This work presents a novel procedure for identifying the dynamic characteristics of a building and diagnosing whether the building has been damaged by earthquakes, using a back‐propagation neural network approach. The dynamic characteristics are directly evaluated from the weighting matrices of the neural network trained by observed acceleration responses and input base excitations. Whether the building is damaged under a large earthquake is assessed by comparing the modal parameters and responses for this large earthquake with those for a small earthquake that has not caused this building any damage. The feasibility of the approach is demonstrated through processing the dynamic responses of a five‐storey steel frame, subjected to different strengths of the Kobe earthquake, in shaking table tests. Copyright © 2002 John Wiley & Sons, Ltd.  相似文献   

2.
The paper deals with gray box identification of flexible structures and active vibration suppression from a robust control perspective. First, the linearized mathematical model of an N‐storey flexible structure is presented. Next, the generalized mathematical model is particularized for the investigated three‐storey flexible structure. The considered flexible structure is identified based on black box and gray box identification methods and the model's parametric uncertainties are deduced. Furthermore, control constraints are presented for the design problem, in case of velocity as well as acceleration feedback, from a robust control perspective. Finally, the effectiveness of the control system is tested through experiments, when the input disturbance is assumed to be a sinusoidal one as well as a historical earthquake record (1940 El Centro record). Copyright © 2001 John Wiley & Sons, Ltd.  相似文献   

3.
A unified mathematical framework, sustained by experimental results, is presented for robust controller design taking into account the constraint on the control signal. The design procedure is exemplified for an active vibration suppression control problem with applications to flexible structures. The considered experimental set‐up is a three‐storey flexible structure with an active mass driver placed on the last storey. First, the considered flexible structure is identified and the model's parametric uncertainties are deduced. Next, control constraints are presented for the robust control design problem, taking into account the restriction imposed on the control signal. Finally, the effectiveness of the control system is tested through experiments, when the input disturbance is assumed to be a sinusoidal one as well as a historical earthquake record (1940 El Centro record). Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

4.
Ambient vibration tests were conducted on a base-isolated apartment building in Takamatsu, Japan, to determine the mode shapes and the associated natural frequencies and damping ratios at very low levels of excitation. The latest developments in signal analysis for modal decomposition are used to analyze the ambient response data. A finite element model of the building and isolators was calibrated and refined using the experimental results from the ambient vibration tests. This model was then used to simulate the recorded response of the building under excitation from a small earthquake. The finite element model, calibrated by ambient vibration data and the low level of earthquake shaking, provides the starting point for modelling the non-linear response of the building when subjected to strong shaking.  相似文献   

5.
This paper presents a statistical performance analysis of a semi‐active structural control system for suppressing the vibration response of building structures during strong seismic events. The proposed semi‐active mass damper device consists of a high‐frequency mass damper with large stiffness, and an actively controlled interaction element that connects the mass damper to the structure. Through actively modulating the operating states of the interaction elements according to pre‐specified control logic, vibrational energy in the structure is dissipated in the mass damper device and the vibration of the structure is thus suppressed. The control logic, categorized under active interaction control, is defined directly in physical space by minimizing the inter‐storey drift of the structure to the maximum extent. This semi‐active structural control approach has been shown to be effective in reducing the vibration response of building structures due to specific earthquake ground motions. To further evaluate the control performance, a Monte Carlo simulation of the seismic response of a three‐storey steel‐framed building model equipped with the proposed semi‐active mass damper device is performed based on a large ensemble of artificially generated earthquake ground motions. A procedure for generating code‐compatible artificial earthquake accelerograms is also briefly described. The results obtained clearly demonstrate the effectiveness of the proposed semi‐active mass damper device in controlling vibrations of building structures during large earthquakes. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

6.
This paper presents the application of system identification (SI) to long‐span cable‐supported bridges using seismic records. The SI method is based on the System Realization using Information Matrix (SRIM) that utilizes correlations between base motions and bridge accelerations to identify coefficient matrices of a state‐space model. Numerical simulations using a benchmark cable‐stayed bridge demonstrate the advantages of this method in dealing with multiple‐input multiple‐output (MIMO) data from relatively short seismic records. Important issues related to the effects of sensor arrangement, measurement noise, input inclusion, and the types of input with respect to identification results are also investigated. The method is applied to identify modal parameters of the Yokohama Bay Bridge, Rainbow Bridge, and Tsurumi Fairway Bridge using the records from the 2004 Chuetsu‐Niigata earthquake. Comparison of modal parameters with the results of ambient vibration tests, forced vibration tests, and analytical models are presented together with discussions regarding the effects of earthquake excitation amplitude on global and local structural modes. Copyright © 2007 John Wiley & Sons, Ltd.  相似文献   

7.
In countries with a moderate seismic hazard, the classical methods developed for strong motion prone countries to estimate the seismic behaviour and subsequent vulnerability of existing buildings are often inadequate and not financially realistic. The main goals of this paper are to show how the modal analysis can contribute to the understanding of the seismic building response and the good relevancy of a modal model based on ambient vibrations for estimating the structural deformation under weak earthquakes. We describe the application of an enhanced modal analysis technique (frequency domain decomposition) to process ambient vibration recordings taken at the Grenoble City Hall building (France). The frequencies of ambient vibrations are compared with those of weak earthquakes recorded by the French permanent accelerometric network (RAP) that was installed to monitor the building. The frequency variations of the building under weak earthquakes are shown to be less (∼2%) and therefore ambient vibration frequencies are relevant over the elastic domain of the building. The modal parameters extracted from ambient vibrations are then used to determine the 1D lumped‐mass model in order to reproduce the inter‐storey drift under weak earthquakes and to fix a 3D numerical model that could be used for strong earthquakes. The correlation coefficients between data and synthetic motion are close to 80 and 90% in horizontal directions, for the 1D and 3D modelling, respectively. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

8.
Damage assessment of a structure involves acquiring and identifying dynamic characteristics of the structure and using these characteristics to evaluate behavior and performance. In this study, an unsymmetrical three‐story steel structure (fabricated with one weak column in the first floor) was tested on shaking table and subjected to a series of earthquake excitations with increasing level of excitation back to back. Besides, white noise excitation was also applied in between the earthquake excitation to serve as the reference state. Both the traditional sensing system (accelerometer and linear variable differential transformer) and the local optical tracker system were implemented in the structure to collect the vibration‐based responses. For operational modal analysis, structural response from white noise excitation will be used in this study. First, the traditional system identification using global response data is used (multivariate autoregressive (AR)‐model) to extract system natural frequencies and mode shapes from all different set of white noise responses after earthquake excitation. The migration of AR‐coefficient ellipse error from each sensor response was used to identify the damage location. Second, blind source separation technique was used to identify the modal contribution of the structure from each test, which provide information to detect the damage severity. Finally, from the local optical tracker array data, the principal component analysis was applied to quantify the earthquake‐induce local stress of the structural member. Combine the result from damage detection using global measurement and the identified local element stress, one can locate and quantify the damage. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

9.
This paper proposes the use of a novel type of passive vibration control system to reduce vibrations in civil engineering structures subject to base excitation. The new system is based on the inerter, a device that was initially developed for high‐performance suspensions in Formula 1 racing cars. The principal advantage of the inerter is that a high level of vibration isolation can be achieved with low amounts of added mass. This feature makes it an attractive potential alternative to traditional tuned mass dampers (TMDs). In this paper, the inerter system is modelled inside a multi‐storey building and is located on braces between adjacent storeys. Numerical results show that an excellent level of vibration reduction is achieved, potentially offering improvement over TMDs. The inerter‐based system is compared to a TMD system by using a range of base excitation inputs, including an earthquake signal, to demonstrate how the performance could potentially be improved by using an inerter instead of a TMD. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

10.
Output‐only system identification is developed here towards assessing current modal dynamic properties of buildings under seismic excitation. Earthquake‐induced structural response signals are adopted as input channels for two different Operational Modal Analysis (OMA) techniques, namely, a refined Frequency Domain Decomposition (rFDD) algorithm and an improved Data‐Driven Stochastic Subspace Identification (SSI‐DATA) procedure. Despite that short‐duration, non‐stationary, earthquake‐induced structural response signals shall not fulfil traditional OMA assumptions, these implementations are specifically formulated to operate with seismic responses and simultaneous heavy damping (in terms of identification challenge), for a consistent estimation of natural frequencies, mode shapes, and modal damping ratios. A linear ten‐storey frame structure under a set of ten selected earthquake base‐excitation instances is numerically simulated, by comparing the results from the two identification methods. According to this study, best up‐to‐date, reinterpreted OMA techniques may effectively be used to characterize the current dynamic behaviour of buildings, thus allowing for potential Structural Health Monitoring approaches in the Earthquake Engineering range.  相似文献   

11.
钢结构房屋动力特性脉动法测试研究   总被引:3,自引:0,他引:3  
对上海地区的10幢钢结构建筑进行脉动法测试并采集数据,得到广义钢结构房屋的动力特性。选取其中1栋典型建筑通过多次测试和数值模拟分别验证测试的稳定性和准确性。通过分析处理测试数据建立钢结构建筑一阶周期与结构层数或高度的线性关系式,并归纳总结了等效阻尼比的测试结果,为验证结构动力特性理论计算结果、钢结构建筑减震隔震设计以及鉴定、加固改造、损伤识别提供依据。  相似文献   

12.
The aim of this paper is to adjust behaviour models for each class of structure for vulnerability assessment by using ambient vibration. A simple model based on frequencies, mode shapes and damping, taken from ambient vibrations, allows computation of the response of the structures and comparison of inter‐storey drifts with the limits found in the literature for the slight damage grade, considered here as the limit of elastic behaviour. Two complete methodologies for building fragility curves are proposed: (1) using a multi‐degree of freedom system including higher modes and full seismic ground‐motion and (2) using a single‐degree of freedom model considering the fundamental mode f0 of the structure and ground‐motion displacement response spectra SD(f0). These two methods were applied to the city of Grenoble, where 60 buildings were studied. Fragility curves for slight damage were derived for the various masonry and reinforced concrete classes of buildings. A site‐specific earthquake scenario, taking into account local site conditions, was considered, corresponding to an ML = 5.5 earthquake at a distance of 15 km. The results show the benefits of using experimental models to reduce variability of the slight damage fragility curve. Moreover, by introducing the experimental modal model of the buildings, it is possible to improve seismic risk assessment at an overall scale (the city) or a local scale (the building) for the first damage grade (slight damage). This level of damage, of great interest for moderate seismic‐prone regions, may contribute to the seismic loss assessment. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

13.
The insertion of steel braces equipped with viscoelastic dampers (VEDs) (‘dissipative braces’) is a very effective technique to improve the seismic or wind behaviour of framed buildings. The main purpose of this work is to compare the earthquake and wind dynamic response of steel‐framed buildings with VEDs and achieve optimal properties of dampers and supporting braces. To this end, a numerical investigation is carried out with reference to the steel K‐braced framed structure of a 15‐storey office building, which is designed according to the provisions of Eurocodes 1 and 3, and to four structures derived from the first one by the insertion of additional diagonal braces and/or VEDs. With regard to the VEDs, the following cases are examined: absence of dampers; insertion of dampers supported by the existing K‐braces in each of the structures with or without additional diagonal braces; insertion of dampers supported by additional diagonal braces. Dynamic analyses are carried out in the time domain using a step‐by‐step initial stress‐like iterative procedure. For this purpose, the frame members and the VEDs are idealized, respectively, by a bilinear model, which allows the simulation of the nonlinear behaviour under seismic loads, and a six‐element generalized model, which can be considered as an in‐parallel‐combination of two Maxwell models and one Kelvin model. Artificially generated accelerograms, whose response spectra match those adopted by Eurocode 8 for a medium subsoil class and for different levels of peak ground acceleration, are considered to simulate seismic loads. Along‐wind loads are considered assuming, at each storey, time histories of the wind velocity for a return period Tr=5 years, according to an equivalent spectrum technique. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

14.
Results of two detailed ambient vibration surveys of a 7-story reinforced concrete building in Van Nuys, California, are presented. Both surveys were conducted after the building was severely damaged by the 17 January 1994, Northridge earthquake (ML=5.3, epicenter 1.5 km west from the building site) and its early aftershocks. The first survey was conducted on 4 and 5 February 1994, and the second one on 19 and 20 April 1994, about one month after the 20 March aftershock (ML=5.3, epicenter 1.2 km north–west from the building site). The apparent frequencies and two- and three-dimensional mode shapes for longitudinal, transverse and vertical vibrations were calculated. The attempts to detect the highly localized damage by simple spectral analyses of the ambient noise data were not successful. It is suggested that very high spatial resolution of recording points is required to identify localized column and beam damage, due to the complex building behavior, with many interacting structural components. The loss of the axial capacity of the damaged columns could be seen in the vertical response of the columns, but similar moderate or weak damage typically would not be noticed in ambient vibration surveys. Previous analysis of the recorded response of this building to 12 earthquakes suggests that, during large response of the foundation and piles, the soil is pushed sideways and gaps form between the foundation and the soil. These gaps appear to be closing during “dynamic compaction” when the building site is shaken by many small aftershocks. The apparent frequencies of the soil–foundation–structure system appear to be influenced significantly by variations in the effective soil–foundation stiffness. These variations can be monitored by a sequence of specialized ambient vibration tests.  相似文献   

15.
Accurate prediction of the dynamic responses of a high-rise building subjected to dynamic loads such as earthquake and wind excitations requires the information of its structural dynamic properties such as modal parameters including natural frequencies and damping ratios. This paper presents the identification results of the modal parameters based on field vibration tests on a 600-m high skyscraper. A set of tests, including ambient vibration test (AVT) and free vibration test (FVT), were conducted on the skyscraper to identify its modal parameters. Firstly, this paper presents and discusses the modal parameters of the skyscraper assessed by several identification methods applied to the AVT measurements. These methods include the wavelet transform (WT) method, the stochastic subspace identification (SSI) method, and the random decrement technique (RDT). Secondly, an active mass damper (AMD) system with total mass 1000 tons equipped into the skyscraper was used to excite the building for estimation of the modal parameters by FVT. Thirdly, this paper presents observations on the structural dynamic behavior of the skyscraper with the operation of the AMD system during a typhoon event. The field measurement results show that the AMD system functioned efficiently for suppression of the wind-induced vibrations of the skyscraper during the typhoon. This paper aims to further understand the structural dynamic properties of super-tall buildings and provide useful information for structural design and vibration control of future skyscrapers.  相似文献   

16.
The traffic‐induced variability in the dynamic properties of a cable‐stayed bridge is investigated using ambient vibration measurements. Under a relatively steady wind and temperature environment, the ambient vibration test was conducted on the bridge with normal traffic conditions and totally 24 h acceleration response time histories were recorded. These data are divided into 12 sections with each data section containing 2 h measurements. Thereby the modal variability due to changing traffic loading is investigated through post‐processing of the data in each section in both amplitude and frequency domains. The result indicates that the natural frequencies of the global modes can exhibit as much as 1% variation within a day. The modal amplitudes of each mode as well as the modal deflection at each measurement position vary insignificantly. The damping ratios however are sensitive to the vibration intensity, especially when the deck vibration exceeds a certain level. Copyright © 2002 John Wiley & Sons, Ltd.  相似文献   

17.
A procedure which involves a non‐linear eigenvalue problem and is based on the substructure method is proposed for the free‐vibration analysis of a soil–structure system. In this procedure, the structure is modelled by the standard finite element method, while the unbounded soil is modelled by the scaled boundary finite element method. The fundamental frequency, and the corresponding radiation damping ratio as well as the modal shape are obtained by using inverse iteration. The free vibration of a dam–foundation system, a hemispherical cavity and a hemispherical deposit are analysed in detail. The numerical results are compared with available results and are also verified by the Fourier transform of the impulsive response calculated in the time domain by the three‐dimensional soil–structure–wave interaction analysis procedure proposed in our previous paper. The fundamental frequency obtained by the present procedure is very close to that obtained by Touhei and Ohmachi, but the damping ratio and the imaginary part of modal shape are significantly different due to the different definition of damping ratio. This study shows that although the classical mode‐superposition method is not applicable to a soil–structure system due to the frequency dependence of the radiation damping, it is still of interest in earthquake engineering to evaluate the fundamental frequency and the corresponding radiation damping ratio of the soil–structure system. Copyright © 2001 John Wiley & Sons, Ltd.  相似文献   

18.
This paper presents an efficient procedure to determine the natural frequencies, modal damping ratios and mode shapes for torsionally coupled shear buildings using earthquake response records. It is shown that the responses recorded at the top and first floor levels are sufficient to identify the dominant modal properties of a multistoried torsionally coupled shear building with uniform mass and constant eccentricity even when the input excitation is not known. The procedure applies eigenrealization algorithm to generate the state‐space model of the structure using the cross‐correlations among the measured responses. The dynamic characteristics of the structure are determined from the state‐space realization matrices. Since the mode shapes are obtained only at the instrumented floor (top and first floors) levels, a new mode shape interpolation technique has been proposed to estimate the mode shape coefficients at the remaining floor levels. The application of the procedure has been demonstrated through a numerical experiment on an eight‐storied torsionally coupled shear building subjected to earthquake base excitation. The results show that the proposed parameter identification technique is capable of identifying dominant modal parameters and responses even with significant noise contamination of the response records. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

19.
Incremental dynamic analysis (IDA)—a procedure developed for accurate estimation of seismic demand and capacity of structures—requires non‐linear response history analysis of the structure for an ensemble of ground motions, each scaled to many intensity levels, selected to cover the entire range of structural response—all the way from elastic behaviour to global dynamic instability. Recognizing that IDA of practical structures is computationally extremely demanding, an approximate procedure based on the modal pushover analysis procedure is developed. Presented are the IDA curves and limit state capacities for the SAC‐Los Angeles 3‐, 9‐, and 20‐storey buildings computed by the exact and approximate procedures for an ensemble of 20 ground motions. These results demonstrate that the MPA‐based approximate procedure reduces the computational effort by a factor of 30 (for the 9‐storey building), at the same time providing results to a useful degree of accuracy over the entire range of responses—all the way from elastic behaviour to global dynamic instability—provided a proper hysteretic model is selected for modal SDF systems. The accuracy of the approximate procedure does not deteriorate for 9‐ and 20‐storey buildings, although their dynamics is more complex, involving several ‘modes’ of vibration. For all three buildings, the accuracy of the MPA‐based approximate procedure is also satisfactory for estimating the structural capacities for the limit states of immediate occupancy, collapse prevention, and global dynamic instability. Copyright © 2006 John Wiley & Sons, Ltd.  相似文献   

20.
The performance of a building under wind and seismic loads depends on stiffness and mass distribution, and may be estimated using finite element codes. Experience has, however, shown that such finite element models often fail to predict accurately the fundamental natural frequencies. Usually the frequencies will be underestimated, that is the building will turn out to be stiffer than anticipated, meaning the design would usually be conservative. On the other hand, effects like torsional eccentricity and foundation compliance may not be correctly modelled, which could be less desirable. A full understanding of linear performance under lateral loads can be obtained through experimental evaluation of the vibration modes. Traditionally only a limited range of modal analysis procedures and software has been applied to civil applications and the ‘special case’ where no input forces can be measured has been the usual situation for large civil structures. Recent developments in system identification, which is the set of procedures to build mathematical models of the dynamic structural systems based on measured data, have added significantly to the potential of ambient vibration or ‘output only’ testing. The aim of the research reported here has been to apply and evaluate the procedures on typical buildings. The procedures are briefly explained and two experimental programmes are then described; a long‐term tremor monitoring exercise on a 280m office tower and an ambient vibration survey of a smaller office block. The different forms of response data are examined to study the performance of the analysis procedures and expose benefits and limitations in their use. There is a growing interest in output‐only modal analysis procedures in civil engineering. The experience reported in this paper has shown that quick and reliable estimation of mode shapes and frequencies can be obtained, even with small amounts of data. Judgement of modal participation and damping ratios requires more detailed study yet the results are at least as convincing as existing and relatively limited frequency domain methods. Copyright © 2002 John Wiley & Sons, Ltd.  相似文献   