首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Field Test of the In Situ Permeable Ground Water Flow Sensor   总被引:1,自引:0,他引:1  
Two in situ permeable flow sensors, recently developed at Sandia National Laboratories, were field tested at the Brazos River Hydrologic Field Site near College Station, Texas. The flow sensors use a thermal perturbation technique to quantify the magnitude and direction of ground water flow in three dimensions. Two aquifer pumping tests lasting eight and 13 days were used to field test the flow sensors. Components of ground water flow as determined from piezometer gradient measurements were compared with ground water flow components derived from the 3-D flow sensors. The changes in velocity magnitude and direction of ground water flow induced by the pump were evaluated using flow sensor data and piezometric analyses. Flow sensor performance closely matched piezometric analysis results. Ground water flow direction (azimuth), as measured by the flow sensors and derived in the piezometric analysis, predicted the position of the pumping well accurately. Ground water flow velocities measured by the flow sensors compared well to velocities derived in the piezometric analysis. A significant delay in flow sensor response to relatively rapid changes in ground water flow was observed. Preliminary tests indicate that the in situ permeable flow sensor provides accurate and timely information on the velocity magnitude and direction of ground water flow.  相似文献   

2.
The spatial distributions of electric fields and currents in the Earth’s atmosphere are calculated. Electric potential distributions typical of substorms and quiet geomagnetic conditions are specified in the ionosphere. The Earth is treated as a perfect conductor. The atmosphere is considered as a spherical layer with a given height dependence of electrical conductivity. With the chosen conductivity model and an ionospheric potential of 300 kV with respect to the Earth, the electric field near the ground is vertical and reaches 110 Vm−1. With the 60-kV potential difference in the polar cap of the ionosphere, the electric field disturbances with a vertical component of up to 13 V m−1 can occur in the atmosphere. These disturbances are maximal near the ground. If the horizontal scales of field nonuniformity are over 100 km, the vertical component of the electric field near the ground can be calculated with the one-dimensional model. The field and current distributions in the upper atmosphere can be obtained only from the three-dimensional model. The numerical method for solving electrical conductivity problems makes it possible to take into account conductivity inhomogeneities and the ground relief.  相似文献   

3.
Effect of tilt on strong motion data processing   总被引:5,自引:2,他引:5  
In the near-field of an earthquake the effects of the rotational components of ground motion may not be negligible compared to the effects of translational motions. Analyses of the equations of motion of horizontal and vertical pendulums show that horizontal sensors are sensitive not only to translational motion but also to tilts. Ignoring this tilt sensitivity may produce unreliable results, especially in calculations of permanent displacements and long-period calculations. In contrast to horizontal sensors, vertical sensors do not have these limitations, since they are less sensitive to tilts. In general, only six-component systems measuring rotations and accelerations, or three-component systems similar to systems used in inertial navigation assuring purely translational motion of accelerometers can be used to calculate residual displacements.  相似文献   

4.
The pipe microphone has been shown to be an effective means for monitoring bedload transport in mountain streams. It is commonly installed perpendicular to the flow direction on a stable river bed, such as that of a check dam. Acoustic pulses caused by bedload collisions with the pipe are detected by a microphone. However, bedload particles saltating over the pipe remain undetected. To overcome this disadvantage, we installed a horizontal as well as a vertical pipe microphone in the Ashi‐arai‐dani supercritical channel located in the Hodaka mountain range, Japan. The vertical pipe was installed on the wall of the channel and the horizontal pipe was installed on the channel bed. The acoustic response of the horizontal pipe is expected to be larger than that of the vertical pipe, because the bedload concentration decreases with increasing height above the bed. However, at high amplifications, the peak pulse value from the vertical pipe is higher than that from the horizontal pipe. We explain this observation as follows: under high bedload discharge conditions, the pulses of the horizontal pipe are saturated but those of the vertical pipe are not. We proposed a ratio (Rhv) between the pulses detected by these sensors, and applied this ratio for calibrating the contemporaneous pulses detected by a microphone located immediately upstream of a bedload slot sampler. Indeed the Rhv‐corrected pulses correlated well with the bedload discharge calculated from the sampler, supporting our explanation. We conclude that bedload monitoring using concomitant vertical and horizontal pipe microphones can be used to calibrate centrally located pipe microphones when the bedload concentration is approximately homogeneous laterally across the width of the channel cross‐section, and thereby represent bedload discharges more accurately than with only a single pipe microphone. Copyright © 2017 John Wiley & Sons, Ltd.  相似文献   

5.
The Russian electrodynamic seismometer model S-5-S has been adapted for the measurement of rotational ground motion. The mechanical system of the original S-5-S seismometer consists of electrodynamic sensing and damping transducer coils mounted on an asymmetrical double-arm pendulum. This pendulum is suspended on a footing using two pairs of crossed flat springs, which operate as the axis of rotation. The pendulum is stabilised by an additional spring. The S-5-S can be used either as a vertical or as a horizontal sensor. The adaptation of the S-5-S seismometer described below involves removal of the additional spring and installation of an additional mass on the damping arm. Strain gauge angle sensors are installed on one pair of the crossed flat springs. The main dynamic parameters of the rotational seismometer created in this way, i.e. the natural period and damping, are controlled electronically by feedback currents proportional to the angular displacement and angular velocity, both fed to the damping transducer coil. This new seismometer, named the S-5-SR, enables measurement of the rotational component of ground motion around the horizontal or the vertical axes. The output signal from this S-5-SR seismometer can be proportional either to rotational displacement or rotational velocity.  相似文献   

6.
We built a five-component (5C) land seismic sensor that measures both the three-component (3C) particle acceleration and two vertical gradients of the horizontal wavefield through a pair of 3C microelectromechanical accelerometers. The sensor is a small cylindrical device planted vertically just below the earth's surface. We show that seismic acquisition and processing 5C sensor data has the potential to replace conventional seismic acquisition with analogue geophone groups by single 5C sensors placed at the same station interval when combined with a suitable aliased ground roll attenuation algorithm. The 5C sensor, therefore, allows for sparser, more efficient, data acquisition. The accuracy of the 5C sensor wavefield gradients depends on the 3C accelerometers, their sensitivity, self-noise and their separation. These sensor component specifications are derived from various modelling studies. The design principles of the 5C sensor are validated using test data from purpose-built prototypes. The final prototype was constructed with a pair of 3C accelerometers separated by 20 cm and with a self-noise of 35 ng Hz−1/2. Results from a two-dimensional seismic line show that the seismic image of 5C sensor data with ground roll attenuated using 5C sensor gradient data was comparable to simulated analogue group data as is the standard in the industry. This field example shows that up to three times aliased ground roll was attenuated. The 5C sensor also allows for correcting vertical component accelerometer data for sensor tilt. It is shown that a vertical component sensor that is misaligned with the vertical direction by 10° introduces an error in the seismic data of around –20 dB with respect to the seismic signal, which can be fully corrected. Advances in sensor specifications and processing algorithms are expected to lead to even more effective ground roll attenuation, enabling a reduction in the receiver density resulting in a smaller number of sensors that must be deployed and, therefore, improving the operational efficiency while maintaining image quality.  相似文献   

7.
Reactive barriers are passive and in situ ground water treatment systems. Heterogeneities in hydraulic conductivity (K) within the aquifer-reactive barrier system will result in higher flux rates, and reduced residence times, through portions of the barrier. These spatial variations in residence time will affect the treatment capacity of the barrier. A numerical flow model was used to evaluate the effects of spatial variations in K on preferential flow through barriers. The simulations indicate that the impact of heterogeneities in K will be a function of their location and distribution; the more localized the high K zone, the greater the preferential flow. The geometry of the reactive barrier will also strongly influence flow distribution. Aquifer heterogeneities will produce greater preferential flow in thinner barriers compared to thicker barriers. If the barrier K is heterogeneous, greater preferential flow will occur in thicker barriers. The K of the barrier will affect the flow distribution; decreasing the K of the barrier can result in more even distribution of flow. Results indicate that less variable flow will be attained utilizing thicker, homogeneous barriers. The addition of homogeneous zones to thinner barriers will be effective at redistributing flow only if installed immediately adjacent to both the up- and downgradient faces of the barrier.  相似文献   

8.
For many scientific and practical tasks, it is important to estimate the soil–water percolation fluxes. This paper builds on measurements with large horizontal time‐domain reflectometry water content sensors in a loamy Mollisol. The sensors were installed into pre‐drilled holes and the gaps between them, and the soil was filled with a slurry of local soil with water. This gave rise to envelopes around them that contained artificial macropores. The sensors reacted to intensive rains by a rapid increase of their readings, often above the native soil's porosity, followed by an almost equally rapid decrease. The paper explores the feasibility of quantifying the rapid percolation, based on these anomalous water content peaks, and demonstrates that this is possible in principle, if the processes are simulated by a suitable model. A two‐dimensional dual porosity non‐equilibrium (mobile‐immobile) model was tried. The envelope around the sensor was modelled as an annulus with higher porosity and hydraulic conductivity, which attracts preferential flow and amplifies the percolation signal. With the model at hand, the flux hydrographs can be derived from model simulations and measured precipitation. For contrast, the Durner equilibrium dual porosity model was tried but was found little suitable. However, even the mobile‐immobile model did not perform perfectly. Simulated water contents were similar to the measured ones at some depths but not in the others, and the percolation fluxes were overestimated, compared to cumulative soil–water balance. Efforts to improve model performance were not successful. Hence, the model structure needs to be improved. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

9.
The in situ vertical circulation column (ISVCC) is a cylindrical containment system consisting of an instrumented steel cylinder used for experimental ground water studies in sandy aquifers. Vertical flow is imposed inside the ISVCC. Although vertical wells are an option, the ISVCC installed in the Borden Aquifer is instrumented with horizontal wells and monitoring ports to avoid creating vertical preferential flow paths. The cylinder was driven downward into the aquifer using a small backhoe equipped with a vibrating plate. The ISVCC penetrates the 2.3-m-thic sand aquifer and is keyed 20 cm into the underlying clay aquitard. The cylinder was installed inside a 2 m X 2 m steel sheet pile enclosure so that the enclosed segment of aquifer could be conveniently dewatered and then excavated to allow installation of the horizontal wells. The dispersivity of the column was comparable to literature values for long sand-packed laboratory columns.
Pure phase DNAPL (tetrachloroethene and 1,1,1-trichloroethane) was slowly pumped into two ports in the center of the column. Following this DNAPL injection, an aqueous solution of vitamin B12 and reduced titanium was circulated through the column to promote degradation of the solvents. Processes observed in the ISVCC included DNAPL distribution, dissolution, and degradation, and geochemical evolution of the aquifer.
The ISVCC provides a convenient means for testing in situ technologies in the experimental stage or for selection of proven technologies to find the most effective at a specific site. It is inexpensive, easy to install, and maximizes control over flow distribution in a heterogeneous aquifer. Its application will be restricted where low hydraulic conductivity beds are present in the aquifer.  相似文献   

10.
Knickpoints in bedrock streams are often interpreted as transient features generated by a change in boundary conditions. It is typically assumed that knickpoints propagate upstream with constant vertical velocities, though this relies on a stream being in erosional steady state (erosion rate equals rock uplift rate) prior to the knickpoint's formation. Recent modeling and field studies suggest that along-stream contrasts in rock erodibility perturb streams from erosional steady state. To evaluate how contrasts in rock erodibility might impact knickpoint interpretations, we test parameter space (rock erodibility, rock contact dip angle, change in rock uplift rate) in a one-dimensional (1D) bedrock stream model that has variable rock erodibility and produces a knickpoint with a sudden change in rock uplift rate. Upstream of a rock contact, the vertical velocity of a knickpoint generated by a change in rock uplift rate is strongly correlated with how the rock contact has previously perturbed erosion rates. These knickpoints increase vertical velocity upon propagating upstream of a hard over soft contact and decrease vertical velocity upon propagating upstream of a soft over hard contact. However, interactions with other transient perturbations produced by rock contacts make for nuances in knickpoint behavior. Rock contacts also influence the geometry of knickpoints, which can become particularly difficult to identify upstream of soft over hard rock contacts. Using our simulations, we demonstrate how a contact's along-stream horizontal migration rate and cross-contact change in rock strength control how much an upstream reach is perturbed from erosional steady state. When simulations include multiple contacts, the knickpoint is particularly prone to colliding with other transient perturbations and can even disappear altogether if rock contact dips are sufficiently shallow. Caution should be taken when analyzing stream profiles in areas with significant changes in rock strength, especially when rock contact dip angles are near the stream's slope.  相似文献   

11.
Over 700 accelerograms recorded from 12 earthquakes in northeast Taiwan have been analysed for investigating the behaviour of the vertical and horizontal peak and spectral ground motion in the near-source region. Pseudo-relative spectral velocities (PSV), at 5 per cent critical damping for 23 frequencies in the range of engineering interest have been subjected to non-linear regression procedures in terms of magnitude and hypocentral distance. Predicted response spectra for several discrete distances and magnitudes are presented. The results show that the shape of response spectra for both vertical and horizontal components of ground motion is magnitude- as well as distance-dependent. The 2/3 ratio of vertical to horizontal ground motion, commonly used in engineering applications, appears unconservative in the very near field for high frequency ground motion. However, it falls below 1/2 at distances greater than 50 km. The same ratio for peak ground velocity (PGV) and peak ground displacement (PGD) tends to increase with distance—the latter at a faster rate.  相似文献   

12.
采用Yoshimitsu Okada及Steketee的断裂位错模型和汶川地震现有成果,通过坐标转换和合成矢量的方法将断裂位错模型用于映秀—北川断裂、灌县—安县断裂和北川—青川断裂组成的断裂系统的错动研究中,理论上计算龙门山近断裂地区的水平位移场(包括沿走向和垂直走向方向)和垂直位移场从震源到地表的分布.模型参数源于现有的研究成果和野外实地考察,计算得到的地表位移场与先前研究成果,包括GPS实测数据,具有的近似性表明了模型的正确性.但GPS只能测定地表水平和垂直变形,对于地下变形情况及其分布却无法描述;目前对于地下变形的研究主要基于对大量仪器记录的地震资料进行反演或通过野外观测进行推测;但是反演多集中于空间较大范围,这样虽可阐述断裂运动引起的大范围位移趋势,而对于震源附近空间介质位移的描述却略显粗糙;同时,野外观测误差较大.本文通过理论模型计算汶川地震中近断裂区域(距断裂50km)内的位移及分布.由计算发现在近断裂区域内垂直位移场和垂直走向方向位移场变化趋势一样,幅值都是从震源到地表逐渐减小;沿断裂走向方向的水平位移场从震源到地表逐渐变大,同时计算还表明位移场的变化在断裂上盘比下盘剧烈,余震分布主要集中于断裂上盘,这说明余震分布和位移剧烈程度存在某种相关性.  相似文献   

13.
We propose an improvement of the overland‐flow parameterization in a distributed hydrological model, which uses a constant horizontal grid resolution and employs the kinematic wave approximation for both hillslope and river channel flow. The standard parameterization lacks any channel flow characteristics for rivers, which results in reduced river flow velocities for streams narrower than the horizontal grid resolution. Moreover, the surface areas, through which these wider model rivers may exchange water with the subsurface, are larger than the real river channels potentially leading to unrealistic vertical flows. We propose an approximation of the subscale channel flow by scaling Manning's roughness in the kinematic wave formulation via a relationship between river width and grid cell size, following a simplified version of the Barré de Saint‐Venant equations (Manning–Strickler equations). The too large exchange areas between model rivers and the subsurface are compensated by a grid resolution‐dependent scaling of the infiltration/exfiltration rate across river beds. We test both scaling approaches in the integrated hydrological model ParFlow. An empirical relation is used for estimating the true river width from the mean annual discharge. Our simulations show that the scaling of the roughness coefficient and the hydraulic conductivity effectively corrects overland flow velocities calculated on the coarse grid leading to a better representation of flood waves in the river channels.  相似文献   

14.
Ground water temperatures in the fractured volcanic aquifer near Yucca Mountain, Nevada, have previously been shown to have significant spatial variability with regions of elevated temperatures coinciding roughly with near-vertical north-south trending faults. Using insights gained from one-dimensional models, previous investigators have suggested upwelling along faults from an underlying aquifer as a likely explanation for this ground water temperature pattern. Using a three-dimensional coupled flow and heat-transport model, we show that the thermal high coinciding with the Paintbrush fault zone can be explained without significant upwelling from the underlying aquifer. Instead, the thermal anomaly is consistent with thermal conduction enhanced slightly by vertical ground water movement within the volcanic aquifer sequence. If more than approximately 400 m3/day of water enters the volcanic aquifer from below along a 10 km fault zone, the calculated temperatures at the water table are significantly greater than the measured temperatures. These results illustrate the potential limitations in using one-dimensional models to interpret ground water temperature data, and underscore the value in combining temperature data with fully coupled three-dimensional simulations.  相似文献   

15.
High-permeability layers for remediation of ground water; go wide, not deep   总被引:3,自引:0,他引:3  
A nitrate-reactive porous media layer comprising wood particles with very high hydraulic conductivity (K approximately 1 cm/s) was used to successfully treat nitrate in a shallow sand-and-gravel aquifer in southern Ontario. Nitrate concentrations of 1.3 to 14 mg/L as N in the aquifer were attenuated to <0.5 mg/L as N in the reactive layer. Borehole dilution testing indicated that ground water velocities in the reactive layer, although variable, averaged five times higher than in the surrounding aquifer, suggesting that the layer was capturing ground water flow from deeper in the aquifer. The use of high-K reactive media opens up the possibility of installing permeable reactive barriers as horizontal layers in the shallow water table zone that do not necessarily have to penetrate the full depth of a contaminant plume to be effective. Model simulations show that the depth of capture of a high-K layer increases as the layer width in the direction of flow increases. Shallower emplacement could decrease barrier costs at some sites.  相似文献   

16.
The concept of equivalent freshwater head was adapted to predict the conditions under which density‐driven flow would adversely impact measured groundwater velocities using point velocity probes (PVPs). Theoretically, vertical flow will result from any density contrast between the PVP tracer and the groundwater. However, laboratory testing of tracers with salinities ranging from 0 to 2000 mg NaCl/L showed that horizontal velocities could be determined with good accuracy with up to 60% of the total flow being vertical due to density effects in a gravel medium. The available data suggest that density effects are less likely to be pronounced in sandy sediments. The relative amount of vertical flow due to tracer density can be estimated from vertical and horizontal velocities measured with PVPs, or from the ratio of vertical to horizontal hydraulic gradients. The equivalent freshwater gradient produced from a given tracer salinity at 10 °C (a typical groundwater temperature at moderate latitudes) can be estimated from 7.80 × 10?7 × (MNaCl), where MNaCl is the mass of NaCl added, in mg, to 1 L of site groundwater in the mixing of the tracer. Equations for other temperatures were also determined.  相似文献   

17.
A new method was developed for analysing and delineating streambed water fluxes, flow conditions and hydraulic properties using coiled fibre‐optic distributed temperature sensing or closely spaced discrete temperature sensors. This method allows for a thorough treatment of the spatial information embedded in temperature data by creating a matrix visualization of all possible sensor pairs. Application of the method to a 5‐day field dataset reveals the complexity of shallow streambed thermal regimes. To understand how velocity estimates are affected by violations of assumptions of one‐dimensional, saturated, homogeneous flow and to aid in the interpretation of field observations, the method was also applied to temperature data generated by numerical models of common field conditions: horizontal layering, presence of lateral flow and variable streambed saturation. The results show that each condition creates a distinct signature visible in the triangular matrices. The matrices are used to perform a comparison of the behaviour of one‐dimensional analytical heat‐tracing models. The results show that the amplitude ratio‐based method of velocity calculation leads to the most reliable estimates. The minimum sensor spacing required to obtain reliable velocity estimates with discrete sensors is also investigated using field data. The developed method will aid future heat‐tracing studies by providing a technique for visualizing and comparing results from fibre‐optic distributed temperature sensing installations and testing the robustness of analytical heat‐tracing models. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

18.
采用偏心状态下柱状成层各向异性(横向各向同性)介质中并矢Green函数的解析表达式高效模拟多分量感应测井仪器在井眼中偏心时的响应.为提高精度,在模拟时考虑到了金属心轴、绝缘保护层的存在以及各分量线圈系的具体形状.数值模拟结果表明,当井眼内钻井液电导率相对较高、地层电导率相对较低时,偏心对仪器响应的影响较大,尤其是对短线圈距线圈系的影响更为明显,必须进行偏心效应校正.当钻井液电导率相对较低时,偏心对线圈系响应的影响可忽略不计.对位于相对低电导率井眼中的线圈系而言仪器方位角的影响可忽略不计,而当线圈系位于相对高电导率井眼中时仪器方位角的影响极为明显.当仪器偏心率较小时线圈系的响应随仪器方位角的变化较小,仪器偏心率越大线圈系的响应随仪器方位角的变化越明显.  相似文献   

19.
A hybrid control platform is investigated in this paper to mitigate microvibrations to a group of vibration-sensitive equipment installed in a microelectronics facility subject to nearby road vehicle-induced horizontal and vertical ground motions. The hybrid control platform, on which microelectronics equipment is installed, is mounted on a building floor through a series of passive mounts and controlled by hydraulic actuators in both horizontal and vertical directions. The control platform is an elastic body with significant bending modes of vibration, and a sub-optimal control algorithm is used to manipulate the hydraulic actuators with actuator dynamics included. The finite element model and the equations of motion of the coupled platform-building system are then established in the absolute coordinate to facilitate the feedback control and performance evaluation of the platform. The horizontal and vertical ground vibrations at the base of the building induced by nearby moving road vehicles are assumed to be stationary random processes. A typical three-story microelectronics building is selected as a case study. The case study shows that the vertical vibration of the microelectronics building is higher than the horizontal. The use of a hybrid control platform can effectively reduce both horizontal and vertical microvibrations of the microelectronics equipment to the level which satisfies the stringent microscale velocity requirement specified in the Bolt Beranek & Newman (BBN) criteria.  相似文献   

20.
Radar determination of the spatial structure of hydraulic conductivity   总被引:2,自引:0,他引:2  
Spatial variability of hydraulic conductivity exerts a predominant control on the flow of fluid through porous media. Heterogeneities influence advective pathways, hydrodynamic dispersion, and density-dependent dispersion; they are, therefore, a key concern for studies of ground water resource development, contaminant transport, and reservoir engineering. Ground-penetrating radar contributes to the remote, geophysical characterization of the macroscale variability of natural porous media. On a controlled excavation of a glacial-fluvial sand and gravel deposit in the Fanshawe Delta area (Ontario, Canada), the hydraulic conductivity field of a 45 x 3 m vertical exposure was characterized using constant-head permeameter measurements performed on undisturbed horizontal sediment cores. Ground-penetrating radar data were collected along the excavation face in the form of both reflection and common midpoint surveys. Comparison of geostatistical analyses of the permeameter measurements and the radar data suggests thatthe horizontal correlation structure of radar stack velocity can be used to directly infer the horizontal correlation structure of hydraulic conductivity. The averaging nature of the common midpoint survey is manifest in the vertical correlation structure of stack velocity, making it less useful. Radar reflection data do not exhibit a spatial structure similar to that of hydraulic conductivity possibly because reflections are a result of material property contrasts rather than the material properties themselves.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号