1.
This report describes the location, collection, preparation, mineralogy, homogeneity testing, and interlaboratory certification program of a diorite gneiss reference material, SY-4. This work was an undertaking of the Canadian Certified Reference Materials Project (CCRMP). SY-4 has been certified for 49 whole-rock, minor, and trace elements. Eight additional constituents have been provisionally certified and information ranges are reported for another 14 elements.  相似文献   

2.
Analytical data on samples SY-2, SY-3 and MRG-1, reported since preparation of an earlier report, are presented, and "usable values" for the concentrations of a number of additional constituents are derived. Improved values are also derived for some of the constituents where insufficient data were available in the preceding compilation.  相似文献   

3.
An extensively modified combustion/iodometric titration method was used for the determination of sulfur in SY-2, a CANMET international rock reference material, in coarse-grained mantle rocks and glassy materials at the microgram level. Replicate analysis (n = 27) of SY-2 demonstrated the potential for this sample to be certified as a reference sample for S. Our mean sulfur concentration (122 ± 3 μg g-1) suggests that the recommended value (0.011% w/w) could underestimate the true value by 10%. The other results compare well with those generated by other more sophisticated techniques such as X-ray fluorescence spectrometry and electron probe microanalysis, whether S is dissolved in glassy materials or occurs as discrete sulfides.  相似文献   

4.
Concentration data on up to 82 individual constituents in USGS Basalt BCR-1 have been collected from 1395 journal articles and technical reports. These data are summarized in consensus (mean) values with uncertainties expressed as ± one standard deviation. Mean values are also calculated as a function of analytical procedure and all raw data are given in the tables. Recommended values are proposed based upon data criteria used by NIST (National Institute of Standards and Technology, formerly the National Bureau of Standards or NBS).  相似文献   

5.
Concentration data on 73 individual constituents in United States Geological Survey (USGS) Geochemical Exploration Reference Materials GXR-1 to GXR-6 have been collected from 131 journal articles and technical reports. These data are summarized as consensus (mean) values with uncertainties expressed as one standard deviation. Mean values are also calculated as a function of analytical procedure and all raw data are given in the tables. Recommended values are proposed based upon data criteria used by NIST (National Institute of Standards and Technology, formerly the National Bureau of Standards or NBS).  相似文献   

6.
Concentration data on up to 90 individual constituents in USGS AGV-1, GSP-1, and G-2 have been collected from 1270 journal articles and technical reports. These data are summarized in consensus (mean) values with uncertainties expressed as +/- one standard deviation. Mean values are also calculated as a function of analytical procedure and all raw data are given in the tables. Recommended values are proposed based upon data criteria used by NIST (National Institute of Standards and Technology, formerly the National Bureau of Standards or NBS).  相似文献   

7.
Concentration data on 74 individual constituents in CCRMP (Canadian Certified Reference Materials Project) soils SO-1, SO-2, SO-3, and SO-4 have been collected from 83 journal articles and technical reports. These data are summarized in consensus (mean) values with uncertainties expressed as one standard deviation. Mean values are also calculated as a function of analytical procedure and all raw data are given in the tables. Recommended values are proposed based upon data criteria used by NIST (National Institute of Standards and Technology, formerly the National Bureau of Standards or NBS).  相似文献   

8.
Using a recently published compilation of analytical data on reference samples SY-2, SY-3 and MRG-1 as an example, a case is presented in favor of more precise terminology in describing analytical methods used in reporting data in collaborative programs. The technique of final measurement in a particular method is often less important than earlier operations, such as sample attack or technique of separation.  相似文献   

9.
Concentration data on up to 91 individual constituents in USGS DTS-1, G-1, PCC-1, and W-1 have been collected from 1647 journal articles and technical reports. These data are summarized in consensus (mean) values with uncertainties expressed as one standard deviation. Mean values are also calculated as a function of analytical procedure and all raw data are given in the tables. Recommended values are proposed based upon data criteria used by NIST (National Institute of Standards and Technology, formerly the National Bureau of Standrds or NBS).  相似文献   

10.
A radiochemical neutron activation technique for uranium determination in rock and mineral samples is presented. The method is based on an alkaline fusion, a selective oxidation of iodine by a sodium-nitrite solution, followed by an iodine distillation technique for the isolation of the 133I produced in fission. The outlined scheme is rapid, sensitive and reliable. Determination of uranium in U.S. Geological Survey standard rocks (G-1, W-1, G-2, BCR-1, AGV-1, GSP-1), C.R.P.G. Nancy geochemical standards (GA, GH, BR, Mica-Fe, Mica-Mg), C.A.A.S. reference syenite rocks (SY-1, SY-2, SY-3) and other analysed rock samples are reported. These results are compared with those obtained by other methods.  相似文献   

11.
Total carbon and inorganic carbon were determined by coulometric titration for 18 National Bureau of Standards (NBS) Standard Reference Material (SRM) and 4 Canadian Certified Reference Project Standards (CCRMP). A wide range of carbon contents was represented in the samples, which included biological, geological, and environmental materials. The analytical data produced helps fill gaps in the available literature for total and inorganic carbon values.  相似文献   

12.
Data are presented for twenty standard reference materials currently available from the USA's National Institute of Standards and Technology (NIST) that are of use in geochemical analyses. Some of these standards have not been previously presented in the geochemical literature and many elements'concentrations are reported here for the first time. Instrumental neutron activation analysis, X-ray fluorescence, colorimetry, and coulometry were employed to obtain results on ten major and thirty-eight trace element concentrations as well as H2O+ and H2O-. Error bars for the analyses as well as consensus values from the literature are presented and generally good agreement are obtained for the available values.  相似文献   

13.
Third in the series of collaborative studies launched by the International Working Group "Analytical Standards of Minerals, Ores and Rocks" (IWG), the study on Ailsa Craig Granite AC-E has attracted the participation of 128 laboratories from 29 countries. Tables of compiled data, 3212 results in all, are presented with working values, recommended or proposed, for seventy major, minor and trace elements. The success of this study which lasted for only one year from the distribution of sample to the release of the present report is to be attributed entirely to the record participation of the IWG-Member laboratories.  相似文献   

14.
The paper presents preliminary results of the use of a high resolution double-focussing, magnetic sector inductively coupled plasma-mass spectrometer (HR-ICP-MS) with ultraviolet laser ablation (LA) for the bulk analysis of geological materials fused with Li2B4O7. Detection limits are based on data from precision measurements of a fused SiO2 sample of high purity, and sensitivity data (cps/μg g-1) obtained on the Reference Material (RM) Syenite SY-2. For many trace elements, the detection limits are better than 0.05 μg g-1 using a sample to flux weight ratio of 1:7.
Calibration curves, which are based entirely on RMs, are established for Hf, Ta, Tb, Tm and Lu. They indicate that, even at this early stage in the development of the technique, data accurate to ˜ 25% can be collected. It is concluded that the method may prove to be a valuable supplement to XRF for low level element concentration measurements; it is also very practical, as the same sample discs can be used for both XRF and LA-ICP-MS analyses.  相似文献   

15.
Total sulfur is an analyte for which there are few determinations published, despite the fact that it is a very important element (e.g., a major element in most ores, an important gas constituent in global warming, an active participant in acid drainage). Most geological reference materials have very poor quality sulfur results, that is with relative standard deviations (RSD) in the range of 30–50%, even for concentrations over 100 μg g−1 S, which compromises their use as calibrators. In order to provide modern results with low RSD, sulfur was determined in twenty-nine geological reference materials with a state-of-the-art elemental S/C analyser using metal chips (certified reference materials with a traceability link) and analytical grade sulfur for high concentration samples. Analytical parameters (sample mass, crucible degassing, calibration strategy, etc.) were optimised by testing. Our results agreed with reference material values provided by issuing bodies. Results for CCRMP SY-2 (129 ± 13 μg g−1 S), which has been proposed as a sulfur reference material, were in agreement with the proposed modern value of 122 ± 3.7 μg g−1 S.  相似文献   

16.
Microanalytical trace element techniques (such as ion probe or laser ablation ICP-MS) are hampered by a lack of well characterized, homogeneous standards. Two silicate glass reference materials produced by National Institute of Standards and Technology (NIST), NIST SRM 610 and NIST SRM 612, have been shown to be homogeneous and are spiked with up to sixty one trace elements at nominal concentrations of 500 μg g-1 and 50 μg g-1 respectively. These samples (supplied as 3 mm wafers) are equivalent to NIST SRM 611 and NIST SRM 613 respectively (which are supplied as 1 mm wafers) and are becoming more widely used as potential microanalytical reference materials. NIST however, only certifies up to eight elements in these glasses. Here we have compiled concentration data from approximately sixty published works for both glasses, and have produced new analyses from our laboratories. Compilations are presented for the matrix composition of these glasses and for fifty eight trace elements. The trace element data includes all available new and published data, and summaries present the overall average and standard deviation, the range, median, geometric mean and a preferred average (which excludes all data outside ± one standard deviation of the overall average). For the elements which have been certified, there is a good agreement between the compiled averages and the NIST data. This compilation is designed to provide useful new working values for these reference materials.  相似文献   

17.
A revised list of reference samples of interest to geoscientists has been extended to include samples for the agronomist, the archaeologist and the environmentalist. In addition to the source from which standard samples may be obtained, references or pertinent notes for some samples are included.The number of rock reference samples is now almost adequate, and the variety of ore samples will soon be sufficient. There are very few samples for microprobe work. Oil shales will become more important because of the outlook for world petroleum resources. The dryland equivalent of a submarine basalt might be useful in studies of sea-floor spreading and of the geochemistry of basalts.The Na- and K-feldspars of BCS (British Chemical Standards—Bureau of Analysed Samples), NBS (National Bureau of Standards), and ANRT (Association Kationale de la Recherche Technique) could serve as trace-element standards if such data were available. Similarly, the present NBS flint and plastic clays, as well as their predecessors, might be useful for archaeological pottery studies. The International Decade for Ocean Exploration may stimulate the preparation of ocean-water standards for trace elements or pollutants and a standard for manganese nodules.  相似文献   

18.
Standards for the exchange of machine-readable data are discussed at five levels covering (1) physical characteristics of the medium used in the exchange, (2) overall structure of the data file, (3) format of individual records, (4) types of information contained in a record, and (5) authority files for information definition. The standards are used by the National Geothermal information Resource for compilations of geothermal energy data.This paper was presented at the International Geological Correlation Program (IGCP) Project 98 entitled Standards for Computer Applications in Resource Studies held at Loen, Norway, September 27–October 1, 1976.  相似文献   

19.
Two reference samples, Albite AL-I and Iron Formation sample IF-G were analysed for their chemical composition by the International Working Group "Analytical Standards of Minerals, Ores and Rocks" (GIT-IWG). AL-I was processed in 189 kg and IF-G and 760 kg. 103 GIT-IWG laboratories participated in this collaborative study along with 171 geoanalysts. This study lasted 15 months (September 1982 - December 1983) and is the second undertaken by the GIT-IWG. Over 2400 units of data were collated. As a result of this international study, the major and minor elements have been well characterized in both the samples; however, more data on trace elements will be very welcome for a better definition of trace elements, although working values have been proposed for about forty trace elements in each sample. The first and the second collaborative studies undertaken by GIT-IWG demonstrate well the immense analytical potential of the GIT-IWG.  相似文献   

20.
The Canadian Certified Reference Materials Project announces recommended values for radium-226 activity in four reference materials previously certified for uranium. Thirteen laboratories participated in the interlaboratory program for DL-la, DH-la, BL-4a and BL-5. Four measurement techniques were applied. Procedural and instrument calibrations were performed with certified radium solutions from the National Bureau of Standards, thereby establishing traceability of the recommended values for radium-226 in DL-la, DH-la, BL-4a and BL-5. These reference ores are also shown to be close to, if not in, radioactive equilibrium.  相似文献   