE). The focus is structural seismic reliability, which requires modeling of the stochastic process describing damage progression, because of subsequent events, over time. The presented study explicitly addresses this issue via a Markov‐chain‐based approach, which is able to account for the change in seismic response of damaged structures (i.e. state‐dependent seismic fragility) as well as uncertainty in occurrence and intensity of earthquakes (i.e. seismic hazard). The state‐dependent vulnerability issue arises when the seismic hysteretic response is evolutionary and/or when the damage measure employed is such that the degradation increment probabilistically depends on the conditions of the structure at the time of the shock. The framework set up takes advantage also of the hypotheses of classical probabilistic seismic hazard analysis, allowing to separate the modeling of the process of occurrence of seismic shocks and the effect they produce on the structure. It is also discussed how the reliability assessment, which is in closed‐form, may be virtually extended to describe a generic age‐ and state‐dependent degradation process (e.g. including aging and/or when aftershock risk is of interest). Illustrative applications show the options to calibrate the model and its potential in the context of PBEE. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

8.
Ground‐motion simulations generated from physics‐based wave propagation models are gaining increasing interest in the engineering community for their potential to inform the performance‐based design and assessment of infrastructure residing in active seismic areas. A key prerequisite before the ground‐motion simulations can be used with confidence for application in engineering domains is their comprehensive and rigorous investigation and validation. This article provides a four‐step methodology and acceptance criteria to assess the reliability of simulated ground motions of not historical events, which includes (1) the selection of a population of real records consistent with the simulated scenarios, (2) the comparison of the distribution of Intensity Measures (IMs) from the simulated records, real records, and Ground‐Motion Prediction Equations (GMPEs), (3) the comparison of the distribution of simple proxies for building response, and (4) the comparison of the distribution of Engineering Demand Parameters (EDPs) for a realistic model of a structure. Specific focus is laid on near‐field ground motions (<10km) from large earthquakes (Mw7), for which the database of real records for potential use in engineering applications is severely limited. The methodology is demonstrated through comparison of (2490) near‐field synthetic records with 5 Hz resolution generated from the Pitarka et al (2019) kinematic rupture model with a population of (38) pulse‐like near‐field real records from multiple events and, when applicable, with NGA‐W2 GMPEs. The proposed procedure provides an effective method for informing and advancing the science needed to generate realistic ground‐motion simulations, and for building confidence in their use in engineering domains.  相似文献   

9.
Seismic pounding of base‐isolated buildings has been mostly studied in the past assuming unidirectional excitation. Therefore, in this study, the effects of seismic pounding on the response of base‐isolated reinforced concrete buildings under bidirectional excitation are investigated. For this purpose, a three‐dimensional finite element model of a code‐compliant four‐story building is considered, where a newly developed contact element that accounts for friction and is capable of simulating pounding with retaining walls at the base, is used. Nonlinear behavior of the superstructure as well as the isolation system is considered. The performance of the building is evaluated separately for far‐fault non‐pulse‐like ground motions and near‐fault pulse‐like ground motions, which are weighted scaled to represent two levels of shaking viz. the design earthquake (DE) level and the risk‐targeted maximum considered earthquake (MCER) level. Nonlinear time‐history analyses are carried out considering lower bound as well as upper bound properties of isolators. The influence of separation distance between the building and the retaining walls at the base is also investigated. It is found that if pounding is avoided, the performance of the building is satisfactory in terms of limiting structural and nonstructural damage, under DE‐level motions and MCER‐level far‐fault motions, whereas unacceptably large demands are imposed by MCER‐level near‐fault motions. In the case of seismic pounding, MCER‐level near‐fault motions are found to be detrimental, where the effect of pounding is mostly concentrated at the first story. In addition, it is determined that considering unidirectional excitation instead of bidirectional excitation for MCER‐level near‐fault motions provides highly unconservative estimates of superstructure demands. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

10.
Because of many advantages over other control systems, semi‐active control devices have received considerable attention for applications to civil infrastructures. A variety of different semi‐active control devices have been studied for applications to buildings and bridges subject to strong winds and earthquakes. Recently, a new semi‐active control device, referred to as the resetable semi‐active stiffness damper (RSASD), has been proposed and studied at the University of California, Irvine (UCI). It has been demonstrated by simulation results that such a RSASD is quite effective in protecting civil engineering structures against earthquakes, including detrimental near‐field earthquakes. In this paper, full‐scale hardware for RSASD is designed and manufactured using pressurized gas. Experimental tests on full‐scale RSASDs have been conducted to verify the hysteretic behaviours (energy dissipation characteristics) and the relation between the damper stiffness and the gas pressure. The correlation between the experimental results of the hysteresis loops of RASADs and that of the theoretical ones has been assessed qualitatively. Experimental results further show the linear relation between the gas pressure and the stiffness of the RSASD as theoretically predicted. Finally, shake table tests have also been conducted using an almost full‐scale 3‐storey steel frame model equipped with full‐scale RSASDs at the National Center for Research on Earthquake Engineering (NCREE), Taipei, Taiwan, and the results are presented. Experimental results demonstrate the performance of RSASDs in reducing the responses of the large‐scale building model subject to several near‐field earthquakes. Copyright © 2007 John Wiley & Sons, Ltd.  相似文献   

11.
The purpose of this paper is to investigate the ground motion characteristics of the Chi‐Chi earthquake (21 September 1999) as well as the interpretation of structural damage due to this earthquake. Over 300 strong motion records were collected from the strong motion network of Taiwan for this earthquake. A lot of near‐field ground motion data were collected. They provide valuable information on the study of ground motion characteristics of pulse‐like near‐field ground motions as well as fault displacement. This study includes: attenuation of ground motion both in PGA and spectral amplitude, principal direction, elastic and inelastic response analysis of a SDOF system subjected to near‐field ground motion collected from this event. The distribution of spectral acceleration and spectral velocity along the Chelungpu fault is discussed. Based on the mode decomposition method the intrinsic mode function of ground acceleration of this earthquake is examined. A long‐period wave with large amplitude was observed in most of the near‐source ground acceleration. The seismic demand from the recorded near‐field ground motion is also investigated with an evaluation of seismic design criteria of Taiwan Building Code. Copyright © 2000 John Wiley & Sons, Ltd.  相似文献   

12.
The concept of the hybrid passive control system is studied analytically by investigating the seismic response of steel frame structures. Hybrid control systems consist of two different passive elements combined into a single device or system. The hybrid systems investigated in this research consist of a rate‐dependent damping device paired with a rate‐independent energy dissipation element. The innovative configurations exploit individual element strengths and offset their weaknesses through multiphased behavior. A nine‐story, five‐bay steel moment‐frame was used for the analysis. Six different seismic resisting systems were analyzed and compared. The conventional systems included a special moment‐resisting frame (SMRF) and a dual SMRF–buckling‐restrained brace (BRB) system. The final four configurations are hybrid passive systems. The different hybrid configurations utilize a BRB and either a high‐damping rubber damper or viscous fluid damper. The analyses were run in the form of an incremental dynamic analysis. Several damage measures were calculated, including maximum roof drift, base shear, and total roof acceleration. The results demonstrate the capability of hybrid passive control systems to improve structural response compared with conventional lateral systems and to be effective for performance‐based seismic design. Each hybrid configuration improved some aspect of structural response with some providing benefits for multiple damage measures. The multiphased nature provides improved response for frequent and severe seismic events. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

13.
Passive and semi‐active tuned mass damper (PTMD and SATMD) building systems are proposed to mitigate structural response due to seismic loads. The structure's upper portion self plays a role either as a tuned mass passive damper or a semi‐active resetable device is adopted as a control feature for the PTMD, creating a SATMD system. Two‐degree‐of‐freedom analytical studies are employed to design the prototype structural system, specify its element characteristics and effectiveness for seismic responses, including defining the resetable device dynamics. The optimal parameters are derived for the large mass ratio by numerical analysis. For the SATMD building system the stiffness of the resetable device design is combined with rubber bearing stiffness. From parametric studies, effective practical control schemes can be derived for the SATMD system. To verify the principal efficacy of the conceptual system, the controlled system response is compared with the response spectrum of the earthquake suites used. The control ability of the SATMD scheme is compared with that of an uncontrolled (No TMD) and an ideal PTMD building systems for multi‐level seismic intensity. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

14.
Non‐linear dynamic time‐history analyses conducted as part of a performance‐based seismic design approach often require that the ground motion records are scaled to a specified level of seismic intensity. Recent research has demonstrated that certain ground motion scaling methods can introduce a large scatter in the estimated seismic demands. The resulting demand estimates may be biased, leading to designs with significant uncertainty and unknown margins of safety, unless a relatively large ensemble of ground motion records is used. This paper investigates the effectiveness of seven ground motion scaling methods in reducing the scatter in estimated peak lateral displacement demands. Non‐linear single‐degree‐of‐freedom systems and non‐linear multi‐degree‐of‐freedom systems are considered with different site conditions (site soil profile and epicentral distance) and structural characteristics (yield strength, period, and hysteretic behavior). It is shown that scaling methods that work well for ground motions representative of stiff soil and far‐field conditions lose their effectiveness for soft soil and near‐field conditions for a wide range of structural characteristics. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

15.
This paper presents the feasibility of using an impedance‐based health monitoring technique in monitoring a critical civil facility. The objective of this research is to utilize the capability of the impedance method in identifying structural damage in those areas where a very quick condition monitoring is urgently needed, such as in a post‐earthquake analysis of a pipeline system. The basic principle behind this technique is to utilize high‐frequency structural excitation (typically greater than 30 kHz) through surface‐bonded piezoelectric sensors/actuators to detect changes in structural point impedance due to the presence of damage. Real‐time damage detection in pipes connected by bolted joints was investigated, and the capability of the impedance method in tracking and monitoring the integrity of the typical civil facility has been demonstrated. Data collected from the tests illustrates the capability of this technology to detect imminent damage under normal operating conditions and immediately after a natural disaster. Copyright © 2001 John Wiley & Sons, Ltd.  相似文献   

16.
To better understand (and correct for) the factors affecting the estimation of attenuation (Q), we simulate subsurface wave propagation with the Weyl/Sommerfeld integral. The complete spherical wavefield emanating from a P‐wave point source surrounded by a homogeneous, isotropic and attenuative medium is thus computed. In a resulting synthetic vertical seismic profile, we observe near‐field and far‐field responses and a 90° phase rotation between them. Depth dependence of the magnitude spectra in these two depth regions is distinctly different. The logarithm of the magnitude spectra shows a linear dependence on frequency in the far‐field but not in those depth regions where the near‐field becomes significant. Near‐field effects are one possible explanation for large positive and even negative Q‐factors in the shallow section that may be estimated from real vertical seismic profile data when applying the spectral ratio method. We outline a near‐field compensation technique that can reduce errors in the resultant Q estimates.  相似文献   

17.
Considerable effort has been devoted to develop optimal control methods for reducing structural response under seismic forces. In this study analytical solution of the linear regulator problem applied widely to the control of earthquake‐excited structures is obtained by using the sufficient conditions of optimality even though almost all of the optimal controls proposed previously for structural control are based on the necessary conditions of optimality. Since the resulting optimal closed–open‐loop control cannot be implemented for civil structures exposed to earthquake forces, the solution of the optimal closed–open‐loop control is carried out approximately based on the prediction of the seismic acceleration values in the near future. Upon obtaining the relation between the exact optimal solution and future values of seismic accelerations, it is shown numerically that the solution of the optimal closed–open‐loop control problem can be performed approximately by using only the first few predicted seismic acceleration values if a given norm criteria is satisfied. Calculated performance measures indicate that the suggested approximate solution is better than the closed‐loop control and as we predict the future values of the excitation more accurately, it will approach the optimal solution. Copyright © 2001 John Wiley & Sons, Ltd.  相似文献   

18.
This paper presents a family of semi‐active control algorithms termed as active interaction control (AIC) used for seismic response control of civil structures. AIC control algorithms include active interface damping (AID), optimal connection strategy (OCS) and tuned interaction damping (TID). A typical SDOF AIC system consists of a primary structure, an auxiliary structure and an interaction element. The auxiliary structure typically has stiffness comparable to that of the primary structure while its natural frequency is much higher than that of the primary structure. Interactions between the primary and the auxiliary structures are defined by specific AIC control logic such that vibrational energy is extracted from the primary structure into the auxiliary structure during a locking phase and dissipated in the auxiliary structure in the subsequent unlocking phase. The stability of AIC control algorithms is shown using the Lyapunov direct method. The efficacy of AIC control algorithms is demonstrated by the results of numerical simulations of SDOF systems subjected to seismic ground motions. Practical issues such as sampling period and time delay are also investigated in this study. Copyright © 2001 John Wiley & Sons, Ltd.  相似文献   

19.
China is a country where 100% of the territory is located in a seismic zone. Most of the strong earthquakes are over prediction. Most fatalities are caused by structural collapse. Earthquakes not only cause severe damage to structures, but can also damage non-structural elements on and inside of facilities. This can halt city life, and disrupt hospitals, airports, bridges, power plants, and other infrastructure. Designers need to use new techniques to protect structures and facilities inside. Isolation, energy dissipation and, control systems are more and more widely used in recent years in China. Currently, there are nearly 6,500 structures with isolation and about 3,000 structures with passive energy dissipation or hybrid control in China. The mitigation techniques are applied to structures like residential buildings, large or complex structures, bridges, underwater tunnels, historical or cultural relic sites, and industrial facilities, and are used for retrofitting of existed structures. This paper introduces design rules and some new and innovative devices for seismic isolation, energy dissipation and hybrid control for civil and industrial structures. This paper also discusses the development trends for seismic resistance, seismic isolation, passive and active control techniques for the future in China and in the world.  相似文献   

20.
Semi‐active dampers offer significant capability to reduce dynamic wind and seismic structural response. A novel resetable device with independent valve control laws that enables semi‐active re‐shaping of the overall structural hysteretic behaviour has been recently developed, and a one‐fifth scale prototype experimentally validated. This research statistically analyses three methods of re‐shaping structural hysteretic dynamics in a performance‐based seismic design context. Displacement, structural force, and total base‐shear response reduction factor spectra are obtained for suites of ground motions from the SAC project. Results indicate that the reduction factors are suite invariant. Resisting all motion adds damping in all four quadrants and showed 40–60% reductions in the structural force and displacement at the cost of a 20–60% increase in total base‐shear. Resisting only motion away from equilibrium adds damping in quadrants 1 and 3, and provides reductions of 20–40%, with a 20–50% increase in total base‐shear. However, only resisting motion towards equilibrium adds damping in quadrants 2 and 4 only, for which the structural responses and total base‐shear are reduced 20–40%. The spectral analysis results are used to create empirical reduction factor equations suitable for use in performance based design methods, creating an avenue for designing these devices into structural applications. Overall, the reductions in both response and base‐shear indicate the potential appeal of this semi‐active hysteresis sculpting approach for seismic retrofit applications—largely due to the reduction of the structural force and overturning demands on the foundation system. Copyright © 2006 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号