首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 109 毫秒
1.
Multiple Tuned Mass Dampers (MTMD's) consisting of many tuned mass dampers (TMD's) with distributed natural frequencies are considered for suppressing effectively the harmonically forced single mode response of structures. The fundamental characteristics of MTMD's are investigated analytically with the parameters of the covering frequency range of MTMD's, the damping ratio of each TMD and the total number of TMD's. The effectiveness and the robustness of MTMD's are also discussed in comparison with those of the usual single TMD. It is found that there exists an optimum MTMD for the given total number of TMD's with the optimum frequency range and the optimum damping ratio and that the optimum MTMD is more effective than the optimum single TMD. As for the robustness, it is also clarified that a MTMD can be much more robust than a single TMD while keeping the same level of effectiveness as the optimum single TMD.  相似文献   

2.
The five MTMD models, with natural frequencies being uniformly distributed around their mean frequency, have been recently presented by the first author. They are shown to have the near‐zero optimum average damping ratio (more precisely, for a given mass ratio there is an upper limit on the total number, beyond which the near‐zero optimum average damping ratio occurs). In this paper, the eight new MTMD models (i.e. the UM‐MTMD1~UM‐MTMD3, US‐MTMD1~US‐MTMD3, UD‐MTMD1 and UD‐MTMD2), with the system parameters (mass, stiffness and damping coefficient) being, respectively, uniformly distributed around their average values, have been, for the first time here, proposed to seek for the MTMD models without the near‐zero optimum average damping ratio. The structure is represented by the mode‐generalized system corresponding to the specific vibration mode that needs to be controlled. Through minimization of the minimum values of the maximum dynamic magnification factors (DMF) of the structure with the eight MTMD models (i.e. through the implementation of Min.Min.Max.DMF), the optimum parameters and values of Min.Min.Max.DMF for these eight MTMD models are investigated to evaluate and compare their control performance. The optimum parameters include the optimum mass spacing, stiffness spacing, damping coefficient spacing, frequency spacing, average damping ratio and tuning frequency ratio. The six MTMD models without the near‐zero optimum average damping ratio (i.e. the UM‐MTMD1~UM‐MTMD3, US‐MTMD1, US‐MTMD2 and UD‐MTMD2) are found through extensive numerical analyses. Likewise, the optimum UM‐MTMD3 offers the higher effectiveness and robustness and requires the smaller damping with respect to the rest of the MTMD models in reducing the responses of structures subjected to earthquakes. Additionally, it is interesting to note, by comparing the optimum UM‐MTMD3 with the optimum MTMD‐1 recently investigated by the first author, that the effectiveness and robustness for the optimum UM‐MTMD3 is almost identical to that for the optimum MTMD‐1 (without inclusion of the optimum MTMD‐1 with the near‐zero optimum average damping ratio). Recognizing these performance benefits, it is preferable to employ the optimum UM‐MTMD3 or the optimum MTMD‐1 without the near‐zero optimum average damping ratio, when installing the MTMD for the suppression of undesirable oscillations of structures under earthquakes. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

3.
Multiple tuned mass dampers (MTMD) consisting of many tuned mass dampers (TMDs) with a uniform distribution of natural frequencies are taken into consideration for attenuating undesirable vibration of a structure under the ground acceleration. A study is conducted to search for the preferable MTMD which performs better and is easily manufactured from the five available models (i.e. MTMD‐1 – MTMD‐5), which comprise various combinations of the stiffness, mass, damping coefficient and damping ratio in the MTMD. The major objective of the present study then is to evaluate and compare the control performance of these five models. The structure is represented by its mode‐generalized system in the specific vibration mode being controlled by adopting the mode reduced‐order approach. The optimum parameters of the MTMD‐1 – MTMD‐5 are investigated to reveal the influence of the important parameters on their effectiveness and robustness using a numerical searching technique. The parameters include the frequency spacing, average damping ratio, tuning frequency ratio, mass ratio and total number. The criteria selected for the optimum searching are the minimization of the maximum value of the displacement dynamic magnification factor (DDMF) and that of the acceleration dynamic magnification factor (ADMF) of the structure with the MTMD‐1 – MTMD‐5 (i.e. Min.Max.DDMF and Min.Max.ADMF). It is demonstrated that the optimum MTMD‐1 and MTMD‐4 yield approximately the same control performance, and offer higher effectiveness and robustness than the optimum MTMD‐2, MTMD‐3, and MTMD‐5 in reducing the displacement and acceleration responses of structures. It is further demonstrated that for both the best effectiveness and robustness and the simplest manufacturing, it is preferable to select the optimum MTMD‐1. Copyright © 2002 John Wiley & Sons, Ltd.  相似文献   

4.
Passive and semi‐active tuned mass damper (PTMD and SATMD) building systems are proposed to mitigate structural response due to seismic loads. The structure's upper portion self plays a role either as a tuned mass passive damper or a semi‐active resetable device is adopted as a control feature for the PTMD, creating a SATMD system. Two‐degree‐of‐freedom analytical studies are employed to design the prototype structural system, specify its element characteristics and effectiveness for seismic responses, including defining the resetable device dynamics. The optimal parameters are derived for the large mass ratio by numerical analysis. For the SATMD building system the stiffness of the resetable device design is combined with rubber bearing stiffness. From parametric studies, effective practical control schemes can be derived for the SATMD system. To verify the principal efficacy of the conceptual system, the controlled system response is compared with the response spectrum of the earthquake suites used. The control ability of the SATMD scheme is compared with that of an uncontrolled (No TMD) and an ideal PTMD building systems for multi‐level seismic intensity. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

5.
The steady‐forced and earthquake responses of SDF systems with a non‐linear fluid viscous damper (FVD) are investigated. The energy dissipation capacity of the FVD is characterized by the supplemental damping ratio ζsd and its non‐linearity by a parameter designated α. It is found that the structural response is most effectively investigated in terms of ζsd and α because (1) these two parameters are dimensionless and independent, and (2) the structural response varies linearly with the excitation intensity. Damper non‐linearity has essentially no influence on the peak response of systems in the velocity‐sensitive spectral region, but differences up to 14% were observed in the other spectral regions. The structural deformation is reduced by up to 25% when ζsd= 5%; and by up to 60% when ζsd= 30%. Non‐linear FVDs are advantageous because they achieve essentially the same reduction in system responses but with a significantly reduced damper force. For practical applications, a procedure is presented to estimate the design values of structural deformation and forces for a system with non‐linear FVD directly from the design spectrum. It is demonstrated that the earthquake‐induced force in a non‐linear FVD can be estimated from the damper force in a corresponding system with linear FVD, its peak deformation, and peak relative velocity; however, the relative velocity should not be approximated by the pseudo‐velocity as this approximation introduces a large error in the damper force. Finally, a procedure is presented to determine the non‐linear damper properties necessary to limit the structural deformation to some design value or the structural capacity for a given design spectrum. Copyright © 2002 John Wiley & Sons, Ltd.  相似文献   

6.
This study proposes a new design method for an active mass damper (AMD) that is based on auto‐regressive exogenous models of a building structure. The proposed method uses the results of system identification in the field of active structural control. The uncontrolled structure is identified as auto‐regressive exogenous models via measurements under earthquake excitation and forced vibration. These models are linked with an equation of motion for the AMD to introduce a state equation and output equation for the AMD–structure interaction system in the discrete‐time space; the equations apply modern control theories to the AMD design. In the numerical applications of a 10‐degree‐of‐freedom building structure, linear quadratic regulator control is used to understand the fundamental characteristics of the proposed design procedure. The feedback control law requires the AMD's acceleration, velocity and stroke; the structure's acceleration; and the ground acceleration as vibration measurements. The numerical examples confirm the high applicability and control effectiveness of the proposed method. One remarkable advantage of the proposed method is that an equation of motion for the structure becomes unnecessary for designing controllers. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

7.
Multiple tuned mass dampers (MTMDs) consisting of many tuned mass dampers (TMDs) with a uniform distribution of natural frequencies are considered for attenuating undesirable vibration of a structure. The MTMD is manufactured by keeping the stiffness and damping constant and varying the mass. The structure is represented by its mode‐generalized system in the specific vibration mode being controlled using the mode reduced‐order method. The optimum parameters of the MTMD are investigated to delineate the influence of the important parameters on the effectiveness and robustness of the MTMD by conducting a numerical searching technique in two directions. The parameters include: the frequency spacing, average damping ratio, mass ratio and total number. The criterion selected for the optimization is the minimization of the maximum value of the dynamic magnification factor (DMF) of the structure with MTMD (i.e. Min.Max.DMF). In this paper, for the sake of comparison, the MTMD(II), which is made by keeping the mass constant and varying the stiffness and damping coefficient, and a single TMD are also taken into account. It is demonstrated that the optimum frequency spacing of the MTMD is the same as that of the MTMD(II) and the optimum average damping ratio of the MTMD is a little larger than that of the MTMD(II). It is also found that the optimum MTMD is more effective than the optimum MTMD(II) and the optimum single TMD with equal mass. Copyright © 2000 John Wiley & Sons, Ltd.  相似文献   

8.
Porcelain electrical equipment (PEE), such as current transformers, is critical to power supply systems, but its seismic performance during past earthquakes has not been satisfactory. This paper studies the seismic performance of two typical types of PEE and proposes a damping method for PEE based on multiple tuned mass dampers (MTMD). An MTMD damping device involving three mass units, named a triple tuned mass damper (TTMD), is designed and manufactured. Through shake table tests and finite element analysis, the dynamic characteristics of the PEE are studied and the effectiveness of the MTMD damping method is verified. The adverse influence of MTMD redundant mass to damping efficiency is studied and relevant equations are derived. MTMD robustness is verified through adjusting TTMD control frequencies. The damping effectiveness of TTMD, when the peak ground acceleration far exceeds the design value, is studied. Both shake table tests and finite element analysis indicate that MTMD is effective and robust in attenuating PEE seismic responses. TTMD remains effective when the PGA far exceeds the design value and when control deviations are considered.  相似文献   

9.
The authors developed a semi‐active hydraulic damper (SHD) and installed it in an actual building in 1998. This was the first application of a semi‐active structural control system that can control a building's response in a large earthquake by continuously changing the device's damping coefficient. A forced vibration test was carried out by an exciter with a maximum force of 100 kN to investigate the building's vibration characteristics and to determine the system's performance. As a result, the primary resonance frequency and the damping ratio of a building that the SHDs were not jointed to, decreased as the exciting force increased due to the influence of non‐linear members such as PC curtain walls. The equivalent damping ratio was estimated by approximating the resonance curves using the steady‐state response of the SDOF bilinear hysteretic system. After the eight SHDs were jointed to the building, the system's performance was identified by a response control test for steady‐state vibration. The elements that composed the semi‐active damper system demonstrated the specified performance and the whole system operated well. Copyright © 2000 John Wiley & Sons, Ltd.  相似文献   

10.
本文研究了土-结构动力相互作用对采取不同控制措施的结构控制效果的影响。文中首先建立了主动调谐质量阻尼器(ATMD)、半主动磁流变阻尼器(MR)和被动多重调谐质量阻尼器(MTMD)等三种结构控制措施在时域中的控制算法和控制律,然后基于子结构法,采用间接边界元方法,通过傅里叶变换,推导了分别安装三种结构控制措施的受控结构在频域中的运动方程,数值仿真分析了某36层高层建筑的地震反应及其控制效果。结果表明,当采用ATMD或MTMD控制时,考虑土-结构动力相互作用后结构地震反应有所减小;当采用MR控制时,考虑土-结构动力相互作用后结构地震反应有很大程度的减小。由此看来,在设计软土地基上高层结构的结构控制措施时,不考虑土-结构动力相互作用对结构控制效果的影响是偏于安全的。  相似文献   

11.
A building with a seismic isolation system, in an earthquake, is recognized as producing substantially smaller accelerations and deformations compared with a building that use other systems. This type of system is therefore expected to better protect the building's nonstructural components, equipment, and other contents that are essential for the activities conducted in the building. Unlike many available studies on building responses, only a small number of studies on a buildings' nonstructural component responses are available, and no study has directly addressed building performance with regard to nonstructural component protection. This paper therefore measures the performance of various seismically isolated buildings. Specifically, the effects of important structural parameters, namely, isolation stiffness, isolation damping ratio, and number of stories on the response of base‐isolated structures are investigated parametrically. Ground motions with 2% exceedence in 50years Maximum Considered Earthquake (MCE) are used. Performance is compared with that of fixed‐base structures in order to present data that will be useful in justifying the more costly technology. The buildings are 3, 9, and 20 stories, represented by MDOF shear‐beam models. As examples of displacement‐sensitive and acceleration‐sensitive components, partition walls and ceilings are considered, respectively. The Pacific Earthquake Engineering Research Center performance‐based earthquake engineering methodology is adopted to evaluate the failure return periods of the examples based on their available fragility curves. In addition, the curves are varied hypothetically to understand the sensitivity of the return period to the curve features. Then, the median and dispersion of fragility curves required to satisfy the components' desired failure return period are obtained. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

12.
The mid‐story isolation design method is recently gaining popularity for the seismic protective design of buildings located in the areas of high population. In a mid‐story isolated building, the isolation system is incorporated into the mid‐story rather than the base of the building. In this paper, the dynamic characteristics and seismic responses of mid‐story isolated buildings are investigated using a simplified three‐lumped‐mass structural model for which equivalent linear properties are formulated. From the parametric study, it is found that the nominal frequencies of the superstructure and the substructure, respectively, above and below the isolation system have significant influences on the isolation frequency and equivalent damping ratio of a mid‐story isolated building. Moreover, the mass and stiffness of the substructure are of greater significance than the superstructure in affecting the dynamic characteristics of the isolated building. Besides, based on the response spectrum analysis, it is noted that the higher mode responses may contribute significantly to the story shear force of the substructure. Consequently, the equivalent lateral force procedure of design codes should carefully include the effects of higher modes. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

13.
This paper presents a procedure for seismic design of reinforced concrete structures, in which performance objectives are formulated in terms of maximum accepted mean annual frequency (MAF) of exceedance, for multiple limit states. The procedure is explicitly probabilistic and uses Cornell's like closed‐form equations for the MAFs. A gradient‐based constrained optimization technique is used for obtaining values of structural design variables (members' section size and reinforcement) satisfying multiple objectives in terms of risk levels. The method is practically feasible even for real‐sized structures thanks to the adoption of adaptive equivalent linear models where element‐by‐element stiffness reduction is performed (2 linear analyses per intensity level). General geometric and capacity design constraints are duly accounted for. The procedure is applied to a 15‐storey plane frame building, and validation is conducted against results in terms of drift profiles and MAF of exceedance, obtained by multiple‐stripe analysis with records selected to match conditional spectra. Results show that the method is suitable for performance‐based seismic design of RC structures with explicit targets in terms of desired risk levels.  相似文献   

14.
This paper discusses an analytical study that quantifies the expected earthquake‐induced losses in typical office steel frame buildings designed with perimeter special moment frames in highly seismic regions. It is shown that for seismic events associated with low probabilities of occurrence, losses due to demolition and collapse may be significantly overestimated when the expected loss computations are based on analytical models that ignore the composite beam effects and the interior gravity framing system of a steel frame building. For frequently occurring seismic events building losses are dominated by non‐structural content repairs. In this case, the choice of the analytical model representation of the steel frame building becomes less important. Losses due to demolition and collapse in steel frame buildings with special moment frames designed with strong‐column/weak‐beam ratio larger than 2.0 are reduced by a factor of two compared with those in the same frames designed with a strong‐column/weak‐beam ratio larger than 1.0 as recommended in ANSI/AISC‐341‐10. The expected annual losses (EALs) of steel frame buildings with SMFs vary from 0.38% to 0.74% over the building life expectancy. The EALs are dominated by repairs of acceleration‐sensitive non‐structural content followed by repairs of drift‐sensitive non‐structural components. It is found that the effect of strong‐column/weak‐beam ratio on EALs is negligible. This is not the case when the present value of life‐cycle costs is selected as a loss‐metric. It is advisable to employ a combination of loss‐metrics to assess the earthquake‐induced losses in steel frame buildings with special moment frames depending on the seismic performance level of interest. Copyright © 2017 John Wiley & Sons, Ltd.  相似文献   

15.
This paper presents an application of multiple tuned mass dampers (MTMDs) with non‐linear damping devices to suppress man‐induced vibrations of a 34m long pedestrian bridge. The damping force generated by each of these damping devices is simply a drag force from liquid acting on an immersed section. The quadratic non‐linear property of these devices was directly determined from free vibration tests of a simple laboratory set‐up. Dynamic models of the bridge and pedestrian loads were constructed for numerical investigation based on field measurement data. The control effectiveness of non‐linear MTMDs was examined along with its sensitivity against estimation errors in the bridge's natural frequency and magnitude of pedestrian load. The numerical results indicated that the optimum non‐linear MTMD system was as effective and robust as its linear counterpart. Then, a six‐unit non‐linear MTMD system was designed, constructed, and installed on the bridge. Field measurements after the installation confirmed the effectiveness of non‐linear MTMDs, and the measurement results were in good agreement with numerical predictions. After the installation, the average damping ratio of the bridge was raised from 0.005 to 0.036 and the maximum bridge accelerations measured during walking tests were reduced from about 0.80–1.30 ms?2 to 0.27–0.40 ms?2, which were within an acceptable range. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

16.
Numerical simulations of a single‐degree‐of‐freedom (SDOF) structure, rigidly supporting a tuned liquid damper (TLD) and subjected to both real and artificially generated earthquake ground motions, show that a properly designed TLD can significantly reduce the structure's response to these motions. The TLD is a rigid, rectangular tank with shallow water in it. Its fundamental linear sloshing frequency is tuned to the structure's natural frequency. The TLD is more effective in reducing structural response as the ground excitation level increases. This is because it then dissipates more energy due to sloshing and wave breaking. A larger water‐depth to tank‐length ratio than previous studies suggested, which still falls within the constraint of shallow water theory, is shown to be more suitable for excitation levels expected in strong earthquake motions. A larger water‐mass to structure‐mass ratio is shown to be required for a TLD to remain equally effective as structural damping increases. Furthermore, the reduction in response is seen to be fairly insensitive to the bandwidth of the ground motion but is dependent on the structure's natural frequency relative to the significant ground frequencies. Finally, a practical approach is suggested for the design of a TLD to control earthquake response. Copyright © 2000 John Wiley & Sons, Ltd.  相似文献   

17.
The height of 101‐storey Shanghai World Financial Center Tower is 492m above ground making it possible the tallest building in the world when completed. Three parallel structural systems including mega‐frame structure, reinforced concrete and braced steel services core and outrigger trusses, are combined to resist vertical and lateral loads. The building could be classified as a vertically irregular structure due to a number of stiffened and transfer stories in the building. Complexities related to structural system layout are mainly exhibited in the design of services core, mega‐diagonals and outrigger trusses. According to Chinese Code, the height 190 m of the building clearly exceeds the stipulated maximum height of for a composite frame/reinforced concrete core building. The aspect ratio of height to width also exceeds the stipulated limit of 7 for seismic design intensity 7. A 1/50 scaled model is made and tested on shaking table under a series of one and two‐dimensional base excitations with gradually increasing acceleration amplitudes. This paper presents the dynamic characteristics, the seismic responses and the failure mechanism of the structure. The test results demonstrate that the structural system is a good solution to withstand earthquakes. The inter‐storey drift and the overall behaviour meet the requirements of Chinese Design Code. Furthermore, weak positions under seldom‐occurred earthquakes of seismic design intensity 8 are found based on the visible damages on the testing model, and some corresponding suggestions are proposed for the engineering design of the structure under extremely strong earthquake. Copyright © 2006 John Wiley & Sons, Ltd.  相似文献   

18.
The aim of this work is to propose seismic reliability‐based relationships between the strength reduction factors and the displacement ductility demand of nonlinear structural systems equipped with friction pendulum isolators (FPS) depending on the structural properties. The isolated structures are described by employing an equivalent 2dof model characterized by a perfectly elastoplastic rule to account for the inelastic response of the superstructure, whereas, the FPS behavior is described by a velocity‐dependent model. An extensive parametric study is carried out encompassing a wide range of elastic and inelastic building properties, different seismic intensity levels and considering the friction coefficient as a random variable. Defined a set of natural seismic records and scaled to the seismic intensity corresponding to life safety limit state for L'Aquila site (Italy) according to NTC08, the inelastic characteristics of the superstructures are designed as the ratio between the average elastic responses and increasing strength reduction factors. Incremental dynamic analyses (IDAs) are developed to evaluate the seismic fragility curves of both the inelastic superstructure and the isolation level assuming different values of the corresponding limit states. Integrating the fragility curves with the seismic hazard curves related to L'Aquila site (Italy), the reliability curves of the equivalent inelastic base‐isolated structural systems, with a design life of 50 years, are derived proposing seismic reliability‐based regression expressions between the displacement ductility demand and the strength reduction factors for the superstructure as well as seismic reliability‐based design (SRBD) abacuses useful to define the FPS properties. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

19.
Dynamic characteristics of structures — viz. natural frequencies, damping ratios, and mode shapes — are central to earthquake‐resistant design. These values identified from field measurements are useful for model validation and health‐monitoring. Most system identification methods require input excitations motions to be measured and the structural response; however, the true input motions are seldom recordable. For example, when soil–structure interaction effects are non‐negligible, neither the free‐field motions nor the recorded responses of the foundations may be assumed as ‘input’. Even in the absence of soil–structure interaction, in many instances, the foundation responses are not recorded (or are recorded with a low signal‐to‐noise ratio). Unfortunately, existing output‐only methods are limited to free vibration data, or weak stationary ambient excitations. However, it is well‐known that the dynamic characteristics of most civil structures are amplitude‐dependent; thus, parameters identified from low‐amplitude responses do not match well with those from strong excitations, which arguably are more pertinent to seismic design. In this study, we present a new identification method through which a structure's dynamic characteristics can be extracted using only seismic response (output) signals. In this method, first, the response signals’ spatial time‐frequency distributions are used for blindly identifying the classical mode shapes and the modal coordinate signals. Second, cross‐relations among the modal coordinates are employed to determine the system's natural frequencies and damping ratios on the premise of linear behavior for the system. We use simulated (but realistic) data to verify the method, and also apply it to a real‐life data set to demonstrate its utility. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

20.
The increasing strength of new structural materials and the span of new structures,accompanied by aesthetic requirements for greater slenderness,are resulting in more applications of long-span structures.In this paper,serviceability control technology and its design theory are studied.First,a novel tuned mass damper(TMD)with controllable stiffness is developed.Second,methods for modeling human-induced loads are proposed,including standing up,walking,jumping and running,and an analysis method for long-span floor response is proposed based on a finite element model.Third,a design method for long-span floors installed with a multiple TMD(MTMD)system considering human comfort is introduced, largely based on a study of existing literature.Finally,a design,analysis and field test is conducted using several large scale buildings in China including the Beijing Olympic Park National Conference Center,Changsha New Railway Station and the Xi’an Northern Railway Station.The analytical and field test results show that the MTMD system designed using the proposed method is capable of effectively mitigating the vertical vibration of long-span floor structures.The study presented in this paper provides an important reference for the analysis of vibration serviceability of similar long-span floors and design of control system for these structures.  相似文献   