首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A field study of oxygen-enhanced biodegradation was carried out in a sandy iron-rich ground water system contaminated with gasoline hydrocarbons. Prior to the oxygen study, intrinsic microbial biodegradation in the contaminant plume had depleted dissolved oxygen and created anaerobic conditions. An oxygen diffusion system made of silicone polymer tubing was installed in an injection well within an oxygen delivery zone containing coarse highly permeable sand. During the study, this system delivered high dissolved oxygen (DO) levels (39 mg/L) to the ground water within a part of the plume. The ground water was sampled at a series of monitors in the test zone downgradient of the delivery well to determine the effect of oxygen on dissolved BTEX, ground water geochemistry, and microbially mediated biodegradation processes. The DO levels and Eh increased markedly at distances up to 2.3 m (7.5 feet) downgradient. Potential biofouling and iron precipitation effects did not clog the well screens or porous medium. The increased dissolved oxygen enhanced the population of aerobes while the activity of anaerobic sulfate-reducing bacteria and methanogens decreased. Based on concentration changes, the estimated total rate of BTEX biodegradation rose from 872 mg/day before enhancement to 2530 mg/day after 60 days of oxygen delivery. Increased oxygen flux to the test area could account for aerobic biodegradation of 1835 mg/day of the BTEX. The estimated rates of anaerobic biodegradation processes decreased based on the flux of sulfate, iron (II), and methane. Two contaminants in the plume, benzene and ethylbenzene, are not biodegraded as readily as toluene or xylenes under anaerobic conditions. Following oxygen enhancement, however, the benzene and ethylbenzene concentrations decreased about 98%, as did toluene and total xylenes.  相似文献   

2.
Evaluation of BTEX Remediation by Natural Attenuation at a Coastal Facility   总被引:1,自引:0,他引:1  
Natural attenuation has emerged as a potential alternative for remediating sites contaminated with fuel hydrocarbons. This paper examines the viability of using attenuation through natural processes to remediate ground water at an industrial facility. The research combined field assessments with data analysis and modeling to evaluate plume stability and predict remediation times. Field data on natural attenuation indicate that BTEX contamination at the site is being attenuated at rates that vary within the range of 0.0001 to 0.0073/day. Stability analyses confirm that the BTEX plume has reached steady state. An analysis on mass flux showed that between 1979 and 1996, 95,000 pounds of BTEX were lost via biodegradation, while 8000 pounds were lost through other mechanisms. A first-order biodegradation rate of 0.0002/day for BTEX was obtained from the change in the total mass of dissolved BTEX with time. Cleanup times in excess of 200 years for the site were estimated using analytical modeling of natural attenuation, which agreed well with the remediation times estimated using the attenuation rates calculated for the site.  相似文献   

3.
Like tree rings, high‐resolution soil sampling of low‐permeability (low‐k) zones can be used to evaluate the style of source history at contaminated sites (i.e., historical pattern of concentration and composition vs. time since releases occurred at the interface with the low‐k zone). This is valuable for the development of conceptual site model (CSM) and can serve as an important line of evidence supporting monitored natural attenuation (MNA) as a long‐term remedy. Source histories were successfully reconstructed at two sites at Naval Air Station Jacksonville using a simple one‐dimensional (1D) model. The plume arrival time and historical composition were reconstructed from the time initial releases that were suspected to occur decades earlier. At the first site (Building 106), the source reconstructions showed relatively constant source concentrations, but significant attenuation over time in the downgradient plume in the transmissive zone, suggesting MNA may not be an appropriate remedy if source control is a requirement, but attenuation processes are clearly helping to maintain plume stability and reduce risk. At the second site (Building 780), source concentrations in the transmissive zone showed an approximately a one order of magnitude over time, but apparently less attenuation in the downgradient plume. The source reconstruction method appeared to reflect site remediation efforts (excavation, soil vapor extraction) implemented in the 1990s. Finally, a detailed analysis using molecular biological tools, carbon isotopes, and by‐products suggests that most degradation activity is associated with high‐k zones but not with low‐k zones at these source areas. Overall, the source reconstruction methodology provided insight into historical concentration trends not obtainable otherwise given the limited long‐term monitoring data.  相似文献   

4.
Geochemical Indicators of Intrinsic Bioremediation   总被引:19,自引:0,他引:19  
A detailed field investigation has been completed at a gasoline-contaminated aquifer near Rocky Point, NC, to examine possible indicators of intrinsic bioremediation and identify factors that may significantly influence the rate and extent of bioremediation. The dissolved plume of benzene, toluene, ethylbenzene, and xylene (BTEX) in ground water is naturally degrading. Toluene and o-xylene are most rapidly degraded followed by m-, p-xylene, and benzene. Ethylbenzene appears to degrade very slowly under anaerobic conditions present in the center of the plume. The rate and extent of biodegradation appears to be strongly influenced by the type and quantity of electron acceptors present in the aquifer. At the upgradient edge of the plume, nitrate, ferric iron, and oxygen are used as terminal electron acceptors during hydrocarbon biodegradation. The equivalent of 40 to 50 mg/I of hydrocarbon is degraded based on the increase in dissolved CO2 relative to background ground water. Immediately downgradient of the source area, sulfate and iron are the dominant electron acceptors. Toluene and o-xylene are rapidly removed in this region. Once the available oxygen, nitrate, and sulfate are consumed, biodegradation is limited and appears to be controlled by mixing and aerobic biodegradation at the plume fringes.  相似文献   

5.
Methyl tert -butyl ether (MTBE) and benzene have been measured since 1993 in a shallow, sandy aquifer contaminated by a mid-1980s release of gasoline containing fuel oxygenates. In wells downgradient of the release area, MTBK was detected before benzene, reflecting a chromatographic-like separation of these compounds in the direction of ground water flow. Higher concentrations of MTBE and benzene were measured in the deeper sampling ports of multilevel sampling wells located near the release area, and also up to 10 feet (3 m) below the water table surface in nested wells located farther from the release area. This distribution of higher concentrations at depth is caused by recharge events that deflect originally horizontal ground water flowlines. In the laboratory, microcosms containing aquifer material incubated with uniformly labeled 14C-MTBE under aerobic and anaerobic. Fe(III)-reducing conditions indicated a low but measurable biodegradation potential (<3%14C-MTBW as 14CO2) after a seven-month incubation period, Tert -butyl alcohol (TBA), a proposed microbial-MTBE transformation intermediate, was detected in MTBE-contaminated wells, but TBA was also measured in unsaturated release area sediments. This suggests that TBA may have been present in the original fuel spilled and does not necessarily reflect microbial degradation of MTBE. Combined, these data suggest that milligram per liter to microgram per liter decreases in MTBE concentrations relative to benzene are caused by the natural attenuation processes of dilution and dispersion with less-contaminated ground water in the direction of flow rather than biodegradation at this point source gasoline release site.  相似文献   

6.
Ground water scientists have made significant advances in understanding the soil interactions, hydrogeology, fate and transport, and subsurface microbiology of aromatic hydrocarbons (BTEX) in aquifer systems. It is now generally recognized that a major factor responsible for the attenuation and mass reduction of BTEX in plumes is the widespread occurrence of hydrocarbon biodegradation by indigenous soil microorganisms in aquifer material. Most well-studied BTEX plumes that develop from the accidental release of gasoline fuels contain low levels of soluble hydrocarbons (< 1 to 5000 ppb) and have been shown to be spatially confined because of natural biotransformation mechanisms. These in situ processes are controlled by source and aquifer characteristics, permeability, sorption, and geochemical properties of the aquifer. Many laboratory subsoil-ground water microcosms and field studies (10 to 20 C) have demonstrated the rapid biodecay (1 to SO percent/day for microcosms and 0.5 to 1.5 percent/day for plumes) of these aromatic compounds under primarily aerobic conditions (i.e., those with sufficient dissolved oxygen). The ability to implement ground water bioremediation will depend upon our understanding of source control and aquifer recharge effects on the spatial distribution of plumes. In addition, estimating the biodegradation of sorbed BTEX, determining limits and potential for in situ biostimulation of soluble plumes, and establishing data requirements for predictive modeling of natural attenuation will be useful for this remediation technology. The use of these tools to manage ground water quality appears to represent the most practical alternative, particularly for low-risk ground water supplies.  相似文献   

7.
In 1988 and 1989, a natural gradient tracer test was performed in the shallow, aerobic and aquifer at Canadian Forces Base (CFB) Borden. A mixture of ground water containing dissolved oxygenated gasoline was injected below the water table along with chloride (Cl-) as a conservative tracer. The migration of BTEX, MTBE, and Cl was monitored in detail for 16 moths. The mass of BTEX compounds in the plume diminished significantly with time due to intrinsic aerobic biodegradation, while MTBE showed only a small decrease in mass over the 16-month period. In 1995/96, a comprehensive ground water sampling program was undertaken to define the mass of MTBE still present in the aquifer. Since the plume had migrated into an unmonitored section of the Borden Aquifer, numerical modeling and geostatistical methods were applied to define an optimal sampling grid and to improve the level of confidence in the results. A drive point profiling system was used to obtain ground water samples. Numerical modeling with no consideration of degradation pedicted maximum concentrations in excess of 3000 μg/L; field sampling found maximum concentrations of less than 200 μg/L. A mass balance for the remaining MTBE mass in the aquifer eight years after injection showed that only 3% of the original mass remained. Sorption, volatilization, a biotic degradation, and plant uptake are not considered significant attenuation processes for the field conditions. Therefore, we suggest that biodegradation may have played a major role in the attenuation of MTBE within the Borden Aquifer.  相似文献   

8.
A numerical study was conducted to investigate the influence of tides on the fate of terrestrially derived BTEX discharging through an unconfined aquifer to coastal waters. Previous studies have revealed that tide-induced seawater circulations create an active salt–freshwater mixing zone in the near-shore aquifer and alter the specific subsurface pathway for contaminants discharging to the coastal environment. Here the coupled density-dependent flow and multi-species reactive transport code PHWAT was used to examine the impact of these tidal effects on the aerobic biodegradation of BTEX released in a coastal aquifer and its subsequent loading to coastal waters. Simulations indicated that tides significantly enhance BTEX attenuation in the near-shore aquifer. They also reduce the rate of chemical transfer from the aquifer to the ocean and exit concentrations at the beach face. For the base case consisting of toluene transport and biodegradation, 79% of toluene initially released in the aquifer was attenuated prior to discharge with tides present, compared to only 1.8% for the non-tidal case. The magnitude of tidal forcing relative to the fresh groundwater flow rate was shown to influence significantly the extent of biodegradation as it controls the intensity of salt–freshwater mixing, period of exposure of the contaminant to the mixing zone and rate of oxygen delivery to the aquifer. The oxygen available for biodegradation also depends on the rate at which oxygen is consumed by natural processes such as organic matter decomposition. While simulations conducted with heterogeneous conductivity fields highlighted the uncertainties associated with predicting contaminant loadings, the study revealed overall that BTEX may undergo significant attenuation in tidally influenced aquifers prior to discharge.  相似文献   

9.
Sulfate reducing conditions are widely observed in groundwater plumes associated with petroleum hydrocarbon releases. This leads to sulfate depletion in groundwater which can limit biodegradation of hydrocarbons (usually benzene, toluene, ethylbenzene, xylenes [BTEX] compounds) and can therefore result in extended timeframes to achieve groundwater cleanup objectives by monitored natural attenuation. Under these conditions, sulfate addition to the subsurface can potentially enhance BTEX biodegradation and facilitate enhanced natural attenuation. However, a delivery approach that enables effective contact with the hydrocarbons and is able to sustain elevated and uniform sulfate concentrations in groundwater remains a key challenge. In this case study, sulfate addition to a groundwater plume containing predominantly benzene by land application of agricultural gypsum and Epsom salt is described. Over 4 years of groundwater monitoring data from key wells subjected to pilot‐scale and site‐wide land application events are presented. These are compared to data from pilot testing employing liquid Epsom salt injections as an alternate sulfate delivery approach. Sulfate land application, sulfate retention within the vadose zone, and periodic infiltration following ongoing precipitation events resulted in elevated sulfate concentrations (>150 mg/L) in groundwater that were sustained over 12 months between application events and stimulated benzene biodegradation as indicated by declines in dissolved benzene concentration, and compound‐specific isotope analysis data for carbon in benzene. Long‐term groundwater benzene concentration reductions were achieved in spite of periodic rebounds resulting from water table fluctuations across the smear zone. Land application of gypsum is a potentially cost‐effective sulfate delivery approach at sites with open, unpaved surfaces, relatively permeable geology, and shallow hydrocarbon impacts. However, more research is needed to understand the fate and persistence of sulfate and to improve the likelihood of success and effectiveness of this delivery approach.  相似文献   

10.
This research continues a 7-year study of oxygen-containing organic compounds present in groundwater at gasoline and diesel fuel release sites that are quantified as diesel-range “total petroleum hydrocarbons” when measured by methods utilizing solvent extraction and gas chromatography. Two-dimensional gas chromatography with time-of-flight mass spectrometry was used to tentatively identify 1162 compounds (TICs) in 113 groundwater samples from 22 sites. Samples were collected from wells either upgradient of the release, within the source zone, or downgradient of the source but still within the plume of dissolved organics associated with release. The names and formulas of all TICs found in samples from each well type are presented and the results from upgradient and downgradient locations are compared in detail. About 60% of the most frequently detected TICs in downgradient wells were also detected in upgradient wells. A majority of these were saturated straight chain alkyl acids, commonly called fatty acids, or fatty acid esters. Of TICs frequently detected in downgradient wells but not upgradient wells, over half were branched alkyl alcohols. Hierarchical cluster analysis results suggest about 80% of the chemical composition of downgradient samples is more similar to upgradient samples than to source area samples. This similarity is due to the presence of the same types of fatty acids and esters. Principal component analysis indicates a continuum of biodegradation between the source area and downgradient samples with the latter becoming more consistent with upgradient samples. Results suggest some TICs may not be petroleum degradation intermediates but compounds synthesized by microorganisms through secondary production and carbon cycling.  相似文献   

11.
Chlorinated solvents are one of the most commonly detected groundwater contaminants in industrial areas. Identification of polluters and allocation of contaminant sources are important concerns in the evaluation of complex subsurface contamination with multiple sources. In recent years, compound‐specific isotope analyses (CSIA) have been employed to discriminate among different contaminant sources and to better understand the fate of contaminants in field‐site studies. In this study, the usefulness of dual isotopes (carbon and chlorine) was shown in assessments of groundwater contamination at an industrial complex in Wonju, Korea, where groundwater contamination with chlorinated solvents such as trichloroethene (TCE) and carbon tetrachloride (CT) was observed. In November 2009, the detected TCE concentrations at the study site ranged between nondetected and 10,066 µg/L, and the CT concentrations ranged between nondetected and 985 µg/L. In the upgradient area, TCE and CT metabolites were detected, whereas only TCE metabolites were detected in the downgradient area. The study revealed the presence of separate small but concentrated TCE pockets in the downgradient area, suggesting the possibility of multiple contaminant sources that created multiple comingling plumes. Furthermore, the variation of the isotopic (δ13C and δ37Cl) TCE values between the upgradient and downgradient areas lends support to the idea of multiple contamination sources even in the presence of detectable biodegradation. This case study found it useful to apply a spatial distribution of contaminants coupled with their dual isotopic values for evaluation of the contaminated sites and identification of the presence of multiple sources in the study area.  相似文献   

12.
Many studies indicate that small‐scale heterogeneity and/or mobile–immobile mass exchange produce transient non‐Fickian plume behavior that is not well captured by the use of the standard, deterministic advection‐dispersion equation (ADE). An extended ADE modeling framework is presented here that is based on continuous time random walk theory. It can be used to characterize non‐Fickian transport coupled with simultaneous sequential first‐order reactions (e.g., biodegradation or radioactive decay) for multiple degrading contaminants such as chlorinated solvents, royal demolition explosive, pesticides, and radionuclides. To demonstrate this modeling framework, new transient analytical solutions are derived and are inverted in Laplace space. Closed‐form, steady‐state, multi‐species analytical solutions are also derived for non‐Fickian transport in highly heterogeneous aquifers with linear sorption–desorption and matrix diffusion for use in spreadsheets. The solutions are general enough to allow different degradation rates for the mobile and immobile zones. The transient solutions for multi‐species transport are applied to examine the effects of source remediation on the natural attenuation of downgradient plumes of both parent and degradation products in highly heterogeneous aquifers. Results for representative settings show that the use of the standard, deterministic ADE can over‐estimate cleanup rates and under‐predict the cleanup timeframe in comparison to the extended ADE analytical model. The modeling framework and calculations introduced here are also applied for a 30 year groundwater cleanup program at a site in Palm Bay, Florida. The simulated plume concentrations using the extended ADE exhibited agreement with observed long concentration tails of trichloroethene, cis 1,2 DCE, and VC that remained above cleanup goals.  相似文献   

13.
Aerobic biodegradation can contribute significantly to the attenuation of petroleum hydrocarbons vapors in the unsaturated zone; however, most regulatory guidance for assessing potential human health risks via vapor intrusion to indoor air either neglect biodegradation in developing generic screening levels or allow for only one order of magnitude additional attenuation for aerobically degradable compounds, which may be overly conservative in some cases. This paper describes results from three-dimensional numerical model simulations of vapor intrusion for petroleum hydrocarbons to assess the influence of aerobic biodegradation on the attenuation factor for a variety of source concentrations and depths for residential buildings with basements and slab-on-grade construction. The simulations conducted in this study provide a framework for understanding the degree to which bioattenuation will occur under a variety of scenarios and provide insight into site conditions that will result in significant biodegradation. This improved understanding may be used to improve the conceptual model of contaminant transport, guide field data collection and interpretation, and estimate semi-site-specific attenuation factors for combinations of source concentrations, source depth, oxygen distribution, and building characteristics where site conditions reasonably match the scenarios simulated herein.  相似文献   

14.
A field lest to evaluate the applicability of an oxygon-releasing compound (ORC) to the rernediation of ground water contaminated with benzone and toluene was conducted in the Borden Aquifer in Ontario. Canada. Benzene and toluene were injected as organic substrates to represent BTEX compounds, bromide was used as a tracer, and nitrate was added to avoid nitrate-limited conditions.
The fate of the solutes was monitored along four lines of monitoring points and wells. Two lines studied the behavior of the solutes upgradient and downgradient of two large-diameter well screens filled with briquets containing ORC and briquets without ORC. One line was used to study the solute behavior upgradient and downgradient of columns of ORC powder placed directly in the saturated zone. The remaining line was a control.
The results indicate that ORC in both briquet and powder form can release significant amounts of oxygen to conlaminated ground water passing by it. In the formulation used in this work, oxygen release persisted for at least 10 weeks. Furthemiore, the study indicates that the enhancement of the available dissolved oxygen content of at least 4 mg/L each of the ground water by ORC can support biodegradation of benzene and toluene dissolved in ground water. Such concentrations are typical of those encountered at sites contaminated with petroleum hydrocarbons; therefore, these results suggest that there is promise for ORC to enhance in situ biodegradation of BTKX contaminants at such sites using passive (nonpumping) systems to contact the contaminated ground water with the oxygen source.  相似文献   

15.
Dense nonaqueous phase liquid (DNAPL) source areas containing chlorinated volatile organic compounds (cVOCs) such as trichloroethene (TCE) and perchloroethene (PCE) often give rise to significant dissolved plumes in groundwater, leading to the closure of downgradient water supply wells and creating vapor intrusion issues in buildings located above the plume. Hydraulic containment via pump‐and‐treat has often been implemented to limit migration but must continue indefinitely. Removal of the DNAPL source area by means such as in situ thermal remediation (ISTR) offers the potential to diminish or end the need for hydraulic containment if the associated dissolved plume attenuates sufficiently following source removal. A question often raised is whether this occurs or whether the back diffusion of contaminants from secondary sources such as low‐permeability lenses in the dissolved plume precludes it. The authors conducted DNAPL source removal using ISTR at dozens of sites. This paper presents a compilation of cases—10 separate DNAPL source areas at five project sites—where data indicate that the implementation of a thorough ISTR in a DNAPL source area can result in the attenuation of the associated dissolved plume, such that in several cases, long‐standing pump‐and‐treat systems could be turned off. Our findings contrast with recent assertions that aggressive source remediation may not be justifiable because dissolved plume concentrations will not decline sufficiently. We show that the application of ISTR can result in the thorough removal of the DNAPL source, effective diminution of dissolved plume groundwater concentrations, and achievement of drinking water standards.  相似文献   

16.
Evaluation of volatilization as a natural attenuation pathway for MTBE   总被引:2,自引:0,他引:2  
Lahvis MA  Baehr AL  Baker RJ 《Ground water》2004,42(2):258-267
Volatilization and diffusion through the unsaturated zone can be an important pathway for natural attenuation remediation of methyl tert-butyl ether (MTBE) at gasoline spill sites. The significance of this pathway depends primarily on the distribution of immiscible product within the unsaturated zone and the relative magnitude of aqueous-phase advection (ground water recharge) to gaseous-phase diffusion. At a gasoline spill site in Laurel Bay, South Carolina, rates of MTBE volatilization from ground water downgradient from the source are estimated by analyzing the distribution of MTBE in the unsaturated zone above a solute plume. Volatilization rates of MTBE from ground water determined by transport modeling ranged from 0.0020 to 0.0042 g m(-2)/year, depending on the assumed rate of ground water recharge. Although diffusive conditions at the Laurel Bay site are favorable for volatilization, mass loss of MTBE is insignificant over the length (230 m) of the solute plume. Based on this analysis, significant volatilization of MTBE from ground water downgradient from source areas at other sites is not likely. In contrast, model results indicate that volatilization coupled with diffusion to the atmosphere could be a significant mass loss pathway for MTBE in source areas where residual product resides above the capillary zone. Although not documented, mass loss of MTBE at the Laurel Bay site due to volatilization and diffusion to the atmosphere are predicted to be two to three times greater than mass loading of MTBE to ground water due to dissolution and recharge. This result would imply that volatilization in the source zone may be the critical natural attenuation pathway for MTBE at gasoline spill sites, especially when considering capillary zone limitations on volatilization of MTBE from ground water and the relative recalcitrance of MTBE to biodegradation.  相似文献   

17.
A detailed seasonal study of soil vapor intrusion at a cold climate site with average yearly temperature of 1.9 °C was conducted at a house with a crawlspace that overlay a shallow dissolved‐phase petroleum hydrocarbon (gasoline) plume in North Battleford, Saskatchewan, Canada. This research was conducted primarily to assess if winter conditions, including snow/frost cover, and cold soil temperatures, influence aerobic biodegradation of petroleum vapors in soil and the potential for vapor intrusion. Continuous time‐series data for oxygen, pressure differentials, soil temperature, soil moisture, and weather conditions were collected from a high‐resolution monitoring network. Seasonal monitoring of groundwater, soil vapor, crawlspace air, and indoor air was also undertaken. Petroleum hydrocarbon vapor attenuation and biodegradation rates were not significantly reduced during low temperature winter months and there was no evidence for a significant capping effect of snow or frost cover that would limit oxygen ingress from the atmosphere. In the residual light nonaqueous phase liquid (LNAPL) source area adjacent to the house, evidence for biodegradation included rapid attenuation of hydrocarbon vapor concentrations over a vertical interval of approximately 0.9 m, and a corresponding decrease in oxygen to less than 1.5% v/v. In comparison, hydrocarbon vapor concentrations above the dissolved plume and below the house were much lower and decreased sharply within a few tens of centimeters above the groundwater source. Corresponding oxygen concentrations in soil gas were at least 10% v/v. A reactive transport model (MIN3P‐DUSTY) was initially calibrated to data from vertical profiles at the site to obtain biodegradation rates, and then used to simulate the observed soil vapor distribution. The calibrated model indicated that soil vapor transport was dominated by diffusion and aerobic biodegradation, and that crawlspace pressures and soil gas advection had little influence on soil vapor concentrations.  相似文献   

18.
This study evaluates the efficiency of a full‐scale, 81 m‐wide permeable reactive barrier (PRB) configured by injection of dairy whey in the downgradient region of a contaminant source zone to enhance the in situ biodegradation of high concentrations (102 to 103μg/L) of chlorinated ethenes (CEs). Ten biannual whey injections were completed in a 3.5‐year pilot phase and 1.5‐year operational phase. Improved and sustained dechlorination was observed at extraction/injection and downgradient wells in the fully‐operational phase, when dried whey masses were increased from 13.6 kg to 230–360 kg, whey slurry volumes were increased from 2300 L to 307,000–480,000 L, and extraction/injection well loops were employed for the application of whey. At extraction/injection wells, CEs decreased to low (≤10 μg/L) or undetectable levels. At downgradient wells, average trichloroethene concentrations decreased, by as much as 100% (from ≤384.2 during the pilot phase to ≤102.6 μg/L during the operational phase), while average cis‐dichloroethene concentrations decreased by as much as 57.5% (from ≤6466.1 to ≤4912.2 μg/L). Downgradient vinyl chloride averages either increased by as much as 63.8% (from ≤859.6 to ≤1407.9 μg/L) or decreased by 64.0% (from 1375.4 to 880 μg/L). Downgradient ethene + ethane averages increased by as much as 73.2% (from ≤1145.3 to ≤1347.1 μg/L). On the basis of the 2008 average market price, the estimated material cost of whey is $1.96/kg organic carbon or, for the configuration of an 81 m PRB by biannual application of 300 kg whey, $325/year. Carbon substrate cost comparisons and implications for efficient in situ treatment design are discussed.  相似文献   

19.
Monitored natural attenuation is widely applied as a remediation strategy at hydrocarbon spill sites. Natural attenuation relies on biodegradation of hydrocarbons coupled with reduction of electron acceptors, including solid phase ferric iron (Fe(III)). Because arsenic (As) adsorbs to Fe‐hydroxides, a potential secondary effect of natural attenuation of hydrocarbons coupled with Fe(III) reduction is a release of naturally occurring As to groundwater. At a crude‐oil‐contaminated aquifer near Bemidji, Minnesota, anaerobic biodegradation of hydrocarbons coupled to Fe(III) reduction has been well documented. We collected groundwater samples at the site annually from 2009 to 2013 to examine if As is released to groundwater and, if so, to document relationships between As and Fe inside and outside of the dissolved hydrocarbon plume. Arsenic concentrations in groundwater in the plume reached 230 µg/L, whereas groundwater outside the plume contained less than 5 µg/L As. Combined with previous data from the Bemidji site, our results suggest that (1) naturally occurring As is associated with Fe‐hydroxides present in the glacially derived aquifer sediments; (2) introduction of hydrocarbons results in reduction of Fe‐hydroxides, releasing As and Fe to groundwater; (3) at the leading edge of the plume, As and Fe are removed from groundwater and retained on sediments; and (4) downgradient from the plume, patterns of As and Fe in groundwater are similar to background. We develop a conceptual model of secondary As release due to natural attenuation of hydrocarbons that can be applied to other sites where an influx of biodegradable organic carbon promotes Fe(III) reduction.  相似文献   

20.
Chlororespiration is common in shallow aquifer systems under conditions nominally identified as anoxic. Consequently, chlororespiration is a key component of remediation at many chloroethene‐contaminated sites. In some instances, limited accumulation of reductive dechlorination daughter products is interpreted as evidence that natural attenuation is not adequate for site remediation. This conclusion is justified when evidence for parent compound (tetrachloroethene, PCE, or trichloroethene, TCE) degradation is lacking. For many chloroethene‐contaminated shallow aquifer systems, however, nonconservative losses of the parent compounds are clear but the mass balance between parent compound attenuation and accumulation of reductive dechlorination daughter products is incomplete. Incomplete mass balance indicates a failure to account for important contaminant attenuation mechanisms and is consistent with contaminant degradation to nondiagnostic mineralization products like CO2. While anoxic mineralization of chloroethene compounds has been proposed previously, recent results suggest that oxygen‐based mineralization of chloroethenes also can be significant at dissolved oxygen concentrations below the currently accepted field standard for nominally anoxic conditions. Thus, reassessment of the role and potential importance of low concentrations of oxygen in chloroethene biodegradation are needed, because mischaracterization of operant biodegradation processes can lead to expensive and ineffective remedial actions. A modified interpretive framework is provided for assessing the potential for chloroethene biodegradation under different redox conditions and the probable role of oxygen in chloroethene biodegradation.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号